Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "seismic response" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
2D numerical analysis of the seismic response of a karst rock mass: importance of underground caves and geostructural details
Autorzy:
Giovanni, Bruno
Fabrizio, Carucci
Powiązania:
https://bibliotekanauki.pl/articles/178382.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
2D local seismic response analysis
rock mass
karstic underground caves
Opis:
The present study shows the results of a 2D local seismic response (LSR) analysis, simulated for a geomechanical model consisting of a layered carbonate rock mass with hypogean karst caves and a structural–lithostratigraphic complex setting, in an area within the Municipality of Turi (Apulia, Italy). In this case study a Distinct Element Code (DEM) code (UDEC) was used for the LSR simulations conducted on a model both in the absence and in the presence of two overlapping karst caves. The preliminary stress–strain model analysis show some tensile yielding points clustered on the roof of the upper karst cave, already in static conditions, and the phenomenon becomes even more noticeable in dynamic conditions. This is perfectly in agreement with the real occurrence of a sinkhole that brought to the light the underlying karst cave, in the case study area, in the recent past. The amplification/deamplification factor (FA) was calculated as the ratio of the top value to the bottom value in the model, both of the max X-acceleration and of the spectral Fourier amplitude in three different ranges of frequencies, in order to estimate the effects of LSR on the X-component of the seismic input. According to the previous studies, the results obtained show a generalised deamplification of the seismic ground motion at the top of the model, both without and with underground karst caves, caused by the presence of the upper karst cave and by the seismic energy absorption because of layers’ discontinuity.
Źródło:
Studia Geotechnica et Mechanica; 2020, 42, 1; 61-73
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stiffness effects of structural elements on the seismic response of RC high-rise buildings
Wpływ sztywności elementów konstrukcyjnych na reakcję sejsmiczną wieżowców z żelbetu
Autorzy:
Kontoni, D. P. N.
Farghaly, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/231212.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
element konstrukcyjny
żelbet
sztywność
reakcja sejsmiczna
budynek wysoki
structural element
reinforced concrete
stiffness
seismic response
high-rise building
Opis:
The stiffness of structural elements (columns, beams, and slabs) significantly contributes to the overall stiffness of reinforced concrete (RC) high-rise buildings (H.R.B.s) subjected to earthquake. In order to investigate what percentage each type of element contributes to the overall performance of an H.R.B. under seismic load, the stiffness of each type of element is reduced by 10% to 90%. A time history analysis by SAP2000 was performed on thirteen 3D models of 12-story RC buildings in order to illustrate the contribution of column stiffness and column cross sections (rectangular or square), building floor plans (square or rectangular), beam stiffness and slab stiffness, on building resistance to an earthquake. The stiffness of the columns contributed more than the beams and slabs to the earthquake resistance of H.R.B.s. Rectangular cross-section columns must be properly oriented in order for H.R.B.s and slender buildings to attain the maximum resistance against earthquakes.
Aby zbadać, jaki procent każdego rodzaju elementów (słupów, belek i płyt) wpływa na ogólną sztywność i wydajność wieżowców (H.R.B.) pod obciążeniem sejsmicznym, sztywność każdego elementu jest zmniejszana o 10% do 90%. Analiza historyczna przeprowadzona przez SAP2000 obejmowała trzynaście modeli 3D 12-piętrowych wieżowców w celu zobrazowania wpływu sztywności i przekrojów słupa (prostokątnego lub kwadratowego), planu pięter budynku (kwadratowego lub prostokątnego), sztywności belki oraz sztywności płyty, na odporność budynku na trzęsienie ziemi. Sztywność słupa miała większy wpływ niż sztywność belki i płyty na odporność wieżowca na trzęsienie ziemi.
Źródło:
Archives of Civil Engineering; 2018, 64, 1; 3-20
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of vertical ground motion on seismic responses of triple friction pendulum interlayer isolation structures
Autorzy:
Fang, Zhao
Yan, Ping
Powiązania:
https://bibliotekanauki.pl/articles/1852324.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ruch gruntu pionowy
struktura
izolacja międzywarstwowa
odpowiedź sejsmiczna
wahadło z potrójnym tarciem
vertical ground motion
interlayer isolation
structure
seismic response
triple friction pendulum
Opis:
In order to investigate the influence of vertical ground motion on seismic responses of story-isolation structures mounted on triple friction pendulum (TFP) bearings, the finite element model of a six-story building with various types of interlayer isolation TFP bearings under far field or near fault ground motions is established and analysed. A discrepancy rate function of peak interlayer shear, acceleration and displacement results is adopted to discuss the influence of the vertical seismic motions on isolation structural responses. Furthermore, the isolation form, the isolation period and the friction coefficient of bearings are changed to study their effect on the vertical seismic component’s influence. The results show that the influence of the vertical seismic component is considerable on the isolation layer especially under near-fault ground motions, so it should not be overlooked during the structural design; The change of isolation forms will greatly affect the influence of the vertical seismic component especially in the isolation layer and isolation systems with isolation devices set on higher stories or with less isolation layers will have less vertical seismic effect on story acceleration; The increase of the isolation period will globally result in the decrease of the influence of vertical seismic components, though in some cases it shows some sort of fluctuation before the final decrease; The increase of the friction coefficient will lead to the global decrease in the influence of the vertical seismic component in single-layer isolation structures, while it does not obviously affect those in the multi-layer isolation systems.
Źródło:
Archives of Civil Engineering; 2021, 67, 3; 581-597
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seismic evaluation of deficient reinforced concrete weak beam-column joint frames
Autorzy:
Rizwan, Muhammad
Ahmad, Naveed
Khan, Akhtar Naeem
Fahad, Muhammad
Powiązania:
https://bibliotekanauki.pl/articles/1849753.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
rama żelbetowa
moment wyjątkowy
rama odporna
współczynnik modyfikacji odpowiedzi
połączenie belka-słup
odpowiedź sejsmiczna
reinforced concrete
frame structure
special moment
resisting frame
response modification factor
beam-column joint
seismic response
Opis:
The use of old building design codes and improper execution of recent seismic design practices have caused large amount of substandard and vulnerable reinforced concrete RC building stock majority of which are built with weak beam-column joint connections defect (i.e. joint panel having no transverse reinforcement and built in low strength concrete). In order to understand the seismic response and damage behaviour of recent special moment resisting frame SMRF structures with the defect of weak beam-column joints, shake table tests have been performed on two 1:3 reduced scaled, two story RC frame models. The representative reference code design and weak beam-column joint frame models were subjected to uni-directional dynamic excitations of increasing intensities using the natural record of 1994 Northridge Earthquake. The input scaled excitations were applied from 5% to 130% of the maximum input peak ground acceleration record, to deformed the test models from elastic to inelastic stage and then to fully plastic incipient collapse stage. The weak beam-column frame experienced column flexure cracking, longitudinal bar-slip in beam members and observed with cover concrete spalling and severe damageability of the joint panels upon subjected to multiple dynamic excitations. The deficient frame was only able to resist 40% of the maximum acceleration input as compared to the code design frame which was able to resist about 130%. The seismic performance of considered RC frames was evaluated in terms of seismic response parameters (seismic response modification, overstrength and displacement ductility factors), for critical comparison.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 429-451
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigating the performance of isolation systems in improving the seismic behavior of urban bridges. A case study on the Hesarak Bridge
Autorzy:
Edalati, Ali Akbar
Tahghighi, Hossein
Powiązania:
https://bibliotekanauki.pl/articles/230372.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
most żelbetowy
odpowiedź sejsmiczna
łożysko gumowe elastomerowe
łożysko gumowe ołowiowe
historia czasu
analiza
reinforced concrete bridge
seismic response
elastomeric rubber bearing
ERB
lead rubber bearing
LRB
time history
analysis
Opis:
This paper investigates the influence of isolation systems on the seismic behavior of urban reinforce concrete bridge. The performance of the Hesarak Bridge constructed in Karaj city, Iran with two isolation systems; i.e. the existing elastomeric rubber bearing (ERB) and a proposed lead rubber bearing (LRB) is discussed. The numerical model was implemented in the well-known FEM software CSIBridge. The isolated bridge has been analyzed using nonlinear time history analysis method with seven pairs of earthquake records and the results are compared for the two isolation systems. The LRB isolators are shown to have superior seismic performance in comparison with the existing ERB systems based on the response evaluation including force on the isolator, pier base shear, deck acceleration, bending moment, pier displacement, and energy dissipation.
Źródło:
Archives of Civil Engineering; 2019, 65, 4; 155-175
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Simulation of seismic response of reinforced concrete beam-column joints with NURBS surface fitting
Symulacja reakcji sejsmicznej łączników belkowo-słupowych wykonanych z betonu zbrojonego z dostosowaniem powierzchni NURBS
Autorzy:
Tabatabaei Mirhosseini, R.
Powiązania:
https://bibliotekanauki.pl/articles/231324.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
krzywa B-sklejana
NURBS
powierzchnia reakcji sejsmicznej
SRS
połączenie belka-słup
łącznik z betonu zbrojonego
model analityczny
algorytm genetyczny
właściwości tektoniczne
B-spline
seismic response surface
beam-column joint
reinforced concrete joint
analytical model
genetic algorithm
tectonic characteristics
Opis:
This paper presents an approach based on NURBS (non-uniform rational B-splines) to achieve a seismic response surface (SRS) from a group of points obtained by using an analytical model of RC joints. NURBS based on the genetic algorithm is an important mathematical tool and consists of generalizations of Bezier curves and surfaces and B-splines. Generally, the accuracy of the design process of joints depends on the number of control points that are captured in the results of experimental research on real specimens. The values obtained from the specimens are the best tools to use in seismic analysis, though more expensive when compared to values simulated by SRSs. The SRS proposed in this paper can be applied to obtain surfaces that show site effect results on destructions of beam-column joint, taking into account different site conditions for a specific earthquake. The efficiency of this approach is demonstrated by the retrieval of simulated-versus-analytical results.
W niniejszej pracy przedstawiono technikę aproksymacji, opartą na niejednorodnych powierzchniach krzywych B-sklejanych (NURBS), z wykorzystaniem algorytmu genetycznego (GA), w celu uzyskania powierzchni reakcji sejsmicznej (SRS) łączników belkowo-słupowych wykonanych z betonu zbrojonego (RC). NURBS oparta na algorytmie genetycznym jest ważnym narzędziem matematycznym i składa się z uogólnień krzywych i powierzchni Beziera oraz krzywych B-sklejanych. Techniki aproksymacji w tym kontekście zwykle obejmują dostosowanie krzywej lub powierzchni za pośrednictwem zestawu punktów danych, które są narażone na pewne błędy. Ogólnie rzecz biorąc, dokładność procesu projektowania łączników belkowo-słupowych zależy od liczby punktów kontrolnych pozyskanych z wyników badań eksperymentalnych prowadzonych na rzeczywistych próbkach. Oczywistym jest fakt, że wartości mierzone na rzeczywistych próbkach są najlepszymi narzędziami do wykorzystania w analizie sejsmicznej, przy czym są jednak droższe w porównaniu do wartości symulowanych przez SRS. SRS zaproponowane w niniejszej pracy można zastosować w celu uzyskania powierzchni, które oceniały wpływ lokalizacji na zniszczenia łącznika belkowo-słupowego, biorąc pod uwagę róźne warunki lokalizacyjne dla określonego trzęsienia ziemi. Z tego powodu dokonano wyboru trzech modeli eksperymentalnych, w celu zatwierdzenia modelu łączników. Krok po kroku zastosowano nieliniową analizę FEM. Niezbędne współczynniki elastyczności zostały opracowane na podstawie metody poszczególnych członków. Następnie obliczono reakcję czterech modeli analitycznych, poddanych różnym falom sejsmicznym. Kolejnym krokiem była ocena dostosowania powierzchni NURBS na podstawie wyników uzyskanych przez GA w punktach kontrolnych, które mogą być rozwiązane w podanych rozproszonych punktach, obliczonych na podstawie modeli analitycznych. Zaprezentowano liczbowe i graficzne wyniki, które wskazywały, że aktualna metoda generuje prawidłowe SRS z błędnym dostosowaniem. Możliwość zastosowania tej metody została potwierdzona w odniesieniu do pogorszenia szacunków dotyczących łączników RC pod wpływem różnych wejściowych ruchów sejsmicznych i klas lokalizacji.
Źródło:
Archives of Civil Engineering; 2017, 63, 3; 71-84
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seismic evaluation of mixed steel and RC columns in hybrid high-rise buildings
Autorzy:
Kontoni, D. P. N.
Farghaly, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/230311.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
budynek wysoki
konstrukcja hybrydowa
budynek żelbetowo-stalowy
belka żelbetowa
płyta żelbetowa
kolumna żelbetowa
kolumna stalowa
odpowiedź sejsmiczna
konstrukcja odporna na trzęsienia ziemi
odporność na wstrząsy sejsmiczne
high-rise building
hybrid structure
reinforced concrete steel building
reinforced concrete beam
reinforced concrete slab
reinforced concrete column
steel column
seismic response
earthquake-resistant structure
Opis:
The growth in high-rise building construction has increased the need for hybrid reinforced concrete and steel structural systems. Columns in buildings are the most important elements because of their seismic resistance. Reinforced concrete (RC) columns and steel columns were used herein to form hybrid structural systems combining their distinct advantages. Eleven 3D building models subjected to earthquake excitation with reinforced concrete beams and slabs of 12 floors in height and with different distributions of mixed columns were analyzed by the SAP2000 software in order to investigate the most suitable distributions of a combination of reinforced concrete and steel columns. Top displacements and accelerations, base normal forces, base shear forces, and base bending moments were computed to evaluate the selected hybrid structural systems. The findings are helpful in evaluating the efficiency of the examined hybrid high-rise buildings in resisting earthquakes.
Źródło:
Archives of Civil Engineering; 2019, 65, 2; 3-17
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Seismic ground response analyses at an international airport in northern Italy by using a stochastic-based
Autorzy:
Bozzoni, Francesca
Ozcebe, Ali Güney
Balia, Andrea
Lai, Carlo Giovanni
Borzi, Barbara
Nascimbene, Roberto
Ippoliti, Lucia
Berardi, Simona
Trombetti, Marco
Moroni, Claudio
Powiązania:
https://bibliotekanauki.pl/articles/1839647.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
airport
ground response
seismic microzonation
stochastics mechanics
GIS (Geo-graphical Information System)
Opis:
Airports play a crucial role in mitigation of seismic-induced disasters, being key elements in rescue operations after an earthquake. Under earthquake loading, various airport compo- nents can be damaged because of the ground shaking. It is well known that seismic ampli- fication of ground motion at the surface is strongly influenced by geotechnical properties of the soil deposits. In this paper, the spatial variability of ground amplification is assessed with reference to an international airport in Northern Italy. Homogeneous zones from a seismic geotechnical viewpoint were identified at the airport and, for each zone, stochastic ground response analyses carried out.
Źródło:
Journal of Theoretical and Applied Mechanics; 2020, 58, 2; 499-511
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Geofony w sejsmice inżynierskiej
An overview of technical parameters of geophones used in seismic engineering
Autorzy:
Pilecki, Z.
Harba, P.
Adamczyk, A.
Krawiec, K.
Pilecka, E.
Powiązania:
https://bibliotekanauki.pl/articles/164285.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
sejsmika inżynierska
klasyfikacja czujników sejsmicznych
sejsmometr
geofon
akcelerometr
czujniki trójskładowe
parametry techniczne geofonów
odpowiedź impulsowa
tłumienie
seismic engineering
seismic sensor classification
seismometer
geophone
accelerometer
three-component sensors
geophone technical parameters
impulse response
damping
Opis:
W sejsmice inżynierskiej czujniki służą jako rejestratory drgań mechanicznych ośrodka geologicznego. W pracy przedstawiono ich klasyfikację. Do najbardziej powszechnych należą geofony, które stosuje się do badań geologiczno-inżynierskich, hydrogeologicznych, geotechnicznych, geomechanicznych oraz w górnictwie. Prawidłowy dobór ich parametrów technicznych ma znaczący wpływ na jakość uzyskanych danych oraz rozdzielczość metody. Najważniejszymi parametrami, które należy wziąć po uwagę to: częstotliwość własna, czułość, tłumienie, zniekształcenia harmoniczne i oporność cewki. Bardzo istotny jest również sposób przytwierdzenia geofonu do podłoża, ponieważ może on znacząco wpływać na odpowiedź impulsową układu pomiarowego. Światowi producenci geofonów oferują szeroki zakres urządzeń o różnych wartościach parametrów technicznych do jak najlepszej akwizycji danych w konkretnych zastosowaniach sejsmicznych. Dodatkowo, nowoczesne geofony trójskładowe mogą rejestrować jednocześnie w trzech kierunkach, co ułatwia identyfikację fal sejsmicznych i opis pola falowego. W artykule dokonano możliwie szerokiego przeglądu podstawowych parametrów technicznych geofonów czołowych producentów na świecie. Sformułowano kryteria doboru geofonów do badań sejsmicznych.
Sensors are used in seismic engineering to record mechanical oscillations of geological medium. This paper presents a classification of the applied detectors. The most common are geophones which used in geological engineering, hydrogeology, geotechnical engineering and mining. Proper choice of the geophone technical parameters is essential for the obtained data quality and seismic resolution. The most important parameters are natural frequency, sensitivity, damping, harmonic distortion and coil resistivity. Geophone coupling to the ground is crucial because of its great impact on impulse response. The global producers of geophones offer a wide range of devices with different technical parameters in order to obtain the best seismic acquisition. Moreover, the newest three-component geophones record in three dimensions simultaneously. It simplifies wave identification and characterization of the wave field. This paper presents a possibly wide overview of geophone basic technical parameters produced by the leading geophysical companies worldwide. Criteria of their selection were formulated as well.
Źródło:
Przegląd Górniczy; 2014, 70, 7; 12-21
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Resilience of Eccentrically Braced Frames Equipped with Shape Memory Alloys
Autorzy:
Pirmoghan, Hamid
Khoshravi, Hossein
Sadeghi, Abbasali
Pouraminian, Majid
Noroozinejad Farsangi, Ehsan
Powiązania:
https://bibliotekanauki.pl/articles/27314709.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
shape memory alloy
SMA
super-elastic behaviour
response modification factor
shape memory effect
reduction factor
seismic resilience
stop z pamięcią kształtu
współczynnik modyfikacji
współczynnik redukcji
odporność sejsmiczna
Opis:
Nowadays, the use of smart materials in structures is a major concern to structural engineers. The act of benefiting from numerous advantages of these materials is the main objective of researches and studies focused on seismic and structural engineering. In the present study, in addition to the development of finite element models of several steel frames using ABAQUS software, the effect of shape memory alloys (SMAs) on superelastic behavior and the various types of eccentric braces will be checked. Moreover, it was observed that the use of SMAs within various types of bracing systems of steel frames leads to a decrease in the reduction factor of the frames. Also, the eccentric bracing in which SMAs are utilized in the middle of bracing led to the highest effect on reduction of lateral drift of the frames and decrease of reduction factor. The obtained results indicated that the application of smart materials led to increasing of strain energy and base shear of the first plastic hinge, which is followed by a decrease in the reduction factor of the frame.
Źródło:
Civil and Environmental Engineering Reports; 2022, 32, 1; 176--190
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determining the dynamic resistance of existing steel industrial hall structures for areas with different seismic activity
Wyznaczanie odporności dynamicznej istniejących hal przemysłowych o konstrukcji stalowej dla obszarów o różnej aktywności sejsmicznej
Autorzy:
Rusek, J.
Słowik, L.
Firek, K.
Pitas, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849754.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność dynamiczna
analiza spectrum odpowiedzi
wstrząs górniczy
konstrukcja stalowa
hala przemysłowa
teren sejsmiczny
dynamic resistance
spectrum response analysis
mining tremor
steel structure
industrial hall
seismic activity area
Opis:
The paper presents the results of research concerning the assessment of dynamic resistance of existing industrial hall structures located in areas with different seismic activity. The basis for analyses was a three-nave industrial hall with a steel structure. Numerical calculations were performed using the finite element method (FEM), using the response spectrum method in dynamic analysis. The calculations were carried out in variants, using standard accelerated response spectra according to Eurocode 8 and those determined for the Upper Silesian Coal Basin (USCB) and Legnica-Glogow Copper District (LGCD) area. Using the author's procedure for the assessment of the dynamic resistance, for each of the extortion analysed, the structure's response to the dynamic excitation was compared with the effects of load combinations adopted at the design stage, thus establishing the limit values of the design horizontal ground acceleration αmaxg,H understood as the structure's resistance to tremors. This allowed to assess the impact of seismic activity from a specific area on the dynamic resistance of the subjected object. The article also discusses the way of interpretation and the scope of application of the obtained results and proposed procedure.
W pracy przedstawiono wyniki badań dotyczących oceny odporności dynamicznej istniejących konstrukcji hal przemysłowych zlokalizowanych na terenach o różnej aktywności sejsmicznej. Podstawą do analiz była trójnawowa hala przemysłowa o konstrukcji stalowej. Przeprowadzono obliczenia numeryczne metodą elementów skończonych (MES), wykorzystując w analizie dynamicznej metodę spektrum odpowiedzi. Obliczenia przeprowadzono wariantowo, stosując wzorcowe przyspieszeniowe spektra odpowiedzi według Eurokodu 8 oraz te, wyznaczone dla obszaru Górnośląskiego Zagłębia Węglowego (GZW) i Legnicko-Głogowskiego Okręgu Miedziowego (LGOM). Stosując autorską procedurę oceny odporności dynamicznej, dla każdego analizowanego wymuszenia porównano reakcję konstrukcji na wzbudzenie dynamiczne z efektami od kombinacji obciążeń przyjętych na etapie projektowania, ustalając tym samym wartości graniczne projektowego przyspieszenia poziomego gruntu αmaxg,H rozumianego jako odporność konstrukcji na wstrząsy. Pozwoliło to na ocenę wpływu warunków sejsmicznych z określonego obszaru na odporność dynamiczną badanego obiektu. W artykule przedstawiono sposób interpretacji zaproponowanej procedury i wskazano potencjalne możliwości jej zastosowania.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 525-542
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analytical study on dynamic response of cantilever flexible retaining wall
Autorzy:
Yang, Xiuzhu
Liu, Xinyuan
Zhao, Shuang
Yu, Jun
Powiązania:
https://bibliotekanauki.pl/articles/27312122.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
analiza sejsmiczna
ścianka wspornikowa
ściana elastyczna
ściana oporowa
mechanika falowa
odpowiedź dynamiczna
rozwiązanie analityczne
seismic analysis
cantilever wall
flexible wall
retaining wall
wave mechanics
dynamic response
analytic solution
Opis:
Based on wave mechanics theory, the dynamic response characteristics of cantilever flexible wall in two-dimensional site are analyzed. The partial derivative of the vibration equation of soil layer is obtained, and the general solution of the volume strain is obtained by the separation of variables method. The obtained solution is substituted back to the soil layer vibration equation to obtain the displacement vibration general solution. Combined with the soil-wall boundary condition and the orthogonality of the trigonometric function, the definite solution of the vibration equation is obtained. The correctness of the solution is verified by comparing the obtained solution with the existing simplified solution and the solution of rigid retaining wall, and the applicable conditions of each simplified solution are pointed out. Through parameter analysis, it is shown that when the excitation frequency is low, the earth pressure on the wall is greatly affected by the soil near the wall. When the excitation frequency is high, the influence of the far-field soil on the earth pressure of the wall gradually increases. The relative stiffness of the wall, the excitation frequency and the soil layer damping factor have a significant effect on the dynamic response of the flexible retaining wall.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 435--453
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic behavior of a high-rise building under seismic loads for different bearing frame types
Dynamiczne zachowanie się budynku wysokiego pod obciążeniem sejsmicznym dla różnych typów szkieletu budynku
Autorzy:
Sakharov, V.
Lytvyn, O.
Pidlutskyi, V.
Powiązania:
https://bibliotekanauki.pl/articles/395785.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
bearing frame
girder frame
dynamic response
seismic load
modal analysis
numerical methods
soil base
foundation
high-rise building
rama nośna budynku
konstrukcja szkieletowa
odpowiedź dynamiczna
obciążenie sejsmiczne
analiza modalna
metody numeryczne
podłoże gruntowe
fundament
budynek wysoki
Opis:
Paper presents the results of dynamic behavior analysis of a high-rise building under seismic loads as part of the “base-foundation-building” system. Analysis covers different types of reinforced concrete construction with girder frame and non-girder frame. Using modal analysis, paper presents differences in mode shapes and frequencies caused by the presence or absence of girders. Paper also demonstrates variations in the stress-strain state for the vertical bearing structures under the seismic load for different frame types.
W artykule zostały przedstawione wyniki analizy dynamicznej zachowania się wielokondygnacyjnego budynku wysokiego pod obciążeniem sejsmicznym jako układu "podłoże gruntowe – fundament – budynek". Analiza obejmuje różne rodzaje konstrukcji szkieletowych z betonu zbrojonego o ramie nośnej z belkami wzmocnienia i bez nich. Wykorzystując analizę modalną, w artykule podane różnice we własnych formach i częstotliwościach dla różnych rodzajów szkieletu budynku. W prace również zostały wykazane zmiany w rozkładzie naprężeń w pionowych konstrukcjach nośnych budynku pod obciążeniem sejsmicznym w zależności od rodzaju szkieletu budynku.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(4); 180-189
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies