The effect of wearing an FFP3 mask (3M$\text()^{TM}$ Aura$\text()^{TM}$) with an exhalation valve on gas exchange in medical staff
Autorzy:
Fantin, Raffaella
Powiązania:
https://bibliotekanauki.pl/articles/2093861.pdf
Data publikacji:
2021-12-13
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
personal protective equipment
health personnel
gas exchange
respiratory protective devices
COVID-19
masks
Opis:
ObjectivesThe physiological impact of wearing personal protective equipment (PPE), in particular filtering-face-piece 3 (FFP3) masks, has increasingly been gaining importance since the outbreak of coronavirus disease 2019 (COVID-19). So far, gas exchange has been examined using transcutaneously measured partial pressure of carbon dioxide (PaCO2), ergo-spirometry and impedance cardiography.Material and MethodsIn this structured investigation, arterial blood gas analysis in a 30-year-old female resident was carried out during a 13-hour day shift on the COVID-19 Intensive Care Unit of the University Hospital of Innsbruck, Austria. An FFP3 mask (3MTM AuraTM) with an exhalation valve was continuously worn, except for 1 break of 20 min. Arterial blood samples were obtained before putting on the PPE, and after 5 h, 9 h and 13 h of working in the contaminated area.ResultsDuring the multi-hour wearing time, an increase in PaCO2 (the baseline value: 29.3 mm Hg, the max. value: 38.9 mm Hg) and a continuous decrease in partial pressure of oxygen (PaO2, the baseline value: 102 mm Hg, the min. value: 80.8 mm Hg) was detectable.ConclusionsAll measured values were within the normal range, but a trend towards an insufficient gas exchange could be suspected.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2021, 34, 6; 817-819
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
COVID-19 and respiratory protection for healthcare providers
Autorzy:
Sozkes, Sarkis
Sozkes, Serda
Powiązania:
https://bibliotekanauki.pl/articles/2086073.pdf
Data publikacji:
2021-05-27
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
occupational health services
respiratory protective devices
pandemics
respirators
healthcare providers
occupational health of physicians
Opis:
This article has investigated the considerations of healthcare facilities to utilize reusable respirators as an alternative to disposable respirators during the COVID-19 pandemic. The decision to choose specific equipment should be based on the protection factors and also on the overall analysis of given conditions. International scientific databases, such as Web of Science, PubMed and MedLine, were searched on May 5, 2020, with the following key words: COVID-19, respiratory protection, surgical masks, filtering facepiece respirators (FFRs) and disposable respirators. The differences between various respiratory protective equipment, i.e., surgical masks, respirators such as FFRs, elastomeric half-facepiece respirators, elastomeric full-facepiece respirators and powered air-purifying respirators (PAPRs), were compared. Reusable elastomeric respirators (RERs) may provide a better adaptation to the face and may be more stable when used by healthcare providers (HCPs). Protection factors were found to be higher in FFRs compared to surgical masks. While FFRs provide a one-tenth decrease in the inhaled aerosol concentration, PAPRs diminish the inhaled aerosol up to one-twenty-fifth. Even with some full-face PAPRs and helmets, the protection factor assigned by the Occupational Safety and Health Administration can reach a value up to 1000. For HCPs, the evidence shown in this article provides an additional support for the utilization of RERs. Such equipment might be less prone to leakages, can provide a better fit, and indicates a better stability compared to disposable FFRs (N95 and similar). By providing higher protection factors, reusable elastomeric respirators are recommended to be used by HCPs under controlled cleaning and disinfection protocols.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2021, 34, 2; 307-318
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wskaźnik ochrony - podstawowe kryterium doboru sprzętu ochrony układu oddechowego
Protection factor - a basis for selecting respiratory protective devices
Autorzy:
Majchrzycka, K.
Powiązania:
https://bibliotekanauki.pl/articles/180296.pdf
Data publikacji:
2003
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ochrona układu oddechowego
środki ochrony indywidualnej
sprzęt ochrony układu oddechowego
respiratory protection
personal protective equipment
respiratory protective devices
Opis:
Autorka omawia początkowy etap prac zmierzających do ustalenia procedury doboru skuteczności sprzętu ochrony układu oddechowego, opartej na wskaźniku ochrony. W artykule przedstawiono kierunki badań prowadzonych w UE i w USA oraz założenia do krajowego programu badań ukierunkowanych na wyznaczenie wartości wskaźników ochrony różnych typów sprzętu.
The author discusses the first stage of creating a procedure based on a protection factor - for selecting respiratory protective devices. This paper presents the results of studies conducted in the EU and in the USA, as well as a new concept of determining the protection factor for different types of respiratory devices.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2003, 3; 25-27
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of Filtering Materials Used in Respiratory Protective Devices Against Nanoparticles
Autorzy:
Brochocka, A.
Makowski, K.
Majchrzycka, K.
Grzybowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/90497.pdf
Data publikacji:
2013
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
efficiency
filtering material
nanoparticles
respiratory protective devices
nanotechnologia
materiały filtracyjne
ochrony układu oddechowego
nanocząstki
skuteczność filtracji
Opis:
The basic aim of this research was to establish the efficiency of filtering materials widely used in respiratory protection devices with particular interest in their porosity, degree of electric and changeable process parameters, such as the flow rate of the test nanoaerosol and the size range of nanoparticles. Tests were carried out with an NaCl solid aerosol of 3.2 × 105 particles/cm3 for the range of particle size of 7–270 nm, at aerosol flow rate of 1800, 2700, 3600, 4500 and 5400 L/h. The tests showed that electrospun nonwovens were the most effective filtering materials for nanoparticles over 20 nm. Melt-blown electret nonwovens with lower porosity than electrospun nonwovens had higher values of penetration of 1%–4%. Those materials provided very efficient protection against nanoparticles of certain sizes only.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2013, 19, 2; 285-295
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nowelizacji norm na doskonalenie sprzętu ochrony układu odddechowego
Impact of amended standards on the improvement of personal protective equipment
Autorzy:
Pietrowski, P.
Bociek, K.
Powiązania:
https://bibliotekanauki.pl/articles/180266.pdf
Data publikacji:
2014
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
sprzęt ochrony układu oddechowego
norma
maska
filtr
półmaska filtrująca
respiratory protective devices
standard
full face mask
particle filter
filtering half mask
Opis:
Sprzęt ochrony układu oddechowego należy do najpopularniejszych środków ochrony indywidualnej, stosowanych głównie w przemyśle spożywczym, budowlanym, chemicznym, a przede wszystkim wydobywczym. Użytkownicy masek, filtrów i półmasek filtrujących zwracają szczególną uwagę na ich parametry ochronne w przewidywanych warunkach stosowania, ale także na walory użytkowe i dodatkowe funkcje tego rodzaju ochron, które często determinują chęć ich stosowania. W artykule przedstawiono rolę działań normalizacyjnych oraz nowelizacji (zmian) norm w stymulowaniu rozwoju i doskonaleniu poziomu technicznego wyrobów na przykładzie sprzętu ochrony układu oddechowego. Wprowadzenie nowych wymagań w zakresie parametrów ochronnych i użytkowych miało bezpośredni wpływ na wykorzystanie nowych materiałów, konstrukcji oraz metod wytwarzania tych środków, w celu zapewnienia ich wysokiej jakości oraz zachowania parametrów ochronnych i użytkowych w przewidywanym czasie użytkowania.
Respiratory protective devices are the most common personal protective equipment in food industry, architecture, chemical industry and, most of all, in miming. Users of full face masks, particle filters and filtering half-masks are especially concerned about their safety parameters under real conditions; however, whether that equipment will be used also depends on its usability and additional functions. This paper presents the role of standardization and amendments (changes) to standards in improving the technical level of products, using respiratory protection equipment as an example. The introduction of new requirements related to safety and functional parameters has a direct influence on the use of novel materials, designs and manufacturing methods in these products to ensure their high quality, and safety and functional properties during their lifetime.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2014, 1; 10-13
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Significance of Functional Studies Designing Filtering Half-masks with Superabsorbent Polymer
Znaczenie badań użytkowych w procesie projektowania półmasek filtrujących
Autorzy:
Brochocka, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/231868.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
respiratory protective devices
filtering half mask
superabsorbent polymer
comfort of use
sprzęt ochrony dróg oddechowych
półmaska filtrująca
polimer superabsorpcyjny
komfort użytkowania
Opis:
Functional studies of a range of personal protective equipment approved for distribution in European and international markets, conducted at different workplaces, showed that almost half of the participating workers did not find it comfortable. The objective of the work was to evaluate the comfort of use and functionality of a half-mask containing a superabsorbent polymer (SAP) designed for respiratory protection under harsh working conditions. The modifications implemented following functional studies were subsequently verified. The results of functional studies confirmed the hypothesis that nonwovens with SAP offer improved comfort of use. Filtering half-masks of modified construction fit users’ faces much better, without causing skin irritation or chafing; the masks were also free of pungent or offensive odors, which contributed to good user experience. The results show the significance of functional studies involving workers in real-life workplaces.
Badania użytkowe środków ochrony osobistej dopuszczonych do wprowadzania na rynek europejski i międzynarodowy przeprowadzone na różnych stanowiskach pracy wykazały, że prawie połowa badanych pracowników nie zaakceptowała ich jako wygodne w użytkowaniu. Aby środki te były bezpieczniejsze na stanowiskach pracy należy zwrócić uwagę na ich ergonomię, formę i styl. Dlatego niezbędne jest prowadzenie dalszych badań użytkowych w odniesieniu do poprawy komfortu użytkowania i zapewnienia skutecznej ochrony pracownikom na stanowisku pracy. Celem pracy była ocena wygody użytkowania i funkcjonalizacji modelu półmaski filtrującej zawierającej polimer SAP, przeznaczonej do ochrony układu oddechowego w warunkach ciężkiej pracy fizycznej oraz potwierdzenie poprawności dokonanych modyfikacji konstrukcji po badaniach użytkowych. Analiza wyników badań i obserwacji prowadzonych w zakresie użyteczności i funkcjonalności opracowanego modelu półmaski filtrującej potwierdziła słuszność założenia o poprawie komfortu użytkowania wprowadzając do materiału włókninowego polimer SAP. Zweryfikowany model półmaski filtrującej w zakresie jej konstrukcji okazał się zdecydowanie lepiej dopasowany do twarzy użytkownika i nie powodował odgnieceń i podrażnień skóry oraz nie wydzielał ostrych i nieprzyjemnych zapachów, co miało znaczący wpływ na wzrost komfortu użytkowania. Przedstawione wyniki badań wskazały jak duże znaczenie w projektowaniu sprzętu odgrywają badania użytkowe na rzeczywistych stanowiskach pracy z udziałem pracowników.
Źródło:
Fibres & Textiles in Eastern Europe; 2020, 2 (140); 61-66
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Safety of workers exposed to harmful airborne bioaerosols – legal status and innovations
Autorzy:
Majchrzycka, K.
Okrasa, M.
Szulc, J.
Gutarowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/410387.pdf
Data publikacji:
2017
Wydawca:
Politechnika Łódzka. Wydawnictwo Politechniki Łódzkiej
Tematy:
biosafety
bioaerosols
bioactive filtering nonwovens
respiratory protective devices
filtering half masks
bezpieczeństwo biologiczne
bioaerozol
bioaktywne włókniny filtracyjne
sprzęt ochrony układu oddechowego
półmaski filtrujące
Opis:
Filtering respiratory protective equipment is commonly used for protection against bioaerosols in industrial workplaces. However, the EU legislation does not specify the requirements for its antimicrobial properties. The result is that in the market there is no equipment available that would ensure complete safety of workers exposed to inhalation of harmful bioaerosols. This is particularly important in the case of equipment intended for multiple and long-term use. The aim of this study was to develop an innovative filtering half mask for the protection of respiratory tract that would have confirmed antimicrobial properties. The half mask was tested for compliance with EN 149:2001+A1:2009, and the survival rate of microorganisms in nonwovens was determined (E. coli bacteria and A. niger moulds). The reduction in the number of E. coli bacteria was 98.69% and the reduction in the number of A. niger moulds was 67.68% after 32 h of storage under conditions simulating the conditions of use of the equipment. It was found that the biocidal activity of the half mask is sufficient to ensure a significant reduction in the number of microorganisms during its long-term use in the workplace. This in turn means that continuous disinfection of respiratory protective equipment would be maintained even without employees’ intervention, which is not possible in case of standard respiratory protective equipment.
Źródło:
Biotechnology and Food Science; 2017, 81, 2; 159-168
2084-0136
2299-6818
Pojawia się w:
Biotechnology and Food Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ergonomic and Olfactometric Assessment of Anti-Odour Filtering Half-Masks under Real-Life Workplace Conditions
Ergonomiczna i olfaktometryczna ocena półmasek przeciwodorowych w warunkach pracy
Autorzy:
Brochocka, Agnieszka
Nowak, Aleksandra
Okrasa, Małgorzata
Powiązania:
https://bibliotekanauki.pl/articles/2056322.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
anti-odour half-mask
olfactometry
respiratory protective devices
degree of odour reduction
ergonomics
półmaska przeciwzapachowa
olfaktometria
sprzęt ochrony dróg oddechowych
stopień redukcji zapachów
ergonomia
Opis:
The presence of vapours and gases of chemical compounds in the atmospheric air contributes to mental discomfort as well as irritation of the respiratory tract and eyes. The technical solutions applied, such as collective protection measures, namely the encapsulation of processes or local ventilation equipped with appropriate air filters, are often insufficient. In such a case, respiratory protective equipment (RPE) is the basic and, in many cases, the only technical means that protects humans against the harmful effects of this type of harmful substance. The study evaluated the ergonomic and anti-odour properties of a novel filtering half-mask model with an oxygen indicator in functional workplace tests. In addition, the subjective anti-odour assessment results from functional tests were statistically compared with the results of olfactometric tests. The differences identified are attributable to the fact that the olfactometric method excludes subjects with olfactory impairments. Moreover, statistical analysis indicated significant differences in anti-odour properties between a reference half-mask and the filtering half-mask model with a nonwoven adsorbent layer (91% odour reduction). The filtering half-mask developed was found to provide high and very high levels of user comfort and exhibited excellent protective and functional properties, with a filtration performance of 96% and breathing resistance of 147 Pa. Those parameters qualify the filtering half-mask presented for protection class FFP2. In addition, the half-mask effectively absorber the vapours of malodorous substances up to 3 h and displayed oxygen concentration in the breathing zone. It should be noted that currently no such device is commercially available either in Poland or in the European Union.
Obecność wonnych par i gazów w powietrzu atmosferycznym może wiązać się z występowaniem dyskomfortu psychicznego, podrażnienia układu oddechowego i oczu. Stosowane rozwiązania techniczne w postaci środków ochrony zbiorowej, czyli hermetyzowania procesów czy wentylacja miejscowa wyposażona w odpowiednie filtry powietrza, są często niewystarczające. W takim przypadku sprzęt ochrony układu oddechowego (SOUO) jest podstawowym, a w wielu przypadkach jedynym, środkiem technicznym chroniącym człowieka przed szkodliwym działaniem tego typu substancji. W artykule przedstawiono ergonomiczne i przeciwodorowe właściwości nowego modelu półmaski filtrującej ze wskaźnikiem tlenu ocenione w funkcjonalnych testach prowadzonych na wybranych stanowiskach pracy. Analiza statystyczna wykazała istotne różnice we właściwościach antyzapachowych między referencyjną półmaską a modelem półmaski filtrującej z włókninową warstwą adsorbentu (redukcja zapachu o 91%). Stwierdzono, że opracowana półmaska filtrująca zapewnia wysoki lub bardzo wysoki poziom komfortu użytkownika oraz wykazuje bardzo dobre właściwości ochronne i użytkowe przy skuteczności filtracji 96% i oporze oddychania 147 Pa. Parametry te kwalifikują prezentowaną półmaskę filtrującą do klasy ochrony FFP2. Dodatkowo półmaska skutecznie absorbuje pary substancji o nieprzyjemnym zapachu do 3 godzin i wskazuje stężenie tlenu w strefie oddychania w czasie rzeczywistym. Należy zaznaczyć, że obecnie żadne takie urządzenie nie jest dostępne na rynku ani w Polsce, ani w Unii Europejskiej.
Źródło:
Fibres & Textiles in Eastern Europe; 2021, 5 (149); 91--99
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Filtration Properties of Nonwoven Structures with Superabsorbents for Respiratory Protective Devices
Ocena właściwości filtracyjnych struktur włókninowych zawierających superabsorbent stosowanych w konstrukcji sprzętu ochrony układu oddechowego
Autorzy:
Brochocka, A.
Powiązania:
https://bibliotekanauki.pl/articles/232087.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
nonwoven structure
filtering efficiency
superabsorbent polymers
respiratory protective devices
melt-blown process
struktura włókniny
efektywność filtrowania
superabsorbent polimerowy
sprzęt ochrony dróg oddechowych
proces melt-blown
Opis:
The paper presents a study of the protective and functional properties of nonwoven structures, such as penetration by solid and liquid aerosols, airflow resistance, and air moisture sorption capacity. Nonwovens were modified by the introduction of electrostatic charges in the structure of polymer fibers and by the addition of a superabsorbent polymeric (SAP) directly to the fiber-forming area in a melt-blown process. The resulting materials (outer nonwovens containing SAP of different grain sizes and filtering nonwovens with and without electrostatic charges) had varied morphological structures. The materials developed were characterised by high filtering efficiency at low airflow resistance and good moisture sorption ability. The study proved the possibility to apply nonwoven structures containing SAP in respiratory protective equipment used in harsh work environments at high temperature and relative humidity. The materials fabricated were found to improve hygienic comfort.
W artykule przedstawiono wyniki badań właściwości ochronnych i użytkowych opracowanych zmodyfikowanych pojedynczych i złożonych struktur włókninowych w zakresie penetracji wobec aerozoli stałych i ciekłych, oporów przepływu powietrza oraz zdolności do sorpcji wilgoci z powietrza podczas pracy oddychania. Modyfikacja polegała na wprowadzeniu ładunków elektrostatycznych w strukturę włókien polimerowych oraz superabsorbentu polimerowego (SAP) bezpośrednio do strefy wytwarzania włókien polimerowych w procesie melt-blown. Wytworzono struktury włókninowe o różnej budowie morfologicznej w postaci: włóknin osłonowych zawierających SAP o różnej ziarnistości oraz włóknin filtracyjnych z ładunkiem i bez ładunku elektrostatycznego. Charakteryzowały się one dobrą skutecznością filtracji przy zachowaniu oporów przepływu powietrza na odpowiedni poziomie i dobrą zdolnością do gromadzenia wilgoci. Badania pokazują nowe aplikacje struktur włókninowych zawierających polimer SAP w sprzęcie ochrony układu oddechowego, w którym będą pełnić określone funkcje w ciężkich warunkach pracy tj. wysokich temperaturach i wilgotności względnej powietrza z ukierunkowaniem na poprawę komfortu higienicznego podczas użytkowania.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 3 (123); 62-67
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biocidal Agent for Modification of Poly(lactic acid) High-efficiency Filtering Nonwovens
Środek biobójczy do modyfikacji wysoko skutecznych włóknin filtracyjnych z polimeru poli(kwasu mlekowego)
Autorzy:
Majchrzycka, K.
Brochocka, A.
Brycki, B.
Powiązania:
https://bibliotekanauki.pl/articles/233857.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
biocidal agent
poly(lactic acid)
melt-blown nonwoven
respiratory protective devices (RPD)
środek biobójczy
poli(kwas mlekowy)
włókniny filtracyjne
urządzenia do ochrony dróg oddechowych (RPD)
Opis:
The article presents research on the development of modified poly(lactic acid) (PLA) melt-blown nonwovens for construction of respiratory protection devices (RPD) against biological hazards. Due to this specific application of nonwovens, a new biocidal agent was developed which fulfils two basic criteria. The first one is the efficient destruction of microorganisms harmful for people, and the second is no negative influence on compost activity in the process of BIO-nonwoven biodegradation. The biocidal agent was composed of biologically active chemical compounds, which were permanently imbued into the perlite matrix. The modified poly(lactic acid) (PLA) melt-blown nonwovens were tested for basic filtering parameters with the use of standard model aerosols as well as bioaerosols. A microbiological study was performed to prove the antimicrobial activity of the modified nonwovens against Gram-positive and Gram-negative bacteria. It was shown that modified PLA at low concentrations did not eliminate microorganisms that dwell in organic compost, and that the time of BIO-nonwoven biodegradation was 56 days. Survival of microorganisms after 2 hours of contact with the BIO-nonwoven was zero %, which means that the nonwovens tested were characterised by activity at the highest level, 3rd,, towards Gram-positive and Gram-negative bacteria. At the same time, the effectiveness of the BIOnonwovens towards model aerosols (sodium chloride and mist of paraffin oil) was at a level that would ensure obtaining a 2nd class of protection of the filtering RPD.
W artykule przedstawiono badania ukierunkowane na doskonalenie właściwości modyfikowanych włóknin melt-blown z poli(kwasu mlekowego) przeznaczonych do konstrukcji sprzętu ochrony układu oddechowego przed zagrożeniami biologicznymi. Opracowano środek biobójczy spełniający dwa podstawowe kryteria: skuteczne niszczenie szkodliwych dla człowieka mikroorganizmów, przy jednoczesnym braku negatywnego wpływu na aktywność kompostu w procesie biodegradacji włóknin. Środek biobójczy stanowiły aktywne biologicznie związki chemiczne trwale naniesione w matrycy z perlitu. Badano podstawowe parametry filtracyjne przy wykorzystaniu aerozoli modelowych oraz bioaerozoli. Wykonano mikrobiologiczne badania aktywności kompostu organicznego, biodegradacji modyfikowanych włóknin, a także przeżywalności bakterii gram dodatnich i gram ujemnych w kontakcie z opracowanym środkiem biobójczym. Stwierdzono, że przy niskim stężeniu środek biobójczy nie eliminuje mikroorganizmów z kompostu. Czas biodegradacji modyfikowanych włóknin wynosił 56 dni. Przeżywalność mikroorganizmów po 2 godzinach kontaktu z włókniną spadła do zera, co oznacza, że badane włókniny charakteryzowały się aktywnością na najwyższym, trzecim poziomie wobec bakterii gram dodatnich i gram ujemnych. Jednocześnie osiągnięta skuteczność filtracji włóknin zapewniła uzyskanie filtrującego sprzętu ochrony układu oddechowego na poziomie drugiej klasy ochronnej.
Źródło:
Fibres & Textiles in Eastern Europe; 2015, 4 (112); 88-95
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies