Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "solar analysis" wg kryterium: Temat


Tytuł:
Semantic hashing for fast solar magnetogram retrieval
Autorzy:
Grycuk, Rafał
Scherer, Rafał
Marchlewska, Alina
Napoli, Christian
Powiązania:
https://bibliotekanauki.pl/articles/2147145.pdf
Data publikacji:
2022
Wydawca:
Społeczna Akademia Nauk w Łodzi. Polskie Towarzystwo Sieci Neuronowych
Tematy:
content-based image retrieval
image descriptor
solar analysis
Opis:
We propose a method for content-based retrieving solar magnetograms. We use the SDO Helioseismic and Magnetic Imager output collected with SunPy PyTorch libraries. We create a mathematical representation of the magnetic field regions of the Sun in the form of a vector. Thanks to this solution we can compare short vectors instead of comparing full-disk images. In order to decrease the retrieval time, we used a fully-connected autoencoder, which reduced the 256-element descriptor to a 32-element semantic hash. The performed experiments and comparisons proved the efficiency of the proposed approach. Our approach has the highest precision value in comparison with other state-of-the-art methods. The presented method can be used not only for solar image retrieval but also for classification tasks.
Źródło:
Journal of Artificial Intelligence and Soft Computing Research; 2022, 12, 4; 299--306
2083-2567
2449-6499
Pojawia się w:
Journal of Artificial Intelligence and Soft Computing Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza solarna budynków w celu zwiększenia efektywności energetycznej
Autorzy:
Sobierajewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/162936.pdf
Data publikacji:
2011
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
energia słoneczna
efektywność energetyczna
Polska
analiza solarna
schemat zacienienia
solar energy
energy efficiency
Polska
solar analysis
shading chart
Źródło:
Przegląd Budowlany; 2011, R. 82, nr 9, 9; 82-88
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A comprehensive review on energy and exergy analysis of solar air heaters
Autorzy:
Ghritlahre, Harish Kumar
Sahu, Piyush Kumar
Powiązania:
https://bibliotekanauki.pl/articles/240351.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
solar energy
energy
exergy analysis
solar air heater
thermal performance
Opis:
For economic growth of nation, the energy plays an important role. The excessive use of fossil fuels results the increase in global warming and depleting the resources. Due to this reason, the renewable energy sources are creating more attraction for researchers. In renewable energy sector, solar energy is the most abundant and clean source of energy. In solar thermal systems, solar air heater (SAH) is the main system which is used for heating of air. As it is simple in construction and cheaper in cost, it is of main interest for the researchers. The concept of first law and second law of thermodynamics is used for the study of the energy and exergy analysis respectively. The energy analysis is of great importance for the study of process effectiveness while the exergetic analysis is another significant concept to examine the actual behavior of process involving various energy losses and internal irreversibility. For efficient utilization of solar energy, the exergy analysis is very important tool for optimal design of solar air heaters. The aim of the present work is to review the works related to energy and exergy analysis of various types of solar air heaters and to find out the research gap for future work.
Źródło:
Archives of Thermodynamics; 2020, 41, 3; 183-222
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An experimental study of solar air heater using arc shaped wire rib roughness based on energy and exergy analysis
Autorzy:
Ghritlahre, Harish Kumar
Powiązania:
https://bibliotekanauki.pl/articles/1955008.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
artificial roughness
energy analysis
exergy analysis
solar air heater
Opis:
In the present study, energy and exergy analysis has been evaluated for roughened solar air heater (SAH) using arc shaped wire ribs. To achieve this aim, two different types of flow arrangement have been considered. These arrangements are: apex upstream flow and apex downstream flo. In addition to this, a smooth duct SAH has been used for comparative study. The experiments were performed using the mass flow rate of 0.007– 0.022 kg/s on outdoor condition at Jamshedpur city of India. The absorber plate roughness geometry has been designed with relative roughness height 0.0395, rib size 2.5 mm, relative roughness pitch 10 and arc angle 60◦ . The energetic and exergetic performances have been examined on the basis of the first and second law of thermodynamics. According to the results, there is observed to be the maximum thermal efficiency and exergy efficiency as 73.2% and 2.64%, respectively, for apex upstream flow SAH at 0.022 kg/s, while, at same mass flow rate the maximum thermal efficiency and exergy efficiency is obtained as 69.4% and 1.89%, respectively, for apex downstream flow SAH. In addition to this, results reported that the maximum outlet temperature and temperature difference observed at lower mass flow rate. Also examined the outlet air temperature of SAH with various mass flow rates is very important for both analysis.
Źródło:
Archives of Thermodynamics; 2021, 42, 3; 115-139
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency analysis of flat and vacuum solar collector systems
Analiza efektywnosci energetycznej plaskich i podcisnieniowych ukladow kolektora slonecznego
Autorzy:
Kurpaska, S.
Latala, H.
Knaga, J.
Powiązania:
https://bibliotekanauki.pl/articles/791882.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
energy efficiency
analysis
vacuum solar collector
flat solar collector
solar collector
heat pump
solar radiation
conversion efficiency
renewable energy source
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Savitzky-Golay method for power output data set
Autorzy:
Gulkowski, S.
Powiązania:
https://bibliotekanauki.pl/articles/1940714.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska
Tematy:
photovoltaics
solar energy
time series
PV data analysis
Opis:
The power output of a PV system changes in time during the day and strongly depends on the location and orientation of the photovoltaic module as well as on seasonal conditions. Clouds occurring during a partly cloudy day are the reason why this data is very irregular and difficult to analyze in terms of obtaining energy. The Savitzky-Golay method was applied for the power output data obtained for sunny, cloudy and partly cloudy days in order to determine the average level of power produced by a PV system at a given location. The total amount of energy was analyzed for each case.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2015, 19, 1; 25-34
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smart Cooling Controlled System Exploiting Photovoltaic Renewable Energy Systems
Autorzy:
Atieh, A.
Al Asfar, J.
Tawalbeh, N.
Shaqour, E.
Alsalhi, I.
Istaiteh, O.
Powiązania:
https://bibliotekanauki.pl/articles/123359.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
smart cooling system
solar system
energy management
cost analysis
Opis:
A smart cooling system to control the ambient temperature of a premise in Amman, Jordan, is investigated and implemented. The premise holds 650 people and has 14 air conditioners with the cooling capacity ranging from 3 to 5 ton refrigerant (TR) each. The control of the cooling system includes implementing different electronics circuits that are used to sense the ambient temperature and humidity, count the number of people in the premise and then turn ON/OFF certain air conditioner(s). The data collected by different electronic circuits are fed wirelessly to a microcontroller, which decides which air conditioner will be turned ON/OFF, its location and its desired set cooling temperature. The cooling system is integrated with an on-grid solar photovoltaic energy system to minimize the operational cost of the overall cooling system.
Źródło:
Journal of Ecological Engineering; 2018, 19, 2; 39-44
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza eksploatacyjna instalacji słonecznej pracującej na potrzeby przygotowania c.w.u. dla budynku wielorodzinnego
Analysis of use of solar panel installations heat water for the needs of inhabitants of the multifamily building
Autorzy:
Babiarz, B.
Borkowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/104522.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
eksploatacja
instalacja słoneczna
kolektor słoneczny
koszty
analiza
serwisowanie
use
solar panel installation
solar collector
costs
analysis
Opis:
Celem niniejszej pracy jest przeprowadzenie analizy instalacji słonecznych pod kątem eksploatacyjnym. Zasadniczą część opracowania stanowi analiza istniejącej od 2005 r. instalacji słonecznej pracującej dla potrzeb przygotowania ciepłej wody użytkowej dla mieszkańców budynku wielorodzinnego. W pracy wykorzystano rzeczywiste dane eksploatacyjne z dziesięciu lat działania instalacji, udostępnione przez Spółdzielnię Mieszkaniową „ZODIAK” w Rzeszowie. Przeanalizowano koszty przygotowania ciepłej wody użytkowej oraz koszty serwisowe instalacji. Na koszty eksploatacyjne instalacji słonecznych składają się m.in.: koszty zużycia i przygotowania c.w.u., koszty zużycia energii elektrycznej przez pompy obiegowe instalacji słonecznych, oraz koszty serwisowania instalacji. Na podstawie niniejszej analizy można wysnuć szereg wniosków możliwych do wykorzystania w analizach techniczno-finansowych na etapie projektowania inwestycji w odnawialne źródła energii. Przeprowadzona analiza wykazała, iż instalacja słoneczna w znacznym stopniu obniża koszty przygotowania ciepłej wody użytkowej. Koszt przygotowania 1 m3 ciepłej wody użytkowej w analizowanym budynku wielorodzinnym w 2015 r. przy udziale instalacji słonecznej stanowił 67% kosztów podgrzewu ciepłej wody w budynku o podobnej kubaturze wykorzystującym ciepło z miejskiej sieci ciepłowniczej. Pompy obiegowe zastosowane w instalacjach słonecznych charakteryzują się stosunkowo małym zużyciem energii elektrycznej. Koszty serwisowe instalacji są niewielkie i zależą od wielkości instalacji, jej lokalizacji oraz budowy.
The purpose of this work was to analyzed the use of solar panel installations. In the thesis was evaluated performance of solar panel installation located in Rzeszow. In thesis used real data of ten years operation provided by Housing Association “ZODIAK” Rzeszow. This installation prepares water for the needs of inhabitants. Costs of preparing domestic hot water and service operations have been analyzed. Energy consumption by circulating solar pumps was determined. The costs of using of solar installations consist of among other: costs consumption and prepare domestic hot water, the cost of electricity consumption by circulating solar pumps, and service operations. On the basis of the following analysis can be draw conclusions which can be used in technical and financial analysis at the design stage investments in renewable energy sources. This analysis showed that solar installations reduce the cost of domestic hot water. The cost of preparing one cubic meter domestic hot water for the analyzed installations located in King Augusta Street in Rzeszow in 2015 was about 67% lower than in the case of a building with a similar size which supply of district heating. Costs of service operations of solar installations are small and depend on the size of the installation, construction, location and the way of using solar installations. Circulating solar pumps are characterized by low energy consumption. Regular service can help to reduce costs of solar installations and extend the working life of installations.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 1; 431-440
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multi-criteria analysis for solar farm location suitability
Autorzy:
Mierzwiak, M.
Calka, B.
Powiązania:
https://bibliotekanauki.pl/articles/106711.pdf
Data publikacji:
2017
Wydawca:
Politechnika Warszawska. Wydział Geodezji i Kartografii
Tematy:
solar farm
Multi-Criteria Decision Analysis
spatial analysis
farma słoneczna
analiza wielokryterialna
analiza przestrzenna
Opis:
Currently the number of solar farms, as a type of renewable sources of energy, is growing rapidly. Photovoltaic power stations have many advantages, which is an incentive for their building and development. Solar energy is readily available and inexhaustible, and its production is environmentally friendly. In the present study multiple environmental and economic criteria were taken into account to select a potential photovoltaic farm location, with particular emphasis on: protected areas, land cover, solar radiation, slope angle, proximity to roads, built-up areas, and power lines. Advanced data analysis were used because of the multiplicity of criteria and their diverse influence on the choice of a potential location. They included the spatial analysis, the Weighted Linear Combination Technique (WLC), and the Analytic Hierarchy Process (AHP) as a decision-making method. The analysis was divided into two stages. In the first one, the areas where the location of solar farms was not possible were excluded. In the second one, the best locations meeting all environmental and economic criteria were selected. The research was conducted for the Legionowo District, using data from national surveying and mapping resources such as: BDOT10k (Database of Topographic Objects), NMT (Numerical Terrain Model), and lands and buildings register. Finally, several areas meeting the criteria were chosen. The research deals with solar farms with up to 40 kW power. The results of the study are presented as thematic maps. The advantage of the method is its versatility. It can be used not only for any area, but with little modification of the criteria, it can also be applied to choose a location for wind farms.
Źródło:
Reports on Geodesy and Geoinformatics; 2017, 104; 20-32
2391-8365
2391-8152
Pojawia się w:
Reports on Geodesy and Geoinformatics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of Polish patent applications in the solar energy technology with the use of text mining methodology
Autorzy:
Bęben, Karolina
Nowakowska, Marzena
Powiązania:
https://bibliotekanauki.pl/articles/27313482.pdf
Data publikacji:
2022
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
solar energy patent analysis
patent documents processing
patent clustering
outliers detection
Polish Patent Office
analiza patentowa energii słonecznej
przetwarzanie dokumentów patentowych
grupowanie patentów
wykrywanie wartości odstających
Urząd Patentowy RP
Opis:
Purpose: Knowledge management belongs to the most important elements of organisational management, including manufacturing enterprises. Patent information plays an increasingly important role in this area. Identification of the main directions of invention activity may inspire new product and process ideas, and can help to improve existing solutions. The above is particularly important in the energy sector, which is currently struggling with increasing problems. In this context, solar energy is the subject of interest to inventive communities. The paper discusses patent applications related to solar energy, taking up the task of discovering the main tendencies of technological solutions in this area. Design/methodology/approach: In the work, a pilot study of the research aimed to indicate the directions of technological development in the field in Poland was undertaken. Shortened descriptions of selected patent documents from the Polish Patent Office (PPO) were the subject of the investigation. The descriptions were reduced to the form of a vector space model by using text mining tools. The exploration of such prepared data was done applying unsupervised text mining techniques. Hierarchical cluster analysis enabled the identification of groups of similar inventions. An algorithm to detect outliers within individual patent groups was also developed and applied. Findings: Five patent clusters were identified covering the following thematic areas: PV panel designs, PV panel component designs, the improvement of solar-heat conversion device performance, and solar collector designs. Six patent applications stood out thematically in four of the five clusters. Research limitations/implications: The research is limited to a selected number of patent documents form PPO. However, the presented method and research area are promising. It is planned to extend the analyses to a larger set of patent documents and solve the problem related to the language uniformity of patent applications along with merging data from various sources. In this aspect, a full patent description will be consider as well. Originality/value: In relation to solar energy issues, main patent areas and patent outliers that may be indicators of special interests of inventors were identified. In relation to methodology issues, new solutions within consecutive research steps were proposed.
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2022, 162; 9--34
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimising the selection of batteries for photovoltaic applications
Optymalizacja doboru akumulatorow do zastosowan fotowoltaicznych
Autorzy:
Knaga, J.
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/792139.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
battery capacity
autonomous solar system
photovoltaic module
photovoltaic system
solar radiation energy
polycrystalline structure
analysis
meteorological station
calculation
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Complex trapezoid grating for light trapping in thin-film solar cells: super-fine structure
Autorzy:
Fang, Junfei
Gou, Yuchun
Deng, Jianping
Powiązania:
https://bibliotekanauki.pl/articles/1835802.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
light trapping
complex trapezoid grating
rigorous coupled-wave analysis
solar cell
Opis:
The research of the optimal surface structure has attracted considerable interest because of its potential application in light trapping in thin-film solar cells (TFSCs). In this paper, a super-fine structure named complex trapezoid grating is proposed to improve the optical absorption comparing to the conventional simple trapezoid grating in a-Si:H TFSCs. The numerical calculation by utilizing rigorous coupled-wave analysis (RCWA) is conducted to obtain the optical absorption of the structured surface. The results demonstrate that, compared to a planar slab, the optimized-simple trapezoid grating shows 97% enhancement of power conversion efficiency η while the complex trapezoid grating shows 131% enhancement. Obviously, the complex trapezoid grating exhibits a better performance than the simple grating, which is due to the perfect antireflective effect and microcavity resonance effect. The angular response of the optical absorption in a-Si:H TFSCs was also investigated. The results further indicate that it is a better way to select the complex trapezoid grating in improving the optical absorption of silicon-based TFSCs.
Źródło:
Optica Applicata; 2020, 50, 3; 391-400
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergy analysis of double-circuit flat solar collector with thermosyphon circulation
Analiza egzergetyczna kolektora słonecznego dwuobwodowego z obiegiem termosyfonu
Autorzy:
Wójcik, Waldemar
Kalimoldayev, Maksat
Amirgaliyev, Yedilkhan
Kunelbayev, Murat
Kalizhanova, Aliya
Kozbakova, Ainur
Merembayev, Timur
Powiązania:
https://bibliotekanauki.pl/articles/408460.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
temperature
solar energy
analysis
mathematical model
temperatura
energia słoneczna
analiza
model matematyczny
Opis:
In the present work, an exergy analysis was done of two-circuit flat solar collector with thermosiphon circulation. The article presents a mathematical model of energy and exergic analysis of flat solar collectors, as well as calculations of solar radiation efficiency, temperature, flow rate of the fluid, exergy rates and exergy loss rates are done. The significance of the results achieved is high, since experimental studies can detect inefficient components of the solar heating system. The exergetic efficiency of a dual-circuit flat solar collector with a thermosiphon circulation describes irreversibility of the process according to thermodynamic parameters. This is caused by a large the degree of overheating achieved at the end of the processes of compression and evaporation, which leads to large differences in heat exchange temperature based on the heat pump cycle. The exergy efficiency value for the entire system is 70. Maximum values energy efficiency and exergy at noon, 32.5% and 2.23%, respectively. The efficiency of exergy is 4%, and the highest the loss of exergy is the difference between the absorber plates and the sun, accounting for 52.86% of the total exergy rate.
W niniejszej pracy wykonano analizę egzergetyczną płaskiego kolektora słonecznego dwuobwodowego z cyrkulacją termosyfonową. W artykule przedstawiono model matematyczny analizy energetycznej i egzergetycznej płaskich kolektorów słonecznych, a także obliczono sprawność promieniowania słonecznego, temperaturę, natężenie przepływu cieczy, wskaźniki egzergii i wskaźniki strat egzergetycznych. Znaczenie osiągniętych wyników jest duże, ponieważ badania eksperymentalne mogą wykryć nieefektywne elementy systemu ogrzewania energią słoneczną. Egzergetyczna sprawność dwuobwodowego płaskiego kolektora słonecznego z obiegiem termosyfonowym opisuje nieodwracalność procesu według parametrów termodynamicznych. Jest to spowodowane dużym stopniem przegrzania osiąganym pod koniec procesów sprężania i odparowywania, co prowadzi do dużych różnic w wymianie ciepła w oparciu o cykl pompy ciepła. Efektywność energetyczna całego systemu wynosi 70. Maksymalne wartości sprawności energetycznej i egzergii w południe, odpowiednio 32,5% i 2,23%. Efektywność egzergii wynosi 4%, a największą stratą egzergii jest różnica pomiędzy płytami absorbera a słońcem, stanowiąca 52,86% całkowitego wskaźnika egzergii.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 3; 35-39
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical simulation and experimental validation of solar greenhouse dryer using finite element analysis for different roof shapes
Autorzy:
Yadav, Aditya Arvind
Prabhu, Pravin A.
Bagi, Jaydeep S.
Powiązania:
https://bibliotekanauki.pl/articles/1819128.pdf
Data publikacji:
2021
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
solar greenhouse dryer
drying
moisture removal
solar thermal energy
finite element analysis
szklarnia
suszarnia słoneczna
suszenie
usuwanie wilgoci
energia słoneczna
analiza elementów skończonych
Opis:
The present study focuses on the numerical simulation and experimental validation of a Solar Greenhouse Dryer (SGHD). The Solar Dryers are the devices which uses solar energy to dry substances, especially crops with high moisture content, and the word Greenhouse means protection of crops from excess hot or cold climatic conditions and unwanted pests. Thus, Solar Greenhouse Dryer is a device which utilizes solar energy for drying of crops with high moisture content and prevents it from excess climatic conditions and provides optimum range of temperature and prevents the dried product from pests and dust while drying. The numerical simulation of SGHD was performed using Finite Element Analysis software ANSYS 2020 R2. Initially three different roof shapes were modelled using software CATIA V5 R3 namely triangular, trapezoidal and dome shape. The modelled SGHDs was then introduced to ANSYS domain for numerical analysis. The models were initially meshed in ANSYS workbench with unstructured tetrahedral structure of mesh over all the domains. The Solar Ray tracing content was used for numerical simulation of dryers, the solar ray tracing is used to predict direct illumination energy source produced by sun at experimental site. The experiment for no-load test was conducted at Bahe Borgaon, Dist- Sangli, Maharashtra, India at 17.115°N and 74.33°E.
Źródło:
Journal of Mechanical and Energy Engineering; 2021, 5, 1; 69--80
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the influence of variable insulating power of a storing tank on energy effects in the conversion system of solar radiation
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/793373.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
solar collector
heat pump
storing tank
insulation
solar radiation
conversion
hybrid system
thermal balance
energy stream
water temperature
daily change
heat balance
analysis
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies