Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "steel column" wg kryterium: Temat


Tytuł:
Behavior of RC columns strengthened with steel jacket under static axial load
Autorzy:
Ghoneim, Abd Rahman Mujahid Ahmed
Mohamed, Mohamed Mahmoud Ahmed
Haridy, Kader
Ahmed, Hazem
Pyram, Mohmmad
Khalf, Abdu
Powiązania:
https://bibliotekanauki.pl/articles/27312173.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
słup żelbetowy
wzmacnianie
utwierdzenie
kątownik stalowy
taśma stalowa
reinforced concrete column
strengthening
confinement
steel angle
steel strip
Opis:
The column is one of the most significant structural elements, which is designed to support mainly the compressive load. Strengthening of existing reinforced concrete columns is required to enhance ductility and increase load capacity to sustain the overload as sometimes there may be a change in use. Ten rectangular concrete columns were constructed and tested. H/b ratio was kept constant and equals 6 for all columns. The aim of this work is to study the behaviour and efficiency of RC columns strengthened with steel jackets subjected to axial load. An experimental study of the behaviour of ten strengthened concrete columns with slenderness ratio (H/b) equals 6 was carried out. Variables such as aspect ratio (t/b), the volume of steel batten plates, and spacing of steel batten plates at centres (S) were considered. The results showed that using this method of strengthening is very effective and an increase in the axial load capacity of the strengthened columns is obtained.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 367--379
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation of steel frame robustness under external sudden column removal
Numeryczna analiza odporności ram stalowych pod nagłym usuwaniem słupa zewnętrznego
Autorzy:
Kozłowski, Aleksander
Kukla, Damian
Powiązania:
https://bibliotekanauki.pl/articles/27312138.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
analiza dynamiczna
konstrukcja ramowa
usunięcie słupa
ocena odporności
połączenie śrubowe stalowe
słup zewnętrzny
dynamic analysis
external column
column loss
framed structure
robustness assessment
steel bolted joint
Opis:
Numerical analysis of robustness assessment of steel planar framed structures under sudden external column removal is presented. The analysis is based on the previous experimental and numerical analyzes conducted in the Ph.D. project. Advanced and validated finite element models of steel structures with bolted end plate joints were used using Abaqus software. Six different cases of analysis using flush and extended bolted end-plate joints were performed. The actual results of the axial forces and rotations of the joints, failure models, and other important factors about structure behaviour are presented. The clear division of the results obtained depended on the type of joint used in the structure. In the cases of application of extended end-plate joints in frame analysis, the required level of robustness was reached in all cases and stopping of collapse development was obtained. In all cases of frame analysis with flush end-plate joints, an insufficient level of robustness on progressive collapse was obtained and partial failures of the structures were reached. Due to the location of the external column, the catenary actions to mitigate progressive collapse were very limited.
Przedstawiono analizę numeryczną oceny odporności stalowych płaskich konstrukcji ramowych pod wpływem nagłego usunięcia słupa zewnętrznego. Przeprowadzono analizy w oparciu o wcześniejsze badania eksperymentalne i analizy numeryczne przeprowadzone w ramach pracy doktorskiej pierwszego autora. Wykorzystano zaawansowane i zwalidowane modele elementów skończonych konstrukcji stalowej z połączeniami śrubowymi z blachą czołową przy użyciu oprogramowania Abaqus. Przeprowadzono sześć różnych przypadków analizy, w których zastosowano połączenia śrubowe doczołowe z blachą wpuszczoną i wystającą. Przedstawiono dokładne wyniki sił osiowych i obrotów połączeń, modele zniszczenia i inne ważne czynniki dotyczące zachowania konstrukcji. Wyraźny podział otrzymanych wyników zależny jest od rodzaju zastosowanego węzła w konstrukcji. W przypadku zastosowania w analizie ram połączeń doczołowych z blachą wystającą, we wszystkich przypadkach osiągnięto wymagany poziom odporności i zatrzymano rozwój katastrofy. We wszystkich przypadkach analizy ram z połączeniami doczołowymi z blachą wpuszczoną uzyskano niewystarczający poziom odporności na postępującą katastrofę i obserwowano częściowe uszkodzenia konstrukcji. Ze względu na usytuowanie słupa zewnętrznego działanie akcji cięgnowej mające na celu złagodzenie postępującego zawalenia było znacznie ograniczone. Na koniec przedstawiono zalecenia dotyczące kształtowania doczołowych połączeń śrubowych w celu zwiększenia odporności konstrukcji.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 177--193
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Refined energy method for the elastic flexural-torsional buckling of steel H-section beam-columns. Part II: Comparison and verification for elements LTU and LTR
Udoskonalona metoda energetyczna sprężystego wyboczenia giętno-skrętnego stalowych elementów ściskanych i zginanych o przekroju dwuteowym. Część II: Porównanie i weryfikacja dla elementów LTU i LTR
Autorzy:
Giżejowski, Marian
Barszcz, Anna
Wiedro, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/27312074.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
element stalowy
ściskanie ze zginaniem
dwuteownik bisymetryczny
zachowanie sprężyste
wyboczenie giętno-skrętne
symulacja numeryczna
weryfikacja
rozwiązanie analityczne
steel beam-column
bisymmetric cross-section
double T section
elastic behaviour
flexural-torsional buckling
numerical simulation
verification
analytical solutions
Opis:
In investigations constituting Part I of this paper, the effect of approximations in the flexural-torsional buckling analysis of beam-columns was studied. The starting point was the formulation of displacement field relationships built straightforward in the deflected configuration. It was shown that the second-order rotation matrix obtained with keeping the trigonometric functions of the mean twist rotation was sufficiently accurate for the flexural-torsional stability analysis. Furthermore, Part I was devoted to the formulation of a general energy equation for FTB being expressed in terms of prebuckling stress resultants and in-plane deflections through the factor k1. The energy equation developed there was presented in several variants dependent upon simplified assumptions one may adopt for the buckling analysis, i.e. the classical form of linear eigenproblem analysis (LEA), the form of quadratic eigenproblem analysis (QEA) and refined (non-classical) forms of nonlinear eigenproblem analysis (NEA), all of them used for solving the flexural-torsional buckling problems of elastic beam-columns. The accuracy of obtained analytical solutions based on different approximations in the elastic flexural-torsional stability analysis of thin-walled beam-columns is examined and discussed in reference to those of earlier studies. The comparison is made for closed form solutions obtained in a companion paper, with a scatter of results evaluated for k1 = 1 in the solutions of LEA and QEA, as well as for all the options corresponding to NEA. The most reliable analytical solution is recommended for further investigations. The solutions for selected asymmetric loading cases of the left support moment and the half-length uniformly distributed span load of a slender unrestrained beam-column are discussed in detail in Part II. Moreover, the paper constituting Part II investigates how the buckling criterion obtained for the beam-column laterally and torsionally unrestrained between the end sections might be applied for the member with discrete restraints. The recommended analytical solutions are verified with use of numerical finite element method results, considering beam-columns with a mid-section restraint. A variant of the analytical form of solutions recommended in these investigations may be used in practical application in the Eurocode’s General Method of modern design procedures for steelwork.
W I części niniejszej pracy zastosowano różne rodzaje aproksymacji w analizie wyboczenia giętno-skrętnego elementów ściskanych i zginanych w płaszczyźnie większej bezwładności przekroju. Punktem wyjścia było sformułowanie zależności na pole przemieszczeń w konfiguracji odkształconej. Pokazano, że macierz rotacji, otrzymana przy zachowaniu funkcji trygonometrycznych średniego kąta skręcenia, jest wystarczająco dokładna do analizy stateczności giętno-skrętnej. Szczególną uwagę zwrócono w Części I na sformułowanie ogólnego równania energetycznego dla FTB, wyrażonego w funkcji sił przekrojowych na podstawowej ścieżce równowagi, przed utratą płaskiej postaci zginania II rzędu, a także wpływu efektu ugięć w płaszczyźnie większej bezwładności przekroju, wyrażonego za pomocą współczynnika k1. Otrzymane równanie energetyczne zostało przedstawione w kilku wariantach zależnych od założeń upraszczających, jakie można przyjąć do rozwiązywania problemów wyboczenia giętno-skrętnego, tj. w postaci klasycznej analizy liniowego problemu własnego (LEA), w postaci kwadratowego problemu własnego (QEA) oraz w postaci udoskonalonej (nieklasycznej) analizy nieliniowego problemu własnego (NEA). W części II, w pierwszej kolejności, została zbadana i dyskutowana dokładność otrzymanych rozwiązań analitycznych w odniesieniu do propozycji przedstawionych we wcześniejszych opracowaniach. Przeprowadzone są też porównania dla rozwiązań w postaci zamkniętej uzyskanych w Części I, z oceną rozrzutu wyników, po przyjęciu k1 = 1 w rozwiązaniach odpowiadających LEA i QEA, a także wszystkich opcji w rozwiązaniach odpowiadających NEA. Do dalszych badań rekomendowano najbardziej wiarygodne rozwiązanie analityczne. Szczegółowej weryfikacji poddano rozwiązania uzyskane dla wybranych asymetrycznych przypadków obciążenia: momentem na lewej podporze i równomiernie rozłożonym obciążeniem w połowie długości nieusztywnionego, smukłego elementu ściskanego i zginanego. Ponadto w Części II zbadano, w jaki sposób kryterium wyboczeniowe, uzyskane dla elementu ściskanego i zginanego bez usztywnień poprzecznych i przeciwskrętnych między przekrojami końcowymi, może być zastosowane dla elementu z dyskretnymi stężeniami poprzecznymi. Zalecane rozwiązania analityczne zweryfikowano z wykorzystaniem wyników numerycznych metody elementów skończonych dla elementów stężonych w przekroju środkowym. Wariant analitycznej postaci rozwiązania zalecanego w zaprezentowanych badaniach może być wykorzystany w praktyce w eurokodowej Metodzie Ogólnej (GM).
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 265--289
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bond between steel and SCC in completely concrete encased HEA 160 I-section columns
Przyczepność między stałą i betonem SCC w słupach zespolonych o przekroju złożonym z obetonowanego dwuteownika HEA 160
Autorzy:
Szadkowska, Magdalena
Szmigiera, Elżbieta
Powiązania:
https://bibliotekanauki.pl/articles/2174032.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
przekrój dwuteowy
słup zespolony
słup stalowo-betonowy
beton samozagęszczalny
przyczepność
I-section
composite column
steel-concrete column
self-compacting concrete
bond
Opis:
The paper presents research results of bond tests in completely concrete encased steel Isection columns made of self-compacting concrete (SCC). The results of push-out tests obtained by elements made of SCC were compared with those elements, which were made of vibrated concrete. The influence of selected factors on resistance to the vertical shear was considered in this study. The analysis of research results shows that the resistance to the vertical shear between steel I-section and SCC concrete depends on distance between stirrups and concrete age. Shrinkage has important influence on interfacial bond forces. The test results were compared with a recommendations given in the Design code - Eurocode 4. This standard can be used only for composite elements made of lightweight and vibrated concrete. In the case of completely concrete encased I-section composite columns the shear resistance after 28 days and after concrete shrinkage was higher than design resistance strength given in the standard. This means that the design value of the shear strength given in the standard should be verified and checked, if it can be applied to elements made of SCC concrete. Further tests should be carried out to determine the value of shear resistance for such elements.
Stalowo-betonowe słupy o przekroju złożonym z obetonowanego dwuteownika stanowią jeden z podstawowych typów słupów zespolonych szeroko stosowanych w budownictwie. Dzięki takim cechom jak: wysoka nośność, sztywność czy też ciągliwość, zyskały na popularności i znalazły zastosowanie jako podpory w obiektach mostowych, konstrukcjach hydrotechnicznych, a także w różnego rodzaju budynkach posadowionych na terenach zagrożonych sejsmicznie. Przekroje złożone z obetonowanego dwuteownika są powszechnie stosowane, np. w podmorskich tunelach Chin. Jednocześnie istotnym zagadnieniem rozważanym w wielu publikacjach jest możliwość wzmocnienia stalowych, skorodowanych słupów, stanowiących podpory mostów w Stanach Zjednoczonych, poprzez ich obetonowanie. W tego typu konstrukcjach, których przekroje są często gęsto zbrojone, a przestrzeń między deskowaniem i stalowym kształtownikiem nieduża, zasadnym wydaje się użycie betonu samozagęszczalnego (SCC z ang. Self-Compacting Concrete). Dlatego Autorki artykuły podjęły się zbadania przyczepności między stalą i betonem samozagęszczalnym w zespolonych słupach o przekroju złożonym z obetonowanego dwuteownika HEA 160. W niniejszym artykule przedstawiono wyniki badań przyczepności miedzy stalą i betonem samozagęszczalnym (SCC), elementów złożonych z obetonowanego dwuteownika HEA 160 i porównano je z wynikami uzyskanymi przez elementy wykonane z betonu wibrowanego. W pracy przedstawiono również wpływ wybranych czynników na nośność na ścinanie w płaszczyźnie zespolenia. Analiza wyników badań pokazała, że rozstaw zbrojenia poprzecznego oraz wiek i rodzaj betonu wpływają na nośność na ścinanie w płaszczyźnie zespolenia. Jednocześnie wyniki badań obliczeniowej nośności na ścinanie w płaszczyźnie zespolenia zestawiono z wartościami granicznymi podanymi w normie Eurokod 4. Jak wynika z przeprowadzonej analizy, wszystkie badane elementy uzyskały wyższą wartość naprężeń ścinających w płaszczyźnie zespolenia niż wartość podana w tablicy normowej EC4, zarówno po 28 dniach jak i po badaniu skurczu betonu. Zgodnie z zaleceniami określonymi w normie PN-EN 1994-1-1-2008, wartość obliczeniowych naprężeń ścinających zależy jedynie od rodzaju przekroju elementów ściskanych. Należy podkreślić, że zalecenia normowe dotyczą jedynie elementów wykonanych z betonu zwykłego, ale wydaje się, że nawet w tym przypadku warunki klasyfikacji granicznej nośności na ścinanie τRd wydają się być niewystarczające. W związku z tym wydaje się, że powinny zostać przeprowadzone kolejne badania w celu określenia obliczeniowej nośności na ścinanie dla elementów wykonanych z betonu SCC.
Źródło:
Archives of Civil Engineering; 2022, 68, 3; 125--137
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Overall buckling performance of high strength steel welded I-sections under combined axial compression and bending
Autorzy:
Huang, Bing
Zhang, Wen-Fu
Powiązania:
https://bibliotekanauki.pl/articles/2174009.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
połączenie belka-słup
ściskanie osiowe
zginanie
analiza elementów skończonych
stal o wysokiej wytrzymałości
wyboczenie
dwuteownik spawany
beam-column connection
axial compression
bending
finite element analysis
high strength steel
overall buckling
welded I-section
Opis:
This paper presents a numerical investigation into the high strength steel (HSS) welded I-section overall buckling performance with respect to the major axis under combined axial compression and bending. The validation of FE models compared with the existing test data to verify the appropriateness of the element division and boundary condition was firstly conducted. In line with the FE arrangement verified, separate 890 numerical models, covering a broader range of eight steel grades (460 MPa, 500 MPa, 550 MPa, 620 MPa, 690 MPa, 800 MPa, 890 MPa and 960 MPa), different overall slenderness and various eccentricities were designated. Subsequently, the comparison of the resistance prediction codified design rules in EN1993-1-1, ANSI/AISC 360-10 and GB50017-2017 was preferentially operated, by the instrumentality of the normalized axial compression-bending moment curves. The results graphically revealed that, the provision given in ANSI/AISC 360-10 concerned in the present work was the most loose, whereas, the corresponding content set out in EN1993-1-1 and GB50017-2017 was relatively on the safe side. Taking account of the FE results, the conservative shortcomings of the considered rules in EN1993-1-1 and GB50017-2017 were further highlighted. Especially, the disparity of EN1993-1-1 and numerical results was higher to 27%, from the perspective of a definition given in the present work. In contrast, the provision in ANSI/AISC 360-10 yielded a relatively accurate prediction, on average. Based on the numerical program, an alternative formula for the HSS welded I-section beam-columns with a general expression form was sought, which intimately reflected the effect of overall slenderness.
Źródło:
Archives of Civil Engineering; 2022, 68, 3; 369--384
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Buckling resistance of quasi-straight H-section beam-columns under unequal end moments
Wyboczenie pozornie prostych elementów dwuteowych szerokostopowych, ściskanych i zginanych momentami podporowymi o różnych wartościach i znaku
Autorzy:
Giżejowski, Marian Antoni
Szczerba, Radosław Bronisław
Stachura, Zbigniew
Gajewski, Marcin Daniel
Powiązania:
https://bibliotekanauki.pl/articles/1853685.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metoda ogólna
przemieszczenie duże
wyboczenie giętno-skrętne
stal walcowana
przekrój bisymetryczny
element dwuteowy szerokostopowy
element ściskany
element zginany
general method
large displacement
flexural-torsional buckling
rolled steel
bisymmetric cross-section
H-section
beam-column connection
Opis:
Steel prismatic elements of equal flanges double-tee section subject to major axis bending and compression, unrestrained in the out-of-plane direction between the supports, are vulnerable to buckling modes associated with minor axis flexural and torsional deformations. When end bending moments are acting alone on the quasi-straight member, the sensitivity to lateral-torsional buckling (LTB) is very much dependent upon the ratio of section minor axis to major axis moments of inertia, and additionally visibly dependent upon the major axis moment gradient ratio. In the case of major axis bending with the presence of a compressive axial force, even of rather small value in relation to the section squash resistance, there is a drastic reduction of structural elements in their realistic lengths to maintain a tendency to fail in the out-of-plane mode, governed by the large twist rotation. Increasing the load effects ratio of dimensionless axial force to dimensionless maximum major axis bending moment, the buckling mode goes away from that of lateral-torsional one, starting to become that closer to the minor axis flexural buckling (FBZ) mode. Different aspects of the flexural-torsional buckling (FTB) resistance of the typical rolled H-section beam-column with regard to the General Method (GM) formulation, developed by the authors elsewhere and based on the parametric finite element analysis, are dealt with in this paper. Investigations are concerned with different member slender ratio, different moment gradient ratios and different load effects ratio. Final conclusions are related to practical applications of the proposed format of General Method in relation to the effect of large displacements on the FTB resistance reduction factor described through the dimensionless measure of action effects and the FTB relative slenderness ratio of quasi-straight beam-columns.
Dwuteowniki stalowe o przekroju bisymetrycznym, poddawane ściskaniu i zginaniu względem głównej osi bezwładności przekroju, są wrażliwe na wyboczenie względem osi mniejszej bezwładności, przy jednoczesnej podatności na deformacje zgięciowe i skręcenie względem tej osi bezwładności. Analizy numeryczne wykazały, że w sytuacji, kiedy na końcach elementu quasi-idealnego występuje obciążenie podporowymi momentami zginającymi, wrażliwość na wyboczenie giętno-skrętne zależy w głównej mierze od stosunku momentów bezwładności analizowanego przekroju oraz dodatkowo zależy, i to w sposób istotny, od gradientu momentu względem głównej osi bezwładności przekroju. W przypadku zginania względem przekrojowej głównej osi bezwładności (osi y-y) z udziałem siły ściskającej, nawet o bardzo małej wartości w porównaniu z siłą powodującą uplastycznienie (równą nośności przekroju klasy 1 na ściskanie), następuje drastyczna redukcja nośności elementów o typowo konstrukcyjnych długościach. Na podstawie przeprowadzonych obliczeń można zaobserwować, że wyboczenie następuje wskutek zginania w płaszczyźnie mniejszej bezwładności przekroju, któremu towarzyszą znaczne skręcenia przekroju. W miarę wzrostu wartości współczynnika obciążenia, który definiujemy jako stosunek bezwymiarowej siły osiowej do bezwymiarowego maksymalnego momentu zginania względem osi większej bezwładności, następuje oddalanie się krzywej wyboczeniowej od tej dla wyboczenia giętno-skrętnego i zbliżenie się do krzywej dla wyboczenia względem osi mniejszej bezwładności. W niniejszej pracy przeanalizowano wpływ wybranych czynników na nośność przy wyboczeniu giętno-skrętnym typowego elementu stalowego, definiowaną w ujęciu tzw. eurokodowej metody ogólnej, rozwijanej przez autorów w innych pracach. Do analiz parametrycznych wykonywano metodę elementów skończonych (MES).
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 323-349
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical study on the dynamic response of a concrete filled steel tubular long column under axial impact by a rigid-body
Autorzy:
Qi, Han
Chen, Shuohui
Zou, Jianlei
Zhang, Huidi
Liu, Mengsha
Ju, Jinsan
Sang, Xiuxing
Powiązania:
https://bibliotekanauki.pl/articles/2055059.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
concrete filled steel tubular long column
rigid body
impact load
dynamic response
Opis:
In this study, refined finite element models of concrete filled steel tubular long columns with length diameter ratio (L/D) of 50 were established, and their dynamic responses under a rigid-body impact were explored. It is found that the form of impact load is only related to and can be predicted from the impact velocity of the rigid-body. The change of axial stress and strain with time is synchronous with that of the impact load. Furthermore, the variation characteristics of axial stress and strain with time are mainly related to the initial velocity of the rigid-body.
Źródło:
Journal of Theoretical and Applied Mechanics; 2021, 59, 4; 551--563
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055983.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). W artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odporność ogniowa konstrukcji słupowych zabezpieczonych okładzinami z gipsu syntetycznego
Fire resistance of pole structures protected with synthetic plastering
Autorzy:
Kania, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2055957.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
konstrukcja prętowa
słup stalowy
zabezpieczenie ogniochronne
okładzina gipsowa
gips syntetyczny
odporność ogniowa
ściana gipsowa
izolacyjność ogniowa
pomiar temperatury
klasyfikacja ogniowa
bar structure
steel column
fire barrier
gypsum panel cladding
synthetic gypsum
fire resistance
gypsum wall board
fire insulation
temperature measurement
fire classification
Opis:
Konstrukcje prętowe, do jakich zaliczamy słupy, nie pełnią zwykle funkcji oddzielającej, w związku z czym powinny spełniać jedynie kryterium nośności ogniowej (R). Jednak w sytuacji, gdy słup tworzy ciągłą przegrodę z przylegającą do niego ścianą, wymagane są w stosunku do niego także dwa pozostałe kryteria: szczelności (E) oraz izolacyjności ogniowej (I). w artykule przedstawiono rozwiązanie zabezpieczeń przeciwpożarowych stalowych słupów konstrukcyjnych z wykorzystaniem okładzin z gipsu syntetycznego, materiału odpadowego uzyskanego w procesie odsiarczania spalin z paliw kopalnych metodą mokrą wapienną.
Bar structures, which include columns, usually do not have a separating function, and therefore should only meet the fire resistance (R) criterion. However, when a column forms a continuous partition with an adjacent wall, two other criteria are also required: tightness (E) and fire insulation (I). The article presents a fire protection solution for structural steel columns with the use of synthetic gypsum cladding, a waste material obtained in the process of desulphurization of fossil fuels using the wet lime method.
Źródło:
Przegląd Budowlany; 2021, 92, 11-12; 119--121
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the columns buckling length of unbraced steel frames with semi-rigid joints
O długości wyboczeniowej słupów niestężonych ram stalowych z węzłami podatnymi
Autorzy:
Krystosik, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/1853674.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stateczność
węzeł podatny
rama stalowa
długość wyboczeniowa
połączenie półsztywne
słup
stability
unbraced frame
steel frame
buckling length
semi-rigid joint
column
Opis:
The paper presents the issue of unbraced and semi-rigid steel frames stability with special attention paid to the determination problem of columns buckling length Lcr in these frames. The paper discusses ways of buckling length determination in frames columns with the use of well known, European and American standard procedures, as well as numerical method of stability analysis based on the Finite Element Method (FEM). The presented procedures and analysis methods in calculations of certain steel frames with semi-rigid joints were used. On the basis of obtained results, it has been shown that in many practical cases, the simplified standard procedures of columns buckling length determination can give the results burdened with errors. These errors can have a significant influence on accuracy of columns resistance calculations. The issues presented in the paper are very important from the practical point of view, and according to the author, they can be used in the practical design of unbraced steel frames.
W pracy przedstawiono zagadnienie stateczności niestężonych ram stalowych o węzłach podatnych, ze szczególnym zwróceniem uwagi na problem określenia długości wyboczeniowej Lcr słupów tych ram. W pierwszej części pracy przedstawiono trzy metody określania długości wyboczeniowej (Lcr = Lc·μ). Pierwsza metoda bazuje na wytycznych ECCS i jest uzupełnieniem europejskich norm w zakresie projektowania ram stalowych. Z kolei druga metoda opiera się na wytycznych AISC i jest zalecanym sposobem określania długości Lcr przez amerykańskie normy.Obydwa sposoby obliczeń wykorzystują bardzo podobne podejście, polegające na analizie warunków zamocowania rozpatrywanego elementu (słupa), przy czym odbywa się to na podstawie analizy wyizolowanego fragmentu ramy, w którym całkowicie pomija się fakt występowania sił normalnych. Trzecia, prezentowana w pracy metoda obliczeń długości wyboczeniowych słupów wykorzystuje wyniki analizy stateczności w ujęciu MES (Metody Elementów Skończonych). W metodzie tej wymagane jest przeprowadzenie globalnej analizy stateczności ustroju, uwzględniając przy tym odpowiedni model obciążenia, a więc i rozkład sił normalnych w konstrukcji. W drugiej części pracy przedstawiono pewne przykłady liczbowe ram stalowych, w których wyznaczono współczynniki długości wyboczeniowych μ słupów za pomocą wszystkich trzech prezentowanych metod. W pierwszym przykładzie poddano analizie dwunawową, trójkondygnacyjną ramę, uwzględniając w obliczeniach trzy różne przypadki obciążeń. W drugim przykładzie liczbowym wyznaczono poszukiwane wartości współczynników μ słupów dla trójnawowej, trójkondygnacyjnej ramy stalowej, w której węzły wewnętrzne (rygiel-słup), jak również węzły zewnętrzne (podstawy słupów) są węzłami podatnymi.
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 539-556
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pseudo-static test of steel-glulam composite beam-to-column exterior joints
Autorzy:
Duan, Shaowei
Liu, Xinglong
Yuan, Jian
Wang, Zhifeng
Powiązania:
https://bibliotekanauki.pl/articles/1853633.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
połączenie belka-słup
połączenie zewnętrzne
belka stalowa klejona
belka kompozytowa
test pseudostatyczny
forma przekroju
rozpraszanie energii
nośność
beam to column joint
exterior joint
steel-glulam beam
composite beam
pseudo-static test
cross-section form
energy dissipation
capacity
Opis:
Steel-glulam structure is a new type of composite structure,glulam have lateral support effect on steel plate, that can prevent premature buckling of steel plate and improve the stability of steel structure. In order to study the influence of column’s cross-section form on the seismic performance of steel-glulam composite beam-to-column exterior joint, the column’s cross-section form was taken as the basic variable (glulam rectangular section , H-beam section and H-beam-glulam rectangular section were used respectively). The pseudo-static tests of three composite beam-to-column joints were carried out to observe the different failure modes, and obtain the mechanical performance indexes. The experiment results demonstrated that: The energy dissipation capacity of beam-to-column exterior joint composed of glulam column was the worst, the ultimate bearing capacity and stiffness were the lowest. The ultimate bearing capacity of the exterior joints formed by the H-beam column and the H-beam-glulam composite column were both high, and their ductility coefficients were similar, while the former had better energy dissipation capacity.
Źródło:
Archives of Civil Engineering; 2021, 67, 1; 147-161
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ambiguity in determining the critical temperature of a steel sway frame with semi-rigid joints
Niejednoznaczność w wyznaczaniu temperatury krytycznej stalowej ramy przechyłowej z podatnymi węzłami
Autorzy:
Maslak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849756.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
rama stalowa
temperatura krytyczna
węzeł sztywny
węzeł półsztywny
węzeł doczołowy
węzeł belka-słup
fire resistance
steel frame
critical temperature
fully rigid joint
semi rigid joint
end plate joint
beam to column joint
Opis:
The problem of uniqueness and representativeness of steel frame fire resistance assessment is considered in this paper. The thesis, that the selection of analysis method determines the result in both qualitative and quantitative terms is given scrutiny. It is also shown, that the differences between computed values may be significant. The selection of an appropriate computational model for an analysis of this type seems to be especially important, as the possible overestimation of the fire resistance determined during computation is equivalent to an unjustified optimism of the user with respect to the safety level warranted. In the considerations presented here the critical temperature determined for the whole bearing structure is considered as the measure of sought resistance. The determined temperature is associated with the bearing structure reaching the bearing capacity limit state subject to fire conditions, treated as accidental design situation. Two alternative computational methods have been applied during calculations: the first one - classical, based on 1st order statics and using the buckling length concept for members of the considered frame, and the second one - taking account of 2nd order phenomena via simple amplification of the horizontal loads applied to the frame. Special attention has been paid to the influence exerted on the final fire resistance of the considered structure by the real joint rigidity, decreasing with increasing temperature of the structural members. The obtained results differ not only in the value of determined temperature but also in the indicated location of the weakest frame component, determining its safety.
W pracy rozważa się problem jednoznaczności i reprezentatywności oszacowania odporności ogniowej ramy stalowej. Weryfikacji poddano tezę, że wybór metody analizy determinuje uzyskany wynik zarówno pod względem ilościowym jak i jakościowym, a różnice pomiędzy wyliczonymi wartościami mogą okazać się znaczące. Dobór miarodajnego modelu obliczeniowego w tego typu analizie wydaje się być szczególnie ważny, bowiem ewentualne przeszacowanie wyznaczonej z obliczeń odporności jest równoznaczne z nieuzasadnionym optymizmem użytkownika budynku co do gwarantowanego mu poziomu bezpieczeństwa. W prezentowanych rozważaniach miarą poszukiwanej odporności jest temperatura krytyczna specyfikowana dla całego ustroju nośnego. Nie zależy ona od prognozowanego scenariusza rozwoju pożaru i z tego względu może zostać uznana za pewnego rodzaju charakterystykę samej konstrukcji. Wyznaczana temperatura kojarzona jest z osiągnięciem przez ustrój nośny stanu granicznego nośności w warunkach pożaru traktowanego jako wyjątkowa sytuacja projektowa. Nie oznacza to jednak natychmiastowej katastrofy badanej konstrukcji ale jedynie sytuację, gdy prawdopodobieństwo tego rodzaju zdarzenia staje się już na tyle duże że nie może być dalej akceptowane. Do szczegółowej analizy wykorzystano dwie alternatywne procedury obliczeń: pierwszą - opartą o klasyczną statykę pierwszego rzędu, z wykorzystaniem koncepcji długości wyboczeniowej elementów badanej ramy, i drugą - uwzględniającą efekty drugiego rzędu przez prostą amplifikację przyłożonego do tej ramy obciążenia poziomego.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 611-632
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigating the factor of safety for the design of columns using properties of steel rebar’s manufactured in Pakistan
Autorzy:
Zaidi, Safdar Abbas
Saeed, Muhammad Arsalan
Haider, Farhan
Powiązania:
https://bibliotekanauki.pl/articles/1849760.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
współczynnik redukcji wytrzymałości
analiza wytrzymałościowa
interakcja
moment obciążenia
pręt stalowy
słup
strength reduction factor
strength analysis
load moment
interaction
steel rebar
column
Opis:
This paper includes the behaviour of RC column, using the steel strength data employed by Rafi et al. (2014). Eccentric short columns are studied for this purpose, both tension and compression controlled sections, are analysed considering the current design practice of Pakistan. Three cross sections were analysed using different steel percentages against load-moment interaction and the strength analyses. Concrete strength is also varied in this analysis. The load moment interaction diagrams were observed in major and minor axes and strength analysis is made for compression controlled and tension controlled sections. In this analysis it is observed that a section designed as a tension controlled is giving brittle failure at certain limit which should be avoided. Considering this scenario, several random cross sections are analysed, strength reduction factors for eccentric and pure axial columns are computed. Conclusions are made on behalf of this analysis for different types of column design.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 61-78
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies