Wyświetlanie 1-2 z 2
Tytuł:
Resistance of Steel Fasteners Subjected to Shear at Public Arenas in Normal and Fire Temperatures - Probabilistic Approach
Autorzy:
Domański, T.
Powiązania:
https://bibliotekanauki.pl/articles/105019.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
steel structures
structural safety
steel bolt connections
fire safety
Opis:
The buildings with great grandstands are the public places where consequences of failure are very high. For this reason, according to EN 1990 they belong to CC3 class consequence of failure. The reliability class RC3 is associated with the consequences class CC3 [7, 8] and is defined by the β = 4.3 reliability index with probability of failure pf ≈ 8.54·10-6. Shear connections have to transfer forces between structural members – steel body and bolts with adequate degree of safety. The load-carrying mechanism of bolted shear connections is complex and analytical methods for predicting the shear resistance are not applicable. Instead the resistance of the connections may be determined using empirical formulas. The distributions of horizontal and shear resistance within steel body - bolts will be described depending on material characteristics of steel body and bolts components. The characteristic resistance of steel shear connection is obtained as minimum of two variables: bolds resistance and steel body resistance. Probability function of this minima will be defined and described in this paper. Laboratory tests provide the only practicable basis for specifying safety margins for ultimate strength connections. The determination of partial safety factors within shear connections will be presented according to EN1990. Design value of such resistance is specified as suitable fractile of log- normal probability distribution, calculated with the assumption that the acceptable probability of down-crossing is not greater than pf,ult ≈ 2.91·10-4. It means that the target reliability index, defined for the resistance, is taken as βR.req = 3.44, in accordance with the European recommendations (EN 1990).
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 17-24
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the load-carrying capacity of a bolted connection between a steel floor beam and a column
Analiza nośności połączenia śrubowego stalowej belki stropowej ze słupem
Autorzy:
Kasza, Przemysław
Nawrot, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2067589.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
steel constructions
bolt connections
designing
konstrukcje stalowe
połączenia śrubowe
projektowanie
Opis:
The paper analyses the load-carrying capacity of a bolted overlapping connection between a floor beam and a column. Three variants of the connection were considered: without the support seat and with support in the form of an angle bracket and a plate. The value of force acting on the connection was determined based on calculations made for the adopted conditions. The load-carrying capacity of bolts and plates for the assumed load was evaluated and the values of stress in the contact zone were compared for the analysed cases. It was demonstrated that the load-carrying capacity of bolted overlapping connections of the beam/column type depends on the adopted solution in terms of contact shape (presence or absence of a support seat), the type of support seat (if any) and the number, class and spacing of bolts. The results of the calculations showed that the most effective method of connection for the adopted assumptions is the connection with the support seat capital in the form of an angle bracket. The use of this type of beam support significantly reduces bolt tension and reduces the stresses occurring in the contact zone of the connected elements.
W pracy dokonano analizy nośności śrubowego połączenia zakładkowego belki stropowej ze słupem. Rozpatrywano trzy warianty połączenia: bez stołeczka podporowego oraz z oparciem belki na stołeczku podporowym w postaci kątownika oraz blachy. Dla przyjętych założeń wykonano obliczenia, na podstawie których określono wartość siły działającej na połączenie. Sprawdzono nośność śrub i blach dla przyjętego obciążenia oraz porównano wartości naprężeń w strefie styku dla analizowanych przypadków. Wykazano, że nośność śrubowych połączeń zakładkowych typu belka/słup zależy od przyjętego rozwiązania w zakresie ukształtowania styku (występowanie lub brak stołeczka podporowego), typu zastosowanego stołeczka podporowego (o ile występuje) oraz ilości, klasy i rozstawu śrub. Wyniki przeprowadzonych obliczeń wykazały, iż najefektywniejszym sposobem połączenia, dla przyjętych założeń, jest styk ze stołeczkiem podporowym w postaci kątownika. Zastosowanie tego rodzaju podparcia belki znacznie obniża wytężenie śrub oraz powoduje zmniejszenie naprężeń występujących w strefie przystykowej łączonych elementów.
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2020, 26 (176); 76-82
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies