Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "refrigerants" wg kryterium: Temat


Tytuł:
Modeling the phenomena accompanying the condensation of environmentally friendly refrigerants in mini-channels
Autorzy:
Kuczyński, Waldemar
Powiązania:
https://bibliotekanauki.pl/articles/2204074.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
refrigerants
condensation
mini-channels
Opis:
This paper presents the results of an experimental study and mathematical modeling of the effect of dynamic instabilities on the condensation phase transformation of the refrigerants homogeneous R134a and its replacement in the form of isomers R1234yf and R1234ze and R404A or R507 and R448A in pipe mini-channels. In the case of homogeneous chlorofluorocarbons (CFCs), it is the 1234 isomers that are envisioned as substitutes for the withdrawn ones with high ozone depletion potential and global warming potential. For zeotropic and azeotropic mixtures, for example, these are R507 or R448A. The paper presents a dimensional analysis procedure based on the Buckingham Π theorem to develop a regression velocity model of pressure dynamic instabilities. The experimental part of the work was carried out with the use of tubular mini-channels with internal diameter 1.40–3.3 mm.
Źródło:
Archives of Thermodynamics; 2023, 44, 1; 121--137
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New refrigerants used by heat pumps
Autorzy:
Grzebielec, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1818462.pdf
Data publikacji:
2020
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
heat pump
refrigerants
GWP
pompa ciepła
czynniki chłodnicze
Opis:
The date is inevitably approaching when refrigerants such as R407C (GWP 1774) and R410A (GWP 2088) cannot be used in newly introduced refrigeration, air conditioning and heat pump equipment. From January 1, 2020, there is a ban on placing on the market devices with refrigerants with a GWP greater than 2500, and from January 1, 2025 the limit value will be 750. Thus, devices filled with R404A (GWP 3922) have already disappeared from the primary market. Despite the anticipated changes in the short term, heat pumps with refrigerants such as R407C or R410A still dominate the sale. Devices with R134a (GWP 1430), R32 (GWP 675), R290 propane (GWP 3) or R744 carbon dioxide are sold to a lesser extent.
Źródło:
Modern Engineering; 2020, 3; 100--106
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New refrigerants used by heat pumps
Autorzy:
Grzebielec, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1818464.pdf
Data publikacji:
2020
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
heat pump
refrigerants
GWP
pompa ciepła
czynniki chłodnicze
Opis:
The date is inevitably approaching when refrigerants such as R407C (GWP 1774) and R410A (GWP 2088) cannot be used in newly introduced refrigeration, air conditioning and heat pump equipment. From January 1, 2020, there is a ban on placing on the market devices with refrigerants with a GWP greater than 2500, and from January 1, 2025 the limit value will be 750. Thus, devices filled with R404A (GWP 3922) have already disappeared from the primary market. Despite the anticipated changes in the short term, heat pumps with refrigerants such as R407C or R410A still dominate the sale. Devices with R134a (GWP 1430), R32 (GWP 675), R290 propane (GWP 3) or R744 carbon dioxide are sold to a lesser extent.
Źródło:
Modern Engineering; 2020, 3; 100--106
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New refrigerants used by heat pumps
Autorzy:
Grzebielec, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1818457.pdf
Data publikacji:
2020
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
heat pump
refrigerants
GWP
pompa ciepła
czynniki chłodnicze
Opis:
The date is inevitably approaching when refrigerants such as R407C (GWP 1774) and R410A (GWP 2088) cannot be used in newly introduced refrigeration, air conditioning and heat pump equipment. From January 1, 2020, there is a ban on placing on the market devices with refrigerants with a GWP greater than 2500, and from January 1, 2025 the limit value will be 750. Thus, devices filled with R404A (GWP 3922) have already disappeared from the primary market. Despite the anticipated changes in the short term, heat pumps with refrigerants such as R407C or R410A still dominate the sale. Devices with R134a (GWP 1430), R32 (GWP 675), R290 propane (GWP 3) or R744 carbon dioxide are sold to a lesser extent.
Źródło:
Modern Engineering; 2020, 3; 100--106
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
New environmentally friendly low-pressure refrigerants mini-channel
Autorzy:
Sikora, Malgorzata
Bohdal, Tadeusz
Powiązania:
https://bibliotekanauki.pl/articles/2204072.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
refrigerants
global warming potential
ozone depletion potential
fluorinert liquid
hydrofluoroether
Opis:
Nowadays, in addition to the thermodynamic properties of refrigerants, their impact on the environment is of high significance. Hence, it is important to use refrigerants with the lowest possible values of ozone depletion potential and global warming potential indices in refrigeration, organic Rankine cycle (ORC), air conditioning, and heat pump systems. Natural refrigerants are the most environmentally friendly; unfortunately, they have less favourable thermodynamic properties. Currently, low-pressure refrigerants from the FC (fluorocarbons, fluorine liquids) and HFE (hydrofluoroether) groups are increasingly used. This paper presents the most important properties and applications of selected refrigerants from these groups and also reviews the literature on their use.
Źródło:
Archives of Thermodynamics; 2023, 44, 1; 89--104
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność energetyczna systemu klimatyzacji samochodowej współpracującej z różnymi czynnikami chłodniczymi
The energy efficiency of automotive air conditioning system working with different refrigerants
Autorzy:
Tuchowski, W.
Nikończuk, P.
Powiązania:
https://bibliotekanauki.pl/articles/310524.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
klimatyzacja samochodowa
czynniki chłodnicze
efektywność energetyczna
car air conditioning
refrigerants
energy efficiency
Opis:
W artykule poddano analizie systemy klimatyzacji samochodowej pod względem efektywności energetycznej. Obecnie w układach tych najpopularniejsze czynniki chłodnicze to R 134a - czynnik chłodniczy który posiada dość znaczny potencjał tworzenia efektu cieplarnianego (GWP = 1440) oraz R 1234 yf - posiada niską wartość GWP = 4, lecz istnieją pewne kontrowersje związane z wpływem produktów jego spalania na zdrowie i życie człowieka. Na te szkodliwe produkty spalania (kwas fluorowodorowy) narażeni jesteśmy zwłaszcza podczas kolizji drogowej kiedy to w jej następstwie rozszczelnieniu ulegnie układ klimatyzacji. W związku z wątpliwościami dotyczącymi tego czynnika m.in. Mercedes wprowadził na rynek auta z układami klimatyzacji współpracującymi z czynnikiem chłodniczym R 744 - dwutlenkiem węgla. Trwają również badania nad zastosowaniem czynników R 290 (propan) oraz R 600a (izobutan), ciekawą alternatywą jest również R 152a oraz R 717 (amoniak).
The article analyzes automotive air conditioning systems in terms of energy efficiency. Currently, for these systems the most popular are two refrigerants R-134a and R 1234 yf. The R 134a is the refrigerant that has a fairly high global warming potential (GWP = 1,440). R1234yf - has a low GWP = 4, but there are controversies related to the impact its products of combustion to human health and life. Due to concerns regarding this refrigerant, among others the Mercedes Company launched the car with the air conditioning systems working with the refrigerant R 744 - carbon dioxide. Also are ongoing research on the use of refrigerants R 290 (propane) and R600a (isobutane), an interesting alternative is the R 152a and R-717 (ammonia).
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 746-748
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of flow boiling heat transfer data for R134a, R600a and R290 in minichannels
Autorzy:
Mikielewicz, D.
Jakubowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/240780.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
flow boiling
natural refrigerants
minichannels
wrzenie w przepływie
naturalne czynniki chłodnicze
minikanały
Opis:
In the paper presented is the analysis of the results of calculations using a model to predict flow boiling of refrigerants such as R134a, R600a and R290. The latter two fluids were not used in the development of the model semiempirical correction. For that reason the model was verified with present experimental data. The experimental research was conducted for a full range of quality variation and a relatively wide range of mass velocity. The aim of the present study was also to test the sensitivity of developed model to a selection of the model of two-phase flow multiplier and the nonadiabatic effects. For that purpose two models have been analysed namely the one due to Müller-Steinhagen and Heck, and Friedel. In addition, the work shows the importance of taking surface tension into account in the calculation of the flow structure.
Źródło:
Archives of Thermodynamics; 2014, 35, 4; 97-114
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Functional dependence of thermodynamic and thermokinetic parameters of refrigerants used in mine air refrigerators. Part 1 – Refrigerant R407C
Zależności funkcyjne parametrów termodynamicznych i termokinetycznych czynników chłodniczych stosowanych w górniczych chłodziarkach powietrza. Część 1 – Czynnik chłodniczy R407C
Autorzy:
Nowak, B.
Życzkowski, P.
Łuczak, R.
Powiązania:
https://bibliotekanauki.pl/articles/219737.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
czynniki chłodnicze
R407C
parametry termodynamiczne i termokinetyczne
refrigerants
thermodynamic and thermokinetic parameters
Opis:
The authors of this article dealt with the issue of modeling the thermodynamic and thermokinetic properties (parameters) of refrigerants. The knowledge of these parameters is essential to design refrigeration equipment, to perform their energy efficiency analysis, or to compare the efficiency of air refrigerators using different refrigerants. One of the refrigerants used in mine air compression refrigerators is R407C. For this refrigerant, 23 dependencies were developed, determining its thermodynamic and thermokinetic parameters in the states of saturated liquid, dry saturated vapour, superheated vapor, subcooled liquid, and in the two-phase region. The created formulas have been presented in Tables 2, 5, 8, 10 and 12, respectively. It should be noted that the scope of application of these formulas is wider than the range of changes of that refrigerant during the normal operation of mine refrigeration equipment. The article ends with the statistical verification of the developed dependencies. For this purpose, for each model correlation coefficients and coefficients of determination were calculated, as well as absolute and relative deviations between the given values from the program REFPROP 7 (Lemmon et al., 2002) and the calculated ones. The results of these calculations have been contained in Tables 14 and 15.
Autorzy niniejszego artykułu zajęli się zagadnieniem modelowania właściwości (parametrów) termodynamicznych i termokinetycznych czynników chłodniczych. Znajomość tych parametrów jest niezbędna do projektowania urządzeń chłodniczych, ich analizy energetycznej, a także do porównaniu efektywności pracy chłodziarek powietrza wykorzystujących różne czynniki chłodnicze. Jednym ze stosowanych w górniczych sprężarkowych chłodziarkach powietrza czynnikiem chłodniczym jest R407C. Dla wymienionego czynnika chłodniczego opracowano 23 zależności określające jego parametry termodynamiczne i termokinetyczne w stanie cieczy nasyconej, w stanie pary nasyconej suchej, w stanie pary przegrzanej, w stanie cieczy przechłodzonej oraz w stanie pary mokrej. Utworzone wzory podano odpowiednio w tabelach: 2, 5, 8, 10 i 12. Należy zaznaczyć, że zakresy obowiązywania tych wzorów są szersze od zakresów zmian tego czynnika podczas normalnej pracy górniczych urządzeń chłodniczych. Artykuł kończy weryfikacja statystyczna utworzonych zależności. W tym celu dla każdego wzoru obliczono współczynniki korelacji, determinacji oraz odchyłki bezwzględne i względne między wartościami danymi z programu REFPROP 7 (Lemmon i in., 2002) a obliczonymi. Rezultaty tych obliczeń zamieszczono w tabelach 14 i 15.
Źródło:
Archives of Mining Sciences; 2017, 62, 1; 55-72
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiana parametrów termodynamicznych powietrza w parowniku chłodziarki górniczej z czynnikiem R407C
The change of thermodynamic variables of air in the mine refrigerator evaporator with the refrigerant R407C
Autorzy:
Filek, K.
Łuska, P.
Nowak, B.
Powiązania:
https://bibliotekanauki.pl/articles/349186.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
klimatyzacja kopalń
chłodzenie powietrza
czynnik chłodniczy
mine air conditioning
cooling of air
refrigerants
Opis:
W pracy zamieszczono wyniki pomiarów zmian temperatury i wilgotności powietrza zachodzących w parowniku chłodziarki górniczej z czynnikiem R407C. Badaniom poddano 45 wariantów różniących się temperaturą i wilgotnością względną powietrza przed schłodzeniem oraz natężeniem jego przepływu przez parownik. W pracy przedstawiono wyniki 24 wariantów, w których parametry wlotowe powietrza są najbardziej zbliżone do rzeczywistych, występujących w wyrobiskach kopalń podziemnych. Ponadto wykorzystując równania matematycznego modelu pracy chłodziarki, wykonano numeryczne obliczenia parametrów powietrza schłodzonego i mocy cieplnej parownika dla wariantów pomiarowych, tj. przyjmując rezultaty pomiarów parametrów powietrza przed schłodzeniem jako dane wejściowe do obliczeń. Wyniki pomiarów i obliczeń zestawiono w formie tabelarycznej oraz w postaci wykresów.
The main topic in this publication is connected with work of mine compression refrigerator with the refrigerant R407C. The publication includes the results of the change of temperature and air humidity, which are proceed in the evaporator. 45 variants were tested. This variants were differed in properties (temperature, relative humidity and flow rate through the evaporator). In the work are shown the results of 24 variants, for which the properties of air inlet are the most close to reality (excavations in the underground mines). Moreover, this publication includes the results of numerical calculations of precooled air parameters and the thermal power of evaporator. In this case all results of air parameters before precooling are used as the input data. The findings are compiled in the tabular form and in the shape of diagram.
Źródło:
Górnictwo i Geoinżynieria; 2006, 30, 1; 15-24
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane aspekty prawno-techniczne i ekologiczne stosowania sprężarkowych pomp ciepła
Selected Aspects of Legal, Technical and Ecological Use of Compression Heat Pumps
Autorzy:
Bohdal, T.
Charun, H.
Sikora, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818544.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
pompy ciepła
czynniki chłodnicze
R1234yf
R1234ze
COP
GWP
ODP
heat pumps
refrigerants
Opis:
Destructive impact of chlorofluorocarbons refrigerants (CFCs), especially R12 and R22, on the environment (creation of the ozone hole and the greenhouse effect) led to their withdrawal from use in refrigeration and heat pumps. Due to the high global warming potential (GWP=1300) also widely used R134a refrigerant will be withdrawn from use from 2017. Ongoing search for environmentally friendly alternatives refrigerants among which are listed the refrigerants from the R1234 group – especially R1234yf. In previous publications of various authors, was analyzed the use of this refrigerant in refrigeration. The authors have made an attempt on the possibility of the application of this refrigerant in the compressor, steam heat pumps. Made comparative calculations indicate that implementation of this substitute is possible in a limited scope resulting from the reduction of the heating capacity outputted to the upper source.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 461-484
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies