Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "scanning electron microscopy SEM" wg kryterium: Temat


Tytuł:
Nanopores with controlled profiles in track - etched membranes
Autorzy:
Sartowska, B. A.
Powiązania:
https://bibliotekanauki.pl/articles/146896.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
nanopore
scanning electron microscopy (SEM)
surfactant
track-etched membranes (TMs)
Opis:
Track-etched membranes are porous systems consisting of a polymer foil with thin channels-pores - from surface to surface. The increasing interest in this kind of material is connected with the development of nanoporous materials with unique properties such as diode-like effects in membranes with highly asymmetrical nanopores. The materials can be used for molecular sensors and atom beam optics, development of nanocapillary bodies for modelling the transport of molecules and ions in constrained volumes. Control over pore geometry opens the way to a number of new applications of track-etch membranes (TMs). The nanopores were obtained by the ion-track etching method using surfactant-doped alkaline solutions. Control over the pore profile and dimensions was achieved by varying the alkali concentration in the etchant and the etching time. The pore geometry was characterized in detail using field-emission scanning electron microscopy (SEM). SEM images of the surfaces and cleavages of TMs with different pore morphology are shown.
Źródło:
Nukleonika; 2012, 57, 4; 575-579
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties of Ni-Fe-Cu-P-B alloy produced by two component melt spinning (TCMS)
Autorzy:
Wojciechowska, M.
Ziewiec, K.
Kąc, S.
Prusik, K.
Powiązania:
https://bibliotekanauki.pl/articles/351728.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metallic glasses
scanning electron microscopy (SEM)
nanoindentation
transmission electron microscopy TEM
mechanical properties
Opis:
The aim of this work was to investigate the microstructure and mechanical properties of the two-component melt-spun (TCMS) alloy produced from Ni40Fe40B20 and Ni70Cu10P20 melts. The Ni40Fe40B20, Ni70Cu10P20, Ni55 Fe20 Cu5 P10 B10 alloys were arc-melted. Then the alloys were melt-spun in the two different ways i.e.: by casting from a single-chamber crucible and from the two-chamber crucible. All of the above mentioned alloys were processed in the first way and the Ni40Fe40B20 and Ni70Cu10P20 were simultaneously cast on the copper roller from the two-chamber crucible. The microstructure of the alloy was studied using transmission electron microscopy (TEM), scanning electron microscopy (SEM) with energy dispersive spectrometry (EDS) and light microscopy. The mechanical properties were investigated using tensile testing and nanoindentation. The two-component melt-spun (TCMS) amorphous Ni55 Fe20 Cu5 P10 B10 alloy present hardness, tensile strength and Young modulus on the significantly higher level than for a single phase amorphous Ni55 Fe20 Cu5 P10 B10 alloy and slightly below the corresponding values for the Ni40Fe40B20.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 137-140
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diatomaceous rocks of the Jawornik deposit (the Polish Outer Carpathians): petrophysical and petrographical evaluation
Autorzy:
Figarska-Warchoł, B.
Stańczak, G.
Rembiś, M.
Toboła, T.
Powiązania:
https://bibliotekanauki.pl/articles/184292.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
critical raw materials
diatomite
silica
scanning electron microscopy (SEM)
chemical analysis
porosity
Vickers microindentation hardness
Opis:
Diatomites belonging to a list of raw materials used in the EU criticality assessment are essential to many industrial applications due to a unique combination of their physical properties, i.e. porous and permeable structure, high specific surface area and adsorption capacity, low density and thermal conductivity, and chemical inertness. The present study was undertaken to analyse the relationships between the pore network characteristics, petrophysical parameters, and mineralogical variability of the Lower Miocene diatomites from the Jawornik deposit (Skole Unit, the Polish Outer Carpathians, SE Poland). Five varieties of the diatomites, distinguished on the basis of the macroscopic features, i.e., colour and fracturing effects, have been investigated by SEM, chemical and XRD analysis, mercury intrusion porosimetry, helium pycnometry, and the Vickers hardness tests. Significantly differing are two varieties. The light-coloured, massive and block-forming diatomites (variety BL) consist mainly of poorly cemented siliceous skeletal remains of diatoms, and represent the rocks with high total porosity (38–43%), low bulk density (1.28–1.38 g/cm3) and low microhardness (10.7 HV0.3). The dark-gray silicified diatomites with a platy or prismatic splitting (variety PD) reveal obscured microfossils of diatoms and are the most compact and hard rocks (80.8 HV0.3), with poor total porosity (17–24%) and higher bulk density (1.70–1.78 g/cm3). The spatial distribution of the field identifiable rock varieties allows selective exploitation of the diatomites with the predictable petrophysical characteristics that define their future use.
Źródło:
Geology, Geophysics and Environment; 2015, 41, 4; 311-331
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena wpływu zewnętrznych pól magnetycznych i elektromagnetycznych na działanie skaningowego mikroskopu elektronowego
Estimation of external magnetic and electromagnetic fields influence on Scanning Electron Microscope operation
Autorzy:
Płuska, M.
Oskwarek, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/151432.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikroskopia elektronowa
skaningowy mikroskop elektronowy
zakłócenia elektromagnetyczne
indukcja magnetyczna
scanning electron microscopy (SEM)
electromagnetic distortions
magnetic induction
Opis:
Tematyka artykułu odnosi się do aktualnych zagadnień z zakresu skanin-gowej mikroskopii elektronowej. Odkształcenia obrazu struktury badanego obiektu spowodowane wpływem zewnętrznych pól magnetycznych lub elektromagnetycznych są jednym z najczęstszej spotykanych niepożądanych efektów w mikroskopii. Prowadzone w tym zakresie analizy i badania mają na celu przede wszystkim uzyskanie oceny ilościowej dotyczącej indukcji pola magnetycznego przenikającego przez komorę mikroskopu oraz jej wpływu na wartość odchylenia wiązki padającej na obiekt badany (np. element półprzewodnikowy).
In the paper some tasks deal with Scanning Electron Microscope (SEM) are presented. Image deformation caused by electromagnetic interference (EMI) is one of the most frequent undesirable effects in practical scanning electron microscopy. They usually appear as a constant or periodic deformation of vertical edges of an observed specimen. Available, but still very expensive methods for decreasing their influence are shielding and electromagnetic field compensation. The other approach is digital image processing for its correction. However, elimination of the distortions (with hardware or software methods) would be more effective when their influence on microscope system are known or predictable. The main goal of current investigations is work out a method for quantitative measurement of magnetic field in the microscope chamber and estimation of its influence on electon beam deflaction. The results obtained by the use of scanning electron microscope were verified by comparing its with the ones obtained using alternative magnetic field meter.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9, 9; 61-64
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence condition of electro-spark alloying by Al and sequent laser treatment on surface layer of steel GradeB A284
Autorzy:
Smolina, I.
Franchik, N.
Lobachova, G.
Powiązania:
https://bibliotekanauki.pl/articles/115562.pdf
Data publikacji:
2011
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
electro-spark alloying (ESA)
laser treatment (LT)
steel GradeB A284
surface layer
hardened surface
microhardness
scanning electron microscopy (SEM)
Opis:
In the present paper structure and properties of alloying by aluminum surface layer of steel GradeB A284, which were obtain by electro-spark alloying (ESA) and sequent laser treatment (LT) are described. The properties of coatings were investigated by SEM and X-ray diff raction, microstructure and microhardness analysis. It has been shown that next laser treatment can increase the depth of hardened layer doped with 50 to 80…100 μm, but in comparison with ESA, reduces the value of microhardness from 10 to 5 GPa.
Źródło:
Challenges of Modern Technology; 2011, 2, 3; 25-28
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka fotoutwardzalnych żywic akrylowych do zastosowań w przemyśle drzewnym
Characteristics of photocurable acrylic resins for use in wood industry
Autorzy:
Jurczyk-Kowalska, Magdalena
Płocińska, Magdalena
Choińska, Emilia
Zagórski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/947137.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
polimery akrylowe
właściwości termiczne
skaningowa mikroskopia elektronowa SEM
lepkość
utwardzanie promieniowaniem UV
acrylic polymers
thermal properties
scanning electron microscopy SEM
viscosity
UV-curing
Opis:
Fotoutwardzalne polimery na bazie żywic akrylowych stanowią szeroką grupę materiałów o złożonej budowie chemicznej. Z zastosowaniem spektroskopii w podczerwieni (IR) scharakteryzowano żywice pochodzące od trzech czołowych producentów materiałów polimerowych stosowanych w przemyśle drzewnym: AkzoNobel, Klumpp oraz Kneho-Lacke. W otrzymanych widmach stwierdzono obecność pasm charakterystycznych zarówno dla struktury akrylanów, jak i epoksydów. Analiza mikrostruktury pozwoliła na stwierdzenie obecności w strukturze badanych żywic znacznej ilości napełniaczy. Wykazano, że żywica firmy AkzoNobel, charakteryzująca się najmniejszą lepkością, stabilnością termiczną oraz najsłabszymi właściwościami adhezyjnymi i twardością, zawiera najwięcej cząstek napełniaczy. Natomiast żywica firmy Klumpp wykazywała najmniejszą podatność na zmienne warunki sieciowania, co przejawiało się jej najlepszymi właściwościami adhezyjnymi. Stwierdzono też, że na właściwości termiczne i mechaniczne żywic w większym stopniu wpływa budowa chemiczna niż ilość zastosowanych napełniaczy.
The UV light cured polymeric materials, based on acrylic monomers, constitute a wide group of products with a complex chemical structure. The resins obtained from three leading manufacturers of polymeric materials used in wood industry: AkzoNobel, Klumpp and Kneho-Lacke were investigated. The chemical structure of the resins was characterized by infrared spectroscopy (IR). The obtained spectra revealed the presence of absorption bands which are characteristic for the structure of acrylates as well as epoxides. The analysis of microstructure indicated the presence of significant amounts of fillers in the structure of tested resins. Our study showed that the AkzoNobel resin, characterized by the lowest viscosity, thermal stability, adhesion properties and hardness, contained the most amount of filler particles. The Klumpp resin was least susceptible to changes in the crosslinking conditions and showed the best adhesive properties. It was found, that the chemical structure influences the thermal and mechanical properties of the resins to a larger extent than the filler content.
Źródło:
Polimery; 2019, 64, 5; 340-347
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The origin and chronology of medieval silver coins based on the analysis of chemical composition
Autorzy:
Pańczyk, E.
Sartowska, B.
Waliś, L.
Dudek, J.
Weker, W.
Widawski, M.
Powiązania:
https://bibliotekanauki.pl/articles/147506.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
elemental composition
medieval Central Europe coins
scanning electron microscopy (SEM)
laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)
numismatists
Opis:
Medieval Central Europe coins – the Saxon coins, also called as the Otto and Adelheid denarii, as well as the Polish ones, the Władysław Herman and Bolesław Śmiały coins – were examined to determine their provenance and dating. Their attribution and chronology often constitute a serious problem for historians and numismatists. For hundreds of years, coins were in uncontrolled conditions and in variable environment. Destructed and inhomogeneous surface were the effect of corrosion processes. Electron microscopy with energy dispersive X-ray analysis (scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS)), X-ray fluorescence (XRF) analysis (energy dispersive X-ray fluorescence (EDXRF) and total reflection X-ray fluorescence (TXRF)), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) were applied. The results of these investigations are significant for our knowledge of the history of Central European coinage, especially of Polish coinage.
Źródło:
Nukleonika; 2015, 60, No. 3, part 2; 657-663
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atomic force microscopy investigation of electron beam (EB) irradiated composites based on biodegradable polymers and coconut fiber*
Autorzy:
Kodama, Y.
Oishi, A.
Nagasawa, N.
Nakayama, K.
Tamada, M.
Machado, L. D. B.
Powiązania:
https://bibliotekanauki.pl/articles/147470.pdf
Data publikacji:
2013
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
atomic force microscopy (AFM)
coconut fiber
electron beam (EB) radiation
force modulation microscopy (FMM)
poly(ε-caprolactone) (PCL)
poly(L-lactic acid) (PLLA)
scanning electron microscopy (SEM)
Opis:
In this study, the addition of natural fibers to biodegradable PCL, PLLA blend and the effect of ionizing radiation on the surface of composites were investigated by force modulation microscopy (FMM), atomic force microscopy (AFM) and scanning electron microscopy (SEM). Hot pressed sheets were prepared using pellets of twin extruded PCL:PLLA 20:80 (w:w) blend containing 5% or 10% weight concentration of coconut fiber. In this study coconut fibers non treated chemically and acetylated ones were used. Irradiation was performed using an electron beam (EB) accelerator and an absorbed dose of 100 kGy. FMM images acquisition was obtained using a silicon cantilever, intermittent contact mode (tapping mode). Also, AFM images were obtained using tapping mode but J scanner. By FMM, it was possible to observe regions with different elasticity indicating fiber presence under the surface of the composite. Furthermore, it appears that the spherical structures size decreased on composites. This probably was induced by ionizing radiation.
Źródło:
Nukleonika; 2013, 58, 4; 459-468
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructure and mechanical properties of amorphous/crystalline ductile liquid immiscible Fe-Si-B-In alloy produced by two-component melt-spinning
Mikrostruktura i właściwości mechaniczne ciągliwego stopu amorficzno-krystalicznego na osnowie Fe-Si-B-In wytworzonego przez odlewanie na wirujący walec z tygla dzielonego
Autorzy:
Ziewiec, K.
Wojciechowska, M.
Mucha, D.
Ziewiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/263767.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
metallic glasses
X-ray diffraction (XRD)
scanning electron microscopy SEM
tensile test
ductility
szkła metaliczne
dyfrakcja rentgenowska
skaningowa mikroskopia elektronowa
statyczna próba rozciągania
ciągliwość
Opis:
The two-component melt-spun (TCMS) Fe71.25Si9.5B14.25In5 alloy was produced from Fe75Si10B15 and Fe67.5Si9B13.5In10 alloys. The microstructure of the TCMS alloy was investigated by means of scanning electron microscopy (SEM) and X-ray diffraction (XRD). A tensile test of the alloy resulted in a tensile strength of Rm = 1040 MPa, yield strength Re= 919 MPa, total plastic elongation ɛtot = 3.29%, and traces of plastic deformation on the surface of the Fe-Si-B-In TCMS sample. Microstructural analysis of the amorphous/crystalline composite and tensile sample free surface show the reason for the ductility of the sample in relation to the Fe75Si10B15 alloy.
Stop Fe71,25Si9,5B14,25In5 wytworzono w wyniku odlewania z tygla dzielonego na wirujący walec miedziany dwóch stopów (metoda TCMS): Fe75Si10B15 i Fe67,5Si9B13,5In10. Mikrostrukturę stopu TCMS badano za pomocą skaningowego mikroskopu elektronowego oraz dyfraktometru rentgenowskiego. Z przeprowadzonej statycznej próby rozciągania uzyskano wytrzymałość na rozciąganie stopu Rm= 1040 MPa, granicę plastyczności Re= 919 MPa, wydłużenie całkowite εtot = 3,29 %. Na powierzchni próbki stopu Fe-Si-B-In TCMS po zerwaniu zaobserwowano także ślady odkształcenia plastycznego. Analiza mikrostruktury otrzymanego amorficzno-krystalicznego kompozytu oraz powierzchni swobodnej próbki wyjaśniają przyczynę ciągliwości próbki w stosunku do stopu Fe75Si10B15.
Źródło:
Metallurgy and Foundry Engineering; 2017, 43, 1; 57-66
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physicochemical and electrochemical properties of AISI 316L stainless steel used for implants in human urinary system
Ocena własności fizykochemicznych i elektrochemicznych stali AISI 316L stosowanej na implanty w urologii
Autorzy:
Walke, W.
Przondziono, J.
Powiązania:
https://bibliotekanauki.pl/articles/351228.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
AISI 316L stainless steel
electrochemical impedance spectroscopy (EIS)
X-ray photoelectron spectroscopy (XPS)
scanning electron microscopy (SEM)
austenityczna stal nierdzewna AISI 316L
elektrochemiczna spektroskopia impedancyjna EIS
rentgenowska spektroskopia fotoelektronów XPS
skaningowa mikroskopia elektronowa (SEM)
Opis:
The main purpose of this study was to evaluate physicochemical and electrochemical properties of AISI 316L stainless steel with modified surface, used for implants in human urinary system. In order to simulate conditions, which occur in the tissue environment of the urinary system, the test pieces were exposed in a urinary solution at temperature of T=37 ±1ºC, for a period of 30 days. Evaluation of physicochemical properties of biomaterial was made on the basis of surface chemical analysis (XPS). To evaluate the effects which occur on the surface of the examined steel, Electrochemical Impedance Spectroscopy (EIS) method was also employed. Analysis of test results shows favourable influence of the suggested surface treatment of AISI 316L stainless steel. Samples having electrolytically polished and chemically passivated surface featured the best physicochemical and electrochemical characteristics.
Podstawowym kryterium przydatności biomateriału metalowego na implanty urologiczne (stenty urologiczne) jest biokompatybilność. Jest ona w głównej mierze związana z własnościami fizykochemicznymi powierzchni implantu, które powinny być dostosowane do cech środowiska tkanek układu moczowego człowieka. W celu poprawy biokompatybilności stali Cr-Ni-Mo ustalono warunki wytwarzania warstw pasywnych na jej powierzchni. Wytworzenie warstwy pasywnej obejmowało etap polerowania elektrolitycznego i pasywowania. Taki sposób obróbki powierzchniowej zapewnił chropowatość Ra < 0,16 μm wymaganą dla tego rodzaju implantów. W pracy tej szczególną uwagę skoncentrowano na analizie długotrwałego oddziaływania środowiska sztucznego moczu na własności fizykochemiczne wytypowanej stali. Zasadniczym celem pracy była ocena własnosci fizykochemicznych i elektrochemicznych stali AISI 316L o modyfikowanej powierzchni stosowanej na implanty w układzie moczowym człowieka. W celu zasymulowania warunków występujących w środowisku tkankowym układu moczowego próbki poddawano ekspozycji w roztworze sztucznego moczu o temperaturze T=37±1ºC przez okres 30 dni. O przydatności zaproponowanej warstwy pasywnej do uszlachetniania powierzchni stali w znacznym stopniu decyduje jej skład chemiczny. Dlatego w pracy wykonano badania składu chemicznego metodą spektroskopii fotoelektronów (XPS), z użyciem wielofunkcyjnego spektrometru elektronów PHI 5700/660 firmy Physical Electronics, podczas których zidentyfikowano i wyznaczono stężenia atomowe pierwiastków w badanych warstwach pasywnych. Dla próbek przeprowadzono pomiar widma fotoelektronów w szerokim zakresie energii wiązania od 0÷1400 eV oraz dokładne pomiary linii widmowych poszczególnych pierwiastków składowych z warstwy powierzchniowej. Dla oceny zjawisk zachodzacych na powierzchni badanej stali zastosowano również metodę elektrochemicznej spektroskopii impedancyjnej (EIS). Pomiary przeprowadzono z wykorzystaniem systemu pomiarowego AutoLab PGSTAT 302N wyposażonego w moduł FRA2 (Frequency Response Analyser). Badania przeprowadzono w alternatywnym roztworze symulującym środowisko moczu człowieka. Zastosowana w pracy mikroskopia skaningowa pozwoliła na ocene stanu powierzchni stali AISI 316L przed i po ekspozycji w sztucznym moczu. Analiza wyników badań wskazuje na korzystny wpływ zaproponowanej obróbki powierzchniowej stali AISI 316L. Najkorzystniejszą charakterystykę fizykochemiczną i elektrochemiczną miały próbki o powierzchni polerowanej elektrolitycznie i pasywowanej chemicznie. Przeprowadzone w pracy badania stanowią podstawę do dalszych analiz związanych z zagadnieniem biokompatybilności stali Cr-Ni-Mo stosowanej na implanty w urologii.
Źródło:
Archives of Metallurgy and Materials; 2013, 58, 2; 625-630
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Failure Strain and Strain-Stress Analysis in Titanium Nitride Coatings Deposited on Religa Heart Ext Ventricular Assist Device
Odkształcenie uszkodzenia i analiza odkształceniowo-naprężeniowa w powłokach azotku tytanu nanoszonych na komorę wspomagania pracy serca Religa Heart Ext
Autorzy:
Kopernik, M.
Powiązania:
https://bibliotekanauki.pl/articles/356873.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
titanium nitride (TiN)
left ventricular assist device
finite element method (FEM)
scanning electron microscopy (SEM)
micro-tensile test
azotek tytanu (TiN)
urządzenie wspomagania lewej komory (VAD)
metoda elementów skończonych
skaningowy mikroskop elektronowy
Opis:
The Polish ventricular assist device is made of Bionate II with deposited TiN biocompatible nano-coating. The two scale finite element model is composed of a macro-model of blood chamber and a micro-model of the TiN/Bionate II. The numerical analysis of stress and strain states confirmed the possibility of fracture. Therefore, the identification of a fracture parameter considered as a failure strain is the purpose of the present work. The tensile test in a micro chamber of the SEM was performed to calibrate the fracture parameter of the material system TiN/Bionate II. The failure strain is a function of a temperature, a thickness of coating and parameters of surface's profile. The failure strain was calculated at the stage of the test, in which the initiation of fracture occurred. The finite element micro-model includes the surface roughness and the failure strain under tension condition for two thicknesses of coatings which will be deposited on the medical device.
Polska komora wspomagania pracy serca jest wykonana z Bionate II z naniesioną biokompatybilną powłoką TiN. Dwu-skalowy model elementów skończonych składa się z modelu makro czaszy krwistej i z modelu mikro dla TiN/Bionate II. Numeryczna analiza stanów naprężeń i odkształceń potwierdza prawdopodobieństwo pękania. Zatem, identyfikacja parametru pękania rozpatrywanego jako odkształcenie uszkodzenia jest celem niniejszej pracy. Próba rozciągania w komorze SEM została przeprowadzona, aby skalibrować parametr pękania dla układu materiałowego TiN/Bionate II. Odkształcenie uszkodzenia jest funkcją temperatury, grubości powłoki i parametrów profilu powierzchni. Odkształcenie uszkodzenia zostało obliczone w tym etapie testu, w którym pojawiła się inicjacja pęknięcia. Mikro model elementów skończonych zawiera chropowatość powierzchni i odkształcenie uszkodzenia w warunkach rozciągania dla dwóch grubości powłok, które będą nanoszone w tym urządzeniu medycznym.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 1; 121-129
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tribological tests of the nanomaterials used to reconstruct molars and premolars with the application of the direct method
Badania tribologiczne nanomateriałów do odbudowy zębów trzonowych i przedtrzonowych metodą bezpośrednią
Autorzy:
Ryniewicz, W.
Herman, M.
Ryniewicz, A. M.
Bojko, Ł.
Pałka, P.
Ryniewicz, A.
Madej, T.
Powiązania:
https://bibliotekanauki.pl/articles/190528.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stomatognathic system
composite
friction
wear
SEM (scanning electron microscopy)
nanostructure
układ stomatognatyczny
kompozyt
tarcie
zużycie
SEM
nanostruktura
Opis:
Physiological abrasion of teeth is a process of gradual loss of the hard tissue of opposite teeth resulting from age-related natural dental wear. In abrasion, the cusps and their slopes in the jaw and the mandible become flattened due to the mechanical load applied. The aim of this paper is to carry out a tribological and microstructural evaluation of modern composite materials used to reconstruct the teeth in the lateral part of the dental arch. Five light-cured composite materials were selected for tests. The tests involved the coefficient of friction and resistance to wear in a sliding contact in the presence of artificial saliva and the microstructure of the external surface of samples before the wear process and in the wear-related damaged area. The test method applied, which combines a biomechanical analysis of resistance to wear and the analysis of the microstructure before the wear process and in the wear-related damaged area, makes it possible to evaluate the tribological properties of composite materials used to reconstruct teeth in the lateral part of the dental arch.
Fizjologiczne starcie zębów jest to proces stopniowej utraty twardych tkanek zębów przeciwstawnych w wyniku naturalnego zużycia postępującego z wiekiem. Starcie to polega na jednoczesnym spłaszczaniu guzków i ich stoków w zębach szczęki i żuchwy w warunkach obciążeń biomechanicznych. Celem pracy jest ocena tribologiczna i mikrostrukturalna nowoczesnych materiałów kompozytowych stosowanych do odbudowy ubytków w bocznym odcinku łuku zębowego. Do badań wybrano 5 materiałów kompozytowych utwardzanych światłem. Przeprowadzono badania współczynnika tarcia i odporności na zużycie w kontakcie ślizgowym, w obecności sztucznej śliny oraz badania mikrostrukturalne warstwy wierzchniej próbek przed procesem zużycia oraz w strefie skazy zużyciowej. Zastosowana metoda badań łącząca biomechaniczną analizę odporności na zużycie z analizą mikrostruktury przed procesem zużycia oraz w skazie zużyciowej pozwala na ocenę właściwości tribologicznych materiałów kompozytowych do odbudowy zębów w bocznym odcinku łuku.
Źródło:
Tribologia; 2017, 273, 3; 155-164
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of the cause of the stem neck fracture in the hip joint endoprosthesis
Autorzy:
Ryniewicz, A. M.
Bojko, Ł.
Ryniewicz, A.
Pałka, P.
Ryniewicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/265412.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
proteza plastyczna
złamanie zmęczeniowe
metoda elementów skończonych
skaningowa mikroskopia elektronowa
prosthetic arthroplasty
stem construction
fatigue fracture
FEM
SEM (scanning electron microscopy)
Opis:
Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides) that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.
Źródło:
International Journal of Applied Mechanics and Engineering; 2018, 23, 1; 223-234
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
X-ray techniques in the investigation of a Gothic sculpture : the risen Christ
Autorzy:
Mikołajska, A.
Walczak, M.
Kaszowska, Z.
Urbańczyk-Zawadzka, M.
Powiązania:
https://bibliotekanauki.pl/articles/146866.pdf
Data publikacji:
2012
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cultural heritage
X-ray image
X-ray dual source computed tomography (DSCT)
scanning electron microscopy energy dispersed X-ray spectroscopy (SEM-EDX)
Opis:
For over a century, X-ray radiation has played an important role in the area of the conservation and restoration of cultural heritage objects. X-ray techniques are amongst the most fundamental and helpful methods used in the investigation of art works. This paper reviews the application of traditional radiography, X-ray dual source computed tomography (DSCT) and scanning electron microscopy combined with energy dispersed X-ray spectroscopy (SEM-EDX) to the investigation of a wooden, Gothic sculpture, The risen Christ. Thanks to the properties of X-ray radiation (different absorption by various materials) first two methods allow the assessment of the preservation state and the observation of the internal structure of an object in 3-D. While SEM-EDX analysis permits the elemental analysis of the polychrome layers. As a result 2-D and 3-D images, permitting the full volume inspection of an object, were taken in a totally non-destructive way. The morphological and physical information about the inner structure of the investigated wooden sculpture was obtained, revealing changes related to previous restorations, as well as ageing effects. Employing the SEM-EDX, painting materials (pigments and filers), were identified. Gained data is essential for restorers to understand the whole structure of the studied object and to decide which further investigation and restoration steps have to be undertaken.
Źródło:
Nukleonika; 2012, 57, 4; 627-631
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza SEM czarnego tonera na wydrukach. Część I
SEM analysis of black toners on printouts. Part I
Autorzy:
Łasińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/501609.pdf
Data publikacji:
2019-11-29
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
toner
Canon
Dell
Epson
Ricoh
skaningowa mikroskopia elektronowa
SEM
toners
scanning electron microscopy
Opis:
W publikacji przedstawiono wyniki analizy struktury powierzchni czarnych tonerów na wydrukach, dokonanej za pomocą skaningowego mikroskopu elektronowego. Przeprowadzono testy tonerów z kilku wydruków pochodzących z 18-laserowych urządzeń drukujących czterech firm: Canon, Dell, Epson i Ricoh. Wdrożenie skaningowej mikroskopii elektronowej do kryminalistycznych badań dokumentów stworzyło nowe możliwości identyfikacji laserowych urządzeń drukujących. Uzyskane obrazy mikroskopowe pozwoliły na przyporządkowanie charakterystycznych cech tonerów do poszczególnych grup urządzeń.
black toners commercialized in Poland. A total of eighteen printouts of Canon, Dell, Epson and Ricoh manufacturer was analyzed. The analysis showed that the implementation of a much more sensitive method, such as the scanning electron microscopy (SEM) provided new opportunities for the identification of laser printing. The microscopic images obtained allowed us to allocate the characteristic features of toners to specific groups of devices.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2019, 11, 21; 211-246
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
SEM analysis of black toners on printouts. Part I
Analiza SEM czarnego tonera na wydrukach. Część I
Autorzy:
Łasińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/501627.pdf
Data publikacji:
2019-11-29
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
toners
Canon
Dell
Epson
Ricoh
scanning electron microscopy
SEM
toner
skaningowa mikroskopia elektronowa
Opis:
This paper describes the use of scanning electron microscopy in the analysis of original black toners commercialized in Poland. A total of eighteen printouts of Canon, Dell, Epson and Ricoh manufacturer was analyzed. The analysis showed that the implementation of a much more sensitive method, such as the scanning electron microscopy (SEM) provided new opportunities for the identification of laser printing. The microscopic images obtained allowed us to allocate the characteristic features of toners to specific groups of devices.
W publikacji przedstawiono wyniki analizy struktury powierzchni czarnych tonerów na wydrukach, dokonanej za pomocą skaningowego mikroskopu elektronowego. Przeprowadzono testy tonerów z kilku wydruków pochodzących z 18-laserowych urządzeń drukujących czterech firm: Canon, Dell, Epson i Ricoh. Wdrożenie skaningowej mikroskopii elektronowej do kryminalistycznych badań dokumentów stworzyło nowe możliwości identyfikacji laserowych urządzeń drukujących. Uzyskane obrazy mikroskopowe pozwoliły na przyporządkowanie charakterystycznych cech tonerów do poszczególnych grup urządzeń.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2019, 11, 21; 363-392
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ilościowa i jakościowa analiza mieszanin pirotechnicznych – SEM/EDS
Quantitatvie and qualitative analysis of pirotechnical mixtures – SEM/EDS
Autorzy:
Łasińska, Anna
Barszcz, Krystyna
Powiązania:
https://bibliotekanauki.pl/articles/501617.pdf
Data publikacji:
2014
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
Mieszaniny pirotechniczne
skaningowa mikroskopia elektronowa
SEM
mikroanaliza rentgenowska
EDS
Pyrotechnic mixtures
scanning electron microscopy
energy-dispersive spectrometry
SEM/EDS
Opis:
Rozwój techniki pozwala na tworzenie nowszych i doskonalszych sposobów identyfikacji śladów przestępstw. Przez samą naturę różnych przestępstw objętych dochodzeniem kryminalistycznym mikroskop elektronowy SEM/EDS musi zapewnić najwyższą wszechstronność i wydajność. Metoda ta pozwala jednocześnie na obserwację badanego obiektu przy dużych powiększeniach oraz oznaczenie jego składu pierwiastkowego. W publikacji zaprezentowano analizę powierzchni ziaren mieszanin pirotechnicznych za pomocą skaningowego mikroskopu elektronowego SEM. Na podstawie map rozkładu stężenia pierwiastków w wybranych obszarach skanowania podjęto próbę identyfikacji konkretnych związków chemicznych, które były użyte do sporządzenia mieszanin pirotechnicznych. Było to możliwe dzięki określeniu pewnych cech wspólnych widocznych na mapach, takich jak rozkład i intensywność zabarwienia. Metoda ta w pewnych przypadkach nie zawsze jednak dawała jednoznaczne wyniki. Wyraźne zróżnicowanie ilościowego udziału danego pierwiastka w mieszaninie w istotny sposób wpływało na wynik analizy EDS.
The development of technology allows to create newer and better ways to identify traces of crime. Due to the nature of the various crimes under forensic investigation, the electron microscope SEM / EDS must provide the very highest flexibility and performance. Our method allows the observation of the object at high magnifications while simultaneously indicating its elemental composition. We describe the use of the SEM scanning electron microscope to analyze the morphological surface of grains of pyrotechnic mixtures. Based on mapping the distribution of the concentration of elements in selected areas the scan attempts to identify specific chemical compounds used in the preparation of pyrotechnic mixtures. This was made possible by defining certain common features shown on the maps, such as the distribution and intensity of color. In certain situations, however, our method did not always produce unequivocal results. Significant differences in the proportion of a given element in the mixture significantly affected the outcome of the analysis using EDS.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2014, 6, 11; 177-205
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza SEM czarnego tonera na wydrukach. Część II
SEM analysis of black toner on printouts. Part II
Autorzy:
Łasińska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1052550.pdf
Data publikacji:
2021-04-29
Wydawca:
Agencja Bezpieczeństwa Wewnętrznego
Tematy:
toner
brother
konica minolta
skaningowa mikroskopia elektronowa
mikroanaliza rentgenowska
sem/edx
scanning electron microscopy
x-ray
microanalysis
Opis:
Eksperci w zakresie badań dokumentów są często proszeni o określenie, czy wydruk pochodzi z określonej drukarki laserowej. Drukarkę rzadko można zidentyfikować, chyba że na wydruku są widoczne jej unikalne wady lub nieprawidłowości. W artykule przedstawiono możliwości identyfikacji i weryfikacji tonerów na wydrukach uzyskanych z różnych drukarek laserowych przy użyciu skaningowej mikroskopii elektronowej. W sumie 21 wydruków uzyskano z 21 różnych modeli maszyn drukujących Brother i Konica Minolta. Szesnaście wydruków uzyskano z drukarek, w których były oryginalne kasety z tonerem, a pięć z drukarek z zamiennikami. Ustalono jasne kryteria oceny indywidualnej. Na podstawie zdjęć SEM oraz tych kryteriów ujawniono szczegóły topografii struktury tonera. Na podstawie przeprowadzonych badań określono różnice lub podobieństwa tonerów na badanych wydrukach.
Document examiners are frequently asked to determine whether or not a printout originated from a particular laser printer. The printer can rarely be identified unless some unique defects or irregularities of the printing are present on the printout. This article presents an overview of a systematic approach to characterizing and discriminating the toner of different laser printers using scanning electron microscopy. A total of twenty-one collected printouts were printed on twenty-one different Brother and Konica Minolta printing machine models. Sixteen printouts were obtained using printers with original toner cartridges while five printouts were obtained using printers with compatible cartridges. Clear criteria were established for individual assessment. Based on the SEM images and established criteria the details of topography of the toner structure were revealed. Due to this tudy, the differences or similarities of toners on tested printouts were determined. The SEM technique can be successfully, simply, and rapidly applied to the analysis of toners on paper documents.
Źródło:
Przegląd Bezpieczeństwa Wewnętrznego; 2021, 13, 24; 221-249
2080-1335
2720-0841
Pojawia się w:
Przegląd Bezpieczeństwa Wewnętrznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody mikroskopowe w ocenie procesów wykończania wyrobów włókienniczych
Evaluation of finishing processes for textile products using the microscopic methods
Autorzy:
Machnowski, Waldemar
Wrzosek, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/1818683.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Skórzanego
Tematy:
mikroskopia optyczna
SEM
skaningowa mikroskopia elektronowa
bawełna
jakość tekstyliów
procesy wykończenia tekstyliów
optical microscopy
scanning electron microscopy
cotton
textiles quality
textile finishing processes
Opis:
Badanie wyrobów włókienniczych odgrywa istotną rolę w systemie zapewnienia jakości tekstyliów, a także w pracach nad rozwojem nowych technologii i produktów włókienniczych. Istnieje wiele metod oceny struktury i właściwości włókien i wyrobów włókienniczych. Bardzo ważne miejsce wśród tych metod zajmują techniki mikroskopowe, w szczególności mikroskopia optyczna i skaningowa mikroskopia elektronowa (SEM). W artykule podano krótki przegląd możliwych zastosowań metod mikroskopowych do analizy efektów niektórych operacji wytwarzania tekstyliów. Wykorzystanie mikroskopu optycznego umożliwiło identyfikację przyczyn powodujących nierównomierność barwy wyrobów bawełnianych. Z przeglądu literatury oraz doświadczeń własnych autorów wynika, że metody mikroskopowe stanowią cenne narzędzie w badaniu włókien i wyrobów włókienniczych.
Fabric testing plays an important role in the quality assurance system and in the development of new textile technologies and products. There are many test methods used to evaluate the structure and properties of fibers and textile materials. Among these methods, microscopic techniques – especially optical microscopy and scanning electron microscopy (SEM) – are one of the most important methods. This paper provides a brief overview of the possible uses the microscopic methods for determining the results of some textile manufacturing processes. A review of the literature and the authors experiences in this field indicate that microscopic methods are a valuable tool for the testing and assessing the performance of fibers and textile products.
Źródło:
Technologia i Jakość Wyrobów; 2020, 65; 4--20
2299-7989
Pojawia się w:
Technologia i Jakość Wyrobów
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the Chemical Unhairing Process on Pulled Wool Characteristics
Autorzy:
Abdellaoui, Olfa
Harizi, Taoufik
Msahli, Slah
Powiązania:
https://bibliotekanauki.pl/articles/2171990.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
ATR-FTIR
red face Barbary sheep
sheep breed
chemical unhairing process
pulled wool
SEM
scanning electron microscopy
X-ray
Opis:
Textile research is being driven to find sustainable materials as an alternative to raw fibers. In fact, reusing fibrous waste, as a byproduct, is one of the most important environmental challenges that confront the world. This research focused on studying pulled wool fibers as a natural fiber to reduce environmental loading. There are large amounts of residual pulled wool fibers that can be recycled and valorised. Therefore, raw and pulled wool fibers were characterized and compared. Scanning Electron Micrographs (SEM) results show that on the pulled wool fiber, the surface became rougher and the scales appear affected and less dense. Based on the X-ray diffraction (XRD) results, the crystallinity of the pulled fiber decreased lightly. Attenuated Total Reflectance-Fourier Transform Infra Red (ATR-FTIR) spectroscopy analyzes presented some changes in chemical composition. A High-Performance Liquid Chromatography (HPLC) test showed an increase in the amount of cystic acids. The pulled wool fiber indicates that it might have damaged some crosslinks of macromolecular chains in the fiber. Thus, physical, chemical and mechanical properties are affected during the chemical unhairing process. This research purpose was to increase the potential for better value of pulled wool as it presents the natural fiber most used in several applications.
Źródło:
Fibres & Textiles in Eastern Europe; 2022, 3 (151); 70--78
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Engine-generated solid particles - a case study
Autorzy:
Szramowiat, K.
Woodburn, J.
Pacura, W.
Berent, K.
Bielaczyc, P.
Gołaś, J.
Powiązania:
https://bibliotekanauki.pl/articles/134094.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
engine emissions
particulate matter
nanoparticles
scanning electron microscopy
SEM
morphology
emisja spalin
cząstki stałe
nanocząstki
elektronowy mikroskop skaningowy
morfologia
Opis:
Current ecological trends and resulting legislation like European emissions standards Euro 6d or Best Available Techniques are setting new challenges in the field of environmental protection. Since the problem of emissions of particulate matter from diesel engines was solved by the application of diesel particulate filters (DPFs or FAPs) and due to the global dominance of gasoline fuelled passenger cars, particular concern has been focused on improvement of emissions performance of gasoline vehicles, including hybrids, as well as heavy-duty and non-road vehicles. This paper presents the results of preliminary studies on the chemical and physical properties of gasoline engine-generated particles, including nanoparticles. SEM images were presented which allowed identification of the character of particulate matter and estimates of the dimensions of particles. Moreover, the particles were found to be composed of different elements, including Cu, Si, Na, Ca, Zn and P, pointing to the origination of these particles from the pistons and lubricant additives.
Źródło:
Combustion Engines; 2018, 57, 3; 33-39
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Understanding technical cleanliness: importance, assessment, maintenance
Autorzy:
Faber, Joanna
Brodzik, Krzysztof
Nycz, Marta
Powiązania:
https://bibliotekanauki.pl/articles/2097549.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Naukowe Silników Spalinowych
Tematy:
technical cleanliness
component cleanliness code
contaminations
particles
optical microscopy
SEM
scanning electron microscopy
czystość techniczna
kod czystości komponentu
zanieczyszczenia
cząstki
mikroskopia optyczna
skaningowa mikroskopia elektronowa
Opis:
Development of the automotive industry, including so-called dowsizing and rightsizing, entails the need to ensure, and hence to verify, the stringent cleanliness levels of an increasing number of car components. The assurance of proper cleanliness level requires knowledge of the entire production process and precise information on the contaminants that will allow to identify their sources. Obtaining reliable cleanliness information requires establishing of many different factors, i. a. selection of proper contamination extraction and collection technique, proper parameters of extraction, validation of extraction procedure, methods of particles analysis. Analytical techniques which are implemented include gravimetric, optical microscopy and advanced techniques like scanning electron microscopy. This work present’s actual state of knowledge regarding technical cleanliness analysis of components. Important aspects of QA&QC in technical cleanliness assessment are also discussed.
Źródło:
Combustion Engines; 2021, 60, 3; 41--50
2300-9896
2658-1442
Pojawia się w:
Combustion Engines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The modern approach to manufacturing of carbon-rhenium nanocomposites
Autorzy:
Dobrzańska-Danikiewicz, A. D.
Wolany, W.
Powiązania:
https://bibliotekanauki.pl/articles/2201076.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
rhenium
MWCNTs
multiwall carbon nanotubes
nanocomposites
high-temperature method
SEM
scanning electron microscope
TEM
transmission electron microscopy
ren
wielościenne nanorurki węglowe
nanokompozyt
skaningowa mikroskopia elektronowa
transmisyjna mikroskopia elektronowa
Opis:
Purpose The aim of the paper is to present the high-temperature method of producing MWCNTs-Re nanocomposites, the selection of satisfactory production conditions and the presentation of the results of microscopic and spectroscopic studies of nanocomposites produced by this method. Design/methodology/approach Two methods of manufacturing carbon-rhenium nanocomposites were tested: ineffective chemical synthesis and high-temperature reduction using H2, which was proven successful and allowed the production of nanocomposites with the expected properties. The received nanocomposites were investigated using Transmission Electron Microscope (TEM), and Scanning Electron Microscope (SEM), as well as were subjected to spectroscopic examination. Findings The article presents three steps of MWCNTs-Re nanocomposites fabrication using the high-temperature method, functionalization, impregnation and reduction. As part of own work, satisfactory conditions for producing those nanocomposites using a materials science and heuristic analysis were selected. Research limitations/implications The proposed high-temperature method allows to join rhenium nanoparticles with MWCNTs permanently. It is reasonable to test in the future whether the method is also effective for other carbon nanomaterials and/or nanoparticles of other metals. Practical implications MWCNTs-Re nanocomposites can be used as sensors of gases that are harmful to the environment. It was also confirmed that the MWCNTs-Re_4 nanocomposite has catalytic properties. Originality/value The paper presents a modern approach to the manufacturing of MWCNTs-Re nanocomposites, which assumes the use of a high-temperature furnace to heat the material in a hydrogen atmosphere.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 115, 2; 57--63
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Employing various metallography methods at high temperature alloy fatigue tests evaluation
Autorzy:
Belan, J.
Kucharikova, L.
Vasko, A.
Chalupova, M.
Svecova, I.
Powiązania:
https://bibliotekanauki.pl/articles/111897.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
Ni-base casting and wrought alloys
gamma prime
gamma double prime
gamma solid solution
light microscopy
scanning electron microscopy
SEM
skaningowa mikroskopia elektronowa
stopy do obróbki plastycznej
mikrostruktury nadstopów
stop
odlew
Opis:
Microstructures of superalloys have dramatically changed throughout the years, as modern technology of its casting or forging has become more sophisticated. The first superalloys have polyedric microstructure consisting of gamma solid solution, some fraction of gamma prime and of course grain boundaries. As demands on higher performance of aero jet engine increases, the changes in superalloys micro-structure become more significant. A further step in microstructure evolution was directionally solidified alloys with columnar gamma prime particles. The latest microstructures are mostly monocrystalline, oriented in [001] direction of FCC gamma matrix. All microstructure changes bring necessity of proper preparation and evaluation of microstructure. Except for the already mentioned structures have gamma double prime and various carbides form can be seen. These structural parameters have mainly positive influence on important mechanical properties of superalloys. The paper deals with a microstructural evaluation of both groups of alloys – cast and as well as wrought. Micro-structure evaluation helps to describe mechanism at various loading and failure of progressive superalloys. Such an example where micro-structure evaluation is employed is fractography of failure surfaces after fatigue tests, which are examples of metallography evaluation de-scribed in this paper as a secondary objective.
Źródło:
Production Engineering Archives; 2016, 13, 4; 11-15
2353-5156
2353-7779
Pojawia się w:
Production Engineering Archives
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the friction pair load on tribological characteristics of polymer composites in reciprocating motion
Wpływ obciążenia węzła tarcia na charakterystyki tribologiczne kompozytów polimerowych w ruchu postępowo-zwrotnym
Autorzy:
Pawelec, Z.
Powiązania:
https://bibliotekanauki.pl/articles/188803.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
machine tools
guides
polymer composite
reciprocating motion
friction
wear
scanning electron microscopy
obrabiarki
układy prowadnicowe
kompozyt polimerowy
ruch postępowo-zwrotny
tarcie
zużycie
skaningowa mikroskopia elektronowa (SEM)
Opis:
This paper presents the influence of the friction pair load on the wear and friction coefficient of polymer composites in reciprocating motion. The tested polymer composites are used in regeneration purposes of supports in cutting tools. Tribological characteristics were evaluated for composites modified with graphite and molybdenum disulphide as the additives (modifiers). The tests were performed by the use of T-17 tribotester under conditions of various loads (100, 150, 200 N), with a frequency of 1 Hz, and the 20 000 cycles of 25 mm amplitude. The friction pairs were lubricated with standard machine oil. For comparison purposes, the tribological characteristics of steel-steel configuration were performed. The mechanism of friction pair wear was evaluated by the analysis with scanning electron microscopy (SEM). The results have show that the increase in the load of friction pair affects the friction coefficient Orly restrainedly. The polymer regeneration composites designed for flat guide rails in cutting machines proved to be more useful and resistant than the steel-steel combination.
W artykule przedstawiono wpływ obciążenia węzła tarcia na zużycie i współczynnik tarcia kompozytów polimerowych w ruchu postępowo-zwrotnym stosowanych do regeneracji suportów obrabiarek skrawających. Charakterystyki tribologiczne wyznaczono dla kompozytów z udziałem modyfikatorów tarcia grafitu i dwusiarczku molibdenu w układzie pojedynczym i binarnym. Badania przeprowadzono z użyciem testera T–17. Testy tribologiczne przeprowadzono w warunkach zmiennych obciążeń węzła tarcia 100, 150 i 200 N, typowych dla układów prowadnicowych obrabiarek, częstotliwość 1 Hz, amplituda 25 mm, liczba cykli 20 000, przy smarowaniu olejem maszynowym. Dla porównania w tych samych warunkach wyznaczono również charakterystyki tribologiczne skojarzenia stal–stal. Mechanizm zużywania pary trącej oceniono na podstawie obrazów powierzchni tarcia uzyskanych za pomocą skaningowego mikroskopu elektronowego (SEM). Na podstawie uzyskanych wyników badań tribologicznych stwierdzono, że zwiększenie obciążenia węzła tarcia w umiarkowanym stopniu wpływa na zmiany współczynnika tarcia i zużycie kompozytów polimerowych. Polimerowe kompozyty regeneracyjne przeznaczone do regeneracji płaskich prowadnic obrabiarek skrawających w przyjętych warunkach badań charakteryzują się lepszymi właściwościami tribologicznymi niż skojarzenie stal–stal.
Źródło:
Tribologia; 2016, 266, 2; 111-120
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies