Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "specific conductivity" wg kryterium: Temat


Tytuł:
The influence of electronic exposure and heat treatment on the electrical conductivity of epoxy polymer materials
Autorzy:
Udovytska, Yuliia
Luniov, Sergiy
Kashytskyi, Vitalii
Maslyuk, Volodymyr
Megela, Ivan
Powiązania:
https://bibliotekanauki.pl/articles/950073.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
irradiation
epoxy resin
specific electrical conductivity
heat treatment
Opis:
The influence of electron irradiation fluxes with energy of 12 MeV and heat treatment on the electrical properties of epoxypolymers with PEPA content of 11, 12 and 13 wt.h. per 100 wt. including epoxy resin. It is show that the electrical conductivity of epoxypolymer increases with electron irradiation fluxes greater than 10 kGy. It found that extra heat treatment of irradiated samples with a hardener content of 12 wt. h. hours leads to an increase in their electrical conductivity. The nature of the obtained dependences of electrical conductivity is determine by the processes of cross-linking, radiation, thermal destruction and mass fraction of the hardener. Radiation-stimulated increase in the conductivity of epoxypolymers can be use to create conductive protective coatings and sensor electronics elements.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2020, 23(1); 81-89
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania przewodności elektrolitycznej właściwej wód opadowych w rejonie Bielska-Białej
The study on specific electrical conductivity of water precipitation in Bielsko-Biała region
Autorzy:
Kasza, H.
Powiązania:
https://bibliotekanauki.pl/articles/400333.pdf
Data publikacji:
2015
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wody opadowe
przewodność elektrolityczna właściwa
rain water
specific electrical conductivity
Opis:
Przedstawiono podsumowanie wyników wieloletnich badań przewodności elektrolitycznej właściwej wód opadowych, prowadzonych w siedmiu punktach zlokalizowanych wokół Bielska-Białej. Na każdym ze stanowisk czas badań wynosił około jednego roku. Badania prowadzono w latach 2002–2010. Zebrane próbki opadów atmosferycznych cechowały się dużym zróżnicowaniem przewodności właściwej (od 1,8 μS·cm-1 do 188,5 μS cm-1); średnia arytmetyczna i ważona dla wszystkich pomiarów wyniosła odpowiednio 36,5 μS·cm-1 i 29,9 μS·cm-1. Najczęściej notowano opady o przewodnictwie „lekko podwyższonym” (15,1–30,0 μS·cm-1) i „znacznie podwyższonym” (30,1–45,0 μS·cm-1) – odpowiednio 36,6% i 25,9% prób opadów. Próbki opadów kwalifikowanych jako nie zanieczyszczone (< 15 μS·cm-1) odnotowano w każdym z punktów badawczych. Stanowiły one łącznie 8,9% prób. Wystąpiły sezonowe zmiany przewodności właściwej opadów atmosferycznych. W sezonie grzewczym była ona wyższa niż w ciepłej porze roku. Przewodność wód opadowych formowana była w dużej mierze przez zanieczyszczenia nadchodzące z kierunku zachodniego i południowo-zachodniego oraz miejscowe źródła ich emisji.
The results of long-term studies on specific electrical conductivity of water precipitation conducted in seven re-search points located near Bielsko-Biała were presented. At each point a period of investigation lasted ca. 1 year. The research was performed in the year range 2002–2010. The collected samples of precipitation were characterized by a great diversity of conductivity (1.8–188.5 μS·cm-1); arithmetic and weighted average of all measurements was respectively 36.5 μS·cm-1 and 29.9 μS·cm-1. Most frequently, conductivity of rain water was “slightly increased” (15.1–30.0 μS·cm-1) and “significantly increased” (30.1–45.0 μS·cm-1), respectively 36.6% and 25.9% of the total samples. Samples of precipitation classified as not contaminated (<15 μS· cm-1) were observed in each of the re-search points. They represented 8.9% of the all samples. There were seasonal changes in the conductivity of precipitation. During the heating season the conductivity was higher than in the warm season. Rainwater conductivity was formed mainly by pollution coming from the west and southern-west direction, and by local sources of its emission.
Źródło:
Inżynieria Ekologiczna; 2015, 41; 166-172
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic Susceptibility and Heavy Metal Content in Dust From the Lime Plant and the Cement Plant in Opole Voivodeship
Podatność magnetyczna i zawartość metali ciężkich w pyłach z zakładu wapienniczego w województwie opolskim
Autorzy:
Gołuchowska, B.
Strzyszcz, Z.
Kusza, G.
Powiązania:
https://bibliotekanauki.pl/articles/204544.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pył wapienniczy
podatność magnetyczna
metale ciężkie
zakwaszenie
przewodnictwo wlaściwe
lime dust
magnetic susceptibility
heavy metals
acidification
specific conductivity
Opis:
Until now, dust arising from lime manufacture has been considered harmless to the environment so it has been investigated marginally from the standpoint of environmental protection, especially when it came to magnetic properties and heavy metal content. The aim of the research was filling the gap in this area. The research comprised measurements of magnetic susceptibility, the content of heavy metals, reaction (pH) and specific conductivity of lime dust and also raw material and fuel used for lime production. The samples were taken from one of the lime plants located in Opole Province. Similar investigations were also performed for dust taken from the nearby cement plant using dry method of cement production. It was proven that magnetic susceptibility, heavy metal content and conductivity of lime dust was lower in comparison to cement dust, which resulted from the fact that the lime plant used neither low raw materials nor additives. Due to the high atmosphere dust level in the vicinity of the investigated plants, extremely basic reaction of the tested dust and high content of metals, the studied dust cause alkalization of soils and contribute to the increase of heavy metal content in soils, posing a threat to the environment.
Pyły powstające przy produkcji wapna uważane były za nieszkodliwe dla środowiska i w związku z tym były one badane marginalnie, szczególnie jeśli chodzi o właściwości magnetyczne i zawartość metali ciężkich. Celem prezentowanych badań było uzupełnienie luki w tym zakresie. Badania obejmowały pomiary podatności magnetycznej oraz oznaczenia zawartości metali ciężkich, pH i przewodnictwa właściwego pyłów wapienniczych, a także surowca i paliwa, używanego do produkcji wapna. Próbki zostały pobrane w jednym z zakładów wapienniczych województwa opolskiego. Podobne badania wykonano także dla pyłów pobranych w pobliskiej cementowni stosującej suchą metodę produkcji cementu. Wykazano, że podatność magnetyczna, zawartość metali ciężkich i przewodnictwo właściwe pyłów wapienniczych jest niższe w porównaniu do cementowych, co wynikało z faktu, że zakład wapienniczy nie stosował surowców niskich ani dodatków. Z powodu dużego opadu pyłu w rejonie badanego zakładu oraz bardzo wysokiego odczynu pyłów wapienniczych, mogą one powodować alkalizację gleb i przyczyniać się do wzrostu zawartości w nich metali ciężkich, stwarzając zagrożenie dla środowiska.
Źródło:
Archives of Environmental Protection; 2012, 38, 2; 71-80
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short-term changes in specific conductivity in Polish coastal lakes (Baltic Sea basin)
Autorzy:
Cieslinski, R.
Powiązania:
https://bibliotekanauki.pl/articles/48996.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Oceanologii PAN
Tematy:
short-term change
specific conductivity
fluctuation
coastal lake
sea water intrusion
Polish coast
Baltic coast
Lake Gardno
Lake Lebsko
water salinity
wind speed
chemical composition
Źródło:
Oceanologia; 2013, 55, 3
0078-3234
Pojawia się w:
Oceanologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Potential of Sisal Fibre as an Additive in Lightweight Foamed Concrete for Thermal Properties Enhancement
Autorzy:
Mydin, Md Azree Othuman
Powiązania:
https://bibliotekanauki.pl/articles/2201770.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
foamed concrete
thermal properties
conductivity
diffusivity
specific heat
Opis:
Lightweight foamed concrete (LFC) is extremely permeable, and its thermal properties reduce with rising in the number of voids. In turn, to improve its thermal properties, the solid matrix of LFC can be adjusted by incorporating several natural fibers. The influence of sisal fiber in LFC was not investigated before in the current body of knowledge. Hence, there is some ambiguity considering the mechanism by which and the extent to which the sisal fiber can influence LFC thermal properties. Hence, this study concentrates on distinguishing the potential use of sisal fiber in LFC. The purpose of this research is to determine LFC's thermal characteristics when sisal fiber is added. Casting and testing of densities of 800 kg/m3 and 1600 kg/m3 were done. Various weight fractions were employed pertaining to sisal fiber, i.e., 0.15%, 0.30%, 0.45% and 0.60%. The components of thermal properties, which consist of specific heat, thermal conductivity as well as thermal diffusivity were evaluated. To get comparable results, we fixed the water to cement ratio as 0.45 while keeping constant the cement to sand ratio at 1:1.5. It was seen that optimum results were achieved with the addition of 0.45% of sisal fiber with regard to all the thermal characteristics regarded in this exploration. At 0.45% weight fraction about sisal fiber, maximum compaction was achieved with fibers as well as the cementitious matrix, which ensued in good mix uniformity. Beyond the optimum level pertaining to the presence of sisal fiber, it could be seen that fibers would agglomerate and exhibit non-uniform dispersion, which resulted in a decline with regards to the entire thermal characteristics assessed.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 3; 89--97
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermophysical properties of granular food materials
Autorzy:
Vozarova, V.
Powiązania:
https://bibliotekanauki.pl/articles/25505.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
grain
thermal conductivity
granular material
food material
specific heat
food property
seed
Źródło:
International Agrophysics; 2005, 19, 2
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka parametrów termicznych skał osadowych budujących zbiorniki petrogeotermalne w centralnej części Niżu Polskiego
Thermal parameters characteristics of sedimentary rocks forming petrogeothermal reservoirs in the central part of the Polish Lowlands
Autorzy:
Sowiżdżał, A.
Kaczmarczyk, M.
Powiązania:
https://bibliotekanauki.pl/articles/203936.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
EGS
skały osadowe
przewodność ciepła
ciepło właściwe
sedimentary rocks
thermal conductivity
specific heat
Opis:
Artykuł przedstawia wyniki badań termicznych, takich jak pomiar współczynnika przewodności cieplnej oraz ciepła właściwego, wykonanych na próbkach skał osadowych (piaskowce, wapienie, mułowce) pobranych z głębokich otworów wiertniczych zlokalizowanych w centralnej części Niżu Polskiego. Obszar ten, obejmujący swoim zasięgiem rejon niecki mogileńsko-łódzkiej oraz niewielki fragment wału kujawskiego i monokliny przedsudeckiej, został wytypowany jako potencjalna lokalizacja badawcza dla lokalizacji systemów EGS w skałach osadowych. Potencjalnymi zbiornikami energii petrogeotermalnej są głęboko zalegające utwory triasu dolnego i środkowego, dolnego permu lub karbonu. Z utworów tych pobrano próbki skalne i wykonano na nich badania parametrów termicznych. Współczynnik przewodności cieplnej wyznaczony został dla 24 próbek pobranych z sześciu otworów wiertniczych. Wszystkie wartości pomierzone zostały dla próbek suchych, w dwóch kierunkach: prostopadłym i równoległym. Ciepło właściwe wyznaczono dla 20 próbek pobranych z jedenastu otworów wiertniczych. Najwyższe parametry termiczne uzyskano dla skał piaszczystych.
The paper presents the results of thermal analyzes such as thermal conductivity and specific heat, carried out on samples of sedimentary rocks (sandstones, limestones, siltstones) taken from deep boreholes located in the central part of the Polish Lowlands. This area, covers the Mogilno-Łódź Trough region and a small part of the Kujawy Swell and Fore-Sudetic regions, was selected as a potential location for EGS installation in sedimentary rocks. In the selected area, prospects for building closed geothermal systems have been indicated in the Middle Triassic, Lower Triassic, Lower Permian and Carboniferous rocks. Thermal analyzes on the rock samples were performed. Thermal conductivity was designated for 24 samples from six wells. All values were measured for dry samples in two directions: perpendicular and parallel. Specific heat was designated for 20 samples from eleven wells. Sandstones are characterized by a maximum thermal parameters.
Źródło:
Technika Poszukiwań Geologicznych; 2013, R. 52, nr 2, 2; 141-154
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermophysical properties of the Sołtmany meteorite
Autorzy:
Szurgot, M.
Wach, R. A.
Przylibski, T.A.
Powiązania:
https://bibliotekanauki.pl/articles/411496.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Meteorytowe
Tematy:
chondrite
differential scanning calorimetry (DSC)
specific heat capacity
thermal capacity
thermal diffusivity
thermal conductivity
Opis:
Bulk density, porosity and thermophysical properties of the Sołtmany meteorite have been determined. The mean bulk density of the meteorite is 3.475‧103kg/m3, mean bulk density of the crust is 4.3‧103 kg/m3, grain density 3.71‧103 kg/m3, and porosity 6.4 ±} 0.4%. Mean specific heat capacity determined by DSC in temperature range between 223 and 823 K increases from 595 to 1046 J/(kg‧K), and is equal to 728 J/(kg‧K) at room temperature. Specific heat capacity of various samples is in the range 705–769 J/(kg‧K) at room temperature. Thermal capacity of Sołtmany chondrite is equal to 2.53‧106 J/(m3‧K), thermal diffusivity (1.5–1.8)‧10-6 m2/s, and thermal conductivity 3.9–4.5 W‧m–-1‧K-1at room temperature. Differential scanning calorimetry revealed two reversible phase transitions in the Sołtmany’s troilite: α/β transition at 423 K, and β/γ transition at 596.6 K.
Źródło:
Meteorites; 2012, 2, No. 1-2; 53-65
2299-0313
2299-1220
Pojawia się w:
Meteorites
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal properties of nanoliquids prepared on the basis of natural ester modified by nanoparticles TiO2 and C60
Autorzy:
Dombek, G.
Powiązania:
https://bibliotekanauki.pl/articles/97730.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
natural esters
thermal conductivity
viscosity
density
specific heat
high voltage power transformers
heat transfer coefficient
nanoliquids
Opis:
In this paper the results of the researches concerning thermal properties of insulting nanoliquids received on the basis of natural ester, titan dioxide TiO2 and fullerene C60 were presented. Thermal conductivity, viscosity, density and specific heat are these thermal properties. The range of the temperature was changing from 25°C to 80°C. These properties are crucial from the viewpoint of heat transfer coefficient by insulating liquid used in insulating system of power equipment; thus, they influence on temperature distribution inside the equipment. The possibility of receiving steady nanoliquids was also analyzed. The impact of natural ester modification by nanoparticles and surfactant on thermal properties of received nanoliquids was proved.
Źródło:
Computer Applications in Electrical Engineering; 2015, 13; 404-413
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania termofizyczne materiałów zmiennofazowych w aspekcie ich zastosowań w układach do odzysku ciepła odpadowego
Thermo-physical investigations of phase change materials in the aspect of their application in systems of waste heat recovery
Autorzy:
Smusz, R.
Wilk, J.
Tychanicz-Kwiecień, M.
Gil, P.
Bałon, P.
Powiązania:
https://bibliotekanauki.pl/articles/946009.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
materiał zmiennofazowy
ciepło właściwe
przewodność cieplna
dyfuzyjność cieplna
phase change material
specific heat
thermal conductivity
thermal diffusivity
Opis:
W artykule zaprezentowano wyniki badań eksperymentalnych właściwości termofizycznych wybranych materiałów zmiennofazowych PCM (ang. Phase Change Material). Znajomość właściwości cieplnych materiałów zmiennofazowych jest niezbędna przy projektowaniu urządzeń akumulujących ciepło lub układów do odzysku ciepła odpadowego. Opracowywana koncepcja takiego urządzenia pracującego dodatkowo w układzie z odzyskiem ciepła odpadowego była podstawą do prowadzonych badań. W ramach pracy zostały wykonane pomiary przewodności, dyfuzyjności cieplnej, ciepła właściwego oraz gęstości. Badane materiały to: wosk plastyczny, cerezyna niskotopliwa oraz ksylitol i erytrytol. Do badań właściwości cieplnych materiałów zastosowano metodę gorącego drutu.
This paper presents the results of experimental investigation of thermophysical properties of selected phase change materials (PCM). It is essential for design heat-storage devices which utilize such materials. The basis of presented investigation was the concept of heat-storage device in cooperation with waste heat recovery unit. The investigated parameters were: thermal conductivity, diffusivity, specific heat and density. The following materials were tested: plastic wax, ceresin, xylithol and erythritol. Thermophysical parameters were obtained with the use of transient hot wire method. To investigate the thermal properties of materials the hot wire method was used.
Źródło:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika; 2018, z. 90 [298], 1; 67-75
0209-2689
2300-5211
Pojawia się w:
Zeszyty Naukowe Politechniki Rzeszowskiej. Mechanika
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies