Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "reactors" wg kryterium: Temat


Tytuł:
Criticality calculations for the spent fuel storage pools for Etrr_1 and Etrr_2 reactors
Autorzy:
Aziz, M.
Andrzejewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/146151.pdf
Data publikacji:
2000
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
criticality safety
research reactors
Opis:
A criticality analysis of two spent fuel storage pools for Etrr_1 and Etrr_2 research reactors was performed. The multiplication factor for the pools was calculated as a function of relevant lattice physics parameters. Monte Carlo code MCNP-4A code was used in the criticality calculations. The results were compared with those given by CITATION code and the results obtained formerly during the design phase of the pools [9] with the MONK 6.3 code. Safety of the pools was confirmed.
Źródło:
Nukleonika; 2000, 45, 2; 141-144
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A multi-pulse diode rectifier with a coupled three-phase reactor - the design method and results of the simulation and laboratory tests
Autorzy:
Mysiak, P.
Jankowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/262693.pdf
Data publikacji:
2005
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power conditioning
multi-pulse power network converters
coupled three-phase power network reactors
Opis:
The article presents the principle of operation, design method, and results of laboratory and simulation tests of a 24-pulse power network converter system with direct-voltage output, the concept and practical realisation of which was worked out within the framework of a research project financed by the State Committee for Scientific Research. The presented converter allows significant reduction of undesirable higher harmonics in the power network current, including the elimination of harmonics of an order 23 and 25. The 24-pulse nature of operation of the system is obtained using three sets of coupled three-phase power network reactors (CTR).
Źródło:
Electrical Power Quality and Utilisation. Journal; 2005, 11, 1; 83-92
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rational determination of dynamic characteristics of fluid-flow reactors
Autorzy:
Sawicki, J. M.
Powiązania:
https://bibliotekanauki.pl/articles/241307.pdf
Data publikacji:
2005
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
fluid-flow reactors
waste treatment
dispersion
Opis:
A new model for water treatment and waste disposal reactors was developed. The startpoint to this model is a "triangular" approximation in the shape of the real flow-through curve. This approximation is defined by some characteristic points of time, which are strongly related to the characteristic velocities of wastewater. Combination of this simplified function with the kinetic equation of the reaction of the 1st order yields the sequence of the governing equations. Three practical examples show that the proposed "rational" model gives much better results than the traditional plug-flow model.
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2005, 52, 3; 177-193
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active method of three way catalyst monitoring by use of wideband combustion mixture composition sensor
Aktywna metoda monitorowania pracy trójfunkcyjnego reaktora katalitycznego z wykorzystaniem szerokozakresowego sensora składu mieszanki palnej
Autorzy:
Kruczyński, S.
Tomaszewski, D.
Kamela, W.
Powiązania:
https://bibliotekanauki.pl/articles/950108.pdf
Data publikacji:
2007
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
silniki spalinowe
sensory składu mieszanki palnej
diagnostyka pokładowa
reaktory katalityczne
zanieczyszczenie środowiska
combustion engines
combustion mixture composition sensors
on-board diagnostics
catalytic reactors
air pollution
Opis:
In this paper the active method of three way catalyst monitoring by use of wideband combustion mixture composition sensor was described. This method relays on three way catalyst activity decrease by determination of it oxygen capacity decrease monitoring. Determination of catalyst oxygen capacity decrease was done by comparison of signals from wideband and binary combustion mixture composition sensors. These sensors were mounted before and after investigated catalyst. In this paper was described the test bench in which modified catalyst was used. The catalyst was modified to simulate it activity decrease. Paper contains the investigation procedure and also static and dynamic characteristics of wideband combustion mixture composition sensor. A hand of received results the characteristic of binary combustion mixture composition sensor reaction time on combustion mixture change in function of reactor activity was determinate. From received results the index of reactor oxygen capacity decrease was also determinate. Received results showed also that this method can be used for precise controlling of three way catalysts activity for on board diagnostic systems purposes. Additionally this method allows concluding on toxic gases emission in NEDC tests at steady state engine work cycle.
Źródło:
Journal of KONES; 2007, 14, 4; 225-232
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of spark ignitrion engine warm up process on toxic gases conversion in three way catalyst
Wpływ procesu rozgrzewania się silnika o zapłonie iskrowym na konwersję substancji szkodliwych w trójfunkcyjnym reaktorze katalitycznym
Autorzy:
Kruczyński, S.
Danilczyk, W.
Kamela, W.
Powiązania:
https://bibliotekanauki.pl/articles/247879.pdf
Data publikacji:
2007
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
silniki spalinowe
emisja substancji szkodliwych
reaktory katalityczne
zimny rozruch silnika
zanieczyszczenie środowiska
combustion engines
toxic gases emission
catalytic reactors
engine warm up process
air pollution
Opis:
In his article the influence of deactivated three way catalyst on toxic gases conversion at engine warm up process was described. The test procedure and the test bench were described. The test bench was used to achieve catalytic reactor deactivation at laboratory conditions. The test procedure was chosen to achieve catalytic reactor deactivation same as at the real road conditions at the vehicle that traveled 100 000 kilometers. Paper contains results of toxic gases conversion at the new and deactivated reactors. This was made to estimate the influence of catalytic reactor aging on toxic gases conversion ability. Article also contains the results of toxic gases emission measured at the NEDC test. This measurement was also done with new and aged reactor mounted at the chosen vehicle exhaust pipe. Results from this test was used to estimate CO, HC and NOX conversion at aged catalytic reactor at the engine warm up process in all NEDC test cycles. Received results shown that toxic gases conversion at deactivated reactor decreases at range from 14 to 32% depending on chosen toxic substance. Examples of O2, CO2 and CO HC i NOX concentrations changes after catalyst at NEDC test, the CO, HC and NOX conversion changes In function of catalytic process temperature for New and deactivated catalysts, comparison of CO, HC and NOX conversion received at NEDC test and from simulation for new catalyst are presented in the paper.
W artykule przedstawiono wpływ obecności w układzie wydechowym pojazdu deaktywowanego reaktora katalitycznego na spadek konwersji substancji szkodliwych podczas zimnego rozruchu silnika. Opisano metodę oraz stanowisko hamowniane służące do deaktywowania reaktora katalitycznego na hamowni silnikowej. Przedstawiona metoda pozwoliła na deaktyację reaktora odpowiadającą przebiegowi 100 000 kilometrów w rzeczywistych warunkach eksploatacji reaktora katalitycznego w pojeździe. Przedstawiono wyniki pomiarów konwersji związków toksycznych w reaktorze nowym oraz po teście deaktywacji w celu określenia wpływu starzenia reaktora katalitycznego na jego zdolność do konwersji substancji szkodliwych. W artykule zamieszczono również wyniki badań uzyskane w trakcie pomiarów emisji substancji szkodliwych na hamowni podwoziowej, w teście NEDC pojazdu z nowym oraz deaktywowanym reaktorem katalitycznym. Określono konwersję CO, HC oraz NOx za deaktywowanym reaktorem umieszczonym w pojeździe, w trakcie rozgrzewania się silnika, w kolejnych fazach testu NEDC. Uzyskane wyniki wykazały spadek konwersji substancji szkodliwych, za daktywowanym reaktorem katalitycznym w zakresie od 14 do 32% w zależności od wybranego związku toksycznego. W artykule są zilustrowane przykładowe zmiany stężeń O2, CO2, CO, HC oraz NOx za reaktorem katalitycznym pojazdu w teście NEDC, zmiana konwersji CO, HC oraz NOx w funkcji temperatury pracy reaktora katalitycznego nowego oraz deaktywowanego, porównanie konwersji NOx uzyskanych w teście NEDC oraz w trakcie badań symulacyjnych nowego reaktora katalitycznego.
Źródło:
Journal of KONES; 2007, 14, 3; 319-329
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Catalytic properties analysis of platinum catalytic converters in self ignition engine exhaust gases
Analiza właściwości katalitycznych reaktorów platynowych do silników o zapłonie samoczynnym
Autorzy:
Kruczyński, S. W.
Kamela, W.
Mleczko, P.
Powiązania:
https://bibliotekanauki.pl/articles/244197.pdf
Data publikacji:
2008
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
silniki spalinowe
emisja substancji szkodliwych
reaktory katalityczne
zanieczyszczenie środowiska
combustion engines
toxic gases emission
catalytic reactors
air pollution
Opis:
In this article the catalytic properties comparison of four different platinum catalytic converters working in exhaust gases of self ignition engine were described. The test procedure and the test bench were described. Article contains structure of tested catalytic converters with physicochemical investigations of their active surface. The reactors surfaces views from scanning electron microscope (SEM) and x-ray surface structure investigations were also included. Comparison of tested catalytic converters properties were made in function of their temperature. Analyses were related to rector's ability to convert carbon monoxide, hydrocarbon, sum of nitric oxides, nitrogen monoxide and nitrogen dioxide. Results of investigations have shown that platinum catalytic converters working in diesel exhaust gases have high efficiency in oxidation of nitrogen monoxide to nitrogen dioxide. This property is mainly used in continuous regeneration trap systems (CRT). Catalytic converters ability to passive reduction of nitric oxides by use of hydrocarbons was demonstrated. Ranges of tested reactors temperature in which their properties that can be used in continuous regeneration trap systems and systems of selective nitric oxides reduction by use of hydrocarbons (HC-SCR) were defined. Mentioned reactors properties were estimated in connection to platinum load on reactors surface.
W artykule przedstawiono porównanie właściwości katalitycznych czterech reaktorów platynowych o różnym ładunku platyny pracujących w spalinach silnika o zapłonie samoczynnym. Artykuł zawiera opis stanowiska badawczego oraz procedurę badań. W pracy przedstawiona została budowa badanych modeli reaktorów katalitycznych i badania fizykochemiczne ich powierzchni aktywnych, w tym obrazy ze skaningowego mikroskopu elektronowego (SEM) oraz badania rentgenowskie struktury powierzchni. Porównania właściwości badanych reaktorów katalitycznych dokonano w funkcji temperatury ich pracy. Analiza dotyczyła zdolności reaktorów do konwersji tlenku węgla, węglowodorów, sumarycznego stężenia tlenków azotu, tlenku azotu oraz dwutlenku azotu. Wyniki badań wykazały, że reaktory platynowe pracujące w spalinach silnika o zapłonie samoczynnym wykazują dużą efektywność w utlenianiu tlenku azotu do dwutlenku azotu. Właściwość ta jest w szczególności wykorzystywana w systemach ciągłej regeneracji filtra cząstek stałych (CRT).Wykazano również zdolność tych rektorów do pasywnej redukcji tlenków azotu za pośrednictwem węglowodorów. Określono zakres temperatury pracy badanych reaktorów, przy których ujawniają się ich właściwości katalityczne możliwe do wykorzystania w systemach ciągłej regeneracji filtra cząstek stałych i systemach selektywnej redukcji tlenków azotu węglowodorami (HC-SCR). Oceniono wyżej wymienione właściwości reaktorów badawczych w zależności od ładunku platyny naniesionego na ich powierzchnię.
Źródło:
Journal of KONES; 2008, 15, 2; 247-256
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu optymalnego sterowania temperaturą w reaktorze okresowym na stopień przemiany
Analysis of the effect of optimum temperature control on conversion degree in a batch reactor
Autorzy:
Grubecki, I.
Wójcik, M.
Powiązania:
https://bibliotekanauki.pl/articles/2071711.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
dezaktywacja katalizatora
reaktory chemiczne
optymalizacja
optymalny profil temperatury
rachunek wariacyjny
catalyst deactivation
chamical reactors
optimization
optimal temperature profile
variation calculus
Opis:
W odniesieniu do reakcji Ť-tego rzędu przebiegającej w reaktorze okresowym w obecności katalizatora ulegającego dezaktywacji niezależnej od stężenia substratu przeanalizowano korzyści wynikające z zastosowania optymalnego profilu względem warunków izotermicznych wyrażone względnym przyrostem stopnia przemiany. Założono przy tym identyczność początkowej i końcowej aktywności zastosowanego katalizatora w rozważanych warunkach temperaturowych oraz równość czasów przebiegu procesu tj;w tych warunkach. Określono wpływ ilorazu energii aktywacji, końcowej aktywności katalizatora oraz rzędu reakcji n. Wykazano, że korzyści wynikające z zastosowania optymalnego profilu temperatury względem warunków izotermicznych wyrażone względnym przyrostem stopnia przemiany są tym bardziej znaczące im wyższa jest wartość ilorazu energii aktywacji oraz proces prowadzony jest do możliwie niskich wartości końcowych aktywności katalizatora. Dodatkowo wspomniane korzyści ulegają zwiększeniu wraz z obniżeniem rzędu reakcji n.
Advantages expressed by the relative increase of conversion resulting from the application of optimal temperature profile as compared to isothermal conditions have been considered with respect to the n-th order reaction carried out in a batch reactor in the presence of catalyst undergoing deactivation independently of substrate concentration. Identical initial and final state of the catalyst as well as reaction duration times and has been assumed. The effects of activation energy quotient, final catalyst activity and reaction order n have been determined. It has been proved that advantages resulting from the application of optimal temperature profile with respect to isothermal conditions expressed by the relative conversion increase are the more pronounced, the higher is value of the activation energy quotient and when the process is carried out till possibly low values of the final bio-catalyst activity. Additionally, the mentioned advantages increase with the decreasing of reaction order n.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 6; 5-7
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka zmian koncentracji beztlenowego osadu czynnego w reaktorze o przepływie pionowym
The change of concentration performance of suspended anaerobic sludge in the reactor with vertical flow
Autorzy:
Dudek, M.
Zieliński, M.
Grala, A.
Dębowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/399675.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
fermentacja metanowa
reaktory beztlenowe
ścieki mleczarskie
beztlenowy osad czynny
methane fermentation
anaerobic reactors
waste milk
suspension
flow
Opis:
W podjętych badaniach zajęto się wpływem wielkości obciążenia hydraulicznego na zdolność zatrzymywania zawiesin beztlenowego osadu czynnego w modelowym reaktorze. Badania dowiodły, że im wyższe obciążenie reaktora ładunkiem zanieczyszczeń i większy dobowy przepływ tym mniej zawiesiny pozostaje w układzie. Jednak dzięki kombinowanemu przepływowi ścieków w badanym reaktorze udaje się uzyskać na odpływie wartość ok. 1000 mg/dm3.
The research undertaken addresses the influence of size on the hydraulic load holding capacity of suspended anaerobic sludge in the reactor model. Studies have shown that the higher burden of pollution load of the reactor and increased daily flow of less suspension remains in the system. But thanks to combined flow of sewage in the test reactor, manage to get the value of the outflow of about l000 mg/dm3.
Źródło:
Inżynieria Ekologiczna; 2010, 22; 106-113
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność oczyszczania ścieków mleczarskich w reaktorze beztlenowym o przepływie pionowym
The efficiency of dairy wastewater treatment in the anaerobic reactor with vertical flow
Autorzy:
Grala, A.
Zieliński, M.
Dudek, M.
Dębowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/399673.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
fermentacja metanowa
reaktory beztlenowe
ścieki mleczarskie
stopień usunięcia ChZT
anaerobic digestion
anaerobic reactors
dairy wastewater
COD removal efficiency
Opis:
Prezentowane badania dotyczyły oceny sprawności usuwania zanieczyszczeń z syntetycznych ścieków mleczarskich za pomocą hybrydowego reaktora o przepływie pionowym. W trakcie badań udowodniono, iż eksploatacja reaktora beztlenowego o przepływie pionowym ze wzrastającym obciążeniem reaktora ładunkiem zanieczyszczeń przyczyniła się do systematycznego spadku sprawności usuwania związków organicznych (ChZT). Stwierdzono ponadto, że przy obciążeniu powyżej 3 kg ChZT/m3d następuje przeciążenie reaktora i załamanie procesu metanogenezy. Zaobserwowano również, że wraz ze spadkiem efektywności usuwania zanieczyszczeń malała zawartość metanu w biogazie.
Described experiment related to researches on the evaluation of the efficiency of removing contaminations from synthetic dairy waste water using a hybrid reactor with vertical flow. During the tests proved that the operation of the anaerobic reactor with vertical flow with the increasing organic loading rates (OLR) has contributed to the decline of the systematic removal of chemical oxygen demand (COD). Moreover, it was found that with a load of more than 3kg COD/m3d the reactor is going to overload and the process of methanegenesis will be stopped. It was also observed that, along with a decline in the effectiveness of removing contaminations methane content in biogas decreased.
Źródło:
Inżynieria Ekologiczna; 2010, 22; 97-105
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prediction of gas holdup in the three-phase fluidized bed: air/Newtonian and non-Newtonian liquid systems
Autorzy:
Sivakumar, V.
Senthilkumar, K.
Kannadasan, T.
Powiązania:
https://bibliotekanauki.pl/articles/778056.pdf
Data publikacji:
2010
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
zator gazowy
złoże fluidalne
ciecze nienewtonowskie
reaktor wielofazowy
hydrodynamika
gas holdup
fluidized beds
non-Newtonian liquids
multiphase reactors
hydrodynamics
Opis:
The application of the three-phase fluidization technology in wastewater treatment and other biochemical processes has been regularly addressed in the past decades. For the design and development of the threephase fluidized bed reactors, knowledge of the hydrodynamic parameter such as gas holdup is essential and hence in this paper an attempt has been made to study the effect of fundamental and operating variables on gas holdup. On the basis of the experimental results, a unified correlation has been developed to predict gas holdup in the fluidized bed using the Newtonian and the non-Newtonian liquids. The experimental results showed good agreement with those predicted according to the developed correlation.
Źródło:
Polish Journal of Chemical Technology; 2010, 12, 4; 64-71
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy bezpieczeństwa procesowego w zbiornikowych reaktorach z mieszadłem
Process safety issues in stirred tank reactors
Autorzy:
Lewak, M.
Molga, E.
Powiązania:
https://bibliotekanauki.pl/articles/2070850.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
bezpieczeństwo reaktorów
kryterium bezpieczeństwa
wykresy graniczne
safety of chemical reactors
safety criterion
boundary diagrams
Opis:
Celem prezentowanej pracy było opracowanie i weryfikacja uniwersalnego kryterium bezpiecznej pracy dla reaktora zbiornikowego o działaniu okresowym i półokresowym. Wykonano serię badań doświadczalnych mających na celu wyznaczenie i weryfikację wykresów granicznych, będących podstawą opracowania tego kryterium. Przeprowadzone badania doświadczalne i testy w pełni potwierdziły przydatność oraz dużą niezawodność opracowanego kryterium bezpieczeństwa.
The aim of this study was the elaboration and verification of universal criterion for safe operation of batch and semibatch stirred tank reactors. Series ' of experimental studies were carried out in the RC1 Mettler Toledo reaction calorimeter to determine and verify boundary diagrams on which this criterion is based. The carried out experiments fully confirm applicability and robustness of the elaborated criterion.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 1; 65-66
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of computer codes for modeling corrosion product transport and activity build-up in light water reactors
Autorzy:
Rafique, M.
Mirza, N. M.
Mirza, S. M.
Iqbal, M. J.
Powiązania:
https://bibliotekanauki.pl/articles/148648.pdf
Data publikacji:
2010
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
corrosion product
light water reactors
fuel cladding
radiation field
Opis:
The corrosion products are among the leading sources of radiation in primary coolant circuits of pressurized water reactors leading to prolongation of reactor down-time for routine maintenance entailing substantial loss of revenues. These deposits affect adversely coolant flow rates resulting in elevation of fuel and cladding temperature and become activated by high neutron flux in reactor core consequently creating high radiation field by accumulating in the out-of-core reactor components. In the case of light water reactors (LWRs), prevailing corrosion products include 59Fe, 99Mo, 56Mn, 58Co, and 60Co. The 56Mn is the leading corrosion product activity source during operation while cobalt isotopes dominate the activity after reactor shutdown. This paper presents a detailed discussion on some computer codes developed for prediction and transport of corrosion product activity in LWRs.
Źródło:
Nukleonika; 2010, 55, 3; 263-269
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utylizacja metanu z powietrza wentylacyjnego kopalń węgla kamiennego w termicznym reaktorze rewersyjnym
Utilization of methane contained in ventilation air from coal mine shafts in a thermal flow reversal reactor
Autorzy:
Gosiewski, K.
Pawlaczyk, A.
Jaschik, M.
Powiązania:
https://bibliotekanauki.pl/articles/2071196.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
VAM
TFRR
reaktory rewersyjne
spalanie niekatalityczne
metan
revers flow reactors
non-catalytic combustion
methane
Opis:
Omówiono problem utylizacji metanu zawartego w powietrzu wentylacyjnym kopalń węgla kamiennego (VAM - Ventilation Air Methane), poprzez jego niekatalityczne spalanie w termicznym reaktorze rewersyjnym (TFRR). Badany demonstracyjny reaktor pracował autotermicznie przy stężeniach wlotowych od 0,2% obj. CH4, z możliwością, odzysku ciepła od 0,4% obj. Wykazano, że przy stężeniach zbliżonych do 1% obj. możliwy jest odzysk co najmniej 5 MW, na 100 000 Nm powietrza wentylacyjnego.
The paper presents a problem of utilization of methane contained in ventilation air (VAM) from coal mine shafts through its non-catalytic combustion in the so-called thermal flow reversal reactors (TFRR). The research carried out in a demonstration reactor revealed that it could operate autothermi-cally for concentrations higher than 0.2 CH4 vol.% and with heat recovery above 0.4 vol.%. It was shown that for concentration approaching 1 vol.% the heat recovery at least 5 MW( for every 100 000 m3 (STP) of ventilation air is possible.
Źródło:
Inżynieria i Aparatura Chemiczna; 2010, 3; 37-38
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A diode rectifier with coupled reactor and small shunt power filter
Prostownik diodowy z dławikami sprzężnymi i małym równoległym filtrem aktywnym
Autorzy:
Mysiak, P.
Grugel, P.
Powiązania:
https://bibliotekanauki.pl/articles/194114.pdf
Data publikacji:
2011
Wydawca:
Politechnika Bydgoska im. Jana i Jędrzeja Śniadeckich. Wydawnictwo PB
Tematy:
energetyczne filtry aktywne
sieciowe trójfazowe dławiki sprzężone
wielopulsowy przekształtnik sieciowy
kondycjonowanie energii
active power filters
coupled three-phase power network reactors
local power network
multi-pulse grid converters
power conditioning
Opis:
The article describes the laboratory and simulation tests of 12- and 24- pulse power grid converter systems with DC voltage output that work together with shunt active power filter (APF). It presents both the operations' principles and the results of these tests. The systems under discussion make it possible to reduce the number of unwanted higher harmonics in the power network current. Moreover, they can also help eliminate the 23- and 25-order harmonics especially in the conditions of local power network supply. In order to obtain the multipulsed system's operation, a set of coupled three-phase power network reactors (CTR) has been used.
Artykuł zawiera wyniki badań symulacyjnych i testów laboratoryjnych 12- i 24- pulsowego przekształtnika sieciowego z wyjściowym obwodem napięcia stałego, pracującego z równoległym filtrem aktywnym. Omówione rozwiązanie pozwala znacząco zredukować występowanie niepożądanych harmonicznych prądu sieci, tym całkowicie wyeliminować harmoniczne rzędu 23 i 25. Wielopulsowa praca układu została osiągnięta poprzez zastosowanie zespołu trójfazowych dławików sprzężonych.
Źródło:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy; 2011, 16; 5-16
0209-0570
Pojawia się w:
Zeszyty Naukowe. Elektrotechnika / Uniwersytet Technologiczno-Przyrodniczy w Bydgoszczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A robust 18-pulse diode rectifier with coupled reactors
Autorzy:
Mysiak, P.
Strzelecki, R.
Powiązania:
https://bibliotekanauki.pl/articles/200065.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
series active power filters
multi-pulse rectifiers
coupled reactors
power conditioning
Opis:
The article presents the principle of operation and selected results of simulation and laboratory tests of the 18-pulse rectifier system with coupled reactors and small series active power filter. The presented system makes it possible to reduce, especially in distribution supply networks, undesired higher current harmonics. The 18-pulse nature of operation of the rectifier is reached using a set of coupled three-phase network reactors (CDT and CTR). The simultaneous use of the coupled reactors and the small active power filter provides opportunities for reduction of the supply current distortion, especially in case of voltage harmonic distortion and voltage unbalance.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2011, 59, 4; 541-550
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies