Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "steam condenser" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Determining steam condensation pressure in a power plant condenser in off-design conditions
Autorzy:
Laskowski, Rafał
Smyk, Adam
Ruciński, Adam
Szymczyk, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1954999.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
thermal power plant
steam condenser
condenser model
steam condensation
pressure
reference parameters
steam condenser effectiveness
Opis:
The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 45-62
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Entropy generation in a condenser and related correlations
Autorzy:
Laskowski, R.
Jaworski, M.
Smyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/240683.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steam condenser
entropy generation
kondensator pary
generowanie entropii
Opis:
The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Źródło:
Archives of Thermodynamics; 2015, 36, 2; 27-48
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analyzis of the stream-air mixture during a flow through a tube bank inside a condenser
Autorzy:
Krzyślak, P.
Joachimiak, M.
Powiązania:
https://bibliotekanauki.pl/articles/175261.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condenser
pressure drop
steam-air mixture
water vapor condensation in a solution with air
partial pressure
Opis:
The paper presents the results of calculations related to the flow analysis of a tube bank taking into account the partial pressures of gases flowing through the condenser. Different mass share of the gas not condensing in the heat exchanger upstream to the first row of tubes and the partial pressures of water vapor and air have been taken into account. The value of the partial pressures of gases, pressures drop, temperature, velocity, Reynolds number, and air share in the subsequent rows of tubes have been calculated. This study is a basis for the analysis of heat exchange in the condenser considering the influence of the noncondensing gas. The increase in the share of air in the following rows of tubes results in an increase in the thermal resistance and condensation of increasingly lower mass of water vapor.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2014, 126; 131-140
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the effectiveness of the turbine condenser air extraction system using hydro ejectors
Autorzy:
Badur, J.
Kowalczyk, T.
Ziółkowski, P.
Tokarczyk, P.
Woźniak, M.
Powiązania:
https://bibliotekanauki.pl/articles/175162.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
condensation
steam condenser
Venturi nozzle
Dalton’s law
partial pressure
Opis:
The aim of the paper is to investigate the effectiveness of the 18K380 steam turbine condenser air extraction system using hydro ejectors. Motivation for the analysis was a need of improvement of the energy conversion ratio of the power plant. To achieve this goal it was necessary to establish efficiency of each subsystem of the energy cycle. The air extraction system is not a highly power consuming system but it has great impact on the steam cycle efficiency by influence on the condensation temperature. The air extraction system effectiveness depends on a weather conditions, exactly on the ambient temperature, which raises the question whether it is worth to modernize the hydro ejectors or replace them by a centrifugal vacuum pumps. To establish the vacuum system effectiveness a new innovative mass flow measuring system has been implemented to measure an air-steam mixture flow and the fraction of the air mass in the mixture. The measuring system is based on a Venturi nozzle supplemented with a temperature drop during the mixture expansion.
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2016, 131; 41-53
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies