Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stabilność chemiczna wody" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Application of the PHREEQC program to assess the chemical stability of tap water in Kielce
Zastosowanie programu PHREEQC do oceny stabilności chemicznej wody wodociągowej w Kielcach
Autorzy:
Metryka-Telka, Monika
Kowalik, Robert
Gawdzik, Jarosław
Gawdzik, Barbara
Gawdzik, Alicja
Powiązania:
https://bibliotekanauki.pl/articles/402211.pdf
Data publikacji:
2020
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
PHREEQC
water chemical stability
stability index
stabilność chemiczna wody
wskaźnik stabilności
Opis:
The research was conducted on samples of water in Kielce from two intakes: Białogon and Zagnańsk. The results of selected indicators for these waters were presented, among others, the most important ones influencing its chemical stability i.e. calcium or magnesium. Then, using the PHREEQC program, stability indices were calculated for water in Kielce from the two shots in question. In the next stage, the correctness of the water test method was checked by means of a program through the ionic balance of the water and comparison of pH of the water determined with the value determined by calculation. For the above mentioned activities, tables and calculations were prepared on the basis of which appropriate conclusions were made.
Badania przeprowadzono na próbkach wody w Kielcach pochodzące z dwóch ujęć: Białogon i Zagnańsk. Przedstawiono wyniki wybranych wskaźników dla tych wód, m.in. najważniejszych wpływających na ich stabilność chemiczną, tj. wapnia lub magnezu. Następnie, za pomocą programu PHREEQC, obliczono wskaźniki stabilności dla wód w Kielcach z dwóch ujęć, o których mowa. W kolejnym etapie sprawdzono poprawność metody badania wody za pomocą programu poprzez bilans jonowy wody i porównanie pH wyznaczonej wody z wartością wyznaczoną w wyniku obliczeń. Dla wyżej wymienionych czynności przygotowano tabele i obliczenia, na podstawie których wyciągnięto odpowiednie wnioski.
Źródło:
Structure and Environment; 2020, 12, 1; 41-45
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie procesu napowietrzania do desorpcji dwutlenku węgla z wody powierzchniowej na przykładzie wodociągu w Dębicy
The use of the aeration process for the desorption of carbon dioxide from surface water: A case study
Autorzy:
Zymon, W.
Powiązania:
https://bibliotekanauki.pl/articles/237816.pdf
Data publikacji:
2007
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
dwutlenek węgla
napowietrzanie
desorpcja
stabilność chemiczna wody
carbon dioxide
aeration
desorption
chemical stability of water
Opis:
Na przykładzie wodociągu w Dębicy omówiono problem stabilizacji składu chemicznego wody o charakterze agresywnym, spowodowanym stosowaniem dużych dawek koagulantu podczas oczyszczania wody powierzchniowej. Przeprowadzono analizę skuteczności usuwania agresywnego dwutlenku węgla przy użyciu metody chemicznej (dawkowanie węglanu sodu) i fizycznej (napowietrzanie). Biorąc pod uwagę skuteczność obu procesów oraz warunki eksploatacyjne w stacji oczyszczania wody, wybrano metodę desorpcji dwutlenku węgla przy użyciu powietrza w kolumnowym desorberze z pierścieniami Białeckiego. Zakładając wymaganą jakość wody oczyszczonej, określono podstawowe parametry projektowe kolumny desorpcyjnej do usuwania dwutlenku węgla. Przestawiono także sposób adaptacji nieczynnej kolumny filtracyjnej na desorber kolumnowy. Analiza ponadrocznej eksploatacji urządzenia do usuwania dwutlenku węgla z wody w wodociągu w Dębicy potwierdziła skuteczność przyjętego rozwiązania.
With the Waterworks of Debica as a case in point, the paper addresses the problem of stabilizing the chemical composition of the water whose aggressive character is attributable to the high coagulant doses applied in the course of the treatment process. Two methods for the removal of aggressive carbon dioxide, a chemical one (dosage of sodium carbonate) and a physical one (aeration), were made subject to analysis in view of their efficiencies. Taking into account the efficiencies of the two processes and the operating conditions at the water treatment station, the method of carbon dioxide desorption (with air in a column desorber packed with Bialecki rings) was chosen. Upon setting the desired quality of the treated water, the basic design parameters of the desorption column for carbon dioxide removal were determined. It was also shown how to adapt an idle filter column in order to make it act as a desorber. The analysis of a one-year operation of the unit for carbon dioxide removal from water at the Waterworks of Debica has substantiated the efficiency of the design adopted.
Źródło:
Ochrona Środowiska; 2007, R. 29, nr 4, 4; 65-68
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of chemical stability of tap water in terms of required level of technological safety
Analiza stabilności chemicznej wody wodociągowej pod kątem wymaganego poziomu bezpieczeństwa technologicznego
Autorzy:
Pietrucha-Urbanik, K.
Tchórzewska-Cieślak, B.
Papciak, D.
Skrzypczak, I.
Powiązania:
https://bibliotekanauki.pl/articles/205102.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
chemical stability of water
corrosion indice
technological safety
risk criteria
stabilność chemiczna wody
wskaźnik korozji
bezpieczeństwo technologiczne
kryteria ryzyka
Opis:
The main goal of this work is to show the new approach to determining safety technological levels (SLs) in terms of water quality and its chemical stability, as well as issues of water corrosion properties in water distribution systems (WDSs), due to the fact that water supply pipes are prone to corrosion. In the paper the methodology of determining the risk associated with threat to technical infrastructure was considered. The concept was studied on the basis of real operational data from the water treatment plant. The probability of exceeding the individual parameters for WTPI is slightly larger than for WTPII, which means that this water treatment process may cause lack of chemical stability in the water supply network. Operators should anticipate in the process of designing water distribution system, using proper materials, as to ensure an adequate level of safety from the water source to the water recipient. It should be noted that it is necessary to adjust the material of internal installation of water supply networks to the parameters of the water. At present, there are no correlations between the designing step and water parameters. It was concluded that to protect the water supply infrastructure, which belongs to critical infrastructure, water company should put more emphasis on distribution of stable water that has not potentially corrosion properties. Some suggestions were made for the protection of WDS and to ensure safety of system functioning and long-term usability of water pipes.
Głównym celem pracy jest przedstawienie nowego podejścia do określania poziomów technologicznych bezpieczeństwa (SL) w zakresie jakości wody i jej stabilności chemicznej, a także właściwości korozyjnych wody w systemach dystrybucji wody (WDS), ze względu na fakt, iż przewody wodociągowe są podatne na korozję. W pracy przedstawiono metodologię określania ryzyka związanego z wystąpieniem zagrożeń dla infrastruktury technicznej. Analiza została wykonana na podstawie uzyskanych danych eksploatacyjnych ze stacji uzdatniania wody. Prawdopodobieństwo przekroczeń poszczególnych parametrów w przypadku WTPI jest nieznacznie większe od WTPII, co oznacza iż ten proces uzdatniania wody może powodować brak zachowania stabilności chemicznej w sieci wodociągowej. Operatorzy powinni przewidzieć w procesie projektowania systemu dystrybucji wody, użycie odpowiednich materiałów, tak aby zapewnić odpowiedni poziom bezpieczeństwa od źródła wody do odbiorcy. Należy zauważyć, że niezbędne jest dostosowanie materiału wewnętrznej instalacji sieci wodociągowej do parametrów wody nie odwrotnie. W chwili obecnej nie ma korelacji pomiędzy etapem projektowania, a parametrami wody. W celu ochrony infrastruktury wodociągowej, które należą do infrastruktury krytycznej, przedsiębiorstwo wodociągowe powinna położyć większy nacisk na dystrybucję stabilnej wody, która nie ma właściwości korozyjnych. W pracy zaproponowano podjęcie działań zapewniających ochronę systemu dystrybucji wody przed utratą stabilności chemicznej wody.
Źródło:
Archives of Environmental Protection; 2017, 43, 4; 3-12
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena mikrobiologiczna osadów wodociągowych, na przykładzie wybranego Systemu Zaopatrzenia w Wodę
The Microbiological Evaluation of Deposits Come from Water Network on the Example of Selected Water Supply System
Autorzy:
Szuster-Janiaczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818065.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady wodociągowe
biofilm
stabilność chemiczna
stabilność biologiczna wody
korozja
deposits
chemical water stability
biological water stability
corrosive properties
Opis:
The study described herein was carried out on a technical scale on a water supply system servicing approximately 350 thousand inhabitants. The total length of the water mains and distribution pipelines in the area under review approximates 1 744 km and 37 264 water supply connections. The greater part of the water supply area is compact, and a region (a maximum located to the south) is clearly separated from the rest. Because the Waterworks Company, which manages the examined SDW, does not exploit its own intakes and water treatment plants, it has to purchase the water from two external suppliers (D-1 and D-2). The studied area is supplied with water from water mains through 21 points (P1-P21) which, in many cases, are also points of water pressure reduction (reduction stations) or elevation (pumping stations). In 8 of the 21 points of purchase, through appropriate installations, phosphate corrosion inhibitors are dispensed to the water. In an article, the microbiological evaluation of deposits collected from five points in the water distribution system was conducted. The analyzed deposits were located at three different materials: cast iron, plastic, and asbestos cement, which in terms of age ranged from 3 to 40 years. Samples of deposits were collected using the same method for various months during one calendar year. Bacteriological analysis of samples included determination of: total number of mesophilic bacteria (growing at 37°C), psychrophilic (growing at 22°C), coliform, faecal coliform (thermotolerant) or E. coli, fecal streptococci, Clostridium perfingens, bacteria of the Pseudomonas genus, bacteria precipitating iron, anaerobic bacteria sulfate reducing (SRB-initiate corrosion processes), actinomycetes and fungi which are the possible contamination of the soil. Results of microbiological testing showed that the surface of the pipes developed biofilm, which is a significant reservoir of microorganisms, which is a phenomenon often occurring in water distribution systems. The analysis showed a variety of deposits in terms of microbiological, depending on the type of material which they were originally placed on. In the case of sediment samples taken from the plastic pipe, the size of the bacteria grown in the two temperatures was several times higher than in the case of samples taken from the cast iron pipe. In the case of the water sample taken from the plastic, the size of bacteria grown at both temperatures exceeded the limit values for water several times.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 815-827
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wtórnego zanieczyszczenia niestabilnej chemicznie wody w systemie dystrybucji
Recontamination of Chemically Unstable Water in the Distribution System
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237225.pdf
Data publikacji:
2005
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
korozyjność wody
stabilność chemiczna
system dystrybucji
produkty korozji
water corrosivity
chemical stability
distribution system
tap water
corrosion products
Opis:
Brak stabilności chemicznej wody wprowadzanej do systemu dystrybucji jest przyczyną pogarszania jej jakości, w większości próbek wody nawet do poziomu ponadnormatywnego. W badaniach wykazano, że największe zmiany składu fizyczno-chemicznego wody dotyczyły zawartości żelaza ogólnego i nierozpuszczonego, a także barwy i mętności wody. Dodatkowo, wraz ze wzrostem odległości punktu poboru wody od zakładu oczyszczania wody, wzrastało zużycie chloru wolnego, co stwarzało warunki do rozwoju mikroorganizmów. Stwierdzono, że procesy zachodzące podczas transportu wody w sieci wodociągowej powodowały intensyfikację agresywności korozyjnej wody, co sprzyjało rozpuszczaniu osadów zgromadzonych w rurociągach, będących źródłem zanieczyszczenia wody głównie produktami korozji żeliwnych i stalowych przewodów wodociągowych.
Chemical instability is the main contributor to the deterioration of water quality during transport in the distribution system. In the investigated water distribution system, the most noticeable changes in the water quality parameters were those in total and insoluble iron concentrations, colored matter content and turbidity. The persistence of low disinfectant concentrations promoted bacterial regrowth and water contamination due to the metabolism of bacterial by-products. The processes that occured in the distribution system during water transport enhanced the corrosivity of the water, which favored the dissolution of pipe encrustation. The dominating pollutants were found to be products of cast iron and steel pipe corrosion.
Źródło:
Ochrona Środowiska; 2005, R. 27, nr 4, 4; 34-38
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Główne przyczyny wtórnego zanieczyszczenia wody w systemie dystrybucji
Major contributors to self-contamination of water in distribution systems
Autorzy:
Świderska-Bróż, M.
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/237133.pdf
Data publikacji:
2006
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
stabilność chemiczna
stabilność biologiczna
biofilm
warunki hydrauliczne
prędkość przepływu wody
korozja
tap water
chemical stability
biological stability
corrosion
hydraulic conditions
flow velocity
Opis:
Przeanalizowano główne przyczyny wtórnego zanieczyszczenia wody w systemie dystrybucji. Scharakteryzowano brak stabilności chemicznej i biologicznej wody wprowadzanej do sieci wodociągowej, zapewnienie odpowiedniej zawartości dezynfektanta oraz zmienne warunki hydrauliczne panujące w systemie dystrybucji. Wykazano, że brak stabilności chemicznej wody sprzyja intensyfikacji korozji przewodów wodociągowych oraz gromadzeniu osadów na powierzchni rurociągów, a w konsekwencji - jej wtórnemu zanieczyszczeniu produktami korozji. Stwierdzono, że wzrost porowatości i chropowatości przewodów wodociągowych sprzyja rozwojowi mikroorganizmów w biofilmie. Obecność substratów pokarmowych w wodzie warunkuje rozwój mikroorganizmów, wzrost intensywności rozwoju biofilmu oraz poziomu wtórnego skażenia wody drobnoustrojami. O stopniu wtórnego zanieczyszczenia wody i ilości uwalnianych składników osadów zgromadzonych w przewodach wodociągowych decydują ponadto warunki hydrauliczne panujące w systemie dystrybucji wody.
The main contributory factors in the self-contamination of the water pumped into the distribution system can be itemized as follows: lack of chemical and biological stability of the water itself, inadequate amount of the disinfecting agent, and variability of the hydraulic conditions in the distribution system. There is evidence that the lack of chemical stability supports the development of corrosion in the water-pipe network and stimulates encrustation growth on the pipe surface, thus contributing to self-contamination of the water with corrosion products. The rise in pipe porosity and wall roughness was found to favour microbial growth in the biofilm. The presence of nutrients in the water, which accounts for microbial growth, increases the rate of biofilm growth and raises the level of self-contamination of the water with microorganisms. The extent of self-contamination and the amount of the encrustation components released in the water pipes are also noticeably influenced by the hydraulic conditions in the distribution system.
Źródło:
Ochrona Środowiska; 2006, R. 28, nr 4, 4; 29-34
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zmian jakości wody w przewodach wodociągowych z wykładziną cementową
Water quality variations in cement-lined water-pipe networks
Autorzy:
Wąsowski, J.
Kowalski, D.
Kowalska, B.
Kwietniewski, M.
Zawilska, M.
Powiązania:
https://bibliotekanauki.pl/articles/236692.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda wodociągowa
sieć wodociągowa
wykładzina cementowa
stabilność chemiczna
zanieczyszczenie wody
tap water
water-pipe network
cement lining
chemical stability
water contamination
Opis:
Badania przeprowadzone w instalacji modelowej zasilanej wodą podziemną wykazały, że woda kontaktująca się z wykładziną cementową stopniowo traciła właściwości agresywne i nabierała zdolności do wytrącania węglanu wapnia. Świadczyło to o przechodzeniu składników cementu z wykładziny do wody wodociągowej. Poza głównymi składnikami (wapń, magnez, glin) stwierdzono obecność w wodzie także pierwiastków śladowych (cynk, bar, chrom, ołów, nikiel, kobalt), przy czym nie były to ilości znaczące. Wykazano, że wymywanie pierwiastków z cementu przebiegało intensywniej do wody poddawanej chlorowaniu. Końcowa zawartość wszystkich oznaczonych pierwiastków w wodzie po kontakcie z wykładziną cementową była znacznie poniżej wartości dopuszczalnych w wodzie przeznaczonej do spożycia.
Experiments performed in a model pipe system fed with underground water demonstrated that tap water exposed to cement-lining gradually lost its corrosive properties and continued to develop its potential for calcium carbonate precipitation. This was an indication that cement components were released from the lining into the water residing in the pipes. Apart from its main components (calcium, magnesium and aluminum), the water contained small quantities of trace elements (zinc, barium, chromium, lead, nickel and cobalt). The study produced the following findings: leaching of elements from the cement lining was enhanced upon exposure to chlorinated water, and the final concentration values of all the elements detected in the water after contact with the cement lining were much lower than those permissible for drinking water.
Źródło:
Ochrona Środowiska; 2012, 34, 1; 53-58
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies