- Tytuł:
- Biomechanical Analysis of Two-Point Asymmetric Screw Fixation with Implant for Femoral Neck Fracture
- Autorzy:
-
Karev, B. D.
Barsukov, V. G. - Powiązania:
- https://bibliotekanauki.pl/articles/386812.pdf
- Data publikacji:
- 2012
- Wydawca:
- Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
- Tematy:
-
pęknięcie kości
mocowanie śrubowe
kość korowa
kość beleczkowa
femoral neck fracture
screw fixation
stressed state
cortical bone
trabecular bone - Opis:
- Stressed state peculiarities of cortical and trabecular bones by two,point asymmetric screw fixation with implant for femoral neck fracture are studied. Layer construction mechanic methods are used for analysis of stresses in cortical and trabecular bones. Biomechanical conditions for non,opening of the junction of the bone parts being joined are determined. It has been found that the total tightness of the broken parts when they rest against each other is secured over the whole fracture section without junction opening under condition that fixing screws are positioned in the trabecular bone without penetration of the thread side surface into cortical bone.
- Źródło:
-
Acta Mechanica et Automatica; 2012, 6, 4; 19-22
1898-4088
2300-5319 - Pojawia się w:
- Acta Mechanica et Automatica
- Dostawca treści:
- Biblioteka Nauki