Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "radium equivalent" wg kryterium: Temat


Wyświetlanie 1-1 z 1
Tytuł:
Estimation of the Radiation Hazards Indices of Organic Fertilizers Using NaI(Tl) Gamma Spectrometer
Autorzy:
Baqir, Yassir Atta
Kadhim, Nada Farhan
Abdaljalil, Rana O.
Powiązania:
https://bibliotekanauki.pl/articles/1030492.pdf
Data publikacji:
2020
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
Organic fertilizer
external risk
gamma ray spectrometer
radium equivalent
specific activity
Opis:
Recently the use of organic fertilizers is increased to raise the agricultural products and reclaim land for cultivation in the world. These fertilizers contain many natural radionuclides, such as Uranium series (U-238), Thorium series (Th-232), and Potassium (K-40). Organic fertilizers can be considered as one of the natural sources of radiation in the soil. The specific activities of natural radionuclides U-238, Th-232, and K-40 in organic fertilizers were measured using a gamma-ray spectrometer NaI(Tl) detector and Rad Eye-B20 portable detector. Results of NaI(Tl) detector showed that the mean value of activity concentrations of U-238, Th-232, and K-40 was 2.101 Bq/kg, 0.329 Bq/kg, and 95.791 Bq/kg, respectively, were less than the recommended limits. The mean value of radiometric parameters Raeq, Hin, Hex, Iγ, Iɑ, DƔ, and AEDE were also calculated (9.398 Bq/kg, 0.0355, 0.0249, 0.037, 0.0123, 4.959 nGy/h, 0.0065 mSv/y). But the maximum and minimum values of activity concentration were found in sample O.2 and O.4, respectively. The results of Rad Eye-B20 portable detector showed that the maximum (0.415 Bq/cm2, 0.17 µSv/h, and 1.055 Cps) and the minimum (0.255 Bq/cm2, 0.13 µSv/h, and 0.485 Cps) values of surface contamination, Dose Rate, and General Count Rate per second were respectively found in samples O.2 and O.4; all they were slightly higher than background measurements (0.21 Bq/cm2, 0.12 µSv/h, and 0.44 Cps). Measurements of NaI(Tl) detector were matched and confirmed by Rad Eye-B20 detector. All measurements of the radiological hazard to consumers were less than the recommended limits.
Źródło:
World Scientific News; 2020, 144; 126-140
2392-2192
Pojawia się w:
World Scientific News
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies