Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "removal nitrogen" wg kryterium: Temat


Tytuł:
Previous investigations on the influence of oxygen concentration on nitrogen removal efficiency in a hybrid moving bed sequencing batch biofilm reactor (MBSBBR)
Oczyszczanie ścieków w reaktorach ze złożem ruchomym - możliwości technologiczne
Autorzy:
Żubrowska-Sudoł, M.
Podedworka, J.
Powiązania:
https://bibliotekanauki.pl/articles/396466.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
reaktor sekwencyjny
dissolved oxygen concentration
MBSBBR
nitrogen removal
Opis:
The paper presents preliminary results of the research on the efficiency nitrogen removal in a hybrid sequencing batch reactor MBSBBR operating at low dissolved oxygen (DO) concentration ranging between 0,5 and 2 mg O_2/l. The study was carried out in a pilot scale model of SBR with a total volume of 35 liters, filled with carrier media up to the volumetric ratio 7,5 % of the fill volume. A high efficiency of COD removal, obtained at DO concentration of 0,5--1,0 mg O_2/l, creates possibilities for a substantial reduction of exploatation costs for wastewater treatment plants on MBSBBR reactors. The analysis of the influence of a preset DO level on nitrogen transformation processes was found that together with an increase of DO concentration in the aerobic phases of the cycle an increase of the nitrification rate and decrease of the simultaneous denitrification rate can be observed. The highest efficiency of nitrogen compounds removal was reached at DO concentration of 1,0--1,5 mg O_2/l. The conducted survey has confirmed that a DO concentration is one of the criterion-parameters for the process of simultaneous denitrification in aerobic phases.
W artykule przedstawiono wyniki badań nad wpływem stężenia tlenu na efektywność usuwania azotu w reaktorze sekwencyjnym ze złożem ruchomym (MBSBBR). Eksperyment przeprowadzono w laboratoryjnym modelu reaktora typu SBR o całkowitej objętości 35 litrów dla stężenia tlenu w zakresie 0,5---3,0 mg O_2/l. Wypełnienie stanowiło 7,5% czynnej objętości reaktora. Uzyskana dla stężenia tlenu 0,5--1,0 mg O_2/l wysoka efektywność usuwania związków organicznych (ChZT) wskazuje na możliwość znaczącego obniżenia kosztów eksploatacyjnych małych oczyszczalni ścieków typu MBSBBR. Analiza wpływu stężenia tlenu na procesy przekształcania azotu wykazała, że wraz ze wzrostem poziomu tego wskaźnika rosła wydajność procesu nitryfikacji, ale jednocześnie malała wydajność procesu symultanicznej denitryfikacji w fazach tlenowych cyklu. Najwyższą efektywność eliminacji azotu uzyskano dla stężenia tlenu w zakresie 1,0--1,5 mg O_2/l. Przeprowadzone badania wykazały, że stężenie tlenu jest jednym z kryterialnych parametrów procesu symultanicznej denitryfikacji w fazach tlenowych.
Źródło:
Civil and Environmental Engineering Reports; 2007, 2; 129-143
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of biogens from synthetic wastewater by microalgae
Autorzy:
Zabochnicka-Świątek, M.
Malińska, K.
Krzywonos, M.
Powiązania:
https://bibliotekanauki.pl/articles/206894.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
algae
microorganisms
phosphorus removal
nitrogen removal
synthetic wastewater
Chlorella vulgaris
biogens
glony
mikroorganizmy
usuwanie azotu
usuwanie fosforu
ścieki syntetyczne
biogeny
Opis:
Removal of biogens (P, N) from synthetic wastewater by microalgae Chlorella vulgaris was investigated. The study was carried out under static conditions (batch tests). Significant differences were found in the removal of nutrients by algae. The removal of biogens was >50% for ammonium ions and >80% for nitrates and phosphates. N and P removal through assimilation by microalgal C. vulgaris species can be considered an ecological alternative for current methods applied for removal of these substances from wastewater. It seems that using algae for N and P removal from wastewater can be affordable in comparison to other methods. The efficiency of biogens removal depends on the type of a biogen to be removed and the concentration of N and P in solutions. Optimization of N:P ratio can have some positive influence on the removal of biogens from wastewater by C. vulgaris.
Źródło:
Environment Protection Engineering; 2014, 40, 2; 87-104
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Phytoremediation of urea fertilizer factory wastewater by teak (Tectona grandis)
Autorzy:
Yavari, S.
Malakahmad, A.
Sapari, N. B.
Powiązania:
https://bibliotekanauki.pl/articles/207362.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phytoremediation
nitrogen removal
urea
Tecona grandis
sludge
fitoremediacja
usuwanie azotu
mocznik
ścieki
Opis:
Urea manufacturing discharge contains a high load of nitrogen, a pollutant which needs advanced technologies to be reduced to desirable levels. However, these advanced technologies are expensive due to the complex process and cost of chemicals and maintenance. Phytoremediation has been recently considered for N removal from various wastewaters. However, the common phytoremediation plants (reeds and grasses) are not able to remove N effectively due to the recyclable nature of N through decomposition processes. Therefore, they require periodic harvestings which impose a high cost on system. In this study, the growth and phytoremediation potential of teak (Tectona grandis), a tropical timber plant, to treat the urea manufacturing wastewater was evaluated. Eight month old teak seedlings received 4 different concentrations of N in bench-scale constructed wetlands every 4 days for 8 weeks. The solution volumes supplied to each container and plant biomass, N recovery, and tissue nutrient concentration were measured. Teak plants showed an escalation in wastewater N uptake with increasing amount of supplied N. Total dry weight was positively correlated with total N supplied. Teak seedlings showed a considerable potential for removing nitrogen when they were supplied with up to 5 g N per pot volume (4 dm3) during a two-month experiment.
Źródło:
Environment Protection Engineering; 2017, 43, 4; 5-15
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comprehensive analysis of soil nitrogen removal by catch crops based on growth and water use
Autorzy:
Yasutake, D.
Kondo, K.
Yamane, S.
Kitano, M.
Mori, M.
Fujiwara, T.
Powiązania:
https://bibliotekanauki.pl/articles/25238.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
comprehensive analysis
soil
nitrogen removal
catch crop
growth analysis
corn
evapotranspiration
greenhouse
water use
plant density
Źródło:
International Agrophysics; 2016, 30, 3
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological stability of water in water distribution systems. The effect of water treatment trials
Autorzy:
Wolska, M.
Powiązania:
https://bibliotekanauki.pl/articles/206902.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
carbon
groundwater
microorganisms
nitrogen removal
organic carbon
surface waters
water aeration
water distribution systems
water supply systems
biological stability
inorganic nitrogen
uzdatnianie wody
węgiel
wody gruntowe
mikroorganizmy
usuwanie azotu
węgiel organiczny
wody powierzchniowe
napowietrzanie wody
systemy dystrybucji wody
wodociągi
stabilność biologiczna
stężenie dwutlenku węgla
azot nieorganiczny
Opis:
Research into the removal efficiency of biogenic substances, necessary for the growth of heterotrophic microorganisms, was carried out for the following water treatment trials: surface water, infiltrative water and mixed surface water after microsieving with aerated underground water. The results have shown that the efficiency of removal of organic substances, independently of the type of treated water, increased along with the organic carbon concentrations in raw water. The average effectiveness of phosphate removal was: 92.1%, 88.8% and 83.7% for surface, infiltrative and mixed water, respectively. In all analyzed systems, presence of phosphates was an limiting factor for the regrowth of microorganisms in the distribution system. In none of the water treatment trials, effective removal of inorganic nitrogen has been recorded.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 147-157
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Transformation Analysis of Carbon and Nitrogen Compounds in Wastewater Treated in a Vertical Biofilter
Autorzy:
Wawrentowicz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2028141.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD removal
nitrogen form
biofilter
Opis:
Biofilter technology for wastewater treatment is relatively complex and is gaining more interest. However, it should be emphasised that various aerobic conditions may occur in biological filter beds, which depend primarily on the velocity of wastewater flow through the bed. Therefore, it is often difficult to precisely determine the transformations of carbon and nitrogen compounds that occur during wastewater treatment on these types of filter beds. This study investigated the effectiveness of the filter bed and analysed the extent of the transformation of carbon and nitrogen compounds in the range of filtration velocities from $0.02$ to $0.60 m•h^{-1}$. The study was conducted under laboratory conditions, and model wastewater was prepared on the basis of sodium acetate, ammonium chloride, potassium nitrate and potassium dihydrogen phosphate. The model wastewater was prepared with parameters corresponding to those of the treated wastewater. The experiment showed that anaerobic and aerobic conditions occurred in the biological filter bed at filtration velocities of up to $0.16 m•h^{-1}$. Above this velocity, aerobic conditions prevailed in the biological filter bed.
Źródło:
Journal of Ecological Engineering; 2021, 22, 11; 215-222
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowe trendy w usuwaniu azotu amonowego ze ścieków: nitrytacja – anammox w niskiej temperaturze
new trends in ammonia nitrogen removal from wastewater: nitritation – anammox at low temperature
Autorzy:
Tomaszewski, M.
Cema, G.
Ziembińska-Buczyńska, A.
Powiązania:
https://bibliotekanauki.pl/articles/400316.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
nitrytacja–anammox
usuwanie azotu amonowego
oczyszczanie ścieków
nitritation–anammox
ammonia nitrogen removal
wastewater treatment
Opis:
Proces częściowej nitryfikacji (nitrytacji) – anammox (beztlenowego utleniania azotu amonowego) znajduje coraz szersze zastosowanie w oczyszczaniu ścieków o wysokim ładunku azotu amonowego i wysokiej temperaturze (25–40°C). Podyktowane jest to optymalną temperaturą rozwoju bakterii anammox, która mieści się w zakresie od 30 do 40°C. Ze względu na korzyści płynące z wykorzystania procesu anammox do oczyszczania ścieków komunalnych, których temperatura znacznie odbiega od optymalnej dla procesu, coraz więcej uwagi poświęca się badaniom nad możliwościami efektywnego prowadzenia procesu nitrytacji – anammox w niższej temperaturze (10–20°C). W porównaniu do tradycyjnego systemu nitryfikacji – denitryfikacji, proces nitrytacji – anammox cechuje się niższym zapotrzebowaniem na tlen, niższym przyrostem osadu nadmiernego oraz brakiem zapotrzebowania na źródło węgla organicznego, co przekłada się na znaczne obniżenie kosztów eksploatacyjnych. W prezentowanej pracy dokonano przeglądu najnowszych badań i osiągnięć dotyczących zastosowania procesu nitrytacji – anammox w niskich temperaturach. Wykazały one, że możliwe jest skuteczne usuwanie azotu amonowego ze ścieków komunalnych w temperaturze 15°C w skali pilotażowej, a nawet 12°C w skali laboratoryjnej. Najlepsze rezultaty osiągane są dzięki zastosowaniu reaktorów sekwencyjnych i/lub ze złożem ruchomym, w których biomasa występuje w formie granul i/lub biofilmu, a także kombinacje tych technologii. Badania oparte na biologii molekularnej sugerują natomiast, że największe zdolności adaptacyjne do niskiej temperatury wykazują bakterie anammox z rodzaju Candidatus Brocadia. W dalszym ciągu wyzwaniem pozostaje jednak utrzymanie stabilnego procesu nitrytacji – anammox w temperaturze 10°C oraz sposób i czas adaptacji biomasy.
Partial nitrification (nitritation) – anammox (anaerobic ammonia oxidation) process is increasingly used to treat wastewater, characterized by a high nitrogen content and high temperature (25–40°C). It is connected with the optimal temperature of anammox bacteria, which is at the range between 30 and 40°C. Mainstream application of anammox for the municipal wastewater, characterized by lower temperature seems to be one of the most challenging, but profitable process. Thenceforth, the research performed in the field of the nitritation – anammox at low temperature (10–20°C) become more and more intense. Compared with the conventional nitrification – denitrification system, nitritation – anammox reduces oxygen demand, eliminates the need for organic carbon source and produces less excess sludge. As a result, it allows to a significant cost reduction. This paper reviews the most important and recent information in the field of nitritation – anammox process at low temperature. Effective nitrogen removal from the municipal wastewater was demonstrated at 15°C in a pilot scale and at 12°C in a laboratory scale reactor. The best performance is achieved in sequencing batch reactors and moving bed reactors with biofilm or granular biomass, as well as combinations of these technologies. Molecular biology studies shows that anammox bacteria of the genus Candidatus Brocadia may have the biggest predispositions to adapt to low temperature. However, temperature about 10°C, time and method of biomass adaptation are still the main challenges for stable and common nitritation – anammox process.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 2; 175-179
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Efficiency of Nitrogen Compounds Removal in Wastewater Treatment Plant
Ocena efektywności pracy oczyszczalni ścieków o RLM 45000
Autorzy:
Suchowska-Kisielewicz, M.
Sieciechowicz, A.
Sadecka, Z.
Powiązania:
https://bibliotekanauki.pl/articles/396351.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
nitrogen removal
BOD5/TKN ratio
wastewater temperature
usuwanie związków azotu
BZT5/TKN
temperatura ścieków
Opis:
In sewage treatment plants for removing nitrogen compounds are used biological processes of nitrification and denitrification. The parameters determining the efficiency of biological processes of nitrogen removal are organic carbon ratio (BOD5) to total Kjeldahl nitrogen (TKN), temperature and pH. The impact of these parameters on the operation of the sewage treatment plant with an RLM of 45,000 based on operational data from the period 2011-2013 has been assessed. The efficiency of removing nitrogen compounds from sewage in the analysed treatment plant depended on the temperature of sewage and the quotient BOD5/TKN. Even at the optimal ranges of BOD5/TKN ratio temperature at 10°C nitrogen concentration in the treated wastewater was about 3 times higher than the limit value, and the removal efficiency of nitrogen varied between about 30 to 60%.
W oczyszczalniach mechaniczno-biologicznych do usuwania związków azotu wykorzystuje się biologiczne procesy nitryfikacji i denitryfikacji. Usuwanie fosforu odbywa się przy wykorzystaniu metod biologicznych lub chemicznych. Sprawność procesów biologicznych wymaga odmiennych warunków środowiskowych tzn. tlenowych dla nitryfikacji, a beztlenowych dla denitryfikacji, czy tez warunków beztlenowo-tlenowych dla defosfatacji biologicznej. Parametrami decydującymi o sprawności procesów biologicznych usuwania azotu są: stosunek węgla organicznego (BZT5) do ogólnego azotu Kjeldahla (TKN), temperatura i odczyn środowiska. Wpływ tych parametrów na pracę oczyszczalni o RLM 45 000 oceniono na podstawie danych eksploatacyjnych z okresu 2011-2013. Efektywność usuwania związków azotu ze ścieków w analizowanej oczyszczalni zależała od temperatury ścieków oraz ilorazu BZT5/TKN Zmienne wartości ilorazu BZT5/TKN w zakresie od 2,7 do 8,1, wpływały na uzyskiwaną efektywność zarówno procesu nitryfikacji, jak i denitryfikacji. Nawet przy optymalnych zakresach BZT5/TKN w temperaturze poniżej 10°C stężenia azotu w ściekach oczyszczonych były nawet o około 3-krotnie wyższe od wartości dopuszczalnej, ze sprawnością usuwania azotu w zakresie od 30 do 60%.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(3); 5-16
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie zeolitu do usuwania jonów azotu amonowego z cieczy osadowej
Use of zeolite for removal of ammonium nitrogen from reject water
Autorzy:
Sperczyńska, E.
Powiązania:
https://bibliotekanauki.pl/articles/297762.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
ammonia nitrogen removal
reject water
zeolite
usuwanie azotu amonowego
ciecze osadowe
zeolity
Opis:
Research work on the possibilities of adsorption/ion exchange processes use for ammonium nitrogen removal form reject water was performed. The aim of the study was to evaluate the effectiveness of ammonium nitrogen removal from reject water separated after methane digestion. Zeolites were used from ammonium nitrogen removal. Reject water was taken from municipal wastewater treatment plant of PE over 100 000. They were sampled after mechanical dewatering of digested sewage sludge. High concentrations of biogens were stated in the reject water: nitrogen concentration was equal to 893.4 mg N-NH4+/dm3, whereas phosphorus was equal to 40.8 mg P-PO43-/dm3. COD value was 276 g O2/dm3. Reject water had brown colour and alkaline pH (pH = 7.92). Turbidity of reject water was equal to 94.1 NTU. Removal of ammonium nitrogen was performed on zeolite bed of 50 cm high and with diameter of 3.4 cm. At first model reject water was introduced into the bed. Concentration of ammonium nitrogen in model reject water was equal to 100 mg N-NH4+/dm3 (filtration velocity 5.0 m/h). Removal efficiency of ammonium nitrogen was in the range 80÷90%. Simultaneously increase in turbidity of treated model water was observed. Further experiment were performed with reject water taken from wastewater treatment plant. Filtration velocities were equal to 3.4 and 12.7 m/h. At higher filtration velocity ammonium nitrogen removal was in the range of 20 and 52%. For the last three samples removal efficiency has set at level of 30%, As filtration velocity was lower removal efficiency of ammonium nitrogen increased to 30÷70% in subsequent portions of filtrate. Stabile results were obtained for the fifth portion of filtrate. Removal of ammonium nitrogen from reject water on zeolite beds depends on filtration velocity. As filtration velocity decreases removal efficiency of ammonium nitrogen increases. Stabile results of ammonium nitrogen removal efficiency from reject water by zeolite beds water at level of 30%. It must be emphasised that parameters of reject water differed during the experiment. As concentration of ammonium nitrogen decreased alkalinity, pH and turbidity increased. Turbidity increase was especially visible at low filtration velocities. The same trend was observed in the case of COD.
Badania prowadzono w kierunku określenia możliwości zastosowania procesu adsorpcji/ wymiany jonowej na zeolitach w celu usunięcia azotu amonowego z cieczy osadowych. Do badań wykorzystano ciecze osadowe pochodzące z odwadniania przefermentowanych komunalnych osadów ściekowych z oczyszczalni ścieków o RLM powyżej 100 000. Ciecze osadowe charakteryzowały się bardzo wysokimi stężeniami związków biogennych: azotu (893,4 mg N-NH4+/dm3) oraz fosforu (40,8 mg P-PO43-/dm3). Ponadto ciecze wyróżniały się wysoką brunatną barwą, odczynem zasadowym (pH = 7,92) oraz wysoką mętnością (94,1 NTU). Usuwanie azotu amonowego na złożu zeolitowym prawdzono w pierwszej kolejności dla cieczy modelowej o stężeniu około 100 mg N-NH4+/dm3. Uzyskano od 80 do 90% efektywność usunięcia N-NH4+. Jednocześnie zaobserwowano zwiększenie mętności filtratu. Następnie określono wpływ prędkości filtracji na efektywność usuwania jonów amonowych z cieczy osadowych. Badania prowadzono dla vf = 3,4 oraz 12,7 m/h. Przy wyższej prędkości filtracji uzyskano zmniejszenie zawartości azotu amonowego od 20 do 52%, natomiast przy niższej od 30 do 70% w kolejnych porcjach filtratu. Usunięcie azotu amonowego z cieczy osadowych w warunkach przepływowych jest uzależnione od prędkości filtracji; im mniejsza prędkość filtracji, tym bardziej zwiększa się efektywność usunięcia azotu amonowego. Uzyskano możliwość stabilnego usunięcia azotu amonowego z cieczy osadowych na złożu zeolitowym na poziomie nie większym niż 30%.
Źródło:
Inżynieria i Ochrona Środowiska; 2016, 19, 3; 391-399
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szybkość usuwania związków azotu i fosforu podczas faz procesowych reaktora SBR
Removal rate of nitrogen and phosphorus compounds during SBR process phases
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/400622.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
szybkość usuwania związków azotu
szybkość usuwania związków fosforu
zewnętrzne źródła węgla
gliceryna
reaktor SBR
nitrogen removal rate
phosphorus removal rate
external carbon sources
glycerin
SBR reactor
Opis:
W artykule przedstawiono szybkości usuwania związków azotu i fosforu ze ścieków z zastosowaniem gliceryny jako zewnętrznego źródła węgla. Badania prowadzono podczas procesu oczyszczania ścieków komunalnych w dwóch niezależnych komorach osadu czynnego typu SBR. Do jednej z komór dodano glicerynę jako źródło łatwo przyswajalnych związków organicznych. Przeprowadzone badania wykazały, że zastosowanie gliceryny jako zewnętrzne źródło węgla podczas oczyszczania ścieków wpłynęło pozytywnie na obniżenie stężeń form azotu i fosforu. Dodatek gliceryny przyczynił się do zwiększenia szybkości usuwania azotanów w procesie denitryfikacji oraz do przyśpieszenia usuwania azotu amonowego w procesie nitryfikacji, natomiast nie stwierdzono istotnych zależności między szybkością usuwania związków fosforu a dodatkiem zewnętrznego źródła węgla w formie gliceryny.
The article presents the results pertaining to the effectiveness of nitrogen removal from wastewater using glycerin as an external carbon source. The study was conducted during the process of municipal wastewater treatment in two independent chambers of activated sludge SBR. Glycerin was added to one of the chambers as a source of easily available organic compounds. The study showed that the use of glycerin as an external carbon source to wastewater treatment resulted in a positive influence on the reduction of nitrogen and phosphorus forms. The addition of glycerin contributed to an increase in nitrate removal rates in the denitrification process and to the accelerated removal of ammonium nitrate in the nitrification process; however, no significant relationship was found between the rate of phosphorus compounds removal and the addition of external carbon source in the form of glycerol.
Źródło:
Inżynieria Ekologiczna; 2017, 18, 6; 36-40
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nitrogen removal from fish farms water by Lemna minor and Wolffia arrhiza
Usuwanie azotu z wody gospodarstw rybnych z wykorzystaniem rzęsy drobnej i wolfii bezkorzeniowej
Autorzy:
Sabliy, L.
Konontsev, S.
Grokhovska, J.
Widomski, M. K.
Łagód, G.
Powiązania:
https://bibliotekanauki.pl/articles/126504.pdf
Data publikacji:
2016
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
pollution of water in fish farms
nitrogen removal
Lemnoideae in water treatment
zanieczyszczenia wody gospodarstw rybnych
usuwanie azotu
Lemnoideae w oczyszczaniu wody
Opis:
It is extremely important for the productive fish farming with closed water systems to treat the water to the level allowing its reuse for fish production. This paper presents studies considering the possibility of water embryophyte application to assimilation of pollutants (mainly nitrogen compounds) solute in water of recirculation systems in fish farms. The results of experimental studies covering ammonium nitrogen removal from polluted water of fish farms by the tested Lemnoideae representatives (Lemna minor and Wolffia arrhiza) were presented. The obtained results confirmed the usefulness of phytoreactors application in wastewater treatment plants in fish farms.
Dla wydajnej hodowli ryb w układach z zamkniętym systemem obiegu wodnego niezwykle ważne jest właściwe oczyszczanie wody do poziomu, który pozwala na jej ponowne wykorzystanie. W opracowaniu przedstawiono możliwość zastosowania wyższych roślin wodnych do asymilacji zanieczyszczeń rozpuszczonych w wodzie, głównie związków azotu. Zaprezentowane wyniki badań eksperymentalnych dotyczą usuwania azotu amonowego z zanieczyszczonej wody gospodarstw rybnych przedstawicielami rzęsowych (Lemnoideae) rzęsą drobną i wolfią bezkorzeniową. Wyniki te potwierdzają zasadność wykorzystania fitoreaktorów w obiektach oczyszczalni gospodarstw hodowli ryb.
Źródło:
Proceedings of ECOpole; 2016, 10, 2; 499-504
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of electric current density on specific denitrification rate of and nitrogen removal rate in electrochemical and electrobiological rotating contactor
Wpływ gęstości prądu elektrycznego na właściwą szybkość denitryfikacji i na szybkość usuwania azotu w elektrochemicznym i elektrobiologicznym złożu obrotowym
Autorzy:
Rodziewicz, Joanna
Janczukowicz, Wojciech
Mielcarek, Artur
Bryszewski, Kamil
Powiązania:
https://bibliotekanauki.pl/articles/1845362.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electric current density
rotating electrochemical disk contactor
rotating electrobiological disk contactor
specific denitrification rate
nitrogen removal rate
gęstość prądu elektrycznego
obrotowy elektrochemiczny stycznik dyskowy
obrotowy elektrobiologiczny stycznik dyskowy
określony stopień denitryfikacji
szybkość usuwania azotu
Opis:
This study aimed to determine the influence of the electric current density on the rate of nitrogen compounds removal (rN) and the specific rate of denitrification (rD) in a rotating electrochemical disk contractor (RECDC) and a rotating electro-biological disk contactor (REBDC). In REBDC and RECDC, the cathode consisted of disks with immobilized biomass and disk, from which biofilm was periodically removed, respectively. An aluminum anode was mounted in contactor chambers. The study was conducted using synthetic wastewater with characteristics similar to wastewater from soilless cultivation of tomatoes. The first stage of the study determined rN and rD in the RECDC. The second stage determined rN and rD in the REBDC. Four hydraulic retention times (HRT) were tested: 4 h, 8 h, 12 h, and 24 h, with electric current densities of 0.63 A/m2, 1.25 A/m2, 2.50 A/m2, 5.00 A/m2, and 10.00 A/m2. In RECDC, a linear dependency was observed between rN and current density in the examined HRTs, whereas in REBDC, a logarithmic dependency was confirmed between rN and current density. In both contactors, an exponential dependency was observed between rD and current density. The specific rate of denitrification decreased when the current density and HRT were increased. The study showed that, in both contactors, the rate of total nitrogen removal increased when the current density was increased and the HRT was decreased.
Celem pracy było określenie wpływu gęstości prądu na szybkość usuwania związków azotu (rN) i na specyficzną szybkość procesu denitryfikacji (rD) w elektrochemicznym tarczowym złożu obrotowym (RECDC) i elektrobiologicznym tarczowym złożu obrotowym (REBDC). W elektrochemicznym tarczowym złożu obrotowym (RECDC) i elektrobiologicznym tarczowym złożu obrotowym (REBDC) katodę stanowiły odpowiednio tarcze pokryte błoną biologiczną i tarcze z których okresowo usuwano błonę biologiczną. Aluminowa anoda była umieszczona w zbiornikach złoża. Badania przeprowadzono na ściekach o wskaźnikach fizykochemicznych podobnych do ścieków z bezglebowej uprawy pomidorów. W pierwszym etapie badań określono wartości rN and rD w RECDC podczas gdy w drugim w REBDC. Zastosowano cztery wartości hydraulicznego czasu zatrzymania (HRT): 4 h, 8 h, 12 h and 24 h dla następujących gęstości prądu: 0.63 A/m2, 1.25 A/m2, 2.50 A/m2, 5.00 A/m2 and 10.00 A/m2. W elektrochemicznym złożu zaobserwowano liniową zależność pomiędzy rN i gęstością prądu, podczas gdy w złożu elektrobiologicznym zależność logarytmiczną. Dla obu złóż stwierdzono wykładniczą zależność pomiędzy rD i gęstością prądu. Specyficzną szybkość procesu denitryfikacji malała wraz ze wzrostem gęstości prądu i HRT. Badania pokazały, że w obu złożach, elektrochemicznym i elektrobiologicznym szybkość usuwania związków azotu obniżała się wraz ze wzrostem gęstości prądu i obniżaniem HRT.
Źródło:
Archives of Environmental Protection; 2020, 46, 4; 23-32
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of natural zeolite for intensification of municipal wastewater treatment
Autorzy:
Ospanov, O.
Myrzakhmetov, M.
Andraka, D.
Dzienis, L.
Powiązania:
https://bibliotekanauki.pl/articles/123094.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
natural zeolite
hybrid systems
attached-suspended growth systems
wastewater treatment
nitrogen removal
Opis:
The purpose of this research was to prove that a hybrid system including activated sludge and biofilm attached to carrying media (natural zeolite) can improve the efficiency of municipal wastewater treatment. The study was performed using a pilot-scale plant installed on Almaty Wastewater Treatment Plant (Kazakhstan) and treated sewage after preliminary mechanical treatment. The investigations were conducted in 2 stages: with installation without packing media (activated sludge only) and packed with zeolite from Chankanaysky field (activated sludge and biofilm). The results from the study showed a significant improvement of treatment efficiency for all examined parameters (BOD5, COD, suspended solids, nitrogen compounds and phosphates). Microbiological examination of biomass from the bioreactor indicated high diversity and activity of identified species, proving good conditions for both activated sludge and biofilm.
Źródło:
Journal of Ecological Engineering; 2016, 17, 5; 57-63
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bilans ChZT w biologicznym oczyszczaniu ścieków osadem czynnym - cz. I. skala laboratoryjna
Cod balance in biological treatment of wastewater - part I - laboratory scale
Autorzy:
Myszograj, S.
Powiązania:
https://bibliotekanauki.pl/articles/372054.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
bilans CzZT
węgiel organiczny
osad czynny
usuwanie azotu
balance of COD
organic carbon
activated sewage sludge
nitrogen removal
Opis:
W artykule przedstawiono metodę bilansowania ChZT w układach oczyszczania ścieków osadem czynnym. Sporządzono bilans ChZT dla laboratoryjnych układów technologicznych. Potwierdzono, że zbilansowanie ChZT możliwe jest wyłącznie dla reaktorów tlenowych lub układów anoksyczno/tlenowych.
In this article, the bases of COD balancing in aerobic, anoxic and anaerobic activated sludge systems were introduced. Literature data has been showing, that simulations of balances COD close 100% are possible for aerobic reactors or anoxic/aerobic systems. On systems including anaerobic zones the balance of COD is close maximally in 85%. It is suggested, that the "loss" COD, which becomes appointed in balances, is associated with the process of hydrolysis or the fermentation of organic matter. Inappropriate accepting the "loss" COD in modelling and optimization of activated sludge process, influences on the growth of aeration costs and quantity of sewage sludge.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2010, 140 (20); 102-111
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature impact of nitrogen transformation in technological system: vertical flow constructed wetland and polishing pond
Wpływ temperatury na przemiany azotu w układzie technologicznym: złoże hydrofitowe o przepływie pionowym i staw doczyszczający
Autorzy:
Myszograj, S.
Bydałek, F.
Powiązania:
https://bibliotekanauki.pl/articles/396063.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
constructed wetlands
temperature
nitrogen removal
first-order kinetics
oczyszczalnie hydrofitowe
temperatura
usuwanie azotu
kinetyka pierwszego rzędu
Opis:
The article describes the results of the research, purpose of which was to evaluate influence of the temperature on the effectiveness of nitrification and denitrification in the sewage treatment system consisting of vertical flow constructed wetland and polishing pond. During the analysed period, the efficiency of removing total nitrogen was low and amounted to 12.7%. In the polishing pond in the summer period, content of total nitrogen in treated sewages was further decreased by nearly 50%. In the winter period, the polishing pond fulfilled mainly retention role and thus did not improve effectiveness of the whole system. Temperature coefficients, calculated on the basis of single first-order kinetics, for nitrification process in the filter bed (N-NH4+) and denitrification process in the polishing pond (N-NO3-) amounted to 1.039 and 1.089, respectively.
W artykule opisano wyniki badań, których celem była ocena wpływu temperatury na efektywność procesów nitryfikacji i denitryfikacji w przydomowej oczyszczalni ścieków pracującej w układzie: złoże hydrofitowe o przepływie pionowym i staw doczyszczający. W analizowanym okresie sprawność usuwania azotu ogólnego była niska i osiągała wartość 12,7%. W stawie doczyszczającym w okresie letnim zawartość azotu ogólnego w ściekach oczyszczonych uległa dalszemu obniżeniu o blisko 50%. W okresie zimowym, staw pełnił głównie rolę retencyjną, nie przyczyniając się do zwiększania efektywności pracy całego układu. Wyznaczony współczynnik temperaturowy na podstawie założeń kinetyki pierwszego rzędu dla procesu nitryfikacji w złożu (N-NH4+) oraz denitryfikacji w stawie doczyszczającym (N-NO3-) wynosił odpowiednio 1.039 i 1.089.
Źródło:
Civil and Environmental Engineering Reports; 2016, No. 23(4); 125-136
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies