Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sieve" wg kryterium: Temat


Tytuł:
Analysis of sieve holes blocking in a vibrating screen and a rotary and drum screen
Autorzy:
Lawinska, K.
Modrzewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/110206.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sieve
screen blocking
screening machine
Opis:
Main objective of screening is to separate a group of grains, which dimensions fall within the specified limits, from the given feed. A large number of sieve and screening machines designs is available. During screening of granular materials in industry, sieve holes are often blocked. The phenomenon of screen blocking involves grains of varying sizes and geometries being clogged in sieve holes. This significantly decreases the screening efficiency. The mechanism of sieve holes blocking is largely random. A dry and contamination-free granular material with 0.1-2.5 mm size was screened in this study. The grains with spherical (agalite and chromium stainless shot), sharp-edged (aggregate) and irregular (quartz sand) were used in screen tests under various conditions. Screening tests included both intermittent, as well as continuous screening. Identification on blocking of sieve holes was conducted using vibrating devices and a rotary and drum screen with a cone-shaped sieve. This paper specifies the main operational parameters of these machines that had remarkable influence on the blocking of sieve holes.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 2; 812-828
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A movable string sieve - analysis of seed screening
Autorzy:
Kaliniewicz, Z.
Domański, J.
Powiązania:
https://bibliotekanauki.pl/articles/298132.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
string sieve
modeling
physical properties
Opis:
The conditions of seed movement in a string sieve set into reciprocating motion have been formulated for cereal, vetch, pea, lupine and faba bean seeds. In the analyzed string sieve, seed movement was determined by a combination of the following parameters: angular velocity of the crank, crank radius, seed size, seed’s coefficient of external friction, string diameter and angle of inclination of the separator screen. A string sieve for cleaning and sorting most farm-produced seeds was analyzed. The width of the separating groove was set at 1 mm at the beginning of the screen and 11 mm at the end of the screen, and the strings had the diameter of 4 mm. Our results indicate that seeds cannot be effectively graded in the modeled string sieve. The angular velocity of the crank exceeds the velocity which is applied to power conventional separator buckets, and it could damage the separator. A reduction in the angular velocity of the crank to the recommended level caused seeds to become jammed directly before the screening site. The above problem can be solved by propelling seeds into motion with the use of special sweeping brushes.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2013, 16(4); 253-264
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność przesiewu ziarna przy różnym kształcie i rozmieszczeniu żaluzji sita
Effectivity of grain screening at various shape and configuration of the sieve shutters
Autorzy:
Bieniek, J.
Banasiak, J.
Olszewska, A.
Powiązania:
https://bibliotekanauki.pl/articles/287658.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
sito żaluzjowe
geometria sita
kombajn zbożowy
przesiewanie
shutter sieve
sieve geometry
combine harvester
screening
Opis:
W niniejszej publikacji przedstawiono wyniki badań przesiewalności czterech modeli fragmentów sit: dwa z języczkami krótkimi, dwa z długimi, o różnym ustawieniu względem siebie. Badania przeprowadzono dla nachylenia płaszczyzny głównej sita α = 10° i β =10°. Skuteczność przesiewu w modelach sięgała 99,0%.
Four models of sieve parts were tested. Two of these models were with short and two with long wings of different arrangement towards each other. The research for shutter sieves was done for inclination angles α=10° and β =10°. The efficiency of separating was 99%.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 3, 3; 79-85
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Segregacja odpadów mineralnych na przesiewaczu dwuczęściowym
Segregation of mineral waste on a double-frequency screen
Autorzy:
Modrzewski, R.
Wodziński, P.
Powiązania:
https://bibliotekanauki.pl/articles/2070947.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przesiewacz
przesiewanie
sito
screen
screening
sieve
Opis:
Niniejsza praca przedstawia wyniki programu badawczego dotyczącego przesiewacza dwuczęstościowego. Do jego napędu zastosowano dwa wibratory rotacyjne o jednakowych lub różnych momentach statycznych. Jak sama nazwa wskazuje jest to przesiewacz, który charakteryzuje się dwiema różnymi częstościami obrotowymi tych wibratorów napędowych. Na podstawie wyników badań opracowano założenia projektowe maszyny przemysłowej przeznaczonej do przesiewania odpadów mineralnych.
The present study demonstrates the research programme results concerning a double-frequency screen. Two rotational vibrators of the same or different static moments are applied for the screen drive. As the name indicates, it is a screen which is characterized by two different frequency of drive vibrators. On the basis of research results the design assumptions of industrial machine aimed at mineral waste screening were elaborated.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 2; 83-84
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ruch drgający rzeszota przesiewacza dwuczęstościowego
Oscillating motion of a double-frequency screen
Autorzy:
Modrzewski, R.
Wodziński, P.
Powiązania:
https://bibliotekanauki.pl/articles/349470.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
przesiewacze
przesiewanie
sito
screens
screening
sieve
Opis:
Niniejsza praca prezentuje wyniki programu badawczego prowadzonego w Katedrze Aparatury Procesowej Politechniki Łódzkiej, a poświęconego przesiewaczom dwuczęstościowym. Badania te miały na celu określenie kinematyki przesiewacza doświadczalnego w skali półtechnicznej. Na podstawie zaprezentowanych wyników badań zostaną opracowane założenia projektowe maszyny przemysłowej przeznaczonej do przesiewania drobno ziarnowego.
The present study demonstrates the results of the research programme carried out at the Department of Process Equipment, Technical University of Lodz, and concerns double-frequency screens. It is widely known that the shape of trajectory in the oscillating motion of the screen has a relevant meaning for obtaining of the best processing properties of the machine. Therefore, the trajectories of oscillating motion, which will lead to the intensive segregation of the grain layer moving on the sieve, have been searched for a long time. Seemingly, it is possible to obtain a double-frequency screen. Two rotational vibrators of the same or different static moments are applied for the drive of such a screen. As the name indicates, it is a screen which is characterised by two different rotational speeds of those drive vibrators. Presented investigations were aimed at the determination of the experimental screen kinematics on a semi-technical scale. On the basis of the research results the design assumptions of the industrial machine aimed at fine-grained screening have been elaborated.
Źródło:
Górnictwo i Geoinżynieria; 2010, 34, 4/1; 193-202
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przesiewacze wieloczęstościowe. Studium rozwoju
Multi-frequency screens. Development case study
Autorzy:
Modrzewski, R.
Wodziński, P.
Powiązania:
https://bibliotekanauki.pl/articles/2070529.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przesiewacz
przesiewanie
sito
screen
screening
sieve
Opis:
Niniejsza praca przedstawia różne warianty konstrukcyjne przesiewaczy wiełoczęstościowych, które mogą znałeźć zastosowanie różnych gałęziach gospodarki narodowej. Są to przesiewacze, które charakteryzują się co najmniej dwiema różnymi prędkościami obrotowymi wibratorów rotacyjnych napędzających te maszyny.
The paper presents constructional variants of multifrequency screens used in diHerent branches of national industry. These screens are characterized at least by two rotary speeds of vibrators driving these machines.
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 4; 85-86
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie przesiewaczy dwuczęstościowych w przemyśle spożywczym
Application of double-frequency screens in food industry
Autorzy:
Modrzewski, R.
Wodziński, P.
Powiązania:
https://bibliotekanauki.pl/articles/2071641.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przesiewacz
przesiewanie
sito
screen
screening
sieve
Opis:
Niniejsza praca prezentuje wyniki programu badawczego prowadzonego w Katedrze Aparatury Procesowej Politechniki Łódzkiej, a poświęconego przesiewaczom dwuczęstościowym. Do napędu tego przesiewacza zastosowane są dwa wibratory rotacyjne o jednakowych lub niejednakowych momentach statycznych. Jak sama nazwa wskazuje jest to przesiewacz, który charakteryzuje się dwiema różnymi prędkościami obrotowymi tych wibratorów napędowych.
The results of research programme carried out at the Department of Process Equipment, Technical University of Łódź, concerning double-frequency screens are presented in the paper. Two rotational vibrators of the same or different static moments were applied for driving the screen. The screen was characterised by two different rotational speeds of both drive vibrators.
Źródło:
Inżynieria i Aparatura Chemiczna; 2011, 1; 27-28
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of the effectiveness of selected medical segregation systems - START, SIEVE, CAREFLIGHT
Porównanie efektywności wybranych systemów segregacji medycznej – START, SIEVE, CAREFLIGHT
Autorzy:
Klepacka, Monika
Bakalarski, Paweł
Gajek Villebæk, Pamela Antonella
Leszczyński, Piotr Konrad
Powiązania:
https://bibliotekanauki.pl/articles/1033017.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Pomocy Doraźnej
Tematy:
CAREFLIGHT
Medical segregation
SIEVE
START
triage
Opis:
INTRODUCTION: In the face of sudden events with many victims, various types of medical segregation systems were created. Their aim is to set the treatment and transport priority of patients by giving them appropriate urgency codes considering their general condition and vital parameters. The study is aimed at comparing the effectiveness of selected medical segregation systems. MATERIAL AND METHODS: The research tool consisted of one hundred virtual patients, whose condition was categorized according to the START system (Simple Triage and Rapid Treatment) for four urgency codes - 25 persons for each of four categories. Then they were segregated by assigning the wounded to individual urgency codes using the SIEVE and CAREFLIGHT systems. To the statistical analysis was used the Mann-Whitney U test. All results were considered significant at p <0.05. RESULTS: Among 100 patients using the SIEVE system, 25 were identified in green and black code, 27 in yellow code and 23 in red code. Using the CAREFLIGHT system, 25 patients were shown in green and black code, 31 in yellow code and 19 in red code. There were no differences between segregation systems between green and black code patients (Code 3 and 4: START = 25 vs. SIEVE = 25 vs. CAREFLIGHT = 25). In contrast, the yellow code showed differences in the SIEVE system compared to the control group - START system (p = 0.005, Code 2: START = 25 vs. SIEVE = 18), which, however, was not demonstrated in relation to CAREFLIGHT (Code 2: START = 25 vs. CAREFLIGHT = 25). In the red code showed differences between the control group and the SIEVE system (p = 0.001, Code 1: START = 25 vs SIEVE = 16), and the CAREFLIGHT system (p = 0.010, Code 1: START = 25 vs. CAREFLIGHT = 19). CONCLUSIONS: The effectiveness of selected medical segregation systems (START, SIEVE and CAREFLIGHT) is significantly different among patients in yellow and red code. Taking into account the highest urgency code, the most sensitive selection is shown by the START system, and the least sensitive - CAREFLIGHT.
WSTĘP: W obliczu występowania nagłych zdarzeń z wieloma poszkodowanymi, powstały różnego typu systemy segregacji medycznej. Ich celem jest ustalanie priorytetu leczniczo-transportowego pacjentów poprzez nadanie im odpowiednich kodów pilności biorąc pod uwagę ich stan ogólny oraz parametry życiowe. Przeprowadzone badanie ma na celu porównanie efektywności wybranych systemów segregacji medycznej. MATERIAŁ I METODY: Narzędzie badawcze stanowiło stu wirtualnych pacjentów, których stan został skategoryzowany według systemu START (Simple Triage and Rapid Treatment) na cztery kody pilności -po 25 osób do każdej z czterech kategorii. Następnie poddano ich segregacji przyporządkowując rannych do poszczególnych kodów pilności stosując systemy: SIEVE oraz CAREFLIGHT. Do analizy statystycznej posłużono się testem U Manna-Whitney’a. Wyniki uznano za istotne przy p < 0,05. WYNIKI: Wśród 100 pacjentów przy zastosowaniu systemu SIEVE wyodrębniono po 25 w kodzie zielonym oraz czarnym, 27 w kodzie żółtym oraz 23 w kodzie czerwonym. Korzystając z systemu CAREFLIGHT wykazano po 25 pacjentów w kodzie zielonym i czarnym, 31 w kodzie żółtym oraz 19 w kodzie czerwonym. Między pacjentami w kodzie zielonym i czarnym nie wykazano różnic pomiędzy systemami segregacji (Kod 3 i 4: START = 25 vs. SIEVE = 25 vs. CAREFLIGHT = 25). Natomiast w kodzie żółtym wykazano różnice systemu SIEVE w stosunku do grupy kontrolnej – systemu START (p=0,005; Kod 2: START = 25 vs. SIEVE = 18), której jednak nie wykazano w stosunku do CAREFLIGHT (Kod 2: START = 25 vs. CAREFLIGHT = 25). W kodzie czerwonym wykazano różnice pomiędzy grupą kontrolną oraz systemem SIEVE (p=0,001; Kod 1: START = 25 vs SIEVE = 16), a także systemem CAREFLIGHT (p=0,010; Kod 1: START = 25 vs. CAREFLIGHT = 19). WNIOSKI: Efektywność wybranych systemów segregacji medycznej (START, SIEVE oraz CAREFLIGHT) jest istotnie zróżnicowana wśród pacjentów w kodzie żółtym i czerwonym. Uwzględniając najwyższy kod pilności, najbardziej czułą selekcję wykazuje system START, a najmniej czułą - CAREFLIGHT.
Źródło:
Critical Care Innovations; 2019, 2, 1; 1-10
2545-2533
Pojawia się w:
Critical Care Innovations
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
K primeneniju metod mekhaniki splosnykh sred dlja opisanija dvizhenija zernovykh smesejj na vibroreshetakh
To the application methods of continuum mechanics to describe the motion of grain mixes on vibrating sieves
Autorzy:
Tishhenko, L.
Kharchenko, S.
Powiązania:
https://bibliotekanauki.pl/articles/78243.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
grain mixture
sieve
vibration
separation
dynamics model
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2013, 15, 7
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
String sieve: design concept and parameters
Autorzy:
Kaliniewicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/298037.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
seed
cleaning
sorting
geometric parameters
string sieve
Opis:
This paper presents the design concept and the parameters of a new device for cleaning and-or sorting seeds and grain produced in a conventional farm. The discussed device is a string sieve where the groove between adjacent strings is minimal at the beginning of the screen and increases towards the end of the screen. The proposed sieve poses an alternative to a screen separator comprising a set of differently-sized mesh screens with longitudinal openings. In view of the average size of farm-produced seeds, the width of the separating groove should be set at 1mm at the beginning of the screen and 11 mm at the end of the screen. In sieves not designed for grading large seeds or vetch seeds, the width of the separating groove can be set at 1 mm and 5 mm, respectively.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2013, 16(2); 119-129
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On the consistency of sieve bootstrap prediction intervals for stationary time series
Autorzy:
Różański, Roman
Zagdański, Adam
Powiązania:
https://bibliotekanauki.pl/articles/729798.pdf
Data publikacji:
2004
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
prediction intervals
sieve bootstrap
method of sieves
Opis:
In the article, we consider construction of prediction intervals for stationary time series using Bühlmann's [8], [9] sieve bootstrapapproach. Basic theoretical properties concerning consistency are proved. We extend the results obtained earlier by Stine [21], Masarotto and Grigoletto [13] for an autoregressive time series of finite order to the rich class of linear and invertible stationary models. Finite sample performance of the constructed intervals is investigated by computer simulations.
Źródło:
Discussiones Mathematicae Probability and Statistics; 2004, 24, 1; 5-40
1509-9423
Pojawia się w:
Discussiones Mathematicae Probability and Statistics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Theoretical Analysis of Cereal Seed Screening in a String Sieve
Autorzy:
Kaliniewicz, Z.
Powiązania:
https://bibliotekanauki.pl/articles/298351.pdf
Data publikacji:
2013
Wydawca:
Uniwersytet Warmińsko-Mazurski w Olsztynie
Tematy:
string sieve
modelling
seeds
angle of inclination
Opis:
The conditions of the screening process in a fixed string sieve designed by the author have been formulated. The string sieve was designed for separating seeds of 5 cereal species (wheat, rye, barley, oats and triticale). The width of the separating groove was set at 1 mm at the beginning of the screen and 5 mm at the end of the screen. It has been assumed that seeds have a spheroidal shape and that their motion is initiated by positioning the string sieve at an appropriate angle. The results of a theoretical analysis revealed that at the given parameters of a string sieve, the above angle is determined only by the thickness and width of separated seeds. The sieve’s angle of inclination should be set at 45° to propel seeds into motion and at 50° to ensure the continuity of the screening process. Such a large setting angle is not recommended because it increases the sieve’s height and deteriorates the quality of the separation process. The problem can be solved by setting the separator bucket into motion and separating seeds at a small inclination angle of the string sieve.
Źródło:
Technical Sciences / University of Warmia and Mazury in Olsztyn; 2013, 16(3); 234-247
1505-4675
2083-4527
Pojawia się w:
Technical Sciences / University of Warmia and Mazury in Olsztyn
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of screening process of crushed basalt performed by a double-frequency screen
Autorzy:
Modrzewski, R.
Wodzinski, P.
Powiązania:
https://bibliotekanauki.pl/articles/109707.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
screening
screen
sieve
grained material
double-frequency screen
Opis:
This work presents the results of the investigations, devoted to multi-frequency screens, devic-es being used for the screening process and equipped with two drive vibrators operating at various rota-tion speeds. The object of this research was to evaluate the efficiency and capacity of a newly designed double-frequency screen to sieve the grained materials, especially those difficult to separate. The experi-mental double-frequency screen is driven by two inertial drive vibrators operating at various rotation speed, providing complex shaking movement of the screen. In comparison to conventional devices con-taining vibrators operating at constant rotation speed, the application of this modern double-frequency screen resulted in improving parameters of the screening process.
Źródło:
Physicochemical Problems of Mineral Processing; 2013, 49, 1; 81-89
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ grubości sita i odległości od bijaków na skład granulometryczny śruty pszennej
The impact of sieve thickness and distance from beaters on grain composition of ground wheat grain
Autorzy:
Kwiatkowski, S. P.
Powiązania:
https://bibliotekanauki.pl/articles/292069.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
rozdrabnianie
pszenica
sito
rozdrabniacz
shredding
wheat
sieve
shredder
Opis:
W pracy przedstawiono proces rozdrabniania pszenicy ozimej o wilgotności 13,4% w zależności od grubości sita w rozdrabniaczu oraz różnej odległości bijaków od powierzchni sita. Badania przeprowadzono na rozdrabniaczu pionowym o trzech różnych grubościach sit tj.: 1,5 mm, 2 mm, 2,5 mm, otwory w sicie 2,8 mm. Dla każdej grubości sita ustawiano jednakowe odległości od bijaków, wynoszące: 12, 16 i 20 mm. Na wydajność procesu rozdrabniania duży wpływ ma odpowiednia odległość bijaków od sita, natomiast grubość sit w zakresie 1,5-2,5 mm nie ma istotnego wpływu na rozkład granulometryczny otrzymanej śruty pszennej.
The work presents shredding process for winter wheat with humidity of 13.4% depending on a thickness of sieve in a shredder and varying distance of beaters from sieve surface. The tests were carried out in a vertical shredder containing sieves with three different thickness values that is: 1.5 mm, 2 mm, 2.5 mm; sieve mesh - 2.8 mm. The same distances from beaters were set for each sieve thickness, that is: 12, 16 and 20 mm. Proper distance between beaters and sieve is a factor significantly affecting shredding process efficiency, whereas sieve thickness ranging within 1.5-2.5 mm has no considerable effect on grain composition of obtained ground wheat grain.
Źródło:
Inżynieria Rolnicza; 2011, R. 15, nr 4, 4; 177-182
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies