Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sewage sludge stabilization" wg kryterium: Temat


Tytuł:
Oczyszczanie odcieków z beztlenowej stabilizacji osadów z oczyszczalni ścieków mleczarskich przy zastosowaniem metody hydrofitowej
Treatment of Reject Water from Anaerobic Sewage Sludge Stabilization in Constructed Wetland
Autorzy:
Dąbrowski, W.
Wiater, J.
Boruszko, D.
Powiązania:
https://bibliotekanauki.pl/articles/1818578.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
odcieki
stabilizacja osadów ściekowych
złoża hydrofitowe
reject water
sewage sludge stabilization
constructed wetland
Opis:
The paper presents author's experience related to reject water treatment with constructed wetland (CW). CW technology is well known worldwide to treat municipal wastewater, rainwater and also industrial wastewater. The problem with reject water is mainly concerning high concentration of ammonia nitrogen. It is observed mainly in municipal WWTPs utilizing anaerobic sewage sludge stabilization. Dairy WWTP belonging to Mlekovita was modernized in 2013 with implementation of flotation process in wastewater line and anaerobic stabilization of excess and flotation sludge. Probably this is the biggest dairy WWTP in Poland. It is operating (July 2014) with 6886 m3/d and personal equivalent about 278 000 (project was done for PE 35 0000 and maximum flow 75000 m3/d). Reject water as a byproduct like sewage sludge is returned to the beginning of wastewater line. During own research with reject water it was found that concentration of ammonia nitrogen was varied from 291 N-NH4+/dm3to 423 mg N-NH4+/dm3. while value of BOD5 from 132 to 185 mg O2/dm3. Laboratory scale investigation was carried out with vertical flow CW model with total depth 0,65 m. filled with gravel and sand. Two hydraulic loads were applied during investigations – 0,1 and 0,2 m/d. The temperature during two series was changing from 22,0 do 26,0°C. High efficiency of BOD5 removal (up to 91%) from reject water produced in dairy WWTP was observed. The efficiency of ammonia nitrogen removal was varied from 78,3% to 90,0%. The efficiency of total phosphorus removal was low in both series. Vertical flow constructed wetland can be used as a low cost method to decrease load of dairy WWTP utilizing anaerobic sewage sludge utilization. To increase efficiency of reject water treatment lower hydraulic load (from 0,05 m/d) should be applied. Future researches will be carried out with real scale installation in Wysokie Mazowieckie equipped with special aeration system to supply vertical flow CW with oxygen.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 2; 869-879
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alternatywne metody wykorzystania pyłów z pieców wapienniczych i cementowych, ze szczególnym uwzględnieniem gospodarki osadowej
Alternative methods of cement and lime kiln dusts utilization, especially with sewage sludge pretreatment
Autorzy:
Bożym, M.
Powiązania:
https://bibliotekanauki.pl/articles/392205.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
cement
wapno
produkcja
wykorzystanie odpadów
stabilizacja osadów ściekowych
lime
manufacturing
waste utilization
sewage sludge stabilization
Opis:
Pyły z pieców cementowych (CKD) oraz pyły z pieców wapienniczych są odpadami powstającymi podczas produkcji cementu i wapna. Zebrane w odpylaczach pyły są zwykle składowane. Nie jest to jednak metoda preferowana z uwagi na negatywny wpływ na środowisko. Część pyłów trafia do powtórnego wykorzystania w piecach pod warunkiem, że nie zawierają składników mogących obniżyć jakość produktu. Z uwagi na wysoki udział tlenku wapnia, pyły mogą być wykorzystane także w ochronie środowiska, w tym do neutralizacji kwaśnych ścieków i odpadów, stabilizacji i nawożenia gleb czy do przetwarzania osadów ściekowych. W wielu krajach prowadzone są badania nad zagospodarowaniem coraz większej ilości pyłów powstających w przemyśle cementowym i wapienniczym. W pracy przedstawiono przegląd badań dotyczących możliwości wykorzystania pyłów z pieców cementowych i wapienniczych, ze szczególnym uwzględnieniem stabilizacji i higienizacji osadów ściekowych.
Cement kiln dust (CKD) and lime kiln dust are a wastes of cement and lime manufacturing. After collection in precipitators behind the kilns, the dusts are dumped on a waste heap. The disposal is not an environmentally favorable situation. The obvious use of those dusts are they re-incorporation in the production cycle. Sometimes this way is impossible to application for contaminated dusts. CKD and lime kiln dusts characterize high content of free lime. For this reason dusts could be use in environment to neutralization of acidic sludges or wastes, soil stabilization, fertilization or sewage sludge treatment. Research to overcome cement and lime dusts development is being carried out in different countries to find appropriate ways of using those wastes in various applications. This work presents a research review on CKD and lime kiln dust in various applications, esspecially in sewage sludge stabilization and higienization.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2011, R. 4, nr 8, 8; 59-68
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspekty kinetyki autotermicznej termofilnej stabilizacji osadów ściekowych – wykorzystanie równań różnych rzędów
Aspects of kinetics autothermal thermophilic aerobic digestion of sewage sludge – the use of equations of various orders
Autorzy:
Filkiewicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/401183.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
kinetyka
osad ściekowy
stabilizacja osadów ściekowych
kinetics
sewage sludge
stabilization of sewage sludge
Opis:
Z ekonomicznego punktu widzenia, w procesie stabilizacji osadów ściekowych, istotne jest poznanie kinetyki rozkładu substancji organicznych i czasu przetrzymania osadów w komorze stabilizacji. Wiąże się to m.in. z kosztami inwestycyjnymi budowy instalacji, wydatkami związanymi z eksploatacją technologii, czy też areałem zajmowanej przestrzeni. Jedną z metod stabilizacji jest autotermiczna termofilowa stabilizacja osadów ściekowych (ATSO). Szybkość procesu ATSO można zobrazować poprzez badanie poszczególnych parametrów np.: suchej masy organicznej, czy też chemicznego zapotrzebowania na tlen. Założono, że proces ATSO przebiega zgodnie z prawem działania mas, co pozwala na matematyczne ujęcie stopnia przereagowania i szybkości reakcji. W ramach prowadzonej analizy uzyskane na obiekcie rzeczywistym wyniki badań odniesiono do równań szybkości różnych rzędów. Badania przeprowadzono na osadzie ściekowym pochodzącym z oczyszczalni ścieków w Olecku, w której to wprowadzono dwustopniowy proces autotermicznej tlenowej stabilizacji osadów ściekowych. Przeprowadzono analizę kinetyki procesu stabilizacji poprzez podstawienie zbadanych parametrów do równań obrazujących reakcje kolejnych rzędów i zastosowanie aproksymacji liniowej. Tym samym zbadano, które modele równań są najbliższe rzeczywistym wartościom. Co więcej, wykazano skuteczność procesu ATSO (np. poprzez wskazanie stabilizacji osadu). Prace związane z określeniem kinetyki procesu mają na celu m. in utworzenie modelu opisującego szybkość procesu, w tym uzyskanie odpowiedzi czy ww. równania mogą być podstawą do dalszych prac związanych z określeniem czynników wpływających na proces stabilizacji.
From an economic point of view, in the process of stabilization of sewage sludge it is important to know the kinetics of decomposition of organic matter and sediment retention time in the stability chamber. This involves, among other things, the investment costs of building installations, expenses related to the operation of technologies or the acreage of the occupied space. One method of stabilization is autothermal thermophilic aerobic digestion (ATAD). The speed of the process of ATAD can be illustrated by examining the individual parameters such as: dry organic matter or chemical demand for oxygen. It was assumed that the ATAD process proceeds in accordance with the law of mass action, which allows for mathematical recognition of completeness of reaction and reaction rate. As a part of its analysis the results obtained on the real object have been referred to the rate equations of various orders. The study was conducted on the sewage sludge derived from a sewage treatment plant in Olecko, where two-step process autothermal aerobic of sewage sludge digestion were introduced. The analysis of the kinetics of stabilization process by substitution of the investigated parameters to the equations illustrating the reactions of consecutive orders, and application of linear approximation. Thus, it has been studied which model of equations are the closest to real values. Moreover, the efficacy of the ATAD process was demonstrated (e.g., by indicating the sludge stabilization). The work to identify the kinetics of the process are aimed at, among others, creating a model describing the speed of the process, including obtaining an answer whether the above equations can be the basis for further work on identifying the factors influencing the stabilization process.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 132-138
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Drop in Conductivity of Sewage Sludge in the Process of Autothermal Thermophilic Aerobic Digestion
Autorzy:
Bartkowska, I.
Powiązania:
https://bibliotekanauki.pl/articles/123193.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal stabilization of sewage sludge
conductivity of sewage sludge
neutralization of sewage sludge
sanitation of sewage sludge
sewage sludge processing
Opis:
The article presents research on the assessment of electrolytic conductivity changes of sludge during the process of its autothermal thermophilic aerobic digestion (ATAD), which takes place in a two-stage installation system, operating in a municipal sewage-treatment plant. In the years 2012–2014 sludge was studied and the results were analyzed. Thickened sludge in the intermediate tank, which was then directed to installation reactors, was examined. Conductivity was measured in each tank. In this manner collected results made it possible to follow the changes of this index at consecutive stages of the system. The results were statistically analyzed and it was determined to what degree, as a result of an objective process, the values of processed sludge conductivity would change. The conclusions from the carried-out studies and from own experiments are also presented.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 67-75
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Aerobic Stabilization of Sewage Sludge on PAHs Concentration in Reject Waters
Autorzy:
Kozak, Jolanta
Włodarczyk-Makuła, Maria
Popenda, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1839628.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
PAHs
municipal sewage sludge
coking sewage sludge
reject water
aerobic stabilization
Opis:
In the paper, the results of studies on changes in the concentration of selected polycyclic aromatic hydrocarbons (PAHs) in the reject water coming from aerobic stabilization of sewage sludge process were given. The sewage sludge samples originating from a treatment of municipal wastewater treatment plant and an industrial coking wastewater treatment plant were investigated. A technological study was conducted using a municipal sewage sludge (control sample) and a mixture of municipal and industrial sewage sludge simultaneously. Aerobic stabilization of sewage sludge process was carried out for 21 days. The concentration of PAHs was determined at the beginning of the experiment (day 0) and in seven-day intervals: after 7, 14 and 21 days. The initial concentration of PAHs in the reject water coming from the municipal sewage sludge was over 44 g/dm3. Industrial sewage sludge was heavily loaded with polycyclic aromatic hydrocarbons. In a reject water of the mixture of municipal and industrial sludge, the initial content of PAHs reached over 5200 g/dm3. During aerobic stabilization of sewage sludge, a decrease in PAHs concentration in reject water was observed. After 21 days of the experiment, the decrease of the sum of analyzed PAHs was in the range of 62–98%.
Źródło:
Journal of Ecological Engineering; 2021, 22, 4; 27-35
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Selected Technical and Technological Parameters of the Sewage Sludge Stability Process
Autorzy:
Bartkowska, I.
Wawrentowicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/123847.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
autothermal thermophilic stabilization
sewage sludge
dry mass
organic substances
sewage sludge hygienization
sewage sludge in agriculture
Opis:
The article presents the results of the analysis, which was carried out in 2015-2017 on the example of autothermal installation of thermophilic sludge stabilization (ATAD) in a sewage treatment plant in Giżycko. The installation was created in 2003 as the first of its kind and still remains operational. The purpose of the conducted research was to assess the suitability of the analyzed technological parameters as tools that can be used by operators to determine the actual possibilities of changing the operating conditions of the installation or to develop an optimization strategy to reduce the energy demand. The dry mass content and organic dry mass content was used as the assessment indicators. In the analysed period, the sludge from the process contained from 47.47% to 60.80% of organic matter in the dry mass of the sludge. The organic dry matter decrease due to the process was also calculated, and it ranged from 26.4% to 48.7%. The amount of sludge undergoing the process and the amount of electricity consumption were also analysed. On this basis, the energy consumption indicators in the ATAD process were calculated.
Źródło:
Journal of Ecological Engineering; 2018, 19, 4; 69-74
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stabilizacja tlenowa osadów komunalnych i przemysłowych
Oxygen stabilization of municipal and industrial sewage sludges
Autorzy:
Popenda, Agnieszka
Kozak, Jolanta
Włodarczyk-Makuła, Maria
Powiązania:
https://bibliotekanauki.pl/articles/126565.pdf
Data publikacji:
2019
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
osady ściekowe
stabilizacja tlenowa
osady komunalne
osad przemysłowy
sewage sludges
aerobic stabilization
municipal sewage sludge
industrial sewage sludge
Opis:
Stabilizacja tlenowa jest jednym ze sposobów przeróbki osadów ściekowych powstających w procesie oczyszczania ścieków. Celem procesu jest utlenianie związków biodegradowalnych oraz polepszenie właściwości osadów poprzez zmniejszenie uwodnienia, a także w pewnym stopniu higienizacja osadów przed ich dalszym zagospodarowaniem. Osady ściekowe z komunalnych oczyszczalni ścieków, do których dopływa mieszanina ścieków bytowych i przemysłowych, charakteryzują się wysokim uwodnieniem, dużą zawartością łatwo rozkładalnych substancji organicznych, organizmów chorobotwórczych, a także zróżnicowaną ilością antropogennych związków trudno rozkładalnych. Natomiast osady ściekowe pochodzące z oczyszczalni przemysłowych zawierają mniej składników organicznych biodegradowalnych, co sprawia, że trudniej zagniwają, lecz zwykle lepiej się odwadniają. Ponadto zawierają, w zależności od rodzaju przemysłu, domieszki substancji specyficznych, często toksycznych dla biocenozy biorącej udział w biologicznym oczyszczaniu. Celem badań było przeanalizowanie przebiegu procesu stabilizacji tlenowej mieszaniny osadu pochodzącego z komunalnej oczyszczalni ścieków oraz osadu wydzielonego ze ścieków koksowniczych. Osad komunalny pobrano z oczyszczalni miejskiej o wielkości przekraczającej równoważną liczbę mieszkańców RLM 100 000, natomiast przemysłowy - z zakładowej biologicznej oczyszczalni ścieków. Stabilizację prowadzono w otwartych komorach tlenowych z ciągłym napowietrzaniem przez 21 dni. Przebieg procesu stabilizacji kontrolowano czterokrotnie (w odstępach 7 dniowych), analizując wybrane wskaźniki fizyczno-chemiczne, takie jak: pH, ChZT, kwasowość, zasadowość w cieczach nadosadowych oraz uwodnienie, suchą masę i straty przy prażeniu w osadach ściekowych.
Aerobic stabilization is one of an option of sewage sludges treatment. The aim of the stabilization process is to change physical-chemical parameters, mainly decomposition of biodegradable compounds, decrease of water content and partial hygienisation of sewage sludge before the further treatment. Municipal sewage sludges have high water content, high concentration of easily degradable organic compounds, pathogens and various amount of anthropogenic compounds persistent to degradation process. In contrast, industrial sewage sludges have lower concentration of easily degradable organic compounds resulting in more persistent digestion but they can be easily dewatered. Furth more, sludges, depending to the type of industry, contain additives of specific substances that are usually toxic for biocenosis taking part in biological treatment. The aim of the study was to analyze process of aerobic stabilization using mixture of sludge originating from a municipal wastewater treatment plant as well as sludge coming from a coke plant treatment. Municipal sewage sludge samples were taken from the treatment plant exceeding 100 000 equivalent number of inhabitants, whereas industrial sewage sludge comes from a biological industrial wastewater treatment. The stabilization process was carried out in opened chambers with continuous oxygenation over 21 days. The process of stabilization was controlled four times (in seven day intervals). The selected physical-chemical parameters such as: pH, chemical oxygen demand, acidity, alkalinity were analyzed in supernatants, whereas water contents, dry and organic matter content were determined in sewage sludges.
Źródło:
Proceedings of ECOpole; 2019, 13, 1-2; 145-154
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rola preparatu ECO TABS™ w stabilizacji osadów ściekowych Cz. II: Ocena właściwości mikrobiologicznych osadów
ECO TABS™ preparation action in stabilization of sewage sludge Part II: Assessment of microbiological properties of sludge
Autorzy:
Wolna-Maruwka, A.
Jakubus, M.
Jordanowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/126728.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
biopreparat
mikroorganizmy
osad ściekowy
stabilizacja
biopreparation
microorganisms
sewage sludge
stabilization
Opis:
Powstające w procesach oczyszczania ścieków osady poddawane są najczęściej stabilizacji w otwartych komorach fermentacyjnych w celu zmniejszenia ich podatności do zagniwania oraz zmniejszenia ilości organizmów chorobotwórczych. Zawartość składników organicznych w osadach ściekowych (ok. 80% s.m. w osadzie surowym) jest czynnikiem determinującym stosowanie biopreparatów w celu przyspieszenia procesu biodegradacji masy organicznej. Biopreparaty tworzy się na bazie odpowiednio dobranych szczepów rodzimych lub allochtonicznych drobnoustrojów. Poddaje się je starannej selekcji, a następnie wprowadza do danych warunków środowiskowych. Z uwagi na aspekty praktyczne biopreparaty komercyjne wykazują szereg zalet, przede wszystkim są łatwe w pozyskaniu, magazynowaniu, jak również w dozowaniu. W skład biopreparatów, których zadaniem jest optymalizacja rozkładu materii organicznej, należą bakterie rodzaju Pseudomonas oraz Bacillus. Ich cechą charakterystyczną jest niezwykłe bogactwo nietypowych szlaków metabolicznych, wysokie zdolności adaptacyjne do różnych warunków środowiskowych, wytwarzanie endospor w przypadku Bacillus sp., degradacja złożonych i często toksycznych substancji, w tym również fakultatywne przełączanie aparatu metabolicznego na warunki beztlenowe (w przypadku Pseudomonas sp.). Celem przeprowadzonych badań było monitorowanie zmian liczebności heterotroficznych bakterii właściwych i grzybów pleśniowych, jak również poziomu aktywności dehydrogenaz w osadzie ściekowych po zastosowaniu biopreparatów ECO TABSTM POND TABLETS oraz ECO TABSTM ECO GRANULAR SHOCK. Obiektem badań były dwie frakcje osadu ściekowego pobieranego z otwartej komory fermentacyjnej, znajdującej się na terenie mechaniczno-biologicznej oczyszczalni ścieków komunalnych we Wrześni. Do komory fermentacyjnej w okresie od 27 kwietnia do 25 czerwca 2014 roku (codziennie) aplikowano 15 sztuk ECO TABSTM POND TABLETS i 15 sztuk ECO TABSTM ECO GRANULAR SHOCK firmy ECO TABS™ Europe. Już na początku eksperymentu zaobserwowano rozdział całej mieszaniny na 2 frakcje: cięższą opadającą na dół zbiornika i lżejszą unoszącą się w jego górnej części. W związku z tym do analiz mikrobiologicznych i biochemicznych pobierano próbki z obu frakcji jednocześnie, co 12-14 dni w kolejnych, sześciu terminach i po 25 dniach w ostatnim terminie badań (termin I - 27 kwietnia 2014, II - 5 maja, III - 22 maja, IV - 4 czerwca, V - 16 czerwca, VI - 30 czerwca, VII - 25 lipca 2014). Analizy mikrobiologiczne przeprowadzono z zastosowaniem metody płytkowej Kocha i polegały na oznaczeniu ogólnej liczebności bakterii heterotroficznych i grzybów pleśniowych. Osad ściekowy poddano również analizie biochemicznej, która polegała na określeniu metodą spektrofotometryczną poziomu aktywności dehydrogenaz. Na podstawie uzyskanych wyników badań stwierdzono, że zaaplikowanie biopreparatów ECO TABSTM POND TABLETS oraz ECO TABS TM ECO GRANULAR SHOCK przyczyniło się do istotnie statystycznego wzrostu ogólnej liczby heterotroficznych bakterii właściwych, grzybów pleśniowych, jak również poziomu aktywności dehydrogenaz w osadzie, pochodzącym zarówno z dolnej, jak i górnej części komory fermentacyjnej. Najsilniejsze namnażanie się mikroorganizmów oraz najwyższą ich aktywność odnotowano w ostatnich, trzech terminach analiz. Ponadto wykazano, że wyższą liczebnością oraz aktywnością analizowanych drobnoustrojów charakteryzowała się dolna frakcja osadu ściekowego.
Sludge produced in sewage treatment processes is usually stabilized in open fermentation chambers in order to reduce its rotting tendency and to reduce the amount of pathogenic organisms. The content of organic components in sewage sludge (about 80% of dry weight in raw sludge) is a factor that determines the use of biopreparations to accelerate the process of organic mass degradation. Biopreparations are based on appropriately selected native or allochthonous microorganisms. They are carefully selected to match the environmental conditions. Due to practical aspects commercial biopreparations exhibit a wide range of advantages - above all, they can be easily acquired, stored and dosed. Pseudomonas and Bacillus are the bacterial genera used as components in biopreparations. They are responsible for optimisation of decomposition of organic matter. They are characterised by unique richness of atypical metabolic pathways, high adaptability to different environmental conditions, formation of endospores (Bacillus sp.), degradation of complex and usually toxic substances and facultative switching of the metabolic apparatus to anaerobic conditions (Pseudomonas sp.). The aim of the study was to monitor variation in the population of heterotrophic eubacteria and moulds and to monitor dehydrogenases activity in sewage sludge after the application of ECO TABSTM POND TABLETS and ECO TABSTM ECO GRANULAR SHOCK biopreparations. The research objects were two fractions of sewage sludge collected from an open fermentation chamber located in a biomechanical sewage treatment plant in Września, Poland. From 27 April to 25 June 2014 15 pieces of ECO TABSTM POND TABLETS and 15 pieces of ECO TABSTM ECO GRANULAR SHOCK (ECO TABS™ Europe) were applied daily to the fermentation chamber. As early as the beginning of the experiment we observed that the mixture had split into two fractions: a heavier fraction, which dropped to the bottom of the container and a lighter fraction, which floated in the upper part of the container. In view of this fact, samples for microbiological and biochemical analyses were collected from both fractions simultaneously, every 12-14 days at six consecutive terms and after 25 days at the last term of the research (term I - 27 April 2014, II - 5 May, III - 22 May, IV - 4 June, V - 16 June, VI - 30 June, VII - 25 July 2014). The microbiological analyses consisted in applying Koch's plate technique to determine the total number of heterotrophic bacteria and moulds. The sewage sludge was also analysed biochemically, where spectrophotometry was applied to determine the level of dehydrogenases activity. The research findings revealed that the application of ECO TABS TM POND TABLETS and ECO TABS TM ECO GRANULAR SHOCK biopreparations caused a statistically significant increase in the total number of heterotrophic bacteria and moulds. The biopreparations also increased dehydrogenases activity in the sludge collected both from the upper and lower parts of the fermentation chamber. The greatest proliferation of microorganisms and their highest activity was observed at the last three terms of analyses. Apart from that, the lower fraction of the sewage sludge proved to have greater populations of the microorganisms under study and the microorganisms were more active.
Źródło:
Proceedings of ECOpole; 2016, 10, 1; 367-378
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilans ścieków, osadów i odcieków w zmodernizowanej oczyszczalni ścieków mleczarskich S.M. Mlekovita
Sewage, sludge and reject water balance in Mlekovita Dairy WWTP after modernization
Autorzy:
Dąbrowski, W.
Boruszko, D.
Kajurek, M
Powiązania:
https://bibliotekanauki.pl/articles/297063.pdf
Data publikacji:
2014
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ścieki mleczarskie
stabilizacja beztlenowa
odcieki
dairy sewage
sewage sludge
anaerobic stabilization
reject water
Opis:
W artykule przedstawiono problemy związane z modernizacją jednej z największych oczyszczalni ścieków mleczarskich w Polsce. Oczyszczalnia ścieków mleczarskich firmy S.M. Mlekovita w Wysokiem Mazowieckiem została poddana modernizacji, którą zakończono w 2013 roku. Projekt zakładał Równoważną Liczbę Mieszkańców (RLM) na poziomie 350 000 przy przepływie 7500 m3/d. W procesie oczyszczania ścieków stosuje się flotację ciśnieniową. Oczyszczanie biologiczne zachodzi w komorze defosfatacji oraz w dwóch komorach osadu czynnego z zastosowaniem symultanicznej nitryfikacji i denitryfikacji. Stosowane jest także chemiczne usuwanie fosforu. Osad nadmierny, poflotacyjny oraz serwatka są stabilizowane beztlenowo. W pracy przedstawiono badania przeprowadzone w maju 2014 roku, w których określono parametry ścieków dopływających do oczyszczalni oraz odcieków pochodzących z beztlenowej przeróbki osadu nadmiernego, poflotacyjnego oraz serwatki. Stwierdzono bardzo duże obciążenie oczyszczalni ładunkiem zanieczyszczeń zawartym w odciekach z przeróbki osadów, które odprowadzane są do części biologicznej oczyszczalni. Projekt modernizacji nie uwzględnił konieczności ich wydzielonego oczyszczania poza głównym ciągiem biologicznym. Według badań własnych średnia wartość BZT5 w ściekach mleczarskich wynosiła 2738,0 mg O2/dm3 , w przypadku odcieków było to 185,0 mg O2/dm3. Odwrotną tendencję zaobserwowano w przypadku azotu amonowego. Jego stężenie w ściekach mleczarskich wynosiło średnio 4,0 mg N-NH+4/dm3, natomiast w odciekach 340,0 mg N-NH+4/dm3. Uwzględniając ilość ścieków dopływających z mleczarni i miasta oraz ilość odcieków, stwierdzono, że ładunek azotu amonowego zawarty w odciekach jest ponad 3-krotnie wyższy od ładunku zawartego w ściekach mleczarskich i komunalnych. Otrzymane rezultaty potwierdziły celowość badań nad możliwością zastosowania metody hydrofitowej do wydzielonego oczyszczania odcieków w oczyszczalni w Wysokiem Mazowieckiem.
The article presents problems connected with modernization of one of the dairy waste water treatment plants (WWTP) in Poland. The dairy WWTP belonging to Mlekovita Dairy co-operative in Wysokie Mazowieckie is one of the major ones with Personal Equivalent (PE) about 350 000 and average daily flow of 7500 m3 (data for modernization project). In the sewage treatment, dissolved air flotation (DAF) process was implemented, which allowed significant decrease of pollution load discharged to biological treatment. Biological treatment is carried out in biological chambers allowing simultaneous nitrification and denitrification. Aerobic stabilization of sewage sludge in separate chambers was replaced by anaerobic system. Excess sludge, flotation sludge and whey were stabilized simultaneously in anaerobic reactor. Implementation of anaerobic system enabled production of heat and electric energy from biogas. During own research conducted in May 2014, basic parameters of raw dairy waste water, municipal waste water and reject water were determined. Values of BOD, COD and concentration of ammonia nitrogen, total nitrogen and phosphorus were examined in laboratory belonging to Mlekovita and Bialystok University of Technology (BUT). The modernization project did not include separate treatment of reject water before its discharging to biological treatment. During own research average value of BOD in dairy sewage was 2738 mg O2/dm3 and 185 mg O2/dm3 in reject water. In case of total phosphorus it was 44.0 mg P/dm3 in dairy sewage and 41.0 mg P/dm3 in reject water. Reverse tendency was observed in case of ammonia nitrogen concentration which was in average 4.0 mg N-NH+4/dm3.
Źródło:
Inżynieria i Ochrona Środowiska; 2014, 17, 3; 483-491
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research of Effective Microorganisms on Dairy Sewage Sludge Stabilization
Autorzy:
Boruszko, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/125371.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
dairy sewage sludge
vermiculture
Effective Microorganisms
stabilization
reed bed
energy-crop willow
Opis:
The present paper was aimed at determining the influence of particular methods and biological processes, including the application of Effective Microorganisms, on the change in characteristics of the treated dairy sewage sludge, especially when discussing the changes in the content of nutrients and macroelements. The purpose of the conducted research was to specify the possibility of using natural biological methods of dairy sewage sludge treatment and adapting it to environmental, especially farming use. Diagnostic research on the content of sewage sludge from dairy wastewater treatment plants in the north-eastern region of Poland has been conducted since the 1990s. On the basis of the results and the assessment of the possibility of agricultural utilization of dairy sewage sludge, the objectives for research on sludge treatment were established. The research facilities were located on the premises of Municipal Wastewater Treatment Plant in Zambrów. The choice of location for the research facilities was guided by the possibility of supplying the same sludge from dairy wastewater treatment. The excess sludge from biological dairy sewage treatment, which was aerobically stabilized in separate chambers, was used in the research. In all of the facilities where sludge was treated with biological methods, Effective Microorganisms (EM) were also used for comparison. In the years 2010-2013, the research was conducted in the research facilities (own project) constructed and launched in 2010, which were planted with phragmites and common osier. In the years 2010-2012, the research was conducted in the research facilities (own project) constructed and launched in 2010, i.e. vermiculture patches. The conducted research was comprehensive and the obtained experiment results point to the necessity of continuation and further development of research concerning the content transformation in dairy sewage sludge during its biological treatment. Establishing the role of microorganisms present in the EM formula on the processes and transformations occurring in biologically treated sewage seems to be of exceptional importance. The innovativeness of the research lay mainly in a very comprehensive range of natural biological methods of treatment applied for the same sewage sludge coming from dairy wastewater treatment plants. The conducted research points to the influence of the EM formula on vital changes in the content of macroelements in the biologically treated dairy sewage sludge. The most important impact (from the point of view of the number of parameters and the change in size as a result of applying EM formula) was observed in reference to the vermicomposting process with the use of earthworms and long-term stabilization in reed beds. The statistical assessment methods applied to the obtained results of own research (Wilcoxon and Spearman tests, Spearman’s rank correlation coefficient) point to a significant influence of the EM formula on different “behavior” of many analyzed characteristics of the treated sludge.
Źródło:
Journal of Ecological Engineering; 2019, 20, 3; 241-252
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Rheological Models of Modified Sewage Sludge
Analiza modeli reologicznych modyfikowanych osadów ściekowych
Autorzy:
Wolski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1813834.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady ściekowe
modele reologiczne
nadźwiękawianie
stabilizacja
sewage sludge
rheological models
sonication
stabilization
Opis:
This paper presents the results of examinations of sewage sludge from cellulose and paper industry. The aim of the study was to determine rheological models (the Ostwald-de Waele, Bingham and Herschel-Bulkley models) of non-conditioned sewage sludge and the sludge exposed to the effect of the ultrasound field at its different intensities and then stabilized in flasks and in the bioreactor. Evaluation of rheological properties of sewage sludge allows for a detailed characterization of their pumpability and abilities during the hydraulic transport. The examinations revealed the increase in the yield stress and consistency coefficient through application of the energy of the ultrasound field. The values of the parameters discussed were reduced on consecutive days of the stabilization process.
W artykule przedstawiono wyniki badań prowadzone na osadach ściekowych z przemysłu celulozowo-papierniczego. Celem prowadzonych badań było wyznaczenie modeli reologicznych (Ostwalda-de Waele, Binghama, Herschela-Bulkley’a) dla osadów ściekowych niekondycjonowanych oraz poddanych działaniu pola ultradźwiękowego przy różnych jego natężeniach, a następnie stabilizacji w kolbach i bioreaktorze. Poznanie właściwości reologicznych osadów umożliwia dokładną charakterystykę ich pompowalności oraz zdolności podczas transportu hydraulicznego. W wyniku przeprowadzonych badań stwierdzono zwiększenie granicy płynięcia, jak również konsystencji poprzez zastosowanie energii pola ultradźwiękowego. Wartości omawianych parametrów ulegały obniżenie podczas kolejnych dni prowadzenia procesy stabilizacji.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 230-239
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concentration of Hydrocarbons in Reject Waters During Aerobic Stabilization of Sewage Sludge
Stężenie WWA w cieczach nadosadowych w procesie stabilizacji tlenowej osadów ściekowych
Autorzy:
Włodarczyk-Makuła, Maria
Popenda, Agnieszka
Kozak, Jolanta
Powiązania:
https://bibliotekanauki.pl/articles/1812018.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
PAHs
reject water
municipal sewage sludge
coking sewage sludge
aerobic stabilization
WWA
ciecze nadosadowe
osady ściekowe komunalne
osady koksownicze
stabilizacja tlenowa
Opis:
The article presents the concentrations of selected polycyclic aromatic hydrocarbons (PAHs) in reject water during aerobic stabilization of sewage sludge process. The investigations were carried out in parallel for two samples i.e. for sewage sludge samples coming from a treatment of municipal wastewater treatment plant (control sample) and for mixture of municipal and industrial sludge. The aerobic stabilization process was carried out for 21 days. The concentration of 5-ring and 6-ring PAHs was determined at the beginning of the experiment (day 0) and in seven-day intervals: after 7, 14 and 21 days, respectively. The initial contents of PAHs was equal to 23 μg/L and 29.1 μg/L respectively in reject water from municipal and mixture sludge. During aerobic stabilization process the decrease in the concentration of studied PAHs in reject water was observed. At the end of carrying the aerobic stabilization process the decrease of the total concentration of PAHs achieved 78% in municipal reject water, whereas in coke reject water reached the value of 38%, respectively.
W artykule przedstawiono stężenia wybranych wielopierścieniowych węglowodorów aromatycznych WWA w cieczach nadosadowych w procesie stabilizacji tlenowej osadów ściekowych. Badania prowadzono z wykorzystaniem osadów powstających podczas oczyszczania ścieków komunalnych oraz ścieków koksowniczych. Badania technologiczne prowadzono równolegle dla dwóch próbek, tzn. osadów komunalnych (próbka kontrolna) oraz mieszaniny osadów komunalnych z przemysłowymi. Proces stabilizacji tlenowej był prowadzony przez 21 dób. Stężenie 5- oraz 6- pierścieniowych WWA oznaczano na początku badań, dwukrotnie podczas trwania procesu stabilizacji oraz po upływie 21 dób. Początkowe stężenie WWA wynosiło 23 μg/L i 29,1 μg/L odpowiednio w cieczach nadosadowych z osadów komunalnych i z osadów mieszanych. Podczas stabilizacji tlenowej osadów odnotowano spadek stężenia WWA w cieczach nadosadowych. Po zakończeniu procesu stabilizacji tlenowej osadów spadek sumarycznej ilości badanych WWA był na poziomie 78% w przypadku osadów komunalnych i 38% – w przypadku osadów mieszanych.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 2; 1318-1327
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wspomaganie końcowego zagęszczania i odwadniania osadów ściekowych
Support of the Final Thickening and Dewatering of Sludge
Autorzy:
Wolski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1815485.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
osady ściekowe
stabilizacja
kondycjonowanie chemiczne
nadźwiękawianie
odwadnianie
sewage sludge
stabilization
chemical conditioning
sonication
dehydration
Opis:
Odwadnianie to podstawowy proces zmniejszenia objętości osadów ściekowych. W celu zwiększenia zdolności osadów do oddawania wody stosuje się różne procesy wspomagające. Jedną z metod jest zastosowanie polielektrolitów, jak również działanie pola ultradźwiękowego przy odpowiednio dobranych parametrach sonifikacji. Kondycjonowanie osadów ściekowych zmienia strukturę oraz właściwości osadów, powodując zmiany w równowadze układu, co sprzyja zwiększeniu zdolności do zagęszczania i odwadniania. W artykule przedstawiono wyniki badań dotyczące zastosowania polielektrolitów kationowych Praestol, dezintegracji ultradźwiękowej oraz połączenia powyższych metod na przebieg procesu zagęszczania, jak również wartości czasu ssania kapilarnego i oporu właściwego osadów. W badaniach wykorzystano dwie długości fali pola ultradźwiękowego (39,42 µm oraz 21,4 µm) oraz czasy ekspozycji 15 i 30 s. Dla różnych kombinacji i połączeń założonych parametrów procesu kondycjonowania określano ich wpływ na przebieg zagęszczania, czas ssania kapilarnego (CSK) oraz wartości oporów. Przy założonych parametrach prowadzenia badań zaobserwowano dla wszystkich kombinacji kondycjonowania poprawę zagęszczania osadów ściekowych w odniesieniu do osadów niekondycjonowanych. Również dla niektórych metod wspomagania odnotowano uzyskanie wyników charakteryzujących lepszą efektywność oddawania wody.
The article presents results of research on the use of cationic polyelectrolyte Praestol, ultrasonic disintegration, and a combination of these methods on the process of compaction as well as the capillary suction time and the resistiveity of the sludge. The study used two wavelengths of the ultrasound field (39.42 microns and 21.4 microns) and exposure times of 15 and 30 s. For various combinations and connections established parameters of the conditioning process determined their impact on the thickening time of capillary suction (CST), and resistance values. The assumed parameters of research was observed for all combinations of improving the conditioning of sludge thickening for nonprepared sludge. Also, for some methods of supporting observed to obtain results more efficiently characterize the donation of water.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 1; 730-742
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dewaterability of thermal conditioned sewage sludge after anaerobic stabilization
Efektywność odwadniania termicznie kondycjonowanych osadów ściekowych poddanych stabilizacji beztlenowej
Autorzy:
Małkowski, M.
Wolski, P.
Wolny, L.
Powiązania:
https://bibliotekanauki.pl/articles/395755.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
osady ściekowe
kondycjonowanie termiczne
stabilizacja beztlenowa
odwadnianie
sewage sludge
thermal conditioning
anaerobic stabilization
dewatering
Opis:
Thermal pretreatment of sewage sludge influences the improvement of biochemical decomposition of sludge in the anaerobic stabilization process. At the same time the ratio of fermentation impacts on the effectiveness of sludge dewatering. The aim of investigation was the evaluation of thermal conditioned excess sludge dewaterability after anaerobic stabilization process. In the tests excess and digested (10%) sludge from municipal wastewater treatment plant was used. Experiments were carried out in the laboratory flasks filled with the tested sludge and located in the laboratory incubator. Unconditioned and conditioned sludge in temperature of 50, 60, 70, 80 and 90°C was stabilised during 10 days. In each day of the process the capillary suction time (CST), thickening degree and dry matter content were determinated. Thermal conditioning of excess sludge influenced the increase of CST values. For sludge after mesophilic anaerobic stabilization in the successive days of the process, the decrease of CST values, dry matter content and thickening degree were noticed.
Wstępna termiczna obróbka osadów ściekowych wpływa na poprawę ich biochemicznego rozkładu w procesie stabilizacji beztlenowej. Stopień przefermentowania oddziaływuje tym samym na efektywność odwadniania osadów. Celem prowadzonych badań było określenie wpływu termicznego kondycjonowania osadów nadmiernych poddanych stabilizacji beztlenowej na końcowe ich odwadnianie. W badaniach wykorzystano osady nadmierne i przefermentowane (10%) pochodzące z komunalnej oczyszczalni ścieków. Badania prowadzono w kolbach laboratoryjnych, które po napełnieniu badanymi osadami umieszczono w cieplarce laboratoryjnej. Osady niekondycjonowane oraz kondycjonowane w temperaturze 50, 60, 70, 80 i 90°C poddano stabilizacji przez okres 10 dni. W każdym dniu prowadzenia procesu oznaczano czas ssania kapilarnego (CSK), stopień zagęszczania oraz zawartość suchej masy. Termiczne kondycjonowanie osadów nadmiernych wpłynęło na wzrost wartości CSK. Poddając osady mezofilowej stabilizacji beztlenowej odnotowano w kolejnych dniach prowadzenia procesu obniżenie wartości czasu ssania kapilarnego, suchej masy, jak również stopnia zagęszczenia.
Źródło:
Civil and Environmental Engineering Reports; 2011, 6; 109-115
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zespoły mikroorganizmów w procesach beztlenowej stabilizacji osadów
Complexes of microorganisms in the oxygen-free stabilization processes of sewage sludge
Autorzy:
Worwąg, M.
Bień, J.
Zawieja, I.
Powiązania:
https://bibliotekanauki.pl/articles/127055.pdf
Data publikacji:
2010
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
stabilizacja beztlenowa
mikroorganizmy beztlenowe
osady ściekowe
oxygen-free stabilization
oxygen-free microorganisms
sewage sludge
Opis:
Fermentacja metanowa jest to złożony proces przebiegający przy udziale zróżnicowanych populacji drobnoustrojów pod względem pokarmowym, ale synergistycznie zależnych od siebie. Związki makromolekularne rozkładane są do związków prostych, stanowiących substrat dla bakterii fermentacji metanowej, które następnie produkują wodór, alkohole oraz lotne kwasy tłuszczowe (LKT). LKT są zużywane przez bakterie syntroficzne z wytworzeniem octanu i wodoru. Octan może być także produkowany z wodoru i ditlenku węgla przez niektóre bakterie homoacetogenne oraz bakterie redukujące siarczany czy inne mikroorganizmy beztlenowe. Wodór, octan i inne składniki wykorzystywane są przez bakterie metanogenne do produkcji metanu. Charakterystyka zbiorowisk mikroorganizmów fermentacji metanowej pozwala na prześledzenie zmian i aktywności populacji drobnoustrojów. Substratem do badań był nadmierny osad czynny pochodzący z Koniecpolskich Zakładów Płyt Pilśniowych „Koniecpol“ S.A., zaszczepiony osadem przefermentowanym, pobranym z komunalnej oczyszczalni ścieków „WARTA” w Częstochowie. Mieszaninę poddano 25-dniowej mezofilowej fermentacji metanowej. Badania prowadzono w kolbach laboratoryjnych umieszczonych w stacji do hodowli beztlenowych BACTRON w temperaturze 37ºC. Zawartość badanych kolb mieszano co kilka godzin ręcznie. W celu poznania zakresu zmian liczbowychzbiorowisk mikroorganizmów, biorących udział w beztlenowej stabilizacji osadów ściekowych, w trakcie trwania procesu, codziennie dokonywano oznaczeń biologicznych na podłożu selektywnym, a także pomiaru odczynu pH mieszaniny osadów ściekowych wewnątrz stacji BACTRON w warunkach beztlenowych. W zakresie analiz mikrobiologicznych przeprowadzono również obserwacje mikroskopowe za pomocą mikroskopu fluorescencyjnego. Przed oraz po fermentacji metanowej dokonywano analizy fizyczno-chemicznej mieszaniny, mianowicie: suchej masy, suchej masy organicznej i mineralnej, zasadowości ogólnej, ChZT, LKT, azotu Kjeldahla, azotu amonowego, węgla ogólnego.
The methane fermentation is a sophisticated process which takes place with the participation of various populations of microorganisms in respect of culture, however, they depend on each other in a synergistic way. The macromolecular compounds are resolved into simple compounds, which are the substrates for bacteria of methane fermentation and then they produce hydrogen, alcohol, volatile fatty acids (VFA). VFA are used by syntrophic bacteria with the production of acetate and hydrogen. Acetate can also be produced from hydrogen and carbon dioxide by some homoacetogenic bacteria and by bacteria which reduce sulfates or by other oxygen-free microorganisms. Hydrogen, acetate and other components are used to produce methane by methanogenic bacteria. The characteristics of microorganisms populations of methane fermentation allows to observe the changes and the activities of the microorganisms populations. The substrate of the research was the excessive activated sludge coming from Koniecpol Fibreboard Factory “Koniecpol” S.A. inoculated by fermented sludge, taken from the municipal sewage treatment plant: WARTA in Częstochowa. The mixture was later put to the 25-day mesophile methane fermentation. The research was made in the laboratory flasks, put into the oxygen-free cultures station called BACTRON in the temperature of 37ºC. The content of the examined flasks was mixed every few hours by hand. In order to find out the range of the numerical changes of the microorganism complexes, taking place in oxygen-free stabilization of sewage sludge, during the process, there were made every day: the biological determinations on the selective base and the measurement of pH reaction of the mixture of sewage sludge inside the BACTRON station in oxygen-free conditions. Within the range of microbiological analyses there were also made the microscopic observations by mean of a fluorescent microscope. Before and after the methane fermentation there were made the physical and chemical analysis of the mixture, which includes the parameters: dry matter, dry organic and mineral matter, general alkalinity, COD (chemical oxygen demand), Kjeldahl nitrogen, ammonium nitrogen, general carbon.
Źródło:
Proceedings of ECOpole; 2010, 4, 2; 515-522
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies