Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "sensor calibration" wg kryterium: Temat


Tytuł:
A study on the calibration of an HPM meter based on a D-dot sensor and logarithmic RF power detector
Autorzy:
Jakubowski, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/1849151.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
HPM measurements
sensor calibration
RF detector
D-dot sensor
Opis:
HPM meters are required for the assessment of fields generated by sources of high-power microwaves. Finding the inverse calibration curves for such instruments is important for ensuring accuracy. The procedure is relatively simple for meters consisting of linear devices but there can also be hardware solutions implementing nonlinear ones. The objective of the present work was to develop a convenient procedure to allow finding such a curve when the meter uses a D-dot probe and a power detector. For that purpose, the results of low voltage measurements describing the properties of the detector were first analysed. Then a software code was developed to estimate the RMS value of an incident field based on measured output and frequency response. The response was estimated with very low electric field. And finally, the performance of the proposed procedure was verified by tests conducted with high electric field in a TEM cell. High conformity of the output of the meter with fields of known values was demonstrated. The maximum error related to the meter range did not exceed 4%.
Źródło:
Metrology and Measurement Systems; 2020, 27, 4; 673-685
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Developing RF Power Sensor Calibration Station in Direct Comparison Transfer System using Vector Network Analyzer
Autorzy:
Szatkowski, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/1839334.pdf
Data publikacji:
2021
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
direct comparison transfer
microwave power measurement
power sensor calibration
measurement uncertainty
VNA
Opis:
Calibration of RF power sensors is crucial issue in RF power measurements. Many calibration laboratories use the direct comparison transfer system with a signal generator and a power splitter. Increasing performance of modern vector network analyzers makes it possible to perform a power sensor calibration with acceptable uncertainties. The main advantage when using a VNA is a simple measurement setup with a wide frequency range (up to 50 GHz, limited only by the VNA and the standard power sensor), where all of required components, i.e. signal generator, a directional coupler and a reference power indicator are built in the VNA technology. This paper reports performing a VNA-based RF power sensors calibration for 10 MHz – 18 GHz band, carried out in the Laboratory of Electric, Electronic and Optoelectronic Metrology at the National Institute of Telecommunications in Warsaw, Poland. In order to validate the proposed solution two of power sensors were calibrated at a reference laboratory. The validation consisted of two steps. At first, one of those characterized power sensors was calibrated at our laboratory in direct comparison transfer system. Finally, the results obtained from the VNA-based system were compared with the previously obtained ones.
Źródło:
Journal of Telecommunications and Information Technology; 2021, 3; 18-22
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Low cost attitude and heading sensors in terrestrial photogrammetry – calibration and testing
Autorzy:
Kolecki, J.
Kuras, P.
Powiązania:
https://bibliotekanauki.pl/articles/131314.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
direct georeferencing
IMU
GPS/INS
bundle adjustment
sensor calibration
accuracy test
metoda wiązek
badanie dokładności
Opis:
Most of the contemporary terrestrial mobile mapping systems (MMSs) use tactical or navigation grade inertial measurement units (IMU) to determine the approximated angular exterior orientation (EO) elements of images. Navigation grade IMUs, usually integrated with GNSS receivers, are also used to determine the projection center coordinates. Recent researches show that using also a low-cost attitude and heading reference system (AHRS) or a low-cost IMU, satisfies the demands of certain photogrammetric applications. Our researches aim to evaluate the accuracy of low-cost devices suitable for constructing small, low-cost photogrammetric MMS. During our research two low-cost devices, providing information about image attitude and heading, were tested. The first one is the calibrated Ricoh G700SE GPS camera with an electronic compass and a level indicator. The second device is the Xsens MTi AHRS unit, comprising 3 MEMS (micro-electromechanical systems) gyros, 3 MEMS accelerometers and 3 magnetometers. For the testing purposes the AHRS was combined with the calibrated Nikon D80 SLR camera. The 3D AHRS magnetometer calibration was carried out using the manufacturer's software to compensate for the soft and hard iron effects. The images of three test fields were taken. The images of the first test field with signalized control points were used to determine the boresight rotation matrix of the AHRS. The bundle adjustment was solved separately for each camera and each test field to determine the true (reference) angular exterior orientation parameters. The differences between measured and calculated angles allowed to evaluate the accuracy of the measured angles. The tests results for the GPS camera show high residuals of measured azimuths, however its level indicator allows camera levelling with subdegree accuracy. The results obtained for the low-cost AHRS unit were significantly better, however over 2° residuals for yaw angle were also observed. The results prove the usefulness of the AHRS for constructing a small, hand-held MMS, whereas GPS camera azimuth measurements can be treated rather as a rough approximations in the photogrammetric network adjustment.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2011, 22; 249-260
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applications of regression methods to humidity sensors calibration
Zastosowanie metod regresji w kalibracji sensorów wilgotności
Autorzy:
Majewski, J.
Boyko, O.
Powiązania:
https://bibliotekanauki.pl/articles/158930.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
metoda klasyczna kalibracji liniowej
metoda odwrotna kalibracji liniowej
kalibracja sensorów wilgotności
humidity sensor calibration
classical calibration method
inverse prediction method
Opis:
The classical and inverse linear calibration methods based on the regression of y on x and the regression of x on y, were applied to several humidity sensors. The predicted values for given values of the output value of sensors were calculated, and conclusions concerning the accuracy of prediction were drawn.
Zastosowano metodę klasyczną i metodę odwrotną kalibracji liniowej oparte, odpowiednio, na regresji y względem x oraz regresji x względem y do wyznaczenia równania prostej kalibracji dla kilku sensorów wilgotności oferowanych na rynku. Przedstawiono wyniki obliczeń wartości predykowanych wilgotności dla wybranych wartości sygnału wyjściowego sensorów oraz podano wnioski dotyczące dokładności predykcji.
Źródło:
Prace Instytutu Elektrotechniki; 2011, 252; 101-106
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hardware techniques for improving the calibration performance of direct resistive sensor-to-microcontroller interface
Autorzy:
Kokolanski, Z.
Gavrovski, C.
Dimcev, V.
Makraduli, M.
Powiązania:
https://bibliotekanauki.pl/articles/221499.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
passive sensor
sensor interface
calibration
microcontroller
Opis:
Direct sensor-to-microcontroller is a simple approach for direct interface of passive modulating sensors to a microcontroller without any active components in between the sensor and the microcontroller and without an analog to digital converter. The metrological performances of such interface circuits are limited by certain microcontroller parameters which are predetermined by the manufacturing technology. These limitations can be improved by specific hardware-related techniques and can improve the accuracy, speed and resolution of the measurements. Such hardware solutions as well as proper selection of the electrical components are addressed in this paper. It has been shown that employment of only a few MOSFET transistors can reduce the maximal relative error of single point calibration more than fifteen times and can increase the measuring speed around 30 % in all calibration techniques in the measurement range of PT1000 resistive temperature sensors. Moreover, the effective number of resolution bits increases by more than 1.3 bits when using an external comparator.
Źródło:
Metrology and Measurement Systems; 2013, 20, 4; 529-542
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of variation in measurement chain on temperature measurement calibration with resistant temperature sensors
Autorzy:
Deutsch, Jessica
Riedel, Mirko
Müller, Jens
Ihlenfeldt, Steffen
Powiązania:
https://bibliotekanauki.pl/articles/99818.pdf
Data publikacji:
2019
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
temperature measurement
calibration
PRT sensor
Opis:
Temperature is one of the most important key parameter to consider in measurement and mechanical engineering, because every measurement has to be conducted with reference to standard temperature conditions (20°C, ISO 1). Strictly speaking, almost every measurement depends on the accuracy of the temperature measurement, which requires proper calibration. Therefore, standards list detailed criteria to fulfil temperature calibration with high precision. In fact, any calibration is only valid, if the whole measurement chain is taken into account. This would make recalibration necessary with each variation of the components in the measuring set-up (varying cable length, different measurement channel etc.), which is time-consuming or even impossible in practice. For that reason, this paper presents a practicable calibration strategy, which specifies each component individually and later combines the calibration results according to the composition of the measurement chain. This provides a fast and useful way to achieve the required accuracy of temperature measurement. The examined, exemplary measurement chain consists of an industrial platinum resistance thermometer (IPRT), cables with different lengths, an electrical amplifier and a reference temperature calibrator.
Źródło:
Journal of Machine Engineering; 2019, 19, 3; 56-65
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilisation of kinect sensors for the design of a human-robot collaborative workcell
Autorzy:
Kumičáková, D.
Rengevič, A.
Císar, M.
Tlach, V.
Powiązania:
https://bibliotekanauki.pl/articles/102233.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
robotized workcell
kinect sensor
calibration
ROS
Opis:
The paper deals with a present topic of utilisation of nonconventional sensors for solving the tasks of a human-robot collaboration within a shared workcell. The attention is primary focused on an exploring of possibilities of utilisation of low-cost Kinect sensors. The paper presents the methodical steps of solution of a sensor subsystem proposal within conditions of the laboratory robotised workcell, methods applied for the sensors intrinsic parameters calibration and their verification.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 270-278
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensor Calibration Design Based on D-Optimality Criterion
Autorzy:
Hajiyev, C.
Powiązania:
https://bibliotekanauki.pl/articles/220607.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sensor
calibration curve
calibration design
D-optimality criterion
least squares method
Opis:
In this study, a procedure for optimal selection of measurement points using the D-optimality criterion to find the best calibration curves of measurement sensors is proposed. The coefficients of calibration curve are evaluated by applying the classical Least Squares Method (LSM). As an example, the problem of optimal selection for standard pressure setters when calibrating a differential pressure sensor is solved. The values obtained from the D-optimum measurement points for calibration of the differential pressure sensor are compared with those from actual experiments. Comparison of the calibration errors corresponding to the D-optimal, A-optimal and Equidistant calibration curves is done.
Źródło:
Metrology and Measurement Systems; 2016, 23, 3; 413-424
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
3D Acoustic Field Intensity Probe Design and Measurements
Autorzy:
Kotus, J.
Czyżewski, A.
Kostek, B.
Powiązania:
https://bibliotekanauki.pl/articles/176807.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
sound intensity
acoustic vector sensor
calibration
measurements
Opis:
The aim of this paper is two-fold. First, some basic notions on acoustic field intensity and its measurement are shortly recalled. Then, the equipment and the measurement procedure used in the sound intensity in the performed research study are described. The second goal is to present details of the design of the engineered 3D intensity probe, as well as the algorithms developed and applied for that purpose. Results of the intensity probe measurements along with the calibration procedure are then contained and discussed. Comparison between the engineered and the reference commercial probe confirms that the designed construction is applicable to the sound field intensity measurements with a sufficient effectiveness.
Źródło:
Archives of Acoustics; 2016, 41, 4; 701-711
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological Analysis Of Microsoft Kinect In The Context Of Object Localization
Autorzy:
Skalski, A.
Machura, B.
Powiązania:
https://bibliotekanauki.pl/articles/221384.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Kinect motion sensor
localization
camera calibration
measurement precision
robustness
Opis:
This paper presents a comprehensive metrological analysis of the Microsoft Kinect motion sensor performed using a proprietary flat marker. The designed marker was used to estimate its position in the external coordinate system associated with the sensor. The study includes calibration of the RGB and IR cameras, parameter identification and image registration. The metrological analysis is based on the data corrected for sensor optical distortions. From the metrological point of view, localization errors are related to the distance of an object from the sensor. Therefore, the rotation angles were determined and an accuracy assessment of the depth maps was performed. The analysis was carried out for the distances from the marker in the range of 0.8-1.65 m. The maximum average error was equal to 23 mm for the distance of 1.6 m.
Źródło:
Metrology and Measurement Systems; 2015, 22, 4; 469-478
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór materiałów do wytworzenia pasywnych celów kalibracyjnych oraz metodyka wyznaczania terenowej zdolności rozdzielczej kamer i skanerów termalnych
Selection of materials for the development of passive calibration targets and the methodology used in determining the spatial resolution of thermal cameras and scanner
Autorzy:
Dębski, W.
Walczykowski, P.
Orych, A.
Powiązania:
https://bibliotekanauki.pl/articles/131068.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
sensor termalny
cel kalibracyjny
terenowa zdolność rozdzielcza
MTF
thermal sensor
calibration target
resolving power
Opis:
Precyzyjne wyznaczenie terenowej zdolności rozdzielczej sensorów termalnych jest problemem niezwykle istotnym przy pozyskiwaniu zobrazowań z pułapu lotniczego. Artykuł przedstawia możliwości wyznaczania terenowej zdolności rozdzielczej sensorów termalnych w oparciu o specjalnie do tego celu zaprojektowane testy kalibracyjne. Przedstawiono rodzaje istniejących termalnych celów kalibracyjnych. W artykule zostały omówione i przeanalizowane dwie podstawowe metody wyznaczania rozdzielczości terenowej na podstawie zobrazowań celów kalibracyjnych – metoda subiektywna oraz metoda obiektywna. Dokonano analizy istniejących pasywnych celów termalnych wykorzystywanych przez międzynarodowe zespoły Traktatu Open Skies. Cele, które spełniają rygorystyczne wymogi Traktatu są jednak przeważnie mało mobilne. Dlatego też prowadzone są dalsze prace nad doborem odpowiednich materiałów do wytworzenia pasywnych celów kalibracyjnych. W wyniku analizy danych pozyskanych z pomiarów Open Skies oraz własnych opracowań, można stwierdzić, że najwygodniejszym rozwiązaniem jest wykorzystanie materiałów tekstylnych do wykonania termalnych celów kalibracyjnych. Cele kalibracyjne wykorzystywane przez uczestników Traktatu Open Skies uniemożliwiają określenia zdolności rozdzielczej sensora dla dowolnej wysokości lotu. W artykule przedstawiono metodykę obiektywnego określania zdolności rozdzielczej sensora termalnego na dowolnym pułapie lotu na podstawie tkaninowych testów Siemmensa i przekoszkonej krawędzi wykorzystując do tego celu funkcję przenoszenia modulacji.
Precise determination of the resolving power of thermal sensors is of a key importance when acquiring imagery from the air. The resolving power defines the value of such imagery in many applications. The paper describes possibilities of determining the resolving power of thermal sensors based on especially designed calibration tests. The existing thermal calibration targets are presented. The paper describes and analyses two basic methods of determining the resolving power based on calibration targets: a subjective method of multiple observations and an objective method, which uses the modulation transfer function (MTF). The existing passive thermal targets used by international Open Skies Treaty groups were analysed. The targets, which comply to the rigorous requirements of the Treaty, are usually made of large metal panels, which makes them difficult to transport. Therefore research is in progress on the selection of adequate materials for the production of calibration targets. In the experimental section, a large array of materials such as textiles as well as panels made out of wood, steel and aluminium of different finishes and covered with paints of different emissivities, were examined in the thermal range. Analysis of the authors' own measurements as well as those taken by Open Skies groups allows to conclude that the use of textiles is the most convenient solution for developing a thermal calibration target. Such a target is easy to transport and very convenient to experiment with in the field. Furthermore, development of such a target is simple and does not require any complex, specialised production methods. Calibration targets used by the Open Skies Treaty members make it possible to only subjectively establish the flight altitude, for which the resolving power of the sensor will not exceed 40, 50 or 60cm. They do not, however, allow to determine the resolving power of the sensor for any given flight altitude. The paper presents also an objective method for determining the resolving power of thermal sensors for any flight altitude based on the modulation transfer function used on two textile targets: a Siemmens star and slanted edge test.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2008, 18a; 73-81
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Komputerowe stanowisko do badania czujników temperatury
Computer stand for testing temperature sensors
Autorzy:
Leśnikowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/151394.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiary temperatury
czujnik temperatury
kalibracja
temperature measurements
temperature sensor
calibration
Opis:
W artykule przedstawiono krótką charakterystykę zbudowanego stanowiska do badania tekstronicznych czujników temperatury. Opisano jego konstrukcję, podstawowe dane techniczne. Podano przykładowe wyniki pomiarów.
In the paper the short characteristic of measuring unit for textronic, temperature sensors calibration were described. Stand construction, basic technical data of stand elements and an example test was also presented.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 42-43
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania nad wpływem rozmieszczenia fotopunktów na jakość kalibracji obrazu QuickBird 2 metodą fizycznego modelu sensora
A study of the influence of gcp distribution on the quality of QuickBird 2 image calibration using the physical sensor model
Autorzy:
Zdunek, Z.
Wyczałek, I.
Powiązania:
https://bibliotekanauki.pl/articles/129974.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
QuickBird
kalibracja geometryczna
fizyczny model kamery
geometric calibration
rigorous sensor model
Opis:
Przedmiotem pracy jest analiza wpływu osnowy fotogrametrycznej na dokładność kalibracji fragmentu sceny wysokorozdzielczego zobrazowania satelitarnego metodą fizycznego modelu kamery. Analizowano, czy wyniki ortorektyfikacji poprzedzonej kalibracją obrazu zależą od konfiguracji fotopunktów. Obiektem badań był obszar 5×5 km w centrum Poznania, o deniwelacjach nie przekraczających 30 m. Wykorzystano obraz QuickBird 2 o doskonałej jakości radiometrycznej, zapisany w formacie Standard OrthoReady. Dobrano kontrastujące z otoczeniem fotopunkty w równomiernym rozkładzie 4 linie po 4 punkty. W pobliżu fotopunktów zlokalizowano po 1-3 punktów kontrolnych. Wszystkie punkty pomierzono techniką GPS-RTK z błędem m p = ±24 mm i m H = ±45 mm. Równomiernemu rozkładowi fotopunktów przeciwstawiono pięć przypadków rozmieszczenia niesymetrycznego. Wyniki kolejnych wyrównań w przyjętych fotopunktach w zasadzie nie różnią się od przypadku wzorcowego, natomiast znacznie wzrastają na punktach kontrolnych, osiągając w kolejnych niekorzystnych konfiguracjach nawet 20-krotnie większe wartości. Z analizy wyników badań wywnioskowano potrzebę doboru nawet minimalnej liczby 8 fotopunktów, ale równomiernie rozmieszczonych na obrzeżu opracowywanego fragmentu sceny, aby uzyskać podpikselowe dokładności ortofotomapy nawet, gdy ten fragment leży z boku sceny.
The subject of this paper is an analysis of the influence of a photogrammetric reference net on the accuracy of the calibration of very high resolution satellite imagery using a rigorous sensor model. It was studied whether the results of orthorectification preceded by image calibration depend on configuration of Ground Control Points. The test field was an area of 5×5 km of central Poznan with level differences of less than 30 m. An OrthoReady QuickBird 2 image with excellent radiometric quality was used. The GCPs (contrasted with the surroundings and distributed into 4 lines by 4 points) were selected. 1-3 Check Points were placed near of each of them. All points were measured with the GPS\RTK method with a horizontal mean error m p =±24 mm and vertical error m H =±45 mm. Against the regular distribution of points, five irregular ones were set off. The first three cases are rather untypical and concern the distribution of GCP’s diagonally (1), at the edge (2) and along vertical axis of the image (3). In cases 4 and 5, the points are randomly scattered in the image. The results of consecutive adjustments in the given GCPs did not differ from the model case, but significantly increased at the Check Points – achieving up to 20-times greater values in consecutive configurations. From the analyses of results, a need was determined to select even a minimum number of 8 GCPs, but regularly distributed on the peripheries of the treated part of the scene to achieve subpixel accuracy of the orthophotomap, even if this part lies at the side of the scene.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2006, 16; 597-607
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Piezoelektryczny czujnik przyspieszeń (akcelerometr) do jednorazowych badań niszczących
Disposable piezoelectric sensor of accelerations (accelerometer) for destructive tests
Autorzy:
Faryński, Andrzej
Ziółkowski, Zbigniew
Wijaszka, Mirosław
Kamiński, Roman
Powiązania:
https://bibliotekanauki.pl/articles/2134900.pdf
Data publikacji:
2022
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
czujnik piezoelektryczny
skalowanie czujników
badania niszczące
piezoelectric sensor
calibration of sensors
destructive tests
Opis:
W artykule przedstawiono założenia konstrukcyjne i budowę opracowanych oraz wykonanych w ITWL tanich piezoelektrycznych akcelerometrów do badań niszczących na zakres do ok. 4000 g. W układach wykorzystano płytki piezoceramiczne z rezonatorów 455 kHz. Opisano sposób ich skalowania i wyznaczono czułości, zawierające się w granicach 0,37 ÷ 0,72 mV/g, przy dokładności < 10%.
The paper presents designing specifications and structure of cheap piezoelectric accelerometers on the range up to ca. 4000g developed and made in the AFIT (Air Force Institute of Technology) for destructive tests. Piezoelectric 455 kHz resonating plates were used for the units. Their calibration was described and sensitivity determined on 0.37 ÷ 0.72 mV/g at accuracy < 10%.
Źródło:
Problemy Techniki Uzbrojenia; 2022, 51, 159; 73--86
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calibration method for a laser triangulation distance sensor
Metoda kalibracji penetrometru laserowego
Autorzy:
Wojutyński, J.
Zbrowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/257795.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
prototype
testing
calibration
laser triangulation distance sensor
prototyp
badanie
kalibracja
laserowy triangulacyjny czujnik pomiarowy
Opis:
The article presents a calibration method for a measuring circuit with a laser triangulation distance sensor. The authors describe factors influencing the accuracy of measurement using a laser triangulation sensor. The computer software supporting calibration procedure was developed, and the control-measuring software of the penetrometer was modified. The method is the result of the process of improvement of the penetrometer. The application of the developed penetrometer calibration method helps to achieve assumed measuring accuracy of ±2 units of penetration.
W artykule przedstawiono metodę kalibracji toru pomiarowego z laserowym triangulacyjnym czujnikiem odległości. Omówiono czynniki wpływające na dokładność pomiaru za pomocą triangulacyjnego czujnika laserowego. Opracowano oprogramowanie komputerowe wspomagające procedurę kalibracji oraz zmodyfikowano oprogramowanie pomiarowo-sterujące penetrometru. Metoda jest wynikiem procesu doskonalenia penetrometru. W wyniku aplikacji opracowanej metody kalibracji penetrometru uzyskano zakładaną dokładność pomiaru ±2 jednostki penetracji.
Źródło:
Problemy Eksploatacji; 2014, 1; 119-129
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies