Mining equipment diagnostics in a mineshaft dewatering system – case study
Diagnostyka urządzeń górniczych w systemie odwodnienia szybu kopalni - studium przypadku
Autorzy:
Rogowski, Rafał
Werbińska-Wojciechowska, Sylwia
Powiązania:
https://bibliotekanauki.pl/articles/38938384.pdf
Data publikacji:
2023
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
maintenance
mining industry
pump maintenance
diagnostics
mine shaft
dewatering system
utrzymanie ruchu
przemysł górniczy
utrzymanie pomp
diagnostyka
system odwodnienia
szyb kopalni
Opis:
Maintenance issues in mines are particularly important due to the type and complexity of equipment in operation or working in hostile (even extreme) conditions. In this context, the need to ensure continuous/regular maintenance of machinery, identify potential hazards and ensure operational safety seems to be a challenge. Moreover, selecting an appropriate maintenance method is crucial for a mine, both economically and in technical/organizational terms. This study aims to present the preliminary results of diagnostic tests for pumps performing operational tasks in a mine shaft dewatering system. In addition, this study focused on a detailed discussion of the basic elements of the mine shaft dewatering system and the technical objects studied. A preliminary operational test plan for the investigated pumps operating in the mine shaft dewatering system is also presented. This enabled a discussion of the results obtained from the tests of the first quarter of 2023. The tests used three basic diagnostic methods: vibration analysis, thermal imaging and acoustic testing. Potential directions for further research in the analyzed area were also indicated.
Problematyka utrzymania ruchu w kopalniach jest szczególnie istotna ze względu na typ i złożoność eksploatowanych urządzeń czy pracę w nieprzyjaznych (wręcz ekstremalnych) warunkach operacyjnych. Wyzwaniem w tym kontekście jest konieczność zapewnienia ciągłych/regularnych napraw maszyn, identyfikacji potencjalnych zagrożeń oraz zapewnienia bezpieczeństwa pracy. W tym kontekście, dobór odpowiedniej metody utrzymania ruchu ma kluczowe znaczenie dla kopalni, zarówno w kontekście ekonomicznym jak i techniczno-organizacyjnym. Celem pracy jest więc przedstawienie wstępnych wyników badań diagnostycznych przeprowadzonych dla pomp realizujących zadania operacyjne w systemie odwodnienia szybu kopalni. W ramach realizacji celu pracy skupiono się na szczegółowym omówieniu podstawowych elementów systemu odwodnienia szybu kopalni oraz badanych obiektów technicznych. Przedstawiono również wstępny plan badań eksploatacyjnych dla badanych pomp, funkcjonujących w systemie odwodnienia szybu kopalni. Pozwoliło to na omówienie uzyskanych wyników badań, przeprowadzonych w pierwszym kwartale 2023 roku. Badania zostały opracowane z wykorzystaniem trzech podstawowych metod diagnostycznych: analizy drgań, termowizji oraz badań akustycznych. Wskazano również potencjalne kierunki dalszych prac badawczych w analizowanym obszarze.
Źródło:
Journal of KONBiN; 2023, 53, 3; 69-86
1895-8281
2083-4608
Pojawia się w:
Journal of KONBiN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimisation of reliability and maintenance plan of the high-pressure fuel pump system on marine engine
Autorzy:
Knežević, Vlatko
Stazić, Ladislav
Orović, Josip
Pavin, Zoran
Powiązania:
https://bibliotekanauki.pl/articles/32898209.pdf
Data publikacji:
2022
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
reliability
maintenance modification
high-pressure fuel pump
risk analysis
Opis:
This paper presents a method of adjusting and designing the maintenance scheme for the high-pressure fuel pumps of a slow-speed two-stroke marine engine, MAN 6S70MC-C. The maintenance database for the marine fuel system was obtained from the planned maintenance software, and covered a period of 11 years. During this period, 29 failures occurred that required corrective actions. Our methodology includes failure mode analysis, risk analysis, reliability calculation and maintenance interval adjustment. Each failure is described using a failure mode analysis, based on a combination of the mode and cause of failure. The objective of this study is to recommend a new preventive maintenance interval based on the exponential reliability results and the analysed maintenance data. The initial maintenance plan for each fuel pump was set to 8,000 running hours, whereas in the modified plan, it is recommended to set this to 4,000 hours. Our results show an increase in the system reliability from 60% to 95% when the new modified maintenance plan is applied. In addition, the results and the recommended initial maintenance schedule are validated based on three similar types of engine with the same fuel pump system. The new maintenance approach can reduce the risk of component failure, which will lead to increased reliability of the fuel pump system and the optimisation of maintenance costs.
Źródło:
Polish Maritime Research; 2022, 4; 97-104
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Quasi-periodic Inspection and Preventive Maintenance Policy Optimisation for a system with Wiener Process degradation
Autorzy:
Gao, Wenke
Wang, Yu
Zhang, Xiwen
Wang, Zhuangzhuang
Powiązania:
https://bibliotekanauki.pl/articles/24200831.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
preventive maintenance
Wiener process
quasi-periodic inspection policy
axial piston pump
Opis:
Periodic inspection policy is performed for some degradation systems to check their degradation states, whereas it is usually difficult to implement on time due to impact of some random factors. Inspections and some maintenance actions are implemented in an inspection window with random, and thus how to optimize the inspection windows and the degradation threshold of the system to perform preventive maintenance (PM) are beneficial in practice. To this end, an optimisation of quasi-periodic inspection and PM policy with inspection window is proposed for a degradation system whose degradation followed Wiener process with a linear drift. Assume that PM can change the degradation rate and inspections are randomly performed in each inspection window. After optimisation, the optimal interval of the inspection window, the degradation threshold of PM and PM policy are determined by minimising the long-term running cost rate of the system. Finally, modeling and optimisation are illustrated using the degradation process of an axial piston pump, and the sensitivity analysis of some key parameters is conducted.
Źródło:
Eksploatacja i Niezawodność; 2023, 25, 2; art. no. 162433
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies