Economic justification for the new approach of using videobased smoke detection with the aim of decreasing total costs incurred by the untimely detection of fires on ships
Autorzy:
Bistrović, M.
Ristov, P.
Powiązania:
https://bibliotekanauki.pl/articles/135234.pdf
Data publikacji:
2017
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
fire alarm
video technology
computer vision
video detection
smoke detectors
ships
Opis:
Although various methods of using new techniques and technologies in ship fire alarm systems have been developed to date, some of which have made significant improvements in the functioning of such systems, in practice there is still plenty of room for further research regarding the operational efficiency of ship fire alarm systems and its impact on crew, passenger and overall ship safety. The application of electronic and computer technologies enables the development of intelligent solutions to improve the efficiency of ship fire alarm systems. Besides the economic justification, this paper presents a comparative analysis of classical and modern approaches based on video detection and computer vision in the detection of early phase smoke as a precursor to fire incidents. The economic justification of the new approach is concerned with decreasing the costs incurred by the untimely detection of the early stages of fire in ship engine rooms.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2017, 51 (123); 21-27
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Role of Smoke Detectors and Carbon Monoxide Detectors in the Fire Safety of Residential Buildings
Rola czujek dymu i czujek tlenku węgla w bezpieczeństwie pożarowym obiektów mieszkalnych
Autorzy:
Garlińska, Urszula
Iwańska, Marta
Śliwiński, Robert
Florek, Paweł
Powiązania:
https://bibliotekanauki.pl/articles/2060756.pdf
Data publikacji:
2021
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
Integrated Qualifications System
smoke
alarm
detector
electrical apparatus
detection
carbon monoxide
residential buildings
Zintegrowany System Kwalifikacji
ZSK
czujka
dym
tlenek węgla
czad
obiekt mieszkalny
Opis:
Purpose: The aim of this publication is to present the most important aspects of using smoke and carbon monoxide detectors intended for households or similar residential facilities as well as to indicate the advantages and disadvantages of the adopted system solutions that affect the number of detectors installed in this kind of buildings. The article aims to present the issues related to the Integrated Qualifications System (ZSK), i.e. newly developed market qualification, dedicated to installers and maintenance technicians of smoke and carbon monoxide detectors. Introduction: Smoke and carbon monoxide detectors for early detection of existing threats such as fires or escaping carbon monoxide are an important element of fire protection, dedicated primarily to owners of residential buildings. In many countries in the EU it is obligatory to install detectors in homes, whereas at the moment in Poland the only aspect regulated legally is the obligation of the manufacturer of these products to obtain a certificate. Since 2016, the ZSK has been operating in Poland, in which in 2019 the qualifications of installers/maintenance technicians of smoke and carbon monoxide detectors were distinguished. As a result, a person with a market qualification certificate is prepared for independent installation and maintenance of fire safety monitoring devices Methodology: As part of the research process, theoretical research was used, such as: analysis of literature and legal documents, synthesis, generalization, inference, comparison and analogy. As part of the research, documents from such countries as Poland, Great Britain (mainly England), Germany and France were analysed. The selection of individual countries was guided by the level of development of these systems in a given country and the availability of source documents Conclusions: The presented analysis of the requirements for the installation of the smoke and carbon monoxide detectors shows how different the approach is regarding the use of this type of devices. Depending on experiences and the administrative structure of a given country, a variety of regulations, whether legal or normative, can be discerned in the use of smoke and carbon monoxide detectors. ZSK is a well-described system of formal organization and classification of competences and offers the public services at the highest possible quality level. It is also a partial solution to the problem of installing detectors. However, it is necessary to regulate this issue from the legal level, as it was the case in other EU countries, where the installation of detectors in homes is obligatory. Such action will contribute to reducing the victims of fires or inhalation of toxic gases (carbon monoxide).
Cel: Celem niniejszej publikacji jest przedstawienie najważniejszych aspektów stosowania czujek dymu i czujek tlenku węgla w prywatnych obiektach mieszkalnych, a także wskazanie zalet oraz wad przyjętych rozwiązań systemowych, które mają wpływ na liczbę detektorów montowanych w tego typu obiektach. Artykuł przedstawia również zagadnienia związane z Zintegrowanym Systemem Kwalifikacji (ZSK), tj. opracowanej kwalifikacji rynkowej, dedykowanej monterom i konserwatorom czujek dymu i czujek tlenku węgla. Wprowadzenie: Czujki dymu i czujki tlenku węgla to ważny element zabezpieczeń obiektów mieszkalnych. Dedykowane są one wszystkim właścicielom tych obiektów. W wielu krajach UE obligatoryjne jest montowanie czujek w domach, natomiast obecnie w Polsce wymagane jest jedynie ich certyfikowanie przez producenta. Od 2016 roku w Polsce funkcjonuje ZSK, w którym w roku 2019 wyodrębniono kwalifikacje dla monterów/konserwatorów czujek dymu i czujek tlenku węgla. Dzięki temu osoba posiadająca certyfikat kwalifikacji rynkowej jest przygotowana do samodzielnego montażu i konserwacji urządzeń monitorujących bezpieczeństwo pożarowe. Metodologia: W ramach procesu badawczego wykorzystano badania teoretyczne, takie jak: analiza literatury i dokumentów prawnych, synteza, uogólnianie, wnioskowanie, porównanie oraz analogia. Podczas badań dokonano analizy dokumentów z Polski, Wielkiej Brytanii (głównie Anglii), Niemiec i Francji. Przy ich doborze kierowano się poziomem rozwoju tych systemów w danym kraju oraz dostępnością dokumentów źródłowych. Wnioski: Przedstawiona analiza wymagań w zakresie obowiązku instalacji czujek dymu i czujek tlenku węgla pokazuje, jak różne jest podejście do ich stosowania w Polsce i w wybranych państwach europejskich. W zależności od doświadczeń oraz struktury administracyjnej danego kraju można dostrzec różnorodność przepisów prawnych czy normatywnych. ZSK jest opisanym systemem formalnego uporządkowania i klasyfikacji kompetencji i oferuje społeczeństwu usługi na możliwie najwyższym poziomie jakościowym. Niezbędne jest prawne uregulowanie tej kwestii, tak jak zostało to zrobione w innych krajach UE, gdzie instalacja czujek w domach jest obowiązkowa. Takie działanie przyczyni się do zredukowania ofiar pożarów lub zaczadzeń.
Źródło:
Safety and Fire Technology; 2021, 57, 1; 114--133
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detekcja dymu w wielkokubaturowych obiektach infrastruktury transportowe
Fire detection in large-volume transport infrastructure objects
Autorzy:
Klimczak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/312005.pdf
Data publikacji:
2019
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
czujka pożarowa
czujki liniowe dymu
czujki zasysające
wideo detekcja pożaru
detekcja dymu
system sygnalizacji pożarowej
fire detector
smoke line detector
aspiration smoke detector
video fire detection
smoke detection
fire alarm system
Opis:
W artykule omówiono urządzenia (podzespoły wchodzące w skład systemu sygnalizacji pożarowej) służące do detekcji dymu, które można zastosować w celu zapewnienia bezpieczeństwa pożarowego wielkokubaturowych obiektów transportowych. W artykule omówiono zarówno powszechnie stosowane punktowe czujki dymu, czujki liniowe dymu, jak również bardziej zaawansowane technologicznie aspiracyjne czujki dymu (czujki zasysające) oraz czujki wykorzystujące nowoczesne technologie związane z wideo detekcją. Omówiono ponadto praktyczne możliwości w zastosowaniu konkretnych rozwiązań oraz ograniczenia w ich stosowaniu. Zaznaczono kierunki rozwoju systemów sygnalizacji pożarowej, w tym w zakresie detekcji dymu.
The article discusses the possible types of smoke detection devices that can be used to provide fire safety for large volume transport facilities. The article discusses both commonly used point smoke detectors or line detectors, as well as more technologically advanced aspiration smoke detectors (aspiration detectors) and detectors using video detection. Practical possibilities in the application of specific solutions and limitations in their application were also discussed. Development directions of fire alarm systems producers, including smoke detection, have been marked.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2019, 20, 12; 50-54
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rodzaju drewna na czas działania liniowych czujek dymu
The Influence of Wood Type on the Response Time of Optical Beam Smoke Detectors
Autorzy:
Porowski, R.
Janik, N.
Wdowiak, T.
Wnęk, W.
Powiązania:
https://bibliotekanauki.pl/articles/373335.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
czujki liniowe dymu
spalanie drewna
detekcja pożaru
optical beam smoke detectors
wood combustion
fire detection
Opis:
Cel: Celem artykułu jest przeprowadzenie badań doświadczalnych dla dwóch wybranych liniowych czujek dymu, czujki OSID oraz DOP 6001 w zakresie czasów zadziałania w zależności od rodzaju spalanego drewna oraz spalania bezpłomieniowego i płomieniowego. Wprowadzenie: Na przestrzeni lat opracowano wiele typów czujek pożarowych różniących się zasadą działania. Najprostsze z nich to nieskomplikowane czujniki temperatury, najpierw mechaniczne, później, wraz z rozwojem techniki elektroniczne. Zdawano sobie sprawę, że nie wykrywają one zagrożenia dostatecznie szybko, dlatego też poszukiwano rozwiązań, które reagowałyby na pierwsze oznaki rozwijającego się pożaru. Punktowe czujki dymu są łatwe w montażu i obsłudze, gdyż są kompletnym, samowystarczalnym urządzeniem. Ich skuteczność maleje wraz z oddalaniem się źródła dymu od miejsca montażu czujki. W niektórych budynkach, jak np. duże hale magazynowe czy fabryki, dla zachowania odpowiedniego stopnia ochrony należałoby instalować setki czujek punktowych, aby ich zasięg skutecznego działania pokrył całą powierzchnię pomieszczenia. W takiej sytuacji lepszym rozwiązaniem są optyczne liniowe czujki dymu, które w zależności od gęstości ich instalacji, mogą pod względem powierzchni dozorowej zastąpić nawet 20 czujek punktowych. Metodologia: Artykuł został opracowany na podstawie przeprowadzonych badań doświadczalnych w komorze badawczej, przy wykorzystaniu różnych źródeł spalania bezpłomieniowego i płomieniowego. Wnioski: W próbach ze spalaniem bezpłomieniowym dym zaczynał się wydzielać niezwłocznie po umieszczeniu drewna na płycie grzewczej, proces tlenia się drewna był jednostajny. Przebieg parametrów pracy czujek w czasie jest w dużym przybliżeniu liniowy, co oznacza jednostajne tempo zmniejszania się przezroczystości powietrza w komorze badawczej. Spalanie płomieniowe rozpoczyna się od małego płomienia podpalonego alkoholu, który musi zainicjować spalanie drewna. Szybkość spalania, a co za tym idzie ilość wydzielanego dymu, cały czas rośnie, co powoduje zbliżony do wykładniczego przebieg parametrów pracy czujek w czasie. Tłumienie wiązek światła wysyłanych przez nadajnik czujki OSID, przebiega różnie, w zależności od typu spalania. Dym pochodzący ze spalania bezpłomieniowego początkowo tłumi obie wiązki jednakowo, dopiero po czasie pojawia się różnica pomiędzy tłumieniem UV a IR. Podczas spalania płomieniowego różnica jest widoczna natychmiast i wyraźnie powiększa się wraz z rozwojem pożaru testowego.
Aim: The aim of this paper is to carry out an experimental test of the influence of wooden materials on the activation time of two types of optical beam smoke detectors – the OSID and the DOP 6001 – during flaming and non-flaming combustion. Introduction: Over the years, there have been many types of fire detector that differ in the way they operate. A few years ago, it was discovered that many detector types depended on the operation principle. The simplest detectors were temperature detectors, at first mechanical, and then, with the development of technology, also electronic. It was obvious that they did not detect the threat fast enough, so it was essential to find solutions that would respond to the first signs of a developing fire. Spot-type smoke detectors are easy to install and use because they are a complete, self-contained devices. Their effectiveness decreases as the distance between the source of combustion and the location of smoke detectors grows. In some buildings, e.g. large warehouses or industrial plants, for a better fire-safety level, there is a need to install dozens of spot-type smoke detectors to protect large areas. In such cases optical beam smoke detectors could be the best practical solution. Methodology: The article is based on a series of experimental tests in a test chamber with various sources of flaming and non-flaming combustion. Two different types of optical beam smoke detectors were used to test the influence of wooden beams on activation times. Conclusions: During the experiments with non-flaming combustion, intense smoke production started immediately after the initiation of the combustion process. The non-flaming phenomenon was a very stable process for all kinds of tested wood. The activation-time results of optical beam smoke detectors and the evolution of the operational parameters, which was almost linear, indicate that these types of detectors are more effective for non-flaming combustion, as opposed to flaming combustion. Flaming combustion starts with a small flame of burning alcohol, which can initiate the combustion of wood. The burning rate and the intensity of smoke production increased, causing a linear evolution of operation parameters from tested smoke detectors over time. The suppression of light beams emitted by the transmitter of the OSID detectors shows different evolution depending on the type of combustion. Smoke production from non-flaming combustion initially suppresses both light beams. After some delay, the effect of the differences between UV and IR suppression is observed. During flaming combustion, the difference is immediately apparent and clearly increases with the development of the test fire.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 44, 4; 67-82
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie charakterystyk rozproszeniowych aerozoli z zastosowaniem optoelektronicznego czujnika dymu
Investigations of scattering characteristics of aerosols using optoelectronic smoke detector
Autorzy:
Szopa, M.
Mierczyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/209600.pdf
Data publikacji:
2007
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
rozpraszanie promieniowania
optoelektroniczny czujnik dymu
detekcja wielospektralna
scattering of radiation
optoelectronic smoke detector
multispectral detection
Opis:
W artykule przeprowadzono analizę teoretyczną charakterystyk rozproszeniowych aerozoli z zastosowaniem optoelektronicznego czujnika dymu z detekcją wielospektralną. Dzięki zastosowaniu trzech długości fal oraz trzech detektorów umieszczonych pod różnymi kątami względem padającego promieniowania, możliwa jest dziewięciokanałowa analiza rozpraszania promieniowania. taka budowa czujnika umożliwia detekowanie cząstek dymu o rozmiarach z szerokiego zakresu 0.1÷10 μm, co pozwala na wykrywanie dymów czarnych, białych oraz tzw. niewidocznych.
The article presents theoretical analyses of aerosols scattering profile of optoelectronic multichanel smoke detector. Application of tree wavelengths and tree detectors, which were placed at various angles to direction of incident radiation, enables us nine-channel analyses of light scattering. Due to this construction of a sensor, the detection of smoke particles of the sizes from wide range of 0.1-10 μm is possible (detection of black smoke, white smoke and invisible one).
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2007, 56, 3; 167-180
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ prędkości przepływu powietrza na czas zadziałania czujek zasysających dymu
Impact of Air Flow Velocity on Response Time of Smoke Detectors
Autorzy:
Wnęk, W.
Dubicki, J.
Mostowik, N.
Powiązania:
https://bibliotekanauki.pl/articles/136629.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
system sygnalizacji pożarowej
czujki działające z wykorzystaniem światła rozproszonego
czujki działające z wykorzystaniem światła przechodzącego lub jonizacji
czujki zasysające
cząstki dymu
fire detection and fire alarm system
detectors using scattered light
detectors using transmitted light or ionization
aspirating smoke detectors
smoke particles
Opis:
W artykule podjęto się analizy wpływu przepływu powietrza na czas zadziałania czujek zasysających dymu. Omówiono stanowisko pomiarowe wykonane na podstawie norm do badania czujek pożarowych dymu. Zbadano wpływ prędkości przepływu mieszaniny powietrzno-dymowej na rozkład cząstek dymu. Dokonano porównania wpływu prędkości przepływu na czas zadziałania czujek jonizacyjnych, optycznych rozpraszających do czujek zasysających. Badania wykonano dla spalania płomieniowego i bezpłomieniowego. Sformułowano wnioski mające wpływ na proces projektowania systemów zabezpieczeń.
The paper contains an analysis of impact of air flow velocity on response time of aspirating smoke detectors. A measurement appliance, constructed on the basis of standards for fire smoke sensors testing, has been described. The impact of flow velocity of air and smoke mixture on the smoke particles distribution was tested. A comparison of impact of flow velocity on the response time of dispersion optical, ionization detectors and aspirating smoke detectors was performed. The research was performed for flame and flameless combustion. The conclusions , having impact on the protection systems design, were formulated.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2016, 3, 59; 5-19
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ pyłów pochodzenia drzewnego na działanie czujek pożarowych dymu
Influence of Wooden-Based Dusts on Smoke Fire Detectors
Autorzy:
Wnęk, W.
Jargieło, M.
Porowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/373369.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
systemy sygnalizacji pożarowej
czujki dymu
fałszywe alarmy
pył drzewny
fire detection systems
smoke detectors
false alarms
wooden dust
Opis:
Cel: Obecnie poszukuje się rozwiązań w zakresie czujek pożarowych dymu, które nie będą wrażliwe na sygnały zwodnicze powodujące fałszywe alarmy pożarowe central sygnalizacji pożarowej. Jednym z takich sygnałów jest występujący w pomieszczeniach pył drzewny traktowany przez czujkę jako dym o dużych cząstkach. W artykule opisano wykonane badania wybranych czujek dymu dla różnych pyłów drzewnych. Celem podstawowym artykułu jest wybór najbardziej odpornej czujki dymu na cząstki pyłu, bez pogorszenia jej właściwości detekcyjnych. Wprowadzenie: Podczas projektowania instalacji systemów sygnalizacji pożarowej napotyka się na problemy doboru czujek pożarowych pracujących w otoczeniu różnych zakłóceń powodujących fałszywe alarmy. Początkowo zbadano wpływ pyłu celulozowego wytwarzanego przy produkcji czasopism w jednej z drukarni. Następnie przeanalizowano również wpływ innych pyłów. Przy pomiarach mieszaniny cząstek o różnych wielkościach nie można jednoznacznie ocenić ich wpływu na sposób wykrywania. W związku z tym dokonano podziału pyłu ze względu na wielkość jego cząstek na pył o średnicach 100 μm, 200 μm i 500 μm. Pozwoliło to na zbadanie wpływu nie tylko rodzaju drewna, ale także wielkości cząstek pyłu na zadziałanie czujek. Metodologia: W trakcie badań opracowano metodę pomiaru wpływu pyłu na zadziałanie czujek. Dobrano ciśnienie sprężonego powietrza na poziomie 1,5 bar wraz z czasem otwarcia zaworu butli ze sprężonym powietrzem tak, aby osiągnąć najlepsze rozprowadzenie pyłu w pomieszczeniu badawczym. Za krótki czas otwarcia zaworu powodował pozostawanie pyłu w pojemniku, za długi powodował natomiast rozdmuchiwanie obłoku pyłu. W kilku próbach jako optymalny czas przyjęto 3 s. Czujki umieszczono umieszczono pryzmatycznie na przeciwległych ściankach pod sufitem komory w układzie nadajnik-odbiornik, nadajnik-lusterko. Wyniki pomiarów były rejestrowane za pomocą układu komputerowego. Wnioski: W wyniku przeprowadzonych badań, z uwzględnieniem zachowania czujek pożarowych dymu, określono rozwiązanie konstrukcyjne w postaci czujki systemu OSID jako czujki, która najlepiej poradziła sobie z pyłem występującym w zabezpieczanych pomieszczeniach. Jest to spowodowane sposobem obróbki sygnału w czujce. Na zadziałanie miały wpływ wielkość pyłów oraz, w mniejszym stopniu, rodzaj pyłu w odniesieniu do gatunku badanego drewna.
Aim: There is a need of fire detection solutions which are sensitive to deceptive signals. They can lead to false fire alarms. One of such signals is the activation of detectors in case of wooden dusts accumulated in the protected area which is regarded by the detector as smoke with large particles. This paper describes selected experimental results on various detectors and different wooden dusts. The aim of this project is to select a detector that is highly resistant to dust particles. Introduction: During designing fire detection systems there is always a problem in a proper selection of fire detectors operating in environments where there are various sources of false alarms. Initially, the influence of cellulose dusts as could be observed during the production of newspapers at the printing house was studied. Then the influence of other dusts was analyzed. During the measurement of smoke particles of different sizes the influence of particles on the detection cannot be explicitly determined. Due to this fact, tested dust was divided taking into consideration the size of the particles where the diameter was 100 μm, 200 μm and 500 μm. It made it possible to test the influence on the operation of the detectors of not only wooden-based materials but also of the size of dust particles. Methodology: During the tests the methodology of measuring the influence of dust on the activation time of detectors was prepared. The pressure of the compressed air was set at 1,5 bars together with the opening time of the valve of the compressed air container in order for the dust to be emitted evenly in the test chamber. If the valve opening time was too short, the dust remained in the container. If it was too long – the dust was blown all over the chamber. The optimum time was set as 3 s. Tested detectors were located by the ceiling of the chamber in the following manner: transmitter-receiver, transmitter-prismatic mirror on opposite walls. Measurement results were registered using a computer system. Conclusions: As a result of the conducted tests, which included the behaviour of fire detectors smoke, the best design solution was determined that best coped with duste present in protected areas. It is OSID smoke detection system. It is a result of how the signal was processed by the detector. The size of dust particles and, to a smaller degree, type of dust with respect to the tested species of wood influenced the operation of the smoke detector.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 42, 2; 43-55
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies