Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "quantitative ultrasound" wg kryterium: Temat


Wyświetlanie 1-5 z 5
Tytuł:
A spectral-based method for tissue characterization
Autorzy:
Wójcik, J.
Byra, M.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/331796.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
quantitative ultrasound
signal analysis
wave scattering
Opis:
Quantitative ultrasound methods are widely investigated as a promising tool for tissue characterization. In this paper, a novel quantitative method is developed which can be used to assess scattering properties of tissues. The proposed method is based on analysis of oscillations of the backscattered echo power spectrum. It is shown that these oscillations of the power spectrum are connected with the distances between scatterers within the medium. Two techniques are proposed to assess the scatterer’s distribution. First, we show that the inverse Fourier transform of the backscattered echo power spectrum corresponds to a histogram of the distances between scatterers. Second, the Hilbert-Huang transform is used to directly extract the power spectrum oscillations. Both methods are examined by means of a numerical experiment. A cellular gas model of a biological medium is considered. Results are presented and discussed. Both methods can be used to evaluate the scatterer’s distribution by means of the power spectrum oscillations.
Źródło:
Hydroacoustics; 2016, 19; 369-375
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differentiation of the breast lesions using statistics of backscattered echoes
Autorzy:
Piotrzkowska-Wroblewska, H.
Dobruch-Sobczak, K.
Litniewski, J.
Chrapowicki, E.
Roszkowska-Purska, K.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/332342.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Akustyczne
Tematy:
quantitative ultrasound
breast cancer
Nakagami distribution
K distribution
Opis:
The purpose of this study was to evaluate the accuracy of statistical properties of the backscattered ultrasound in differential diagnosis of the breast lesions. The B-mode images, together with the appropriate RF echoes from the breast lesions and surrounding tissues were collected. The RF data was processed for the statistics of the backscattered echo signals, using K and Nakagami distributions characterized by the M and m parameters, respectively. Based on both, M and m parameters, a set of 18 parameters was derived. From the point of view of the sensitivity of detection of cancer, the best score was obtained using maximum value of M parameter, the best specificity was received using the differential Nakagami parameter (the differential values between lesions and surrounding tissues). In conclusion, quantitative sonography is a method which has potential to be a complementary tool for classification of the breast lesions.
Źródło:
Hydroacoustics; 2016, 19; 319-328
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using Empirical Mode Decomposition of Backscattered Ultrasound Signal Power Spectrum for Assessment of Tissue Compression
Autorzy:
Byra, M.
Wójcik, J.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177950.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
tissue characterization
tissue compression
quantitative ultrasound
empirical mode decomposition
signal analysis
Opis:
Quantitative ultrasound has been widely used for tissue characterization. In this paper we propose a new approach for tissue compression assessment. The proposed method employs the relation between the tissue scatterers’ local spatial distribution and the resulting frequency power spectrum of the backscattered ultrasonic signal. We show that due to spatial distribution of the scatterers, the power spectrum exhibits characteristic variations. These variations can be extracted using the empirical mode decomposition and analyzed. Validation of our approach is performed by simulations and in-vitro experiments using a tissue sample under compression. The scatterers in the compressed tissue sample approach each other and consequently, the power spectrum of the backscattered signal is modified. We present how to assess this phenomenon with our method. The proposed in this paper approach is general and may provide useful information on tissue scattering properties.
Źródło:
Archives of Acoustics; 2018, 43, 3; 447-453
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skeletal status in subjects with poor visual acuity in independent and institutionalized subjects
Stan szkieletu u osób z niedowidzeniem mieszkających samodzielnie oraz w domach opieki
Autorzy:
Drozdzowska, Bogna
Pluskiewicz, Wojciech
Lyssek-Boroń, Anita
Czekajło, Aleksandra
Wiktor, Katarzyna
Adamczyk, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1039253.pdf
Data publikacji:
2010
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
bone densitometry
poor vision
quantitative ultrasound
densytometria
niedowidzenie
ilościowa metoda ultradźwiękowa
Opis:
AIM The aim of the study was to evaluate skeletal status in subjects with poor vision. MATERIAL AND METHODS Skeletal status was assessed in a group of subjects with poor visual acuity living independently in general community or institutionalized in a nursing home. A group of 91 subjects (47 females - 29 living independently and 18 from nursing home and 44 males - 19 and 25, respectively) were studied. Mean age was 61.3+/-16.8 y. in females and 61.4+/-10.9 y. in males. Binocular visual acuity was evaluated using a Snellen acuity chart. Skeletal status was assessed by dual-energy X-ray absorptiometry at the calcaneus and forearm using PIXI (Lunar, USA) which measures bone mineral density (BMD) and by quantitative ultrasound at hand phalanges using DBM Sonic 1200 (IGEA, Italy) measuring Amplitude-dependent Speed of Sound (Ad-SoS [m/s]). RESULTS Binocular visual acuity was 0.179+/-0.2 in females and 0.09+/-0.14 in males and was signifi cantly lower in males (p<0.01). A visual acuity did not correlate with skeletal variables in either of sexes and was signifi - cantly lower in males from nursing home in comparison to males living independently (p<0.001) what was not observed in females. Z-scores were used in order to obtain age-adjusted comparisons of skeletal variables between subjects living independently and in nursing home. In females Z-scores for forearm (-0.304+/-0.92 vs –1.044+/-0.74, p<0.01) and calcaneus (-0.017+/-0.97 vs –1.38+/-0.63, p<0.00001) were significantly higher in individuals living independently than in nursing home, and Z-score for Ad-SoS did not diff er significantly. In males no signifi cant differences in Z-scores were noted. CONCLUSION The results of the study suggest that in both genders fracture risk in institutionalized subjects may be increased; in females due to affected skeletal status, and in males as a consequence of poor vision.
CEL PRACY Celem pracy była ocena stanu szkieletu u osób z niedowidzeniem. MATERIAŁ I METODY Stan szkieletu oceniano w grupie osób żyjących samodzielnie oraz mieszkańców domów pomocy społecznej (DPS). Zbadano 91 osób (47 kobiet – 29 mieszkających samodzielnie i 18 z DPS -ów oraz 44 mężczyzn – odpowiednio 19 i 25). Średni wiek to 61,3+/-16,8 u kobiet i 61,4+/-10,9 lat u mężczyzn. Obuoczną ostrość wzroku badano przy pomocy tablicy Snellena. Badania szkieletu obejmowały pomiar densytometryczny przy pomocy dwuwiązkowej absorpcjometrii rentgenowskiej (DXA) pięty i przedramienia (Lunar, USA) oraz pomiar metodą ultradźwiękową paliczków dłoni DBM Sonic 1200 (IGEA, Italy), mierząc prędkość fali ultradźwiękowej zależnej od amplitudy (Amplitude-dependent Speed of Sound (Ad-SoS [m/s]). WYNIKI Obuoczna ostrość wzroku wyniosła 0,179+/-0,2 u kobiet i 0,09+/-0,14 u mężczyzn i była istotna statystycznie mniejsza u mężczyzn (p<0,01). Ostrość wzroku nie korelowała z parametrami szkieletowymi i była istotnie niższa u mężczyzn z DPS-ów w porównaniu do mężczyzn żyjących samodzielnie (p<0,001), czego nie zanotowano u kobiet. Z-score, jako parametr niezależący od wieku zastosowano dla porównania. U kobiet Z-score przedramienia (-0,304+/-0,92 versus –1,044+/-0,74, p<0,01) i pięty (-0,017+/-0,97 versus –1,38+/-0,63, p<0,00001) były istotnie wyższe u kobiet żyjących samodzielnie względem kobiet z DPS-ów, a Z-score dla Ad-SoS nie różnił się. U mężczyzn brak było różnic ze względu na miejsce zamieszkania. WNIOSKI Wyniki pracy sugerują, że u kobiet i mężczyzn żyjących w domach opieki społecznej ryzyko złamań może być zwiększone; u kobiet w wyniku zaburzeń szkieletu, a u mężczyzn w efekcie niedowidzenia.
Źródło:
Annales Academiae Medicae Silesiensis; 2010, 64, 1-2; 16-21
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of Power Ultrasound to Chemical Dissolution for Quantitative Analysis of Cotton and Polyester Blended Fabrics
Zastosowanie ultradźwięków do rozpuszczania chemicznego w celu ilościowej analizy tkanin bawełnianych i poliestrowych
Autorzy:
Mingxing, Z.
Zhuo, M.
Yize, S.
Zhibiao, Y.
Powiązania:
https://bibliotekanauki.pl/articles/232993.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
power ultrasound
chemical dissolution
quantitative analysis
cotton
polyester
blended fabrics
ultradźwięki
rozpuszczanie chemiczne
analiza ilościowa
bawełna
poliester
tkanina
Opis:
In this paper, the feasibility of applying ultrasonic technology to quantitative analysis of cotton and polyester blended fabrics by the chemical dissolution method is explored. Four varieties of blends with different cotton contents were employed and dissolved in sulfuric acid solution with ultrasound assistance. Although three different frequencies: 20, 28 and 40 kHz were adopted, the experimental results indicate that there is no difference between them. For some fabrics that cannot be untwisted into yarns, ultrasonic technology has good experimental results while only needing a fabric form prepared from a small, long strip. By comparison with the traditional mechanical oscillation method stated in ISO 1833-11:2006, the more meaningful role of ultrasonic lies in the fact that the experimental time and usage of solvent can be reduced by half, which is in agreement with resource savings and environmental protection. Broadly speaking, the study demonstrated that ultrasound assisted chemical dissolution for the quantitative analysis of cotton and polyester blended fabric is feasible.
W pracy przedstawiono możliwości zastosowania technologii ultradźwiękowej do ilościowej analizy tkanin bawełnianych i poliestrowych metodą rozpuszczania chemicznego. Zastosowano cztery rodzaje mieszanek o różnej zawartości bawełny i rozpuszczono w roztworze kwasu siarkowego przy pomocy ultradźwięków. Mimo że przyjęto trzy różne częstotliwości: 20, 28 i 40 kHz, wyniki eksperymentalne wykazały, że nie ma między nimi różnic. W przypadku niektórych tkanin, które nie mogą być rozdzielone w tradycyjny sposób, technologia ultradźwiękowa ma dobre wyniki eksperymentalne. W porównaniu z tradycyjną metodą, określoną w normie ISO 1833-11: 2006, metoda z zastosowaniem ultradźwięków pozwala na skrócenie czasu procesu i zmniejszenie zużycia rozpuszczalnika o połowę, co jest istotne z punktu widzenia oszczędności zasobów i ochrony środowiska. W badaniu wykazano,że możliwe jest wykorzystanie ultradźwięków wspomaganych rozpuszczaniem chemicznym w celu ilościowej analizy tkanin bawełnianych i poliestrowych.
Źródło:
Fibres & Textiles in Eastern Europe; 2017, 5 (125); 47-51
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies