Techno-economic Assessment of Retrofitting Heating, Ventilation, and Air Conditioning System – Case Study
Autorzy:
Alsalem, Yazan
Ayadi, Osama
Asfar, Jamil Al
Powiązania:
https://bibliotekanauki.pl/articles/24201603.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
retrofitting HVAC
boiler system
LCCA
life cycle cost analysis
GHG emissions
greenhouse gas emissions
VRF system
variable refrigerant flow
energy audit
Opis:
Retrofitting heating, ventilation, and air conditioning (HVAC) systems in existing buildings and applying energy-efficient technologies can significantly reduce energy consumption and greenhouse gases emissions. In this work, two options of HVAC retrofitting were proposed and discussed for the existing heating system of school of engineering at the University of Jordan as a case study. The experimental tests showed that only one of the three diesel boilers work normally while the other two boilers are not efficient, with actual efficiency of 25%. The first retrofitting was to upgrade the existing heating system to a liquefied petroleum gas (LPG) boiler system with estimated annual saving of 29,757 Jordanian dinar (JOD), and a payback period of 3.9 years. The second option for retrofitting was a new HVAC system for the building including heating and air conditioning with a variable refrigerant flow (VRF) system and heat pump chiller. The estimated cost showed that the VRF system was the lowest one in running cost in winter. The diesel boilers had the highest greenhouse gas emissions with an average value of 377.3 tons of CO2 per year, while LPG boilers achieved the second highest emissions of around 279 tons of CO2 per year, whereas the heat pump chiller in winter produced 199 tons of CO2 and the VRF system emitted 180 tons in winter. The LCCA economic analysis was performed for the proposed systems, showing that the LPG boilers system was more feasible than the diesel boilers system, while the VRF system was more feasible than the heat pump chiller system.
Źródło:
Journal of Ecological Engineering; 2023, 24, 3; 153--168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Retrofitting existing office building for efficient energy management and performance
Modernizacja istniejącego budynku biurowego dla efektywnego zarządzania energią
Autorzy:
Oluseyi, Peter Olabisi
Ezike, Ifunanya Lilian
Powiązania:
https://bibliotekanauki.pl/articles/2055086.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
Building Information Management
BIM
Energy Retrofitting Interventions
Heating Ventilation and Air-Conditioning
HVAC
Green Building Extensible Mark-up Language
modelowanie BIM
modernizacja energetyczna
ogrzewanie
wentylacja
klimatyzacja
oprogramowanie Green Building Extensible Mark-up Language
Opis:
This study focuses on designing an efficient energy utilization protocol for the University of Lagos Senate office building, to ensure the reduction of energy consumption, reduce the cost of power and also ensure energy efficiency. Pre-retrofitting, the energy consumption cost for the UNILAG senate office building was calculated to be ₦20, 236, 962 i.e. 776.78 EUI (kWh/m²/y) using the appliance approach. The impact of various retrofitting methods was also simulated and measured utilizing BIM tools such as Autodesk Maya, Autodesk Revit and Autodesk Insight. This resulted in an estimated reduction in energy consumption cost to between ₦19,304,038.05 and 18,549,199.3 post retrofitting, this translates to about 712 EUI (kWh/m²/y). Results show that a 4.61-8.34% reduction in energy usage for the senate house can be achieved using the methods proposed in this research.
Praca koncentruje się na opracowaniu procedury efektywnego wykorzystania energii w budynku biurowym Senatu Uniwersytetu w Lagos w celu zapewnienia redukcji zużycia energii, redukcji jej kosztów i zapewnienia efektywności energetycznej. Przed modernizacją koszt zużycia energii w budynku Senatu został obliczony jako ₦20, 236, 962, tj. 776.78 EUI (kWh/m²/y) w oparciu o zamontowane urządzenia. Symulowano wpływ różnych technik modernizacyjnych i prowadzono obliczenia korzystając z narzędzi opartych o technologię BIM, tj. Autodesk Maya, Autodesk Revit i Autodesk Insight. To doprowadziło do przewidywanej redukcji kosztów energii pomiędzy ₦19,304,038.05 i 18,549,199.3 po modernizacji, co odpowiada ok. 712 EUI (kWh/m²/y). Wyniki wskazują, że możliwa jest redukcja zużycia energii dla budynku Senatu na poziomie 4.61-8.34% w oparciu o metody przedstawione w pracy.
Źródło:
Structure and Environment; 2021, 13, 1; 16--28
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies