Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "refrigeration system" wg kryterium: Temat


Wyświetlanie 1-14 z 14
Tytuł:
Management decision making based on Markov reward models for refrigeration system
Autorzy:
Frenkel, I.
Khvatskin, L.
Lisnianski, A.
Powiązania:
https://bibliotekanauki.pl/articles/2069651.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Morski w Gdyni. Polskie Towarzystwo Bezpieczeństwa i Niezawodności
Tematy:
Markov reward models
reliability measures
average availability
MTTF
refrigeration system
Opis:
This paper presents a method for calculation the reliability measures of multi-state supermarket refrigeration system for decision making of system structure, where the system and its components can have different performance levels ranging from perfect functioning to complete failure. The suggested approach presents the Markov reward models for computation of average availability, total number of system’s elements failures and mean time to system failure for multi-state system. Corresponding procedures for reward matrix definition is suggested. A numerical example is presented in order to illustrate the approach.
Źródło:
Journal of Polish Safety and Reliability Association; 2010, 1, 1; 89--98
2084-5316
Pojawia się w:
Journal of Polish Safety and Reliability Association
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Exergy analysis of operation of two-phase ejector in compression refrigeration systems
Autorzy:
Dudar, A.
Butrymowicz, D.
Śmierciew, K.
Karwacki, J.
Powiązania:
https://bibliotekanauki.pl/articles/240804.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
two-phase ejector
compression refrigeration system
COP
exergy
strumienica dwufazowa
egzergia
Opis:
Paper deals with theoretical analysis of possible efficiency increase of compression refrigeration cycles by means of application of a two-phase ejector. Application of the two phase ejector in subcritical refrigeration system as a booster compressor is discussed in the paper. Results of exergy analysis of the system operating with various working fluids for various operating conditions have been shown. Analysis showed possible exergy efficiency increase of refrigeration compression cycle.
Źródło:
Archives of Thermodynamics; 2013, 34, 4; 107-122
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Maritime containers refrigeration plant faults survey
Autorzy:
Złoczowska, E.
Powiązania:
https://bibliotekanauki.pl/articles/27315835.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
refrigerated containers
refrigeration system faults
kontenery chłodnicze
układ chłodniczy
awarie układu chłodniczego
Opis:
Container transport is the most popular type of sea shipping around the world. The share of reefers (refrigerated container) in the total number of containers transported is about 15%.The worldwide stock of refrigerated containers used for transportation of perishable goods is still growing, while the conventional reefer fleet is shrinking. Still, despite of clean advantages they also carry some risks. Difficult operating conditions of refrigerated containers instigate very high risk of malfunctions, including permanent damage. The majority of articles about refrigerated systems failures, focus mainly on the onshore ones. Publications describing damage of reefers are limited. Therefore, this article attempts to classify and analyze the most frequent failures of container`s refrigeration units. This issue is very important for the crew safety, natural environment and high quality product preservation. The data necessary to perform the analysis come from reports on units damaged over two years. Introduction presents the characteristic of refrigerated containers and problems which occur during their exploitation. Next, the research methodology is presented. Eventually, the research results are presented and discussed. The summary and conclusions close the work.
Źródło:
New Trends in Production Engineering; 2018, 1, 1; 589-595
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zastosowania magazynu ciepła z materiałem PCM przy niedopasowaniu wydajności źródła i odbiornika chłodu
Autorzy:
Karwacki, Jarosław
Kwidziński, Roman
Lackowski, Marcin
Kapica, Paulina
Śniadała, Tadeusz
Leputa, Piotr
Laskowski, Marek
Powiązania:
https://bibliotekanauki.pl/articles/89589.pdf
Data publikacji:
2019
Wydawca:
Nowa Energia
Tematy:
ciepłownictwo
kogeneracja
magazyn ciepła
PCM
układ chłodniczy
heating
cogeneration
heat storage
refrigeration system
Opis:
W pracy omówiono zagadnienia projektowe związane z doborem magazynu chłodu z materiałem PCM do instalacji wody lodowatej zasilanej agregatem adsorpcyjnym. Dla analizowanego obiegu opracowano model o parametrach skupionych i wykonano obliczenia pięciu różnych przypadków. Analiza otrzymanych wyników pozwoliła na określenie optymalnej wielkości magazynu oraz wpływu działania elementów automatyki.
Źródło:
Nowa Energia; 2019, 2; 40-49
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of mechanical vapour compression refrigeration system part 2: performance challenge
Autorzy:
Mahmood, R. A.
Ali, O. M.
Al-Janabi, A.
Al-Doori, G.
Noor, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/2106451.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
para
układ chłodniczy
współczynnik wydajności
vapour compression
refrigeration system
cycle
coefficient of performance COP
Opis:
Reducing energy consumption and providing high performance for a vapour compression refrigeration system are big challenges that need more attention and investigation. This paper provides an extensive review of experimental and theoretical studies to present the vapour compression refrigeration system and its modifications that can be used to improve system’s performance and reduce its energy consumption. This paper also presents the challenges that can be considered as a gab of research for the future works and investigations. Cooling capacity, refrigerant effect, energy consumption can be improved by using vapour injection technique, natural working fluid, and heat exchanger. Based on the outcome of this paper, vapour injection technique using natural refrigerant such as water can provide ultimate friendly refrigeration system. Future vision for the vapour compression refrigeration system and its new design technique using Computational Fluid Dynamic (CFD) is also considered and presented.
Źródło:
International Journal of Applied Mechanics and Engineering; 2021, 26, 3; 119--130
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The methodology of multiple criteria decision making for selecting the refrigeration system of gastronomic furniture
Metodyka wielokryterialnego wspomagania podejmowania decyzji w zastosowaniu do wyboru układu chłodniczego mebli gastronomicznych
Autorzy:
Bernat, Tomasz
Bieńczak, Krzysztof
Górny, Kasper
Powiązania:
https://bibliotekanauki.pl/articles/337655.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
multiple criteria decision making
refrigeration system
gastronomic furniture
wielokryterialne wspomaganie decyzji
układ chłodniczy
meble gastronomiczne
Opis:
The growing request for refrigeration gastronomic furniture make necessary to functional and correct select the refrigeration unit. Unfortunately, it is not impossible just indicate one best solution. The best solution can be chosen for a specific user, taking into account the specific requirements of the product. The multiple criteria choice procedure presented the article may be used to implement such undertaking. In addition, the available methods used for multiple criteria decision making are presented, and one of them is selected for the selected decision problem. Based on real values and criteria, the methodology was presented and a multiple criteria analysis was carried out to support the final selection.
Rosnące zapotrzebowanie na chłodnicze mebla gastronomiczne, powoduje konieczność sprawnego i prawidłowego wyboru zastosowanego urządzenia chłodniczego. Niestety nie można wskazać tylko jednego najlepszego rozwiązania. Rozwiązanie najkorzystniejsze można dobrać dla konkretnego użytkownika uwzględniając szczegółowe wymagania dotyczące wyrobu. Do realizacji tego przedsięwzięcia może być wykorzystana procedura wielokryterialnego wyboru przedstawiona w niniejszym artykule. Ponadto przedstawiono dostępne metody wykorzystywane do oceny wielokryterialnej, oraz dokonano wyboru jednej z nich dla wybranego problemu decyzyjnego. Opierając się o rzeczywiste wartości oraz kryteria, zaprezentowano metodykę oraz przeprowadzono analizę wielokryterialną wspomagającą dokonanie ostatecznego wyboru.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2019, 64, 2; 15-18
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspekty prawne i techniczne stosowania czynnika CO2 w instalacjach chłodniczych
Legal and technical aspects of the use of CO2 as refrigerant
Autorzy:
Szelągowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/270669.pdf
Data publikacji:
2017
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
czynniki chłodnicze
potencjał tworzenia efektu cieplarnianego
chłodnictwo
klimatyzacja
bezpieczeństwo instalacji chłodniczych
refrigerants
greenhouse effect
refrigeration
air conditioning
safety of refrigeration system
Opis:
Czynniki chłodnicze stosowane w instalacjach chłodniczych, klimatyzacyjnych oraz pompach ciepła ze względu na negatywny wpływ na środowisko naturalne od kilku dekad podlegają coraz ostrzejszym regulacjom prawnym. Zgodnie z traktatami międzynarodowymi dotyczącymi ochrony klimatu w pierwszej kolejności zakazano stosowania czynników z grupy HCFC, które bezpośrednio wpływały na degradację warstwy ozonowej. W ich miejsce na szeroką skalę zaczęto stosować czynniki z grupy HFC, które nie mają negatywnego wpływu na warstwę ozonową Ziemi, jednak należą do tzw. f-gazów, czyli substancji zawierających fluor i mających istotny wpływ na występowanie efektu cieplarnianego. Alternatywą dla tych substancji są czynniki naturalne na bazie węglowodorów (HC) oraz czynniki nieorganiczne, do których należą amonia, woda i dwutlenek węgla. Wpływ tych czynników na efekt cieplarniany jest niewielki, natomiast stosowanie tych substancji niesie ze sobą pewne trudności techniczne. Publikacja ma za zadanie przedstawić aspekty prawne i techniczne stosowania dwutlenku węgla w instalacjach chłodniczych.
The refrigerants used in refrigeration, air-conditioning and heat pumps have been subject to legal regulations for several decades. According to the international treaties on climate protection, the use of HCFCs, which directly affected the degradation of the ozone layer, was banned in the first phase. They were replace by HFCs which been used on a large scale. HFCs do not have a negative impact on the Earth’s ozone layer, but they belong to the so-called f-gases, substances that are fluorine compounds, and having a significant effect on the greenhouse effect. Alternatives to these substances are hydrocarbon-based natural agents (HC) and inorganic agents which include ammonia, water and carbon dioxide. Their impact on the greenhouse effect of these substances is small, but the use of these substances has some technical difficulties. The publication aims at presenting the legal and technical aspects of the use of carbon dioxide in refrigeration installations.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2017, 22, 4; 269--276
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical vapour compression refrigeration system: review part 1: environment challenge
Autorzy:
Mahmood, Raid Ahmed
Ali, Omar M.
Noor, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/1839710.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
czynnik chłodniczy
układ chłodniczy
warstwa ozonowa
alternative refrigerant
mixture refrigerants
vapour compression refrigeration system
ozone depletion potential
global worming potential
R507A refrigerant
natural refrigerant
R-718 (water/steam)
Opis:
In Australia and others developed countries, concerns about global warming have increased, and these concerns influence the use of refrigerants as working fluids in mechanical vapour compression refrigeration systems. One of the most important aspects of refrigerant selection is to reduce its impact on the environment and the ozone layer. This paper provides a comprehensive review of various theoretical and experimental studies which have been carried out on air conditioning and refrigeration applications to investigate the effect of refrigerants on the environment. The analysis in this paper reveals that alternative refrigerants are the most suitable working fluids that can be used in refrigeration systems to meet the needs of the environment. This study also suggests that natural types of refrigerants such as water, carbon dioxide, and hydrocarbon will play a significant role in protecting the environment and providing alternative friendly refrigerants to be used in refrigeration and air conditioning systems.
Źródło:
International Journal of Applied Mechanics and Engineering; 2020, 25, 4; 130-147
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Year-round operation the solar powered hybrid adsorption-compression refrigeration cycle
Autorzy:
Cyklis, Piotr
Duda, Robert
Powiązania:
https://bibliotekanauki.pl/articles/95366.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
hybrid compression adsorption refrigeration cycle
refrigeration cycle
hybrydowy adsorpcyjno-sprężarkowy system chłodniczy
system chłodniczy
Opis:
In our earlier papers a hybrid adsorption-compression refrigeration cycle was presented. The hybrid, two stages cycle is based only on the natural refrigerants: water and carbon dioxide. The main advantage of the hybrid cycle is that the carbon dioxide compression cycle is subcritical because during the year-round operation it is possible to maintain the condensing temperature below 20°C. During the hot season, this is achieved by adsorption cooling, during cold seasons the wet cooling tower is sufficient. Already several years of experience, allowed to gather a considerable amount of measurement data. The refrigeration system is working in our laboratory constantly since 2013. In 2015 the adsorption system was upgraded by the manufacturer. In 2017 frequency inverter for wet tower fan controlling was introduced. The refrigeration chamber was used for tests with different content and operation of the refrigeration chamber (loading and unloading). The assumed CO2 evaporating temperature was -35°C. The averaged for HT (High Temperature) part of the cascade (adsorption cycle only) COPHT=0.51 for the whole year 2018. This may be considered a very good performance. Averaged total COP for the cascade system: COP=0.9 compared to COP=0.84 for compression only refrigeration cascade, with much higher TEWI index. For comparison for two-stage compression (R407CHT+R744LT) cycle was used. This means that if the cooling tower fan operation is controlled using an inverter, adjusted to the actual heat removal demand, the hybrid cycle is not only ecological but also energetically efficient.
Źródło:
Journal of Mechanical and Energy Engineering; 2019, 3, 4; 317-322
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The energy efficiency monitoring of a refrigeration unit
Autorzy:
Jaszczak, S.
Łokietek, T.
Powiązania:
https://bibliotekanauki.pl/articles/114062.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
refrigeration unit
SCADA system
energy efficiency
Opis:
In the paper, a monitoring system of a refrigeration unit is presented. This system consists of several measurement elements e.g. (pressure, temperature, energy, etc. sensors) connected using a serial RS485 network. A measurement level is a source of data for both SCADA environment and a PLC controller which are essential elements of the whole control system. The first stage of the study was related to the selection of measurement devices and a construction of a serial network. The authors also described how to link a serial 485 network with a PLC controller and how to introduce it into TCP/IP network. In the first part of the paper, there is presented a refrigeration unit as a subject of the monitoring. Then the authors describe a theoretical background needed for the energy efficiency calculation. After that the system structure with selected details about hardware integration and SCADA software implementation is presented. The final part contains selected real time experiments to show typical working modes of the refrigeration unit and to prove the efficiency of the developed monitoring system.
Źródło:
Measurement Automation Monitoring; 2016, 62, 6; 202-205
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of selected cooling systems on the urban natural environment
Autorzy:
Matuszak, Zbigniew
Złoczowska, Ewelina
Żabińska, Iwona
Powiązania:
https://bibliotekanauki.pl/articles/27313467.pdf
Data publikacji:
2022
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
cooling system
refrigeration
urban environment
system chłodzenia
chłodzenie
środowisko miejskie
Opis:
Purpose: The aim of the paper is to indicate the possibility of using refrigerants which do not have a harmful effect on the destruction of the Earth's ozone layer and the urban environment. Design/methodology/approach: The environmental impact of refrigerants was characterized. Selected refrigerants and their place of application are described. The impact of selected refrigerants on the urban environment is presented. Findings: An attempt has been made to identify the absolute environmental impact of selected stationary refrigeration systems in operation in cities, i.e. home refrigerators, individual air conditioners, heat pumps, air conditioning systems of large-format stores - shopping centers, or cold stores. Both the direct impact related to the refrigerant used in the system and the indirect one related to the energy consumption to drive the device have been considered. Practical implications: Use of new refrigerants that do not damage the Earth's ozone layer. Originality/value: The environmental impact of different refrigerants is presented. The paper is addressed to technical services and personnel responsible for the design and operation of refrigeration and air-conditioning equipment.
Źródło:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska; 2022, 161; 111--120
1641-3466
Pojawia się w:
Zeszyty Naukowe. Organizacja i Zarządzanie / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research to estimate energy efficiency of a ventilation and air conditioning heat pump system inside a production premise with ventilation air recovery
Autorzy:
Bezrodny, Myhailo Kostiantynovych
Misiura, Tymofii Oleksiyovych
Powiązania:
https://bibliotekanauki.pl/articles/1955060.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
air conditioning
heat pump system
refrigeration efficiency
recuperation
Opis:
The research provides a thermodynamic analysis of the theoretical model of a ventilation and air conditioning heat pump system with the ventilation air cold energy recovery depending on outside air parameters, the recovery efficiency and characteristics of a premise. A confectionery production workshop was taken as a prototype where technological conditions (temperature and humidity) must be maintained during the warm season. Calculations using the method of successive approximations to estimate air parameters at system’s nodal points were conducted. It allowed to determine theoretical refrigeration efficiency of the studied system and proved advantages of heat recuperation for smaller energy consumption. The model can be applied for design of heating, ventilation, and air conditioning units which work as a heat pump. The studied system has the highest energy efficiency in the area of relatively low environment temperatures and relative humidity which is suitable for countries with temperate continental climates characterized by low relative humidity.
Źródło:
Archives of Thermodynamics; 2021, 42, 4; 69-86
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Study On Thermal Wave Type Adsorption Refrigeration System Working On A Pair Of Activated Carbon And Methanol
Autorzy:
Grzebielec, A.
Rusowicz, A.
Laskowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/185575.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
refrigeration
adsorption system
experimental study
AC-methanol pair
chłodzenie
system adsorpcji
badania eksperymentalne
Opis:
The aim of the study was to examine the efficiency of the thermal wave type adsorption refrigerating equipment working on a pair of activated carbon and methanol. Adsorption units can work in trigeneration systems and in applications driven by waste heat. They can be built also as a part of hybrid sorption-compressor systems, and they are very popular in solar refrigeration systems and energy storage units. The device examined in this study operates in a special mode called thermal wave. This mode allows to achieve higher efficiency rates than the normal mode of operation, as a significant contributor to transport heat from one to the other adsorber. To carry out the experiment a test bench was built, consisting of two cylindrical adsorbers filled with activated carbon, condenser, evaporator, oil heater and two oil coolers. Thermal oil circulation was responsible for providing and receiving heat from adsorbers. In order to perform the correct action a special control algorithm device was developed and implemented to keep the temperature in the evaporator at a preset level. The experimental results show the operating parameters changes in both adsorbers. Obtained COP (coefficient of performance) for the cycle was 0.13.
Źródło:
Chemical and Process Engineering; 2015, 36, 4; 395--404
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of CCHP in deep mine thermal hazard control
Zastosowanie systemu trójgeneracji w systemie kontroli zagrożeń termicznych w kopalni głębinowej
Autorzy:
Yang, D. D.
Wang, B. S.
Zhou, S. G.
Qin, R. X.
Powiązania:
https://bibliotekanauki.pl/articles/348684.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
system trójgeneracji
kopalnia o wysokiej metanowości
kontrola zagrożeń cieplnych
chłodzenie absorpcyjne
CCHP
high gas mine
thermal hazard control
absorption refrigeration
Opis:
Due to the characteristics of high gas, high geothermal temperature and high strength development in Huainan mine area, thermal hazard problem has become more and more serious and also affects safety and productivity in coal mine. The CCHP (combined cooling heating and power), as a new mode to control thermal hazard, is put forward after advantages and disadvantages of all kinds of cooling methods are investigated. The CCHP method not only takes full advantage of gas but also reduces the greenhouse gas emission. At the same time, the application of CCHP remits the pressure of the power supply in summer, providing guarantee for safe and high efficiency exploitation.
W związku z wysoką gazonośnością, wysoką temperaturą pierwotną górotworu i wysokimi wartościami zawartości metanu w kopalni Huainan zaobserwowano zagrożenia natury cieplnej, wpływające również na bezpieczeństwo i wydajność produkcji w kopalni. Po zbadaniu wad i zalet różnych metod klimatyzacji podjęto decyzję o wprowadzeniu systemu trójgeneracji jako nowego sposobu kontroli zagrożeń natury cieplnej. Metoda trójgeneracji nie tylko wykorzystuje pełen potencjał ujętego gazu, ale również pozwala obniżyć emisję gazów cieplarnianych. Zastosowanie tego systemu zmniejsza ponadto pobór energii zasilającej w porze letniej, dając gwarancję bezpiecznej i wydajnej eksploatacji kopalni.
Źródło:
AGH Journal of Mining and Geoengineering; 2012, 36, 3; 443-451
1732-6702
Pojawia się w:
AGH Journal of Mining and Geoengineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies