Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "skin dose" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
The effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
Autorzy:
Grabowicz, Włodzimierz
Masiarek, Konrad
Górnik, Tomasz
Grycewicz, Tomasz
Brodecki, Marcin
Dabin, Jérémie
Huet, Christelle
Vanhavere, Filip
Domienik-Andrzejewska, Joanna K.
Powiązania:
https://bibliotekanauki.pl/articles/2152963.pdf
Data publikacji:
2022
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
radiation protection
interventional cardiology
skin dose
lead free cap
brain dose
interventional physicians
Opis:
Objectives The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap can lead to ambiguous results, a detailed study was performed. Material and Methods The effectiveness of a lead free cap in reducing the doses to the skin was assessed in clinic by performing measurements with thermoluminescent dosimeters attached inside and outside the cap first during individual coronary angiography (CA) or CA/percutaneous transluminal coronary angioplasty (CA/PTCA) procedures and then cumulated during few procedures of the same type. In order to investigate the effect of the cap on reducing the doses to the brain additional measurements were performed with a male Alderson Rando and polymethyl methacrylate (PMMA) phantoms representing the physician and the patient, respectively for different projections. The brain dose per procedure, annual and cumulated during entire working practice were estimated for both cases working with and without the cap. Results The dose reduction factor (RF) for the skin (the quotient of doses outside and inside the cap) vary from 1.1 up to 4.0 in clinical conditions; on average 2.3-fold reduction is observed in the most exposed left temple. The RFs determined for the part of the head covered by the cap range from 1.4 to 1.8 while for the brain from 1.0 to 1.1 depending on the projection. The estimated annual brain dose for interventional cardiologist performing yearly 550 CA/PTCA procedures without any protective shields is 7.2 mGy and it is reduced with the lead free cap by an average factor of 1.1. Conclusions The study results proved the considerable effectiveness of lead free cap to protect the skin but very limited to protect the brain.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 5; 549-560
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of entrance skin dose and effective dose from abdomen radiography in two diagnostic facilities in Aba, Abia State, South-East Nigeria
Autorzy:
Esu, E. O.
Chiegwu, H. U.
Omojola, A. D.
Eze, E. M.
Powiązania:
https://bibliotekanauki.pl/articles/1839405.pdf
Data publikacji:
2021
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Entrance skin dose (ESD)
Local diagnostic reference levels (LDRLs)
Dose area product (DAP)
Effective dose (E)
Absorbed dose (DT)
Thermoluminescent dosimeter (TLD)
Kilovoltage peak (kVp)
milliampere-seconds (mAs)
Opis:
Medical exposure for abdomen radiography is associated with higher doses compared to X-Rays of the chest and other extremities. The study aims to determine the mean entrance skin dose (ESD) for 104 adult patients between 20-89 years with 2 X-Ray units (A and B) in Aba, South-East Nigeria and to determine the ESD at the 75th percentile to estimate the local diagnostic reference levels (LDRLs). This study also determined the effective dose (E), the dose area product (DAP) and the relationship between absorbed dose (DT) and other parameters. This study will also compare its findings with relevant articles where necessary. The study used 2 functional floors mounted X-Ray units. A total of 208 annealed thermoluminescent dosimeters (TLDs) were used made of Lithium Fluoride, doped with Magnesium and Titanium (LiF: Mg, Ti). Two TLD chips were used per patient. The chips were positioned at the anterior and posterior end of the patient respectively for a given beam area for abdomen radiography. After exposure, a calibrated RadPro TLDcube 400 reader (Freiberg Instrument, Germany) was used to estimate individual patient doses. This was done by multiplying the TLD counts by a pre-determined calibration factor (CF). The mean/75th percentile ESD for facilities A and B was 2.92/4.12 and 3.01/3.67 mGy. The E for facilities A and B was 0.73 and 0.82 mSv respectively. There was a good relationship between the DT with ESD, exit dose (ED) and DAP for facility A, but no relationship was seen with other parameters. The mean ESD was lower compared to the National Council on Radiation Protection and Measurements (NCRP 172) and the American Association of Physicists in Medicine (AAPM) reports respectively. The study proved useful and could serve as a reference point to initiate LDRLs within the South-East zone in Nigeria for abdomen radiography.
Źródło:
World Scientific News; 2021, 161; 143-156
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies