Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stosunek wodno-cementowy" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Impact of moisture conditions on early shrinkage of ordinary concrete with changing w/c ratio
Autorzy:
Jasiczak, J.
Szymański, P.
Nowotarski, P.
Powiązania:
https://bibliotekanauki.pl/articles/230652.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton zwykły
skurcz betonu
warunki wilgotnościowe
stosunek wodno-cementowy
skurcz schnięcia
ordinary concrete
concrete shrinkage
moisture conditions
w/c ratio
drying shrinkage
Opis:
Article presents the results of the effect of humidity on early shrinkage of normal concrete with variable W/C ratio. As known for a long time, shrinkage is dependent of many factors. One of them is the W/C ratio and the quantity of water which is located in the concrete mix. In article there were discussed changes taking place in the concrete mix, the methods of research and the partial results obtained by the authors of the paper. Shrinkage is a phenomenon well known and studied by various research centers. The total amount of shrinkage may depend on various factors such as humidity, temperature, composition of the concrete mix, the W/C ratio, the size of the item. The study was conducted to determine the amount of shrinkage in its early stages. It is very important for concrete floors contractors, precast manufacturers to start at the right time finishing work and prevent the formation of shrinkage cracks.
Źródło:
Archives of Civil Engineering; 2014, 60, 2; 241-256
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An investigation of mechanical properties of recycled coarse aggregate concrete
Badania właściwości mechanicznych betonu kruszywowego wtórnego wykonanego z użyciem kruszywa gruboziarnistego także pochodzenia wtórnego
Autorzy:
Deng, X. H.
Lu, Z. L.
Li, P.
Xu, T.
Powiązania:
https://bibliotekanauki.pl/articles/962346.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
kruszywo gruboziarniste
kruszywo z recyklingu
stosunek wodno-cementowy
wskaźnik zamiany
wytrzymałość na ściskanie
wytrzymałość na rozciąganie
rozłupywanie
concrete
coarse aggregate
recycled aggregate
water-cement ratio
replacement rate
compression strength
tensile strength
splitting
Opis:
Recycling construction and demolition waste not only reduces project costs; and saves natural resources, but also solves the environmental threat caused by construction waste disposal. In this paper, C25 waste road concrete is used as an experimental material, the uniaxial compression strength and tensile splitting strength of C25 RAC whose coarse aggregate replacement rate is 0%, 25%, 50%, 75%, and 100% are tested under the condition that the water-to-cement ratio is 0.47, 0.55 and 0.61. The results show: (1) the uniaxial compression strength and tensile splitting strength decrease with the increase of RAC; (2) for concrete with the same water-to-cement ratio, when the coarse aggregate replacement rate changes from 0% to 50%, the uniaxial compression strength and tensile splitting strength of RAC changes slightly. When the coarse aggregate replacement rate changes from 50% to 100%, the uniaxial compression strength and tensile splitting strength of RAC decreases rapidly.
Recykling odpadów budowlanych oraz materiałów pochodzących z rozbiórek nie tylko zmniejsza koszty projektu i oszczędza zasoby naturalne, ale również zażegnuje zagrożenie dla środowiska spowodowane przez składowanie odpadów budowlanych. Szczególnie w odniesieniu do właściwości mechanicznych betonu z kruszywa gruboziarnistego poddanego recyklingowi, odpady betonu drogowego C25 są używane jako materiał eksperymentalny, pod warunkiem że stosunek wody do cementu wynosi 0,47, 0,55 i 0,61 oraz są przygotowane próbki betonu o wskaźniku zamiany betonu z kruszywa gruboziarnistego poddawanego recyklingowi wynoszącym 25%, 50%, 75% i 100% betonu z naturalnego kruszywa gruboziarnistego. Próbka to sześcian o wymiarach 150 × 150 × 150 mm. Przygotowaliśmy 6 próbek dla każdego wskaźnika zamiany betonu z kruszywa gruboziarnistego poddawanego recyklingowi. Przygotowano łącznie 90 próbek betonu. Próbki zostały usunięte 24 godziny po ustawieniu oraz były utwardzane w temperaturze 20°C i wilgotności 90% przez 28 dni. Następnie przeprowadzono próby ściskania jednoosiowego oraz wytrzymałości na rozciąganie przez rozłupywanie betonu z kruszywa poddawanego recyklingowi C25.
Źródło:
Archives of Civil Engineering; 2016, 62, 4/II; 19-34
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies