Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "pulse radiolysis" wg kryterium: Temat


Wyświetlanie 1-6 z 6
Tytuł:
The mechanism and kinetics of ozone formation in a pulse radiolysis study of the Ar-O2 system
Autorzy:
Wojciechowski, K.
Sugier, D.
Wnorowski, K.
Kowalczyk, J.
Jówko, A.
Powiązania:
https://bibliotekanauki.pl/articles/147852.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
pulse radiolysis
argon
oxygen
ozone
Opis:
The mechanism and kinetics of O3 formation after an electron pulse have been studied in the Ar-O2 systems by time resolved optical measurements at gamma = 260 nm. The second order rate constant of energy transfer from excited Ar(4s,4p) states to O2 molecules: (1) Ar*,Ar** + O2 → O2* + Ar, was found to be (8.9 ± 2.1) x 10-10 cm3 s-1. It was found also the evidence of the third order process contribution to the energy transfer: (2) Ar*,Ar** + Ar + O2 → products, with the rate constant in the range (1.5-3.7) x 10-29 cm6 s-1. The rate constant of the deactivation of excited ozone molecules by O2 was found to be (5.1 ± 0.6) ´ 10-15 cm3 s-1.
Źródło:
Nukleonika; 2005, 50,suppl.2; 29-33
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Formation of Br2 '-, BrSCN'- and (SCN)2'-intermediates in the ionic liquid methyltributylammonium bis[(trifluoromethyl)sulfonyl]imide. Pulse radiolysis study
Autorzy:
Grodkowski, J.
Nyga, M.
Mirkowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/147848.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
ionic liquids
pulse radiolysis
Br2
Opis:
The reactions of Br2 '- anion radicals with thiocyanate anions in the ionic liquid methyltributylammonium bis[(trifluoromethyl)sulfonyl]imide (R4NNTf2) were studied by pulse radiolysis. Reaction of solvated electrons with BrCH2CH2Br (DBE), k = (1 2)×108 L.mol 1.s 1, leads to the production of Br2'- anion radicals. The intermediate absorption spectra following pulse radiolysis of DBE/SCN-/Br-/ solutions in R4NNTf2 correspond to Br2 '-, BrSCNo- and (SCN)2'- anion radicals. The participation of these radicals in the spectra changes with progressing reactions and depends on the concentration Br- and SCN- in the solution.
Źródło:
Nukleonika; 2005, 50,suppl.2; 35-38
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Free radicals in chemistry, biology and medicine: contribution of radiation chemistry
Autorzy:
Bobrowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/147946.pdf
Data publikacji:
2005
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
free radicals
pulse radiolysis
oxidative stress
ionic liquids
long range electron transfer
beta-amyloid peptide
Opis:
The scope of this article is limited to the concept of free radical and its historical background and a brief introduction to time-resolved techniques (pulse radiolysis, laser flash photolysis), which allowed direct observation of free radicals on real time. The selected contributions of pulse radiolysis to better understanding the role of free radical reactions in chemistry, biology and medicine are presented and some selected future research needs and opportunities in radiation chemistry are briefly addressed.
Źródło:
Nukleonika; 2005, 50,suppl.3; 67-76
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Intermediates derived from p-terphenyl in the methyltributylammonium bis[(trifluoromethyl)sulfonyl]imide ionic liquid saturated with carbon dioxide : pulse radiolysis study
Autorzy:
Kocia, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/2173388.pdf
Data publikacji:
2022
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
carbon dioxide
ionic liquid
methyltributylammonium bis[(trifl uoromethyl)sulfonyl]imide
p-Terphenyl
pulse radiolysis
radical ions
Opis:
Radiation-induced processes in ionic liquid (IL) methyltributylammonium bis[(trifl uoromethyl)sulfonyl] imide ([MeBu3N][NTf2]) solutions containing p-terphenyl (TP) and saturated with carbon dioxide (CO2) were studied using nanosecond pulse radiolysis technique with UV-vis detection. The transient absorption spectra generated in these solutions were assigned to TP radical anions (TP•–) and triplet excited states (3TP*). Saturation of [MeBu3N][NTf2] solutions with carbon dioxide efficiently takes out presolvated electrons (e–presolv) and solvated electrons (e–solv). On the other hand CO2 is not a scavenger of excited states of TP (1TP*, 3TP*), which in the reaction with triethylamine (TEA) leads to the formation of TP•-.
Źródło:
Nukleonika; 2022, 67, 4; 73--80
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recent upgrading of the nanosecond pulse radiolysis setup and construction of laser flash photolysis setup at the Institute of Nuclear Chemistry and Technology in Warsaw, Poland
Autorzy:
Szreder, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173384.pdf
Data publikacji:
2022
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
computer-controlled systems
data collection software
data processing software
laser flash photolysis
pulse radiolysis
time-resolved techniques
Opis:
Modification of pulse radiolysis (PR) setup and construction of a new laser flash photolysis (LFP) setup at the Institute of Nuclear Chemistry and Technology (INCT) is described. Both techniques are dedicated to studying fast reactions in real time by direct observation of transients. Time resolution of the PR setup at INCT was ~11 ns, limited by the duration of the electron pulse. Implementation of a new spectrophotometric detection system resulted in a significant broadening of experimental spectral range with respect to the previous setup. Noticeable reduction of the noise-to-signal ratio was also achieved. The LFP system was built from scratch. Its time resolution was ~6 ns, limited by the duration of a laser pulse. LFP and PR were purposely designed to share the same hardware and software solutions. Therefore, components of the detection systems can be transferred between both setups, signifi cantly lowering the costs and shortening the construction/upgrading time. Opened architecture and improved experimental fl exibility of both techniques were accomplished by implementation of Ethernet transmission control protocol/Internet protocol (TCP/IP) communication core and newly designed software. This is one of the most important enhancements. As a result, new experimental modes are available for both techniques, improving the quality and reducing the time of data collections. In addition, both systems are characterized by relatively high redundancy. Currently, implementation of new equipment into the systems hardly ever requires programming. In contrast to the previous setup, daily adaptations of hardware to experimental requirements are possible and relatively easy to perform.
Źródło:
Nukleonika; 2022, 67, 3; 49--64
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie metod analitycznych w wykrywaniu napromieniowania żywności. : przegląd najnowszych metod w świetle regulacji unijnych : radioliza pulsowa, spektroskopia w podczerwieni i ramanowska w analizie napromieniowanej żywności
Application of analytical methods for detecting food irradiation : an overview of recent methods in regard of EU regulations
Autorzy:
Lewandowska, H.
Jakubczak, A.
Świsłocka, R.
Stachelska, M. A.
Lewandowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/271340.pdf
Data publikacji:
2012
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
sterylizacja radiacyjna
żywność
spektroskopia w podczerwieni
spektroskopia ramanowska
radioliza impulsowa
radiation sterilization
food
infrared spectroscopy
Raman spectroscopy
pulse radiolysis
Opis:
Napromienianie żywności jest metodą konserwacji o niemal stuletniej tradycji. Pomimo, że zostało zaakceptowane przez organy kontroli jakości w wielu krajach na całym świecie, nadal budzi kontrowersje. Nie ulega kwestii, że procesy napromieniania żywności powinny być monitorowane, a żywność sterylizowana radiacyjnie powinna podlegać bardzo ścisłej kontroli jakości. Z tej przyczyny poszukuje się nowych metod wykrywania i dozymetrii napromieniowanej żywności. Obecnie wśród metod analitycznych wykrywania żywności poddanej napromieniowaniu, znormalizowanych przez Europejski Komitet Normalizacyjny (CEN), są tylko dwie metody spektroskopowe: rezonans paramagnetyczny i luminescencja stymulowana światłem, jednak badania wskazują na możliwość zastosowania wielu innych dogodnych rozwiązań z zastosowaniem m.in. spektroskopii Ramana i widm w bliskiej podczerwieni. Spektroskopowe metody oceny napromieniowanej żywności dają możliwość szybkiego i precyzyjnego wykrycia zastosowanych dawek, dlatego zasługują na zainteresowanie ze strony zespołów badawczych i wdrożeniowych. Niniejszy przegląd omawia krótko obecny stan naukowy i prawny monitoringu napromieniowania artykułów żywnościowych w Polsce i na świecie, a następnie prezentuje najnowsze doniesienia i osiągnięcia w zakresie zastosowania metod spektroskopowych w ocenie napromienionej żywności.
Food irradiation as a method of preservation is nearly a century old. Although it has been approved by the quality control in many countries around the world, it still remains a matter of controversy. There is no question that the process of food irradiation should be monitored, and irradiated foods should be subject to very strict quality control. For this reason the search for new methods of detection and dosimetry of irradiated foods is required. Currently, among the analytical methods for detecting irradiated foods standardized by the European Committee for Standardization (CEN) only two are the spectroscopic methods: EPR and photostimulated luminescence, but studies indicate the possibility of using a number of other convenient solutions, among others Raman and near-infrared spectra. Spectroscopic methods for assessing irradiated foods make it possible to quickly and accurately detect the applied dose, and shall draw attention of the research and implementation teams. This review briefly discusses the current scientific and legal status of irradiated food monitoring in Poland and worldwide and presents the latest achievements in the application of spectroscopic methods in the evaluation of food irradiation.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2012, 17, 4; 79-85
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies