Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "retention time" wg kryterium: Temat


Tytuł:
Effect of Hydraulic Retention Time and Filling Time on Simultaneous Biodegradation of Phenol, Resorcinol and Catechol in a Sequencing Batch Reactor
Autorzy:
Thakur, C.
Mall, I. D.
Srivastava, V. C.
Powiązania:
https://bibliotekanauki.pl/articles/205058.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phenol
resorcinol
catechol
batch reactor
BR
hydraulic retention time
biodegradation
Opis:
In the present study, treatment of synthetic wastewater containing phenol, resorcinol and catechol was studied in a sequencing batch reactor (SBR). Parameters such as hydraulic retention time (HRT) and filling time have been optimized to increase the phenol, resorcinol, catechol and chemical oxygen demand (COD) removal efficiencies. More than 99% phenol, 95% resorcinol and 96% catechol and 89% COD removal efficiency was obtained at optimum conditions of HRT = 1.25 d and fill time = 1.5 h. The heating value of the sludge was found to be 12 MJ/kg. The sludge can be combusted to recover its energy value.
Źródło:
Archives of Environmental Protection; 2013, 39, 2; 69-80
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych warunków atmosferycznych na czas retencji gazów gaśniczych
Effects of Temperature, Pressure and Humidity on Retention Time Extinguishing Gases
Autorzy:
Kubica, P.
Wnęk, W.
Tuzimek, Z.
Domżał, A.
Powiązania:
https://bibliotekanauki.pl/articles/136661.pdf
Data publikacji:
2013
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
SUG gazowe
czas retencji
gazy gaśnicze
retention time
extingushing gases
Opis:
Skuteczność gaszenia gazami gaśniczymi za pomocą stałych urządzeń gaśniczych (SUG) zależy od czasu utrzymywania stężenia, tzw. czasu retencji. Odpowiednio długi czas retencji umożliwia wychłodzenie źródła pożaru oraz interwencję ekip ratowniczych. Na długość czasu retencji ma wpływ przede wszystkim szczelność pomieszczenia oraz różnica gęstości mieszaniny gaśniczej i otaczającego powietrza. Gęstość gazów uzależniona jest od warunków klimatycznych, w szczególności: ciśnienia, temperatury i zawartości pary wodnej. Na podstawie analizy przeprowadzonej w oparciu o wybrany model stosowany do wyznaczania czasu retencji, wykazano że pomijanie wpływu tych wielkości może wiązać się z istotnym błędem przy wyznaczaniu czasu retencji gazów o gęstościach bliskich gęstości powietrza.
The effectiveness of fixed gaseous extinguishing system depends on retention time – period time after discharge in which concentration of agent is high enough. It is important that an effective extinguishant concentration not only be achieved, but is maintained for a sufficient period of time to allow effective emergency action. This equally important in all classes of fires since a persistent ignition source (e.g. an arc, heat source or deep-seated fire) can lead to resurgence of the initial event once the extinguishant has dissipated. The longer the gas remains after the discharge, the better the level of protection offered. It is essential to determine the likely period during which the extinguishing concentration will maintained within the protected enclosure. The retention time can be determined in two ways: 1) full discharge test and measurement of gas concentrations at the required height; 2) door fan test and calculations based on the model gas flow out. The first method is expensive and rarely applied. Using the second method requires choose an appropriate model. Each of the known models assume ideal mixing of gas during its discharge from the cylinder. The air-agent mixture is created. This mixture then flows out the lower leakages, and air influences the upper. Difference in density of the ambient air ρ0 and the mixture inside enclosure ρm drives the flow of gases. Currently the following models are used to determine the retention time: a) model with a sharp interface between the agent-air mixture and the inflowing air (fig. 1) – Assuming that gas species do not diffuse results in an infinitesimally thin interface between inflowing fresh air and the agent–air mix resulting after dis-charge – model used in the standard NFPA 2001:2012 [1]; b) with a wide interface between the agent-air mixture and the inflowing air (fig. 2) – the wide interface model assumes that inflowing fresh air mixes instantaneously with the agent–air mixture to form a linear decay of agent concentration from the leading edge o the interface, to the uppermost elevation in the protected enclosure. model used in the standard PN EN 15004-1:2008 [2]; c) model with continuous mixing (fig. 3) – The inflowing air dilutes the mixture evenly - model used in PN EN 15004-1:2008 and NFPA 2001:2012, provided that the occurrence of forced mixing of the gases in the protected enclosure, such as air conditioners. For the analysis carried out in the article is selected model with a wide interface used in European standard. Retention time in this model is determined by the equations (3,4). Retention time in PN-EN 15004 [2] is measured from the moment of achievement the throughout the enclosure design concentration to the moment when the extinguishant concentration at 10% or 50% or 90 % of the enclosure height is less then 85% of the design concentration. The retention time shall be not less than 10 min. The density of gases depends on temperature and pressure of according to the equation (6). Air contains another factor – humidity, according to the equation (5). The density of the mixture of air-agent is determined by the formula (7). The difference between the density of the air surrounding the protected enclosure ρ0 and density of air-agent mixture inside the room affects the length of the retention time ρm according to equation (3). Two cases were analyzed: c) protected room located inside the building and its walls bordering spaces with similar parameters of air, d) walls of protected room are walls of building; air parameters inside and outside significantly different. For these cases, the following extreme conditions: c) climatic conditions inside and outside the same temperature: 18-26 oC, actual pressure 868-1050 hPa, humidity 40-60 %. d) climatic conditions inside: temperature: 18-26 oC, actual pressure 868-1050 hPa, humidity 40-60 %; climatic condi-tions inside: temperature -35 do 35 oC, actual pressure 868-1050 hPa, humidity 0 – 100 % The results of calculations for the climatic conditions in which the density difference reaches the highest values are pre-sented in Tables 3 i 4. In order to determine the effect of climatic conditions on the length of the retention time of the calculations were performed according to the model with a wide interface. Assumed a room with a capacity of 70 m3, height 2,8 m. Assumed leakage area 377 cm2 (n = 0,2191; k1 = 0,0374). Retention times were calculated for each agent assuming normative conditions and the most adverse climatic conditions. The results are shown in Table 5. Extinguishing gases with a density similar to air density reached the longest retention times in the group of analyzed gases (fig. 4). Retention time, gas consisting of 92% N2 and 8% Ar was ca. 5 times longer than halocarbon and over 2-times then Nitrogen. Under adverse climatic conditions that may occur inside the building and are identical in a protected space, and outdoor the room, retention time is changing (fig. 5). Retention time of Novec 1230, FM200 and Argonit was slightly shortened 1-2% (fig. 6). In case of Nitrogen was slightly longer - about 1%. The most significant changes (shortening by about 45%) concerned a mixture of 92%N2-8%Ar, which has density similar to the density of air in normative conditions. Under adverse climatic conditions that may exist between the protected space and the outside of the building, the density difference ρm - ρ0 reaches higher values. Despite this, the retention times of gases with high densities (FM200, Novec 1230) were slightly reduced, about 3% (fig. 8). The extinguishing gas density was more similar to the density of air, the more significant was the reduction in retention time, reaching almost 80% in the case of a mixture 92%N2-8%Ar (fig. 8).
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2013, 3, 47; 196-211
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamics of methane fermentation process and retention time for different agricultural substrates
Autorzy:
Lewicki, A.
Dach, J.
Janczak, D.
Czekała, W.
Rodríguez Carmona, P. C.
Powiązania:
https://bibliotekanauki.pl/articles/335195.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
biogas plants
agricultural substrates
methane fermentation process
retention time
experimentation
Polska
Opis:
A hydraulic retention time (retention) also known as HRT is one of the most important parameter in biogas plant exploitation. In practice, there are many substrates with different HRT used in agricultural biogas plant which makes difficulties in fermentation process optimization. The aim of this study was to investigate and compare the efficiency of biomethane production and to determine the dynamics of the fermentation process expressed by reaching 60, 80, 90 and 100% of HRT. The results showed very big differences in efficiency of methane production as well as HRT duration between analyzed substrates. The total fermentation period (100% of HRT) for investigated substrates amounted average 31,5 day (range: 21-41 days). However production of last 10% of methane average out 28%. It proves very low dynamics of fermentation process in the last phase.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2013, 58, 2; 98-102
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Współoczyszczanie ścieków z produkcji płyt pilśniowych w reaktorach SBR
Co-treatment of wastewater from fibreboard production in the SBR reactors
Autorzy:
Kamizela, T.
Powiązania:
https://bibliotekanauki.pl/articles/296935.pdf
Data publikacji:
2011
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ścieki
płyty pilśniowe
SBR
hydrauliczny czas retencji HRT
wastewater
fiberboard
hydraulic retention time HRT
Opis:
Przedstawiono wyniki badań dotyczące zastosowania reaktora SBR do oczyszczania ścieków z produkcji płyt pilśniowych. Negatywne oddziaływanie ścieków z tej gałęzi przemysłu na środowisko związane jest z ich wysokim obciążeniem ładunkiem organicznym, a także obecnością toksycznych oraz odpornych na rozkład biologiczny substancji. Własności tych ścieków narzucają konieczność ich współoczyszczania ze ściekami bytowo-gospodarczymi. Na potrzeby badań zastosowano mieszaninę ścieków przemysłowych oraz ścieków syntetycznych. Celem doświadczeń było określenie zależności pomiędzy parametrami dopływu, parametrami technologicznymi reaktorów, a efektywnością oczyszczania. W zakresie prowadzonych badań stwierdzono, że udział ścieków przemysłowych w ogólnej mieszaninie może wynosić powyżej 9% wkładu objętościowego. Stwierdzono, że reaktory działające w cyklu dobowym przy HRT w zakresie 4 ÷ 8 d spełniają rolę efektywnych systemów oczyszczania ścieków.
The article presents the results of studies concerning the application of the SBR reactors for treatment of wastewater from the fiberboards production. The negative impact of fiberboard wastewater on the environment is connected with high organic load of pollutions, presence of toxic and resistant to biodegradation substances. Properties of fiberboard wastewater requires their co-treatment with domestic wastewater. For the investigation used a mixture of industrial and synthetic wastewater. The aim of experiments was to determine the correlation between flow parameters, technological parameters of reactors, and the effectiveness of treatment. It was found that the proportion of industrial wastewater in the total mixture can be more than 9% of the volume contribution. Classified that the reactors operating in the daily cycle at hydraulic retention time 4 ÷ 8 d meet the roles of effective wastewater treatment systems.
Źródło:
Inżynieria i Ochrona Środowiska; 2011, 14, 2; 157-166
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Introducing key advantages of intensified flotation cells over conventionally used mechanical and column cells
Autorzy:
Hassanzadeh, Ahmad
Safari, Mehdi
Khoshdast, Hamid
Güner, Mustafa K.
Hoang, Duong H.
Sambrook, Tim
Kowalczuk, Przemyslaw B.
Powiązania:
https://bibliotekanauki.pl/articles/2146874.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
pneumatic flotation cells
energy input
mean particle retention time
fine particles
bubble size distribution
Opis:
The present paper introduces the key advantages of ImhoflotTM, JamesonTM, and RefluxTM flotation cells over the conventionally used mechanical and column cells from different perspectives. The impact of slurry mean retention time, bubble size distribution, and energy input was studied for all cell types. The mean retention time of laboratory scale ImhoflotTM (V030-cell) and RefluxTM flotation cells (RFC100) were measured experimentally using KCl as a tracer. Also, initially a statistical and practical overview of previously installed ImhoflotTM, and JamesonTM cells was presented in this work. It was found that more industrial data is available for the JamesonTM cell. The diagnostic results showed that RefluxTM, JamesonTM, and ImhoflotTM functionally operate similarly based on providing intensive turbulence in the downcomer. They were initially applied to the Australian and the UK coal industries and installed in the cleaning stage of flotation circuits, while there are now more applications in a wide variety of minerals across the world in different flotation stages. First pilot trials on a Russian gold ore were reported operating both JamesonTM and ImhoflotTM cells at the rougher-scalper and cleaner stages providing superior results using the ImhoflotTM cell as rougher-scalper and the JamesonTM at the cleaner. Formation of sub-micron and micron-sized bubbles, effective hydrodynamic characteristics, and low capital and operating costs were reported as major advantages of intensified flotation cells over the conventionally used ones in improving the recoverability of ultra-fine particles. Literature data showed that these cells provide greater gas-hold-up values (40-60%) over the mechanical (5-20%) and column cells (5-25%) with substantially lower power inputs. It was indicated that low mean slurry retention time could lead to a potential enhancement in their throughputs, but further industrial measurements are required to prove this statement. The RefluxTM cell showed a plug-flow mixing regime, while ImhoflotTM V-Cell followed the trend of perfect mixing and plug-flow dispersion regimes.
Źródło:
Physicochemical Problems of Mineral Processing; 2022, 58, 5; art. no. 155101
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The application of UASB reactor in meat industry wastewater treatment
Zastosowanie reaktora UASB do oczyszczania ścieków z zakładów mięsnych
Autorzy:
Kwarciak-Kozłowska, A.
Bohdziewicz, J.
Mielczarek, K.
Krzywicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/395840.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków z zakładów mięsnych
reaktor UASB
biogaz
meat industry wastewater
reactor UASB
hydraulic retention time
biogas
Opis:
The meat industry is a branch of the food sector, which significantly affects the degradation of the environment. Consuming large amounts of water consequently produces significant quantities of water which are characterised by a high organic content and high concentration of suspended solids, inorganic salts and nutrients. The study attempted to determine the influence of the HRT and OLR on biogas production and the treatment of wastewater from the meat industry, and it was found that the most preferred treatment process carried out was at HRT 3d (OLR-0.55 kgCOD/m3d). The anaerobic process under HRT 3d obtained a considerable degree of the removal of organic pollutants from raw wastewater designated as COD (79%), BOD (77%) and TOC (73%). The concentrations of COD and BOD were 350 mg/dm3 and 363 mg/dm3 respectively. The value of TOC reached a level of 142 mg/dm3. Due to its poor quality, effluent from a UASB reactor cannot be discharged into natural water without additional treatment processes. The addition of reverse osmosis in the meat industry wastewater treatment is suggested.
W badaniach podjęto próbę określenie wpływu czasu zatrzymania ścieków z zakładu mięsnego w reaktorze UASB na efektywność ich oczyszczania oraz na wielkość dobowej produkcji biogazu. HRT zmieniano w zakresie od 2 do 6 dób co wiązało się ze zmianą obciążenia komory ładunkiem zanieczyszczeń z 0,27 kgChZT/m3d do 0,82 kgChZT/m3d. Stwierdzono, że wraz ze skracaniem czasu zatrzymania z 6d do 2d, jakość ścieków ulega pogorszeniu, ale ilość produkowanego biogazu zwiększała się. Zaobserwowano, że wielkość współczynnika biogazu ulegała obniżeniu. Stwierdzono, że najkorzystniej prowadzić proces oczyszczania badanych ścieków przy HRT równym 3 doby z uwagi na dobre efekty oczyszczania i wysoki współczynnik produkcji biogazu wynoszący 0,45 dm3 biogazu/gChZT_us. Prowadzenie procesu fermentacji przy tak ustalonych warunkach pozwoliło na wysoki stopień usunięcia zanieczyszczeń oznaczanych, jako ChZT (79%), BZT5 (77%) i OWO (73%). Stężenie ChZT ścieków oczyszczonych wynosiło 350 mg/dm3, BZT5 463mg/dm3 a OWO 142 mg/dm3. Pomimo wysokiego stopnia usunięcia zanieczyszczeń z badanych ścieków nie ma jednak możliwości odprowadzenia ich do odbiornika naturalnego. Proponuje się, aby w kolejnych etapach badań podjąć próbę doczyszczania ścieków w procesie odwróconej osmozy co w przyszłości może pozwolić na zamknięcie obiegu wody na terenie zakładu.
Źródło:
Civil and Environmental Engineering Reports; 2011, 7; 119-128
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance analysis of the horizontal sub-surface flow constructed wetland under different hydraulic loading rates for rural domestic wastewater treatment
Autorzy:
Khairalla, A. M. O.
Xiwu, L.
Ladu, J. L.
Wenbo, Z.
Powiązania:
https://bibliotekanauki.pl/articles/207342.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
HFCW
Horizontal Flow Constructed Wetlands
rural sewage treatment plants
biological processes
retention time
oczyszczalnia hydrofitowa
wiejskie oczyszczalnie ścieków
czas retencji
procesy biologiczne
Opis:
The performance of horizontal subsurface flow constructed wetland (HFCW) for rural domestic sewage treatment has been evaluated. The system was built as a tertiary treatment after the biological processes to improve the effluent wastewater quality. The HFCW was operated in three phases under different hydraulic loading rates (HLRs), and with three kinds of aquatic plants i.e., water spinach, Chinese celery and cress. The vegetation growth parameters such as plant height, fresh and dry weights were monitored and analyzed. The influent and effluent concentrations of the chemical oxygen demand (COD), ammonium nitrogen (NH4+-N), total nitrogen (TN) and total phosphorus (TP) were measured. The average removal efficiencies at the first phase were 52.9%, 64.7%, 58.2% and 72.8%, and it reduced to 48.6%, 52.2%, 44.04% and 64.4% in the second phase for COD, NH4+-N, TN and TP, respectively. In the third phase, the HFCW system showed the following mean removal efficiencies: 51.2%, 74.2%, 58.5% and 80.9%. The results revealed that the removal efficiencies increased with decrease in the HLR and increased temperatures. The findings confirmed that the horizontal flow constructed wet-land is more convenient for the rural wastewater treatment with efficient nutrient removal.
Źródło:
Environment Protection Engineering; 2016, 42, 4; 107-121
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry środowiskowe oraz procesowe fermentacji metanowej prowadzonej w trybie ciągłym (CSTR)
Environmental and process parameters of methane fermentation in continuosly stirred tank reactor (CSTR)
Autorzy:
Kozłowski, K.
Dach, J.
Lewicki, A.
Cieślik, M.
Czekała, W.
Janczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/399814.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
biogazownia
fermentacja metanowa
parametry środowiskowe
parametry procesowe
obciążenie objętościowe
czas retencji
biogas plant
methane fermentation
environmental parameters
process parameters
organic loading rate
retention time
Opis:
Kluczowym wskaźnikiem procesu fermentacji metanowej, rzutującym na opłacalność funkcjonowania biogazowni, jest wydajna produkcja metanu w przeliczeniu na 1 m3 objętości czynnej reaktora. Zależy ona w dużej mierze od właściwego doboru parametrów środowiskowych oraz procesowych. W niniejszej pracy zebrano i przeanalizowano wpływ najważniejszych parametrów fermentacji metanowej prowadzonej w trybie ciągłym (CSTR), do których zalicza się temperaturę, pH, zawartość składników pokarmowych i stosunek C/N w podawanym podłożu, występowanie inhibitorów oraz obciążenie objętościowe reaktora fermentacyjnego, czas retencji i mieszanie reaktora fermentacyjnego. Nadal jednak wpływ wielu czynników pozostaje nieznany, stąd istnieje konieczność dalszych, kompleksowych badań.
A key indicator of methane fermentation process which influences the cost-effectiveness of the biogas plant is efficient production of methane per 1 m3 of reactor. It depends on a proper selection of environmental and process parameters. This article present collected and analyzed effect of most important parameters of continuous methane fermentation (CSTR), which include temperature, pH, nutrient content and the C/N ratio in the feed medium, the presence of inhibitors, and the volume load of reactor, retention time and mixing of digestion reactor. Still, the impact of many factors remain unknown, hence there is a need for more comprehensive studies.
Źródło:
Inżynieria Ekologiczna; 2016, 50; 153-160
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biomass-biogas recycling technique studies of municipal food waste disposal: a reviw
Badania nad technologiami odzysku biogazu z biomasy z żywnościowych odpadów komunalnych: przegląd
Autorzy:
Jin, Y
Wen, J
Nie, Y
Chen, H
Wang, G
Powiązania:
https://bibliotekanauki.pl/articles/1819373.pdf
Data publikacji:
2012
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
solid-liquid system
anaerobic digestion
leachate recirculation
methane production
activated sludge
retention time
performance
hydrolysis
water
stabilization
biomasa
fermentacja beztlenowa
odpady komunalne
recycling odpadów spożywczych
Opis:
Źródła energii znalazły się w centrum zainteresowania pod względem prawnym, etycznym, społecznym i gospodarczym z powodu rosnących problemów środowiska. Powszechnie wiadome, że nieodnawialne źródła energii są w coraz większym stopniu zastępowane innymi, które są odnawialne i mniej zanieczyszczające, z wykorzystaniem technologii mających na celu zrównoważony rozwój. Utylizacja stałych odpadów żywnościowych jest wciąż poważnym problemem dla wielu społeczności. Technologia beztlenowej fermentacji jest możliwa do zastosowania przy przetwarzaniu organicznych odpadów stałych i łączy odzysku materiału oraz produkcję energii. Recykling odpadów spożywczych w procesie beztlenowa fermentacja na biogaz, zawiesinę biogazu oraz nawóz organiczny jest podstawowym zadaniem utylizacji bioodpadów komunalnych. Bazując na sortowaniu odpadów spożywczych, technologia ta może zlikwidować zanieczyszczenia z odpadów spożywczych, w odniesieniu do ich źródeł. Z jednej strony złagodzić presję na środowisko pochodzące z spożywczych odpadów komunalnych oraz uniknąć wtórnego zanieczyszczenia, osiągnąć zasadę „3R” (Reduce, Reuse, Recycle) w gospodarce odpadami jeszcze bardziej. Zasada ta wprowadza zasady technik, przewagę technologiczną oraz postęp w dziedzinie badań nad beztlenową fermentacją. Fermentacja beztlenowa dzieli się na mokrą i suchą. W porównaniu z oczywistymi zaletami fermentacji na mokro, jest jeszcze wiele braków w procesie fermentacji suchej. Ostatecznie stwierdzono, że technologia suchej fermentacji do produkcji metanu zmieniła tradycyjne podejście do fermentacji. W pewnym sensie, usuwanie i recykling odpadów spożywczych jest w przybliżeniu podobny do zgazowania komunalnych odpadów spożywczych, co może zamienić odpady w majątek, który ludzkość może wykorzystać do zarządzania w metropoliach. I zdecydowanie rekomenduje się fermentację typu etanolowego jako najbardziej obiecujący typ acydyfikacyjny.
Źródło:
Rocznik Ochrona Środowiska; 2012, Tom 14; 21-55
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie komputerowe przepływów i jego wykorzystanie do poprawy pracy przykładowego wodociągu
The use of the computer modeling of flows for the work improvement of exemplary water supply system
Autorzy:
Orłowska-Szostak, M.
Powiązania:
https://bibliotekanauki.pl/articles/126040.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
system transportu
system dystrybucji wody
model komputerowy przepływów
kalibracja modelu
wiek wody
strefowanie ciśnienia
sterowanie przepływem
water transport systems
water distribution system
computer model of flows
model calibration
retention time of water in the network
zoning of pressure
flow control
Opis:
Zaprezentowano proces powstawania i niestandardowego wykorzystania modelu komputerowego przepływów w grupowym systemie transportu i dystrybucji wody wodociągowej (STDW) zaopatrującym cztery miejscowości gminy Wejherowo. Dane opisujące stan aktualny sieci obejmują m.in. topologię sieci, średnice, materiał oraz wiek przewodów, obiekty współpracujące z układem wodociągowym, występujące rozbiory wody i obecny charakter zapotrzebowania miasta na wodę wodociągową, a także parametry charakteryzujące jakość wody dostarczanej odbiorcom. W procesie gromadzenia tych danych, pozyskiwanych od przedsiębiorstwa wodociągowego, występowały ograniczenia odnośnie do ich asortymentu i dokładności. W tych warunkach starano się maksymalnie wykorzystać posiadane informacje z punktu widzenia niezbędnej wiarygodności powstającego modelu. Podobne podejście zaprezentowano podczas przeprowadzania kalibracji modelu, mając na uwadze, że obie czynności (gromadzenie danych i kalibracja) stanowią czynności komplementarne. Dane pomiarowe dotyczyły produkcji wody na ujęciach oraz ciśnień w wybranych węzłach sieci. W procesie kalibracji modelu wykorzystano zalety symulacji czasowo-przestrzennej, co pozwoliło na optymalne wykorzystanie posiadanych danych pomiarowych. W rezultacie osiągnięty został wysoki stopień korelacji wyników pomiarów w układzie wodociągowym z wartościami zasymulowanymi. Skalibrowany model posłużył do przeprowadzenia kompleksowej analizy pracy systemu. Analiza ta obejmowała m.in. czas przebywania wody w sieci wodociągowej, w poszczególnych jej częściach (tzw. wiek wody), mający istotny bezpośredni wpływ na jakość wody dostarczanej odbiorcom. Zaproponowano również pewne koncepcje modernizacji zmierzające do usprawnienia pracy nieoptymalnie działającego układu wodociągowego miasta. Wspomniane usprawnienie systemu obejmowało przede wszystkim korektę podziału systemu na strefy ciśnienia i sterowanie przepływami w sieci.
In the paper a process of coming into existence and a nonstandard use of the computer model of water transport and distribution system (STDW) for middle size (of about 50,000 inhabitants) city located in Pomorskie region was presented. Collecting the data describing current state of the system the authors concentrated their attention on the network of pipes (the network topology, diameters, material and the age of pipes), objects cooperating with the waterworks system, network fittings, appearing consumptions of water and current character of the water demand in the city and also some parameters being characteristic of a quality of water delivered to the consumers. All these data constituting the base for creating the model STDW were collected in the essential scope and with the essential accuracy. There appeared here some restrictions in the form of the assortment and accuracies of the data which the water authority had at their disposal. In these conditions the authors were trying to exploit to the maximum the gathered data from a point of view of the essential credibility of the model coming into existence. The similar approach was presented while making the calibration of the model bearing in mind that both activities (the completing of the data and the calibration) constitute activities of complementary character. The measuring data concerned water production at the water intakes and pressures occurring in chosen nodes of the water supply network. In the process of the calibration of the model advantages of the extended period simulation were exploited what allowed for the optimal use of the measuring data being for the author disposal. As a result a satisfactory correlation of results of measurements and simulated values has been achieved. The calibrated model was used for conducting the comprehensive work analysis of the system. This analysis included the residence time of water in the water supply network (so-called "age of water") having essential direct impact on the quality of water delivered to consumers. Also some concepts of modernization of the system were offered. They are aiming at streamlining the work of the non-optimal waterworks in the city. The mentioned streamlining the system included correction of the division of the system into zones of pressure and the control of flows.
Źródło:
Proceedings of ECOpole; 2017, 11, 2; 561-569
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies