Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "scaling factor" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Scaling of numbers in residue arithmetic with the flexible selection of scaling factor
Autorzy:
Ulman, Z.
Czyżak, M.
Smyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/376813.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
scaling technique
scaling factor
residue arithmetic
Residue Number System
RNS
Mixed-Radix System
MRS
Opis:
A scaling technique of numbers in residue arithmetic with the flexible selection of the scaling factor is presented. The required scaling factor can be selected from the set of moduli products of the Residue Number System (RNS) base. By permutation of moduli of the number system base it is possible to create many auxiliary Mixed-Radix Systems (MRS). They serve as the intermediate systems in the scaling process. All MRS's are associated with the given RNS with respect to the base, but they have different sets of weights. For the scaling factor value resulting from the requirements of the given signal processing algorithm, the suitable MRS can be chosen that allows to obtain the scaling result in most simple manner.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 76; 175-179
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A fuzzy controller with a real-time tuning algorithm and its application to a steam generator water level control
Autorzy:
Jung, C.
Kwon, K.
Powiązania:
https://bibliotekanauki.pl/articles/205893.pdf
Data publikacji:
1998
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
sterowanie rozmyte
sterownik z logikami rozmytymi
fuzzy controller
instantaneous system performance
scaling factor
self-tuning
steam generator
Opis:
It is nesessary to tune the fuzzy rules and the scalling factors in real-time control of a large scale system, the steam generator of a nuclear power plant, as it is related to safety and availability of the plant. A novel real-time tuning algorithm of fuzzy controller based on the scaling factors is proposed and applied to the steam generator water level control system of the nuclear power plant. The new real-time tuning algorithm adopts a variable reference tuning index for a good system tuning response and an instantaneous system fuzzy performance for scaling factor tuning. For the fuzzy steam generator controller, an image signal of feedwater flow error at low power is proposed and pressure compensation rules and a gain scheduler of feedwater temperature are designed also. The fuzzy controller of the steam generator water level is simulated by the proposed method. The simulation results show that the improved performance of the steam generator water level controller by the proposed method.
Źródło:
Control and Cybernetics; 1998, 27, 4; 545-564
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Psychometric properties of the Polish version of the Job-related Affective Well-being Scale
Autorzy:
Basińska, Beata A.
Gruszczyńska, Ewa
Schaufeli, Wilmar B.
Powiązania:
https://bibliotekanauki.pl/articles/2179014.pdf
Data publikacji:
2014-12-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
job-related affective well-being scale
arousal
circumplex of emotions
multidimensional scaling
confirmatory factor analysis
Opis:
Objectives: The aim of this study was to verify psychometric properties of the Polish version of the Job-related Affective Well-being Scale (JAWS). Specifically, theoretical 4-factor structure (based on the dimensions of pleasure and arousal) and reliability of the original - 20-item JAWS (van Katwyk et al., 2000) and the shortened - 12-item (Schaufeli and Van Rhenen, 2006) versions were tested. Material and Methods: Two independent samples were analyzed (police officers, N = 395, and police recruits, N = 202). The Polish version of the original, 20-item, JAWS was used to measure job-related affective states across the past month (van Katwyk et al., 2000). This version of JAWS includes 2 dimensions: valence and arousal, which allow to assess 4 categories of emotions: low-arousal positive emotions, high-arousal positive emotions, lowarousal negative emotions and high-arousal negative emotions. Results: The results of multidimensional scaling analysis showed that the theoretical circumplex model of emotions underlining JAWS was satisfactorily reproduced. Also the hypothesized 4-factor structure of the Polish version of JAWS was confirmed. The 12-item version had better fit with the data than the original, 20-item, version, but the best fit was obtained for the even shorter, 8-item version. This version emerged from a multidimensional scaling of the 12-item version. Reliabilities of the 20- and 12-item versions were good, with lower values for the 8-item JAWS version. Conclusions: The findings confirmed satisfactory psychometric properties of both Polish versions of the Job-related Affective Well-being Scale. Thus, when both psychometric properties and relevance for cross-cultural comparisons are considered, the 12-item JAWS is recommended as a version of choice.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2014, 27, 6; 993-1004
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stress intensity factor in the assessment of frost degradation of high-strength fibre-reinforced concretes
Współczynnik intensywności naprężeń w ocenie degradacji mrozowej fibrobetonów wysokowytrzymałych
Autorzy:
Borowska, Sylwia Anna
Powiązania:
https://bibliotekanauki.pl/articles/2067646.pdf
Data publikacji:
2020
Wydawca:
Politechnika Częstochowska
Tematy:
high-strength concrete
fibres
concrete degradation
stress intensity factor
surface scaling
beton wysokowytrzymały
włókna
degradacja betonu
współczynnik intensywności naprężeń
złuszczenie powierzchniowe
Opis:
The paper presents an assessment of the degradation of cyclic freeze/thaw on high-strength concretes, based on changes in the stress intensity factor KIC cycles and the total mass of surface scaling after 28 and 70 cycles. The degree of degradation was compared with the modification of stress intensity factor values. Three types of high-strength concretes (compressive strength about 90 MPa) were tested: concrete without fibres, concrete with steel fibres in the amount of 0.5% by volume (39 kg/m3) and concrete with a mixture of steel fibres (19.5 kg/m3) and basalt (6.8 kg/m3). The testing methodology is based on RILEM recommendations [1] and ASTM C666 [2] and PKN – CEN/TS 12390 Slab Test [3].
W pracy przedstawiono ocenę degradacji betonów wysokowytrzymałych poddanych cyklicznemu zamrażaniu/rozmrażaniu, w oparciu o zmiany współczynnika intensywności naprężeń KIC. Stopień zniszczenia na skutek cyklicznego zamrażania/rozmrażania BWW określono za pomocą modułu sprężystości podłużnej E, ubytku masy, redukcji wytrzymałości na ściskanie, wyznaczanych po 150, 250, 300 oraz 350 cyklach oraz sumarycznej masy złuszczeń powierzchniowych po 28 i 70 cyklach. Stopień degradacji porównano z modyfikacją wartości współczynnika intensywności naprężeń. Badaniom poddano trzy rodzaje betonów wysokiej wytrzymałości (wytrzymałość na ściskanie około 90 MPa): beton bez dodatku włókien, beton z włóknami stalowymi w ilości 0,5% objętości (39 kg/m3) oraz beton z mieszanką włókien stalowych (19,5 kg/m3) oraz bazaltowych (6,8 kg/m3). Metodologię badań oparto na zaleceniach RILEM [1] oraz normach ASTM C666 [2] i PKN – CEN/TS 12390 Slab Test [3].
Źródło:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo; 2020, 26 (176); 12-17
0860-7214
Pojawia się w:
Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies