Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "rentgenowska tomografia komputerowa" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Differences in trabecular bone mechanical strength measured by the x-ray microcomputed tomography and compressive test
Autorzy:
Binkowski, M.
John, A.
Nowak, R.
Bożek, M.
Bielecki, M.
Powiązania:
https://bibliotekanauki.pl/articles/333606.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
rentgenowska tomografia komputerowa
gęstość mineralna kości
wytrzymałość mechaniczna
x-ray microcomputed tomography
bone mineral density
mechanical strength
Opis:
The article describes the concept of measurement of the mechanical strength of trabecular bone dissected from human femoral head. When the studies are performed based on the human trabecular bone, there is a risk that correlation can be not achieved due to high discrepancy in the distribution of the bone density and mechanical properties. The compressive tests and X-ray microcomputed tomography with associated density phantom were used to deliver quantitative data. There is a conclusion that the selection of the region in the femoral head has to be performed very carefully. The region where cylinder is dissected can influence the results and produce fake data, which could not be correlated in the density of bone.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 15; 163-168
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry geometryczne przestrzeni porowej niskoporowatych piaskowców kambryjskich wyznaczone na podstawie wyników badań laboratoryjnych na próbkach z rdzeni wiertniczych
Geometric parameters of the pore space of low-porosity Cambrian sandstones determined on the basis of laboratory measurements results on core samples
Autorzy:
Krakowska, P.
Puskarczyk, E.
Habrat, M.
Madejski, P.
Jędrychowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1835140.pdf
Data publikacji:
2018
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
petrofizyka
rentgenowska tomografia komputerowa
przestrzeń porowa
porowatość
przepuszczalność
petrophysics
computed X-ray tomography
pore space
porosity
permeability
Opis:
Parametry geometryczne przestrzeni porowej skał pozwalają oszacować ich zdolności filtracyjne. Wysokorozdzielcza rentgenowska tomografia komputerowa dostarcza wiele różnorodnych parametrów ilościowych przestrzeni porowej. Niektóre z tych parametrów mogą być skonfrontowane z wynikami badań laboratoryjnych spektrometrii magnetycznego rezonansu jądrowego (NMR) i porozymetrii rtęciowej (MICP), np. średnia średnica porów. Piknometria helowa, rentgenowska tomografia komputerowa, spektroskopia magnetycznego rezonansu jądrowego i porozymetria rtęciowa dostarczają kluczowej informacji na temat wielkości porowatości. Przepuszczalność absolutna (wyznaczona metodą zaniku ciśnienia, ang. pressure-decay permeability, i impulsu, ang. pulse-decay permeability) pozwala ocenić zdolności filtracyjne skały. Na podstawie obrazów tomograficznych obliczono takie parametry przestrzeni porowej jak: liczba wokseli w obiekcie, pole powierzchni obiektu, średnica kuli o objętości równej objętości obiektu, maksymalna wartość grubości znaleziona w obiekcie, minimalna wartość grubości znaleziona w obiekcie, średnia grubość obiektu, odchylenie standardowe grubości, parametr określający odstępstwo kształtu obiektu od sfery, wydłużenie obiektu, płaskość obiektu, parametr określający podobieństwo kształtu obiektu do kształtu sferycznego za pomocą odpowiedniego stosunku objętości obiektu do powierzchni obiektu, charakterystyka Eulera, najkrótsza długość obiektu mierzona w danym kierunku (Fereta), najdłuższa długość obiektu mierzona w danym kierunku (Fereta), maksymalna średnica Fereta wyznaczona w kierunku prostopadłym do prostej określonej przez najdłuższą średnicę Fereta w obiekcie, stosunek maksymalnej długości średnicy Fereta wyznaczonej w kierunku prostopadłym do prostej określonej przez najkrótszą średnicę Fereta do długości najkrótszej średnicy Fereta, współczynnik kształtu (ShapeVa3D), moment bezwładności wokół najkrótszej osi głównej, moment bezwładności wokół średniej osi głównej, moment bezwładności wokół najdłuższej osi głównej. Dokonano interpretacji liczby porów i mikroszczelin w każdej analizowanej próbce poprzez analizę liczby obiektów w danej klasie objętości. Obrazy tomograficzne były interpretowane jakościowo i ilościowo przy wykorzystaniu programu poROSE (poROus materials examination SoftwarE), który jest wynikiem prac badawczych prowadzonych wspólnie przez ośrodki naukowe i przemysłowe na materiałach porowatych. Analizie poddano wartości porowatości (całkowitej i efektywnej), średnic porów (średnice Fereta, parametr grubości obiektu), parametrów określających kształt porów (np. wydłużenie, sferyczność, spłaszczenie) oraz stosowanych we wzorze Kozeny’ego–Carmana (np. wewnętrzna powierzchnia właściwa porów na jednostkę objętości porów). Przedstawiono wyniki analiz dla próbek zwięzłych piaskowców kambryjskich, będących potencjalnie skałami zbiornikowymi gazu zamkniętego (ang. tight gas). Próbki z rdzeni wiertniczych pochodzą z jednego otworu wiertniczego, z tej samej głębokości poboru rdzenia.
Geometric parameters of the rock pore space allow estimating their filtration abilities. High-resolution X-ray computed tomography (CT) provides a great amount of geometric parameters of the pore space. Some of these parameters may be confronted with laboratory measurements of nuclear magnetic resonance spectroscopy (NMR) and mercury porosimetry (MICP), e.g. average pore diameter. Helium pycnometry, CT, NMR and MICP provide key information on the porosity. Absolute permeability allows to assess the filtration abilities of the rock. The following pore space parameters for the object were calculated on the basis of tomo- graphic images: number of voxels, surface area, diameter of the sphere equal to the volume of the object, maximum thickness, minimum thickness, average thickness, standard deviation of thickness, parameter defining the deviation of the shape of the object from the sphere, elongation, flatness, parameter determines the similarity of the shape of the object to the spherical shape using the appropriate ratio of the object’s volume to the object’s surface, Euler number, the shortest and the longest length measured in a given direction (Feret), maximum Feret diameter determined in the direction perpendicular to the line defined by the longest Feret diameter in the object, ratio of the maximum length of the Feret diameter, attached in a direction perpendicular to the line defined by the shortest Feret diameter up to the shortest Feret diameter, shape coefficient (ShapeVa3D), moment of inertia around the shortest, mean and the longest major axis. The number of pores and microfractures in each of the analyzed samples were interpreted by analyzing the number of objects in a given volume class. The tomographic images were interpreted using the poROSE software (poROus materials examination SoftwarE), which is the result of research carried out jointly by scientific and industrial centers on porous materials. The analysis covered the values of porosity, pore diameters (Feret, thickness), parameters determining pore shape (e.g. elongation, sphericity, flatness) and used in the Kozeny–Carmana formula (e.g. internal pore surface per pore volume). The results of analyzes for tight Cambrian sandstones samples, potentially the tight gas reservoir rocks, are presented. Samples from cores come from one well, with the same probing depth.
Źródło:
Nafta-Gaz; 2018, 74, 11; 783-788
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tomograficzna ocena jakości odlewów ze stopu Haynes 282
Quality check of H282 castings by Computed Tomography (CT) technique
Autorzy:
Krzak, I.
Tchórz, A.
Pirowski, Z.
Jaśkowiec, K.
Grudzień, M.
Purgert, R.
Powiązania:
https://bibliotekanauki.pl/articles/391747.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
rentgenowska tomografia komputerowa (CT)
nieciągłości strukturalne
nadstopy niklu
Haynes 282
X-ray computed tomography (CT)
structural discontinuity
nickel superalloys
Opis:
W ramach prac projektu międzynarodowego realizowanego w Instytucie Odlewnictwa w Krakowie we współpracy z Energy Industries of Ohio opracowano technologię topienia w otwartym piecu indukcyjnym i grawitacyjnego odlewania nadstopów niklu. Dotychczas nadstopy te stosowane były wyłącznie jako przerabiane plastycznie. Do kontroli jakości wykonanych odlewów ze stopu Haynes 282 (H282) zastosowano między innymi rentgenowską tomografię komputerową (ang. Computed Tomography, CT). Jest to metoda nieniszcząca, która łączy badania rentgenowskie z zaawansowaną technologią komputerową. W niniejszej pracy zaprezentowano wybrane przykłady uzyskanych wyników badań zrealizowanych za pomocą rentgenowskiego tomografu komputerowego firmy GE Phoenix typu v/tome/x l-450 będącego na wyposażeniu Instytutu Odlewnictwa. Wszystkie operacje związane z obróbką danych z CT były wykonywane za pomocą oprogramowania datos/x - reconstruction i VGStudio Max 2.0.
As a part of the international project carried out at the Foundry Research Institute in Krakow in cooperation with Energy Industries of Ohio, anopen induction furnace melting technology and gravity casting of nickel superalloys have been developed. These alloys have been processed plastically so far. Quality control of Haynes 282 alloy (H282), was made with X-ray computed tomography (CT). CT is a non-destructive method that combines X-ray examinations with advanced computer technology. Selected results of the research obtained from the X-ray computer tomograph have been presented in the paper. Research were made by using the GE Phoenix v/ tome/x l-450 tompgraph type belonging to the Foundry Research Institute equipment. All operations related to the processing of CT data were performed using the datos/x-reconstruction and VGStudio Max 2.0 software.
Źródło:
Prace Instytutu Odlewnictwa; 2018, 58, 4; 219-225
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obrazowanie przestrzeni porowej skał o zróżnicowanej litologii metodą tomografii rentgenowskiej
Pore space imaging of rocks of various lithology by X-ray tomography
Autorzy:
Drabik, Katarzyna
Przelaskowska, Anna
Skupio, Rafał
Kubik, Benedykt
Powiązania:
https://bibliotekanauki.pl/articles/31344051.pdf
Data publikacji:
2022
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
rentgenowska tomografia komputerowa
wizualizacja
przestrzeń porowa
porowatość
kawerny
szczeliny
X-ray computed tomography
pore space
visualization
porosity
caverns
fractures
Opis:
W ostatnich latach obserwuje się dynamiczny rozwój laboratoryjnych metod nieniszczących przeznaczonych do badań własności skał. Należy do nich metoda rentgenowskiej tomografii komputerowej (CT), dająca możliwość wizualizacji wewnętrznej przestrzeni porowej skał bez naruszenia ich struktury. W pracy pokazano zastosowanie metody CT w skałach charakteryzujących się znacznym zróżnicowaniem przestrzeni porowej. Zmienność ta związana jest z występowaniem dużej ilości nieregularnie rozmieszczonych porów i kawern oraz szczelin o różnym stopniu wypełnienia. W ramach pracy wykonano obrazowanie przestrzeni porowej wraz z podziałem na porowatość szczelinową i kawernistą dla wybranych fragmentów rdzeni obejmujących wapienie, anhydryty i zlepieńce. Badania przeprowadzono z rozdzielczością 0,130 mm. Na ich podstawie uzyskano wartości porowatości dla metrowych odcinków rdzeni wiertniczych oraz dla wybranych fragmentów rdzenia. W przypadku anhydrytu podział na porowatość związaną z porami (0,18%) i porowatość kawernistą (0,26%) świadczy o stosunkowo dużej zawartości większych pustek w skale, co prawdopodobnie jest związane z rozpuszczaniem soli. Analiza dwóch fragmentów rdzenia wapienia uwidoczniła dużą zmienność struktury przestrzeni porowej. Na porowatość górnego fragmentu składa się, w największym stopniu, porowatość związana z drobnymi pustkami (1,79%). Porowatość pochodząca od kawern to 1,09%, natomiast porowatość szczelinowa stanowi najmniejszy procent porowatości całkowitej i wynosi 0,41%. Porowatość dolnego fragmentu rdzenia jest znacznie niższa. Składają się na nią głównie pory (0,42%) oraz w mniejszym stopniu kawerny (0,25%), natomiast porowatość szczelinowa stanowi zaledwie 0,05%. Porowatość zlepieńca jest bardzo niska (0,29%) i obejmuje głównie drobne pory i kawerny. Zastosowana metoda rentgenowskiej tomografii komputerowej pozwoliła na rozszerzenie charakterystyki przestrzeni porowej w badanych skałach i otrzymanie pełniejszej informacji na temat rozkładu porów, kawern i szczelin w rdzeniach.
In recent years, a dynamic development of non-destructive laboratory methods used in rock measurements has been observed. One of such methods is X-ray computed tomography. It is a very effective method of examining drill cores, enabling the visualization of the internal pore space of rocks without disturbing their structure. This paper shows the application of X-ray computed tomography in rocks characterized by a significant variability of pore space. This variability is related to the presence of a large number of irregularly distributed pores and caverns as well as fractures filled to a various degree with cement or clastic material. In this study, pore space visualization was performed along with the division into fracture and cavernous porosity for selected core sections of limestones, anhydrites and conglomerates. The tests were carried out with a resolution of 0.130 mm. Averaged porosity values were obtained for one meter long sections of drill cores and for selected parts of the cores. In the case of anhydrite, the division into pore-related porosity (0.18%) and cavernous porosity (0.26%) indicates a relatively high content of larger voids in the rock, which is probably related to salt dissolution. Analysis of two limestone core fragments highlighted a large variation in pore space structure. Porosity of the upper fragment is associated mainly with small voids (1.79%). Porosity derived from caverns is 1.09%, while fracture porosity represents the smallest percentage of total porosity at 0.41%. The total porosity of the lower core section is much smaller, consisting mainly of pores (0.42%), to a lesser extent of caverns (0.25%), and fracture porosity accounts for as little as 0.05%. Porosity of the conglomerate is very low (0.29%), consisting mainly of pore-related and cavernous porosity. The method used allowed us to enhance the pore space characterization in the studied rocks and obtain more complete information on the distribution of pores, caverns and fractures in the cores.
Źródło:
Nafta-Gaz; 2022, 78, 10; 713-719
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected features of carbonate rocks based on the X-ray computed tomography method (CT)
Wybrane cechy skał węglanowych w odwzorowaniu rentgenowskiej tomografii komputerowej (CT)
Autorzy:
Urbaniec, A.
Drabik, K.
Dohnalik, M.
Powiązania:
https://bibliotekanauki.pl/articles/1835191.pdf
Data publikacji:
2018
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
X-ray computed tomography
carbonate rocks
texture features
biogenic structures
porosity
fractures
rentgenowska tomografia komputerowa
skały węglanowe
cechy teksturalne
struktury biogeniczne
porowatość
szczeliny
Opis:
The paper presents possibilities of X-ray computed tomography (CT) application in view of representing selected features of carbonate rocks in a CT image. 72 sections of drill cores, approx. 1 m long each, were selected for tomographic examinations to obtain as reliable as possible results. The selected core material represents carbonate formations of various ages (from Palaeozoic to Upper Cretaceous), originating from boreholes situated in the Carpathian Foreland area. The interpretation of tomographic examinations was connected with a detailed sedimentological analysis of selected core sections, allowing to carry out direct comparisons, which of studied features and to what extent have disclosed in the CT images, and also whether this image can supplement or make the prepared descriptions more detailed. The presented information has a qualitative nature, i.e. referring mainly to descriptive features of the analysed carbonate rocks. Because of a limited size of the paper we have focused only on a few from numerous analysed features of carbonate rocks. The method of X-ray computed tomography (CT) can be very helpful at the analysis of various carbonate rocks features, such as structural and textural features, biogenic structures, porosity, and fracturing. It should be emphasised that this is a non-invasive method, providing a possibility to reproduce the CT image in various directions, without the necessity of mechanical interference in the rock material, resulting in the core destruction. Mummified siliceous sponges were examples of biogenic structures, which were best reflected in formations, which have been subjected to processes of selective dolomitization. In such type of carbonate rocks the sponge mummies were not dolomitized, while the basic material of the background was dolomitized. A very good representation of the structure in CT images was obtained for colonial hexacorals from the Scleractinia group, because many details of their skeleton structure are noticeable. Contrary to siliceous sponges the structure of corals is preserved much worse in the case, when the studied deposits were subject to diagenetic processes (such as dissolution, recrystallisation, or dolomitization). In addition, the analysis of various bioclasts, preserved in carbonate rocks, has shown a significant role both of the original mineral component building the skeletal elements of organisms (aragonite, high-magnesium calcite, lowmagnesium calcite), and of diagenetic processes history, directly affecting the condition of those components preservation. Based on the analysed materials it was found that porosity and fracturing are among best reflected features of carbonate rocks in the CT image. Open fractures, fractures filled with anhydrite and fractures filled with clay-marly material are generally well reflected in the CT image. Instead, fractures filled with calcite are variously recognisable, depending on the mineral composition of the rock background.
W artykule przedstawiono możliwości wykorzystania rentgenowskiej tomografii komputerowej (CT) pod kątem odzwierciedlenia wybranych cech skał węglanowych w obrazie CT. Do badań tomograficznych wytypowano 72 odcinki rdzeni wiertniczych o długości ok. 1 m każdy w celu uzyskania możliwie najbardziej wiarygodnych wyników. Wytypowany materiał rdzeniowy reprezentuje utwory węglanowe różnego wieku (od paleozoiku po górną kredę), pochodzące z otworów wiertniczych, zlokalizowanych na obszarze przedgórza i w podłożu Karpat. Interpretację badań tomograficznych powiązano ze szczegółową analizą sedymentologiczną wybranych odcinków rdzeni, co pozwoliło na bezpośrednie porównanie, które z badanych cech i w jakim stopniu ujawniły się w obrazie tomograficznym, a także czy obraz ten jest w stanie uzupełnić lub uszczegółowić wykonane opisy. Przedstawione informacje mają charakter jakościowy, tj. odnoszący się głównie do cech opisowych analizowanych skał węglanowych. W związku z ograniczoną objętością artykułu skoncentrowano się jedynie na kilku spośród wielu przeanalizowanych cech skał węglanowych. Metoda rentgenowskiej tomografii komputerowej (CT) może być bardzo pomocna przy analizie różnego typu ich cech, takich jak: cechy strukturalne i teksturalne, struktury biogeniczne, porowatość, szczelinowatość. Należy podkreślić, że jest to metoda nieinwazyjna, dająca możliwość odtwarzania obrazu tomograficznego w różnych kierunkach, bez konieczności mechanicznej ingerencji w materiał skalny, prowadzącej do niszczenia rdzenia. Spośród przeanalizowanych struktur biogenicznych uwagę zwrócono na zmumifikowane gąbki krzemionkowe, które w najlepszym stopniu odwzorowane zostały w zapisie CT w utworach, które w trakcie diagenezy poddane zostały procesom selektywnej dolomityzacji. W tego typu utworach mumie gąbek nie uległy dolomityzacji, podczas gdy masa podstawowa otaczającego osadu została zdolomityzowana. Bardzo dobre odzwierciedlenie struktury w zapisie CT uzyskano dla kolonijnych koralowców sześciopromiennych z grupy Scleractinia, gdyż w obrazie tomograficznym dostrzegalnych jest wiele detali budowy ich szkieletu. W przeciwieństwie do gąbek krzemionkowych, struktura koralowców zachowana jest znacznie gorzej w przypadku, gdy badane utwory poddane zostały w większym stopniu procesom diagenetycznym (takim jak rozpuszczanie, rekrystalizacja czy też dolomityzacja). Ponadto analiza różnego typu bioklastów, zachowanych w skałach węglanowych, wykazała istotną rolę, zarówno pierwotnego składnika mineralnego budującego elementy szkieletowe organizmów (aragonit, kalcyt wysokomagnezowy, kalcyt niskomagnezowy), jak również historii procesów diagenetycznych, mających bezpośredni wpływ na stan zachowania tych elementów. Na podstawie przeanalizowanych materiałów stwierdzono, że porowatość i szczelinowatość są jednymi z najlepiej odwzorowanych w zapisie tomograficznym cech skał węglanowych. W obrazie CT na ogół w bardzo dobrym stopniu czytelne są szczeliny otwarte, szczeliny wypełnione anhydrytem oraz szczeliny wypełnione materiałem ilasto-marglistym. Natomiast szczeliny zabliźnione kalcytem rozpoznawalne są w różnym stopniu, w zależności od składu mineralnego tła skalnego.
Źródło:
Nafta-Gaz; 2018, 74, 3; 183-192
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza petrofizyczna łupków sylurskich z synklinorium lubelskiego
Petrophysical analysis of Silurian shales from the Lublin synclinorium
Autorzy:
Krakowska, P.
Puskarczyk, E.
Jędrychowski, M.
Habrat, M.
Madejski, P.
Jarzyna, J.
Powiązania:
https://bibliotekanauki.pl/articles/972364.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
petrofizyka
łupki sylurskie
synklinorium lubelskie
spektrometria magnetycznego rezonansu jądrowego
rentgenowska tomografia komputerowa
petrophysics
Silurian shales
Lublin synclinorium
nuclear magnetic resonance
X-ray computed tomography
Opis:
Wyniki badań laboratoryjnych formacji sylurskich pozwalają na uzyskanie szczegółowych informacji na temat złożoności przestrzeni porowej, występowania mikroszczelin, a także obecności pirytu w skale. Trzy próbki mułowców sylurskich pochodzące z różnych głębokości, z jednego otworu zlokalizowanego w synklinorium lubelskim, zostały przebadane pod kątem wyznaczenia właściwości sprężystych, czyli prędkości fal podłużnych P i poprzecznych S, dynamicznych modułów: sprężystości podłużnej (Younga), odkształcenia postaci, odkształcenia objętości, współczynnika Poissona oraz zbiornikowych, z wykorzystaniem spektrometrii magnetycznego rezonansu jądrowego (porowatość całkowita i efektywna, zawartość wody wolnej, kapilarnej i nieredukowalnej). W ramach dodatkowych analiz przeprowadzono badania laboratoryjne przepuszczalności absolutnej w skali nano-Darcy, a także granulometrii. Rentgenowska tomografia komputerowa dała możliwość interpretacji jakościowej wykształcenia przestrzeni porowej oraz mikroszczelin, a także formy występowania pirytu w skale. Interpretacja ilościowa obrazów tomograficznych dostarczyła parametrów geometrycznych porów, pirytów i mikroszczelin, tj. wielkości porów i kryształów pirytów, mikroszczelin itp. Komplementarna analiza petrofizyczna skał łupkowych, wykonana przy wykorzystaniu różnorodnych metod badawczych, stała się kluczem do zrozumienia budowy wewnętrznej tego typu skał, które wykazują silną heterogeniczność parametrów fizycznych i chemicznych szkieletu ziarnowego i przestrzeni porowej.
The results of laboratory measurements of the Silurian formations allow detailed information on the complexity of pore space, the occurrence of microcracks, as well as the presence of pyrite in the rock to be obtained. Three samples of Silurian mudstones from different depths, from one well located in the Lublin synclinorium, were tested for elastic properties, i.e. the longitudinal waves P and transverse S, the dynamic moduli: Young, shear, bulk, Poisson ratio and reservoir using nuclear magnetic resonance spectrometry (total and effective porosity, free water, capillary and irreducible water). Additional laboratory analyses of the absolute permeability on a nano-Darcy scale as well as granulometry were performed. X-ray computed tomography provided an opportunity to interpret the qualitative development of porous space as well as the microscopic and forms of pyrite in the rock. The quantitative interpretation of tomographic images provided the geometric parameters of pores, pyrites and microcracks, i.e. the size of pores, pyrite crystals and microcracks. The complementary petrophysical analysis of shale gas deposits, made using a variety of research methods, became the key to understanding the internal structure of this type of rock, which exhibits strong heterogeneity in physical and chemical parameters of the particle's skeleton and pore space.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2017, 101; 293-301
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyniki badań testu wytrzymałościowego próbki węgla w świetle badań tomograficznych
Research results of triaxial geomechanical tests of a coal sample in the light of tomographic tests
Autorzy:
Dohnalik, Marek
Krakowska-Madejska, Paulina
Puskarczyk, Edyta
Jelonek, Iwona
Powiązania:
https://bibliotekanauki.pl/articles/2146244.pdf
Data publikacji:
2021
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
rentgenowska tomografia komputerowa
analiza obrazu
test wytrzymałościowy
prędkość fal P i S
computed tomography
image analysis
geomechanical test
P-wave and S-wave velocity
Opis:
Celem niniejszej pracy było sprawdzenie możliwości wykorzystania rentgenowskiej tomografii komputerowej (CT) do obserwacji spękań w badanej próbce węgla przed i po teście geomechanicznym, przeprowadzonym w stanie trójosiowych naprężeń (TRX). W pracy przedstawiono zastosowanie dwóch specjalistycznych technik laboratoryjnych: rentgenowskiej tomografii komputerowej i geomechanicznego trójosiowego testu ściskania. Testy geomechaniczne przeprowadzono za pomocą zestawu pomiarowego TRX-070, GCTS (USA), rejestrując pełną charakterystykę naprężeniowo-odkształceniową. Podczas trójosiowych testów ściskania wykonano też innowacyjne równoczesne pomiary prędkości fal P i S. Próbkę analizowano w dwóch etapach, zdefiniowanych ze względu na stan próbki w obrazie CT: pomiar CT wykonany na nienaruszonej próbce węgla (etap 1) oraz otrzymany po teście zniszczeniowym (etap 2). W pierwszym etapie próbka została zeskanowana w celu odzwierciedlenia początkowego stanu struktury porowej wraz z układem mikropęknięć. Drugi etap reprezentuje próbkę po badaniu geomechanicznym. Dla każdego z etapów przeprowadzono szczegółową analizę struktury porowej. W wyniku proponowanego połączenia wymienionych metod w każdym etapie uzyskano obrazy struktury porów. Próbkę analizowano pod kątem liczby i kierunków propagacji pęknięć i zmian w strukturze porów. Interpretacja jakościowa i ilościowa opierała się na rejestracji zmiany liczby pustek, średnic pęknięć, kątów zapadania i porównaniu struktury porowej pomiędzy stanem początkowym próbki oraz po badaniu geomechanicznym. W 1 etapie (przed testem) największy obiekt (zidentyfikowany jako mikroszczelina) przyjmował objętość powyżej 16 mm3 , po wystawieniu próbki na działanie naprężeń (po zniszczeniu próbki) największy zidentyfikowany obiekt charakteryzował się objętością około 15 razy większą (240 mm3 ). Zidentyfikowane w etapie 2 (po teście wytrzymałościowym) pory są wydłużone (wysokie wartości parametru Elongation), a także nie wykazują znaczącego spłaszczenia (Flatness). Według uzyskanych wyników próbka węgla była podatna na pękanie w określonych kierunkach. Kompleksowe badania wykazały zasadność zastosowania proponowanej metodologii do oceny zmian w strukturze próbki podczas testu wytrzymałościowego.
The study aimed to check the possibility of using computed tomography to observe fractures in coal samples before and after a triaxial compression test (TRX). The paper presents an innovative use of two specialized laboratory techniques: computed tomography and geomechanical triaxial compression test. Geomechanical tests were performed on a TRX-070, GCTS (USA) measuring triaxial system. A full stress-strain characteristic was recorded. Also, during the triaxial compression tests, the P and S wave velocities were measured and dynamic elastic moduli were determined. The results were compared. The sample was analyzed in two stages: CT measurement performed on raw coal sample (stage 1) and after the TRX test which destroyed the sample structure (stage 2). First, the sample was scanned reflecting the initial pores and microcracks system. The final stage represents the sample after the geomechanical test. A detailed pore structure analysis was performed for each of the stages. As a result of the proposed above-mentioned method, images of the pore structure were obtained after each step. The sample was analyzed for crack propagation and changes in the pore structure. The qualitative and quantitative interpretation was based on the determination of the number of voids, crack diameters, collapse angles, and comparison of the pore structure between the initial state of the sample and after the triaxial test. In the first stage (before the test), the largest object (identified as a microcrack) had a volume of approximately 16 mm3 , after the sample was stress-tested (after the sample was destroyed), the largest identified object was about 15 times larger (240 mm3 ). It appeared that the coal sample was prone to fracturing in defined directions. Comprehensive research has demonstrated the legitimacy of using the proposed methodology to evaluate changes in the sample structure during the triaxial test.
Źródło:
Nafta-Gaz; 2021, 77, 1; 3-9
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie rentgenowskiej tomografii komputerowej do porównania metody niskociśnieniowego odlewania przeciwgrawitacyjnego i metody odlewania grawitacyjnego
Application of X-ray computed tomography to compare gravity casting to counter-gravity low-pressure air-melted process
Autorzy:
Krzak, I.
Jaśkowiec, K.
Tchórz, A.
Boroń, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/391421.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
niskociśnieniowe odlewanie przeciwgrawitacyjne (CLA)
rentgenowska tomografia komputerowa (CT)
nieciągłość strukturalna
counter-gravity low-pressure air-melted casting (CLA)
X-ray computed tomography (CT)
structural discontinuities
Opis:
Celem niniejszej pracy była ocena struktury wewnętrznej odlewów zbliżonych do AlSi9Mg (EN AC-43300), wykonanych metodą niskociśnieniowego odlewania przeciwgrawitacyjnego w atmosferze powietrza – CLA (Counter-gravity Low-pressure Air-melted – powietrzne, niskociśnieniowe odlewanie przeciwgrawitacyjne) oraz metodą grawitacyjną. Metodę rentgenowskiej tomografii komputerowej – CT (Computed Tomography) w połączeniu z badaniami strukturalnymi i mechanicznymi, zastosowano do oceny jakości odlewów wytworzonych wyżej wymienionymi technikami. Nieciągłości strukturalne odlewów wykonanych metodą CLA i metodą grawitacyjną zbadano, analizując wyniki prześwietlania przemysłowym tomografem komputerowym firmy Phoenix X-ray. Przykładowo przedstawiono je w postaci wybranych przekrojów (2D) i w wizualizacji przestrzennej (3D). Z uwagi na fakt, że same badania tomograficzne okazały się niewystarczające, dla porównania jakości odlanych próbek różnymi technikami, przeprowadzono badanie mikrostruktury z wykorzystaniem mikroskopu świetlnego oraz wykonano statyczną próbę rozciągania próbek w temperaturze otoczenia.
The purpose of this paper is to evaluate the internal structure of alloys similar to AlSi9Mg (EN AC-43300), made with the counter-gravity low-pressure air-melted process (CLA) and with the gravity casting process. The X-ray computed tomography (CT) examination method was combined with structural and mechanical testing for a qualitative evaluation of the castings produced with these processes. The structural discontinuities in CLA and gravity castings were investigated by studying the imaging made with an industrial- grade CT scanner manufactured by Phoenix X-ray. The examples of images are shown on selected cross-sections (2D) and by 3D visualisation. The CT examination proved to be insufficient for a qualitative comparison of castings produced with different techniques; hence a microstructural examination was carried out under an optical microscope and a static tensile test was completed on the samples at ambient temperature.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 1, 1; 11-21
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wyników badań metrologicznych uzyskanych za pomocą rentgenowskiej tomografii komputerowej i skanera optycznego 3D
Comparison of the results of metrological tests obtained from X-ray computed tomography and optical 3D scanner
Autorzy:
Tchórz, A.
Gil, A.
Powiązania:
https://bibliotekanauki.pl/articles/391594.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
metrologia 3D
skanowanie 3D
rentgenowska tomografia komputerowa (X-ray CT)
optyczny skaner 3D
metrology 3D
3D scanning
X-ray computed tomography (X-ray CT)
optical 3D scanner
Opis:
Istotnym czynnikiem decydującym o jakości wyrobów jest wprowadzenie nowych metod w dziedzinie metrologii technicznej. W pracy przedstawiono metodykę analizy badań metrologicznych uzyskanych za pomocą tomografu komputerowego i skanera optycznego 3D. Urządzenia te umożliwiły uzyskanie wirtualnych obiektów oraz pozwoliły na przeprowadzenie trójwymiarowych analiz przestrzennych. Przedstawiono zasadę działania tych urządzeń oraz przeanalizowano ich możliwości na przykładzie wytypowanych odlewów. Wyniki badań przedstawiono za pomocą określonych wymiarów oraz mapy kolorów na powierzchni modelu. Dokonano oceny dokładności pomiarów w poszczególnych metodach.
The launch of new methods in the technical metrology area is a material factor determining the quality of the products. The paper presents the methodology of analysis of metrological tests conducted with the use of computed tomography and an optical 3D scanner. These devices allowed us to obtain virtual objects and conduct 3D spatial analyses. The paper presents the operating principle of these devices and analyses their capabilities based on selected castings. The results of the tests are presented with the support of determined dimensions and colour maps on the model surface. The accuracy of measurements in individual methods was assessed.
Źródło:
Prace Instytutu Odlewnictwa; 2014, T. 54, nr 4, 4; 63-75
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie rentgenowskiej tomografii komputerowej do wspomagania badań materiałowych odlewów
The use of X-ray computed tomography as a tool in assisting cast material testing
Autorzy:
Krzak, I.
Tchórz, A.
Powiązania:
https://bibliotekanauki.pl/articles/391540.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Odlewnictwa
Tematy:
rentgenowska tomografia komputerowa (CT)
badania defektoskopowe
niskociśnieniowe odlewanie przeciwgrawitacyjne (CLA)
szybkie prototypowanie (RP)
inżynieria odwrotna (RE)
X-ray computed tomography (CT)
flaw detection
counter-gravity low-pressure air-melted casting (CLA)
Rapid Prototyping (RP)
reverse engineering (RE)
Opis:
Technologia wytwarzania odlewów zależna jest od wielu czynników. Warunki techniczne odbioru odlewów określają wymaganą jakość, co jest podstawą do uznania odlewu za dopuszczalny bądź wadliwy. W praktyce produkcja odlewów bez pewnej ilości sztuk wadliwych nie jest możliwa. Dąży się jednak do zminimalizowania strat, stosując różnorodną aparaturę kontrolno-pomiarową. Do sprawdzenia wewnętrznej struktury wyrobu pomocna może być rentgenowska tomografia komputerowa (ang. Computed Tomography – CT). Jest to nowoczesna metoda diagnostyczna, która łączy badania rentgenowskie z zaawansowaną technologią komputerową. Badania tomograficzne umożliwiają bezinwazyjną jakościową ocenę badanego materiału oraz przeprowadzenie zaawansowanych analiz. Jedną z podstawowych zalet rentgenowskiej tomografii CT jest zobrazowanie badanych struktur w trzech wymiarach oraz możliwość wykonania rekonstrukcji przestrzennych. Przedmiotem artykułu jest przybliżenie zasady działania rentgenowskiej tomografii komputerowej oraz omówienie szerokiego jej wykorzystania w różnych dziedzinach nauki, w szczególności w badaniach defektoskopowych, w ilościowych badaniach metalograficznych, w procesie inżynierii odwrotnej (rekonstrukcyjnej) oraz w badaniach metrologicznych. Na wybranych przykładach przedstawiono możliwości rentgenowskiej tomografii komputerowej.
Casting manufacture depends on many factors. Technical specifications determine the required quality, which is essential for casting acceptance or rejection. Practice shows that making castings without defects is simply not possible. However, the aim is to minimize rejects owing to the use of diverse instruments for measurements and control. A tool which may be helpful in checking the internal structure of products is the X-ray computed tomography (CT). CT is a modern diagnostic method that combines X-ray examinations with advanced computer technology. Tomographic studies allow non-destructive qualitative assessment of the test material combined with advanced analysis. One of the main advantages of the X-ray computed tomography is imaging of the examined structure in three dimensions and the ability to perform spatial reconstruction. The aim of this article is to describe the principle operation of X-ray computed tomography and offer extensive discussion of its use in various fields of science, in particular to defect detection, quantitative metallographic tests, the process of reverse engineering (reconstruction) and metrological studies. Selected examples were used to show the potential offered by this technique.
Źródło:
Prace Instytutu Odlewnictwa; 2015, T. 55, nr 3, 3; 33-42
1899-2439
Pojawia się w:
Prace Instytutu Odlewnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obrazowanie wybranych własności utworów solnych za pomocą różnych metod badawczych
Defining selected salt rocks properties using various research methods
Autorzy:
Cebulski, D.
Urbaniec, A.
Kasprzyk, K.
Powiązania:
https://bibliotekanauki.pl/articles/1835436.pdf
Data publikacji:
2017
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
sól kamienna
halit
komputerowa tomografia rentgenowska
skaningowy mikroskop elektronowy
salt rocks
halite
X-ray computer tomography
scanning electron microscopy
Opis:
Artykuł przedstawia wyniki przeprowadzonych analiz materiału rdzeniowego z wybranych utworów solnych, reprezentujących cechsztyńską i mioceńską formację solonośną. W celu określenia charakterystycznych parametrów i własności badanych skał solnych wykorzystano następujące metody: rentgenowską tomografię komputerową (CT), analizę w skaningowym mikroskopie elektronowym (SEM), analityczne oznaczenia składu chemicznego, fluorescencję rentgenowską (XRF) oraz dyfrakcję rentgenowską (XRD). Zastosowane metody badawcze pozwoliły określić zróżnicowanie najbardziej charakterystycznych cech analizowanych utworów.
The article presents the results of well core analysis from salt rocks, representing the Zechstein and the Miocene salt formations. The following methods were applied in order to determine the characteristic parameters and properties of the analyzed salt rock: X-ray computer tomography (CT), scanning electron microscopy (SEM), methods of the chemistry identification, X-ray fluorescence (XRF) and X-ray diffraction (XRD). The applied research methods helped to identify the diversity of the most characteristic features of the tested rocks.
Źródło:
Nafta-Gaz; 2017, 73, 4; 227-235
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa tomograficznych systemów komputerowych
Design of computer tomography systems
Autorzy:
Budzik, G.
Dziubek, T.
Turek, P.
Powiązania:
https://bibliotekanauki.pl/articles/135976.pdf
Data publikacji:
2015
Wydawca:
Wyższa Szkoła Techniczno-Ekonomiczna w Szczecinie
Tematy:
tomografia komputerowa
gantra
detektor
lampa rentgenowska
computer tomography
gantry
detector
X-ray source
Opis:
Wstęp i cel: W wyniku wzrastającej potrzeby uzyskania danych diagnostycznych wysokiej jakości, budowa tomografów komputerowych ulegała ciągłym przeobrażeniom. Mimo wprowadzeniu nowych rozwiązań, nadal źródłem promieniowania jest lampa rentgenowska, a detektory rejestrują stopień absorpcji promieniowania. Artykuł przedstawia podstawowe komponenty, wchodzących w skład komputerowych systemów tomograficznych. Materiał i metody: W artykule przedstawiono podstawowe komponenty wchodzące w skład komputerowego systemu tomograficznego, które mają bezpośredni wpływ na jakość uzyskanych danych diagnostycznych. Wyniki: Wysokie napięcie zwiększa zdolność wiązki do lepszej penetracji struktur, przez które przechodzi. W ten sposób redukowana jest dawka promieniowania. Dodatkowo wysokie napięcie, zmniejsza obciążenie lampy w wyniku zmniejszenia natężenia. Zabieg ten zwiększa żywotność lampy rentgenowskiej. Czułość detektorów ksenonowych i półprzewodnikowych jest bardzo zbliżona. Detektory półprzewodnikowe mają wysoką liczbę atomową i dużą gęstość w porównaniu do gazów, posiadają tym samym wysoki współczynnik absorpcji. Wniosek: W ramach prowadzonych badań, niezwykle istotne jest, aby zmniejszyć dawkę promieniowania, której podany jest pacjent podczas skanowania. Skrócenie czasu pomiaru na tomografie komputerowym w wyniku zastosowania pierścieni ślizgowych, pozwoliło częściowo rozwiązać ten problem. Mimo wszystko nadal nie skonstruowano skanera, który zupełnie nie zagrażałby zdrowiu pacjenta, a jednocześnie wykonywałby pomiary z należyta dokładnością.
Introduction and aim: As a result of the increasing high-quality diagnostic data, the construction of computer tomography constantly changes. Despite of it, X-ray tube is still a source of radiation and detectors collect information regarding the degree to which each anatomic structure attenuated the beam. The article presents the basic components included in computer tomography systems. Material and methods: The article presents the basic components included in the computerized topographic system, which have a direct impact on the quality of the obtained diagnostic data. Results: The high voltage enhances the ability of the beam to better penetrate the structures through which it passes. What is more the radiation dose is reduced. In addition, high voltage, reduces the load on the lamp by reducing the intensity. This treatment increases the life of the X-ray tube. The sensitivity of xenon and solid -state detectors is very similar. Solid - state detectors have high atomic number and high density compared to gases, so they have high absorption efficiency. Conclusion: It is very important to reduce the radiation dose to which the patient is exposure. Slip rings reduced the time of measurement, allowed partly solve this problem. Actually scientist works on construction CT scanner which allow increase accuracy measurements and no influence on health of the patient.
Źródło:
Problemy Nauk Stosowanych; 2015, 3; 5-14
2300-6110
Pojawia się w:
Problemy Nauk Stosowanych
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Possibility of Applying Spatial 3D Imaging Using X-Ray Computed Tomography Reconstruction Methods for Quantitative Analysis of Multiphase Materials
Rentgenowska analiza ilościowa materiałów wielofazowych z wykorzystaniem przestrzennego obrazowania (3D) przy użyciu metod rekonstrukcji tomografii komputerowej
Autorzy:
Matysik, P.
Chojnacki, M.
Jóźwiak, S.
Czujko, T.
Lipiński, S.
Powiązania:
https://bibliotekanauki.pl/articles/353166.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computed tomography
electron microscopy
X-ray diffraction
stereology
phase analysis
quantitative research
tomografia komputerowa
mikroskopia elektronowa
dyfrakcja rentgenowska
stereologia
analiza fazy
badania ilościowe
Opis:
In this paper the possibility of using X-ray computed tomography (CT) in quantitative metallographic studies of homogeneous and composite materials is presented. Samples of spheroidal cast iron, Fe-Ti powder mixture compact and epoxy composite reinforced with glass fibers, were subjected to comparative structural tests. Volume fractions of each of the phase structure components were determined by conventional methods with the use of a scanning electron microscopy (SEM) and X-ray diffraction (XRD) quantitative analysis methods. These results were compared with those obtained by the method of spatial analysis of the reconstructed CT image. Based on the comparative analysis, taking into account the selectivity of data verification methods and the accuracy of the obtained results, the authors conclude that the method of computed tomography is suitable for quantitative analysis of several types of structural materials.
W pracy przedstawiono możliwość wykorzystania rentgenowskiej tomografii komputerowej (CT) w ilościowych badaniach metalograficznych materiałów jednorodnych oraz kompozytowych. Badaniom porównawczym poddano wypraskę mieszaniny proszkowej Fe – Ti, żeliwo sferoidalne, a także kompozyt epoksydowy zbrojony włóknami szklanymi. Udział objętościowy poszczególnych składników strukturalnych określano za pomocą klasycznych metod stereologicznych z wykorzystaniem skaningowej mikroskopii elektronowej (SEM) oraz metodami rentgenowskiej analizy ilościowej (XRD). Uzyskane typowymi metodykami wyniki porównano z rezultatami otrzymanymi za pomocą metody przestrzennej analizy obrazu tomografii komputerowej. Na podstawie przeprowadzonych analiz, biorąc pod uwagę selektywny sposób weryfikacji danych oraz dokładność uzyskiwanych wyników, można stwierdzić przydatność wykorzystania metody tomografii komputerowej, w obszarze ilościowej analizy strukturalnej szerokiego spektrum materiałów konstrukcyjnych.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2663-2670
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tomografia komputerowa w pomiarach geometrycznych 3D
Computed tomography in 3D geometrical measurements
Autorzy:
Ratajczyk, E.
Powiązania:
https://bibliotekanauki.pl/articles/151191.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
tomografia komputerowa-TC
lampa rentgenowska
promieniowanie X
współrzędnościowa technika pomiarowa
computed tomography CT
detector
coordinate measuring systems
X-rays radiations
rotary tables
X-ray tube
Opis:
Istota pomiarów tomograficznych opartych na promieniowaniu rentgenowskim X. Budowa tomografów - główne zespoły i ich funkcje. Kalibracja tomografów. Prezentacja modelu tomografu opracowanego w Instytucie Metrologii i Inżynierii Biomedycznej.
Computed tomography (CT), after its dynamical development for medical requirements recently starts to appear in an area of industrial applications. It enables not only to determine dimensions of objects made of metal, plastics and different kinds of composed materials but also to defect internal defects of the material. This paper describes concepts of CT measurements. The main construction units of tomographs are characterized and the examples of tomographs of different firms and their applications are given. The accuracy and calibration problems are also shortly discussed. At the and the concepts of home - made computed tomograph for industrial applications are also presented.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 2, 2; 220-223
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies