Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "soft X-ray" wg kryterium: Temat


Wyświetlanie 1-12 z 12
Tytuł:
Investigation of low-temperature plasmas formed in low-density gases surrounding laser-produced plasmas
Autorzy:
Majszyk, Mateusz
Bartnik, Andrzej
Skrzeczanowski, Wojciech
Fok, Tomasz
Węgrzyński, Łukasz
Szczurek, Mirosław
Fiedorowicz, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/2202566.pdf
Data publikacji:
2023
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
extreme ultraviolet
EUV
laser plasma
low pressure
photoionization
plasma
soft X-ray
SXR
Opis:
Low-temperature plasma production is possible as a result of photoionization using high-intensity extreme ultraviolet (EUV) and soft X-ray (SXR) pulses. Plasma of this type is also present in outer space, e.g., aurora borealis. It also occurs when high-velocity objects enter the atmosphere, during which period high temperatures can be produced locally by friction. Low-temperature plasma is also formed in an ambient gas surrounding the hot laser-produced plasma (LPP). In this work, a special system has been prepared for investigation of this type of plasma. The LPP was created inside a chamber fi lled with a gas under a low pressure, of the order of 1–50 mbar, by a laser pulse (3–9 J, 1–8 ns) focused onto a gas puff target. In such a case, the SXR/EUV radiation emitted from the LPP was partially absorbed in the low-density gas. In this case, high- and low-temperature plasmas (Te ~100 eV and ~1 eV, respectively) were created locally in the chamber. Investigation of the EUV-induced plasmas was performed mainly using spectral methods in ultraviolet/visible (UV/VIS) light. The measurements were performed using an echelle spectrometer, and additionally, spatial–temporal measurements were performed using an optical streak camera. Spectral analysis was supported by the PGOPHER numerical code.
Źródło:
Nukleonika; 2023, 68, 1; 11--17
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elementy optyczne pracujące w widmowym zakresie obejmującym ultrafiolet próżniowy i miękkie promieniowanie rentgenowskie
Optical elements for the extreme ultraviolet and soft X-ray range
Autorzy:
Wardzińska, Martyna
Wachulak, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/2203159.pdf
Data publikacji:
2022
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
automatyka
elektronika i elektrotechnika
optyka rentgenowska
filtry optyczne
zwierciadła wielowarstwowe
siatki dyfrakcyjne
płytki strefowe Fresnela
ultrafiolet próżniowy
miękkie promieniowanie rentgenowskie
automation
electronic and electrical engineering
soft X-ray
extreme ultraviolet
optical elements
optical filters
multilayer mirrors
diffraction gratings
Fresnel zone plates
Opis:
W artykule zawarto podstawy fizyczne i przegląd elementów optycznych do pracy w zakresie obejmującym ultrafiolet próżniowy (eUV) oraz miękkie promieniowanie rentgenowskie (SXr). Pierwszy rozdział obejmuje wprowadzenie do analizowanej tematyki i podstawy fizyczne. W drugim rozdziale przedstawione zostały podstawy działania optyki związanej z zakresem eUV/SXr wraz z wyróżnieniem jej wad oraz zalet. W trzecim rozdziale szczegółowo omówiono elementy optyczne, takie jak: filtry optyczne, zwierciadła (m.in. wielowarstwowe), siatki dyfrakcyjne, płytki strefowe Fresnela oraz rozwiązania hybrydowe. rozdział czwarty przedstawia szeroki obszar zastosowań optyki eUV/SXr. W ostatnim rozdziale znajduje się podsumowanie przedstawionych wcześniej informacji.
The article presents the physical basis and overview of optical elements for the range including extreme ultraviolet (eUV) and soft X-ray (SXr). The first chapter contains an introduction to the subject under review and physical fundamentals. The second chapter presents the basics of optics for the eUV/SXr range, along with highlighting its advantages and disadvantages. The third chapter discusses in detail optical components such as optical filters, mirrors (including multilayers), diffraction gratings, Fresnel zone plates, and hybrid solutions. The fourth chapter presents a wide range of applications of eUV/SXr optics. The final chapter summarises the information presented earlier.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2022, 71, 2; 49--83
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wideband spectral emission measurements from laser-produced plasma EUV/SXR source based on a double gas puff target
Autorzy:
Arikkatt, Antony Jose
Wachulak, Przemysław
Fiedorowicz, Henryk
Bartnik, Andrzej
Czwartos, Joanna
Powiązania:
https://bibliotekanauki.pl/articles/1849155.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Plasma Spectroscopy
X-ray coherence tomography
soft X-ray
Opis:
We present spectral emission characteristics from laser-plasma EUV/SXR sources produced by irradiation of < 1 J energy laser pulse on eleven different double stream gas puff targets, with most intense electronic transitions identified in the spectral range from 1 nm to 70 nm wavelength which corresponds to photon energy from 18 eV to 1240 eV. The spectra were obtained using grazing incidence and transmission spectrographs from laser-produced plasma emission, formed by the interaction of a laser beam with a double stream gas puff target. Laser pulses with a duration of 4 ns and energy of 650 mJ were used for the experiment. We present the results obtained from three different spectrometers in the wavelength ranges of SXR (1-5.5 nm), SXR/EUV (4-15.5 nm), and EUV (10-70 nm). In this paper, detailed information about the source, gas targets under investigation, the experimental setup, spectral measurements and the results are presented and discussed. Such data may be useful for the identification of adequate spectral emissions from gasses in the EUV and SXR wavelength ranges dedicated to various experiments (i.e. broadband emission for the X-ray coherence tomography XCT) or may be used for verification of magnetohydrodynamic plasma codes.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 701-719
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie parametrów ekspozycji do zdjęcia klatki piersiowej dorosłych pacjentów przyjętych na oddział ratunkowy Szpitala Uniwersyteckiego w Krakowie z parametrami zawartymi w Procedurach Wzorcowych (Prawo atomowe – Dz.U. z 2014 r.)
Comparison of exposure parameters to chest X-ray of adult patients admitted to the emergency department of the University Hospital in Cracow with the parameters contained in the Standard Protocols (Atomic Law in Official Journal of 2014)
Autorzy:
Mizgalska-Traczyk, Halina
Borkowska, Eliza
Malisz, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/985869.pdf
Data publikacji:
2019
Wydawca:
Indygo Zahir Media
Tematy:
radiologiczne procedury wzorcowe
zdjęcia klatki piersiowej
technika twardego promieniowania
technika miękkiego promieniowania
the reference radiological procedures
chest X-ray
hard radiation technique
soft radiation technique
Opis:
Zdjęcie klatki piersiowej jest podstawowym zdjęciem w diagnostyce obrazowej, jednym z najczęściej wykonywanych, a niezbędnym u pacjentów przyjętych na szpitalny oddział ratunkowy. Wzorcowe procedury radiologiczne opublikowane w Dz. Urz. Ministra Zdrowia z 2014 poz. 85 zobowiązują personel medyczny do wykonywania przeglądowego badania rentgenowskiego klatki piersiowej zgodnie z przyjętymi standardami wykonawczymi, aby zminimalizować możliwe skutki niepożądane związane z promieniowaniem jonizującym. W ramach prowadzonego audytu wykazano, że 67% badań przeglądowych klatki piersiowej wykonano według standardu techniką twardego promieniowania w pozycji stojącej w rzucie PA, natomiast 33% wykonano miękką falą w pozycji AP na leżąco. W niniejszym opracowaniu autorzy proponują zmianę podejścia techników elektroradiologii do wyboru parametrów ekspozycji u pacjentów diagnozowanych w ciężkich stanach w szpitalnych oddziałach ratunkowych i zastosowanie do zdjęć klatki piersiowej u tych pacjentów techniki twardego promieniowania zgodnie z zaleceniami zawartymi we wzorcowych procedurach radiologicznych. Technikę obniżonego napięcia stosować przy wykonywaniu zdjęcia przyłóżkowego u pacjentów hospitalizowanych lub w sytuacjach, kiedy stosowanie twardego promieniowania z powodów technicznych w pracowni RTG jest niemożliwe.
Chest X-ray is a basic diagnostic image, one of the most frequently performed on patients admitted to the hospital emergency department. The reference radiological procedures published by the Minister of Health in 2014 obliges medical personnel to perform a chest X-ray examination in accordance with the adopted executive standards in order to minimize possible adverse effects connected with ionizing radiation. An audit demonstrated that 67% of chest examinations were made according to the standard, using a hard radiation technique in the standing PA view, while 33% were performed in a soft radiation technique AP in a lying position. In this study the authors suggest to change the approach of X-ray technicians to the choice of exposure parameters in the case of patients with severe conditions in hospital emergency departments and use hard radiation techniques for chest images in the case of these patients in accordance with the recommendations in the reference radiological procedures. The technique of reduced voltage should be used during bedside examinations in the case of hospitalized patients or in situations where it is not possible to use hard radiation in an X-ray department for technical reasons.
Źródło:
Inżynier i Fizyk Medyczny; 2019, 8, 5; 373-377
2300-1410
Pojawia się w:
Inżynier i Fizyk Medyczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multiboard trigger link synchronization and diagnostics
Autorzy:
Wojenski, A.
Pozniak, K.
Mazon, D.
Chernyshova, M.
Powiązania:
https://bibliotekanauki.pl/articles/114174.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
data quality monitoring
FPGA
GEM detector
soft X-ray plasma diagnostics
trigger distribution
measurement system
Opis:
Soft X-ray (SXR) plasma measurements are important type of diagnostics especially in tokamak facilities. Main output products are energy and topology spectra distributed in time. In case of Gas Electron Multiplier (GEM) detectors, used as radiation sensors, large number of analog readout channels must be provided. For this purpose Field-Programmable Gate Arrays (FPGAs) are used. Data quality monitoring (DQM) is important topic in case of asynchronous events registered by the measurement unit. Due to numerous FPGAs used it is necessary to provide advanced trigger synchronization between them. In the paper is proposed an algorithmic approach for the trigger link training and diagnostics. It is a key component in order to provide consistent measurement data for DQM analysis. The contents of the article covers the plasma experiments and related DQM topics. In following chapters explanation of the synchronization problem is described. The proposed algorithm will be used for trigger link synchronization and diagnostics aspects. The simulations are also discussed. Currently, the proposed ideas are at the stage of implementation and tests on real hardware. Simulation were successfully performed. Summary of the work carried out is presented at the end of the paper.
Źródło:
Measurement Automation Monitoring; 2017, 63, 6; 223-225
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of soft X-ray tomography on the COMPASS tokamak
Autorzy:
Imríšek, M.
Mlynář, J.
Löffelmann, V.
Weinzettl, V.
Odstrčil, T.
Odstrčil, M.
Tomeš, M.
Powiązania:
https://bibliotekanauki.pl/articles/146251.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
soft X-ray
tomography
Tikhonov regularization
tokamak
Opis:
The COMPASS tokamak is equipped with the soft X-ray (SXR) diagnostic system based on silicon photodiode arrays shielded by a thin beryllium foil. The diagnostic is composed of two pinhole cameras having 35 channels each and one vertical pinhole camera with 20 channels, which was installed recently to improve tomographic inversions. Lines of sight of the SXR detectors cover almost complete poloidal cross section of the COMPASS vessel with a spatial resolution of 1–2 cm and temporal resolution of about 3 s. Local emissivity is reconstructed via Tikhonov regularization constrained by minimum Fisher information that provides reliable and robust solution despite limited number of projections and ill-conditionality of this task. Improved border conditions and numerical differentiation matrices suppressing artifacts in reconstructed radiation were implemented in the code. Furthermore, a fast algorithm eliminating iterative processes was developed, and it is foreseen to be tested in real-time plasma control.
Źródło:
Nukleonika; 2016, 61, 4; 403-408
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Second order reflection from crystals used in soft X-ray spectroscopy
Autorzy:
Książek, I.
Powiązania:
https://bibliotekanauki.pl/articles/146093.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
soft X-ray
plasma spectroscopy
PbSt
KAP
Opis:
In this note the ratio of the second to the first order reflection is determined for the KAP and PbSt crystals, for wavelengths corresponding to the Al K-line emission. The source of the radiation was a low-voltage stabilized X-ray tube. The X-rays were detected with a Bragg spectrometer equipped with a proportional counter detector. The signal measured by the proportional counter was subsequently pulse height analyzed.
Źródło:
Nukleonika; 2015, 60, 2; 263-265
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conceptual design of Light Impurity Monitor for Wendelstein 7-X
Autorzy:
Książek, I.
Burhenn, R.
Musielok, J.
Powiązania:
https://bibliotekanauki.pl/articles/146640.pdf
Data publikacji:
2011
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma spectroscopy
stellarator
soft X-ray
Opis:
As plasma impurity ions can significantly influence the properties of a fusion plasma by dilution and enhancement of the radiation losses, the process of monitoring of their concentrations is one of the most important tasks. A Light Impurity Monitor is needed for monitoring the contamination of the stellarator plasma by carbon, nitrogen, boron, and oxygen impurities, which are indicators for the overload of the plasma facing components, leakage of the vacuum vessel, or wall condition, respectively. Their concentration will be estimated on the basis of emission intensities of their hydrogen-like ions. In this paper a conceptual design of such a spectrometer is presented, including the description of the geometry, the acquisition system and safety systems.
Źródło:
Nukleonika; 2011, 56, 2; 155-160
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
0.2-kJ and 2-kJ high rep rate Dense Plasma foci : their design, technology, and applications
Autorzy:
Dubrovsky, A. V.
Gribkov, V. A.
Ivanov, Y. P.
Lee, P.
Lee, S.
Liu, M.
Samarin, V. A.
Powiązania:
https://bibliotekanauki.pl/articles/146546.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
dense plasma focus (DPF)
DPF installation
miniature focus chamber
soft and hard X-ray radiation
Opis:
The paper presents various designs of several medium and small size Dense Plasma Focus (DPF) chambers intended for numerous applications, a description of technologies used in these facilities, and some results reached with these devices by using a number of diagnostic techniques. In present experiments the DP foci have been used mainly as an X-ray source. We discuss here how it is possible to satisfy absolutely new and very strict demands on the construction and technology for the devices to be eventually applied in science and industry. Between these characteristics there are a high repetition rate (typically 1…15 Hz) and a long lifetime (over 1 million shots). Their switching elements, a collector and chambers must withstand a high quasi-continuous heat load (up to 100 kW). High energy density in the central part of the chamber anode and the necessity to provide a channel for radiation extraction demanded a special construction and specific materials implementation in this region. Their X-ray spectrum should be tuned. They have to operate with different working gases and preferably in a wide range of pressures. All these points are discussed in this report. Capabilities of the described techniques are illustrated by results of the recent experimental studies carried out with facilities located at the Nanyang Technological University (NX1) as well as at the Lebedev Physical Institute (PF-0.2).
Źródło:
Nukleonika; 2001, 46, suppl. 1; 107-111
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent progress in 1 MJ Plasma-Focus research
Autorzy:
Scholz, M.
Karpiński, L.
Paduch, M.
Tomaszewski, K.
Miklaszewski, R.
Szydlowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/147553.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
neutron emission
plasma focus
scaling laws
soft X-ray radiation
Opis:
The paper reports on actual operational characteristics of the PF-1000 facility and it presents results of the first neutron experiments performed with a new set of large Mather-type electrodes, which were designed for shots up to 1000 kJ. Dynamics of a current-sheath was studied by means of two high-speed streak cameras and a two-frame camera. The last one was used for the side-on observation of the pinch column. The high-speed streak pictures were taken side-on behind slits oriented in the radial or axial direction. On the basis of the pictures taken behind the radial slit, average values of the radial compression and expansion velocities were estimated. Time-resolved X-ray signals were measured with PIN diodes covered by different filters, and they were compared with other traces (voltage waveforms, dI/dt signals, and neutron-induced pulses) in order to determine their correlation. The total neutron yield (Ytot), i.e. the number of neutrons produced during a single discharge and emitted in various directions, was measured by means of several silver-activation detectors placed at different angles around the PF-1000 experimental chamber.
Źródło:
Nukleonika; 2001, 46, 1; 35-39
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Refined design of a new driver for fast capillary discharge
Autorzy:
Koláček, K.
Boháček, V.
Šunka, P.
Řípa, M.
Kravárik, J.
Powiązania:
https://bibliotekanauki.pl/articles/148339.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
fast capillary discharge
soft X-ray laser
Opis:
A new driver of the fast capillary discharge has been designed. It consists of the Marx generator and radial Blumline pulse forming line. Such a geometry enables axial access to both capillary ends (”transparent capillary”). This arrangement substantially simplifies the experiments (adjustment, monitoring, applications). The designed apparatus is capable of reaching the discharge current of the order of 120 kA and the discharge current rise time 2.9×1012 A/s, which is sufficient for the investigation of amplification in non-traditional electronic transitions.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 45-47
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Refined design of a new driver for fast capillary discharge
Autorzy:
Kolácek, K.
Bohacek, V.
Schmidt, J.
Sunka, P.
Ripa, M.
Kravárik, J.
Powiązania:
https://bibliotekanauki.pl/articles/147571.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
fast capillary discharge
soft X-ray laser
Opis:
A new driver of the fast capillary discharge has been designed. It consists of the Marx generator and radial Blumline pulse forming line. Such a geometry enables axial access to both capillary ends ("transparent capillary"). This arrangement substantially simplifies the experiments (adjustment, monitoring, applications). The designed apparatus is capable of reaching the discharge current of the order of 120 kA and the discharge current rise time 2.9×1012 A/s, which is sufficient for the investigation of amplification in non-traditional electronic transitions.
Źródło:
Nukleonika; 2001, 46, 3; 117-120
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-12 z 12

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies