Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sound meter" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
Analysis of noise sources and selection of ear protector in a coal mine
Autorzy:
Erol, Ilknur
Su, Okan
Powiązania:
https://bibliotekanauki.pl/articles/2203335.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kopalnia węgla
hałas
dozymetr
coal mine
noise
sound meter
dosimeter
hearing protection device
Opis:
In this study, the noise sources to which a coal miner, who works at the Kurul panel of Kilimli Colliery, Zonguldak, was exposed were investigated. These sources were positioned at different points from the surface to the workface. Noise levels were measured according to the working periods of the coal miners around the machines. The results were evaluated under the Turkish Noise Regulation. The critical exposure times in which the coal miners could work without the use of personal protective equipment were examined according to the noise values to which they were exposed. In addition, the personal noise exposure values of the machine operators (boring machine, electro-hydraulic drill, and pick hammer) were determined during the development works. Two different types of noise measurements, with a microphone at the ear level and inside the ear protector, were conducted. The results obtained when the microphone of the personal dosimeter was at ear level, were found to be 15 dBA higher than those when the microphone was inside the ear protector. As a result, the selection methods of ear protectors were analyzed. Recommendations were given for those working on the risky tasks at the panel.
Źródło:
Archives of Mining Sciences; 2022, 67, 3; 455--476
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accredited Calibration Laboratory for Sound Measurements
Autorzy:
Podgórski, A.
Powiązania:
https://bibliotekanauki.pl/articles/114156.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ISO / IEC 17025 standard
accreditation of calibration laboratory
calibration of sound level meter
acoustic calibrator
band-pass filters
personal sound exposure meter
Opis:
The article presents basic concepts related to accredited calibration laboratories in accordance with ISO/IEC 17025. It describes in detail one of the only few existing in Poland calibration laboratories which deals with instruments for sound measurements. This laboratory is an interesting case as it is the only one in Poland, located in a company developing new instruments, producing, selling them and conducting their service in all over the world. Thanks to this location, the laboratory is able to provide their services not only in Poland but also abroad, which could affect revenues. In the paper laboratory equipment is presented and the innovative ways to increase measurement throughput is discussed. The calibration and measurement capability developed on the basis of uncertainty budgets is given. The activities carried out during the calibration are presented as well as the contents of the first page of the certificate. In the conclusions the strengths of the laboratory are listed.
Źródło:
Measurement Automation Monitoring; 2016, 62, 8; 250-253
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Industrial noise level study in a wheat processing factory in Ilorin, Nigeria
Autorzy:
Ibrahim, I.
Ajao, K. R.
Aremu, S. A.
Powiązania:
https://bibliotekanauki.pl/articles/265416.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
poziom szumów
cyfrowy miernik szumów
hałas
wheat processing
noise level
digital sound meter
questionnaire
hearing protector
Opis:
An industrial process such as wheat processing generates significant noise which can cause adverse effects on workers and the general public. This study assessed the noise level at a wheat processing mill in Ilorin, Nigeria. A portable digital sound level meter HD600 manufactured by Extech Inc., USA was used to determine the noise level around various machines, sections and offices in the factory at pre-determined distances. Subjective assessment was also mode using a World Health Organization (WHO) standard questionnaire to obtain information regarding noise ratings, effect of noise on personnel and noise preventive measures. The result of the study shows that the highest noise of 99.4 dBA was recorded at a pressure blower when compared to other machines. WHO Class-4 hearing protector is recommended for workers on the shop floor and room acoustics should be upgraded to absorb some sounds transmitted to offices.
Źródło:
International Journal of Applied Mechanics and Engineering; 2016, 21, 2; 511-523
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Acoustic Analysis Using Sound Level Meter to Determine the Period of Usage of the Spindle Bearing of a Radial Drilling Machine
Autorzy:
Charles, S.
Vijaya, Joslin D.
Powiązania:
https://bibliotekanauki.pl/articles/176769.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustical condition monitoring
radial drilling machine
spindle bearing
sound level meter
sound pressure level
sound muting transducer
Opis:
The condition monitoring techniques like acoustic emission, vibration analysis, and infrared thermography, used for the failure diagnosis of bearings, require longer processing time, as they have to per form acoustical measurement followed by signal processing and further analysis using special software. However, for any bearing, its period of usage can be easily determined within an hour, by measuring the bearing sound, using sound level meter (SLM). In this paper the acoustical analysis of the spindle Bering of a radial drilling machine was performed using SLM, by measuring the sound pressure level of the bearing in decibels, for different frequencies, while muting all the other noises. Then using an experimental set up, two database readings were taken, one for new bearing and the other for completely damaged bearing, both are SKF6207, which itself is the spindle bearing. From these three sets of sound pressure level readings, the period of usage of the spindle bearing, was calculated using an interpolation equation, by substituting the life of the bearing from the manufacturer’s catalogue. Therefore, for any machine with a SKF6207 bearing, its usage time can be estimated using the database readings and one measurement on that machine, all with the same speed.
Źródło:
Archives of Acoustics; 2019, 44, 3; 505-510
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Noise vulnerability mapping using geospatial technique in part of Ibadan north east local government area
Autorzy:
Oni, Olukunle O.
Adetimirin, O. I.
Ajibade, S. A.
Kolade, K. R.
Ilesanmi, O. I.
Akinluyi, F. O.
Powiązania:
https://bibliotekanauki.pl/articles/1189960.pdf
Data publikacji:
2016
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Digital Sound Level Meter (DSLM)
Inverse Distance Weighted (IDW)
Mean Noise Level
Noise Level Point
and Sound Level for Morning
Afternoon and Evening (Lm_a_e)
Opis:
Human activity is main source of all environmental pollutions. Noise is common environmental issuesthat cannot be generated without geospatial location. It has great impact on mankind such as physical disturbance, physiological disturbance and affects human health. The aim of this research work is to identify the geospatial noise level and mapping noise vulnerability in some part of Ibadan North East Local Government Area. DSLM and GPS are used for survey method in which sixteen different location points were selected for noise vulnerability. The Mathematical Model is used to calculate Equivalent continuous sound level for morning, afternoon and evening (Lm_a_e), mean noise level for the morning, afternoon, evening and Daily Average of Noise values were generated. World Health Organization (WHO) recommendation standard was used as a standard in this research because Nigeria Noise pollution bill is still under consideration in the National Assembly. ArcGIS software was used for analysis and noise zones were carved out based on WHO yardsticks. Noise vulnerability mapping generated shown that land uses within the study area were experiencing very higher noise levels which are risky to the environment and society. Environmental agency and Government should set standard values for the noise barriers by passing the noise bill in the National Assembly assiduously and soonest.
Źródło:
World Scientific News; 2016, 52; 143-161
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies