Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "reproducibility" wg kryterium: Temat


Tytuł:
Estimating the Uncertainty of the Result for Tests of Resistance to Environmental Conditions on the Example of the Method of Resistance to Neutral Salt Mist According to EN ISO 9227 / ASTM B117
Autorzy:
Garbacz, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/27311596.pdf
Data publikacji:
2023
Wydawca:
Instytut Kolejnictwa
Tematy:
neutral salt spray
control charts
within-laboratory reproducibility
interlaboratory reproducibility
bias
metal workpieces
paint coatings
Opis:
Environmental laboratory tests are one of the most frequently performed tests to evaluate materials used, among others, for the construction of rail vehicles. The requirements of the EN ISO/IEC 17025 standard for research laboratories, particularly when evaluating the compliance of materials with the specified requirements, impose on laboratories the need to consider the results of final measurements along with the uncertainties of these results. Due to the complexity of the physical and chemical processes occurring during environmental tests, determining the sources of uncertainty of the measurement result can be very complicated. The article presents one of the methods of estimating the complex uncertainty for environmental tests on the example of corrosion tests using the NORDTEST TR 537 concept of uncertainty estimation. The article presents an exemplary method of uncertainty estimation based on a set of empirical data obtained in an accredited Laboratory for Testing Materials and Structural Elements of the Railway Institute with the use of within-laboratory reproducibility and method bias. Examples of uncertainty estimation depending on the type of tested objects (metal details and paint coatings) and the method of their evaluation after corrosion tests (quantitative and qualitative methods) are presented. The article also briefl y presents the possibilities of interpreting and processing the obtained data as part of the control carried out inside the laboratory on the basis of a simple statistical tool such as Shewhart control charts and the Ishikawa diagram for the method of determining corrosivity in salt chambers, identifying important factors influencing the measurement uncertainty and at the same time showing the complexity the entire research process.
Źródło:
Problemy Kolejnictwa; 2023, 198; 97--117
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda wyodrębniania odtwarzalnych konstrukcji werbo-nominalnych języka rosyjskiego z korpusów tekstowych
Autorzy:
Fedorushkov, Yury
Dzienisiewicz, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/1022939.pdf
Data publikacji:
2019-09-05
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
corpus
morphological analysis
regular expressions
reproducibility
collocation
Opis:
The article describes an extraction method of Russian verbal-nominative structures from electronic texts with the use of grammatical annotation and regular expressions syntax. The stages of the retrieval process are outlined. The list of extracted structures can be subsequently verified for the presence of reproducible units (phrasems).
Źródło:
Studia Rossica Posnaniensia; 2019, 44, 2; 379-394
0081-6884
Pojawia się w:
Studia Rossica Posnaniensia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Conventional periphrases of anthroponyms from a contrastive perspective (on the example of Polish periphrastic expressions and their Croatian equivalents)
Konwencjonalne peryfrazy zastępujące antroponimy w ujęciu kontrastywnym (na przykładzie polskich wyrażeń omownych i ich chorwackich odpowiedników)
Autorzy:
Szerszunowicz, Joanna
Vidović Bolt, Ivana
Powiązania:
https://bibliotekanauki.pl/articles/635962.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
contrastive analysis
figurative language
periphrasis
phraseology
reproducibility
Opis:
The focal issue of the present paper is the conventional periphrasis as an object of contrastive research. Such expressions may have different cross-linguistic equivalents, including full, partial, parallel and zero counterparts. The present paper aims to discuss Polish periphrastic expressions and their Croatian equivalents in order to determine and analyze the relations between the units in question. The Polish units (165) are lexicographically attested, while their Croatian counterparts have been determined on the basis of dictionaries, corpora and interviews with native speakers of the Croatian language. The conventional periphrasis have not been researched from this perspective and the results may be useful for Polish-Croatian lexicography. The study shows that zero equivalents constitute the biggest group (91), followed by full equivalents (61) with significantly less numerous groups of partial and parallel counterparts (respectively: 5 and 8).
Źródło:
Poznańskie Studia Slawistyczne; 2018, 15
2084-3011
Pojawia się w:
Poznańskie Studia Slawistyczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of non-fulfillment of assumptions on gage repeatability and reproducibility study evaluation
Autorzy:
Klaput, Pavel
Vykydal, David
Plura, Jiří
Powiązania:
https://bibliotekanauki.pl/articles/103999.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
normality
uniformity
repeatability
reproducibility
normalność
jednorodność
powtarzalność
odtwarzalność
Opis:
The evaluation of the measurement system quality has already become an integral part of quality planning activities in both the automotive and metallurgical industries. An important assumption for obtaining the most relia ble results is compliance with the basic assumptions for evaluating the variability of the measurement system. The main goal of this paper is to analyze, how the failure to meet the basic assumptions influences the evaluation of the measurement system's statistical properties. This goal is achieved by performing a detailed analysis of the latest developments in the field of measurement systems analysis aimed at verifying the assumptions of normality and uniformity. The evaluation of the effect of non-fulfillment of both assumptions on the values of the most important statistical properties of the measurement system is performed using simulated data. Suitable graphical tools are used for practical verification of both assumptions.
Źródło:
Quality Production Improvement - QPI; 2019, 1, 1; 472-478
2657-8603
Pojawia się w:
Quality Production Improvement - QPI
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reproducibility conditions for the pulsed X-ray emission in a vacuum spark discharge
Autorzy:
Georgescu, N.
Serbãnescu, C. G.
Sandolache, G.
Powiązania:
https://bibliotekanauki.pl/articles/148262.pdf
Data publikacji:
2001
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
plasma focus
reproducibility
vacuum spark
X-ray emission
Opis:
In our laboratory, a 1 kJ vacuum spark device is developed as a pulsed X-ray source for X-ray detector calibration and applications such as X-ray microscopy and microlithography. After our previous works for the X-ray emission maximization (up to around 10 J per pulse), this paper analyses the influence of four different triggering systems on the X-ray emission reproducibility. The main conclusion is that a high-power, very fast high voltage trigger pulse is required. In order to fulfill these conditions, a pulse transformer and an air spark gap have been added to the initial triggering device (a magnetic pulse compression circuit). With the new trigger pulse (20 J/pulse, 50 ns rise-time, 22 kV amplitude in an open circuit) a reasonable X-ray emission reproducibility is obtained.
Źródło:
Nukleonika; 2001, 46, suppl. 1; 17-20
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metrological Properties of the Test Setup for Determination Shielding Effectiveness of the Industrial Cable Connectors
Autorzy:
Kopka, R.
Tarczyński, W.
Pluta, S.
Powiązania:
https://bibliotekanauki.pl/articles/226200.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
shielding effectiveness
variance analysis
repeatability
reproducibility
industrial connectors
Opis:
The paper presents results related to assessment of the repeatability and reproducibility of the measurement test setup for determination the relative value of the shielding effectiveness coefficient of the industrial connectors. The construction of the proposed test setup, the measurement method and the procedure for the analysis of measurement results were described. To determine the value of the repeatability and reproducibility coefficient, the two–way analysis of variance was used, which additionally allows for an assessment of the influence of individual sources of variance. The measurements and their analysis were conducted for several frequencies in the range up to 1 GHz. Additionally, the expanded measurement uncertainty, including the test setup and instruments uncertainty was estimated.
Źródło:
International Journal of Electronics and Telecommunications; 2017, 63, 1; 11-18
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detailed analysis of grr study results and their visualization
Autorzy:
Mikulová, Pavlína
Plura, Jiří
Powiązania:
https://bibliotekanauki.pl/articles/104074.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
repeatability
reproducibility
factors
appraiser
visualization
powtarzalność
odtwarzalność
czynniki
rzeczoznawca
wizualizacja
Opis:
The paper presents the possibilities of analyzing the measurement system repeatability and reproducibility (GRR) analysis results in more detail and their visualization. Based on real data, the influence of appraisers’ behavior on GRR analysis results is evaluated. The measured data obtained in the GRR study by three operators are analyzed in more detail for cases involving only two operators. Comparison of the behavior of individual operators is performed using Gaussian curves, which allow to evaluate graphically the repeatability of individual operators and the reproducibility of measurement system. This approach makes possible to visualize the GRR analysis results with regard to behavior of individual operators. Obtained results make possible to improve the interpretation of GRR analysis results and are useful for measurement system improvement.
Źródło:
Quality Production Improvement - QPI; 2019, 1, 1; 479-486
2657-8603
Pojawia się w:
Quality Production Improvement - QPI
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Odtwarzalność rzeczywista, w testach PT, znormalizowanych procedur badawczych stosowanych w badaniu jakości paliw silnikowych. Część I. Badania kompetencji laboratoriów
Actual reproducibility, in PT tests, standardized testing procedures used in the testing of engine fuel quality. Part I. Proficiency testing of laboratories
Autorzy:
Altkorn, B.
Powiązania:
https://bibliotekanauki.pl/articles/1835439.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
norma czynnościowa
odtwarzalność
badanie kompetencji
functional standard
reproducibility
proficiency test
Opis:
Artykuł ma na celu stwierdzenie, czy normatywna odtwarzalność znormalizowanych procedur badawczych, podana w normach czynnościowych badania parametrów jakościowych paliw silnikowych do silników z zapłonem iskrowym, a określona na etapie opracowywania lub nowelizacji norm czynnościowych, jest zgodna z odtwarzalnością rzeczywistą, jaka jest osiągana w praktyce przez szerokie grono użytkowników danej normy. Oceny w praktyce dokonano poprzez analizę wyników badań międzylaboratoryjnych, przeprowadzanych przez liczną grupę uczestników, w których brały udział laboratoria Zakładu Analiz Naftowych INiG – PIB w latach 2010–2016. Z uwagi na dużą liczbę uczestniczących laboratoriów i różny stopień kompetencji, uzyskana przez nie odtwarzalność rzeczywista ma wysoką wartość statystyczną. Część I opisuje problemy, które mogą wystąpić podczas organizacji badania kompetencji laboratoriów.
The article seeks to ascertain whether the normative reproducibility of standardized test procedures, as set out in the functional standards for the quality testing of motor fuels for spark-ignition engines, and defined at the stage of developing or amending functional standards, is consistent with actual reproducibility achieved in practice by a wide circle of users of a given standard. Practical assessment was done by analyzing the results of interlaboratory tests carried out with the participation of a very large group of participants, amongst them the laboratories of the Department of Petroleum Analyses of the Oil and Gas Institute – National Research Institute in 2010–2016. Due to the large number of participating laboratories and the varying degrees of proficiency, the actual reproducibility achieved by them has a high statistical value. Part I describes the problems that may occur during the organization of proficiency testing of laboratories.
Źródło:
Nafta-Gaz; 2017, 73, 5; 365-371
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Urethral length measurement in women during sonographic urethrocystography – an analysis of repeatability and reproducibility
Pomiar długości cewki moczowej u kobiet podczas ultrasonograficznej uretrocystografii – analiza powtarzalności i odtwarzalności
Autorzy:
Wlaźlak, Edyta
Kociszewski, Jacek
Suzin, Jacek
Dresler, Maria
Surkont, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/1052712.pdf
Data publikacji:
2016
Wydawca:
Medical Communications
Tematy:
długość cewki moczowej
ultrasonografia
ultrasound
uroginekologia
measurement repeatability and reproducibility
Opis:
There has been a rise in the use of sonographic urethrocystography in patients with a full bladder. So far, no publications have been made on the analysis of repeatability and reproducibility of the measurements performed during this procedure. Aim: An assessment of repeatability and reproducibility of urethral length measurements during sonographic urethrocystography in females with a full bladder in the introital approach, using real-time two-dimensional transvaginal ultrasound. Material and methods: The ultrasound was performed in accordance with a standardized technique in female patients with a full bladder containing 200–300 mL of liquid. A total of 92 patients were included in the analysis. Results: The Intraclass Correlation Coefficient for repeatability and reproducibility of urethral length measurements in sonographic urethrocystography ranged between 0.9217 and 0.9873 (p = 0.0000). The analysis of ultrasound urethral length measurements taken by two different physicians at an interval of several months confirmed their very high compatibility (ICC = 0.81, p = 0.000). Conclusions: Very good repeatability and reproducibility of urethral length findings during sonographic urethrocystography performed in accordance with the presented technique support the possible use of this type of examination in both clinical practice and research.
Ultrasonograficzna uretrocystografia u pacjentek z wypełnionym pęcherzem moczowym jest coraz częściej stosowana. Nie opublikowano do tej pory analizy powtarzalności pomiarów zdejmowanych podczas tego badania. Cel pracy: Ocena powtarzalności i odtwarzalności pomiarów długości cewki moczowej podczas ultrasonograficznej cystouretrografii, wykonywanej u kobiet w czasie rzeczywistym, przezprzedsionkowo, głowicą przezpochwową w prezentacji dwuwymiarowej, z wypełnionym pęcherzem moczowym. Materiał i metody: Badanie ultrasonograficzne wykonywano zgodnie z wystandaryzowaną techniką u pacjentek z wypełnionym pęcherzem moczowym, zawierającym 200–300 ml płynu. Analizą objęto wyniki uzyskane od 92 chorych. Wyniki: Współczynnik ICC powtarzalności oraz odtwarzalności pomiarów długości cewki moczowej w ultrasonograficznej uretrocystografii wahał się od 0,9217 do 0,9873, p = 0,0000. Analiza pomiarów ultrasonograficznej długości cewki, wykonanych przez dwóch różnych lekarzy w odstępie kilku miesięcy, potwierdziła ich zgodność na bardzo dobrym poziomie (współczynnik korelacji wewnątrzklasowej = 0,81 przy p = 0,000). Wnioski: Bardzo dobra powtarzalność i odtwarzalność wyników pomiarów długości cewki moczowej podczas ultrasonograficznej uretrocystografii, uzyskanej zgodnie z opisaną techniką, stanowią potwierdzenie możliwości zastosowania tego badania w praktyce klinicznej i w badaniach naukowych.
Źródło:
Journal of Ultrasonography; 2016, 16, 64; 25-31
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Notes on the Fringes of the Replication Crisis in Management Science
Uwagi na marginesie kryzysu replikacji w naukach o zarządzaniu
Autorzy:
Hensel, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/1923649.pdf
Data publikacji:
2019-10-17
Wydawca:
Uniwersytet Warszawski. Wydawnictwo Naukowe Wydziału Zarządzania
Tematy:
methods
replications
reproducibility crisis
metody badań
badania replikacyjne
kryzys reprodukcyjności
Opis:
The text aims to provide an introduction to the replicability and reproducibility issue in management science while at the same time highlighting possible problems associated with replication research. The study is based on the review of the current literature. Three central issues are highlighted: a) the scarcity of replication attempts is caused by the incentive structure faced by management scholars, b) since the majority of published replications (interstudy and intrastudy) are authored by the researchers who conducted the original study, their results can be affected by the same incentives that affect the results of the original study, c) the popularity of research findings seems to be unaffected by failed attempts to reproduce them. This introductory treatment of the issue suggests that further examination of the relationship between the authorship and replication results is warranted. Increasing the number of replication studies requires a significant change in the incentive structure to which scholars are exposed.
Celem tekstu jest przedstawienie wprowadzenia do problemu replikowalności i reprodukowalności wyników w naukach o zarządzaniu, z jednoczesnym podkreśleniem wyzwań powiązanych z realizacją badań replikacyjnych. Tekst oparto na przeglądzie współczesnej literatury tematu. Wskazano na trzy główne kwestie: a) rzadkość badań replikacyjnych wynika ze struktury zachęt, z którą mają do czynienia badacze zarządzania; b) ponieważ większość opublikowanych badań replikacyjnych została przeprowadzona przez autorów replikowanego badania, ich rezultaty mogą być pochodną tej samej struktury zachęt; c) publikacja badań, w których nie udało się ponownie uzyskać wyników z oryginalnego badania wydaje się nie wpływać na popularność opracowań, których nie udało się powtórzyć. Tekst ma naturę wstępnej analizy zagadnienia, dlatego konieczne są dalsze badania poświęcone temu problemowi. Zwiększenie liczby badań replikacyjnych będzie wymagać zmiany struktury zachęt, na którą wystawieni są naukowcy.
Źródło:
Problemy Zarządzania; 2019, 4/2019 (84); 52-64
1644-9584
Pojawia się w:
Problemy Zarządzania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of operator’s impact on the measurement done using coordinate technique
Autorzy:
Ostrowska, K.
Szewczyk, D.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102406.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
R&R method
coordinate measuring arms (CMA)
operator impact
repeatability
reproducibility
Opis:
Coordinate measuring arms (CMAs) are devices which more and more often replace conventional coordinate measuring machines because of their undoubted advantages, such as mobility, the opportunity to increase the measuring volume, the opportunity to connect the optical probe, and above all, good price-quality ratio. Because these devices are handheld and redundant, what has the greatest impact on the measurement result accuracy are the operator, the machine kinematics and its ability to obtain repeatable measurement results; despite the fact that one point can be obtained from an infinite number of shoulders’ positions. In this paper it was determined by using R&R method how significant are the impacts of both the operator and the measuring device on the accuracy of measurements done with CMA, both with rigid switch probe and optical probe.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 20; 11-16
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
On Mainstreaming Philosophy of Science in Psychology Through “Psychological Theoretics
Autorzy:
Oppong, Seth
Powiązania:
https://bibliotekanauki.pl/articles/2118303.pdf
Data publikacji:
2022-03-31
Wydawca:
Katolicki Uniwersytet Lubelski Jana Pawła II. Towarzystwo Naukowe KUL
Tematy:
psychological theoretics
reproducibility crisis
theoretical psychology
philosophical psychology
philosophy of knowledge
Opis:
The principal goal of psychological science is not application but theory. This is because a good theory yields accurate predictions and control, two preconditions for applications. Thus, good psychological science is one that produces good theories. Against the background of reproducibility crisis and the apparent non-existence of an integrated subfield of psychology addressing those issues, I submit psychological theoretics (or psycho-theoretics) as a potential solution. The scope of psychological theoretics is outlined and distinguished from other closely related subfields. It was argued that psychological theoretics has the potential to make a unique contribution to the advancement of good psychological science. It is also worth noting that even if the global community of psychologists might not be ready for psychological theoretics as a new subfield, the reforms proposed under its rubrics would still remain relevant today and in the future. Indeed, the question of whether it is completely new will surely be the subject of scientific debate.
Źródło:
Roczniki Psychologiczne; 2022, 25, 1; 27-45
1507-7888
Pojawia się w:
Roczniki Psychologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Verification of the measurement system in a production organization
Analiza systemu pomiarowego w przedsiębiorstwie produkcyjnym
Autorzy:
Prístavka, Miroslav
Findura, Pavol
Beloev, Ivan
Kuboń, Maciej
Hrdá, Veronika
Kovalyshyn, Stepan
Shchur, Taras
Powiązania:
https://bibliotekanauki.pl/articles/2204298.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
accuracy of measurement device
repeatability
reproducibility
przyrząd pomiarowy
sprawność
powtarzalność
odtwarzalność
Opis:
Monitoring the accuracy of meters by qualified workers and managers is a preventive measure of every organization. The paper focuses on monitoring the accuracy of measuring devices and proposes preventive and corrective actions. The discussed measurement device was tested for accuracy using accuracy indexes Cg and Cgk. The identified deviations in measurements showed that the meter was not fully efficient. Consequently, actions were taken to ensuring that the measurement device is accurate.
Monitorowanie sprawności mierników to działanie prewencyjne każdej organizacji. Pracownicy działów jakości oraz osoby odpowiedzialne za kontrolę i pomiary wyrobów końcowych są zobowiązani do ciągłej kontroli sprzętu pomiarowego. W artykule skupiono się na monitorowaniu dokładności przyrządu pomiarowego oraz zaproponowaniu działań zapobiegawczych i korygujących. Dokładność przyrządu pomiarowego określono za pomocą wskaźników dokładności Cg i Cgk. Stwierdzono, że odchylenia w pomiarach świadczą o tym, że miernik nie jest w pełni sprawny. W związku z tym podjęto działania naprawcze, które zapewniły sprawność przyrządu pomiarowego.
Źródło:
Agricultural Engineering; 2022, 26, 1; 81--90
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alchemia pomiędzy pseudonauką a nauką. Studium historyczno-metodologiczne
Alchemy between pseudoscience and science. The Historical and Methodological Study
Autorzy:
Kazibut, Radosław
Powiązania:
https://bibliotekanauki.pl/articles/577285.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
alchemia
chemia
pseudonauka
kryterium demarkacji
powtarzalność i odtwarzalność
alchemy
chemistry
pseudoscience
demarcation
repeatability and reproducibility
Opis:
Traditionally, alchemy is regarded as an example of pseudoscience. In this paper I dispute this view and demonstrate that the practice of alchemy, in many aspects, can be interpreted as an experiment in protoscience. In the first part of the article, I introduce William R. Newman’s and Lawrence Principe’s analyses about the etymological origin of alchemy, its historiography and the origin of the separation between alchemy and chemistry. In the second part of the article I discuss different aspects on the practice of alchemy in light of the issues encountered with the inter-subjective repeatability of the experiments and the methods used to publicize the findings. In addition to the examination of the subjects researched, I also review the systematic elements found in the theoretical considerations presented by the alchemists.
Źródło:
Zagadnienia Naukoznawstwa; 2012, 48, 1 (191); 27-47
0044-1619
Pojawia się w:
Zagadnienia Naukoznawstwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Błędy histerezowe w pomiarach wilgotności względnej
Hysteresis errors in the relative humidity measurements
Autorzy:
Flakiewicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/152532.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wilgotność względna
błędy histerezowe
niepewność
wzorcowanie
powtarzalność
odtwarzalność
relative humidity
hysteresis errors
uncertainty
calibration
repeatability
reproducibility
Opis:
W pomiarach wilgotności względnej najczęściej wykorzystywane są czujniki sorpcyjne (głównie pojemnościowe) i psychrometryczne. W przypadku czujników psychrometrycznych dobra odtwarzalność zależy w praktyce od staranności i poprawności ich obsługi. Dlatego też w pracy omówiono zagadnienia powtarzalności i odtwarzalności w odniesieniu do higrometrów z czujnikami sorpcyjnymi, gdzie wpływ historii pomiaru na zmiany ich charakterystyk jest niezwykle istotny. Starzenie się czujników, kumulacja zanieczyszczeń i historia pomiaru (błędy histerezowe) mają zasadniczy wpływ na wyniki pomiarów i wzorcowania przyrządów. W konsekwencji sposób przeprowadzania wzorcowania, przedstawiania i interpretacji jego wyników jest bardzo istotny dla dokładności i jednoznaczności pomiarów wykonywanych przez użytkownika przyrządu. W pracy przedstawiono przykładowe wyniki pomiarów wykonywanych podczas wzorcowania, omówiono ich opracowanie oraz sposoby końcowego przedstawiania, z uwzględnieniem dostosowania zakresu podawanych informacji do realnych potrzeb użytkownika przyrządu.
In the relative humidity measurements mostly are used sorptive (esp. capacitive) and psychrometric sensors. In case of the psychrometric sensors good repeatability and reproducibility depends in practice on the care and correctness of its maintenance. Therefore in this paper are discussed questions concerning the repeatability and reproducibility of the hygrometers with the sorptive sensors, where the history of the measurements affect their characteristics is very important. Ageing of sensors, accumulation of impurities and history of the measurement (hysteresis errors) have the crucial influence on the results of measurements and calibration of instruments. In consequence the method of the calibration, form of presentation and interpretation of its results is very important for accuracy and unambiguity of measurement carried out by the operator of the instrument. In this paper are presented the example results obtained during calibration, was discussed their preparation and means of final presentation taking into account fitting the range of given information to the real necessity of the user of instrument.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 346-348
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies