Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "single-phase inverter" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
Adjusting output impedance using a PI controller to improve the stability of a single-phase inverter under weak grid
Autorzy:
Jiao, J.
Nelms, R. M.
Powiązania:
https://bibliotekanauki.pl/articles/136224.pdf
Data publikacji:
2016
Wydawca:
EEEIC International Barbara Leonowicz Szabłowska
Tematy:
grid impedance
inverter output impedance
LC filter
PI controller
single-phase inverter
Opis:
Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.
Źródło:
Transactions on Environment and Electrical Engineering; 2016, 1, 4; 50-57
2450-5730
Pojawia się w:
Transactions on Environment and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model of a single-phase inverter’s with voltage regulation
Autorzy:
Zaskalicky, P.
Zaskalicka, M.
Powiązania:
https://bibliotekanauki.pl/articles/2056350.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
model matematyczny
przekształtnik
regulacja napięcia
mathematical model
single-phase inverter
voltage regulation
Opis:
The paper deals with mathematical model of single-phase bridge inverters which outputs voltage is controlled by a pulse-width notching. The transistors in the inverter circuit are turned on and off so as to produce zero periods of equal length, for unipolar modulation, or negative voltage for bipolar modulation. The D.C. source is being a fixed level of voltage. Suppose the notching frequency to be constant for all frequency of the fundamental squarewaves and to be fixed on 500 Hz. The output inverter’s voltage is expressed by an analytical formula based on Fourier complex series. On the base of output voltage, the waveforms of the output currents are analytically calculated for different inverter’s loads.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2009, 83; 41-45
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Train based on virtual synchronous generator technology uninterrupted phase-separation passing study
Autorzy:
Wang, Ying
Yang, Huan
Chen, Xiaoqiang
Guo, Ya
Powiązania:
https://bibliotekanauki.pl/articles/27309940.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
energy storage railway power conditioner
single-phase inverter
uninterrupted
phase-separation passing
virtual synchronous generator
Opis:
The problem of large speed loss exists in the traditional passing through the electric phase-separation method of trains, which is more prominent when trains pass through an electric phase-separation zone in the uphill section of long ramps and may lead to the trains not passing through the phase-separation zone safely. In order to solve this problem, based on the energy storage type railroad power conditioner, a train uninterrupted phase-separation passing system based on the energy storage type railroad power conditioner is proposed. The energy storage railroad power conditioner can realize the recovery and utilization of regenerative braking energy of the electrified railroad. In the structure of the energy storage railroad power conditioner, the single-phase inverter is led from the middle DC side of the energy storage railroad power conditioner and connected to the neutral line through the LCL filter and the step-up transformer, which constitutes an uninterrupted phase separation passing system. The single-phase inverter is controlled using virtual synchronous generator technology, which allows the single-phase inverter to have external characteristics similar to those of a synchronous generator, providing support for the voltage and frequency in the neutral zone. The power required by the train to pass the electric phase-separation is provided by the power supply arm or the energy storage system, which not only improves the utilization rate of regenerative braking energy but also realizes the uninterrupted phase separation passing of the train through the control of the voltage in the neutral region.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 755--768
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency comparison between the LLCL and LCL-filters based single-phase grid-tied inverters
Autorzy:
Wu, W.
Huang, M.
Blaabjerg, F.
Powiązania:
https://bibliotekanauki.pl/articles/140537.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCL filter
LLCL-filter
efficiency power loss
modulation
single-phase grid-tied inverter
Opis:
An LLCL-filter is becoming more attractive than an LCL-filter as the interface between the grid-tied inverter and the grid due to possibility of reducing the copper and the magnetic materials. The efficiency of the LLCL-filter based single-phase grid-tied inverter also excites interests for many applications. The operation of the switches of the VSI is various with different modulation methods, which lead to different efficiencies for such a single-phase grid-tied inverter system, and therefore important research has been carried out on the effect of the choice of PWM schemes. Then power losses and efficiencies of the LLCL-filter and the LCL-filter based single-phase grid-tied inverters are analyzed and compared under the discontinuous unipolar, the dual-buck and the bipolar modulations. Results show that the efficiency of LLCL-filter based inverter system is higher than the LCL- filter based independent on the modulation method adopted. Experiments on a 2 kW prototype are in good agreement with results of the theoretical analysis.
Źródło:
Archives of Electrical Engineering; 2014, 63, 1; 63-79
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jednofazowy falownik napięcia z aktywnym obwodem odsprzęgającym
Single-phase inverter with active power decoupling
Autorzy:
Czyż, P.
Cichowski, A.
Śleszyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/267988.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
falownik jednofazowy
odsprzęganie składowej przemiennej mocy chwilowej
sterowanie przekształtnikiem
tranzystor z węglika krzemu
SiC
single-phase inverter
decoupling of the alternating component of the instantaneous power
converter control
silicon carbide transistors
Opis:
Znanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy. W pracy przedstawiono ideę aktywnego odsprzęgania mocy na przykładzie układu podwyższającego napięcie. Następnie zaprezentowano sposób doboru elementów obwodu odprzęgającego oraz przyjętą strategię sterowania. Zaproponowany model zweryfikowano w programie symulacyjnym oraz zaimplementowano w zbudowanym modelu laboratoryjnym falownika. W badaniach laboratoryjnych osiągnięto znaczną redukcję składowej prądu wejściowego o częstotliwości dwukrotnie większej od częstotliwości podstawowej falownika oraz sprawność powyżej 94%.
In single-phase inverters the instantaneous output power contains a DC component and a double line frequency power oscillation. To cope with the issue of inducing a significant current and voltage ripples on the DC side, the most popular approach is to decouple DC and AC sides with a bulky bank of electrolytic capacitors. This method is however reducing the reliability, life-time and power density of a converter. Most recently active power decoupling methods are gaining popularity as an alternative approach to solve this issue. In this paper a film capacitor based active power decoupling method in a boost topology is presented. First of all, the methods of DC active power decoupling, the principle of decoupling in a boost topology and selection of decoupling circuit elements are given. Then, the proposed control strategy is described and verified by the simulation. Finally, a constructed prototype of the single-phase inverter is presented and measurements at 500 W output power are conducted. The obtained results proves the feasibility of the identified approach and also high power efficiency of 94% is achieved.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 57; 17-20
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of mechanical and electromagnetic phenomena on electric motor vibrations in different power supply options
Autorzy:
Wróbel, Mateusz
Barczewski, Roman
Jakubek, Bartosz
Rukat, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/2146620.pdf
Data publikacji:
2020
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
electric motor
vibration
supply
star
single-phase
inverter
multi-synchronous averaging
silnik elektryczny
drgania
zasilanie
gwiazda
zasilanie jednofazowe
falownik
uśrednianie multisynchroniczne
Opis:
Results of research about influence of mechanical and electromagnetic phenomena on electric motor vibration in different supply options has been shown in this paper. Three different supply options have been taken under consideration: typical star connection, single-phase connection with work capacitor and connection through an inverter. Vibration signals recorded on electric motor end shield and frame has been digitally processed using Multi-Synchronous Averaging (MSA). This technique allowed to decompose total vibration signal into signals associated with mechanical and electromagnetic phenomena occurring in electric motor. The comparison of rms values and spectra shapes of total and decomposed vibration signals has been made. Energy shares of previously mentioned phenomena in vibration signal for different supply options has been also estimated.
Źródło:
Vibrations in Physical Systems; 2020, 31, 1; art. no. 2020102
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies