Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "radiator" wg kryterium: Temat


Tytuł:
The Development and Numerical Analysis of the Conical Radiator Extrusion Process
Autorzy:
Michalczyk, J.
Powiązania:
https://bibliotekanauki.pl/articles/352073.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
extrusion radiator
conical radiator
Opis:
The article presents a newly developed method for single-operation extrusion of conical radiators. This is the author’s radiator manufacturing method being the subject of a patent application. The proposed method enables the manufacture of radiators either with or without an inner opening and with an integral plate. Selected results of numerical computations made within Forge®3D, a finite element method (FEM)-based software program, were presented during the analysis of the process. A comparative analysis of the proposed manufacturing method using the double-sided extrusion method was also made. The proposed manufacturing method is assumed to produce radiators in a single technological operation with the stock material being standardized 30 mm-diameter aluminium bars. The objective of the developed method is also to reduce the energy-force parameters.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 4; 2267-2272
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczanie wydajności układu chłodzenia ON-AN transformatora energetycznego średniej mocy
Calculation of efficiency of ON-AN cooling system on mid power transformer
Autorzy:
Bródka, B.
Sapała, J.
Łopatkiewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/376965.pdf
Data publikacji:
2015
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
transformator
radiator
układ chłodzenia ON-AN
Opis:
W artykule zawarto wyniki wstępnych prac, mających na celu opracowanie narzędzia obliczeniowego służącego do wyznaczania wydajności układu chłodzenia transformatora energetycznego średniej mocy. Do rozważań przyjęto transformatory o naturalnym obiegu oleju i naturalnym obiegu powietrza (ON-AN). Jako przykładową jednostkę obrano transformator o mocy 10 MVA (110/15 kV) produkcji firmy Power Engineering w Czerwonaku. Wyniki obliczeń porównano z wynikami próby nagrzewania transformatora, podczas zwarcia pomiarowego, wykonanej w fabryce. Ze względu na skomplikowany kształt elementów konstrukcyjnych transformatora (kadź, radiatory, część aktywna), narzędzie obliczeniowe wykorzystuje geometrię w przestrzeni. Wymiary wszystkich elementów otrzymano od producenta transformatora. Geometrię transformatora odpowiednio uproszczono w celu ograniczenia złożoności obliczeń. Obliczenia wykonano przy użyciu oprogramowania COMSOL Multiphysics. Opracowane narzędzie obliczeniowe obejmuje jedynie zjawisko konwekcji i przejmowania ciepła z uzwojeń do oleju a następnie z oleju do ścianek kadzi i radiatorów. Ze względu na dużą zbieżność wyników obliczeń z wynikami próby nagrzewania, narzędzie obliczeniowe będzie rozwijane i poprawiane w przyszłości. W publikacji zawarte zostały dalsze kierunki prac.
Results of preliminary calculation efficiency of ON-AN transformer cooling system are shown in the article. The results are shown for transformer 10 MVA. The transformer was produced in Power Engineering in Czerwonak. The results was compared with results of temperature-rise type test made in factory. Calculation was made as 3D model. All geometrical parameters was obtained from manufacturer of transformer. Geometry of transformer was simplified to made calculation less complex. Software COMSOL Multiphysics was used for the calculation. Convection and heat transfer from windings to oil and from oil to walls of radiators was only used in this calculations. In view of large convergence of calculation results and temperature-rise type test results the calculation tool will revise and expand.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2015, 82; 227-233
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Temperature Distribution Analysis on the Surface of the Radiator: Infrared Camera and Thermocouples Results Comparison
Autorzy:
Kotrys-Działak, Dagmara
Stokowiec, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/27315743.pdf
Data publikacji:
2023
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
radiator
thermal analysis
thermal imaging
thermocouples
Opis:
The experiments conducted in a didactic laboratory of the Kielce University of Technology involved temperature distribution measurements on the outer surface of a steel radiator using a thermal imaging camera and thermocouples to compare both investigation methods. The research included registering the parameters for a specific period for each of the four different medium flows. Graphs present the results with the division of the radiator into eight thermal fields. The results present the differences in temperatures between 1.78°C to 3.65°C. The non-contact method with an infrared camera seems more accurate since it is precise for surface temperature measurement.
Źródło:
Rocznik Ochrona Środowiska; 2023, 25; 37--44
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Non-invasive methods in diagnosis of wall dampness degree in sacral buildings
Nieinwazyjne metody diagnostyki stopnia zawilgocenia murów obiektów sakralnych
Autorzy:
Szczotka, J.
Powiązania:
https://bibliotekanauki.pl/articles/329520.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
brick walls
dampness
thermographic method
electromagnetic radiator
infrared radiator
mur ceglany
zawilgocenie
metoda termograficzna
promiennik podczerwieni
promiennik elektromagnetyczny
Opis:
The article contains a description of sacral buildings wall dampness causes. It shows the optimal condition of internal microclimate regarding rooms designed to exhibit historical items. Analysed methods are diagnostic of wall moisture by non-invasive methods. The thermal image examination with the use of microwave electromagnetic radiator was carried out. Two samples of brick were tested; they were exposed to the radiation at the total time of 90 seconds. The nominal power of the radiator was PN=900W. The author analysed other sources of heat radiation. He changed microwave radiation to infrared radiator, and thus the examination was easier and safer. The results shown in the article are the temperatures and infrared radiator test results. The aim is to determine time constant of various radiator work methods. The aim of the analysis was to show temperature distribution at given distances from the radiator, which enabled constant temperature distribution at certain stages of the device running.
W artykule zamieszczono opis przyczyn zawilgocenia murów z cegły ceramicznej obiektów sakralnych. Przedstawiono optymalne warunki mikroklimatu pomieszczeń przeznaczonych do ekspozycji obiektów zabytkowych. Poddano analizie metody diagnostyki zawilgocenia murów metodami nieinwazyjnymi. Przeprowadzono termograficzne pomiary laboratoryjne z wykorzystaniem mikrofalowego promiennika elektromagnetycznego. Badaniom poddano dwie próbki cegieł, które wystawiono na oddziaływanie promieniowania w całkowitym czasie 90s za pomocą manometru. Moc znamionowa promiennika wynosiła PN=900W. Autor poddał analizie inne źródło promieniowania cieplnego, zastąpił promieniowanie mikrofalowe promiennikiem podczerwieni, co ułatwia pomiary i zwiększyło bezpieczeństwo całego pomiaru. W artykule zamieszczono wynik temperatur i badań promiennika podczerwieni w celu wyznaczenia stałych czasowych przy różnych sposobach jego pracy. Celem badania było zobrazowanie rozkładu temperatur w założonych odległościach, co umożliwiło ukazanie bryłowego rozkładu temperatury w danych chwilach pracy urządzenia.
Źródło:
Diagnostyka; 2018, 19, 2; 63-69
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Research of Temperature Distribution on the Surface of the Front Plate, of a Flat Plate Heat Exchanger
Badania eksperymentalne rozkładu temperatury na powierzchni płyty czołowej płaskiego, płytowego wymiennika ciepła
Autorzy:
Orłowska, Magdalena
Powiązania:
https://bibliotekanauki.pl/articles/1811588.pdf
Data publikacji:
2020
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
radiator
temperature
convection
isothermal
grzejnik
temperatura
konwekcja
izotermiczność
Opis:
The purpose of the work was to perform experimental tests on a plate heat exchanger. For this purpose, a laboratory test stand located in the hall of the Koszalin University of Technology was used. The experiment concerned checking the isothermal face of a flat panel radiator. Temperature distributions were checked at three board heights and in twelve finite elements. Temperature distribution fields were obtained depending on the flow rates tested.
Celem pracy było wykonanie badań eksperymentalnych na płytowym wymienniku ciepła. W tym celu wykorzystano laboratoryjne stanowisko badawcze zlokalizowane w sali Politechniki Koszalińskiej. Eksperyment dotyczył sprawdzenia izotermicznej powierzchni płaskiego grzejnika płytowego. Rozkłady temperatury sprawdzono na trzech wysokościach płyty i w dwunastu elementach skończonych. W zależności od badanych natężeń przepływu uzyskano pola rozkładu temperatury.
Źródło:
Rocznik Ochrona Środowiska; 2020, Tom 22, cz. 1; 256-264
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ sprawności promienników podczerwieni na koszt zużycia energii
The Influence of Infrared Heaters Efficiency on the Energy Consumption Cost
Autorzy:
Dudkiewicz, E.
Fidorów, N.
Jeżowiecki, J.
Powiązania:
https://bibliotekanauki.pl/articles/1819089.pdf
Data publikacji:
2013
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
sprawność promienników
zużycie energii
infrared radiator
energy consumption cost
Opis:
Gas-fired infrared radiators become more widely used in large-space buildings. This is due to the way of use of the hall, distribution of work stations and the heat upward lifting in convection heating. Despite the advantages of gas-fired radiators and significant savings in comparison to other heating systems, the breach of thermal conditions and thermal discomfort of workers is often observed as the result of the incorrect selected number and power of the devices. Majority of designers take into consideration a heat power of radiators not the power of radiation send towards occupied zone. Efficiency of radiators without or with poor radiating screen insulation equals 45 to 55%. As the result the installed heating power should be twice greater than calculated heating load. Unfortunately most producers do not provide the radiation efficiency of devices. This results from the necessity of execution of expensive examinations according to the PN-EN 419-2 standard, that are not conducted in Poland. Some radiators with radiation efficiency as high as 80% appeared on the market. Their price is over twice higher than low efficient radiators. Three types of radiators, taking in account radiation efficiency, have been selected for calculation example. Their gas consumption during heating season have been compared. Cumulative cost analysis have been performed for those systems for two fuel tariffs. The analysis showed that the choice of tariff influence the heating costs for chosen type of radiators. The investment with high initial cost, because of high price of more efficient system starts to pay back after three years. Moreover in the article the rules for selection of ceramic gas-fired radiators and definitions of efficiencies have been given and the methodology of the radiation efficiency examination, according to the PN-EN 419-2 standard, have been described.
Źródło:
Rocznik Ochrona Środowiska; 2013, Tom 15, cz. 2; 1804-1817
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of alternative cutter paths on flatness deviations in the face milling of aluminum plate parts
Autorzy:
Dobrzynski, M.
Chuchala, D.
Orlowski, K. A.
Powiązania:
https://bibliotekanauki.pl/articles/99859.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
process precision
face milling
radiator
paths strategies
flatness deviation
Opis:
In this paper the relationships between the alternative machining paths and flatness deviations of the aluminum plate part, were presented. The flatness tolerance of the main surface of the plate part has crucial meaning due to the assembly requirement of piezoelectric elements on the radiator. The aluminum bodies under investigation are the base part of the radiators with crimped feathers for the train industry. The surface of the aluminum plate part was milled using three different milling strategies: along of longer or shorter side of workpiece and at an angle of 45°. The aluminum bodies were machined on milling centre ecoMILL 70 DMG MORI. The flatness deviation measurements were carried out on the Coordinated Measuring Machine Altera 7.5.5 Nikon Metrology NV. These measurements were made during the manufacturing process of the radiator, namely after machining, however, before the process crimping of feathers. The results that were obtained enables the validation of assumed milling path strategies in connection of the subsequent machining and assembly processes.
Źródło:
Journal of Machine Engineering; 2018, 18, 1; 80-87
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis and Optimization of Micro Speaker-Box Using a Passive Radiator in Portable Device
Autorzy:
Jiang, Y.-W.
Kwon, J.-H.
Kim, H.-K.
Hwang, S.-M.
Powiązania:
https://bibliotekanauki.pl/articles/176530.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
passive radiator
speaker box
SPL improvement
Sound Pressure Level
Opis:
With the rapid development of multimedia devices such as smart phones and tablet PCs, microspeakers have been recently increasingly used for audio equipment. Improving the acoustic performance of a microspeaker is always a main concern, especially in the low frequency range. To avoid sound cancelation, a microspeaker unit is usually inserted into a speaker box. A passive radiator is also used in speaker boxes to improve the sound performance in the loudspeaker system. However, passive radiators have not been applied into microspeaker system. In this study, a speaker box with a passive radiator was analyzed and optimized to achieve a higher Sound Pressure Level (SPL) in a microspeaker system. The Finite Element Method (FEM), two-degree-of-freedom (DOF) vibration theory, and a plane circular piston sound source were used to study the electromagnetic, vibration, and acoustic characteristics, respectively. Optimization was conducted by changing the mass, stiffness, and size of the passive radiator. Based on the optimized parameters, a new sample was manufactured. The experiment results show that the SPL of the optimized speaker box with a passive radiator is improved by 5 dB at 200 Hz compared with the one without a radiator. The analysis results also matched the experiment results.
Źródło:
Archives of Acoustics; 2017, 42, 4; 753-760
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical study of car radiator using dimple roughness and nanofluid
Autorzy:
Thapa, Robin Kumar
Bisht, Vijay Singh
Bhandari, Prabhakar
Rawat, Kamal Singh
Powiązania:
https://bibliotekanauki.pl/articles/2134933.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer
augmentation
nanofluid
pumping power
car radiator
artificial roughness
Opis:
Thermal augmentation in flat tube of car radiator using different nanofluids has been performed more often, but use of artificial roughness has been seldom done. Artificial roughness in the form of dimple is used in the present research work. Present study shows the impact of dimple shaped roughness and nanofluid (Al2O3/pure water) on the performance of car radiator. The pitch of dimples is kept at 15 mm (constant) for all the studies performed. The Reynolds number of the flow is selected in the turbulent regime ranging from 9350 to 23 000 and the concentration of the nanofluid is taken in the range of 0.1–1%. It has been found that the heat transfer rate has improved significantly in dimpled radiator tube on the expense of pumping power. Furthermore, the heat transfer rate also increases with increase in nanoparticle concentration from 0.1% to 1.0%. The highest heat transfer enhancement of 79% is observed at Reynolds number 9350, while least enhancement of 18% is observed for Reynolds number of 23 000.
Źródło:
Archives of Thermodynamics; 2022, 43, 3; 125--140
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jarzeniowy promiennik CO2
Glow radiator CO2
Autorzy:
Kubicki, J.
Powiązania:
https://bibliotekanauki.pl/articles/408374.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
promiennik
dwutlenek węgla
absorpcja promieniowania
radiator
carbon dioxide
absorption of radiation
Opis:
W pracy przedstawiono podstawy fizyczne zbudowanego modelu promiennika jarzeniowego CO2 emitującego promieniowanie podczerwone o częstotliwościach dokładnie pokrywających się z widmem absorpcji dwutlenku węgla. Opisano podstawowe badania tego modelu i podano interpretację fizyczną otrzymanych wyników. Zwrócono uwagę na własności emitowanego przez to urządzenie promieniowania oraz na możliwości wykorzystania urządzenia w różnych dziedzinach.
The paper presents the physical basis of the constructed model of the fluorescent emitter of CO2 emitting infrared radiation with frequencies exactly coinciding with the absorption spectrum of carbon dioxide. This study describes the basic model and given a physical interpretation of the results. Attention is paid on the properties of the emitted radiation by the device and the ability to use the device in various field.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 1; 16-20
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calculations of Electric Fields of Circular Screened Systems, Generated from Cylindrical Piezoceramic Radiators
Autorzy:
Leiko, Aleksandr
Derepa, Anatolii
Rasstrygin, Aleksandr
Kosiakovskyi, Andrii
Kocharian, Oksana
Starovoit, Yaroslav
Powiązania:
https://bibliotekanauki.pl/articles/176548.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
electric fields
circular system with baffle
piezoceramic cylindrical radiator
circular polarization
Opis:
Analytical relations, describing the electrical fields of cylindrical piezoceramic radiators with circular polarization as a member of the cylindrical systems with the baffle in the inner cavity, using the related fields method in multiply connected regions were obtained. Comparative analysis of the results of numerical experiments performed on the frequency characteristics of the electric field of the radiating systems for different modes of radiation allow to establish a number of subtle effects of the formation of the electric field of radiators.
Źródło:
Archives of Acoustics; 2019, 44, 1; 129-135
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical study of heat transfer and aerodynamic drag of the radiator with lamellar split finning
Autorzy:
Nikolaenko, Yurii
Baranyuk, Aleksandr
Rohachov, Valerii
Terekh, Aleksandr
Powiązania:
https://bibliotekanauki.pl/articles/240301.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
microelectronic devices
radiator
lamellar-split finning
heat transfer
aerodynamic resistance
numerical simulation
Opis:
Promising cooling systems for high-power electronic elements are those based on vapor chambers and heat pipes which allow for the local heat flow to be dispersed from the electronic element to a larger surface area of the vapor chamber or the heat pipe. To reduce the thermal resistance of the cooling system, a finned radiator is installed on the outer surface of the vapor chamber or heat pipe. The authors propose a new design of the radiator which increases the heat transfer efficiency. The paper presents results of numerical simulation of heat transfer and aerodynamic resistance of the heat transfer surface with lamellar-split finning. The comparative analysis of heat transfer and aerodynamics was carried out for three types of radiators: with lamellar smooth finning, with lamellar split finning and with the sections of split finning rotated 30◦ against the air flow. It is shown that cutting the fins and rotating the split sections leads to an increase in heat transfer intensity and increase in aerodynamic resistance. The obtained results may be useful in the design of cooling systems for computer processors, power amplifiers for transmitting modules, energy-saving solid-state light sources, etc.
Źródło:
Archives of Thermodynamics; 2020, 41, 1; 67-93
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical Analysis of the Influence of the Angle of Inclination of the Screen on the Intensity of Heat Exchange from a Flat Heat Exchanger in a Partially Limited Space
Analiza numeryczna wpływu kąta pochylenia ekranu na intensywność wymiany ciepła od płaskiego wymiennika ciepła w przestrzeni częściowo ograniczonej
Autorzy:
Orłowska, Magdalena
Szkarowski, Aleksander
Mamedov, Shirali
Powiązania:
https://bibliotekanauki.pl/articles/1811752.pdf
Data publikacji:
2019
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
radiator
heat transfer coefficient α
convection
inclination
grzejnik
współczynnik przejmowania ciepła α
konwekcja
pochylenie
Opis:
The purpose of the work was to perform a numerical analysis enabling to learn the influence of the angle of inclination of a flat partition placed at the plate heat exchanger on the thermal efficiency of the device. It turns out that the inclination of the partition affects this efficiency. Selected systems allowed to capture these changes in the studied range and to visualize them graphically.
Celem pracy było wykonanie analizy numerycznej umożliwiającej poznanie wpływu kąta pochylenia przegrody płaskiej umieszczonej przy płytowym wymienniku ciepła na wydajność cieplną urządzenia. Okazuje się, że pochylenie przegrody ma wpływ na tą wydajność. Wybrane układy pozwoliły uchwycić te zmiany w badanym zakresie i zobrazować graficznie.
Źródło:
Rocznik Ochrona Środowiska; 2019, Tom 21, cz. 1; 728-737
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu właściwości termicznych okna na pracę grzejnika w pomieszczeniu – badania numeryczne
Study of the Influence of Window Thermal Properties on Radiator Work in the Room – Numerical Research
Autorzy:
Orłowska, M.
Powiązania:
https://bibliotekanauki.pl/articles/1813767.pdf
Data publikacji:
2018
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
grzejnik
okno
współczynnik przejmowania ciepła α
konwekcja
radiator
window
heat transfer coefficient α
convection
Opis:
Celem pracy było wykonanie badań numerycznych konwekcyjnej wymiany ciepła. Analizy numeryczne przeprowadzono w układzie dwuwymiarowym. Zrealizowano je przy użyciu nowoczesnego programu komputerowego Ansys Mechanical CFD-Flo. Wymiana ciepła dotyczyła pokojowego grzejnika płytowego, płaskiego umieszczonego na ścianie z oknem. Utworzono kilka wariantów obliczeń. Zadano pięć, różnych wartości współczynnika przejmowania ciepła α na oknie. Na podstawie przeprowadzonych badań można stwierdzić jakie są różnice wartości temperatury oraz prędkości powietrza przy różnych, zadanych wartościach strumienia ciepła na oknie oraz jak kształtuje się współczynnik przejmowania ciepła α, decydujący o intensywności wymiany ciepła.
The purpose of the work was to perform numerical tests of convective heat exchange. Numerical analyzes were carried out in a two-dimensional system. They were realized using the modern Ansys Mechanical CFD-Flo computer program. The heat exchange concerned a room-mounted flat plate heater mounted on a wall with a window. Several calculation options have been created. Five different values of the heat transfer factor α on the window were given. On this basis of the conducted tests it is possible to determine the differences in temperature and air velocity at different values of the heat flux on the window and how the heat transfer coefficient α is determined which determines the intensity of heat exchange.
Źródło:
Rocznik Ochrona Środowiska; 2018, Tom 20, cz. 2; 1699-1709
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania numeryczne wpływu zabudowy grzejnika konwekcyjnego półką poziomą z zakrzywieniem na rozkład pól temperatury i prędkości powietrza w pomieszczeniu
Research on the Impact of a Curved Horizontal Shelf over Radiator on the Distribution of Air Temperature and Velocity Fields
Autorzy:
Orłowska, M.
Szkarowski, A.
Janta-Lipińska, S.
Powiązania:
https://bibliotekanauki.pl/articles/1813829.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
grzejnik
współczynnik przejmowania ciepła α
wymiana ciepła
radiator
heat transfer coefficient α
heat exchange
Opis:
Celem pracy było wykonanie badań numerycznych płytowego wymiennika ciepła obudowanego półką poziomą z zakrzywieniem. Dzisiejsze możliwości komercyjnych programów komputerowych są imponujące. Obliczenia wykonano przy użyciu kodu obliczeniowego Ansys Flotran. Dzięki niemu można symulować przepływy przy zadanych warunkach brzegowych. W przyszłości autorka pragnie poszerzyć badania o weryfikację obliczeń numerycznych na stanowisku pomiarowym laboratoryjnym. Artykuł traktuje o zabudowie płytowych wymienników ciepła. Są to najbardziej popularne i wykorzystywane obecnie w c.o. typy grzejników. Istnieje ich cała gama a rozmaite wymiary, kolory, efekty wizualne oraz duża bezwładność cieplna decydują o wyborze. Często grzejniki takie montowane są wg warunków montażowych osób je instalujących. Nie zawsze przynoszą oczekiwany efekt cieplny. Niekiedy niewłaściwy montaż lub przysłonięcie może wiązać się ze zmniejszeniem efektywności – wydajności cieplnej. Mowa tutaj nie tylko o meblach czy osłonach je przysłaniających ale również o bardzo popularnych półkach poziomych – parapetach. Parapety mają różne głębokości i szerokości. Wykonywane są z rozmaitych materiałów, np. plastik czy marmur. Bywa, że posiadają zakrzywienia krawędzi. Pojawia się pytanie jak tego typu konstrukcje wpływają na efekt cieplny – wydajność grzejnika? W artykule przedstawiono wybrane wyniki badań numerycznych dotyczących konwekcyjnego wymiennika ciepła. Wymiennik obudowano poziomą płytą z zakrzywieniem (rys. 1). Uzyskano pola temperatury i prędkości – rysunki 2-5. Na ich podstawie wyznaczono współczynnik przejmowania ciepła α, który decyduje o intensywności wymiany ciepła. Okazało się, że zakrzywienie i obudowanie grzejnika parapetem niekorzystnie wpływa na rozkład współczynnika przejmowania ciepła α. Dlatego też korzystniejszy jest układ bez półki poziomej. Decydując się na obudowę powinniśmy zwrócić uwagę na tego typu elementy ozdobne i przemyśleć warunki montażowe aby w pełni wykorzystać możliwości grzewcze wymiennika ciepła.
Main objective of this work was to perform numerical studies with heat exchanger covered in horizontal shelves. Today's possibilities of commercial computer programs are impressive. Calculations were performed using the simulation code Ansys Flotran. One can simulate flows under the given boundary conditions. In the future, the author wants to expand the study to verify the numerical calculations on the laboratory measuring station. This article concerns plate heat exchangers. These are the most popular and currently used in c.h. types of heaters. There are a whole range of different sizes, colors, visual effects and high thermal inertia determine the choice. Very often, such heaters are installed according to installation conditions. Sometimes, improper installation or cover may be associated with decreased heat output efficiency. This applies not only to furnitures but also a very popular horizontal shelves – window sills, which have different depths and width and they are made of various materials, for example – plastic or marble. Sometimes, they have a curvature of the edge. The question is, how this type of structures influence the thermal effect – the performance of the radiator? This article presents selected results of numerical research on the convective heat exchanger. Heat was encased in a horizontal plate with curvation – Fig. 1. Temperature field, velocity and air density – Fig. 2-5. were obtained. heat transfer coefficient α, which determines the intensity of heat exchange was set on that basis. It turned out that the curvature of the enclosure and heater sill affects the distribution of the heat transfer coefficient α. Therefore, no horizontal shelf is preferred. we should pay attention to this type of decorative elements and think about mounting conditions to take full advantage of the heat exchanger when we deciding on the cover.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 590-599
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies