Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "real-time implementation" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Novel solutions on model-based and model-free robotic-assisted ankle rehabilitation
Autorzy:
Arceo, Juan Carlos
Alvarez, Jorge
Armenta, Carlos
Lauber, Jimmy
Cremoux, Sylvian
Simoneau-Buessinger, Emilie
Bernal, Miguel
Powiązania:
https://bibliotekanauki.pl/articles/1409032.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
active disturbance rejection
computed torque control
differential algebraic equations
parallel rehabilitation robot
real-time implementation
system identification
Opis:
In this report, ankle rehabilitation routines currently approved by physicians are implemented via novel control algorithms on a recently appeared robotic device known as the motoBOTTE. The physician specifications for gait cycles are translated into robotic trajectories whose tracking is performed twofold depending on the availability of a model: (1) if obtained via the Euler-Lagrange approach along with identification of unknown plant parameters, a new computed-torque control law is proposed; it takes into account the parallel-robot characteristics; (2) if not available, a variation of the active disturbance rejection control technique whose parameters need to be tuned, is employed. A detailed discussion on the advantages and disadvantages of the model-based and model-free results, from the continuous-time simulation to the discrete-time implementation, is included.
Źródło:
Archives of Control Sciences; 2021, 31, 1; 5-27
1230-2384
Pojawia się w:
Archives of Control Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Implementation of IEC 61850 power protection tester in Linux environment
Autorzy:
Kurek, K.
Nogal, Ł.
Kowalik, R.
Januszewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/202357.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
implementation in real time
power systems
protective relay testing
digital control systems
IEC 61850
Opis:
Software power protection tester implemented in a real-time operating system (RTOS) might replace the conventional testing setups in IEC 61850 protection systems. This paper describes an open power protection testing platform. Linux RT capabilities related to runtime environment for such a tester are examined and OS latency sources are identified and evaluated. An algorithm for a multithreaded tester operation is proposed, including Sampled Values (SV) publisher, GOOSE input/output and time synchronization. SV and GOOSE services implemented in RT Linux environment are evaluated in accordance with IEC 61850‒5 transfer time requirements. Linux PTP time synchronization service of two similar systems controlling its electrical ports is evaluated in different synchronization scenarios. The developed tester is compared to an equivalent conventional setup during the test of IED over-current function. The conducted tests show that the Linux implementation of power protection tester in the case of scheduler latency, time synchronization accuracy and transfer time all meet the requirements of IEC 61850.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2020, 68, 4; 689-696
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
IEC 61850 interface for real time power system simulation
Autorzy:
Kurek, Karol
Nogal, Łukasz
Kowalik, Ryszard
Januszewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2128161.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
implementation in real time
power system
protection relays testing
computer simulation
IEC 61850
realizacja w czasie rzeczywistym
system zasilania
testowanie przekaźników zabezpieczeniowych
symulacja komputerowa
Opis:
Real time simulators of IEC 61850 compliant protection devices can be implemented without their analogue part, reducing costs and increasing versatility. Implementation of Sampled Values (SV) and GOOSE interfaces to Matlab/Simulink allows for interaction with protection relays in closed loop during power system simulation. Properly configured and synchronized Linux system with Real Time (RT) patch, can be used as a low latency run time environment for Matlab/Simulink generated model. The number of overruns during model execution using proposed SV and GOOSE interfaces with 50 µs step size is minimal. The paper discusses the implementation details and time synchronization methods of IEC 61850 real time simulator implemented in Matlab/Simulink that is built on top of run time environment shown in authors preliminary works and is the further development of them. Correct operation of the proposed solution is evaluated during the hardware-in-the-loop testing of ABB REL670 relay.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; e137057, 1--6
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
IEC 61850 interface for real time power system simulation
Autorzy:
Kurek, Karol
Nogal, Łukasz
Kowalik, Ryszard
Januszewski, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2173592.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
implementation in real time
power system
protection relays testing
computer simulation
IEC 61850
realizacja w czasie rzeczywistym
system zasilania
testowanie przekaźników zabezpieczeniowych
symulacja komputerowa
Opis:
Real time simulators of IEC 61850 compliant protection devices can be implemented without their analogue part, reducing costs and increasing versatility. Implementation of Sampled Values (SV) and GOOSE interfaces to Matlab/Simulink allows for interaction with protection relays in closed loop during power system simulation. Properly configured and synchronized Linux system with Real Time (RT) patch, can be used as a low latency run time environment for Matlab/Simulink generated model. The number of overruns during model execution using proposed SV and GOOSE interfaces with 50 µs step size is minimal. The paper discusses the implementation details and time synchronization methods of IEC 61850 real time simulator implemented in Matlab/Simulink that is built on top of run time environment shown in authors preliminary works and is the further development of them. Correct operation of the proposed solution is evaluated during the hardware-in-the-loop testing of ABB REL670 relay.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 3; art. no. e137057
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies