Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "reduction of area" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Study of dam sediment distribution using experimental area-reduction method Case study: Karun Dam
Autorzy:
Yusuf, Rakhmat
Komariah, Aan
Kurniady, Dedy Achmad
Mardiani, Mardiani
Jumintono, Jumintono
Falih, Khaldoon T.
Kabanov, Oleg V.
Aravindhan, Surendar
Kadhim, Mustafa Mohammed
Powiązania:
https://bibliotekanauki.pl/articles/2174333.pdf
Data publikacji:
2022
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
area-reduction method
dam reservoir
distribution of sediment
elevation-area curve
elevation-volume curve
Opis:
Dam construction is one of the measures that is inevitable in many cases and must be done to supply drinking water, agricultural uses and electricity generation. There are many challenges to a successful dam project, and the managers of each project must consider the appropriate solutions for them. One of the studies that is done in dam design is sedimentation in dam reservoirs. The experimental area-reduction method is a very common technique that obtains the sediment distribution in depth and longitudinal profile. This technique shows that sediment accumulation is not limited to the bottom reservoirs. Sediment accumulation in a reservoir is usually distributed below the top of the protection reservoir or normal water level. In this study, the distribution of sediment in the reservoir of Karun Dam after a period of 65 years has been done using the experimental area-reduction method. Elevation-volume and elevation-area curves of the dam reservoir are obtained after the useful life of the dam and sediment deposition. The results showed that after 65 years, 106.47·106 m3 of sediment is deposited in the reservoir of the dam and the useful volume of the reservoir is significantly reduced. Also, up to a height of 36.4 m, the dam reservoir is filled with sediment. Therefore, no valve should be placed up to this height.
Źródło:
Journal of Water and Land Development; 2022, 54; 116--120
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties of two manganese steels
Autorzy:
Cagala, M.
Mazancová, E.
Lichý, P.
Beňo, J.
Břuska, M.
Špirutová, N.
Powiązania:
https://bibliotekanauki.pl/articles/382392.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
krystalizacja
właściwości mechaniczne
stal wysokomanganowa
theory of crystallization
mechanical properties
high-manganese steel
reduction of area
precipitates
Opis:
The article is focused on thermomechanical and plastic properties of two high-manganese TRIPLEX type steels with an internal marking 1043 and 1045. Tensile tests at ambient temperature and at a temperature interval 600 C to 1100 C were performed for these heats with a different chemical composition. After the samples having been ruptured, ductility was observed which was expressed by reduction of material after the tensile test. Then the stacking fault energy was calculated and dilatation of both high-manganese steels was measured. At ambient temperature (20 C), 1043 heat featured higher tensile strength by 66MPa than 1045 heat. Microhardness was higher by 8HV0,2 for 1045 steel than for 1043 steel (203HV0,2). At 20 C, ductility only differed by 3% for the both heats. Decrease of tensile properties occurred at higher temperatures of 600 up to 1100 C. This tensile properties decrease at high temperatures is evident for most of metals. The strength level difference of the both heats in the temperature range 20 C up to 1100 C corresponded to 83 MPa, while between 600 C and 1100 C the difference was only 18 MPa. In the temperature range 600 C to 800 C, a decrease in ductility values down to 14 % (1045 heat), or 22 % (1043 heat), was noticed. This decrease was accompanied with occurrence of complex Aluminium oxides in a superposition with detected AlN particles. Further ductility decrease was only noted for 1043 heat where higher occurrence of shrinkage porosity was observed which might have contributed to a slight decrease in reduction of area values in the temperature range 900 C to 1100 C, in contrast to 1045 heat matrix.
Źródło:
Archives of Foundry Engineering; 2012, 12, 1; 9-12
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of water equivalents method to calculations of cross-finned aluminium heat exchangers
Zastosowanie metody równoważników wodnych do obliczeń poprzecznie użebrowanych aluminiowych wymienników ciepła
Autorzy:
Karczewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/263809.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wymiennik ciepła
równoważnik wodny
liczba jednostek przenikania ciepła
zredukowany współczynnik przenikania ciepła
powierzchnia wymiany ciepła
heat exchanger
water equivalent
number of heat transfer units
reduction over-all heat-transfer coefficient
heat surface area
Opis:
On an experimental post were carried out hydraulic and heat research of exchanger elements made of aluminium alloy. The research and calculations make possible to identify the reduction over-all heat-transfer coefficient from oil to heating air. The results of research enable to determine by water equivalents method design and using parameters of heat exchanger.
Na stanowisku doświadczalnym wykonano badania hydrauliczne i cieplne elementów wymiennika ciepła ze stopu aluminiowego. Badania i obliczenia umożliwiły identyfikację zredukowanego współczynnika przenikania ciepła od oleju do nagrzewanego powietrza. Wyniki badań umożliwiły określenie według metody równoważników wodnych parametrów konstrukcyjnych i eksploatacyjnych wymiennika ciepła.
Źródło:
Metallurgy and Foundry Engineering; 2010, 36, 1; 37-46
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies