Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "relative permittivity" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Determination of Moisture Content in Synthetic Moulding Sand on the Grounds of Relative Permittivity Measurement
Autorzy:
Nowak, D.
Gal, B.
Granat, K.
Jaworski, G.
Więcławek, R.
Powiązania:
https://bibliotekanauki.pl/articles/352740.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
moisture content
moulding sands
relative permittivity
microwaves
Opis:
The presented research was aimed at searching for an exact and effective method of determining moisture content in traditional moulding sands. By measuring resonance frequency and quality factor of a waveguide resonance cavity, relative permittivity was determined for different synthetic moulding sands. Analysis of the presented results confirms a linear relation between relative permittivity values and moisture content values in the selected traditional moulding sands. The obtained linear relationship can be used as a reference characteristic for evaluation of humidity of moulding sand.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 4; 2189-2192
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the Material Relative Permittivity in the UHF Band by Using T and Modified Ring Resonators
Autorzy:
Jankowski-Mihułowicz, P.
Lichoń, W.
Pitera, G.
Węglarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/226863.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
relative permittivity
UHF band
ring resonator
T-resonator
Opis:
The complete methodology of designing T- and modified ring resonators in the UHF band are presented in the paper. On the basis of proposed algorithms, the dedicated software tool has been elaborated in order to determine material parameters of contemporary substrates. The program is implemented in the Mathcad environment and it includes the base of information on known materials used in electronic products. Also, test sample series for selected substrate materials (IS680, FR408, I-SPEED PCB ISOLA and A6-S LTCC FERRO) and operating requencies from 1 GHz to 3 GHz are analyzed in details. The special test stand with a vector network analyzer has been applied in experiments. The obtained data of relative permittivity measurements and model calculations are described, discussed and concluded.
Źródło:
International Journal of Electronics and Telecommunications; 2016, 62, 2; 129-134
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dielectric properties of papaya seeds from 75 kHz to 5 MHz
Autorzy:
Berbert, P.A.
Soares, K.J.
Moura, E.E.
Berbert-Molina, M.A.
Oliveira, M.T.R.
Martinazzo, A.P.
Powiązania:
https://bibliotekanauki.pl/articles/2082500.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
Carica papaya L.
dielectric loss factor
moisture content
relative permittivity
seed bulk density
Opis:
The object of this work was to study the dielectric properties of papaya seeds of the Golden cultivar and seeds of two papaya hybrids, Tainung and Calimosa, in the frequency range from 75 kHz to 5 MHz at four levels of bulk density, and with moisture contents ranging from 6 to 23% wet basis. The relative permittivity and the loss factor of the seeds were measured using a precision LCR meter, and their relationship with the variable frequency of the oscillating electric field, the seed moisture content and bulk density, and the cultivar/hybrid type were established. Relative permittivity for each value of the moisture content was reduced regularly as the frequency increased. Abrupt changes in the slopes of the curves demonstrating the relationship between the relative permittivity and the loss factor, and the moisture content were considered an indication of changes in the water sorption mechanisms occurring within the seed. The relationship between the relative permittivity and the loss factor, and bulk density was represented by linear functions with positive slopes. The effect of the cultivar or hybrid types on the relative permittivity and the loss factor revealed that seeds of the Golden cultivar and the Tainung hybrid exhibited similar relative permittivity values in the whole frequency range studied, in contrast to seeds of the Calimosa hybrid.
Źródło:
International Agrophysics; 2019, 33, 2; 185-192
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Four-parameter electromagnetic method for determining the parameters of brewery effluents
Autorzy:
Sebko, V. V.
Pyrozhenko, Ye. V.
Zashchepkina, N. M.
Zdorenko, V. G.
Markina, O. M.
Powiązania:
https://bibliotekanauki.pl/articles/2201046.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
four-parameter electromagnetic method
brewery effluents
magnetic flux probe
MFP
conversion function
joint measurement
electrical conductivity
relative permittivity
density
temperature
metoda elektromagnetyczna
ścieki
strumień magnetyczny
funkcja konwersji
przewodność elektryczna
względna przenikalność elektryczna
gęstość
temperatura
Opis:
Purpose of the article is to study a four-parameter electromagnetic method for joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of samples of acidic, alkaline and average effluents from a microbrewery based on a magnetic flux probe (MFP), which considers the influence of informative parameters of beer effluents on the components of the amplitude and phase signals of a multiparameter device. Design/methodology/approach The implementation of the four-parameter method is carried out on the basis of the dependences G1 = f (A1) and G2 = f (A2) at two frequencies of the electromagnetic field f0 and f1 for acid, alkaline and average effluent and allows you to jointly determine the four parameters of effluent samples with the same converter in the same control area. The proposed method makes it possible to improve the accuracy of identifying effluent samples since the obtained multiparameter information makes it possible to determine the nature and properties of effluent samples using only one transducer with certain physical characteristics. The research results lead to the expansion of the technical capabilities of electromagnetic measurement methods, as well as to an increase in the metrological characteristics of electromagnetic transducers and an increase in the accuracy of measuring the parameters of effluent samples compared to reference methods and measuring instruments. Thus, the implementation of this approach contributes to the prediction and prevention of the reasons for the deviation of beer effluent samples from the specified indicators of environmental safety. Findings The universal conversion functions MFP have been established, connecting the amplitude and phase components of the converter signals with the parameters k, εr, t and ρ of acidic, alkaline and average effluents. Based on the universal transformation functions G1 = f (A1) and G2 = f (A2), a four-parameter electromagnetic method for joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline, and average effluents from breweries has been developed. When conducting research at two close frequencies of the electromagnetic field f0 = 20.3 MHz and f1 = 22 MHz, algorithms were obtained for measuring and calculating procedures for determining k, εr, t and ρ for samples of acidic, alkaline and average effluents from the brewing industry. Research limitations/implications Research perspectives consist in the creation of automated systems for multiparameter measuring control of the physicochemical characteristics of acidic and alkaline effluent from food and processing industries based on the immersed electromagnetic transducer. Based on the data obtained using informative methods to measure the parameters of effluent samples, an integrated method for treating beer effluents of various compositions will be proposed. At the same time, the scheme of the integrated treatment method should include a filter that provides the introduction of a magnetic fluid and a separation device that allows us to remove a fraction, including pollution in itself. Practical implications Is that the proposed four-parameter electromagnetic method makes it possible to determine to what composition the controlled samples of wastewater should be attributed (acidic or alkaline). It, in turn, makes it possible to choose a rational method for treating beer effluents and to prevent the reasons for the deviation of effluent samples from the environmental safety indicators set by the standards. Originality/value of the article is the research related to the expansion of the functional and technical capabilities of the electromagnetic two-frequency transducer MFP through the implementation of a four-parameter electromagnetic method of joint measurements of electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline and average effluents from breweries. The universal transformation functions G1 = f (A1) and G2 = f (A2) found in the work at two close magnetic field frequencies, f0 = 20.3 MHz and f1 = 22 MHz, make it possible to control four physicochemical parameters of acidic, alkaline and average wastewater at the same time by the same MFP. An algorithm has been developed for determining the signal components of a two-frequency thermal MFP, the ranges of which correspond to the ranges of changes in electrical resistivity k, relative permittivity εr, temperature t and density ρ of acidic, alkaline, and average brewery effluents. The basic relations that describe the two-frequency four-parameter electromagnetic method of joint measurements of the physicochemical parameters of acidic, alkaline and averaged beer effluents have been obtained.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 113, 2; 49--64
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies