Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "self-oscillation" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Oscillation criteria for second order self-adjoint matrix differential equations
Autorzy:
Parhi, N.
Praharaj, P.
Powiązania:
https://bibliotekanauki.pl/articles/1293939.pdf
Data publikacji:
1999
Wydawca:
Polska Akademia Nauk. Instytut Matematyczny PAN
Tematy:
matrix differential equations
self-adjoint
oscillation
Opis:
Some results concerning oscillation of second order self-adjoint matrix differential equations are obtained. These may be regarded as a generalization of results for the corresponding scalar equations.
Źródło:
Annales Polonici Mathematici; 1999, 72, 1; 1-14
0066-2216
Pojawia się w:
Annales Polonici Mathematici
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of self-oscillation in wire gauges
Autorzy:
Cieplok, G.
Kopij, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/279367.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
self-oscillation
wire transducer
Opis:
In the presented paper, an original solution to the system maintaining vibrations of a wire transducer, which has been based upon the phenomenon of self-oscillation, is described. The vibrations generated in this manner do not fade in time, are resistant to disturbances and allow measurement of the signal rapidly changing in time. The dynamic equations and numerical simulations of motion of the wire interconnected with the van der Pol oscillator are presented. Based on the conceptual model, a laboratory stand has been built, which served to verify properties of the presented solution and possibilities of useful applications.
Źródło:
Journal of Theoretical and Applied Mechanics; 2017, 55, 1; 29-39
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of cable length on the vibrating wire sensors dynamic measurements
Wpływ długości kabli na dynamiczne pomiary czujnikami strunowymi
Autorzy:
Cieplok, G.
Karwowski, W.
Bednarski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/231479.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
czujnik strunowy
monitoring techniczny
maszt żaglowca
most
stan przejściowy
połączenie kablowe
drgania samowzbudne
vibrating wire sensor
structural health monitoring
tall ship mast
bridge
transient state
cable connection
self-oscillation
Opis:
The hereby paper discusses the influence of cable length on the SHM systems with the use of vibrating wire dynamic measurements. Vibrating wire sensors are mainly used for measuring stable or slowly changing strains, e.g. system installed on Rędziński Bridge in Wroclaw. From some time applications of these sensors for measuring dynamic deformations are becoming popular. Such tests were conducted on STS Fryderyk Chopin. New solutions generate new problems. In this case: the operational stability of systems exciting wire vibrations. The structure of such sensors and the electric cables length has an essential influence on their operations, what is undertaken in the paper. The subject of investigations constitutes the measuring system based on self-exciting impulse exciter, for which impedance parameters of electric cables and of the vibrating wire sensor were the most essential. The mathematical model of the system, experimental verification of the model as well as the results of theoretical analyses at the application of electric cables of various lengths are presented in the paper.
Artykuł porusza temat wpływu długości kabli na możliwość budowy systemów monitorowania konstrukcji z wykorzystaniem dynamicznych pomiarów strunowych. Rozważania przeprowadzono na przykładzie polskiego urządzenia pomiarowego przeznaczonego do dynamicznych pomiarów strunowych. Czujniki strunowe są szeroko stosowanym narzędziem w pomiarach i monitorowaniu konstrukcji. Znalazły zastosowanie w kontroli stanu technicznego mostów, tam, tuneli, stadionów. Swoją popularność zawdzięczają prostej budowie, pełnej odporności na warunki środowiskowe oraz bardzo długiej stabilności czasowej wynoszącej, wg badań Norweskiego Instytutu Geotechnicznego, ponad 30 lat. Ponieważ informacja o mierzonej wielkości jest przenoszona przez zmiany napięcia (częstotliwość) to czujniki strunowe mogą pracować z kablami o długościach dochodzących do 12 km, co pozwala na umieszczanie czujników w dowolnych miejscach konstrukcji, często niedostępnych i podłączanie ich do urządzeń elektronicznych znajdujących się w łatwo dostępnym do serwisowania miejscu.
Źródło:
Archives of Civil Engineering; 2018, 64, 4/II; 65-76
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies