Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "scale-up" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
The effect of process conditions on the flocculation process occurring in an agitated vessel
Autorzy:
Šulc, R.
Ditl, P.
Powiązania:
https://bibliotekanauki.pl/articles/779103.pdf
Data publikacji:
2012
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
flocculation
flocculation kinetics
mixing
Rushton turbine
flocculant dosage
scale up
Opis:
The effect of flocculation time, flocculant dosage, pollutant concentration, mixing intensity and tank size on flocculation performance was experimentally studied in a mechanically agitated vessel. The macroscopic approach was applied for fl occulation modelling. The simple semi-empirical generalized correlation for flocculation kinetics proposed by Šulc (2003a) and the simple semi-empirical generalized correlation quantifying the effect of flocculation time and flocculant dosage on fl occulation proposed by Šulc, Ditl (2007) were used for data treatment.
Źródło:
Polish Journal of Chemical Technology; 2012, 14, 3; 88-96
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of silo centrifuge testing
Autorzy:
Grossstück, M.
Schwedes, J.
Powiązania:
https://bibliotekanauki.pl/articles/1955776.pdf
Data publikacji:
2003
Wydawca:
Politechnika Gdańska
Tematy:
silo design
moist bulk solids
silo-centrifuge
scale-up
model tests
Opis:
Common problems of industrial silo design can be solved with the use of the Jenike method. The Jenike method is an established procedure to investigate the critical outlet dimensions of a silo and the flow profile. However, in some cases the Jenike method is assumed to lead to overdesign, especially when silo design is calculated for highly dispersed bulk solids in the nano range or if the bulk solid contains moisture. Another way to determine the critical outlet dimension of a silo is a model test. We then have to consider the boundary conditions, i.e. the particle size, and a possible size reduction of the model silo, which is only possible in a centrifugal field using cohesive bulk solids. In this work, results of experiments in a silo centrifuge regarding scale-up are presented. The experiments have been performed to investigate the critical outlet dimension for a silo for very fine and moist bulk solids.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2003, 7, 4; 549-560
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of laboratory conditions effect on prediction accuracy of size distribution of industrial ball mill discharge by using a perfect mixing model. A case study: Ozdogu copper-molybdenum plant
Autorzy:
Gharehgheshlagh, H. H.
Ergun, L.
Chehreghani, S.
Powiązania:
https://bibliotekanauki.pl/articles/110599.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ball mill scale-up
perfect mixing model
particle size distribution
simulation
Opis:
In this study, the perfect mixing model was used to investigate its accuracy level, under different laboratory conditions, in predicting the particle size distribution of industrial ball mills discharges. For this purpose, data sets of two laboratory ball mills with eight different compositions of balls and two industrial mills of a copper processing plant for seven different tonnages, which totally included 56 simulation operations, were used. For simulation, the necessary data were obtained through performing the breakage distribution function and kinetic grinding tests using laboratory mills. The results were used to determine the first order grinding kinetics and normalized breakage rate parameters. For the industrial scale, the simulation process was carried out using data, perfect mixing model equations and JKSimMet software. The results showed that the operating conditions of the laboratory mills were quite affected by the predictive power of the desired model. Comparing the measured and simulated values of P80, it is clear that 2 minutes of first order grinding using the Bond laboratory ball mill with standard operating conditions and single size ball load of 20 mm provided the best prediction with trivial errors, less than 10%, for all seven tonnages of the industrial mills. The results of this study together with more investigations on different plants can be helpful in optimization, simulation and scale-up procedures of ball mills.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 2; 1175-1187
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy przenoszenia skali w krystalizatorach z rurą cyrkulacyjną i mieszadłem
Scale-up problems in crystallizers with the draft tube and propeller
Autorzy:
Małysiak, A.
Synowiec, M.
Wójcik, J.
Powiązania:
https://bibliotekanauki.pl/articles/1215668.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
przenoszenie skali
krystalizator DTM
czas pierwotnej cyrkulacji
scale-up
DTM crystallizer
primary circulation time
Opis:
W artykule przedstawiono analizę zagadnienia przenoszenia skali na przykładzie jednego z typów krystalizatora powszechnie stosowanego w aplikacjach przemysłowych. Zdefiniowano istotny parametr procesowym, mający duży wpływ na powtarzalność technologii. Określono wymagania z punktu widzenia kinetyki procesu podczas przenoszenia skali oraz, biorąc pod uwagę najczęściej stosowaną procedurę, przeanalizowano możliwości i ograniczenia tego sposobu.
The paper deals with scale-up problems. The issue is discussed in the light of draft tube magma crystallizer, commonly used in crystallization processes from solution. Authors defined the parameters mainly affecting the crystallization and product requirements during scale-up on one hand and on another consider, what can be done when the traditional procedure is applied.
Źródło:
Chemik; 2014, 68, 3; 202-204
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do badania procesu mieszania w skali technicznej
Experimental setup for investigation of mixing process in a technical scale
Autorzy:
Wesołowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/2070136.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mieszanie
instalacja doświadczalna
skala techniczna
mixing
experimental set-up
technical scale
Opis:
W pracy przedstawiono oryginalne rozwiązanie konstrukcyjne stanowiska do badania procesu mieszania w układach jedno- i wielofazowych w technicznej skali. Podano inwarianty geometryczne układu pomiarowego. Opisano zakres zmienności parametrów operacyjnych oraz oprogramowanie kontrolne. Pokazano wyniki wstępnych testów rozruchowych stanowiska.
An original design of the experimental setup for mixing process investigation in one- and multi-phase systems in a technical scale is presented. Geometrical invariants of the measuring system is given. Ranges of the change of process parameters and control software are described. The results of initial experimental tests are shown.
Źródło:
Inżynieria i Aparatura Chemiczna; 2009, 1; 122-123
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies