Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "radiometria" wg kryterium: Temat


Tytuł:
Functionality assessment of algorithms for the coloring of images in terms of increasing radiometric values of aerial photographs archives
Ocena funkcjonalności algorytmów kolorowania obrazów w aspekcie zwiększenia walorów radiometrycznych archiwalnych zdjęć lotniczych
Autorzy:
Ewiak, I.
Siok, K.
Jenerowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/129725.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
digital image processing
black-and-white aerial photographs
coloring
radiometry
interpretation
cyfrowe przetwarzanie obrazów
monochromatyczne zdjęcia lotnicze
kolorowanie
radiometria
interpretacja
Opis:
Available on the commercial market are a number of algorithms that enable assigning to pixels of a monochrome digital image suitable colors according to a strictly defined schedule. These algorithms have been recently used by professional film studios involved in the coloring of archival productions. This article provides an overview on the functionality of coloring algorithms in terms of their use to improve the interpretation quality of historical, black-and-white aerial photographs. The analysis covered intuitive (Recolored) programs, as well as more advanced (Adobe After Effect, DaVinci Resolve) programs. The use of their full functionality was limited by the too large information capacity of aerial photograph images. Black-and-white historical aerial photographs, which interpretation quality in many cases does not meet the criteria posed on photogrammetric developments, require an increase of their readability. The solution in this regard may be the process of coloring images. The authors of this article conducted studies aimed to determine to what extent the tested coloring algorithms enable an automatic detection of land cover elements on historical aerial photographs and provide color close to the natural. Used in the studies were archival black-and-white aerial photographs of the western part of Warsaw district made available by the Main Centre of Geodetic and Cartographic Documentation, the selection of which was associated with the presence in this area of various elements of land cover, such as water, forests, crops, exposed soils and also anthropogenic objects. In the analysis of different algorithms are included: format and size of the image, degree of automation of the process, degree of compliance of the result and processing time. The accuracy of the coloring process was different for each class of objects mapped on the photograph. The main limitation of the coloring process created shadows of anthropogenic objects, where grey degree values were corresponding to forests.
Na rynku komercyjnym dostępnych jest szereg algorytmów umożliwiających przypisanie pikselom monochromatycznego obrazu cyfrowego odpowiednich barw według ściśle określonego schematu. Algorytmy te są wykorzystywane przez profesjonalne studia filmowe zajmujące się kolorowaniem archiwalnych produkcji. Niniejszy artykuł stanowi przegląd funkcjonalności algorytmów kolorowania w zakresie możliwości ich wykorzystania do poprawy jakości interpretacyjnej historycznych, monochromatycznych zdjęć lotniczych. Przedmiotem analiz były programy intuicyjne (Recolored), a także bardziej zaawansowane (Adobe After Effect, DaVinci Resolve). Ograniczeniem wykorzystania ich pełnej funkcjonalności była zbyt duża pojemność informacyjna obrazu zdjęcia lotniczego. W przypadku monochromatycznych historycznych zdjęć lotniczych, których jakość interpretacyjna w wielu przypadkach nie spełnia kryteriów stawianych opracowaniom fotogrametrycznym, istnieje potrzeba zwiększenia ich czytelności. Rozwiązaniem w tym zakresie może być proces kolorowania obrazów. Autorzy artykułu przeprowadzili badania zmierzające do ustalenia, w jakim zakresie testowane algorytmy kolorowania umożliwiają automatyczną detekcję elementów pokrycia terenu na historycznych zdjęciach lotniczych oraz nadanie im barwy zbliżonej do naturalnej. W badaniach zostały wykorzystane archiwalne monochromatyczne zdjęcia lotnicze powiatu warszawskiego zachodniego udostępnione przez Centralny Ośrodek Dokumentacji Geodezyjnej i Kartograficznej, których wybór wiązał się z występowaniem w ich obrębie różnorodnych elementów pokrycia terenu, takich jak: wody, lasy, uprawy rolne, odkryte gleby, a także obiekty antropogeniczne. W analizie poszczególnych algorytmów zostały uwzględnione: format i rozmiar obrazu, stopień automatyzacji procesu, stopień zgodności wyniku oraz czas przetworzenia. Dokładność procesu kolorowania była różna dla poszczególnych klas obiektów odwzorowanych na zdjęciu. Głównym ograniczeniem procesu kolorowania były cienie obiektów antropogenicznych, których wartości stopni szarości odpowiadały lasom.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2016, 28; 11-24
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Grain size in radiometric measurements of ground
Znaczenie rozmiarów ziaren w radiometrycznych pomiarach gruntu
Autorzy:
Gablin, V.
Powiązania:
https://bibliotekanauki.pl/articles/340347.pdf
Data publikacji:
2004
Wydawca:
Główny Instytut Górnictwa
Tematy:
radioaktywne skażenie gleby
radiometria
NORM
promieniotwórczość sztuczna
radioactive soil contamination
radiometry
norm
artificial radioactivity
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2004, 1; 75-76
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metody fototermiczne i ich zastosowania - Wykład inauguracyjny roku akademickiego 2019/2020 na Wydziale Elektroniki i Informatyki Politechniki Koszalińskiej
Autorzy:
Maliński, Mirosław
Powiązania:
https://bibliotekanauki.pl/articles/118355.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
fotoakustyka
metoda fototermiczna
modulowana absorpcja
swobodne nośniki
metoda piezoelektryczna
radiometria fototermiczna
photoacoustics
photothermal method
modulated free carrier absorption
piezoelectric method
photothermal radiometry
Opis:
Praca przedstawia metody fototermiczne jakie są stosowane w badaniach materiałów półprzewodnikowych w Katedrze Elektroniki Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej. W pracy przedstawiono również badawcze stanowiska fototermiczne w Katedrze, a także uzyskane wybrane charakterystyki doświadczalne.
This paper presents photothermal methods which are used in the research of semiconductor materials in the Department of Electronics of the Faculty of Electronics and Computer Science of the Koszalin University of Technology. In this paper the experimental photothermal research set ups of the Department as also the chosen obtained experimental characteristics are presented.
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2019, 15; 73-82
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termofalowa metoda pomiaru dyfuzyjności cieplnej
Thermal wave method for the determination of thermal diffusivity
Autorzy:
Mazur, J.
Pustelny, B.
Powiązania:
https://bibliotekanauki.pl/articles/257034.pdf
Data publikacji:
2008
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
dyfuzyjność cieplna
właściwości cieplne
metoda pomiarowa
fala termiczna
fotoakustyka
radiometria w podczerwieni
thermal diffusivity
thermal properties
measurement methods
thermal waves
photoacoustics
infrared radiometry
Opis:
W niniejszej pracy przedstawiono termofalową metodę pomiaru dyfuzyjności cieplnej z detekcją fotoakustyczną i radiometryczną. Opracowana procedura bazuje na pomiarze przesunięcia fazowego między sygnałami rejestrowanymi przez detektor a sygnałem sterującym modulacją źródła światła. Zastosowanie materiału referencyjnego pozwoliło na wyeliminowanie wpływu komponentów układu pomiarowego na rejestrowane przesunięcie fazowe.
This paper presents a proposition of the thermal wave method of measuring the thermal diffusivity by means of photoacoustic and infrared radiometry detection. The described procedure is based on the determination of the phase-shift between the light source and the registered signal. A reference material is used for the elimination of the measurement set-up contribution to phase.
Źródło:
Problemy Eksploatacji; 2008, 3; 177-187
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie metody radiometrycznej w poszukiwaniu ciał ilmenitowych w masywie Ślęży (Dolny Śląsk)
The use of radiometric methods in the prospecting for the ilmenite bodies in the Massif Ślęża (Lower Silesia)
Autorzy:
Muszer, A.
Maliszewski, M.
Firlit, G.
Powiązania:
https://bibliotekanauki.pl/articles/171208.pdf
Data publikacji:
2015
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
radiometria
poszukiwanie
kruszce
ilmenit
promieniowanie gamma
statystyka
roboty górnicze
ofiolit Ślęży
radiometric method
prospecting
ore minerals
ilmenite
gamma radiation
statistic
mining works
ophiolitic Massif Ślęża
Opis:
Zbadano możliwość zastosowania radiometrycznej metody pomiarów promieniowania gamma do poszukiwań ciał oraz skupień ilmenitowych w gabrach w rejonie góry Ślęży (Dolny Śląsk). Obróbka statystyczna pomiarów natężenia promieniowania gamma pozwoliła na zidentyfikowanie kierunku WSW-ENE występowania ciał ilmenitowych. Na podstawie opracowania rozkładu anomalii statystycznych wytypowano miejsca obecności ciał ilmenitowych w masywie ofiolitowym Ślęży. Wytypowane miejsca na zboczach góry Ślęży okazały się obszarem dawnej, przedwojennej prospekcji okruszcowania Ti-Fe. Ciała ilmenitowe wykazują makro i mikrorytmiczność typową dla masywów magmowych. Ich miąższość waha się od 5 cm do 10 m.
Radiometric method was used to search for ilmenite bodies in gabbroes in the area of the Ślęża Mt (Lower Silesia, the Strzegomiany-Kunów Zone). Statistical processing of gamma radiation measurements allowed us to identify the occurrence of WSW-ENE trending ilmenite bodies. The ilmenite bodies were found in the ophiolitic Massif Ślęża by means of the statistical anomalies distribution. The selected locations on the slopes of the Mount Ślęża proved to be an old, pre-WWII prospecting area of Ti-Fe mineralization. In the area of the Ślęża Massif the typical rhythm of macro- and microcrystallization of ilmenite characteristic for magmatic bodies was found. The ilmenite bodies occurring in the Strzegomiany - Kunów Zone are striking 60o-240o or 70o-250o and their thickness varies from 5 cm to 10 m.
Źródło:
Górnictwo Odkrywkowe; 2015, 56, 2; 137-145
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wyznaczanie termodyfuzyjności kryształów CdMgSe z wykorzystaniem techniki radiometrii w podczerwieni
Autorzy:
Pawlak, M.
Maliński, M. A.
Powiązania:
https://bibliotekanauki.pl/articles/118430.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
termodyfuzyjność
kryształy półprzewodnikowe
CdMgSe
radiometria w podczerwieni
thermal diffusivity
semiconductor crystals
IR radiometry
Opis:
W pracy została wyznaczona termodyfuzyjność mieszanych kryształów półprzewodnikowych CdMgSe za pomocą radiometrii w podczerwieni. Badane próbki w obszarze widmowym pracy detektora są półprzepuszczalne dla promieniowania podczerwonego. Otrzymane wartości termodyfuzjności dla kryształów półprzewodnikowych CdMgSe za pomocą technik PPE i PTR różnią się w niewielkim stopniu.
In this paper the thermal diffusivities of CdMgSe mixed crystals were determined by means of the photothermal radiometry. Investigated samples are semi-transparent in the infrared range. Obtained results are in a reasonable agreement with those determined from the photopyroelectric technique (PPE).
Źródło:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej; 2013, 5; 55-62
1897-7421
Pojawia się w:
Zeszyty Naukowe Wydziału Elektroniki i Informatyki Politechniki Koszalińskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jak ocenić jakość fotometryczną ortofotomapy?
How to assess the photometric quality of the orthophotomap?
Autorzy:
Pyka, K.
Powiązania:
https://bibliotekanauki.pl/articles/129905.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
radiometria
fotometria
rozdzielczość
jakość
ortofotomapa
radiometry
photometry
resolution
quality
orthophoto
Opis:
Automatyzacja produkcji oraz stosunkowo niskie koszty opracowania powodują, że ortofotomapa stała się jednym z ważniejszych a być może najpopularniejszym produktem geoinformatycznym. W sytuacji masowego wykorzystywania ortofotomapy, co widać zwłaszcza w geoportalach internetowych, coraz większej wagi nabiera ocena jakości. O ile jakość geometryczna jest względnie łatwa do oceny to zgoła inaczej jest z jakością radiometryczną. W publikacji zwrócono uwagę na fakt, że w stosunku do ortofotomapy trafniej jest mówić o jakości fotometrycznej niż radiometrycznej. Dla uzasadnienia tezy opisano ogólną różnicę pomiędzy radiometrią a fotometrią a w szczególności przeanalizowano czym jest rozdzielczość radiometryczna a czym fotometryczna. W dalszej części pracy przedstawiono próbę kompleksowego zdefiniowania pojęcia jakość fotometryczna ortofotomapy. Uznano, że jakość fotometryczna ortofotomapy to stopień spełnienia przez obraz (o określonej rozdzielczości geometrycznej) szeregu warunków kształtujących jego przydatność do interpretacji treści. Następnie omówiono poszczególne warunki determinujące jakość fotometryczną podając każdorazowo możliwości ilościowej oceny spełnienia danego warunku.
The automation of the production and relatively low costs of development imply that the orthophotomap is one of the more important and probably the most popular geo-information technology product. Due to the global application of the orthophotomap as it is particularly evident in case of web geoportals, the quality assessment becomes more and more important. While the geometric quality is relatively easy to assess, it is far more difficult to rate the radiometric quality. The paper emphasises that it is more accurate to employ the term of the photometric quality instead of the radiometric quality in relation to the orthophotomap. In order to prove the thesis, general difference between the radiometry and the photometry was characterised and, in particular, the paper analysed the notions of the radiometric density and of the photometric density. Furthermore, the paper features the concept of the complex definition of the orthophotomap photometric quality. It has been accepted that the orthophotomap photometric quality is the ratio featuring in what way an image (of the specified geometric resolution) complies with a number of conditions defining its usability for the interpretation of the content. Thereafter, individual conditions determining the photometric quality are characterized, specifying each time whether it is possible to assess quantitatively the fulfilment of the given condition.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2009, 19; 363-372
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyka określania koncentracji pierwiastków promieniotwórczych frakcji pylastej wydzielonej z przedkarpackich utworów mioceńskich
Methodology for defining the concentration of radioactive elements in the silt fraction separated from Carpathian Foredeep Miocene formations
Autorzy:
Skupio, Rafał
Łykowska, Grażyna
Powiązania:
https://bibliotekanauki.pl/articles/1834054.pdf
Data publikacji:
2020
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
silt
promieniowanie gamma
miocen
naturalna promieniotwórczość skał
radiometria
gamma ray
Miocene
natural radioactivity in rocks
radiometry
Opis:
The research was performed on seven samples of Miocene rocks collected from the core. The selected material was represented by sandstones, mudstones and claystones. The main goal of the work was to separate the silt fraction and to determine its impact on the level of radioactivity of the Miocene rocks of the Carpathian Foredeep. In this study, the silt fraction separation method developed in the Well Logging Department of INiG – PIB was used. Wentworth classification was used to determine the size of the silt, assuming its range from 4 to 63 µm. The selected rock material was prepared in several stages using the methods of freezing, sieving, centrifugation and sedimentation. Additional tests, including mineralogical XRD, chemical XRF and matrix density measurements were performed to determine the rock types and their properties. A number of radiometric tests were performed to determine the content of natural radioactive elements. The analyses were carried out on a small number of tests because of their long preparation and limited material availability. Reliable determination of the parameters of individual grain fractions required verification and improvement of the applied research methods. Radiometric measurements determining the natural content of potassium 40K, uranium 238U and thorium 232Th were carried out in the RT-50 equipped with a three-inch NaI(Tl) crystal. In the first place, standard analyses were conducted for dried and crushed samples of Miocene claystones, mudstones and sandstones. Further measurements were made on the separated silt fraction and in the case of one sample, also on the remaining fractions (clay and sand). In this case, the analyses were carried out repeatedly using a new procedure enabling the determination of radioactive elements in low-mass samples. The results of the work allowed approximate determination of the natural gamma radioactivity of the silt. An important conclusion is that, silt is no more radioactive than the other components of the rock. This paper also attempted the estimation of the impact of heavy mineral content on the natural radioactivity of the Miocene rocks. For tests purpose, minerals with a density above 2.85 g/cm3 were separated from the rock samples and a series of analyses were carried out once again. The obtained results were minimally understated but close enough to the samples before separation. It can be concluded that the heavy minerals in the tested samples do not affect the total radioactivity of the rocks in the research area.
Źródło:
Nafta-Gaz; 2020, 76, 10; 679-687
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spektrometryczne pomiary gamma rdzeni wiertniczych o niskiej aktywności
Spectrometric gamma measurements of low radioactivity cores
Autorzy:
Skupio, Rafał
Wolański, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1835068.pdf
Data publikacji:
2019
Wydawca:
Instytut Nafty i Gazu - Państwowy Instytut Badawczy
Tematy:
promieniowanie gamma
pomiary rdzeni
radiometria
spektrometria
gamma radiation
core measurements
radiometry
spectrometry
Opis:
W pracy przedstawiono nową metodykę pomiarową spektrometrii gamma dla rdzeni wiertniczych reprezentowanych przez skały o niskiej aktywności. Opisano w niej części składowe nowo zaprojektowanego spektrometru wraz z dedykowanym oprogramowaniem testowym. Badania prowadzone według zaproponowanej procedury stosowane są głównie do rdzeni formacji piaskowcowych czerwonego spągowca, dla których dotychczas w Polsce nie wykonywano pomiarów gamma. Pierwsze testy na rdzeniach piaskowcowych prowadzono z wykorzystaniem standardowego spektrometru – gamma logger BGO (GL), przy wydłużonym czasie pomiarowym, co pozwoliło uzyskać zaledwie częściowe wyniki dla wybranego odcinka rdzenia. Opracowanie nowego urządzenia wykorzystującego dwa niezależnie mierzące detektory BGO, umieszczone pod kątem 90 stopni w ołowianym tunelu (aparatura GLGT) umożliwiło dwukrotne skrócenie czasu pomiarowego, poprawienie dokładności wyników oraz obniżenie poziomu detekcji dla analizowanych pierwiastków (potas, uran oraz tor). Wstępne badania porównawcze w otworze testowym ukazały różnice pomiędzy aparatem GL i GLGT. Polegały one na poprawie jakości rejestrowanych danych w szczególności dla uranu i toru, które w przypadku standardowych analiz przyjmowały wartości mniejsze od tła pomiarowego. Dodatkowe badania przeprowadzono na wzorcach kalibracyjnych w postaci walca o znanej koncentracji pierwiastków promieniotwórczych, których wyniki posłużyły głównie do oceny rozdzielczości obu metod. Seria pomiarów rdzeni z otworu J-1 pozwoliła otrzymać dokładne wyniki porównawcze z aparatów GL i GLGT, które przedstawiono na tle profilowań geofizyki otworowej oraz badań laboratoryjnych. W przypadku tego testu wyniki z aparatury GLGT wykazały się poprawą dokładności, lepszym dopasowaniem do profilowań oraz poprawą rozdzielczości pionowej w stosunku do geofizyki wiertniczej. Uzyskane wyniki pomiarów spektrometrem GLGT wykorzystano do określenia tła pomiarowego, szacunkowej rozdzielczości oraz określenia dokładnych zawartości potasu, uranu i toru w otworach archiwalnych. Wyniki końcowe przedstawiono w postaci krzywych spektrometrycznego profilowania gamma.
This paper shows a new methodology of gamma spectrometry measurements dedicated to cores represented by rocks of low radioactivity. It describes the components of the newely developed spectrometer and the dedicated testing software. The measurements conducted according to the proposed procedure are mostly applied for Rotliegend formation cores, for which spectral gamma core logging has never been done before in Poland. The first tests on the sandstone cores were conducted using a standard spectrometer – gamma logger BGO (GL) with an extended measurement time, which allowed obtain partial results for chosen core interval. The construction of the new device, which uses two independent BGO detectors placed at a 90-degree angle in lead tunnel shielding (GLGT apparatus), made it possible to twice shorten the measurement time, improve the accuracy of the results, and reduce the detection limit for the analysed elements (potassium, uranium, thorium). Preliminary comparative studies performed on the core from the test borehole showed differences between gamma logger GL and the GLGT device. These differences were visible especially for uranium and thorium data, which in the case of standard (GL) surveys carried values that were lower than the measurement background. Additional measurements were carried out on calibration standards in the form of a cylinder with a known concentration of radioactive elements, the results of which were used for evaluating the core logging resolution of both methods. The series of core measurements from J-1 borehole allowed to obtain accurate comparative results from GL and GLGT devices, which were presented against well logging and laboratory analyses. In the case of this test, the results from GLGT apparatus showed an improvement in measurement accuracy, better fitting to the well logs, and a higher vertical resolution in relation to spectral gamma logs. The results of the measurements performed with a GLGT spectrometer were used to define the measurement background, the estimated resolution, as well as to define the accurate content of potassium, uranium and thorium in the archival boreholes. All the final results were presented as curves of spectral gamma logs.
Źródło:
Nafta-Gaz; 2019, 75, 6; 324-329
0867-8871
Pojawia się w:
Nafta-Gaz
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektronicznie sterowany generator szumów odniesienia radiometru mikrofalowego
Electronically controlled generator of reference noise for microwave radiometer
Autorzy:
Stec, B.
Susek, W.
Powiązania:
https://bibliotekanauki.pl/articles/210635.pdf
Data publikacji:
2006
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
radiometria mikrofalowa
generator szumów
pomiar temperatury
microwave radiometer
noise generator
temperature measurement
Opis:
W artykule przedstawiono rozwiązanie generatora szumów, w którym występuje możliwość zmiany wartości gęstości widmowej mocy generowanego sygnału. Taki generator wykorzystywany jest między innymi w układach mikrofalowych radiometrów zrównoważonych jako źródło sygnału odniesienia. Prezentowany generator szumów charakteryzuje się wysoką stabilnością generowanej mocy oraz ma możliwość elektronicznej regulacji jej poziomu. Artykuł zawiera także dyskusję niepewności określenia temperatury szumów wyjściowych sterowanego elektronicznie generatora szumów. Na zakończenie zaprezentowano wyniki pomiarów eksperymentalnych, potwierdzające poprawność przeprowadzonych analiz.
In the paper, a design of noise generator with a possibility of a changing generated signal value by spectral power density is presented. The generator can be used, among others, in balanced radiometers as a reference source. The presented noise generator is characterized by high stability of output power which can be electronically controlled. Experimental results are also shown. Noise generator is a source of stationary random signals. Those signals are commonly used for measurements of noise parameters of electronic systems like noise factor or effective input noise temperature. These sources can be usually characterized by constant spectral power density of a signal, defined by ENR (Excess Noise Ratio) parameter. There exist also the systems which need stable generators of reference noise (Fig. 1), capable of changing the ENR parameter value during a standard operation. Balanced radiometers are the systems which enable us also reception and measurement of thermal radiation in a microwave range. The structure of the noise generator includes primary source of a random course, shaping system both for random values and correlation function (spectral power density) distributions, and a system for determining a level of generated signal and output impedance value as well. A block diagram for the generator is shown in Fig. 2. Primary source of noise is a resistor maintained in a constant temperature. Thermal noise generated in the resistor is then gained in a microwave amplifier with the systems both for thermal and power supply stabilization. Stabilization systems minimize gain fluctuations of the amplifier at the level of 10 (relative fluctuations) for amplifier operation in the band L and gain of 15 dB. The attenuators minimize an influence of the PIN reflection attenuator on operation of primary noise source and on matching at the generator output. The PIN adjustable attenuator changes values of noise power depending on polarization current passing through PIN diodes. The presented in the paper noise generator can be used both in measurements for noise parameters of electronic systems and as a noise source with variable spectral power density for microwave radiometry. The generator operates in 0.5-5 GHz frequency range and its noise temperature can be changed from 300 to 320 K with 0.1 K resolution. Its crucial feature is a capability of electronic control of power level of generated noise with the uncertainty of temperature value setting lower than 0.3 K. Generator design fairly meets requirements for reference noise sources of microwave radiometers, namely control of generated signal level, small setting time of generated signal, and high precision and resolution of output noise temperature settings.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2006, 55, 1; 233-246
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies