Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "selective non-catalytic reduction" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
The application of RANS CFD for design of SNCR technology for a pulverized coal-fired boiler
Autorzy:
Ruszak, M.
Inger, M.
Wilk, M.
Nieścioruk, J.
Saramok, M.
Kowalik, W.
Rajewski, J.
Wajman, T.
Kacprzak, W.
Tadasiewicz, D.
Powiązania:
https://bibliotekanauki.pl/articles/778027.pdf
Data publikacji:
2017
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
NOx emission abatement
power plant boilers
selective non-catalytic reduction
flue gas treatment
Opis:
The article describes the technology of NOx  emission abatement by SNCR method. The scope of research included CDF simulations as well as design and construction of the pilot plant and tests of NOx  reduction by urea in the plant located in industrial pulverized-coal fired boiler. The key step of research was to determine the appropriate temperature window for the SNCR process. The proposed solution of the location of injection lances in the combustion chamber enabled to achieve over a 30% reduction of NOx . It is possible to achieve higher effectiveness of the proposed SNCR technology and meet the required emission standards via providing prior reduction of NOx  to the level of 350 mg/um3 using the primary methods.
Źródło:
Polish Journal of Chemical Technology; 2017, 19, 2; 101-106
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania lanc rozpylających przeznaczonych do niekatalitycznej redukcji tlenków azotu (SNCR) w kotłach o małej mocy
Investigation of spraying lances used in low power boilers for non-catalytic reduction of nitrogen oxides (SNCR)
Autorzy:
Krzywda, R.
Wrzesińska, B.
Wąsowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/1208806.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
selektywna niekatalityczna redukcja tlenków azotu
SNCR
lance rozpylające
oczyszczanie spalin
selective non-catalytic reduction N oxides
spraying lances
flue gas purification
Opis:
W związku z zaostrzeniem norm emisji tlenków azotu z instalacji energetycznych o małej mocy w bliskiej perspektywie czasowej, niezbędne będzie wyposażenie ich w instalacje redukujące NOx. Metoda selektywnej niekatalitycznej redukcji tlenków azotu SNCR wymaga lanc rozpylających o odpowiedniej charakterystyce. W pracy omówiono zagadnienie doboru tych urządzeń, metodykę badania ich charakterystyki oraz wybrane wyniki pomiarów. Ponadto przedstawiono prostą metodę pomiaru średnic kropel w strudze rozpylonej cieczy.
Shortly, according to more restrictive norms concerning emission of nitrogen oxides, all low power plans will have to possess appropriate sections for NOx reduction. Method of selective non-catalytic reduction of nitrogen oxides (SNCR) uses spraying lances with an appropriate characteristics. In this paper selection of the proper lances, methodology of their characteristic investigations as well as some experimental results of their application are presented. Moreover, a simple method for determination of mean drop diameters in a spray is also shown.
Źródło:
Chemik; 2016, 70, 10; 605-610
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental investigation of N2O formation in selective non-catalytic NOx reduction processes performed in stoker boiler
Autorzy:
Krawczyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/779234.pdf
Data publikacji:
2016
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
selective non-catalytic reduction process
nitrous oxide emissions
stocker boiler
Opis:
Stoker fired boiler plants are common throughout Eastern Europe. Increasingly strict emission standards will require application of secondary NOx  abatement systems on such boilers. Yet operation of such systems, in addition to reducing NOx  emissions, may also lead to emission of undesirable substances, for example N2O. This paper presents results of experimental tests concerning N2O formation in the selective non-catalytic NOx  emission reduction process (SNCR) in a stoker boiler (WR 25 type). Obtained results lead to an unambiguous conclusion that there is a dependency between the NOx  and N2O concentrations in the exhaust gas when SNCR process is carried out in a coal-fired stoker boiler. Fulfilling new emission standards in the analysed equipment will require 40–50% reduction of NOx  concentration. It should be expected that in such a case the N2O emission will be approximately 55–60 mg/m3, with the NOx  to N2O conversion factor of about 40%.
Źródło:
Polish Journal of Chemical Technology; 2016, 18, 4; 104-109
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
NOX-reduction on HD-vehicles-low cost quality check
Autorzy:
Czerwinski, J.
Zimmerli, Y.
Mayer, A.
Heeb, N.
Berger, H.
D‘Urbano, G.
Powiązania:
https://bibliotekanauki.pl/articles/246300.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
Diesel particle filter
regeneration of DPF
non-legislated emissions
selective catalytic reduction SCR
NOx-reduction
SCR-quality testing
on vehicle testing
Opis:
The NOx reduction of recent HD-vehicle is performed mostly by means of the selective catalytic reduction SCR. There are some manufactures and some applications of SCR as retrofit systems (mostly for the low emission zones LEZ and in combination with a DPF). In charge of Swiss authorities AFHB investigated several SCR-systems, or (DPF+SCR)-systems on HD-vehicles and proposed a simplified quality test procedure of those systems. This procedure can especially be useful for the admission of retrofit systems but it can also be helpful for the quality check of OEM-systems. In the present paper the test procedures will be described and some examples of specific results will be presented. As general conclusions it can be stated: – the foundations for the quality verification procedures of SCR-systems are established, – the SCR-systems are not active at lower temperatures < 200°C, – SCR-testing on vehicle is a simple & low-cost tool for quality check, – the overall average NOx reduction rate depends on the operating profile of the vehicle – for low-load, for cold operation and for interrupted operation (HEV) there are lower NOx reduction efficiencies.
Źródło:
Journal of KONES; 2013, 20, 2; 61-68
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies