Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "slab" wg kryterium: Temat


Tytuł:
Realibility of the large size post-tensioned slab-on-grade
Niezawodność wielkogabarytowego kablobetonu jako płyt fundamentowych
Autorzy:
Tur, Andrei V.
Tur, Viktar V.
Powiązania:
https://bibliotekanauki.pl/articles/111033.pdf
Data publikacji:
2019
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
post-tensioned slab
punching shear
slab-on-grade
kablobeton
płyty fundamentowe
Opis:
The present article describes some of the possible ways of usage of the post-tensioned flat slabs and the rational design procedures to provide their structural reliability. Theoretical background of the punching resistance checking, in the case when the piles support the foundation pos-tensioned slabs, presented.For ground floor slabs, an iterative method given for determining design compression pre-stresses distribution in slab sections, taking into account the restrained effect created by the friction shear stresses in contact between slab and the base. In addition, the article presents some uncial practical implementations of the post-tensioned slabs as an artificial base in the presence of weak soils and as a large-size ground floor (slab-on-grade) without any joints.
W artykule opisano niektóre z możliwych sposobów wykorzystania płyt kablobetonowych oraz racjonalne procedury projektowe zapewniające ich niezawodność konstrukcyjną. Przedstawiono tło teoretyczne sprawdzenia wytrzymałości na przebicie w przypadku, gdy pale podtrzymują płyty fundamentowe są wstępnie naprężone. W przypadku płyt fundamentowych podano iteracyjną metodę wyznaczania obliczeniowego rozkładu naprężeń ściskających w przekrojach płyt, uwzględniającą efekt utwierdzenia wywołany naprężeniami ścinającymi w kontakcie płyty z podstawą. Ponadto, w artykule przedstawiono kilka praktycznych zastosowań płyt naprężonych jako sztucznego podłoża na gruntach słabych oraz jako wielkogabarytowe podłoże gruntowe (slab-on-grade) bez żadnych spoin.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2019, 3
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polski rynek rozwiązań stropowych – najpopularniejsze systemy, cz.2
Popularity and criteria for the selection of floor systems in Poland, part 2
Autorzy:
Kisiołek, A.
Powiązania:
https://bibliotekanauki.pl/articles/160344.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
system stropowy
popularność
strop gęstożebrowy
Teriva 4 0/1
płyta prefabrykowana
płyta kanałowa
płyta żelbetowa
płyta sprężona
Filigran
wybór systemu
floor system
popularity
rib-and-slab floor
prefabricated slab
hollow core slab
reinforced concrete slab
prestressed slab
system selection
Opis:
W tej części publikacji podjęty został temat niezgodności z eurokodem powszechnie stosowanych stropów Teriva 4,0/1, a następnie zaprezentowane zostaną stropy z kanałowych płyt prefabrykowanych (żelbetowych i strunobetonowych) z uwzględnieniem lekkiego stropu panelowego Smart oraz zespolony strop typu Filigran.
This part of the publication presents the aspect of non-compliance with the Eurocode of common Teriva flooring types (4.0 /1), followed by the hollowcore concrete slabs (reinforced and prestressed concrete elements) including Smart lightweight floors and Filigran-type composite slab systems.
Źródło:
Przegląd Budowlany; 2018, 89, 1; 22-26
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of multi-ribbed one-way composite slabs made of steel fibre, foam, and normal concrete
Badanie doświadczalne wielorowkowej, jednokierunkowej płyty zespolonej wykonanej z włókna stalowego, pianki i zwykłego betonu
Autorzy:
Wang, Y.
Liu, H. T.
Dou, G. F.
Xi, C. H.
Qian, L.
Powiązania:
https://bibliotekanauki.pl/articles/230929.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
włókno stalowe
beton piankowy
płyta wielorowkowa
płyta jednokierunkowa
płyta zespolona
steel fibre
foam concrete
multi-ribbed slab
one-way slab
composite slab
Opis:
This paper aims to study the effect of reinforcement configuration (steel fibre and rebar) on the mechanical performance of composite slabs of the same total steel contents. We manufactured four pieces of full-scale multi-ribbed composite prefabricated slabs with different reinforcement configurations by using steel fibre-reinforced concrete, foam concrete, and normal concrete. The multi-ribbed composite prefabricated slab has many excellent properties, such as light weight, good thermal and sound insulation. Thus, it can be applied to fabricated structures. In addition, the composite prefabricated slabs with the same total steel contents but with different reinforcement configurations were studied under the same static load, and many technical indicators such as crack resistance capacity, yield load, ultimate load capacity, maximum deflection, destructive pattern, and stress of steel rebar were obtained. Results indicate reinforcement configuration has a significant effect on the mechanical performance of composite prefabricated slabs with the same total steel contents, and composite prefabricated slabs reinforced with longitudinal rebar and steel fibre (volume fraction is 1.5%) have the best mechanical performance and ductility.
Dodanie włókna do betonu może zwiększyć odporność na pękanie, wytrzymałość na rozciąganie i sztywność. A zatem, beton zbrojony włóknem szklanym posiada wiele zastosowań inżynieryjnych jako rodzaj materiałów budowlanych, a ponadto istnieje wiele kodeksów zawierających wskazówki dotyczące jego konstrukcji. Beton zbrojony włóknem stalowym, otrzymywany poprzez dodanie losowo rozproszonego krótkiego włókna stalowego do betonu, jest rodzajem wieloskładnikowego materiału kompozytowego na bazie cementu. Ma dobre właściwości fizyczne i mechaniczne. Beton piankowy, który posiada wiele doskonałych właściwości, w tym lekkość i dobrą izolację termiczną, jest szeroko stosowany jako materiał ścienny, dachowy i podłogowy. Jednakże, ze względu na fakt, iż beton piankowy charakteryzuje się wysoką zdolnością pochłaniania wody, posiada słabą odporność na mrozy po wchłonięciu wody i może łatwo ulegać pęknięciu podczas cykli zamrażania i rozmrażania, co wpływa na funkcję i wygląd zewnętrzny budynku. Natomiast beton zbrojony włóknem stalowym charakteryzuje się dobrą odpornością na pękanie i nieprzepuszczalności. Dlatego też, łącząc zalety betonu zbrojonego włóknem stalowym (dobra nieprzepuszczalność) z wielorowkową strukturą (dobre właściwości mechaniczne), zaprojektowaliśmy nowy rodzaj wielorowkowej, prefabrykowanej płyty zespolonej. Celem niniejszej pracy jest zbadanie wpływu konfiguracji zbrojenia (włókna stalowego i pręta zbrojeniowego) na właściwości mechaniczne płyt zespolonych o takiej samej zawartości stali. Wyprodukowaliśmy cztery kawałki pełnowymiarowych, wielorowkowych, prefabrykowanych płyt zespolonych o różnych konfiguracjach zbrojenia, z wykorzystaniem betonu zbrojonego włóknem stalowym, betonu piankowego i zwykłego betonu. Wielorowkowa, zespolona, prefabrykowana płyta posiada wiele doskonałych właściwości, takich jak lekkość, dobra izolacja termiczna i akustyczna, itp. W związku z tym, może być ona stosowana na wytworzonej konstrukcji. Ponadto, zbadano zespolone, prefabrykowane płyty o takiej samej zawartości stali, lecz różnych konfiguracjach zbrojenia, pod takim samym obciążeniem statycznym i uzyskano wiele wskaźników technicznych, takich jak odporność na pękanie, obciążenie plastyczne, maksymalna nośność, maksymalne ugięcie, destrukcyjny wzór oraz naprężenie stalowych prętów zbrojeniowych. Wyniki pokazują, że konfiguracja zbrojenia ma znaczący wpływ na właściwości mechaniczne zespolonych, prefabrykowanych płyt o takiej samej zawartości stali, a zespolona, prefabrykowana płyta zbrojona podłużnym prętem zbrojeniowym i włóknem stalowym (ułamek objętościowy wynosi 1,5%) charakteryzuje się najlepszymi parametrami mechanicznymi i plastycznością.
Źródło:
Archives of Civil Engineering; 2018, 64, 2; 79-96
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The “double slab”: features and meaning of a residential building type in Barcelona Modern Movement
Autorzy:
Lucchini, Marco
Urban, Gaspar Jaen Y
Powiązania:
https://bibliotekanauki.pl/articles/369681.pdf
Data publikacji:
2019
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
double slab
housing
Barcelona
Modernity
regionalism
Opis:
The paper is a part of a wider research developed by the authors since 2014 about the relationship between Modern Architecture in Barcelona and Milan between ’40s and ’60s . Here a particular building type the „double slab” has been investigated. It is based on a modular design system for housing quite popular among architects in Barcelona and throughout Spain. The “double slab” is very well typologically defined and for this reason got a strong identity but at the same time it is quite flexible and easy to be adapted to different styles which span from pre-modernism to the contemporary styles passing through the Regionalism.
Źródło:
Przestrzeń i Forma; 2019, 40; 107-120
1895-3247
2391-7725
Pojawia się w:
Przestrzeń i Forma
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Creating the optical bistable switch in the dielectric slab doped with asymmetric semiconductor quantum wells
Autorzy:
Nasehi, R.
Powiązania:
https://bibliotekanauki.pl/articles/174447.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
optical bistability
optical multistability
dielectric slab
Opis:
We have investigated the optical switching in a dielectric slab with a novel configuration of solid-state medium. This new scheme combines the attractive features of all-optical switching in dielectric medium doped with asymmetric quantum well nanostructure with the ability to convert the optical bistability to multistability (or vice versa) by using the strength of Fano interference and the energy splitting effect. The dependence of optical bistability behavior on the intensity of the strong coupling field and the slab thickness is also given.
Źródło:
Optica Applicata; 2016, 46, 4; 541-551
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smoothed particle hydrodynamics versus finite element method for blast impact
Autorzy:
Jankowiak, T.
Łodygowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/201966.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
FEM
SPH
blast impact
concrete slab
Opis:
The paper considers the failure study of concrete structures loaded by the pressure wave due to detonation of an explosive material. In the paper two numerical methods are used and their efficiency and accuracy are compared. There are the Smoothed Particle Hydrodynamics (SPH) and the Finite Element Method (FEM). The numerical examples take into account the dynamic behaviour of concrete slab or a structure composed of two concrete slabs subjected to the blast impact coming from one side. The influence of reinforcement in the slab (1, 2 or 3 layers) is also presented and compared with a pure concrete one. The influence of mesh density for FEM and the influence of important parameters in SPH like a smoothing length or a particle distance on the quality of the results are discussed in the paper.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 1; 111-121
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie materiałochłonności stropu żelbetowego pełnego i stropu BubbleDeck
The comparison of reinforced concrete slab and BubbleDeck slab
Autorzy:
Ordon-Beska, B.
Powiązania:
https://bibliotekanauki.pl/articles/2065071.pdf
Data publikacji:
2012
Wydawca:
Politechnika Częstochowska
Tematy:
strop żelbetowy pełny
strop typu BubbleDeck
materiałochłonność
izolacyjność termiczna
reinforced concrete slab
BubbleDeck slab
material consumption
thermal insulation
Opis:
W artykule scharakteryzowano dwa rodzaje stropów żelbetowych: płytę pełną i strop typu BubbleDeck. Dokonano porównania pod względem materiałochłonności: zużycia betonu w warstwie konstrukcyjnej oraz styropianu na podstawie obliczeń izolacyjności cieplnej dla wybranego przypadku przegrody. Przedstawiono także propozycję modyfikacji płyty stropu BubbleDeck i jej wpływ na grubość docieplenia.
The paper concerns comparison between material consumption of two floor slabs kinds: plain reinforced concrete slab and BubbleDeck. Types of structures as well as technology of construction are shortly described. In this comparison concrete consumption and consumption of thermal insulation material are also considered.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2012, 1 (9); 77--83
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Płyty peronowe nowej generacji
New generation platform slabs
Autorzy:
Kamiński, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/129277.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
płyta peronowa
płyta betonowa
beton z odkrytym kruszywem
łuszczenie betonu
concrete slab
platform slab
exposed aggregate concrete
scaling
Opis:
The article describes the problem of the lack of durability of the surface of concrete platform slabs with a standard anti-slip texture, and presents a way to solve the problem by changing the requirements and technology of their production. The article presents the modified requirements for new generation concrete platform slabs, the results of tests of new generation slabs and experience gathered from the testing ground, as well as a summary and conclusions.
Artykuł opisuje problematykę braku trwałości powierzchni betonowych płyt peronowych ze standardową fakturą antypoślizgową. Przedstawia sposób rozwiązania problemu poprzez zmianę wymagań i technologii ich produkcji. W artykule przedstawiono zmodyfikowane wymagania dla betonowych płyt peronowych nowej generacji, wyniki badań płyt nowej generacji i doświadczenia zebrane z poligonu badawczego oraz podsumowanie i wnioski.
Źródło:
Builder; 2020, 24, 10; 40-43
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Statyczna praca kanałowych płyt stropowych opartych na dźwigarach podatnych
Statical work of hollow core slabs on flexible support
Autorzy:
Surma, Mateusz
Derkowski, Wit
Powiązania:
https://bibliotekanauki.pl/articles/161390.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta kanałowa
płyta stropowa
praca statyczna
Slim Floor
podpora podatna
hollow core slab
floor slab
static work
flexible support
Opis:
Artykuł koncentruje się na wybranych aspektach statycznej pracy prefabrykowanych sprężonych płyt wielokanałowych wspartych na wspornikach elastycznych, tzw. struktury typu Slim Floor. Pierwsza część przedstawia zarys historyczny pojawienia się i rozwoju różnych rodzajów stalowych, betonowych i stalowo-betonowych belek zespolonych, wykorzystywanych w prefabrykowanych płaskich stropach, dla których wysokość belki jest tylko nieznacznie większa niż nominalna wysokość płyt. Opisano ponadto ogólną procedurę obliczania wytrzymałości na ścinanie płyt wielokanałowych według zaleceń fib. Wytrzymałość na ścinanie płyt wielokanałowych jest znacząco zredukowana przez odkształcenie poprzeczne systemu płyt stropowych w wyniku odchylenia wiotkiej belki.
The paper is focused on selected aspects of static work of prestressed precast hollow core slabs supported on flexible supports, so-called Slim Floor structures. The first part presents a historical review of the emergence and development of various types of steel, concrete and steel-concrete composite beams, used in precast flat floors, for which the height of the beam is only slightly bigger than the nominal height of the slabs. A general procedure for calculating the shear capacity of hollow core slabs according to the fib recommendations is also described. The shear capacity of hollow core slabs is significantly reduced by the transverse deformation of the floor slab system due to the deflection of the slender beam.
Źródło:
Przegląd Budowlany; 2019, 90, 3; 8-13
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preduprezhdenie deformacijj i avarijj monolitnykh zhelezobetonnykh bassejjnov
Prevention of deformations and accidents of monolithic reinforced concrete pools
Autorzy:
Kotljar, N.
Poshhina, N.
Likhograjj, V.
Powiązania:
https://bibliotekanauki.pl/articles/78067.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
swimming pool
construction
slab
concrete mix
deformation
accident
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 6
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research and Development of the Solidification of Slab Ingots from Special Tool Steels
Autorzy:
Tkadlečková, M.
Michalek, K.
Gryc, K.
Socha, L.
Jonšta, P.
Saternus, M.
Pieprzyca, J.
Merder, T.
Powiązania:
https://bibliotekanauki.pl/articles/356096.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tool steel
steelmaking
slab ingot
numerical modelling
porosity
Opis:
The paper describes the research and development of casting and solidification of slab ingots from special tool steels by means of numerical modelling using the finite element method. The pre-processing, processing and post-processing phases of numerical modelling are outlined. Also, problems with determining the thermophysical properties of materials and heat transfer between the individual parts of the casting system are discussed. Based on the type of grade of tool steel, the risk of final porosity is predicted. The results allowed to improve the production technology of slab ingots, and also to verify the ratio, the chamfer and the external/ internal shape of the wall of the new designed slab ingots.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 3; 1453-1458
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laplace transform solution of the problem of time-fractional heat conduction in a two-layered slab
Autorzy:
Kukla, S.
Siedlecka, U.
Powiązania:
https://bibliotekanauki.pl/articles/122281.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
fractional heat conduction
two-layered slab
Laplace transformation
Opis:
In this paper the Laplace transformation for solving the problem of fractional heat conduction in a two-layered slab has been applied. The different orders of Caputo derivative in the time-fractional equation governed the heat transfer in the layers are assumed. The inverse Laplace transform by using a numerical method is determined. The numerical results obtained by using of the eigenfunctions method and by numerically inverting the Laplace transform are compared.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2015, 14, 4; 105-113
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Load capacity of the mixed bench and slab foundation. Numerical simulations and analytical calculation model
Autorzy:
Grodecki, Michał
Powiązania:
https://bibliotekanauki.pl/articles/1845166.pdf
Data publikacji:
2021
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bench foundation
slab foundation
load capacity
numerical modelling
Opis:
The paper presents results of a numerical investigation on load capacity of the mixed bench and slab shallow foundations (often used in the process of the modernization of the old, antique buildings, which are suffering from lack of the load capacity). The main trouble with use of existing analytical approaches is a non-unique foundation level of the bench and slab, they could even be founded on different geotechnical layers. Proposed analytical model based on Brinch Hansen (EC-7) approach could deal with such a problem. Results of 2D and 3D numerical modelling (ultimate load of the foundation) are compared to the obtained by using the proposed approach. Influence of the soil above the foundation level is also investigated. Different width to length ratios of the foundation are analyzed (from "short" to "long" foundations). Usability of the proposed analytical model in engineering practice is proved by numerical simulations; the obtained results are on the safe side with quite acceptable margin of additional safety.
Źródło:
Studia Geotechnica et Mechanica; 2021, 43, 2; 135-141
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solution of infinite slab static problem using the finite strip method by difference equations
Zastosowanie równań różnicowych w rozwiązaniu problemu statyki nieograniczonej tarczy metodą pasm skończonych
Autorzy:
Pawlak, Z.
Rakowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/279420.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
finite element method
finite strips
difference equations
plane slab
Opis:
An analytical approach to the solution of an infinite slab static problem using the finite strip method is presented. The structure simply supported on its opposite edges is treated as a discrete one. A regular mesh of identical finite strips approximates the continuous structure. This regular slab discretization enables one to derive a fundamental solution for the two-dimensional discrete strip structure in an analytical, closed form. Equilibrium conditions are derived from the finite element method formulation. The set of the infinite number of equilibrium conditions is replaced by one equivalent difference equation. The solution to this equation is the fundamental function, i.e. Green's function for considered slab strip.
W pracy zaprezentowano analityczne rozwiązanie problemu statyki nieograniczonej tarczy metodą pasm skończonych. Tarcza swobodnie podparta na przeciwległych krawędziach jest rozwiązywana jako układ dyskretny. Ciągła struktura jest aproksymowana regularną siatką składającą się z identycznych pasm skończonych. Regularny podział pozwala na wyprowadzenie funkcji fundamentalnych dla dwuwymiarowego układu dyskretnego w analitycznej, zamkniętej formie. Warunki równowagi zostały wyprowadzone zgodnie ze sformułowaniem metody elementów skończonych. Układ równań równowagi składający się z nieskończonej liczby równań został zastąpiony jednym, równoważnym równaniem różnicowym. Rozwiązanie tego równania jest funkcją fundamentalną dla rozpatrywanej tarczy.
Źródło:
Journal of Theoretical and Applied Mechanics; 2009, 47, 3; 629-643
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Phase and group velocities of surface waves in left-handed material waveguide structures
Autorzy:
Taya, S. A.
Elwasife, K. Y.
Qadoura, I. M.
Powiązania:
https://bibliotekanauki.pl/articles/173396.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
slab waveguide
phase velocity
group velocity
left-handed materials
Opis:
We assume a three-layer waveguide structure consisting of a dielectric core layer embedded between two left-handed material claddings. The phase and group velocities of surface waves supported by the waveguide structure are investigated. Many interesting features were observed such as normal dispersion behavior in which the effective index increases with the increase in the propagating wave frequency. The phase velocity shows a strong dependence on the wave frequency and decreases with increasing the frequency. It can be enhanced with the increase in the guiding layer thickness. The group velocity peaks at some value of the normalized frequency and then decays.
Źródło:
Optica Applicata; 2017, 47, 2; 307-318
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stan techniczny elementów balkonów w budynkach wielkopłytowych
Technical status of the balcony elements in the ‘great panel’ buildings
Autorzy:
Dębowski, J.
Firek, K.
Powiązania:
https://bibliotekanauki.pl/articles/160402.pdf
Data publikacji:
2015
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek wielkopłytowy
balkon
rozwiązanie techniczne
płyta balkonowa
połączenie płyta balkonowa-płyta stropowa
stan techniczny
analiza przypadku
precast concrete panel building
balcony
technical solution
balcony slab
balcony slab-floor slab joint
technical condition
case study
Opis:
Budownictwo wielkopłytowe, rozwinięte w latach 60. XX wieku, stanowiło w Polsce aż do połowy lat 80, podstawową formę budownictwa mieszkaniowego. Największy jego rozwój przypada na lata 70., kiedy powstawało najwięcej obiektów wznoszonych w systemach uprzemysłowionych w ramach dużych osiedli mieszkaniowych. Jakość wykonania elementów przygotowywanych w zakładach prefabrykacji, a zwłaszcza jakość montażu gotowych prefabrykatów na placu budowy pozostawiała wiele do życzenia.
‘Great panel’ buildings (also known as the ‘Panelak’ buildings), developed back in the 1960’s became the basic form of housing structures until the mid-1980’s in Poland. These buildings were developed to the largest extent back in the 1970’s, when most of the structures were erected in an industrialized way, within the scope of large housing estates. The quality of the elements prepared at pre-fabrication facilities, and particularly the quality of the executed installation works related to the ready-made, pre-fabricated elements at the construction sites, certainly could have been improved.
Źródło:
Przegląd Budowlany; 2015, R. 86, nr 6, 6; 18-22
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inżynierski problem komputerowego modelowania pracy żelbetowej płyty dwuprzęsłowej z uwzględnieniem sprężystej podatności belki
The engineering problem of the computer modelling of the action of a dual-span reinforced concrete slab taking account of the elasticity of the beam
Autorzy:
Kossakowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/163338.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta żelbetowa
płyta dwuprzesłowa
modelowanie pracy
modelowanie komputerowe
podatność sprężysta
reinforced concrete slab
dual-span slab
action modelling
computer modelling
elasticity
Opis:
W artykule przedstawiono wyniki analizy wpływu sprężystej podatności belki na momenty zginające w płycie żelbetowej. Analizie poddano modelowy strop żelbetowy o konstrukcji płytowo-belkowej, w układzie dwuprzęsłowym o stosunku boków płyt równym 2. Stop podparto na obwodzie i pośrednio w połowie rozpiętości na podatnej belce o znacznej sztywności w stosunku do sztywności płyty. Przeanalizowano sposób modelowania belki w układzie płytowo-belkowym, ze szczególnym uwzględnieniem rzeczywistej sztywności belki w stosunku do sztywności płyty wynikającej z usytuowania tych elementów w stosunku do siebie.
This article presents the results of an analysis of the influence of the elasticity of a beam on the bending moments in a reinforced concrete slab. The analysis concerned a model reinforced concrete ceiling constructed of slabs and beams, in a dual-span arrangement, the ratio of the sides of the slabs being equal to 2. The ceiling was supported, at the perimeter and indirectly at the midpoint of the span, on a flexible beam having significant rigidity relative to that of the slab. The way of modelling the beam in a slab-and-beam system was analysed, with particular attention to the actual rigidity of the beam relative to the rigidity of the slab resulting from the mutual relative position of those elements.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 10, 10; 19-24
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Historic Railway Spans Modernization with the Use of Modern Slab Track Surfaces, on the Example of the Wroclaw Główny – Wroclaw Main Railway Station Reconstruction
Autorzy:
Antoniszyn, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/504527.pdf
Data publikacji:
2017
Wydawca:
Międzynarodowa Wyższa Szkoła Logistyki i Transportu
Tematy:
Modernization
slab track
surface railway
railway bridges
monument protection
Opis:
Modernization or revitalization of a railway line involves the necessity of reconstruction or renovation of practically all the engineering objects and constructions on its premises. While, in the case of objects, not protected by the Historic Preservation Maintenance of City-Owned Buildings, the situation is relatively easy, in the case of historical buildings, the scope of possible construction works can be significantly reduced. On the example of the modernization of the Wroclaw Główny railway station track system, the use of modern slab track is presented, whose aim is to obtain the required performance parameters of the engineering structures (old boreholes) located in its area. The non-skid surfaces used are ERS - rails in the cover and block rails of the EBS type. The use of pavement-free pavements allowed the historic bays to be preserved. Their main girders are made of riveted baffles, without interfering with their historical material. The presented solutions can also be used for the modernization of different types of engineering objects and construction, not necessarily recorded in the register or records of historical monuments - for example, in riveted constructions of those of or unique shape, located on lower category railway lines. It gives opportunity to preserve and continue to use old objects, exposing their beauty and technology, currently not used (for example riveting).
Źródło:
Logistics and Transport; 2017, 34, 2; 47-56
1734-2015
Pojawia się w:
Logistics and Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niezamierzony efekt częściowego zamocowania stropów ze sprężonych płyt kanałowych
Autorzy:
Derkowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/162629.pdf
Data publikacji:
2014
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
płyta strunobetonowa
płyta kanałowa
podparcie
zamocowanie
nośność na ścinanie
floor
prestressed concrete slab
hollow core slab
support
fixing
shear load capacity
Źródło:
Przegląd Budowlany; 2014, R. 85, nr 1, 1; 24-27
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nośności wewnętrznych słupów żelbetowych w obszarze połączenia z płytą żelbetową z betonu lekkiego
The experimental investigations of RC internal columns in the connection zone with lightweight concrete slab
Autorzy:
Urban, T.
Gołdyn, M.
Krawczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/390852.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
beton lekki
beton wysokowartościowy
płyta żelbetowa
słup
węzeł płyta-słup
nośność
lightweight concrete
high strength concrete
reinforced concrete slab
column
slab-column connection
Opis:
W artykule przedstawiono problem nośności słupów wykonanych z betonu wysokiej wytrzymałości przedzielonych żelbetową płytą wykonaną z betonu lekkiego. Zaprezentowano wyniki własnych badań eksperymentalnych trzech modeli reprezentujących połączenie słupa wewnętrznego z płaską płytą żelbetową wykonaną z betonu lekkiego o trzykrotnie mniejszej wytrzymałości od betonu słupa. Parametrem zmiennym relacjonowanych była wielkość obciążenia płyty. Wykonane badania wykazały brak wpływu tego parametru na wytrzymałość efektywną betonu słupa.
This paper presents the problem of load carrying capacity of the columns made of high-strength reinforced concrete which are separated by slab made of lightweight concrete. The experimental investigations of three models representing the internal connection between column and flat slab made of lightweight concrete of the strength tree times less than concrete strength of column are presented. The effort degree on the punching shear capacity stands for the variable parameter in the presented study. The performed study shows that there is no effect of this parameter on the effective concrete strength of the column.
Źródło:
Budownictwo i Architektura; 2013, 12, 1; 187-194
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczeniowa ocena nośności płyt żelbetowych w strefie przęsłowej w warunkach działania pożaru
Computational assessment of the load bearing capacity of reinforced concrete slabs under fire conditions
Autorzy:
Maciąg, Michał
Spodzieja, Szymon
Adamczewski, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1845185.pdf
Data publikacji:
2020
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
płyta
żelbet
nośność
pożar
slab
reinforced concrete
load capacity
fire
Opis:
W pracy obliczono nośność pożarową płyt żelbetowych o grubościach nie mniejszych niż 15 cm. Przyjęto standardową krzywą pożarową. Obliczenia wykonano przy pomocy metody Izoterma 500. Wyznaczono krzywe równowagi pomocne do wyznaczenia nośności ogniowej analizowanych płyt. Jako pomoc dla projektantów wyniki zebrano w formie tabelarycznej.
The load capacity of reinforced concrete slabs, with a thickness not less than 15 cm, under fire conditions was calculated in the publication. A standard fire curve was adopted. The calculations were made using the simplified method of Isotherm 500. The equilibrium curves, helpful in determining the fire resistance of the analysed boards, were determined. The results were tabulated to be used by designers.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2020, 25, 3; 181-194
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nonlinear finite element analysis of punching shear strength of reinforced concrete slabs supported on L-shaped columns
Autorzy:
Zhang, Qing
Milligan, Graeme J.
Polak, Maria Anna
Powiązania:
https://bibliotekanauki.pl/articles/390883.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
punching shear
finite element analysis
L-shaped columns
slab openings
Opis:
Most current concrete design codes include provisions for punching shear of reinforced concrete slabs supported on columns with L, T, and cruciform shapes. Reference studies verifying the accuracy of these code provisions are typically not provided. Empirical data of punching failures of slabs supported on columns with L, T, and cruciform shapes are limited due to the cost and time required to test specimens with slab thicknesses and column sizes commonly used in practice. In this paper, the punching shear behaviour of five interior L-shaped slab-column connections, one without a slab opening and four with slab openings, subjected to static concentric loading are analyzed using a plasticity-based nonlinear finite element model (FEM) in ABAQUS. The FEM is similar to models previously calibrated at the University of Waterloo and are calibrated considering nine slabs that are tested to study the impact of column rectangularity on the punching shear behaviour of reinforced concrete slabs. The finite element analysis results indicate that shear stresses primarily concentrate around the ends of the L, and that current code predictions from ACI 318-19 and Eurocode 2 may be unconservative due to the assumed critical perimeters around L-shaped columns.
Źródło:
Budownictwo i Architektura; 2020, 19, 4; 125-138
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strengthening of bi-axially loaded RC slab-column connection using steel plates and stiffeners
Autorzy:
Neamah, Zainab A.
Al-Ramahee, Munaf A.
Powiązania:
https://bibliotekanauki.pl/articles/35520201.pdf
Data publikacji:
2021
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
bi-axial loads
eccentric load
flat slab
strengthening
steel plates
Opis:
This paper presented a strengthening technique for enhancement reinforced concrete (RC) slab-column connection behavior using steel plates and steel stiffeners. A bi-axial load was applied with an eccentricity of 150 mm in both x and z directions. Four specimens with dimensions of 1,600 × 1,600 × 100 mm were tested in this research. The steel plate dimensions were chosen to be 600 × 600 and 800 × 800 mm with 6 mm thickness. The steel stiffeners are used to support and enhance the steel plate that it is extended from column to the slab-column connection with different dimension. The results showed an improvement in the stiffness of slab and increasing in the ultimate capacity. Also, when the steel plates dimensions increased, the ultimate capacity and stiffness increased.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2021, 30, 1; 29-37
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental study of hybrid rubberized composite slabs
Autorzy:
Subashree, P.
Thenmozhi, R.
Powiązania:
https://bibliotekanauki.pl/articles/230153.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
okruchy gumy
płyta gumowana
płyta betonowa
próba udarności
pochłanianie energii
indeks plastyczności
crumb rubber
rubberized slab
concrete slab
impact test
energy absorption
ductility index
Opis:
Rubberized concrete is made up of scrap tyre rubbers where the fine aggregate is partially replaced by it, as the waste rubber is being a threat to the environment. It is estimated that only 4% of the waste tyre is used in the application of civil engineering and also there is shortage of fine aggregates. The primary objective of this study is to investigate the preliminary concrete properties of M25 and M30 concretes. The fine aggregate is replaced by pre-treated crumb rubber with 10, 15 and 20 % of total weight. Various tests are conducted on the rubberized concrete specimens such as compressive strength, split tensile strength, flexural strength and slump test. The investigation is carried out to determine the impact load behavior of hybrid rubberized composite slabs. In addition 0%, 1%, 1.5%, and 2% of replacement of rubber fibers for total weight of coarse aggregate is also made. The specimen of size 300 mm x 300 mm x 50 mm thickness is subjected to drop hammer test to find its performance against the impact loads. The number of blows for the first crack and complete failure of slab was found and the characteristics were studied.
Źródło:
Archives of Civil Engineering; 2018, 64, 4/II; 21-29
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczeniowa ocena nośności płyt żelbetowych w strefie przypodporowej w warunkach działania pożaru
Computational assessmest of the load bearing capacity of reinforced concrete slabs in a support area under fire conditions
Autorzy:
Maciąg, Michał
Spodzieja, Szymon
Adamczewski, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1845187.pdf
Data publikacji:
2020
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
płyta
żelbet
nośność
pożar
slab
reinforced concrete
load capacity
fire
Opis:
W pracy obliczono nośność płyt żelbetowych w warunkach działania pożaru o grubościach nie mniejszych niż 15cm. Przyjęto standardową krzywą pożarową. Obliczenia wykonano uproszczoną metodą Izoterma 500. Wyznaczono krzywe równowagi pomocne do wyznaczenia nośności ogniowej analizowanych płyt. Jako pomoc dla projektantów wyniki zebrano tabelarycznie.
The load capacity of reinforced concrete slabs, with a thickness not less than 15 cm, under fire conditions was calculated in the publication. A standard fire curve was adopted. The calculations were made using the simplified method of Isotherm 500. The equilibrium curves, helpful in determining the fire resistance of the analysed boards, were determined. The results were tabulated to be used by designers.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2020, 25, 3; 137-150
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wzmocnienia konstrukcji mostowej na jej stan graniczny
Analysis to effect of bridged contruction reinforcement for its ultimate state
Autorzy:
Kaminski, R.
Spychalska, K.
Delyavskyy, M.
Powiązania:
https://bibliotekanauki.pl/articles/40898.pdf
Data publikacji:
2009
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
konstrukcja
kratownice przestrzenne
mosty
nosnosc
plyty betonowe
plyty zelbetowe
stany graniczne nosnosci
wzmocnienia
bridge
concrete slab
construction
load capacity
reinforced concrete slab
reinforcement
space truss
Źródło:
Acta Scientiarum Polonorum. Architectura; 2009, 08, 3-4
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Himyarite “knight” and Partho-Sasanian art
Autorzy:
SKUPNIEWICZ, Patryk
Powiązania:
https://bibliotekanauki.pl/articles/517560.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Przyrodniczo-Humanistyczny w Siedlcach
Tematy:
Parthian
Sasanian
Yemen
Arabia
weaponry
arms
armor
stone slab
rock reliefs
Opis:
The Himyarite slab from Zafar contains several distinctive features shared with some Parthian and Sasanian art pieces, but its relation with Naqš-e Rostam friezes proposed by Yule and Robin does not seem convincing. 1. It shows a rider clad in long scale armor analogically to a terracotta tile from the British Museum (fig. 9); 2. There is an infantry attendant with an axe depicted over the mount’s rump similarly to the Tang-e Sarvak frieze, where there are two foot warriors and a battle axe too (fig. 7); The horse position on Tang-e Sarvak is either standing or rearing as on discussed relief. 3. Round shield and raised right hand with a lance as on Ṭāq-e Bostān relief (fig. 12). 4. The layout of the original piece must have therefore been squarish rather than horizontally extended, with the opponent of the main figure marginalized. Therefore Himyarite artisans either followed unknown or not preserved Iranian iconographic pattern or combined the features of different canons. Yule and Robin have pointed out that simple snaffle was depicted in place of elaborate and decorative Sasanian bridle, an element usually pronounced in Sasanian art but not always clearly marked in Parthian iconography, especially in smaller objects. It cannot be however excluded that the slab rather follows a Roman tradition captured in local taste.
Źródło:
Historia i Świat; 2016, 5; 57-75
2299-2464
Pojawia się w:
Historia i Świat
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detale projektowe jako jedna z przyczyn wad pierwotnych żelbetowych stropów w garażu wielostanowiskowym
Design details recognized as the reasons of defects of reinforced concrete floors in the multi-storey garage
Autorzy:
Szerafin, J.
Halicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/390552.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
garaż wielostanowiskowy
płyta stropowa
błędy projektowe
garage
floor slab
design errors
Opis:
„Case study” przedstawia przypadek garażu wielokondygnacyjnego, w którym wkrótce po wykonaniu stwierdzono uszkodzenia płyt stropowych i zastoiska wody. Przyczyną obok niedostatecznej jakości betonu było błędne rozwiązanie spadków płyty stropowej oraz złe rozmieszczenie wpustów odprowadzających wodę.
In the paper a 'case study' of a six-storey garage is described. Soon after the beginning of use the cracking and other damages of reinforced concrete floor slabs as well as stagnant pools of water on them were observed. The poor concrete, improper design solution regarding the slabs inclinations and distribution of pipes removing the rain water were recognized as causes of these damages.
Źródło:
Budownictwo i Architektura; 2016, 15, 2; 13-18
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flexural behaviour of concrete slabs reinforced with FRP bars in experiments and according to ACI 440.1R guide
Autorzy:
Abramski, M.
Korzeniowski, P.
Tisler, W.
Powiązania:
https://bibliotekanauki.pl/articles/297798.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
basalt fibre
carbon fibre
FRP reinforcement
reinforcement bar
concrete slab
experiment
Opis:
The paper presents research conducted on two concrete slabs reinforced with the carbon composite bars and two other concrete slabs reinforced with basalt composite bars. The carbon bars were plain, while the basalt ones were ribbed. The slabs were experimentally investigated in the flexural state of effort with the concentrated forces applied. The results are compared with the analytical solution proposed in the guide ACI 440.1R-06 of the American Concrete Institute. The calculation procedures in respect of flexure, as well as deflection, as per ACI 440.1R-06, are presented, briefly explained and discussed in the paper. Some suggestions to revise the existing procedures are offered. The authors present and discuss the following results of their experimental investigation: the ultimate capacity of the slabs, their modes of failure, deflections and the strains in reinforcement.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2016, 19(4); 339-357
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A solution to the problem of time-fractional heat conduction in a multi-layer slab
Autorzy:
Siedlecka, U.
Kukla, S.
Powiązania:
https://bibliotekanauki.pl/articles/122925.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
heat conduction
fractional derivative
multi-layer slab
przewodnictwo ciepła
pochodna ułamkowa
Opis:
In this paper a solution of the time-fractional heat conduction problem in a multilayer slab is presented. The boundary conditions of the third kind and the perfect contact at the interfaces are assumed. A space-time dependent volumetric heat source in the slab and time dependent surroundings temperatures are taken into account in the formulation of the problem. The solution is obtained in the form of a series expansion with respect to eigenfunctions of an auxiliary problem. A numerical example shows temperature distribution in the slab for various values of the order of the Caputo fractional derivative in the heat conduction equation.
Źródło:
Journal of Applied Mathematics and Computational Mechanics; 2015, 14, 3; 95-102
2299-9965
Pojawia się w:
Journal of Applied Mathematics and Computational Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of hybrid steel-polypropylene fiber on punching shear behavior of flat slab with an opening
Autorzy:
Zaezue, Shahzinan J.
Hadi, Waleed K.
Powiązania:
https://bibliotekanauki.pl/articles/36060590.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
hybrid fiber
steel fiber
polypropylene fibre
punching shear
slab with opening
Opis:
This research aimed to gain a better understanding of how the addition of fiber influences the punching shear capacity of two-way slabs by conducting an experiment into the structural behavior of flat slabs with and without a square opening using different volume fractions of hybrid steel-polypropylene fiber (0%, 0.9%, 1.05% and 1.8%). Ten 700 × 700 × 70 mm slabs were divided into five pairs, with two samples used as control samples (with and without openings), and eight other samples with different volume fraction of fibers. Results showed that an increase in fiber content enhanced the shear strength of the slabs. For example, as the volume fraction of hybrid fiber increased from 0.0 to 1.8%, the ultimate load increased by 52% for slabs without an opening and up to 42% for slabs with an opening.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2023, 32, 1; 3-17
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Płyta wagi samochodowej 30-tonowej z betonu sprężonego cięgnami bez przyczepności
A new 30 T truck weighbridge build out of prestressed concrete with tendons without adhesion
Autorzy:
Szydłowski, R.
Ślaga, Ł.
Łabuzek, B.
Powiązania:
https://bibliotekanauki.pl/articles/161576.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
waga samochodowa
płyta wagi samochodowej
płyta sprężona
cięgno bez przyczepności
badanie
naprężenie-odkształcenie
truck scale
truck scale slab
prestressed concrete slab
unbonded tendon
examination
stress-strain
Opis:
Pierwsze w Polsce pomosty wag samochodowych 60-tonowych z betonu sprężonego cięgnami bez przyczepności opracowano i przebadano w Instytucie Materiałów i Konstrukcji Budowlanych Politechniki Krakowskiej w 2014 r. Obecnie opracowano nową, sprężoną płytę wagi samochodowej o wymiarach 0,24×3,00×8,00 m i nominalnej nośności 30 ton. Analogicznie do poprzedniego rozwiązania płytę zaprojektowano jako element częściowo sprężony cięgnami bez przyczepności, pracujący w stanie zarysowanym. Wykonany prototyp poddano obciążeniu cyklicznie zmiennemu w zakresie 3–24 ton o liczbie cykli wynoszącej 1 008 000. W pracy przedstawiono założenia projektowe, wyniki analizy statyczno-wytrzymałościowej, szczegóły konstrukcyjne oraz program i wyniki badań wraz z wyciągniętymi wnioskami.
The first Polish truck scale slabs with capacity of 60 tonnes made of prestressed concrete with unbonded tendons have designed and tested in Institute of Building Materials and Structures of Cracow University of Technology in 2014. A new prestressed concrete slab of 30 tons capacity and dimensions of 0,24×3,00×8,00 m has already devised. It is a partially prestressed element with unbonded tendons designed as cracked, similar to previous solution. The prototype was constructed and tested under cyclic load with changeable load between 3 and 24 tons, in number of 1 008 000 cycles. The paper presents design assumptions, static and strength analysis results as well as structural details and test program with results. Based on obtained results some conclusions have been drawn.
Źródło:
Przegląd Budowlany; 2017, 88, 6; 33-39
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sprężone płyty kanałowe - błędy produkcyjne, montażowe i eksploatacyjne
Pre-stressed channel slabs - errors in production, building and use
Autorzy:
Ajdukiewicz, A.
Kliszczewicz, A.
Węglorz, M.
Powiązania:
https://bibliotekanauki.pl/articles/163193.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
płyta betonowa
płyta kanałowa sprężona
błąd produkcyjny
błąd montażu
błąd eksploatacji
przykład
floor
concrete slab
pre-stressed channel slab
manufacture fault
assembly fault
operation fault
examples
Opis:
Stropy z kanałowych płyt strunobetonowych należą do najbardziej popularnych prefabrykowanych stropów o rozpiętości powyżej 6,0 m zarówno w budawnictwie ogólnym, jak i przemysłowym. Płyty są produkowane i stosawane masowo w wielu krajach od prawie 50 lat, a w Polsce od wczesnych lat 70. ubiegłego wieku. Udział w produkcji i stosowaniu ma więc już drugie pokolenie i tak długa tradycja oraz zbierane doświadczenia mogłyby wskazywać na ustabilizowane poprawne metady projektowania, produkcji, montażu i eksploatacji. Tymczasem, zdarza się ciągle wiele błędów i usterek wynikających z wprowadzanych wadliwych modyfikacji, nieznajomości specyfiki zasad produkcji lub nieświadomości stopnia wytężenia tych elementów. Przedstawiono i skomentowano typowe przykłady takich błędów.
Cellings made of channel slabs of pre-tensioned pre-stressed concrete are among the most popular prefabricated ceilings, with spans of over 6.0 m, in both general and industrial construction. The slabs have been produced and used in large quantities in many countries for almost 50 years, and in Poland since the early 1970s. They are therefore now being produced and used by a second generation, and it might be expected that this long tradition and the experience acquired would have led to proper and stable methods of design, manufacture, building and use. However many errors and defects still occur, resulting from faulty modifications, ignorance of the specific principles of production or unawareness of the forces to which these elements are subjected. This paper presents and discusses typical examples of such errors.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 2, 2; 34-40
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prawidłowość wykonywania wycięć w strunobetonowych płytach kanałowych oraz konsekwencje błędów w tym zakresie i sposoby naprawynadal
The correctness of making cut-outs in prestressed concrete hollow-core slabs, the consequences of errors and methods of repair
Autorzy:
Błaszczyński, Tomasz Z.
Gwozdowski, Błażej
Sinacki, Dawid
Powiązania:
https://bibliotekanauki.pl/articles/128808.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
awaria
płyta kanałowa
strop strunobetonowy
wycięcie
projektowanie
otwór
płyta z otworem
błąd
naprawa
failure
hollow core slab
prestressed slab
cutout
designing
hole
plate with hole
error
repair
Opis:
Stosowanie prefabrykowanych płyt strunobetonowych stało się tak powszechne, że zajmują się nimi już wszyscy, uważając te elementy za nieskomplikowane. Dotyczy to również wykonawstwa oraz modernizacji już zrealizowanych obiektów budowlanych. Pomimo szczegółowych wytycznych producentów i projektantów tego rodzaju płyt problemem wciąż jest zbyt duża dowolność w ich wycinaniu i wykonywaniu otworów, zwłaszcza na etapie realizacji lub zmian sposobu użytkowania w trakcie istnienia obiektów budowlanych. W pracy przedstawiono ogólne zasady bezpiecznego wycinania i otworowania prefabrykowanych płyt strunobetonowych oraz przypadki błędów popełnionych przy projektowaniu i realizacji stropów płytowych, prowadzące do stanów awaryjnych.
The usage of prefabricated prestressed hollow-core slabs has become so widespread that everyone is already considering these elements as simple. This also concerns the execution and modernization of already realized buildings. Despite the detailed guidelines for designers of this type of slabs, still is a problem with incorrectly make cut-offs and holes, especially at the stage of implementation or changes in the way of use during the existence of buildings. The paper presents general principles for safe cutting and opening of prefabricated prestressed hollow-core slabs and cases of errors made in the design and implementation of slab floors, leading to emergency conditions.
Źródło:
Builder; 2020, 24, 9; 36-40
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Casting and Solidification of Slab Ingot from Tool Steel Using Numerical Modelling
Modelowanie numeryczne odlewania i krzepnięcia wlewków stalowych ze stali narzędziowej
Autorzy:
Tkadlečková, M.
Michalek, K.
Machovčák, P.
Kováč, M.
Socha, L.
Powiązania:
https://bibliotekanauki.pl/articles/356253.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steel
slab ingot
macrosegregation
cracks
modelling
stal
wlewki stalowe
segregacja
pęknięcia
modelowanie
Opis:
The main problem in the production of forgings from tool steels, especially thick plates, blocks, pulleys and rods which are used for special machine components for demanding applications, it is the inhomogeneous structure with segregations, cracks in segregations or complex type of non-metallic inclusions MnS and TiCN. These forgings are actually produced from conventional forging ingots. Due to the size of forgings, it would be interesting the production of these forgings from slab ingots. It is possible that the production of forgings from slab ingots (which are distinguished by a characteristic aspect ratio A/B), it would reduce the occurrence of segregations. The paper presents the verification of the production process of slab steel ingots in particular by means of numerical modelling using finite element method. The paper describes the pre-processing, processing and post-processing phases of numerical modelling. The attention was focused on the prediction of behavior of hot metal during the mold filling, on the verification of the final porosity, of the final segregation and on the prediction of risk of cracks depending on the actual geometry of the mold.
Głównym problemem w produkcji odkuwek ze stali narzędziowych, szczególnie grubych płyt, bloków, kół pasowych i prętów, używanych do specjalnych elementów maszyn dla żądanych zastosowań, jest niejednorodna struktura z segregacją, pęknięciami w segregacji lub złożonego typu niemetaliczne wtrącenia MnS i TiCN. Te odkuwki są rzeczywiście produkowane z konwencjonalnych wlewków przeznaczonych do kucia. Ze względu na wielkość odkuwek, można by produkować te odkuwki z wlewków płaskich. Możliwe, że produkcja odkuwki z wlewków płaskich (które wyróżniają się charakterystycznym stosunkiem A/B), pozwoli zmniejszyć występowanie segregacji. W pracy przedstawiono weryfikację procesu produkcji wlewków płaskich za pomocą modelowania numerycznego z wykorzystaniem metody elementów skończonych. Artykuł opisuje fazy modelowania numerycznego: wstępną fazę przetwarzania, obróbkę i przetwarzanie końcowe. Zwrócono uwagę na zachowanie się ciekłego metalu podczas napełniania wlewnic, na weryfikację końcowej porowatości, końcowej segregacji i przewidywania ryzyka pęknięcia w zależności od rzeczywistej geometrii wlewnic.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2879-2886
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculation of deflection of one-layer and two-layer slabs supported on four sides
Raschet progibov odno- i dvukhslojjnykh plit, opertykh po konturu
Autorzy:
Smorkalov, D.
Powiązania:
https://bibliotekanauki.pl/articles/792189.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
slab
deflection
steel fibre
concrete
construction material
reinforcement
experimental research
calculation model
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2014, 14, 4
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt wybranych elementów konstrukcji budynku mieszkalnego ze stropami przewieszonymi z analizą zastosowania lekkiego betonu kruszywowego jako alternatywy betonu zwykłego
Detailed design of the selected structural elements of the residential building with overhang floor slabs including analysis of the use of LWAC as an alternative to NWC
Autorzy:
Nojek, Damian
Gołdyn, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2142049.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop płaski
płyta transferowa
beton lekki kruszywowy
przebicie płyty
analiza porównawcza
praca magisterska
flat slab
flat floor
transfer slab
lightweight aggregate concrete
punching shear
comparative analysis
master thesis
Opis:
W artykule przedstawiono projekt wielokondygnacyjnego budynku mieszkalnego ze stropami przewieszonymi i płytą transferową. W pracy analizowano zastosowanie lekkiego betonu kruszywowego jako alternatywy betonu zwykłego, z którego wykonano stropy międzykondygnacyjne. Omówione różnice we właściwościach i sposobie projektowania konstrukcji z obu rodzajów betonu. Dokonano porównania wyników obliczeń - m.in. sił wewnętrznych, ugięć, jak również zapotrzebowania na zbrojenie, a także przedstawiono uproszczoną analizę ekonomiczną obu rozwiązań.
The paper presents a design of the multi-storey residential building with overhang ceilings and transfer slab. The study analyses the use of lightweight aggregate concrete as an alternative to ordinary concrete, from which the inter-story ceilings were made. The differences in the properties and design principles of structural elements made of both types of concrete were discussed. The results of the calculations were compared - including i.a. internal forces, deflections and required reinforcement. A simplified economic analysis of both solutions was also presented.
Źródło:
Przegląd Budowlany; 2022, 93, 5-6; 55--62
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conversion of compression test data into flow curve, accounting for barrelling
Autorzy:
Khoddam, Shahin
Hodgson, Peter D.
Powiązania:
https://bibliotekanauki.pl/articles/29520227.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
compression test
flow curve identification
barrelling induced shear
multi-layer
slab analysis
Opis:
Current solutions to convert the axis-symmetric compression test (ACT) data to flow data ignore the barrelling deformation in the sample. This work presents a solution for the test which accounts for the sample’s barrelling by discretising it into a finite number of layers of different radii. The solution assumes a constant and sliding friction at the anvil-sample interface. The sample’s flow behaviour is identified by combining a recent kinematic solution of the test, Prandtl–Reuss–Mises’s equations and a slab-analysis of the layers. It also involves an averaging of the effective plastic stresses developed in the individual layers. The solution is verified for a special case of no-barrelling which matches the currently used solution.
Źródło:
Computer Methods in Materials Science; 2021, 21, 3; 157-162
2720-4081
2720-3948
Pojawia się w:
Computer Methods in Materials Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of flat slab column reinforced concrete frames in low cost housing construction
Autorzy:
Onyshchenko, V.
Pavlikov, A.
Mykytenko, S.
Powiązania:
https://bibliotekanauki.pl/articles/111103.pdf
Data publikacji:
2016
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
flat slab column conduit
reinforced concrete framework of building
low-cost housing
Opis:
In research presents an analysis of flat slab column reinforced concrete frames in low cost housing construction. The features of precast flat slab column conduit within reinforced concrete frame building have been analyzed. The problems in designing flat slab column frame to improve its reliability are under consideration. Suggestions concerning the ways of improving flat slab column frame building calculations are presented. Precast flat slab column frame constructive system is promising for construction of residential and public buildings. In order to reduce the values of bending moments in the joints of columns, it is suggested to apply solid diaphragms with the functions of taking up the vertical loads in order to take up horizontal loads. It seems reasonable to define the required amount of reinforcement bars in plates by means of the kinematic limit equilibrium method.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2016, 3; 29-33
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Medieval Christian Necropolis in the Kopachyntsi hillfort (Ukraine). Unpublished Research Materials
Autorzy:
Lutsyk, Iryna
Powiązania:
https://bibliotekanauki.pl/articles/2085881.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Rzeszowski. Instytut Archeologii Uniwersytetu Rzeszowskiego. Muzeum Okręgowe w Rzeszowie
Tematy:
Sub-Carpathian region
burial
funeral culture
under the slab burial
pilgrimage relics
Opis:
The article deals with unpublished research materials from the medieval Christian cemetery located on the territory of the hillfort in the village of Kopachyntsi in Sub-Carpathian region (Ukraine) which were conducted in 1953. Excavations were verified, objects and artefacts were analysed, and an attempt to attribute and date them was made. The site is represented by inhumations in pits, as well as burials under stone slabs. The so-called “under the slab burials” are a separate category of monuments of funeral culture, which is characterized by its diffusion only on the territory of Halician-Volhynian state, but not the whole of Kyiv Rus’. At the same time, such monuments are known in Slovakia, Czech Republic, Germany, Bulgaria, Romania, Macedonia and Poland. Data on most of the under the slab monuments discovered on the territory of Ukraine are often uninformative, and therefore the publication of the results of stationary archaeological excavations is extremely important for understanding this cultural and religious phenomenon. Special attention is paid to a rare stone cross that was found by the deceased. The search for analogies allows us to conclude that it may be a pilgrimage relic.
Źródło:
Analecta Archaeologica Ressoviensia; 2021, 16; 125-145
2084-4409
Pojawia się w:
Analecta Archaeologica Ressoviensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Cracking in concrete near joints in steel-concrete composite slab
Zarysowanie płyty żelbetowej w strefie przywęzłowej stropu zespolonego
Autorzy:
Niedośpiał, M
Knauff, M.
Barcewicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/396490.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
cracking
steel-concrete composite slab
semi-rigid joints
zarysowanie
strop zespolony
węzły podatne
Opis:
In this paper results of the experimental tests of four full-scale composite steel-concrete elements are reported. In the steel-concrete composite elements, a steel beam was connected with a slab cast on profiled sheeting, by shear studs. The end-plates were (the thickness of 8 mm, 10 mm and 12 mm) thinner than in ordinary design. Joints between the column and the beams have been designed as semi-rigid, i.e. the deformations of end-plates affect the distribution of forces in the adjacent parts of the slab. The paper presents the theory of cracking in reinforced concrete and steel-concrete composite members (according to the codes), view of crack pattern on the surface of the slabs and a comparison of the tests results and the code calculations. It was observed, that some factors influencing on crack widths are not taken in Eurocode 4 (which is based on Eurocode 2 with taking into account the phenomenon called „tension stiffening”).
W artykule przedstawiono wyniki badań czterech elementów zespolonych. Kształtownik stalowy połączony był z betonowym stropem wykonanym na blasze fałdowej. W modelu zastosowano cienkie blachy czołowe (o grubości 8 mm, 10 mm i 12 mm), cieńsze niż zwykle przyjmowane w praktyce projektowej. Połączenie to zaprojektowano jako podatne tzn. takie, w którym odkształcenia blach czołowych mają istotny wpływ na rozkład sił w połączeniu. Przedstawiono normową teorię dotyczącą zarysowania elementów żelbetowych i zespolonych, obraz zarysowania stropu oraz porównano otrzymane wyniki z obliczeniami wykonanymi wg aktualnych norm. Zauważono, iż nie wszystkie czynniki obliczania szerokości rys w konstrukcjach zespolonych są zdefiniowane w normie projektowania konstrukcji zespolonych (która w tej kwestii odwołuje się do normy projektowania konstrukcji żelbetowych z uwzględnieniem zjawiska „tension stiffening”).
Źródło:
Civil and Environmental Engineering Reports; 2015, 16; 167-179
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stropy zespolone z desek strunobetonowych
Composite slab made of precast pre-tensioned concrete planks
Autorzy:
Skupień, Piotr
Derkowski, Wit
Powiązania:
https://bibliotekanauki.pl/articles/129147.pdf
Data publikacji:
2019
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
strop zespolony
deska strunobetonowa
prefabrykacja
precast structure
pre-tensioned concrete plank
composite slab
Opis:
Producenci prefabrykatów betonowych oferują wiele rozwiązań częściowo lub w pełni prefabrykowanych stropów, z których każde lepiej spełnia swoje funkcje w jednych warunkach użytkowania obiektu, a gorzej pracuje w innych zastosowaniach. Zalety, jakie niesie ze sobą prefabrykacja, są coraz częściej dostrzegane przez wszystkich uszestników procesu budowlanego, w tym również przez producentów chcących zaspokoić nacisk ze strony rynku budowlanego na opracowanie nowszych, lepszych i bardziej hybrydowych rozwiązań, tak aby możliwa była konkurencja z technologią tradycyjną wznoszenia obiektów, czyli betonem monolitycznym. Na Politechnice Krakowskiej zaproponowano wykonanie stropu ze strunobetonowych elementów nieznacznej grubości do zastosowania jako szalunku traconego dla zbrojonego nadbetonu [9, 10] wykonanego z betonu lekkiego. Powstały strop zespolony byłby stosunkowo tani w transporcie i montażu, co czyni go konkurencyjnym dla popularnych w budownictwie mieszkaniowym stropów gęstożebrowych, jednocześnie posiadając zalety stropów pełnych – dobre właściwości mechaniczne i akustyczne. W pracy przedstawiono zmodyfikowaną koncepcję takiego stropu, wykorzystującą jako nadbeton lekki beton kruszywowy, wraz z wybranymi wynikami analizy obliczeniowej.
Precast concrete manufacturers offer many solutions of partially or fully precast slabs, each of which performs better in one site usage conditions, and works worse in other situations. The advantages of precast structures are increasingly noticed by all participants of the construction process, including producers who want to satisfy the pressure from the construction market to develop newer, better and more hybrid solutions, so that competition with traditional concrete technology is possible. On Cracow University of Technology Scientists proposes making a slab made of pre-tensioned concrete elements of low thickness for use as shuttering for reinforced concrete made of lightweight concrete [9, 10], which is lighter than conventional traditional concrete by about 30%. The resulting composite slab of precast elements would be relatively cheap in transport and assembly, which makes them competitive for popular ribbed floor structures usually used in houses, at the same time having the advantages of solid slabs, such as good mechanical and acoustic properties. The work presents the modified concept of such slab and an example of analysis.
Źródło:
Builder; 2019, 23, 10; 9-11
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zabezpieczanie konstrukcji budynków przed skutkami wystąpienia obciążeń wyjątkowych
Protection of constructions of the buildings against accidental actions
Autorzy:
Dąbek, A.
Dyś, N.
Wyszyńska, K.
Zaniuk, I.
Szerafin, J.
Powiązania:
https://bibliotekanauki.pl/articles/390837.pdf
Data publikacji:
2013
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
konstrukcje żelbetowe
strop płaski
obciążenie wyjątkowe
reinforced concrete structures
flat slab
accidental action
Opis:
Zgodnie z wymaganiami normowymi, obiekty budowlane powinny być projektowane z uwzględnieniem ich zabezpieczenia przed skutkami obciążeń wyjątkowych, takich jak np. wybuch gazu czy uderzenie samochodem. Istniejące przepisy są w dużej mierze niejednoznaczne i dość enigmatyczne, brak jest również opracowań literaturowych szerzej opisujących to zagadnienie. W artykule przedstawiono podstawowe zasady projektowania budynków żelbetowych z uwzględnieniem zapisów normy PN-EN 1991-1-7:2008. Zaprezentowano wyniki obliczeń i ich analizę dla przykładowego stropu płaskiego, którego konstrukcja spełnia wymogi zabezpieczenia przed wystąpieniem zjawiska katastrofy postępującej.
In accordance with the requirements of construction standards, building structures should be designed taking into account their protection against accidental actions, such as gas explosions or car accidents. The current standards are largely inconclusive and quite enigmatic, there is also a deficiency in literature studies describing the issue. The article presents the basic procedures of design of the reinforced concrete buildings, including the requirements of the PN-EN 1991-1-7:2008 and the results of the calculations and analysis for a sample flat slab, whose structure meets the requirements of protection against the phenomenon of progressive collapse.
Źródło:
Budownictwo i Architektura; 2013, 12, 4; 51-60
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca statyczna stropów z płyt kanałowych w warunkach czterokrawędziowego oparcia
Static work of floor slabs made of hollow core slabs in conditions four-edge backrest
Autorzy:
Zając, Jakub
Drobiec, Łukasz
Jasiński, Radosław
Grzyb, Krzysztof
Kisiołek, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2202690.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta kanałowa
strop sprężony
praca statyczna
efekt długotrwały
badanie eksperymentalne
model badawczy
analiza obliczeniowa
hollow core slab
prestressed slab floor
statical work
long-term effect
experimental investigation
test model
computational analysis
Opis:
Stropy z płyt kanałowych pomimo ponad stu lat historii i miliarda metrów kwadratowych wykonanych tego typu konstrukcji w samej Europie nadal w pewnych aspektach projektowych budzą wątpliwości. W artykule przedstawiono wyniki wpływu krótkotrwałych i długotrwałych obciążeń na pełnoskalowy strop z płyt kanałowych o wymiarach 6,31 x 6,31 m. Badanie przeprowadzono pod niesymetrycznym obciążeniem grawitacyjnym, a ostatni pomiar wykonano po 665 dniach. Wykonana analiza obliczeniowa wykazała ponad trzykrotne przeszacowanie ugięć modelu płyty jednokierunkowej w odniesieniu do badań doświadczalnych. Przedstawiono uproszczone przestrzenne modele obliczeniowe, wraz z podaniem kryteriów stosowania. Badania i analizy wykazały, że powszechnie stosowana metoda obliczeniowa prowadzi do bardzo konserwatywnych wyników - nie oddając rzeczywistej charakterystyki pracy stropów z płyt kanałowych.
Despite over a hundred years of history and a billion square meters made in Europe alone, hollow-core slabs still raise doubts in some design aspects. The article presents the results of the short-term and long-term loads on a full-scale hollow-core slab with dimensions of 6.31 x 6.31 m. The test was carried out under an unsymmetrical gravity load, and the last measurement was carried out after 665 days. The computational analysis indicates over three times overestimated deflections of the one-way slab model compared to the experimental tests. Simplified spatial computational models are presented, along with application criteria. The research and the presented analyses have shown that the commonly used calculation method leads to very conservative results, without reflecting the actual performance characteristics of hollow-core slabs.
Źródło:
Przegląd Budowlany; 2022, 93, 11-12; 127--132
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nośności słupów żelbetowych w obszarze połączeń krawędziowych z płytą żelbetową
Experimental investigations of reinforced concrete columns in the edge connection zone with a reinforced concrete slab
Autorzy:
Urban, T.
Gołdyn, M.
Krawczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/390194.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
węzeł płytowo–słupowy
wytrzymałość efektywna
beton wysokowartościowy
płyta żelbetowa
słup
nośność
połączenie krawędziowe
column-slab connection
effective concrete strength
high strength concrete
reinforced concrete slab
column
load carrying capacity
edge connection
Opis:
W artykule przedstawiono i skomentowano wyniki własnych badań eksperymentalnych dotyczących krawędziowych połączeń płytowo – słupowych. Rozpatrywano mechanizm przekazywania oddziaływań pomiędzy słupami wykonanymi z betonu o wysokiej wytrzymałości a płytą stropową, która wykonana została z betonu zwykłego o wytrzymałości niemal pięciokrotnie niższej. Parametrem zmiennym w prezentowanych badaniach był wysięg wspornikowej części płyty. Stwierdzono istotny wpływ wspornika płytowego o niewielkim nawet wysięgu na wytrzymałość efektywną betonu słupa.
In this paper the results of the experimental investigations of edge column – slab connections are presented and commented on. The load transmission mechanism between high strength concrete columns and slab made of normal, five times lower strength concrete was considered. The variable parameter of presented study was the overhang of slab cantilever. The performed study showed important effect of slab cantilever on effective concrete strength of column in the connection zone.
Źródło:
Budownictwo i Architektura; 2014, 13, 3; 175-182
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parameter estimation of a discrete model of a reinforced concrete slab
Autorzy:
Abramowicz, M.
Berczyński, S.
Wróblewski, T.
Powiązania:
https://bibliotekanauki.pl/articles/280478.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
rigid finite element (RFE) model
reinforced concrete slab
estimation criteria
modal parameters
vibrations
Opis:
This paper presents parameter estimation of a mathematical model regarding natural vibrations of a reinforced concrete slab. Parameter estimation is based on experiments conducted on a real reinforced concrete slab. Estimated parameters include: substitute longitudinal modulus of elasticity of the reinforced concrete slab, which takes into account longitudinal reinforcement, effective thickness of the reinforced concrete slab and coefficient of damping. Using appropriate criteria during, the process of parameter estimation of the reinforcement concrete slab models has a great impact on obtaining precise results. The estimation criteria are selected in order to achieve consistency of natural vibration frequencies along with the Frequency Response Function measured during experiments with those calculated with the mathematical model. The model and all the calculations have been made using MATLAB programming environment.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 2; 407-420
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Construction disasters caused by punching in the support zone of reinforced concrete slab-and-column ceilings as well as means of their repair and reinforcement
Autorzy:
Kobielak, S.
Hutnik, E.
Zamiar, Z.
Powiązania:
https://bibliotekanauki.pl/articles/347252.pdf
Data publikacji:
2016
Wydawca:
Akademia Wojsk Lądowych imienia generała Tadeusza Kościuszki
Tematy:
disaster
building structure
punching in the support zone
slab-and-column ceiling
reinforcement
Opis:
Slab-and-column ceilings are widely used because of the considerable savings that they allow to obtain in the total construction cost. However, this structural system has a weak feature that consists of vulnerability to punching in a ceiling slab around its connection to a column. This paper describes several examples of disasters caused by slab punching and gives conclusions resulting therefrom. In order to eliminate the problem of punching, in the world there are used various types of shear reinforcement in a slab around a column, which are characterized by malleability and puncture resistance, thereby preventing a disaster. Examples of such reinforcement of ceiling slabs around columns are also shown in the work.
Źródło:
Zeszyty Naukowe / Wyższa Szkoła Oficerska Wojsk Lądowych im. gen. T. Kościuszki; 2016, 1; 151-167
1731-8157
Pojawia się w:
Zeszyty Naukowe / Wyższa Szkoła Oficerska Wojsk Lądowych im. gen. T. Kościuszki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Residual strength and toughness after impact loading for RC slabs strengthened with different layers of geogrid
Autorzy:
Ahmed, Aya M. E.
Hamdy, Osman
Saad, Youssef L. Z.
Ahmad, Seleem S. E.
Powiązania:
https://bibliotekanauki.pl/articles/36064265.pdf
Data publikacji:
2023
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
impact load
geogrid
RC slab
residual strength
static flexural load
toughness
toughness index
Opis:
This study presents an experiment for investigating the residual strength and toughness of reinforced concrete, RC, and slab reinforced by a geogrid as shrinkage reinforcement along with lower tensile steel reinforcement. Three different parameters were considered, slab thickness, number of geogrid layers, and thickness of the upper concrete cover. Fifteen slab samples with sizes of 50 × 50 cm exposed to the impact load on its center before being re-load by the static load and six slab samples exposed to the static load only. The load and deflection relation were recorded through the static loading process for all specimens, where loading capacity, toughness, and toughness index were measured. The results show an enhancement in the slabs residual strength as the slab thickness and concrete cover increased. On the other hand, the residual strength of slabs has a remarkable decrease with the increase in geogrid layers. Moreover, the toughness has a positive relationship with the concrete cover and has an inverse relation with the slab thickness and the number of layers. A geogrid reduced the number and distribution of cracks and mitigated their severity, especially for double layers with the same concrete cover.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2023, 32, 2; 117-134
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projektowanie budynków o konstrukcji żelbetowej słupowo-płytowej
Design of reinforced concrete slab-column buildings
Autorzy:
Moroz, Mateusz
Knyziak, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1860619.pdf
Data publikacji:
2021
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
projektowanie budynku
konstrukcja żelbetowa
konstrukcja słupowo-płytowa
model obliczeniowy
płyta stropowa
płyta fundamentowa
ściana
słup
building design
reinforced concrete structure
slab-column structure
calculation model
floor slab
foundation plate
wall
column
Opis:
Artykuł przedstawia techniki projektowania budynków o konstrukcji żelbetowej słupowo-płytowej jako zbioru elementów wydzielonych, bez wykorzystania BIM i modeli trójwymiarowych. Przedstawiono, w jaki sposób zbudowano model obliczeniowy płyty stropowej, płyty fundamentowej i tarczy ściennej z uwzględnieniem charakterystyk podatności. Scharakteryzowano problemy, na które natrafiono podczas prowadzenia obliczeń i analizy wyników oraz podano sposoby ich rozwiązania.
The article presents techniques for designing buildings with a reinforced concrete column-slab structure as a set of separated elements, without the use of BIM and models three-dimensional. The article presented how the calculation model of the floor slab, foundation slab and wall disc was constructed, taking into account the vulnerability characteristics. The problems encountered during the calculations and analysis of the results are characterized and the ways of solving them are given.
Źródło:
Przegląd Budowlany; 2021, 92, 3; 31-39
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strunobetonowe płyty kanałowe w stropie o nośności qk = 10 i 15 kN/m2 z równoczesnym ruchem dwóch wózków widłowych Qk = 20 kN każdy
Prestressed concrete hollow core slabs in the floor with the load capacity of qk = 10 and 15 kN/m2 with simultaneous movement of two forklift trucks Qk = 20 kN each
Autorzy:
Michałek, Jarosław
Łodo, Aleksy
Kozioł, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2142047.pdf
Data publikacji:
2022
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta kanałowa
strop
płyta strunobetonowa
wzmocnienie
eksploatacja
nośność
obciążenie graniczne
wózek widłowy
nadbeton
hollow core slab
prestressed concrete slab
floor
strengthening
exploitation
load capacity
limit load
forklift truck
concrete topping
Opis:
Przedmiotem artykułu jest weryfikacja nośności stropu magazynu surowców o wymiarach 90,0×12,5 m wykonanego z kanałowych płyt strunobetonowych o wysokości 265 mm i modularnej szerokości 1,20 m. Po ułożeniu płyt kanałowych na ścianach zewnętrznych i wewnętrznych piwnicy oraz wykonaniu wieńców i złączy podłużnych między płytami zauważono, że w obliczeniach do projektu stropu uwzględniono obciążenia zmienne qk = 10 i 15 kN/m2, zapominając o siłach skupionych wywoływanych przez dwa wózki widłowe o udźwigu Qk = 20 kN każdy. Wstrzymano prace wykończeniowe stropu w celu opracowania sposobu przystosowania go do przenoszenia obciążeń wymienionych wyżej. W artykule przedstawiono analizy, wnioski i zalecenia dotyczące możliwości uzyskania żądanej przez inwestora nośności stropu z równoczesną eksploatacją wózków widłowych. Wyniki analiz wykorzystano do opracowania projektu wzmocnień konstrukcji stropu na ścinanie i zginanie poprzez zespolenie płyt z nadbetonem będącym posadzką magazynu oraz dodatkowo na ścinanie przez wypełnienie betonem części przypodporowej kanałów w płytach na długości obliczeniowej lpt2 = 0,90 m przekazywania siły sprężającej z cięgien na beton.
The subject of the paper is verification of the load capacity of the floor of the raw material warehouse with dimensions of 90,0×12,5 m made of hollow-core prestressed concrete slabs 265 mm high and a modular width of 1,20 m. After placing the hollow-core slabs on the external and internal walls of the basement and making the tie beams and longitudinal joints between the slabs, it was noticed that in calculations for the detailed design of the floor with the live load qk = 10 and 15 kN/m2 no account was taken of the concentrated forces caused by two forklifts with a load capacity of Qk = 20 kN each. Finishing works of the ceiling were stopped in order to work out how to adapt it to transfer the loads mentioned above. The paper presents analyses, conclusions and recommendations concerning the possibility of obtaining the floor load capacity required by the investor with simultaneous use of forklifts. The results of the analysis has been used to strengthen the floor structure for shear and bending by joining the slabs with the 80 mm thick concrete topping. Additionally, higher shear capacity has been obtained by filling the supporting part of the channels (lpt2 = 0.90 m) with concrete at tendon transmission length.
Źródło:
Przegląd Budowlany; 2022, 93, 5-6; 105--111
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of rotation in an orthotropic elastic slab
Autorzy:
Santra, S.
Lahiri, A.
Das, N. C.
Powiązania:
https://bibliotekanauki.pl/articles/264403.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
orthotropic elastic slab
normal mode analysis
effect of rotation
płyta elastyczna
efekt rotacji
termoelastyczność
Opis:
The fundamental equations of the two dimensional generalized thermoelasticity (L-S model) with one relaxation time parameter in orthotropic elastic slab has been considered under effect of rotation. The normal mode analysis is used to the basic equations of motion and heat conduction equation. Finally, the resulting equations are written in the form of a vector-matrix differential equation which is then solved by the eigenvalue approach. The field variables in the space time domain are obtained numerically. The results corresponding to the cases of conventional thermoelasticity CTE), extended thermoelasticity (ETE) and temperature rate dependent thermoelasticity (TRDTE) are compared by means of graphs.
Źródło:
International Journal of Applied Mechanics and Engineering; 2017, 22, 1; 163-174
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical investigation and cost analysis of FRP concrete unidirectional hybrid slabs
Autorzy:
Mahboob, Amir
Eskenati, Amir Reza
Moradalizadeh, Soheil
Powiązania:
https://bibliotekanauki.pl/articles/2174188.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
płyta hybrydowa
symulacja numeryczna
konstrukcja betonowa
CFRP
GFRP
AFRP
hybrid slab
numerical simulation
costs
Opis:
Fiber-reinforced polymer (FRP) has been commonly used to reinforce concrete structures. The kinds of FRP demonstrate an effective alternative to various methods of reinforcement in concrete structures subjected to bad environmental conditions which cause corrosion and damage to concrete. Due to their lightweight, high strength, and high corrosion and fatigue resistance, Fiber Reinforced Polymer (FRP) composites have been widely applied in steel substitution during revitalization interventions. This paper presents numerical three-points bending tests on different models to investigate the effect of the reinforcements; Carbon, Glass, and Aramid fibers to find the corresponding cost of each one. Also, there is an available experimental model for verifying the results of the FEM that demonstrated broad agreement with the experimental statement, concerning the load-displacement curve. After validating the models, alternative designs such as type of the FRP, position of the FRP, and amount of the FRP usage were numerically tested to study the influence of each on the load-bearing capacity. The results showed that the best configuration would be one with GFRP and the load-bearing capacity is around 9kN in the optimum design.
Źródło:
International Journal of Applied Mechanics and Engineering; 2021, 26, 4; 156--166
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sprawdzenie prawidłowości założonych parametrów organizacyjnych i wydajnościowych procesu produkcyjnego sprężonych płyt kanałowych typu HC z uwzględnieniem warunków losowych
Checking the accuracy of parameters of the pre-tensioned hc slabs production process with reference to chance variations
Autorzy:
Nicał, A. K.
Grabowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/403241.pdf
Data publikacji:
2011
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
proces produkcyjny
płyta stropowa
analiza symulacyjna
warunki losowe
production process
slab
simulation analysis
chance wariations
Opis:
Celem referatu jest zbadanie, przy zastosowaniu metody symulacyjnej Monte Carlo, wpływu losowego rozkładu czasów trwania działań oraz operacji roboczych w ramach procesu produkcyjnego strunobetonowych wielootworowych płyt stropowych HC metodą ślizgową „Spiroll” na końcową wielkość parametrów produkcyjnych. Ciąg działań technologicznych występujących w całym procesie zobrazowano na schemacie technologiczno- funkcjonalnym, natomiast przykładowe czasy trwania działań roboczych pokazano na karcie operacji roboczej. Dodatkowo zdefiniowano przyczyny występowania różnych czasów trwania działań w ramach operacji roboczych i założono losowy ich rozkład. Wielkość dyspersji wokół wartości oczekiwanej na wykresie gęstości prawdopodobieństwa dla danej operacji roboczej uzależniona jest od jej stopnia mechanizacji. Uzyskane na podstawie badań rezultaty pozwalają stwierdzić, że założone na wstępie parametry organizacyjne i wydajnościowe są wysoce prawdopodobne to osiągnięcia.
The aim of the paper is to determine by means of the Monte Carlo simulation method the influence of random distributions of aggregated production activity durations, within the production process of pre-tensioned HC slabs using the Spiroll production system, on the production parameters. A sequence of technological activities is illustrated in the techno-functional diagram. The sample durations for production activities are shown on an operational schedule. Additionally, causes of the diverse durations of production activities have been defined. Depending on the degree of mechanization of production activities, the dispersion around the expected value of the assumed probability destiny functions can be larger or smaller. Obtained on the basis of the research results reveal that the production parameters, assumed at the beginning, are highly likely to achieve.
Źródło:
Budownictwo i Inżynieria Środowiska; 2011, 2, 3; 346-352
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strengthening of slab-column connections with CFRP strips
Wzmacnianie połączeń płyta-słup za pomocą taśm CFRP
Autorzy:
Urban, T.
Tarka, J.
Powiązania:
https://bibliotekanauki.pl/articles/230143.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wzmacnianie
połączenie płyta-słup
taśma kompozytowa
przebicie
CFRP
strengthening
slab-column connection
composite strip
punching
Opis:
The paper describes experimental research of slab-column connections examined on specimen designed as a part of reinforced concrete structure with flat slabs. The aim of the research was to verify the efficiency of slab reinforcement concept against punching shear by increasing slab's mechanical reinforcement ratio by applying additional external reinforcement in the form of carbon fiber reinforced polymer (CFRP) strips. The capacity enhancement in comparison to unstrengthened slab obtained 36%.
Artykuł przedstawia badania doświadczalne płyt żelbetowych, przyjętych jako fragment realnej konstrukcji żelbetowej z płaskimi stropami. Celem badań była weryfikacja efektywności wzmocnienia połączenia płyty ze słupem na przebicie poprzez zwiększenie mechanicznego stopnia zbrojenia (mocy zbrojenia) za pomocą dodatkowych zewnętrznych taśm karbodurowych (CFRP). Uzyskano wzrost nośności na przebicie do 36% względem modelu odniesienia.
Źródło:
Archives of Civil Engineering; 2010, 56, 2; 193-212
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O kształtowaniu konstrukcji dachu katowickiej hali Spodka. Rozważania z wywiadów z Profesorem Wacławem Zalewskim
About shaping the structure of Katowice Spodek-arena roof. Considerations from interviews with Professor Wacław Zalewski
Autorzy:
Pelczarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/294104.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
Spodek
tensegrity
praca płyty kołowej
momenty główne równoleżnikowe
structural behaviour of circular slab
circumferential moments
Opis:
Powyższy artykuł poświęcony jest rozważaniom na temat sposobów konstruowania ekonomicznych systemów stropowych i dachowych w oparciu o analizę pracy kołowej płyty zginanej podpartej ciągle na obwodzie. Spektakularnym rezultatem takich rozważań jest pierwotna konstrukcja dachu hali Spodka zaproponowana przez prof. Wacława Zalewskiego, która wniosła do zestawu rozwiązań dostępnych dla inżynierów i architektów pierwsze rozwiązanie z opatentowanej później rodziny typu tensegrity. W artykule przedstawiono również schematy ostatecznie zastosowanego roz wiązania konstrukcji dachu tego obiektu.
This article is about the methods of designing economic floor and roof structures based on the work of a circular bending plate, supported conti nually at the edge. A spectacular result of such considerations was the first tensegrity system defined by Prof. Wacław Zalewski which contributed to the set of solutions accessible to engineers and architects as the first solution of which later a patent was taken for the tensegrity type of group. The article also shows the final solution of the roof structure of the Spodek hall.
Źródło:
Architectus; 2013, 2(34); 69-82
1429-7507
2084-5227
Pojawia się w:
Architectus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of YLT method to estimate the load carrying capacity of one-way patched reinforced concrete slab under concentrated load
Autorzy:
Kristiawan, Stefanus Adi
Basuki, Achmad
Supriyadi, Agus
Santosa, Bambang
Marwoto, Sofa
Powiązania:
https://bibliotekanauki.pl/articles/45423983.pdf
Data publikacji:
2023
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
nośność
płyta jednokierunkowa
żelbet
load carrying capacity
one-way slab
patch repair
reinforced concrete
YLT
Opis:
An unsaturated polyester resin (UPR) mortar was applied to repair the damage to the tension zone's one-way reinforced concrete (RC) slabs. The load carrying capacity of the patched RC slab is of interest to justify the effectiveness of the repair. The Yield Line Theory (YLT) may be used to estimate the load carrying capacity of patched RC slabs under concentrated load. The results of the YLT are compared with the experimental results to evaluate the validity of the YLT method. The results confirm that patching alters the yield line formation, mainly when the concentrated load is applied close to the patching zone. Subsequently, the YLT method provides a higher load carrying capacity estimation deviation for slabs with a loading point near the patching zone. On the other hand, the YLT method estimates load carrying capacity accurately when the loading point is away from the patching zone.
Źródło:
International Journal of Applied Mechanics and Engineering; 2023, 28, 1; 47-57
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Popularność oraz kryteria wyboru systemów stropowych w Polsce, cz.1
Popularity and selection criteria of ceiling systems in Poland, part 1
Autorzy:
Kisiołek, A.
Powiązania:
https://bibliotekanauki.pl/articles/162946.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
system konstrukcyjny
strop monolityczny
strop gęstożebrowy
strop zespolony
strop kanałowy
strop sprężony
popularność
kryteria doboru
floor
structural system
monolithic floor
beam and block floor
composite floor
hollow core slab floor
prestressed slab floor
popularity
selection criteria
Opis:
Rynek systemowych produktów stropowych stanowi tematykę o charakterze techniczno-ekonomicznym, praktycznie nie podejmowaną przez ekonomistów. O ile publikuje się na tematy związane z kierunkami i trendami we współczesnym budownictwie, to dla menedżerów działających w tym segmencie rynku znana autorowi literatura nie dostarcza wielu danych. W części I artykułu przedstawiono wybrane wyniki badań dotyczące popularności poszczególnych systemów stropowych oferowanych na rynku polskim.
The market of systemic ceiling products constitutes a technical as well as economic subject, which is virtually ignored by economists. There are publications devoted to issues regarding directions and trends in modern building industry, for managers working in this market segment. Part I of the article presents selected test results regarding popularity of particular ceiling systems offered on the Polish market.
Źródło:
Przegląd Budowlany; 2017, 88, 5; 28-32
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identyfikacja stanu technicznego i prognozowanie bezpiecznej trwałości konstrukcji budynków wielkopłytowych
Identification of the technical condition and forecasting a safe durability the construction of buildings of large slab
Autorzy:
Tomaszewicz, D.
Obolewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/132055.pdf
Data publikacji:
2016
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
stan techniczny
prognozowanie
trwałość
konstrukcja
budynki wielkopłytowe
technical condition
forecasting
durability
construction
buildings of large slab
Opis:
W artykule analizowano zagrożenie trwałości konstrukcji budynków wielkopłytowych. Stan techniczny tych budynków jest zróżnicowany niezależnie od systemu wykonania. Głównymi czynnikami decydującymi o trwałości tego typu konstrukcji są jakość wykonania na etapie wytwórni prefabrykatów oraz dokładność montażu w miejscu wbudowania. Ogólnie trwałość konstrukcji tych budynków jako całości nie zagraża bezpieczeństwu jego lokatorów.
The article contemplated how real is the threat of the durability of the construction of buildings of large slab. The technical condition of these buildings is varied independently of the system execution. The major determining factors for the sustainability of this type of construction is the quality of execution of the stage factory precast and accuracy of assembly in place be built. Generally durability construction of these buildings as a whole does not threaten the safety of your tenants.
Źródło:
Modern Engineering; 2016, 1; 103-115
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Tests of the Vector II Slab in Field Conditions, Slab and Strip Model
Autorzy:
Zając, Jakub
Drobiec, Łukasz
Jasiński, Radosław
Wieczorek, Mirosław
Kisiołek, Artur
Powiązania:
https://bibliotekanauki.pl/articles/1838083.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
crack pattern
flexural analysis
interface
precast
slab
short-term load
pęknięcia
zginanie
prefabrykaty
płyty
obciążenie krótkotrwałe
Opis:
Vector II slab was tested on a natural scale (a slab with a dimension of 6.30 × 6.30 m) and a strip 6.30 m long and 1.20 m wide. The Vector II slab is built by precast panel 60 cm wide, 4 cm thick and 14-20 cm thick concrete overtopping on the construction site. The main purpose of the slab tests on a natural scale was to observe the "faulting" effect and temporary deflections. During the tests, the displacements in the area of the panel joints in the middle of the slab span were recorded. The maximum difference in displacement between adjacent panels of the slab model was 0.16 mm, and the vertical displacement was 1.9 mm. The strip model had no cracks that could indicate a interface cracks between the precast element and the concrete overlay. After completion of the field tests, the load was left on the slab model to verify long-term effects.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 1; 54-69
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Tests of the Vector II Slab in Field Conditions, Slab and Strip Model
Autorzy:
Zając, Jakub
Drobiec, Łukasz
Jasiński, Radosław
Wieczorek, Mirosław
Kisiołek, Artur
Powiązania:
https://bibliotekanauki.pl/articles/1838085.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
crack pattern
flexural analysis
interface
precast
slab
short-term load
pęknięcia
zginanie
prefabrykaty
płyty
obciążenie krótkotrwałe
Opis:
Vector II slab was tested on a natural scale (a slab with a dimension of 6.30 × 6.30 m) and a strip 6.30 m long and 1.20 m wide. The Vector II slab is built by precast panel 60 cm wide, 4 cm thick and 14-20 cm thick concrete overtopping on the construction site. The main purpose of the slab tests on a natural scale was to observe the "faulting" effect and temporary deflections. During the tests, the displacements in the area of the panel joints in the middle of the slab span were recorded. The maximum difference in displacement between adjacent panels of the slab model was 0.16 mm, and the vertical displacement was 1.9 mm. The strip model had no cracks that could indicate a interface cracks between the precast element and the concrete overlay. After completion of the field tests, the load was left on the slab model to verify long-term effects.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 1; 54-69
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reconstructing airport pavements using the technology of prefabricated concrete slab
Naprawa nawierzchni lotniskowych z wykorzystaniem technologii betonowej płyty prefabrykowanej
Autorzy:
Świerzewski, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/401986.pdf
Data publikacji:
2020
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
prefabricated slab
airport
load capacity
airport pavements
cement concrete
płyta prefabrykowana
lotnisko
nośność
nawierzchnie lotniskowe
beton cementowy
Opis:
This article presents the construction and technical concept for the use of an innovative repair of the airport pavement. It consists in embedding a prefabricated concrete slab in place of the excessively degraded surface of the existing slabs. In addition, the introduced technology of connecting adjacent panels together increases the spatial stiffness of the entire functional element and significantly increases the load-bearing capacity of the pavement. The results of laboratory and field tests presented in the article confirm the effectiveness of the technology used. As a result, the application of the reconstructing technology ensures the safety performance of aircraft operations at airports facilities.
W niniejszym artykule przedstawiona została konstrukcyjno-techniczna koncepcja dotycząca zastosowania nowatorskiej naprawy nawierzchni lotniskowej. Polega ona na wbudowaniu prefabrykowanej płyty betonowej w miejscu nadmiernie zdegradowanej nawierzchni płyt istniejących. Ponadto wprowadzona technologia połączenia ze sobą płyt sąsiednich zwiększa przestrzenną sztywność całego elementu funkcjonalnego oraz znacząco wpływa na wzrost parametru nośności nawierzchni. Przedstawione w artykule wyniki przeprowadzonych badań laboratoryjnych i poligonowych potwierdzają skuteczność zastosowanej technologii. W rezultacie stosowanie przedmiotowej technologii napraw zapewnia bezpieczne wykonywanie operacji statków powietrznych na obiektach lotniskowych.
Źródło:
Structure and Environment; 2020, 12, 3; 111-123
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Techniczne możliwości zbrojenia pianobetonowych płyt fundamentowych
Technical possibilities of foam concrete foundation slabs reinforcement
Autorzy:
Krzywoń, R.
Hulimka, J.
Jędrzejewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/104259.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
pianobeton
siatka CFRP
siatka BFRP
fundament płytowy
zbrojenie
foam concrete
CFRP grid
BFRP grid
slab foundation
reinforcement
Opis:
Właściwości fizyczne pianobetonu sprawiają, że świetnie sprawdza się on jako grubowarstwowy podkład pod fundamenty płytowe. Teoretycznie mógłby pełnić również rolę warstwy konstrukcyjnej, jednak, głównie z uwagi na duży skurcz powodujący niebezpieczeństwo niekontrolowanego samodylatowania się płyty, niezbędne jest stosowanie kilkucentymetrowej grubości płyty wierzchniej z betonu zwykłego zbrojonego siatką z prętów stalowych. Alternatywnym rozwiązaniem jest wprowadzenie zbrojenia, najlepiej odpornego na korozję, w strukturę pianobetonu. Artykuł przedstawia badania pilotażowe płyt pianobetonowych o gęstości 800 kg/m3, zbrojonych rusztami kompozytowymi z włóknem węglowym CFRP i bazaltowym BFRP. Dzięki wprowadzeniu takiego zbrojenia uzyskano kilkukrotny wzrost nośności na zginanie oraz znaczny wzrost sztywności. Badania wykazały również, że nawet całkowite pęknięcie próbki spowodowane skurczem nie ogranicza jej nośności, a poprzeczne żebra siatki zapewniają wystarczającą jej przyczepność.
Due to its physical properties foam concrete is a perfect material for construction of thick base for slab foundations. Theoretically, it could be also used as a structural layer, however, mainly due to significant shrinkage and resulting risk of self-division of slab it is necessary to apply a few-centimetre thick top slab made of OPC reinforced with steel bars. Alternatively, reinforcement – preferably corrosion-resistant – can be introduced into the structure of foam concrete. The paper presents pilot tests of foam concrete slabs of 800 kg/m3 density reinforced with composite grids made of carbon and basalt fibres. Thanks to application of such reinforcement flexural capacity of the slabs was increased almost 9 times in addition to an important increase in stiffness. The tests have also shown that even complete rupture of the specimen caused by shrinkage does not impair its load-bearing capacity and transverse ribs of the gird provide its sufficient anchorage.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 3/I; 341-350
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka ścian trójwarstwowych budynków wielkopłytowych
Diagnostics of three-layer walls of buildings of large slab
Autorzy:
Tomaszewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/111041.pdf
Data publikacji:
2017
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
budownictwo
diagnostyka techniczna
badania nieniszczące
budynki wielkopłytowe
building
technical diagnostics
non-destructive investigations
buildings of large slab
Opis:
Wraz z upływem czasu budynki wielkopłytowe w coraz w większym stopniu nie spełniają stawianych im wymogów i mają coraz gorszą opinię społeczną. Potrzebna jest ich modernizacja, która wymaga diagnostyki technicznej. W artykule scharakteryzowano badania nieniszczące wykorzystywane w diagnostyce technicznej budynków wielkopłytowych, które pozwalają ocenić obiekt budowlany, nie naruszając jego stanu konstrukcyjnego.
With the passage of time buildings of large slab more and more against them they do not meet the requirements and are becoming worse social opinion. There is a need of modernization, which requires technical diagnostics. The article describes non-destructive investigations used in the diagnosis of technical buildings of large slab that allow you to assess the construction works without prejudice to the status of construction.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2017, 2; 3-7
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problem nośności granicznej płyt żelbetowych w ujęciu aktualnych przepisów normowych
Ultimate limit state of reinforcement slabs in the light of standards presently in force
Autorzy:
Konderla, P.
Powiązania:
https://bibliotekanauki.pl/articles/163219.pdf
Data publikacji:
2010
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta żelbetowa
zbrojenie ortogonalne
nośność graniczna
moment zginający
reinforced concrete slab
orthogonal reinforcement
ultimate load capacity
bending moment
Opis:
Przedmiotem analizy jest płyta żelbetowa zbrojona ortogonalnie, parametryzowana układem współrzędnych {x,y} na powierzchni środkowej płyty. Zgodnie z procedurą stosowaną w praktyce projektowej dla przyjętego schematu statycznego i obciążenia wykonuje się analizę statyczną płyty traktowaną zwykle jako sprężystą, cienką płytę Kirchhoffa otrzymując w efekcie rozkład przemieszczenia i sił wewnętrznych. W przypadku stosowania do analizy metody numerycznej MES, otrzymuje się rozwiązania w postaci dyskretnej. Kolejnym etapem jest wymiarowanie płyty, co w praktyce sprowadza się do doboru zbrojenia płyty, tak aby spełnione były warunki stanu granicznego zgodnie z obowiązującymi normami.
The problem of reinforcement slab design under conditions of ultimate limit state I is analyzed in the light of living up to the regulations of relevant standards. The differences in the regulations between these standards are among the chief reasons for obtaining different quantities of reinforcements during application. Using the standards in question, the algorithms for reinforcement design are compared by analyzing the equivalent bending moments, which are fundamental to the calculations of reinforcement slabs.
Źródło:
Przegląd Budowlany; 2010, R. 81, nr 2, 2; 51-56
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of slab formwork of monolithic reinforced concrete buildings
Dobór deskowań stropowych do realizacji budynków monolitycznych
Autorzy:
Radziejowska, Aleksandra
Sobotka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/231244.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
deskowanie stropowe
budynek monolityczny
konstrukcja żelbetowa
analiza wielokryterialna
slab formwork
monolithic building
reinforced concrete structure
multi-criteria analysis
Opis:
Paper presents the issue related to the selection of slab formwork taking into account the criteria that are currently the most important The in the process of the construction project execution. The analysis included selected, modern system solutions, which significantly accelerate the tempo of reinforced concrete works and, as a consequence, increase the effectiveness of the construction project execution. The innovative system of drop heads, which the analysed slab formwork is equipped with, is offered by various formwork producers. The offered solutions, however, differ not only in the construction of the drophead itself, but also in the arrangement and variety of other system elements, as well as the scheme of their operation, which may ultimately significantly affect the effectiveness of their application. For that reason, the choice of formwork for specific buildings should be made from among carefully analysed several variants of the wide market offer. The paper presents the results of analysis and evaluation of formwork systems with dropheads according to the proposed methodology, including multi-criteria analysis.
Podjęty problem wynika z potrzeb praktyki budowlanej. Dotyczy wyboru systemów deskowań do wykonywania budynków w technologii żelbetowej monolitycznej. Praktyka wskazuje, że jakkolwiek dostawca deskowań zapewnia projekt deskowania (często i zespół montażystów) to nie zawsze jest to najkorzystniejsza oferta dla realizacji obiektu z jego specyficznymi uwarunkowaniami realizacyjnymi. W artykule przedstawiono metodykę wyboru deskowań stropowych z głowicami opadowymi spośród oferowanych systemów przez producentów.
Źródło:
Archives of Civil Engineering; 2020, 66, 1; 127-141
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The thermal quality of construction joints with the balcony slab
Autorzy:
Pawłowski, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/2174984.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
konstrukcja energooszczędna
jakość cieplna elementów budowlanych
płyta balkonowa
energy-saving construction
thermal quality of building elements
balcony slab
Opis:
The article introduces selected aspects of creating material sets for an external wall connection with a balcony slab. The integral part of this work are calculations and analyses concerning the thermal quality of joints with balcony slabs produced using various construction and material solutions. Proper selections of the material layers of a building case in regards to thermal aspects and humidity essentially influence the building demand for energy (EU, EK i EP) and pollutant emissions into the natural environment.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2021, 10, 2; 23--30
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budynki wykonane w systemie OWT - 67 w układzie urbanistycznym osiedla „Maki” w Lublinie
Buildings constructed in the system OWT- 67 in urban layout of residential settlement "Maki" in Lublin
Autorzy:
Janusz, R.
Janus, K.
Powiązania:
https://bibliotekanauki.pl/articles/390467.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
OWT-67
wielka płyta
osiedle Maki
Kośminek
Spółdzielnia Mieszkaniowa Kolejarz
concrete slab
Maki District
Kośminek District
Kolejarz Housing
Opis:
Osiedle Maki powstało w połowie lat 70-tych w kwartale zabudowy ograniczonym ulicami Droga Męczenników Majdanka, ul. Krańcową, ul. Lotniczą, ul. Głuską, jako kolejny etap rozbudowy zasobów mieszkaniowych miasta. Istotnym elementem było usytuowanie nowej zabudowy na obszarze wcześniej urbanizowanym – tzw. stary Kośminek. Powstał w ten sposób układ mieszany, gdzie prostym, długim, usytuowanym równolegle do siebie 5-kondygnacyjnym budynkom wielorodzinnymi i 11-kondygnacyjnym punktowcom o wyraźnie modernistycznej formie i sposobie sytuowania budynków towarzyszy zabudowa jednorodzinna lokowana wzdłuż ulic. Przedstawiono uwarunkowania urbanistyczne i funkcjonalne budynków 5-kondygnacyjnych wybudowanych w systemie OWT-67. Opisano przemiany urbanistyczne osiedla na przestrzeni blisko 40 lat (obsługa parkingowa, zieleń). Przeprowadzono analizę potrzeb i możliwości w zakresie kolejnych działań mogą-cych poprawić jakość życia mieszkańców osiedla w kontekście ograniczeń wynikających z uwarunkowań własnościowych, ekonomicznych i konstrukcyjnych. Zasadnymi działaniami wydaje się kontynuacja termomodernizacji budynków. Kompleksowego działania wymaga poprawa jakości przestrzeni między budynkami – dalsza wymiana nawierzchni utwardzonych, poprawa jakości zieleni, uwzględnienie w aranżacji terenów potrzeb zróżnicowanych wiekowo grup użytkowników osiedla ze szczególnym uwzględnieniem seniorów i rozwiązanie problemu parkowania samochodów ze wskazaniem na konieczność budowy garaży podziemnych.
“Maki” residential settlement was established in the mid-70s, in the quarter of construction it was limited by Droga Męczennikow majdanka, Krańcowa, Lotnicza and Gluska Streets, as the subsequent stage of development of minicipal housing stock. A crucial issue concerned the location of a new building in a previous urbanized area – the so called Kosminek. As a result, a mixed system was created, where simple, tall and parallely situated to each other 5-story multifamily buildings and an 11-storey point tower of an evident modernistic form and the way of their location are accomposed by a simple-family housing placed along the streets. The urban and funtional conditions in 5-storey buildings constructed in OWT-67 system were presented. The urban changes of settlement over nearly 40 years (parking sevice, greenery) were discussed. The analysis of the needs and possibilities in terms of next steps which can improve the living quality of residents in aspect of restrictions consequent upon ownership, economic and construction determinants was complited. Justified steps refer to the continuation of building termomodernization. The improvement of space quality between building is the highest priority. Not to mention, further exchange of paved surface, the enhancement of greenery quality concerning the needs of divers age groups of residents in the arrangement of problem indicating the necessity to build underground garages.
Źródło:
Budownictwo i Architektura; 2014, 13, 3; 299-307
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skutki uproszczeń w modelowaniu mostowych przęseł płytowych z betonu
Effects of simplifications in modeling bridge slab spans made of concrete
Autorzy:
Chełstowski, Łukasz
Oleszek, Radosław
Radomski, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/24024806.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
most płytowy
modelowanie komputerowe
model numeryczny MES
wiadukt drogowy
slab bridges
computer modelling
FEM numerical model
road viaduct
Opis:
Płytowe przekroje poprzeczne przęseł są rozwiązaniem często stosowanym w drogowych obiektach inżynierskich. Ich analizę na podstawie teorii dźwigarów umożliwia w praktyce projektowej metoda elementów skończonych (MES). Przed upowszechnieniem się techniki komputerowej stosowano modele jednobelkowe z rozdziałem poprzecznym obciążenia. Przekroje płytowe często odwzorowuje się za pomocą rusztów belkowych. W artykule przedstawiono obliczenia porównawcze wiaduktów płytowych ze sparametryzowanymi, zróżnicowanymi rozpiętościami, szerokościami i kątami skosów przęseł. Wykazane rozbieżności szacowania wielkości statycznych za pomocą modeli numerycznych różnej dokładności, świadczą o wpływie klasy odwzorowania komputerowego na uzyskiwane wartości i potencjalne skutki uproszczeń stosowane w projektowaniu.
Plate cross-sections of spans are often used in road engineering facilities. In design practice, the method of finite elements (MES) enables their analysis based on the theory of girder. Before the dissemination of computer technique, one -bar models with a transverse chapter were used. Plate cross-sections are often reproduced with beam grates. The article presents comparative calculations of plate viaducts with parameterized, varied spans, widths and slants of span. The discrepancies of estimating static quantities using numerical models of various accuracy testify to the impact of the computer mapping class on the values obtained and the potential effects of simplifications used in design.
Źródło:
Drogownictwo; 2022, 9; 311--322
0012-6357
Pojawia się w:
Drogownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of stiffness and energy dissipation for the models of reinforced-concrete composite slabs based on the investigations of statically loaded slabs
Autorzy:
Gromysz, K.
Powiązania:
https://bibliotekanauki.pl/articles/230186.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
płyta żelbetowa
płyta kompozytowa
pętla histerezy
rozpraszanie energii
sztywność
reinforced concrete
composite slab
hysteresis loop
energy dissipation
stiffness
Opis:
Reinforced concrete composite slab consists of a thin prefabricated slab in which span reinforcement is located and of concrete joined with the slab, with such concrete being laid on site. The existence of a joint of two concretes in such floors is interpreted as introducing a contact layer into a monolithic slab. In the paper parameters of two models are estimated. The first is a model of a contact layer and the second is a model of a composite slab with a single degree of freedom. The models consider that the contact has elastic properties and inelastic properties causing energy dissipation. Experimental investigations are discussed further based on which the parameters values of the contact layer model were determined. Delamination was experienced for the slabs characterised by low contact layer stiffness after applying a maximum load. In addition, the strains of a contact layer having low stiffness are accompanied by lower energy dissipation than of a layer with high stiffness. The smaller stiffness of composite floors, as compared to monolithic floors, occurs as a consequence of the existence of a joint. Such decrease for a composite slab is interpreted in the model with a single degree of freedom as the serial connection of stiffness of a monolithic slab and an element considering the existence of a contact layer. The stiffness of an element considering the existence of a contact layer decreases along with a load, and the elements corresponding to the higher stiffness of the contact layer are characterised by higher energy dissipation. The aforementioned results of the investigations confirm the assumptions of the contact layer model and a composite slab model with a single degree of freedom. The findings made represent a basis for establishing a method of evaluating the condition of a joint in composite slabs according to statistical investigations.
Źródło:
Archives of Civil Engineering; 2012, 58, 3; 259-292
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of GPR and TLS data for the assessment of the bridge slab geometry and reinforcement
Autorzy:
Cafiso, S.
Di Graziano, A.
Goulias, D.
Mangiameli, M.
Mussumeci, G.
Powiązania:
https://bibliotekanauki.pl/articles/230272.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
georadar
skanowanie laserowe naziemne
płyta mostowa
geometria
zbrojenie
ground penetrating radar
terrestrial laser scanning
bridge slab
geometry
reinforcement
Opis:
This paper presents a suggested approach for forensic investigation of bridge decks in which Ground penetrating radar (GPR) consisting of two antennas is used to assess the current conditions. The methodology was tested on a bridge deck in central Sicily. The acquired data were analyzed for identifying the asphalt overlay thickness, concrete cover depth and deck thickness and location of the rebar reinforcement. In the proposed approach for assessing bridge deck conditions the GPR survey was complemented with (i) a site investigation on layer thicknesses for calibration/verification purposes of the GPR response and (ii) a Terrestrial Laser Scanning system (TLS) to verify the bridge design slab curvature. The study shows that this methodology has significant merits on accurately assessing such bridge deck components when bridge design records are non-existing, and by using non-invasive methods such as laser scanning and GPR. The great advantage provided by the TLS technique is the possibility to obtain a 3D output model of the scanned element with the accuracy of the best topographic instruments in order to complement GPR data surveys for bridge inspection.
Źródło:
Archives of Civil Engineering; 2020, 66, 1; 297-308
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nośność płyt kanałowych na ścinanie w konstrukcjach typu Slim Floor
Load-bearing capacity of hollow slabs to cutting in Slim Floor constructions
Autorzy:
Bodzak, P.
Powiązania:
https://bibliotekanauki.pl/articles/162294.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop
konstrukcja
Slim Floor
płyta kanałowa
oparcie
odporność na ścinanie
floor
structure
hollow core slab
supporting
shear resistance
Opis:
W artykule na podstawie wyników badań modeli w skali naturalnej przeanalizowano wpływ zastosowania stalowych belek kapeluszowych WQ oraz Deltabeam w układach stropów typu Slim Floor na nośność na ścinanie sprężonych płyt kanałowych. Wykazano, że oprócz podatności belek istotny wpływ na siły niszczące mają warunki podparcia płyt HC na pasach dolnych stalowych belek kapeluszowych.
Based on results of research of models in the natural scale, the article analyzes the impact of application of steel WQ hat beams as well as Deltabeam in layouts of Slim Floor constructions on the load-bearing capacity to cutting of prestressed hollow slabs. The research has indicated that apart from susceptibility of the beams, a significant impact on the destructive forces is exerted by conditions of support of the HC slabs on lower bands of steel hat beams.
Źródło:
Przegląd Budowlany; 2018, 89, 7-8; 34-39
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczanie stanów granicznych stropów gęstożebrowych w funkcji obciążenia i rozpiętości
Autorzy:
Bednarek, Jerzy Piotr
Powiązania:
https://bibliotekanauki.pl/articles/163257.pdf
Data publikacji:
2020
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
strop żelbetowy
strop sprężony
stan graniczny
obciążenie
rozpiętość
reinforced concrete floor
prestressed slab floor
limit state
load
range
Źródło:
Przegląd Budowlany; 2020, 91, 1; 44-47
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of thermal loads on modern road concrete pavements in Poland
Autorzy:
Brodzik, R.
Powiązania:
https://bibliotekanauki.pl/articles/196643.pdf
Data publikacji:
2017
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
numerical modelling
thermal loads
concrete slab
temperature
continuously reinforced concrete pavement
modelowanie numeryczne
obciążenia cieplne
płyta betonowa
temperatura
Opis:
This article presents the opportunities for the development of road concrete pavements in Poland. The analysis of the prospects for evolving a new type of concrete pavement, based on continuous reinforcement, has been performed. The advantages and disadvantages, in terms of functionality, strength and economy, have been analysed. The evaluation of stress and displacements in the analysed continuously reinforced concrete slabs, involving the use of the finite element method (FEM), has been performed on selected temperature distributions derived from thermal loads. Based on the analysis of adopted decompositions, the use of the FEM to assess the effectiveness of the continuously reinforced pavements has been proposed.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2017, 95; 27-37
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola zasypek krystalizatorowych w procesie ciągłego odlewania stali
The role crystallization of mould powders used in the continuous casing of steel
Autorzy:
Sorek, A.
Ostrowska-Popielska, P.
Powiązania:
https://bibliotekanauki.pl/articles/181628.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Metalurgii Żelaza im. Stanisława Staszica
Tematy:
ciągłe odlewanie stali
zasypka krystalizatorowa
smarowanie powierzchni wlewka
continuous casting of steel
mould powder
lubrication of slab surface mold
Opis:
W artykule scharakteryzowano proces ciągłego odlewania stali ze szczególnym uwzględnieniem roli zasypek krystalizatorowych. Scharakteryzowano również ciekłą żużlotwórczą fazę zasypek krystalizatorowych oraz zjawisko smarowania powierzchni wlewka w krystalizatorze.
In the presents works characterize the role crystallization of mould powder used in the continuous casting of steel. Describe also liquid phase slag's of mould powder and lubrication's phenomena of slab surface mold in crystallizer.
Źródło:
Prace Instytutu Metalurgii Żelaza; 2012, T. 64, nr 2, 2; 18-22
0137-9941
Pojawia się w:
Prace Instytutu Metalurgii Żelaza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Warunki formowania się martwej strefy i jej wielkość dla ziarna katalizatora o kształcie płyty płaskiej
Conditions of dead zone formation and its size for a slab catalyst grain
Autorzy:
Król, G.
Szukiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/2072409.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
martwa strefa
ziarno katalizatora o geometrii płaskiej
krytyczna wartość modułu Thielego
dead zone
slab catalyst pellet
critical Thiele modulus
Opis:
Martwa strefa to część ziarna katalizatora, w której najczęściej z powodu wyczerpania się jednego z reagentów reakcja nie biegnie. Taki przypadek może zachodzić dla kinetyk spełniających określone warunki oraz modułu Thielego większego od wartości krytycznej Φkr. W pracy przedstawiono wzór, którego zastosowanie wraz z technikami numerycznymi pozwala na szybkie i proste obliczenie Φkr dla ziarna o geometrii płaskiej i dla równania kinetycznego dowolnego typu. Zgodność z wynikami dostępnymi w literaturze potwierdza poprawność wyprowadzonej zależności.
A dead zone is a part of catalyst pellet where the chemical reaction usually stops due to vanishing concentration of one of reactants. It can happen when the kinetic equation satisfies certain conditions and when the Thiele modulus is greater than its critical value, Φkr. In this paper a formula which allows the fast and simple computation of Φkr for a slab catalyst pellet and for any type of kinetic equation was derived. The correctness of derived formula is confirmed by its compatibility with the results available in literature.
Źródło:
Inżynieria i Aparatura Chemiczna; 2013, 4; 347--348
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigation on punching behavior of thick reinforced concrete slabs
Autorzy:
Urban, T.
Gołdyn, M.
Krakowski, J.
Krawczyk, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/231142.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
beton
płyta żelbetowa
przebicie
ścinanie
smukłość
naprężenie ścinające graniczne
concrete
reinforced concrete slab
punching
shear
slenderness
ultimate shear stress
Opis:
The results of experimental test of nine thickset reinforced concrete slabs in punching are presented in the this paper. The aim of the tests was verification of the Eurocode EC 2 procedure, by which the ultimate shear stresses vRd,c depend on the slenderness of the slab. Besides of the performed tests results, the analysis of the foreign investigation of the fundaments is also included. The test results, as well as other tests, show the correctness of the function assumed in Eurocode 2, which gives correlation between ultimate stresses vRd,c and shear slenderness.
Źródło:
Archives of Civil Engineering; 2013, 59, 2; 157-174
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical study on the behaviour of composite space truss structures with openings in a concrete slab
Autorzy:
Sangeetha, Palanivelu
Powiązania:
https://bibliotekanauki.pl/articles/396637.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
composite structure
space truss
slab openings
maximum load
maximum deflection
ANSYS
konstrukcje kompozytowe
kratownice przestrzenne
płyty
maksymalne obciążenie
ugięcie
Opis:
A space truss structural system is a three-dimensional arrangement of linear elements in a pyramid pattern forming a Double Layer Grid (DLG) system. Space trusses are an elegant and economical means of covering larger areas such as roof systems, in a wide variety of applications such as a stadium, aircraft-hanger, assembly hall, etc. The major problem encountered in using the space truss as a roofing system is the sudden failure of the whole structure due to critical buckling of the top chord member. Earlier research has shown that the optimal solution to overcome such a failure is by providing a small thickness of concrete slab over the space truss, so that the space truss with concrete slab (Composite Space Truss) will act as a floor system for the multi-storey building. For better ventilation and lighting in the building, the need for openings in the composite space truss is unavoidable; however, providing an opening in the concrete slab will reduce the load carrying capacity of the structure. The analysis of a composite space truss of size 30m x 30m with all possible locations of openings for four different support conditions was carried out using ANSYS in order to study the load - deflection behaviour. Further, the ductility factor and energy absorption capacity of the composite space truss with different locations of slab openings were compared.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 3; 265-280
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt konstrukcji garażu wielokondygnacyjnego
Structural design of multi-storey garage
Autorzy:
Klimasara, Jan
Gnatowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/161347.pdf
Data publikacji:
2020
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
garaż wielokondygnacyjny
projekt
modelowanie
wymiarowanie
płyta stropowa
słup
fundament
multi-storey garage
design
modelling
dimensioning
floor slab
column
foundation
Opis:
Garaże wielokondygnacyjne to jeden ze sposobów rozwiązania problemów z parkowaniem samochodów osobowych w dużych aglomeracjach. Zaproponowano autorską koncepcję architektoniczną obiektu oraz rozwiązania funkcjonalne. Analizie poddano wydzielony fragment konstrukcji, ze szczególnym uwzględnieniem stref podporowych układu płytowo-słupowego, rozważając różne sposoby modelowania numerycznego. Wymiarowanie, zgodne z wymaganiami eurokodów, przeprowadzono metodami analitycznymi oraz z wykorzystaniem programów komputerowych.
Multi-storey garages are one way to solve problems with parking cars in large agglomerations. Proprietary architectural concept of the object and functional solutions have been proposed. A separate fragment of the structure was analyzed with particular emphasis on support zones of the plate-column system. Various methods of numerical modeling were considered. Designing in accordance with the requirements of Eurocodes was carried out by analytical methods and using computer programs.
Źródło:
Przegląd Budowlany; 2020, 91, 1; 38-43
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polski rynek rozwiązań stropowych – najpopularniejsze systemy, cz.1
Flooring systems in Poland – popular solutions part 1
Autorzy:
Kisiołek, A.
Powiązania:
https://bibliotekanauki.pl/articles/160747.pdf
Data publikacji:
2017
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
Polska
system stropowy
konstrukcja żelbetowa
strop monolityczny
strop płytowy
strop belkowo-płytowy
strop kompozytowy
strop prefabrykowany
strop belkowo-pustakowy
popularność
Polska
floor system
reinforced concrete structure
monolithic floor
slab floor
beam and slab floor
composite floor
prefabricated floor
beam and block floor
popularity
Opis:
Celem niniejszego artykułu jest prezentacja popularnych w Polsce systemów stropowych, w tym również rozwiązań najnowszych, których stosowanie przynosi określone korzyści zarówno pod kątem technicznym, funkcjonalnym, jak i ekonomicznym. W pierwszej części niniejszej publikacji zostaną omówione: gęstożebrowy strop zespolony Vector, stropy monolityczne oraz gęstożebrowe stropy belkowo-pustakowe.
The aim of this article is to present the most popular flooring systems in Poland, including the latest solutions, whose application brings certain technical, functional and economical advantages. In the first part of this paper, we will discuss: Vector rib-and-slab floor, monolithic ceiling and beam and block flooring systems.
Źródło:
Przegląd Budowlany; 2017, 88, 12; 25-29
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Betony lekkie w konstrukcjach sprężonych
Use of lightweight concrete to prestress
Autorzy:
Mieszczak, M.
Szydłowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/129139.pdf
Data publikacji:
2017
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
beton lekki
konstrukcja sprężona
właściwości
płyta kablobetonowa
analiza numeryczna
lightweight concrete
prestressed construction
properties
post-tensioned concrete slab
numerical analysis
Opis:
W pracy przedstawiono wybrane badania betonu lekkiego określające jego właściwości mechaniczne oraz ich wpływ na straty siły sprężającej w odniesieniu do podobnych badań betonu zwykłego. W celu zobrazowania problemu przedstawiono porównanie analizy numerycznej płyty sprężonej kablobetonowej z betonu lekkiego z taką samą z betonu zwykłego. Prosta analiza ugięć elementu pokazuje korzystny wpływ stosowania betonu lekkiego.
The paper presents selected research lightweight concrete, defining the properties and the impact on the loss of compression. Presents numerical analysis of the prestress slab lightweight concrete and plain, which show that the use of lightweight concrete can reduce the slab deflection.
Źródło:
Builder; 2017, 21, 7; 90-93
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Relationship of the interaction load capacity of anchors on their number and anchoring system
Autorzy:
Baryłka, A.
Tomaszewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/2175740.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
bonded anchors
epoxy resin
anchoring system
large slab panel buildings
kotwy wklejane
żywica epoksydowa
system kotwienia
budynki z płyt wielkopłytowych
Opis:
Purpose: The article presents the possibilities of using anchoring systems in the walls of three-layer large slab panel buildings. The use of diagonal anchors allows to increase the effective anchorage depth, which significantly increases the durability of the façade textured layer. Design/methodology/approach: Pilot tests have confirmed the necessity to use an anchor system in various configurations. Findings: The documents used included the conclusions of the pilot tests on the real object and the main experimental tests carried out on concrete samples. Research limitations/implications: The design of new anchorage systems and the proposed theoretical models for estimating their theoretical load capacity are based on the Guidelines contained in the European Technical Approvals. Practical implications: Single bonded anchorages used in engineering practice require evaluation in order to increase the durability of larger areas of the façade textured layer. Originality/value: The possibility of differentiating system anchors makes it possible to use them in very thin structural layers (diagonal anchors).
Źródło:
Archives of Materials Science and Engineering; 2021, 112, 2; 55--62
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of methods of monitoring structure deformations based on tests of a column-plate slab
Porównanie metod monitorowania odkształceń konstrukcji na podstawie badań stropu słupowo-płytowego
Autorzy:
Nykiel, Damian
Powiązania:
https://bibliotekanauki.pl/articles/1955928.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
mesurement
deformations
column-plate slab
electrofusion strain gauge
fiber optic gauge
pomiary
odkształcenia
strop słupowo-płytowy
tensometr elektrooporowy
tensometr światłowodowy
Opis:
This work includes a comparison of the methods of monitoring the deformations of a structure on the example of a flat plate slab test. Classic ESG (electrofusion strain gauges) and modern DFOS (distributed fiber optic sensors) were compared. During the research, both types of sensors were used on some of the reinforcing bars. The study aims to indicate the differences between the compared monitoring methods, both in terms of the obtained results and their utility values.
Źródło:
Budownictwo i Architektura; 2021, 20, 4; 5-16
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O obliczeniach płyt fundamentowych
On calculations of foundation slabs
Autorzy:
Ambroziak, A.
Górski, K.
Powiązania:
https://bibliotekanauki.pl/articles/163657.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta fundamentowa
wymiarowanie
zbrojenie
obliczanie
analiza numeryczna
sposób przyłożenia obciążenia
foundation slab
dimensioning
reinforcement
calculation
numerical analysis
load application method
Opis:
W pracy przedstawiono analizę wpływu sposobu przyłożenia obciążenia na wyniki wymiarowania zbrojenia w płycie fundamentowej. Dodatkowo autorzy dokonali krótkiego przeglądu literatury z zakresu płyt fundamentowych.
The paper presents the analysis of influence of the load application method on the results of sizing up of reinforcement in the foundation slab. In addition, the authors have prepared a brief review of literature in the scope of foundation slabs.
Źródło:
Przegląd Budowlany; 2018, 89, 5; 24-27
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of load level of corner columns on punching shear resistance of flat slabs
Wpływ obciążenia słupa narożnego na nośność płyt płaskich z uwagi na przebicie
Autorzy:
Gołdyn, Michał
Urban, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/390819.pdf
Data publikacji:
2020
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
column-slab connection
punching shear
lateral expansion
membrane action
normal stress
połączenia płyta-słup
przebicie
odkształcenia poprzeczne
efekt membranowy
naprężenia normalne
Opis:
The problem related to the effect of the corner column load on the punching shear resistance of the slab was presented. Existing experimental studies on internal columns demonstrated that the column pressure could lead to an increase in the punching shear resistance. Because of different confinement conditions of corner column-slab connection joints, it is unclear if such an effect exists for corner columns. New experimental investigations were initiated to clarify this issue. They covered a total of three corner column-slab connection specimens – slabs with a thickness of 140 mm and a longitudinal reinforcement ratio ρl = 1.09% connected with columns of a cross-section of 200×200 mm. The only variable parameter was the column load equal to 500, 1000 and 1500 kN. A reduction of the slab load-carrying capacity of about 9% due to a three-fold increase in the column load was noted. Therefore, the effect of the column load turned out to be opposite to that observed for most previous tests on internal column-slab connections, which could have a result of a limited capacity of the slab reinforcement due to additional tensile forces from the lateral expansion of joint concrete. Comparison in the light of test results demonstrated, that EN 1992-1-1 procedure allowed for safe, yet conservative estimation of the punching shear resistance. An average ratio of experimental to theoretical load of 1.82 was obtained.
W artykule przedstawiono zagadnienie wpływu obciążenia słupa narożnego na nośność płyty na przebicie. Dotychczasowe, nieliczne badania eksperymentalne dotyczące słupów wewnętrznych wykazały, iż nacisk słupa może prowadzić do zwiększenia nośności na przebicie. Z uwagi na odmienne warunki skrępowania węzłów skrajnych połączeń płytowo-słupowych konieczne było jednak zweryfikowanie tego efektu w odniesieniu do slupów narożnych. W tym celu wykonano i zbadano trzy modele połączeń płytowo-słupowych, wykonanych w skali. Wszystkie modele charakteryzowały się jednakową geometrią i zbrojeniem. Płyty o grubości 140 mm i stopniu zbrojenia podłużnego ρl = 1,09% połączone były ze słupami o przekroju 200×200 mm. Jedyny parametr zmienny stanowiło obciążenie słupa, równe 500, 1000 oraz 1500 kN. Wskutek trzykrotnego zwiększenia obciążenia słupa odnotowano zmniejszenie nośności na przebicie o około 9%. Efekt obciążenia słupa na nośność płyty okazał się zatem przeciwny do obserwowanego w przypadku większości badań połączeń wewnętrznych, czego przyczyny należy upatrywać w ograniczeniu nośności zbrojenia podłużnego płyty ze względu na odkształcenia poprzeczne betonu węzła. Porównanie wyników badań z obliczeniami według EN 1992-1-1 wykazało, iż procedura normowa pozwoliła na bezpieczne, aczkolwiek konserwatywne oszacowanie nośności modeli. Uzyskano bowiem średni stosunek nośności eksperymentalnej do teoretycznej równy 1,82.
Źródło:
Budownictwo i Architektura; 2020, 19, 3; 44-56
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O wpływie wielkości pewnego osłabienia podłoża w zagadnieniu Westergaarda
On the influence of the size of certain weakness of foundation in the Westergaard problem
Autorzy:
Gilewski, W.
Nagórska, M.
Powiązania:
https://bibliotekanauki.pl/articles/249646.pdf
Data publikacji:
2013
Wydawca:
Instytut Naukowo-Wydawniczy TTS
Tematy:
płyta drogowa
nawierzchnia betonowa
naprężenia płyty
przemieszczenia płyty
zagadnienie Westergaarda
road slab
concrete road surface
plate displacements
plate stresses
Westergaard problem
Opis:
We wcześniejszej pracy autorów [3] zbadano wpływ pewnego typu osłabień podłoża pod płytą nawierzchni drogowej sztywnej w zagadnieniu Westergaarda [1,2], tj. określeniu maksymalnych ugięć i maksymalnych naprężeń w płycie prostokątnej sprężystej spoczywającej na podłożu Winklera w przypadku obciążenia kołem pojazdu w trzech położeniach: w narożu, na środku i przy krawędzi płyty. Jako osłabienie podłoża przyjęto jego brak na powierzchni prostokątnej równej 1/9 powierzchni płyty - w różnych położeniach względem płyty. Dla każdego z obciążeń określono najniekorzystniejsze położenia osłabienia podłoża. W tym artykule przedstawiono wyniki badania wrażliwości maksymalnych ugięć i maksymalnych naprężeń rozciągających na wielkość osłabienia podłoża w zdefiniowanych w pracy [3] najniekorzystniejszych położeniach. Analizowano jaki wpływ ma wielkość ubytku podłoża na rozważane wielkości. Przedstawiono plany warstwicowe maksymalnych naprężeń rozciągających w różnych wariantach zadania oraz wykresy zależności maksymalnych naprężeń i przemieszczeń w funkcji wielkości ubytku podłoża. Określono, przy jakich rozmiarach osłabienia podłoża może mieć ono istotny wpływ na wytrzymałość płyty. Przeprowadzone obliczenia wykonano z wykorzystaniem metody elementów skończonych, na bazie wcześniejszych doświadczeń modelowania.
In the previous paper of the authors [3] the analysis of some regular weakness of the foundation in the Werstergaard problem was discussed. Maximum displacements and maximum stresses were considered. The weakness was 1/9 of the plate area in various positions. The most dangerous situations were defined. The present paper is an extension of previous considerations for the analysis of sensitivity of the results for the size of weakness. The results are presented in the form of maximal stress maps (for qualitative analysis) as well as the tables and graphs (for quantitative analysis). The plate was modeled with the use of the finite element method.
Źródło:
TTS Technika Transportu Szynowego; 2013, 10; 1233-1242, CD
1232-3829
2543-5728
Pojawia się w:
TTS Technika Transportu Szynowego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Multivariate façade strengthening systems of textured layers in large slab panel buildings
Autorzy:
Tomaszewicz, Dariusz
Budrevich, Neli
Powiązania:
https://bibliotekanauki.pl/articles/1819322.pdf
Data publikacji:
2021
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
façade
bonded anchor
textured layer
diagnostic test
large slab panel buildings
fasada
kotew wklejana
warstwa teksturowana
test diagnostyczny
płyta stropowa
budynek
Opis:
This article presents the solutions of bonded anchors used to strengthen façade textured layers in the walls of three-layer large slab panel buildings in Poland. Large slab panel building systems that are found in Poland have been characterized. The use of new bonded anchors is preceded by diagnostics of the walls of three-layer large slab panel buildings. The author presents two-stage diagnostics: non-destructive methods, measurement of reinforcement parameters and its condition using a Profometer type device, and destructive methods by performing an opencast with a drilling rig. A review of previously used bonded anchorages in Poland was carried out. Proposals for the use of anchor groups in various configurations with different angles of inclination of the diagonal anchors were also presented in order to achieve the most durable effect possible.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2021, 3; 21--36
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametryczna ocena trwałości wielkopłytowej warstwy fakturowej po zastosowaniu zakotwień wklejanych w świetle badań eksperymentalnych
Parametric evaluation of the durability of a large slab textured layer after application of anchors bonded in the light of experimental research
Autorzy:
Tomaszewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/111023.pdf
Data publikacji:
2017
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
trwałość
ściana trójwarstwowa
warstwa fakturowa
budynki wielkopłytowe
badania eksperymentalne
durability
three-layer wall
texture layer
buildings of large slab
experimental research
Opis:
Z uwagi na zagrożenie odspojeniem warstwy fakturowej w budynkach wielkopłytowych, podejmowane są działania mające na celu zapobieganie temu zjawisku. Stopień zniszczenia oprocz jakości wykonania i oddziaływania czynnikow zewnętrznych, zależy przede wszystkim od lokalizacji obiektu (np. tereny gornicze). Na trwałość mocowania warstwy fakturowej mają wpływ: parametry żywicy (wytrzymałość na ściskanie, zginanie, rozciąganie oraz odporność termiczna), klasa betonu (stopień jego degradacji w konstrukcji) oraz gatunek i jakość stali (zwykła lub nierdzewna). W artykule zostaną przedstawione poprzez plan eksperymentalny parametry określające trwałość elewacyjnej warstwy fakturowej.
With attention to the disconnection threat of the textured layer in the buildings of large slab, actions are taken to prevent this phenomenon. The degree of destruction apart from the quality of performance and the influence of external factors depends primarily on the location of the facility (e.g. mining areas). The stability of fixing of the texture layer is influenced by: the characteristics of the resin (compressive strength, bending, stretching, and heat resistance),concrete class (the degree of degradation of the structure) and the species and quality of the steel (ordinary or stainless steel). In the article will be presented trough the experimental plan parameters determining the durability of the texture layer facade.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2017, 3-4; 25-29
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uwagi o obliczaniu szerokości rys w węzłach stropów zespolonych stalowo - betonowych
Comments concerning crack width calculation in joints of steel-concrete composite slabs
Autorzy:
Knauff, M.
Niedośpiał, M
Powiązania:
https://bibliotekanauki.pl/articles/390554.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
strop zespolony
konstrukcja zespolona
węzeł podatny
zarysowanie
steel-concrete composite slab
steel-concrete composite structure
semi-rigid joint
cracking
tension stiffening
Opis:
W artykule przedstawiono wybrane zagadnienia dotyczące zarysowania rozciąganej płyty żelbetowej w węzłach stropów zespolonych stalowo – betonowych. Według normy projektowania konstrukcji zespolonych [1] do obliczania szerokości rys wykorzystuje się zasady normy konstrukcji żelbetowych [2]. Z zaczerpniętego z [2] wzoru, w którym wzięto pod uwagę zjawisko „tension stiffening”, według [1] otrzymuje się zaskakująco duże naprężenia w zbrojeniu płyty, zwłaszcza dla niewielkiego stopnia zbrojenia. W związku z tym w artykule zamieszczono i skomentowano wyprowadzenie tego zaskakującego wzoru – rozpatrzono także przypadek nie uwzględniony w normie. W [1] nie rozróżnia się zjawisk zachodzących w bezpośrednim sąsiedztwie słupa od zjawisk zachodzących w pewnym oddaleniu od słupa. W związku z tym, proponuje się stosowanie w analizach, podobnie jak w [2], obszarów typu D (D od słowa „discontinuity”) w bezpośrednim sąsiedztwie węzła oraz obszarów typu B (od Bernoulli) w pewnym oddaleniu od węzła. Wywody teoretyczne rozpatrzono na tle wyników badań eksperymentalnych.
In this paper some aspects of the calculation of the width of cracks in joints of steel-concrete composite slabs are reported. The code concerning design of composite steel and concrete structures for the calculation of crack widths refers to the code of reinforced concrete structures. The application of the formula, which takes into account „tension stiffening”, seems to lead to surprising results - for the elements with small reinforcement ratio, the obtained stress is much greater than the stress calculated in classical way i.e. without tension stiffening. The authors present the derivation of this formula - the result corresponds to the formula in the code but in the paper an additional case is taken into account. Furthermore, the authors suggest to consider two types of areas as in the RC code. Type D (D from "discontinuity") should be analyzed in the close surrounding of the column and type B (B from Bernoulli) areas at some distance from the column.
Źródło:
Budownictwo i Architektura; 2014, 13, 3; 111-118
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza technologiczna i ekonomiczna wykonania stropów w budynku wpisanym do rejestru zabytków
Technological and economic analysis of the execution of ceilings in a building entered into the register of monuments
Autorzy:
Grzyl, Jakub
Grzyl, Beata
Powiązania:
https://bibliotekanauki.pl/articles/161288.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
budynek zabytkowy
Gdańsk
strop
renowacja
strop Kleina
strop zespolony
płyta żelbetowa
historic building
ceiling
renovation
Klein ceiling
composite ceiling
reinforced concrete slab
Opis:
W artykule przedstawia się analizę wybranych rozwiązań technologicznych dotyczących wymiany i wzmocnienia stropów w ramach inwestycji: Przebudowa, rozbudowa i rewaloryzacja zabytkowego budynku zlokalizowanego przy ul. Lastadia 2 w Gdańsku. Analizie poddaje się trzy alternatywne rozwiązania – wykonanie nowego stropu Kleina, nowej płyty żelbetowej oraz kompleksowe wzmocnienie istniejącego stropu. Wskazuje się zalety i wady każdego z proponowanych rozwiązań technologicznych oraz porównuje się je w aspekcie pracochłonności i kosztu. W podsumowaniu przedstawia się wnioski płynące z przeprowadzonej analizy.
The article presents the analysis of three chosen methods of constructing and reinforcing ceiling structures as a part of: Reconstruction, expansion and revaluation of historic building at Lastadia 2 street in Gdańsk. The three analysed solutions are: new steel-ceramic ceiling, new monolith reinforced concrete ceiling and general reinforcement of existing steel-ceramic ceiling. Conducted technological analysis shows advantages, disadvantages, labour effort and costs of the proposed solutions. The last part of this article summarises and concludes the analysis.
Źródło:
Przegląd Budowlany; 2019, 90, 4; 21-27
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the tie reinforcement on the development of a collapse caused by the failure of an edge column in RC flat slab system
Wpływ zbrojenia wieńcowego na rozwój katastrofy spowodowanej awarią słupa krawędziowego w ustroju płytowo - słupowym
Autorzy:
Buda-Ożóg, Lidia
Zięba, Joanna
Sieńkowska, Katarzyna
Nykiel, Damian
Powiązania:
https://bibliotekanauki.pl/articles/2203446.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
zbrojenie
zbrojenie wieńcowe
katastrofa postępująca
słup krawędziowy
strop słupowo-płytowy
odkształcenie
reinforcement
tie reinforcement
progressive failure
edge column
slab-column floor
deformation
Opis:
RC flat slabs are one of the most popular and effective methods of shaping plates in buildings. Although failures of entire structures are relatively rare, they cannot be excluded from the occupancy cycle of the facility. The research analysis presented in this paper is an attempt to understand more precisely the phenomena that occur in the RC flat slab system and to assess the influence of the additional protection of the flat slabs against progressive collapse in the case of failure of one of the supports. The results were obtained from destructive experimental investigations of a flat reinforced concrete slab made in scale 1:3. The collapse in the analysed model was simulated by removing three edge columns and additional loading by means of hydraulic actuator. In place of the columns removed, differential tie reinforcement was applied. The results obtained confirm that the structure achieved a much higher ultimate load than the one resulting from the design calculations.
Układy słupowo - płytowe są jedną z najbardziej popularnych i efektywnych metod kształtowania płyt w budynkach. Mimo że awarie całych konstrukcji zdarzają się stosunkowo rzadko, nie można ich wykluczyć z cyklu użytkowania obiektu. Przedstawione w niniejszej pracy analizy badawcze są próbą dokładniejszego zrozumienia zjawisk zachodzących w układzie płaskich płyt żelbetowych oraz oceny wpływu zastosowanego dodatkowego zbrojenia płyt przed postępującym zawaleniem w przypadku zniszczenia jednej z podpór. Wyniki uzyskano na podstawie niszczących badań doświadczalnych stropu żelbetowego wykonanego w skali 1:3. W analizowanym modelu symulowano zawalenie się stropu poprzez usunięcie trzech słupów krawędziowych i dodatkowe obciążenie siłownikiem hydraulicznym. W miejsce usuniętych słupów zastosowano zróżnicowane zbrojenie cięgnowe. Uzyskane wyniki potwierdzają, że konstrukcja osiągnęła znacznie większe obciążenie granicznie nośne niż to, które wynikało z obliczeń projektowych.
Źródło:
Archives of Civil Engineering; 2023, 69, 1; 39--54
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza przyczyn uszkodzenia stropu
Autorzy:
Jakubczyk, M.
Trochimiak, I.
Szydłowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/129255.pdf
Data publikacji:
2017
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
strop betonowy
płyta betonowa
skurcz betonu
spękanie betonu
rysa
analiza przyczyn
concrete floor
concrete slab
concrete shrinkage
concrete cracking
crack
causes analysis
Opis:
Analysis ol the cause of damage of a reinforced concrete floor above a garage of a multi-storey residential building. Undertaking an accurate assessment of the effects of concrete shrinkage and required minimum shrinkage reinforcement of complex reinforced concrete constructions emphasizes the fact of being an exceedingly difficult issue to consider. The analysis below broaches this matter basing on the example of a fragment of a building characterized by a rare construction system. Since the shrinkage aspects have not been taken into account, the applied reinforcement concerns only bending. Indeed, this fact, as well as the peculiarity of a shape of the building, affected the ceiling surface causing the emergence of a crack across its length and thus, plenty of leaks. The study of the above-mentioned case attempts to specify the quantity of required reinforcement by comparing results obtained from various methods adopted for this purpose.
Źródło:
Builder; 2017, 21, 8; 88-90
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of SFRC layer on deflections and cracks of composite RC slab
Wpływ warstwy fibrobetonu na ugięcia i rysy w płytach zespolonych
Autorzy:
Sadowska-Buraczewska, B.
Powiązania:
https://bibliotekanauki.pl/articles/231248.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ugięcie
rysa
fibrobeton
włókno stalowe
płyta zespolona
nośność
badanie doświadczalne
deflection
crack
fiber reinforced concrete
steel fiber
composite slab
carrying capacity
experimental study
Opis:
This paper presents an experimental analysis of flexural capacity and deformability of structural concrete slabs prepared as composite members consisting of two concrete layers made of reinforced ordinary concrete (N) and fiber reinforced concrete (SFRC). The reinforced concrete composite slabs used in the tests were prepared in the dimensions of 600 x 1200 x 80 mm. The basis was composed of two layers consisting of SFRC, one as the top layer, and one as ordinary concrete. The results of the analysis confirm a significant improvement of structural properties of the composite slab in comparison to the slabs prepared wholly of ordinary concrete.
Fibrobeton jest materiałem znanym, o czym świadczyć mogą liczne prace naukowe. W licznych artykułach [1,2] i publikacjach zawarto informacje o fizykomechanicznych właściwościach fibrobetonu [3,4]. Autorka proponuje użycie fibrobetonu z włóknami stalowymi, jako warstwy wzmacniającej lub naprawczej w płytowych elementach zespolonych. W publikacji zamieszczono badania krótkotrwałe płyt zespolonych w zakresie ugięć, rys i nośności w porównaniu z płytami kontrolnymi wykonanymi w całości z betonu zwykłego. Do wykonania elementów wykorzystano odpowiedni fibrobeton, który spełnia narzucone przez autorkę parametry (wytrzymałość betonu na ściskanie ok. 150MPa.). Celem przedstawionych w niniejszej pracy badań eksperymentalnych i analizy wyników jest oszacowanie wpływu warstwy fibrobetonu, zastosowanego w ściskanej górnej strefie elementu na całej długości, na ugięcia, nośność i rysy zespolonych płyt typu beton-beton w porównaniu z płytami kontrolnymi wykonanymi w całości z betonu zwykłego. W badaniach wykorzystano żelbetowe zespolone płyty o wymiarach 600 x 1200 x 80 mm. Płyta zespolona wykonana z dwóch warstw: fibrobetonu na górze i betonu zwykłego na dole. Analiza wyników badań potwierdza znaczącą poprawę właściwości konstrukcji zespolonej w porównaniu z płytami wykonanymi z betonu zwykłego. Na Rys. 1 przedstawiono schemat obciążenia i przekrój płyt zespolonych i kontrolnych.
Źródło:
Archives of Civil Engineering; 2016, 62, 3; 177-188
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polimerobetonowe płyty ustojowe dla napowietrznych linii, jako nowe rozwiązania techniczne
Polymer concrete standing plates for overhead lines as new technical solutions
Autorzy:
Juraszek, Janusz
Irauth, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1860955.pdf
Data publikacji:
2021
Wydawca:
Centrum Usług i Projektów Janusz Juraszek
Tematy:
polimerobetonowa płyta ustojowa
energetyczne linie napowietrzne
teletechniczne linie napowietrzne
masa
cena
polymer concrete floor slab
teletechnical overhead lines
power overhead lines
price
weight
Opis:
W artykule przedstawiono opis polimerobetonowych płyt ustojowych do zastosowania przy budowie energetycznych i teletechnicznych linii napowietrznych. Zwrócono uwagę na ich istotną cechę, jaką jest ich masa, oraz na ich wpływ na końcową cenę budowli.
This paper presents a description of polymer concrete ground slabs for use in the construction of power and teletechnical overhead lines. Attention has been drawn to their important feature, which is their weight, and to their influence on the final price of the structure.
Źródło:
Era Energii; 2021, 1; 14-15
2658-0195
Pojawia się w:
Era Energii
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szacowanie ryzyka zarysowania płyt fundamentowych według wytycznych niemieckich – komentarz
Commentary to scratching risk assessment for foundation slabs according to German guidelines
Autorzy:
Jaromska, Ewa
Zych, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/163481.pdf
Data publikacji:
2019
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
płyta fundamentowa
płyta denna
szacowanie ryzyka
zarysowanie
nieszczelność
minimalizacja ryzyka
wytyczne
komentarz
foundation slab
bottom
risk estimation
scratch
leak
risk minimization
guidelines
comment
Opis:
Jednym z podstawowych warunków użytkowalności w przypadku płyt fundamentowych jest zapewnienie ich wodoszczelności ze względu na możliwe okresowe lub stałe parcie wody gruntowej. W artykule przedstawiono, skomentowano oraz podano przykład zastosowania metody oceny ryzyka zarysowania zdefiniowanej w wytycznych Weiße Wannen. Metoda ta polega na doborze stabelaryzowanych wartości liczbowych odpowiadających poszczególnym założeniom projektowym, co w kolejnym kroku poprzez ważony wskaźnik pozwala ocenić stopień ryzyka wystąpienia nieszczelności w płytach fundamentowych.
One of the basic service conditions in the case of foundation slabs is to ensure their water-tightness due to the possible periodic or constant pressure of groundwater. Therefore, the article presents, comments on and gives an example of the application of a method of crack risk assessment as defined in the Weiße Wannen guidelines. This method is based on the selection of tabulated numerical values corresponding to individual design assumptions, which in the next step, through the weighted indicator, allows to assess the degree of risk of leakage for foundation slabs.
Źródło:
Przegląd Budowlany; 2019, 90, 9; 15-18
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental and theoretical study of the reinforced concrete flat slabs with the central support loss
Autorzy:
Tur, Viktar
Tur, Andrei
Lizahub, Aliaksandr
Powiązania:
https://bibliotekanauki.pl/articles/2172407.pdf
Data publikacji:
2022
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
flat slab
robustness
resistance mechanism
membrane action
dynamic resistance
energy balance method
płaska płyta
krzepkość
mechanizm oporowy
działanie membranowe
opór dynamiczny
metoda bilansu energetycznego
Opis:
The paper experimentally and theoretically considers the issues of assessing the robustness and resistance to progressive collapse of a flat slab with a sudden removal of the central support. The results of testing two scale models of a fragment of a flat ceiling in the case of removal of the central support under static (specimen FS-1) and dynamic (specimen FS-2) loading are presented and analyzed. A theoretical approach to the quantitative assessment of robustness was tested, which is based on the provisions of the energy balance of a damaged structural system in an accidental design situation.
Źródło:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych; 2022, 4; 12--41
2450-1859
2450-8721
Pojawia się w:
Inżynieria Bezpieczeństwa Obiektów Antropogenicznych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagadnienie Westergaarda - weryfikacja i modelowanie metodą elementów skończonych
Westergaard problem - verification and finite element modeling
Autorzy:
Gilewski, W.
Nagorski, R.
Sitek, M.
Powiązania:
https://bibliotekanauki.pl/articles/40309.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
plyty betonowe
podloza sprezyste
zagadnienie Westergaarda
przemieszczenia
naprezenia
modelowanie
metoda elementow skonczonych
concrete slab
elastic foundation
Westergaard problem
dislocation
stress
modelling
finite element method
Źródło:
Acta Scientiarum Polonorum. Architectura; 2011, 10, 3
1644-0633
Pojawia się w:
Acta Scientiarum Polonorum. Architectura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komentarz do zasad obliczania płyt na przebicie w strefie słupów narożnych według Eurokodu 2
Commentary to principles of eurocode 2 concerning punching shear of flat slabs within corner columns
Autorzy:
Gołdyn, M.
Urban, T.
Powiązania:
https://bibliotekanauki.pl/articles/104759.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
przebicie
płyta
słup
słup narożny
Eurokod 2
moment niezrównoważony
naprężenie styczne
punching shear
column
slab structures
corner column
Eurocode 2
unbalanced moment
shear stresses
Opis:
W artykule omówiono zasady obliczania na przebicie płyt w strefie słupów narożnych. Omówiono cztery metody określania naprężeń stycznych, wynikających z działania momentu niezrównoważonego, przekazywanego z płyty na słup. Przedstawiono przykład liczbowy ilustrujący różnice w rozkładzie naprężeń stycznych na długości obwodu kontrolnego w zależności od zastosowanej procedury obliczeniowej. Dokonano porównania wyników obliczeń z rezultatami badań eksperymentalnych. Pokazano, iż w większości przypadków stosowanie zasad Eurokodu 2 prowadzi do wyników po stronie bezpiecznej, aczkolwiek rzeczywiste nośności zostały w wielu przypadkach znacznie niedoszacowane – w szczególności dotyczyło to obliczeń metodą ogólną. Najlepszą zgodność, przy zarazem satysfakcjonującym poziomie bezpieczeństwa obliczeń, uzyskano w przypadku zastosowania metody zredukowanych obwodów kontrolnych. Na podstawie przeprowadzonych analiz zalecono ponadto ograniczenie wartości współczynnika k, uwzględniającego udział mechanizmu przebicia w przekazywaniu momentu niezrównoważonego z płyty na słup.
The paper presents the provisions for punching shear within corner columns. Four methods of determining of shear stresses, resulting from acting of unbalanced moment, were discussed. An example showing the differences in shear stress distribution on the control perimeter, depending on the design method, was presented. Experimental and theoretical results were also presented and discussed. It has been shown that in most cases the application of the principles of Eurocode 2 leads to results on the safe side although very conservative. The best agreement with experimental results was obtained by applying the method of reduced control perimeters.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 3/I; 235-245
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Potencjał betonu sprężonego
The usage of prestressed concrete in the project of the music pavilon in Muszyna
Autorzy:
Łabuzek, Barbara
Szydłowski, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/128835.pdf
Data publikacji:
2019
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
beton sprężony
pawilon muzyczny
belka sprężona
płyta sprężona
cięgno bez przyczepności
post-tensioned concrete
music pavilon
post-tensioned beam
post-tensioned slab
unbonded tendon
Opis:
W artykule przedstawiono przypadek ciekawego wykorzystania kablobetonu z cięgnami bez przyczepności w konstrukcji Pawilonu Muzycznego w Muszynie. Opracowane rozwiązania konstrukcyjne, a w szczególności zaprojektowane elementy sprężone – belka i strop – pozwoliły na zrealizowanie przyjętej koncepcji architektonicznej kładącej nacisk na zachowanie jedności konstrukcji z istniejącym otoczeniem.
The work presents a description of the proposed solutions, assumptions along with the reults of static and strength analysis and relevant applications. The design of The Music Pavilion in Muszyna is an example of the innovative application of construction elements made in the cable-concrete technology.
Źródło:
Builder; 2019, 23, 8; 8, 10-11
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Belka czy płyta? Klasyfikacja elementów konstrukcyjnych w świetle teorii wytrzymałości materiałów oraz literatury inżynierskiej
A beam or a slab? Classification of structural members according to the theory of solid mechanics and engineering literature
Autorzy:
Samborski, M.
Słowik, M.
Powiązania:
https://bibliotekanauki.pl/articles/390053.pdf
Data publikacji:
2017
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
slab
beam
definition of a bar-type member
definition of a shell-type
member
stress distribution
belka
płyta
definicja pręta
definicja powłoki
rozkład naprężeń
Opis:
Podstawą kategoryzacji belek i płyt w konstrukcjach żelbetowych są elementy prętowe i powłokowe zdefiniowane w ramach teorii wytrzymałości materiałów. Niejednoznaczność definicji belki i płyty, podawanych w literaturze inżynierskiej, może prowadzić do nieprawidłowego określenia rozkładu naprężeń w elementach żelbetowych.
The basic solid mechanics definition of a bar-type member and a shell-type member gives rules for the classification of structural reinforced concrete members on beams and slabs. But the definition of a beam and a slab, which we can find in an engineering literature, are not precise and this fact can lead to the incorrect determining of stress distribution in reinforced concrete members.
Źródło:
Budownictwo i Architektura; 2017, 16, 3; 103-112
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elementy Pikado dla hali widowiskowej w Toruńskich Jordankach wyprodukowanych w zakładzie Baumat
Pikado elements for the entertainment hall in Jordanki (Toruń), manufactured by the Baumat company
Autorzy:
Złotowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/163033.pdf
Data publikacji:
2015
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
hala widowiskowa
okładzina ścienna
płyta betonowa
elewacja ceramiczno-betonowa
element Pikado
technologia wytwarzania
entertainment hall
wall cladding
concrete slab
ceramic-concrete facade
Pikado element
production technology
Opis:
Autorka opisuje zastosowanie elementów Pikado przy budowie wielofunkcyjnej hali widowiskowej w Toruniu. Konkurs wygrała pracowania projektowa Fernando Menisa. Projektuje ona nowoczesne budynki z zastosowaniem betonu, ale bardzo silnie odwołujące się do geologicznych bogactw ziemi. Główny wykonawca poszukiwał wytwórcy prefabrykatów, który byłby w stanie wykonać trudne elementy – Pikado. Podjęła się tego Firma Baumat
The author describes the use of Pikado elements in the construction of a multi-purpose entertainment hall in Toruń. Fernando Menis (Menis Architectos) company was the one, who won the tender procedure. Menis’s company designs modern concrete buildings that are inspired by the geological resources of the Earth. The main contractor was looking for a manufacturer of the pre-fabricated elements, who would be able to execute the production process related to complicated Pikado elements. The task was undertaken by the Baumat company.
Źródło:
Przegląd Budowlany; 2015, R. 86, nr 9, 9; 53-55
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies