Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "radiometry" wg kryterium: Temat


Tytuł:
Generalized radar/radiometry imaging problems
Autorzy:
Prudyus, I.
Voloshynovskiy, S.
Synyavskyy, A.
Holotyak, T.
Lazko, L.
Powiązania:
https://bibliotekanauki.pl/articles/309072.pdf
Data publikacji:
2001
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
radiometry systems
Synthetic Aperture Radar (SAR)
spatio-temporal imaging
Opis:
In the paper the results of spatio-temporal imaging simulation based on radar, synthetic aperture radar (SAR) and radiometry systems are presented. The analytical relationship between object scattering/emitting and the formed image is given and the general approach for the description of imaging system by means of Frendholm equation solution is developed. The potential limit of image resolution based on Rao-Cramer inequality is estimated.
Źródło:
Journal of Telecommunications and Information Technology; 2001, 4; 15-20
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Radiative Properties of a Red Phosphorus Based Combustion Flame
Autorzy:
Koch, Ernst-Christian
Powiązania:
https://bibliotekanauki.pl/articles/27788054.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
combustion flames
infrared radiation
red phosphorus
obscurants
phosphorus pentoxide
radiometry
Opis:
The spectral energy, Eλ (in J·g–1·sr–1), of a model obscurant composition containing red phosphorus (P(red), 59 wt.%), Zr (15 wt.%), potassium nitrate (KNO3, 21 wt.%) and a polyacrylate binder (5 wt.%), was determined in band II (λ = 3-5 μm) and band V (λ = 8-14 μm). The spectral energy obtained in band V was higher than the spectral energy in band II. The band ratio V/II and spectral energy indicated that the combustion flame of the pyrolant cannot be described as a graybody. A combined DTA/TG analysis under anaerobic conditions revealed an initial exotherm followed by an endothermic process, the latter coinciding with a mass loss of >40 wt.%, indicative of the vaporization of P(red).
Źródło:
Central European Journal of Energetic Materials; 2022, 19, 1; 5--17
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jak ocenić jakość fotometryczną ortofotomapy?
How to assess the photometric quality of the orthophotomap?
Autorzy:
Pyka, K.
Powiązania:
https://bibliotekanauki.pl/articles/129905.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
radiometria
fotometria
rozdzielczość
jakość
ortofotomapa
radiometry
photometry
resolution
quality
orthophoto
Opis:
Automatyzacja produkcji oraz stosunkowo niskie koszty opracowania powodują, że ortofotomapa stała się jednym z ważniejszych a być może najpopularniejszym produktem geoinformatycznym. W sytuacji masowego wykorzystywania ortofotomapy, co widać zwłaszcza w geoportalach internetowych, coraz większej wagi nabiera ocena jakości. O ile jakość geometryczna jest względnie łatwa do oceny to zgoła inaczej jest z jakością radiometryczną. W publikacji zwrócono uwagę na fakt, że w stosunku do ortofotomapy trafniej jest mówić o jakości fotometrycznej niż radiometrycznej. Dla uzasadnienia tezy opisano ogólną różnicę pomiędzy radiometrią a fotometrią a w szczególności przeanalizowano czym jest rozdzielczość radiometryczna a czym fotometryczna. W dalszej części pracy przedstawiono próbę kompleksowego zdefiniowania pojęcia jakość fotometryczna ortofotomapy. Uznano, że jakość fotometryczna ortofotomapy to stopień spełnienia przez obraz (o określonej rozdzielczości geometrycznej) szeregu warunków kształtujących jego przydatność do interpretacji treści. Następnie omówiono poszczególne warunki determinujące jakość fotometryczną podając każdorazowo możliwości ilościowej oceny spełnienia danego warunku.
The automation of the production and relatively low costs of development imply that the orthophotomap is one of the more important and probably the most popular geo-information technology product. Due to the global application of the orthophotomap as it is particularly evident in case of web geoportals, the quality assessment becomes more and more important. While the geometric quality is relatively easy to assess, it is far more difficult to rate the radiometric quality. The paper emphasises that it is more accurate to employ the term of the photometric quality instead of the radiometric quality in relation to the orthophotomap. In order to prove the thesis, general difference between the radiometry and the photometry was characterised and, in particular, the paper analysed the notions of the radiometric density and of the photometric density. Furthermore, the paper features the concept of the complex definition of the orthophotomap photometric quality. It has been accepted that the orthophotomap photometric quality is the ratio featuring in what way an image (of the specified geometric resolution) complies with a number of conditions defining its usability for the interpretation of the content. Thereafter, individual conditions determining the photometric quality are characterized, specifying each time whether it is possible to assess quantitatively the fulfilment of the given condition.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2009, 19; 363-372
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spatial distribution of radiogenic heat in the Iullemmeden basin – Precambrian basement transition zone, NW Nigeria
Autorzy:
Aisabokhae, Joseph
Adeoye, Moses
Powiązania:
https://bibliotekanauki.pl/articles/1841775.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
radiogenic heat
radiometry
geothermal exploration
basement complex
Iullemmeden basin
northwestern Nigeria
Opis:
The area which transcends the Precambrian basement complex onto the Sokoto sector of the Iullemmeden basin in northwestern Nigeria presents a unique prospect for geothermal exploration research in the absence of regional heat production data, despite its tectonic history and depositional characteristics. In this study, geophysical exploration employing radiometric technique was adopted to classify the petrologic units within the fringes of the Iullemmeden basin and the adjoining crystalline basement complex so as to estimate the radiogenic heat potential within the terrain that may support geothermal considerations. Airborne radiometric measurements acquired over the area were digitized and processed to obtain radioelement concentration maps and the K/Th/U ternary map. Results show that the ranges of measured concentrations of 40K, 238U and 232Th are 4.6 to 18.9%, 0.7 to 4.9 ppm and 4.6 to 18.9 ppm respectively. Radiogenic heat estimation derived from radioelement data within eight petrologic units comprising quaternary sediments, schist, carbonates, shale/clay, younger granites, older granites, gneissic rock and migmatite showed that the lowest radiogenic heat production estimates ranging from 0.27–0.66 µW∙m−3 were recorded in the sedimentary terrain within the quaternary sediments while the highest radiogenic heat production values of between 2.04 to 2.34 µW∙m−3 were recorded in the basement complex within gneissic rocks. The spatial distribution of radiogenic heat in the area showed an increased heat gradient within the basement complex and a diminishing heat gradient over the Iullemmeded basin.
Źródło:
Geology, Geophysics and Environment; 2020, 46, 3; 239-250
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microwave radiometry in monitoring and emergency mapping of water seepage and dangerously high groundwaters
Autorzy:
Shutko, A. M.
Haldin, A.
Krapivin, V.
Novichikhin, E.
Sidorov, I.
Tishchenko, Y.
Haarbrink, R.
Georgiev, G.
Kancheva, R.
Nikolov, H.
Coleman, T.
Archer, F.
Pampaloni, P.
Paloscia, S.
Krissilov, A.
Camps Carmona, A.
Powiązania:
https://bibliotekanauki.pl/articles/307666.pdf
Data publikacji:
2007
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
remote sensing
passive microwave radiometry
soil moisture
water seepage
risk assessment
Opis:
Detailed and geo-referenced maps identifying the locations of saturated and dry levees can be produced using microwave radiometric measurements from a light aircraft or helicopter, and integrated with GPS for positioning and orientation. The development of synergetic remote sensing technology for raised groundwater and seepage detection by the joint use of microwave and optical data along with GIS databases is an effective and most contemporary way of supporting risk assessment and facilitating disaster prevention and management. In this paper we present a remote sensing microwave technology for monitoring and detection of areas of water seepage through irrigation constructions, levees and dykes as well as for revealing areas with dangerously high groundwater level. The possibility for emergency response mapping, integrated with GPS and GIS data, facilitates the risk assessment and management services. The passive microwave radiometry (PMR) is based on spectral measurements in the millimetre to decimetre range of wavelengths. Compared to other remote sensing techniques, such as colour and infrared photography, thermal images and lidar, PMR is the only technology taking measurements under the earth's surface and therefore is very well suited for water seepage and underground water monitoring in a fast and reliable way.
Źródło:
Journal of Telecommunications and Information Technology; 2007, 1; 76-82
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spektrometryczne pomiary gamma rdzeni wiertniczych o niskiej aktywności
Spectrometric gamma measurements of low radioactivity cores
Autorzy:
Skupio, Rafał
Wolański, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1835068.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
promieniowanie gamma
pomiary rdzeni
radiometria
spektrometria
gamma radiation
core measurements
radiometry
spectrometry
Opis:
W pracy przedstawiono nową metodykę pomiarową spektrometrii gamma dla rdzeni wiertniczych reprezentowanych przez skały o niskiej aktywności. Opisano w niej części składowe nowo zaprojektowanego spektrometru wraz z dedykowanym oprogramowaniem testowym. Badania prowadzone według zaproponowanej procedury stosowane są głównie do rdzeni formacji piaskowcowych czerwonego spągowca, dla których dotychczas w Polsce nie wykonywano pomiarów gamma. Pierwsze testy na rdzeniach piaskowcowych prowadzono z wykorzystaniem standardowego spektrometru – gamma logger BGO (GL), przy wydłużonym czasie pomiarowym, co pozwoliło uzyskać zaledwie częściowe wyniki dla wybranego odcinka rdzenia. Opracowanie nowego urządzenia wykorzystującego dwa niezależnie mierzące detektory BGO, umieszczone pod kątem 90 stopni w ołowianym tunelu (aparatura GLGT) umożliwiło dwukrotne skrócenie czasu pomiarowego, poprawienie dokładności wyników oraz obniżenie poziomu detekcji dla analizowanych pierwiastków (potas, uran oraz tor). Wstępne badania porównawcze w otworze testowym ukazały różnice pomiędzy aparatem GL i GLGT. Polegały one na poprawie jakości rejestrowanych danych w szczególności dla uranu i toru, które w przypadku standardowych analiz przyjmowały wartości mniejsze od tła pomiarowego. Dodatkowe badania przeprowadzono na wzorcach kalibracyjnych w postaci walca o znanej koncentracji pierwiastków promieniotwórczych, których wyniki posłużyły głównie do oceny rozdzielczości obu metod. Seria pomiarów rdzeni z otworu J-1 pozwoliła otrzymać dokładne wyniki porównawcze z aparatów GL i GLGT, które przedstawiono na tle profilowań geofizyki otworowej oraz badań laboratoryjnych. W przypadku tego testu wyniki z aparatury GLGT wykazały się poprawą dokładności, lepszym dopasowaniem do profilowań oraz poprawą rozdzielczości pionowej w stosunku do geofizyki wiertniczej. Uzyskane wyniki pomiarów spektrometrem GLGT wykorzystano do określenia tła pomiarowego, szacunkowej rozdzielczości oraz określenia dokładnych zawartości potasu, uranu i toru w otworach archiwalnych. Wyniki końcowe przedstawiono w postaci krzywych spektrometrycznego profilowania gamma.
This paper shows a new methodology of gamma spectrometry measurements dedicated to cores represented by rocks of low radioactivity. It describes the components of the newely developed spectrometer and the dedicated testing software. The measurements conducted according to the proposed procedure are mostly applied for Rotliegend formation cores, for which spectral gamma core logging has never been done before in Poland. The first tests on the sandstone cores were conducted using a standard spectrometer – gamma logger BGO (GL) with an extended measurement time, which allowed obtain partial results for chosen core interval. The construction of the new device, which uses two independent BGO detectors placed at a 90-degree angle in lead tunnel shielding (GLGT apparatus), made it possible to twice shorten the measurement time, improve the accuracy of the results, and reduce the detection limit for the analysed elements (potassium, uranium, thorium). Preliminary comparative studies performed on the core from the test borehole showed differences between gamma logger GL and the GLGT device. These differences were visible especially for uranium and thorium data, which in the case of standard (GL) surveys carried values that were lower than the measurement background. Additional measurements were carried out on calibration standards in the form of a cylinder with a known concentration of radioactive elements, the results of which were used for evaluating the core logging resolution of both methods. The series of core measurements from J-1 borehole allowed to obtain accurate comparative results from GL and GLGT devices, which were presented against well logging and laboratory analyses. In the case of this test, the results from GLGT apparatus showed an improvement in measurement accuracy, better fitting to the well logs, and a higher vertical resolution in relation to spectral gamma logs. The results of the measurements performed with a GLGT spectrometer were used to define the measurement background, the estimated resolution, as well as to define the accurate content of potassium, uranium and thorium in the archival boreholes. All the final results were presented as curves of spectral gamma logs.
Źródło:
Nafta-Gaz; 2019, 75, 6; 324-329
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie termodyfuzyjności kryształów CdMgSe z wykorzystaniem techniki radiometrii w podczerwieni
Autorzy:
Pawlak, M.
Maliński, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/118430.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
termodyfuzyjność
kryształy półprzewodnikowe
CdMgSe
radiometria w podczerwieni
thermal diffusivity
semiconductor crystals
IR radiometry
Opis:
W pracy została wyznaczona termodyfuzyjność mieszanych kryształów półprzewodnikowych CdMgSe za pomocą radiometrii w podczerwieni. Badane próbki w obszarze widmowym pracy detektora są półprzepuszczalne dla promieniowania podczerwonego. Otrzymane wartości termodyfuzjności dla kryształów półprzewodnikowych CdMgSe za pomocą technik PPE i PTR różnią się w niewielkim stopniu.
In this paper the thermal diffusivities of CdMgSe mixed crystals were determined by means of the photothermal radiometry. Investigated samples are semi-transparent in the infrared range. Obtained results are in a reasonable agreement with those determined from the photopyroelectric technique (PPE).
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2013, 5; 55-62
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grain size in radiometric measurements of ground
Znaczenie rozmiarów ziaren w radiometrycznych pomiarach gruntu
Autorzy:
Gablin, V.
Powiązania:
https://bibliotekanauki.pl/articles/340347.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
radioaktywne skażenie gleby
radiometria
NORM
promieniotwórczość sztuczna
radioactive soil contamination
radiometry
norm
artificial radioactivity
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 75-76
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary promieniowania ludzi i obiektów za pomocą radiometru mikrofalowego
Measurements of human body and objects radiaton by means of microwave radiometer
Autorzy:
Stec, B.
Susek, W.
Rutkowski, A. K.
Powiązania:
https://bibliotekanauki.pl/articles/210626.pdf
Data publikacji:
2006
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
radiometria
radiometr mikrofalowy
termograf mikrofalowy
detekcja promieniowania
radiometry
microwave radiometer
microwave thermograph
detection of radiation
Opis:
W dziedzinie techniki zajmującej się pomiarami odebranego promieniowania wyróżnia się radiometrię szumową związaną z detekcją promieniowania o strukturze szumowej, którego widmo mieści się w paśmie mikrofalowym. Źródłem tego promieniowania są organizmy żywe oraz przedmioty i substancje, których temperatura jest wyższa od zera bezwzględnego. Pomiar tego rodzaju promieniowania jest realizowany za pomocą radiometru mikrofalowego składającego się z anteny (głowicy pomiarowej), wzmacniacza z detektorem oraz wyjściowego układu analizującego i rejestrującego. W artykule przedstawiono zasadę działania i parametry robocze radiometru modulacyjnego pracującego na częstotliwości 1,5 GHz. Opisano wybrane wyniki prac badawczych prowadzonych w Zakładzie Mikrofal IRE WEL WAT nad bezinwazyjnymi metodami lokalizacji stanów patologicznych wewnątrz organizmów żywych oraz biernymi systemami wykrywania obiektów o temperaturze fizycznej wyższej lub niższej niż temperatura ich otoczenia. Przedstawiono wyniki badań eksperymentalnych weryfikujących przyjęte hipotezy.
Microwave thermal radiation of various objects can be used for their location and identification. Thermovision in the infrared range enables us to find temperature distribution on the object surface while microwave radiometers allow us to recognize "hot" objects placed, for instance, behind thermal shields. Microwave radiometers are used, among the others, in health care and in so-called special applications. In medicine, they are used both in diagnostics and therapy where, for example, microwave radiometers control temperature in hypo- or hyperthermia or they can monitor pathological states of internal organs, detect pap tumour, or are used for temperature measurements of acupunctural points. Special applications of microwave radiometers focus on passive location of various equipment like tanks, planes, cars, trucks and so on. A separate group of applications deals with detection of humans or "hot" objects located behind shields. Performed experiments confirmed capability of developed radiometer to remote detection of live objects and subjects with temperatures different from the background. The tested instrument was equally effective in observation of non-shielded objects as well as for objects hidden behind dielectric shield. The principle of operation of the 1.5 GHz microwave radiometer and selected results of the experiments there were presented.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2006, 55, 1; 247-257
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spectrally tunable light source based on light-emitting diodes for custom lighting solutions
Autorzy:
Burgos-Fernandez, F. J.
Vilaseca, M.
Perales, E.
Herrera-Ramirez, J. A.
Martinez-Verdu, F. M.
Pujol, J.
Powiązania:
https://bibliotekanauki.pl/articles/173803.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
solid state lighting
light-emitting diodes
CIE standard illuminants
minimization algorithm
customized lighting design
radiometry
Opis:
This study describes a novel spectral LED-based tunable light source used for customized lighting solutions, especially for the reconstruction of CIE (Commission Internationale de l'Eclairage) standard illuminants. The light source comprises 31 spectral bands ranging from 400 to 700 nm, an integrating cube and a control board with a 16-bit resolution. A minimization algorithm to calculate the weighting values for each channel was applied to reproduce illuminants with precision. The differences in spectral fitting and colorimetric parameters showed that the reconstructed spectra were comparable to the standard, especially for the D65, D50, A and E illuminants. Accurate results were also obtained for illuminants with narrow peaks such as fluorescents (F2 and F11) and a high-pressure sodium lamp (HP1). In conclusion, the developed spectral LED-based light source and the minimization algorithm are able to reproduce any CIE standard illuminants with a high spectral and colorimetric accuracy able to advance available custom lighting systems useful in the industry and other fields such as museum lighting.
Źródło:
Optica Applicata; 2016, 46, 1; 117-129
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyka określania koncentracji pierwiastków promieniotwórczych frakcji pylastej wydzielonej z przedkarpackich utworów mioceńskich
Methodology for defining the concentration of radioactive elements in the silt fraction separated from Carpathian Foredeep Miocene formations
Autorzy:
Skupio, Rafał
Łykowska, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/1834054.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
silt
promieniowanie gamma
miocen
naturalna promieniotwórczość skał
radiometria
gamma ray
Miocene
natural radioactivity in rocks
radiometry
Opis:
The research was performed on seven samples of Miocene rocks collected from the core. The selected material was represented by sandstones, mudstones and claystones. The main goal of the work was to separate the silt fraction and to determine its impact on the level of radioactivity of the Miocene rocks of the Carpathian Foredeep. In this study, the silt fraction separation method developed in the Well Logging Department of INiG – PIB was used. Wentworth classification was used to determine the size of the silt, assuming its range from 4 to 63 µm. The selected rock material was prepared in several stages using the methods of freezing, sieving, centrifugation and sedimentation. Additional tests, including mineralogical XRD, chemical XRF and matrix density measurements were performed to determine the rock types and their properties. A number of radiometric tests were performed to determine the content of natural radioactive elements. The analyses were carried out on a small number of tests because of their long preparation and limited material availability. Reliable determination of the parameters of individual grain fractions required verification and improvement of the applied research methods. Radiometric measurements determining the natural content of potassium 40K, uranium 238U and thorium 232Th were carried out in the RT-50 equipped with a three-inch NaI(Tl) crystal. In the first place, standard analyses were conducted for dried and crushed samples of Miocene claystones, mudstones and sandstones. Further measurements were made on the separated silt fraction and in the case of one sample, also on the remaining fractions (clay and sand). In this case, the analyses were carried out repeatedly using a new procedure enabling the determination of radioactive elements in low-mass samples. The results of the work allowed approximate determination of the natural gamma radioactivity of the silt. An important conclusion is that, silt is no more radioactive than the other components of the rock. This paper also attempted the estimation of the impact of heavy mineral content on the natural radioactivity of the Miocene rocks. For tests purpose, minerals with a density above 2.85 g/cm3 were separated from the rock samples and a series of analyses were carried out once again. The obtained results were minimally understated but close enough to the samples before separation. It can be concluded that the heavy minerals in the tested samples do not affect the total radioactivity of the rocks in the research area.
Źródło:
Nafta-Gaz; 2020, 76, 10; 679-687
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies