Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "reactive current" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Reactive compensator synthesis in time-domain
Autorzy:
Siwczyński, M.
Jaraczewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/201083.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power and energy theory
reactive power filters
reactive current
optimization
harmonic filter design
Opis:
The source reactive-current compensation is crucial in the energy transmission efficiency. The compensator design in a frequencydomain has already been widely discussed and examined. This paper presents results of a study on how to design reactive compensators in a time-domain. It is the first time the reactive compensator has been designed in a time domain. The example of a compensator is presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 1; 119-124
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Generation of the reactive current with the iterative algorithm aid
Generowanie prądu biernego wspomagane algorytmem iteracyjnym
Autorzy:
Mikołajuk, Kazimierz
Toboła, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/268578.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
reactive current
reactive power compensator
iterative control
prąd bierny
kompensator mocy biernej
sterowanie iteracyjne
Opis:
The iterative control of the power electronic compensator is presented. The method is based on the voltage measurement. The single phase DC/AC inverter with PWM control is considered. The inverter generates the reactive current shifted to voltage. The current amplitude is computed with the use the iterative algorithm based on Euler secant method. The required voltage amplitude is chosen as the objective function and the limits of the compensator current constitute the constraints. The simulation results for the circuit composed of the simple grid model and DC/AC inverter is presented. The DC/AC inverter with the series inductor realize the current source. The simulation are done with the use PLECS program. Sliding DFT seems to be adequate to compute the correct shift angle between voltage fundamental harmonic and compensator current. The simulation shows that the capacitor voltage connected at the DC side of inverter can be maintained by choosing of the power angle between the grid voltage and inverter voltage.
Przedstawiono koncepcję iteracyjnego sterowania układu wytwarzającego prąd bierny. Metoda opiera się na pomiarze napięcia sieci w węźle przyłączenia kompensatora. Rozpatrywany jest jednofazowy przekształtnik DC/AC ze sterowaniem PWM, realizujący sterowane źródło prądu sinusoidalnego przesuniętego względem pierwszej harmonicznej napięcia sieci. Amplituda wytwarzanego prądu jest obliczana z wykorzystaniem algorytmu iteracyjnego. Funkcją celu w tym algorytmie jest zadana wartość amplitudy podstawowej harmonicznej napięcia sieci. Zmienną poszukiwaną w procesie optymalizacji jest rzeczywisty współczynnik równy stosunkowi amplitudy generowanego sinusoidalnego prądu kompensatora do zmierzonej amplitudy podstawowej harmonicznej napięcia sieci. Pokazano możliwość wytworzenia sygnału sterującego przekształtnik AC/DC w kilku krokach metody iteracyjnej. Metodę tą można zakwalifikować do metod siecznych Eulera. Zaprezentowano wyniki symulacji komputerowych układu złożonego z uproszczonego modelu obwodowego sieci, przekształtnika DC/AC ze sterowaniem PWM oraz szeregowo włączoną cewką indukcyjną. Cewka indukcyjna umożliwia realizację źródła prądu i obliczenie sygnału sterującego przekształtnik. Symulacje wykonano z wykorzystaniem języka programowania PLECS. Pokazano możliwości podtrzymywania napięcia kondensatora włączonego po stronie DC przekształtnika za pomocą kąta mocy między napięciem sieci i napięciem przekształtnika.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 113-116
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physical Interpretation of the Reactive Power in Terms of CPC Power Theory Revisited
Autorzy:
Jeltsema, D.
van der Woude, J.
Powiązania:
https://bibliotekanauki.pl/articles/262600.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
power theory
reactive power
current’s physical
components
Opis:
Recently the authors have developed a time-domain representation of the Currents’ Physical Components (CPC) power theory. Consequently, piece-wise continuous currents and voltages, such as square waves and sawtooth signals, can naturally be taken into account without approximating them by a finite number of harmonics. Based on the time-domain CPC approach, this paper refines and corrects some of the assertions made by Czarnecki in his paper ‘Physical Interpretation of the Reactive Power in Terms of CPC Power Theory’.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2013, 16, 2; 1-6
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of the external proximity effect on the power losses in flat three phase high current busduct
Autorzy:
Piątek, Z.
Szczegielniak, T.
Kusiak, D.
Powiązania:
https://bibliotekanauki.pl/articles/97507.pdf
Data publikacji:
2011
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
active power
reactive power
Bessel function
three phase current busduct
Opis:
In the paper the influence of the external proximity effect on the active and reactive power in flat three phase high current busduct were presented. Calculations were made using the Poynting theorem and Joule-Lenz law.
Źródło:
Computer Applications in Electrical Engineering; 2011, 9; 34-44
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Novel Method of Improving Electrical Properties of Thin PECVD Oxide Films by Fluorination of Silicon Surface Region by RIE in RF CF4 Plasma
Autorzy:
Kalisz, M.
Głuszko, G.
Beck, R. B.
Powiązania:
https://bibliotekanauki.pl/articles/308057.pdf
Data publikacji:
2010
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
capacitance-voltage characteristics
current-voltage characteristics
fluorine plasma
radio frequency reactive ion etching
Opis:
This study describes a novel technique to form good quality low temperature oxide (< 350 C degree). Low temperature oxide was formed by N2O + SiH4:N2 plasma in a plasma enhanced chemical vapour deposition (PECVD) system on the silicon surface reactively etched in CF4 plasma (RIE - reactive ion etching). The fabricated oxide demonstrated excellent (for low temperature dielectric formation process) currentvoltage (I-V) characteristics, such as: low leakage current, high breakdown voltage and good reliability. Experimental results indicate that the proposed method of fluorine incorporation into the SiO2/Si inteface improves electrical parameters of MOS structures.
Źródło:
Journal of Telecommunications and Information Technology; 2010, 1; 20-24
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current limiting algorithm for three-phase grid-connected inverters
Autorzy:
Tran, Tho Quang
Powiązania:
https://bibliotekanauki.pl/articles/2135740.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current limitation
negative sequences
reactive power compensation
three-phase grid-connected inverter
unbalanced voltages
Opis:
Grid-connected inverters are commonly used in systems of renewable energy to convert this energy source into AC power with parameters suitable for connection to the grid. In the normal operating conditions, the grid-connected inverters mainly generate active power to the grid. However, when a voltage sag or voltage imbalance occurs, the grid voltage imbalance in the conventional control methods causes negative sequence components and increases the output current magnitude of inverters. The increase of current can damage power semiconductor devices. This paper presents a strategy to limit the current magnitude of inverters under unbalanced grid voltage conditions. In this strategy, a multiple-complex-coefficient filter is used to eliminate the negative sequence voltage components. This method does not require any additional hardware. A three-phase gridconnected photovoltaic inverter system using a solar array of 20 kWp is also used for the survey. The effectiveness has been validated when comparing the simulation results on Matlab/Simulink of the proposed method with those of the conventional method.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 559--579
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of High Temperature Annealing on Fluorine Distribution Profile and Electro-Physical Properties of Thin Gate Oxide Fluorinated by Silicon Dioxide RIE in CF4 Plasma
Autorzy:
Kalisz, M.
Głuszko, G.
Beck, R. B.
Powiązania:
https://bibliotekanauki.pl/articles/308059.pdf
Data publikacji:
2010
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
capacitance-voltage characteristics
current-voltage characteristics
fluorine plasma
high temperature annealing process
radio frequency reactive ion etching
Opis:
This study describes the effects of high temperature annealing performed on structures fluorinated during initial silicon dioxide reactive ion etching (RIE) process in CF4 plasma prior to the plasma enhanced chemical vapour deposition (PECVD) of the final oxide. The obtained results show that fluorine incorporated at the PECVD oxide/Si interface during RIE is very stable even at high temperatures. Application of fluorination and high temperature annealing during oxide layer fabrication significantly improved the properties of the interface (Ditmb decreased), as well as those of the bulk of the oxide layer (Qeff decreased). The integrity of the oxide (higher Vbd ) and its uniformity (Vbd distribution) are also improved.
Źródło:
Journal of Telecommunications and Information Technology; 2010, 1; 25-28
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Problemy kačestva èlektrosnabženiâ promyšlennyh potrebitelej ot obmotki srednego naprâženiâ tâgovyh podstancij peremennogo toka
Problemy jakości zasilania konsumentów przemysłowych z uzwojenia średniego napięcia podstacji trakcyjnych prądu przemiennego
The Problems of Power Quality for Industrial Consumers Fed on the Medium-voltage Winding from AC Traction
Autorzy:
Bosyj, D. A.
Powiązania:
https://bibliotekanauki.pl/articles/215440.pdf
Data publikacji:
2014
Wydawca:
Instytut Kolejnictwa
Tematy:
podstacja trakcyjna
prąd zmienny
napięcie
asymetria
moc bierna
kompensacja
traction substation
alternating current
voltage
unbalance
reactive power
compensation
Opis:
W pracy podstacji trakcyjnych prądu zmiennego może występować znaczące pogorszenie jakości energii elektrycznej. Z powodu obniżenia jakości energii elektrycznej, straty ponoszą przede wszystkim odbiorcy przemysłowi zasilani z uzwojenia średniego napięcia transformatora trakcyjnego. Wyniki przeprowadzonych badań potwierdzają teoretycznie znane problemy z jakością napięcia, a mianowicie zawyżenie napięcia w jednej z faz, róż-nicę napięć na sąsiednich podstacjach, odchylenie trójfazowego układu wektorów napięcia. Analiza znanych metod symetryzacji opartych na zjawisku Scotta wykazała, że założenie o równości kątów obciążenia w odcinkach zasilania, powoduje znaczący błąd w określeniu zjawiska symetryzującego, które nie jest wystarczające do spełnienia wymagań normy w zakresie asymetrii napięć. Zaproponowano rozwiązanie techniczne, które polega na udoskonaleniu urządzeń do ciągłej kompensacji mocy biernej i zapewnia normowaną wartość wskaźnika asymetrii napięcia przy jednoczesnym zmniejszeniu przepływów mocy biernej.
Working of AC traction substations involves significant distortion of the quality of electric energy. First of all, suffer from poor quality of electric power, industrial consumers, which feed on the medium-voltage winding of the traction transformer. Conducted measurements confirm the theory known problems with the quality of voltage that is overstating the voltage in one phase, the difference between the substations, wry three-phase system voltage vectors. Analysis of the known methods of balancing based on the Scott effect showed that the assumption of the equality of the angles at the shoulders load power is making a significant error in the determination of the symmetry effect, which is not enough to ensure the standard requirements regarding voltage unbalance. The proposed solution, which is to improve the devices continuously reactive power compensation and allows normal coefficient of voltage unbalance simultaneously with a reduction in reactive power flows.
Źródło:
Problemy Kolejnictwa; 2014, 162; 21-32
0552-2145
2544-9451
Pojawia się w:
Problemy Kolejnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics and monitoring of microprocessor-controlled excitation power supply unit for synchronous motors
Diagnostyka i monitorowanie pracy mikroprocesorowo sterowanego bloku zasilania wzbudzenia silnika synchronicznego
Autorzy:
Hyla, M.
Powiązania:
https://bibliotekanauki.pl/articles/1361379.pdf
Data publikacji:
2017
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
synchronous motor
excitation current control
reactive power controller
microprocessor control
remote control
monitoring
silnik synchroniczny
sterowanie prądem wzbudzenia
regulator mocy biernej
sterowanie mikroprocesorowe
zdalne sterowanie i monitorowanie
Opis:
This article presents a excitation power supply unit for synchronous motors with a microprocessor control system. The theoretical basics of reactive power regulation with a synchronous motor and influence of load on the permissible operating range are discussed. The possibilities of controlling the motor by a microprocessor system in the developed device during asynchronous start-up and synchronous operation are presented. The ability to monitor and record the status of the drive, which allows us to analyze the sequence of events in case of emergencies, is also presented. Dedicated software for diagnostic and service operation is demonstrated. The selected diagnostic functionality is also discussed.
W artykule przedstawiono blok zasilania wzbudzenia silników synchronicznych z mikroprocesorowym układem sterowania. Omówiono podstawy teoretyczne regulacji mocy biernej za pomocą silnika synchronicznego oraz wpływ obciążenia na dopuszczalny obszar pracy. Przedstawiono możliwości sterowania silnikiem przez system mikroprocesorowy opracowanego urządzenia podczas rozruchu asynchronicznego i pracy synchronicznej. Zaprezentowano możliwości monitorowania i rejestracji stanu pracy napędu pozwalające na analizę sekwencji zdarzeń w przypadku wystąpienia stanów awaryjnych. Przedstawiono dedykowane oprogramowanie diagnostyczno-serwisowe. Omówiono wybrane funkcje diagnostyczne.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2017, 55, 1; 19-25
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies