Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "przetwornik" wg kryterium: Temat


Tytuł:
Facilitating optimal operations of a wave Energy converter using a preeminent mooring line: an entropy weight-VIKOR method
Autorzy:
Nwaoha, Thaddeus C.
Udosoh, Nsisong E.
Powiązania:
https://bibliotekanauki.pl/articles/2106432.pdf
Data publikacji:
2022
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
mooring line
alternatives
criteria
wave energy converter
entropy weight
VIKOR
liny cumownicze
rozwiązania alternatywne
kryteria
energia fal
przetwornik energii
entropia wagi
Opis:
This study employed viable methods for the selection of a preeminent mooring line amongst other alternatives for the mooring of a floating wave energy converter (WEC) in shallow waters. Conventional mooring lines for WEC mooring are identified for an optimal selection exercise. A combination of the Entropy Weight and Visekriterijumska Optimizacijia I Kompromisno Resenje (VIKOR) methods is utilized in the aforementioned exercise. The two methods are effectively used in an assessment of the attributes and performance of various mooring lines in practical application. The result obtained demonstrated that a steel wire rope is the best mooring line suitable for WEC system operations. It constitutes a good reference to marine and offshore engineering industries in decision making related to optimal mooring lines suitable for the mooring of a WEC system in shallow waters.
Źródło:
Journal of Mechanical and Energy Engineering; 2022, 6, 1; 77--84
2544-0780
2544-1671
Pojawia się w:
Journal of Mechanical and Energy Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frequency-to-code converter with direct data transmission
Przetwornik częstotliwość-kod z bezpośrednią transmisją danych
Autorzy:
Warda, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2174748.pdf
Data publikacji:
2022
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
frequency
digital period measurement
frequency-to-code converter
microcontroller
częstotliwość
cyfrowy pomiar okresu
przetwornik częstotliwości na kod
mikrokontroler
Opis:
Signal frequency is one of the most popular information carriers in measurement technology. A circuit called a frequency-to-code converter is used to convert frequency into numerical values. Frequency-to-code converters usually operate in the mode of a recorder of a certain number of periods of the signal under test. Often it is a microcontroller-based circuit that uses built-in memory to collect measurement data. The size of the memory limits the measurement capabilities of the transmitter. The paper presents the development of a frequency-to-code converter that sends measurement data directly to the host computer without collecting the results in the RAM of the converter. The working algorithm of the transmitter is presented. The results of measurement experiments carried out for sample signals of constant and variable frequency are presented.. The metrological analysis of the results is presented.
Częstotliwość sygnału jest w technice pomiarowej jednym z popularniejszych nośników informacji. Do konwersji częstotliwości w wartości liczbowe używa się układu zwanego przetwornikiem częstotliwość-kod. Przetworniki częstotliwość-kod zwykle pracują w trybie rejestratora określonej liczby okresów badanego sygnału. Często jest to układ oparty o mikrokontroler wykorzystujący wbudowaną pamięć do gromadzenia danych pomiarowych. Rozmiar pamięci ogranicza możliwości pomiarowe przetwornika. W artykule zaprezentowano opracowanie przetwornika częstotliwość-kod przesyłającego bezpośrednio dane pomiarowe do komputera nadrzędnego bez gromadzenia wyników w pamięci RAM przetwornika. Zaprezentowano algorytm pracy przetwornika. Przedstawiono wyniki przeprowadzonych eksperymentów pomiarowych dla przykładowych przebiegów o stałej i zmiennej częstotliwości. Przedstawiono analizę metrologiczną wyników.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2022, 12, 4; 74--77
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gas temperature meter
Autorzy:
Zashchepkina, N. M.
Svyta, M. P.
Powiązania:
https://bibliotekanauki.pl/articles/2105505.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
meter
temperature
PT100
thermal converter
sensor
probe
miernik
temperatura
przetwornik termiczny
czujnik
sonda
Opis:
Purpose: of the article is to develop a digital portable gas temperature meter in the range of -50…+600°C. To measure the temperature of dusty gas flows in the air pollution sources with the least significant digit of the digital device 1°C. Design/methodology/approach: The microprocessor measuring unit, probe and software is proposed. It leads to build a high-precision temperature meter based on a thin film sensor HM220 type "pt100". Findings: The calculation of the electrical schematic diagram parameters for signal conditioning of the sensor relative to the input range of the analog-to-digital converter. The experimental measuring unit and the probe of the gas temperature meter are assembled. The principle of the gas temperature meter calibration with the help of a precision resistance box MSR-60M is considered. The experimental gas temperature meter has a total standard uncertainty determined by type B for a maximum value of the measurement range of 1.94°C. The error of the sensor "pt100" makes the largest contribution to the total standard uncertainty, so the error increases in proportion to the value of the measured temperature. Research limitations/implications: On the basis of the proposed design of gas temperature meter it is possible to construct devices with various lengths of probes. Practical implications: The proposed meter is designed for environmental laboratories that measure the velocity, flow and sampling of dust and gas emissions from sources of air pollution. Originality/value: The device design differs due to the use of thermostable wire made of constantan as extending conductors of the temperature sensor, which is included in the unbalanced Wheatstone bridge. This solution allows the use of unipolar power supply 3.3 V for both analog and digital part of the meter. Temperature meter based on a thin film resistance thermometer is characterized by relative ease of manufacture, low material consumption, cost and high reliability.
Źródło:
Journal of Achievements in Materials and Manufacturing Engineering; 2022, 111, 1; 33--41
1734-8412
Pojawia się w:
Journal of Achievements in Materials and Manufacturing Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultradźwięki w zastosowaniach medycznych – nowe możliwości pomiarowe Zakładu Mechaniki i Akustyki
Medical ultrasounds – new metrological capabilities of Mechanics and Acoustics Department
Autorzy:
Dobrowolska, Danuta
Falińska, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/2200084.pdf
Data publikacji:
2022
Wydawca:
Główny Urząd Miar
Tematy:
moc ultradźwiękowa
waga siły promieniowania
onduktancja promieniowania
przetwornik ultradźwiękowy
hydrofon
ultrasound power
radiation force balance
radiation conductance
ultrasound transducer
hydrophone
Opis:
Artykuł przedstawia aparaturę pomiarową do wzorcowań i badań w dziedzinie ultradźwięków w zastosowaniach medycznych, zakupioną dla Głównego Urzędu Miar w 2021 roku i jej możliwości pod kątem zapewnienia w Polsce spójności pomiarowej w tej dziedzinie. Przedstawia też stan badań nad wdrożeniem w GUM metod realizowanych za pomocą zakupionych systemów pomiarowych oraz wskazuje perspektywy rozwoju.
The article presents measuring equipment for calibration and testing in the field of medical ultrasound, purchased for the Central Office of Measures in 2021, and its capabilities in terms of assuring measurement traceability in this area in Poland. It also presents the state of research on the implementation of the methods implemented in the GUM with the use of purchased measurement systems and indicates development prospects.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2022, 1 (28); 37--42
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultradźwiękowa technika haptyczna - działanie, zastosowania, zagrożenia
Ultrasonic haptic technique - operation, applications, hazards
Autorzy:
Morzyński, Leszek
Swidziński, Adam
Shmyk, Aliaksandra
Powiązania:
https://bibliotekanauki.pl/articles/31342466.pdf
Data publikacji:
2022
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ultradźwiękowa technika haptyczna
przetwornik haptyczny
hałas ultradźwiękowy
ultrasonic haptic technique
haptic device
ultrasonic noise
Opis:
Ultradźwiękowa technika haptyczna to nowa, wchodząca właśnie na rynek komercyjny technika, umożliwiająca tworzenie w powietrzu nad przetwornikiem haptycznym niewidocznych obiektów, które mogą być wyczuwane za pomocą zmysłu dotyku. W technice tej skoncentrowana i odpowiednio modulowana wiązka ultradźwięków wzbudza drgania skóry człowieka, pobudzając w ten sposób znajdujące się w niej mechanoreceptory i wywołując uczucie dotyku. Technika ta ma wiele potencjalnych zastosowań – od wzbogacania rzeczywistości wirtualnej, przez interfejsy sterujące, do pomocy dla osób niepełnosprawnych wzrokowo. Z drugiej jednak strony, ze względu na zastosowanie ultradźwięków o wysokich poziomach ciśnienia akustycznego, ta technika może się stać źródłem zagrożeń dla użytkownika. W artykule omówiono zasadę działania ultradźwiękowej techniki haptycznej, jej możliwe zastosowania oraz dostępne na rynku komercyjnym ultradźwiękowe przetworniki haptyczne. Przedstawiono również wyniki wstępnej oceny zagrożenia hałasem ultradźwiękowym podczas korzystania z ultradźwiękowej techniki haptycznej, oparte na badaniach hałasu ultradźwiękowego, przeprowadzonych w odniesieniu do jednego z omówionych przetworników.
The ultrasonic haptic technique is a new, commercially available technique that allows the creation of invisible objects in the air above the haptic device, which can be sensed by the sense of touch. In this technique, a concentrated and appropriately modulated ultrasound beam causes vibrations of the human skin, thus stimulating the mechanoreceptors located in it and causing a feeling of touch. The technique has many potential applications, ranging from enriching virtual reality through control interfaces to aids for people with visual disabilities. On the other hand, this technique, due to the use of ultrasound with high sound pressure levels, may become a source of potential hazards to its user. The article discusses the principle of operation of the ultrasonic haptic technique, its possible applications and currently commercially available ultrasonic haptic devices. The paper also presents the results of a preliminary assessment of ultrasonic noise hazard caused by the ultrasonic haptic technique based on the ultrasonic noise measurements carried out for one of the described devices.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2022, 6; 18-22
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel two-phase interleaved parallel bi-directional DC/DC converter
Autorzy:
Zhang, Baoge
Hong, Deyu
Wang, Tianpeng
Zhang, Zhen
Wang, Donghao
Powiązania:
https://bibliotekanauki.pl/articles/1841340.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
bi-directional DC/DC converter
energy storage system
interleaved parallel structure
voltage stress
Z-source network
dwukierunkowy przetwornik DC/DC
system magazynowania energii
przeplatana struktura równoległa
stres napięciowy
Sieć źródłowa Z
Opis:
The energy storage system (ESS) is an important way to improve the power quality of renewable energy sources (such as solar energy and wind energy). A bi-directional DC/DC converter is an essential part of the ESS to achieve bi-directional energy transfer. According to the characteristics of the low-voltage gain and high-voltage stress of switches in the existing bi-directional DC/DC converter, this study proposes a novel two-phase interleaved parallel bi-directional DC/DC converter. The converter can effectively combine the advantages of a Z-source network and interleaved parallel structure. The working principle, the boost mode and buck mode of the converter are analyzed in detail. In addition, the voltage conversion ratios under the two modes are deduced. The control strategy of the two-phase interleaved parallel bi-directional DC/DC converter is introduced in detail. Furthermore, the main working waveforms of the system under each working mode are verified by building a simulation experiment model using MATLAB/Simulink. The simulation results show that the system has advantages of high-voltage gain, low-voltage stress of switches and automatic current sharing between inductors.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 219-231
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving the accuracy of vibration measurement results
Poprawa dokładności wyników pomiarów drgań
Autorzy:
Stakhova, Anzhelika
Kvasnikov, Volodymyr
Powiązania:
https://bibliotekanauki.pl/articles/2033291.pdf
Data publikacji:
2021
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
vibrations
measuring transducer
vibroacoustic parameter
vibration measurement
drgania
przetwornik pomiarowy
parametr wibroakustyczny
pomiar drgań
Opis:
The current state of control of vibration measuring equipment is studied in the work, the analysis of technologies of control of vibrating measuring machine equipment is carried out. It is determined that during the control a sufficient requirement for the analysis of changes in the state over time is to conduct periodic vibration measurements in the same modes of operation of the object. Therefore, the urgent task is to increase the reliability and accuracy of measurement results. It can be enhanced by obtaining additional information. For this purpose, recommendations for optimizing the vibration control points of the mechanism are formed. To increase the accuracy of measurement results when controlling the equipment for vibration signals, the methods of mounting the measuring transducer in the equipment monitoring system are considered. It is shown that the method of mounting the measuring transducer can affect the results of vibration measurements.
W pracy badany jest aktualny stan sterowania wibracyjnymi urządzeniami pomiarowymi, prowadzona jest analiza technologii sterowania wibracyjnymi urządzeniami pomiarowymi. Stwierdzono, że podczas kontroli wystarczającym wymogiem do analizy zmian stanu w czasie jest prowadzenie okresowych pomiarów drgań w tych samych trybach pracy obiektu. Dlatego pilnym zadaniem jest zwiększenie wiarygodności i dokładności wyników pomiarów. Można go ulepszyć poprzez uzyskanie dodatkowych informacji. W tym celu formułowane są zalecenia dotyczące optymalizacji punktów kontroli drgań mechanizmu. Aby zwiększyć dokładność wyników pomiarów przy sterowaniu aparaturą na sygnały wibracyjne, rozważono sposoby montażu przetwornika pomiarowego w systemie monitorowania aparatury. Wykazano, że sposób mocowania przetwornika pomiarowego może wpływać na wyniki pomiarów drgań.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2021, 11, 3; 14-17
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Integrated analytical-field design method of multi-disc magnetorheological clutches for automotive applications
Autorzy:
Kluszczyński, Krzysztof
Pilch, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/2086881.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electromechanical convertor
drive system component
electromagnetic calculations
MR fluids
magnetorheological fluids
MR multi-disc clutch
multi-disc magnetorheological clutch
clutch design
analytical field
design
przetwornik elektromechaniczny
element układu napędowego
obliczenia elektromagnetyczne
płyny MR
płyny magnetoreologiczne
wielotarczowe sprzęło magnetoreologiczne
sprzęgło wielotarczowe
projektowanie
Opis:
This study proposes a new integrated analytical-field design method for multi-disc magnetorheological (MR) clutches. This method includes two stages, an analytical stage (composed of 36 algebraic formulas) and a field stage based on the finite element method (FEM). The design procedure is presented systematically, step-by-step, and the results of the consecutive steps of the design calculations are depicted graphically against the background of the entire considered clutch. The essential advantage of the integrated method with this two-stage structure is the relatively high accuracy of the first analytical stage of the design procedure and the rapid convergence of the second field stage employing the FEM. The essence of the new method is the introduction of a yoke factor ky (the concept of which is based on the theory of induction machines) that determines the ratio of magnetomotive force required to magnetise the entire magnetic circuit of the clutch to the magnetomotive force required to magnetise the movement region. The final value, the yoke factor ky is determined using loop calculations. The simplicity of the developed design method predisposes its use in optimisation calculations. The proposed method can also be adapted to other MR devices analysed in shear mode.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 6; e139392, 1--15
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Budowa i zasada działania resolwera reluktancyjnego
Construction and principles of operation of variable-reluctance resolver
Autorzy:
Bałkowiec, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/2056364.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
przetwornik położenia kątowego
resolwer reluktancyjny
angular position transducer
Variable-Reluctance resolver
Opis:
Resolwer reluktancyjny jest przetwornikiem położenia kątowego działającym na zasadzie transformatora położenia kątowego. Przetworniki tego typu cechują się odpornością na wysokie temperatury, wstrząsy, wilgotność i zapylenie, dzięki czemu są wykorzystywane w układach napędowych o regulowanej prędkości obrotowej np. w samochodach elektrycznych. W artykule przedstawiono podstawowe informacje o budowie i zasadzie działania resolwera reluktancyjnego.
Variable-Reluctance resolver is a rotor angular position transducer, which works on principles of rotary electric transformer. This type of transducers are resistant to high temperatures, shocks, humidity and dust and that is why they are used in propulsion drives with speed regulation e.g. electric vehicles. Article presents basic information about construction and principles of operation of Variable-Reluctance resolver.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2019, 3-4, 123-124; 65--68
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microfabricated 2D planar eddy-current microcoils for the non-destructive testing of grinding burn marks
Mikrofabrykowane płaskie wiroprądowe mikrocewki 2D do nieniszczących badań błędów szlifierskich
Autorzy:
Khazi, Isman
Kovacs, Andras
Kumar, Vaibhav
Dhumal, Pranav
Mescheder, Ulrich
Powiązania:
https://bibliotekanauki.pl/articles/107862.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
cewki płaskie 2D
szlifowanie śladów przegrzań
badania nieniszczące (NDT)
mikro przetwornik wiroprądowy
2D planar coils
grinding burn marks
non-destructive testing (NDT)
micro eddy-current sensor
Opis:
Microtechnology based 2D planar eddy-current microcoils (μCoils) are simulated and fabricated for the detection of grinding burn marks in conductive materials such as industrial hard steels, which are predomi-nantly used for manufacturing of structured parts using grinding. COMSOL multiphysics simulation tool is used to simulate μCoils with various geometries, namely: circular spiral, circular non-spiral and meander type geometry, to investigate the influence of the frequency on the resultant impedance of the μCoil as a function of the grinding burn marks. The simulation results show that the impedance of the μCoil of all geometries varies in response to a 1500 μm wide grinding burn mark. The sensitivity of the μCoil to detect even grinding burn marks with 200 μm width is improved by modifying the wire width of the non-spiral μCoils. Furthermore, as a proof of concept non-spiral μCoils with varying number of turns (5,10 and 20) were fabricated using ferromagnetic nickel-cobalt alloys. The experimental results show that the impedance of the fabricated μCoils varies as a function of the grinding burn mark present on a 42CrMo4 workpiece.
Płaskie wiroprądowe mikrocewki 2D (μCoils) oparte na mikrotechnologii przebadano numerycznie a następnie wytwarzano w celu wykrywania śladów lokalnego przegrzania w materiałach przewodzących, takich jak przemysłowe stale twarde, które są głównie wykorzystywane do produkcji elementów konstrukcyjnych przy użyciu technologii szlifierskich. Oprogramowanie do numerycznych obliczeń wielofizycznych COMSOL zostało użyte do symulacji mikrocewek μCoil o różnych geometriach w celu zbadania wpływu częstotliwości na wynikową impedancję μCoil w funkcji szlifowania śladów przegrzania. Wyniki symulacji pokazują, że impedancja μCoil we wszystkich geometriach zmienia się pod wpływem śladu po szlifowaniu o szerokości 1500 μm. Wrażliwość μCoil na wykrywanie śladów przegrzania nawet o szerokości 200 μm jest poprawiona poprzez modyfikację szerokości drutu nie spiralnych mikrocewek. Ponadto, jako dowód słuszności koncepcji, wykonano niespiralne cewki o zmiennej liczbie zwojów (5,10 i 20) przy użyciu ferromagnetycznych stopów nikiel-kobalt. Wyniki eksperymentów pokazują, że impedancja wytworzonych mikrocewek zmienia się w zależności od śladu po szlifowaniu obecnego na elemencie wykonanym z 42CrMo4.
Źródło:
Badania Nieniszczące i Diagnostyka; 2019, 3; 29-35
2451-4462
2543-7755
Pojawia się w:
Badania Nieniszczące i Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitorowanie obciążeń w obudowie łukowej z zastosowaniem przetworników strunowych
Autorzy:
Woszczyński, Mariusz
Tokarczyk, Jarosław
Mazurek, Krzysztof
Pytlik, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/111300.pdf
Data publikacji:
2019
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
przetwornik z drgającą struną
pomiar odkształceń
geometria obudowy łukowej
badania
analiza MES
Opis:
W artykule zaprezentowano koncepcję pomiaru obciążenia i geometrii obudowy wyro-biska korytarzowego z zastosowaniem przetworników z drgającą struną oraz przetworników linkowych. W ramach realizacji projektu europejskiego INESI przeprowadzono badania laboratoryjne, a następnie badania stanowiskowe kompletnych odrzwi obudowy łukowej pod obciążeniem. Wyniki odkształcenia uzyskane z przetworników strunowych są porównywalne z wynikami uzyskanymi z tensometrów. Zaprezentowano również obliczenia wytrzymałościowe MES, które wykazały dużą zgodność z wynikami badań stanowiskowych.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2019, 57, 1; 59-69
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tool control the concentration of carbon dioxide in the flue gas boilers based on the optical absorption method
Narzędzie kontroli stężenia dwutlenku węgla w spalinach kotłów pracujące na podstawie metody absorpcji optycznej
Autorzy:
Vasilevskyi, Oleksandr
Dudatiev, Ihor
Ovchynnykov, Kostyantyn
Powiązania:
https://bibliotekanauki.pl/articles/408298.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
vehicle control
optical measuring transducer
concentration of carbon dioxide absorption spectrum
uncertainty of measurement
reliability of control
sterowanie pojazdem
optyczny przetwornik pomiarowy
stężenie widma absorpcji dwutlenku węgla
niepewność pomiaru
niezawodność sterowania
Opis:
The methodology for controlling the concentration of carbon dioxide in flue gases from boilers is an optical absorption method with improved metrological characteristics. Studies done in the article, provided the new, scientifically-based theoretical and practical results that are essential for improving the accuracy at the required speed process, control the carbon dioxide concentration in dual gas boilers based on the optical absorption method with compensation effect on the factors optical converter.
Metodologia kontroli stężenia dwutlenku węgla w spalinach kotłów wykorzystuje zjawisko absorpcji optycznej przy ulepszonych charakterystykach metrologicznych. Zaprezentowane w artykule badania dostarczyły nowych wyników, opartych na podstawach naukowych i praktycznych, które są niezbędne do poprawy dokładności przy wymaganej szybkości przebiegu procesu kontroli stężenia dwutlenku węgla w podwójnych kotłach gazowych odbywającej się na podstawie metody absorpcji optycznej z kompensacją czynników w przetworniku optycznym.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2019, 9, 3; 30-34
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania diagnostyczne metali i stopów metodą PEC
Pulsed eddy current testing of metal and alloy
Autorzy:
Wrzuszczak, M.
Wrzuszczak, J.
Powiązania:
https://bibliotekanauki.pl/articles/267129.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
PEC
przetwornik wiroprądowy
impulsowy prąd wzbudzenia
analiza falkowa
pulsed Eddy current testing
wavelet analysis
Opis:
W publikacji przedstawiono wyniki badań metali nieferromagnetycznych z wykorzystaniem zjawiska prądów wirowych techniką PEC (Pulsed Eddy Current). Badania przeprowadzono na próbkach metali i stopów o znanej konduktywności w których wykonano wady wzorcowe w formie nacięć i nawiertów o znanych (zmierzonych) wymiarach geometrycznych. Zarejestrowane napięcia wyjściowe z przetwornika wiroprądowego poddano analizie metodą falkową z wykorzystaniem falek typu Morleta (morl) oraz symlet ósmego rzędu (sym8).
In this paper the results of pulsed eddy current testing (PEC) for nonferrous materials are presented. The research deals with metal and alloy probe (Al) with known value of conductivity with artificial defects in form discontinuities (notches) with known depth and width. The output signals from eddy current transducer for PEC technique picked up with a digital oscilloscope were recorded in separate files and then investigated by the set of analyzing wavelets. The programming environment of Matlab with the Wavelet Toolbox of The MathWorks was employed .The local properties of signals were derived applying Morlet wavelet (morl) and symlet of eighth order (sym8). Based on one-dimensional real signal in time the jointly frequency and time analysis was performed to extract the localization distinguishing details of meaning energy correlated with type and size of fabricated material flaws. Detecting the fundamental properties was performed with the scalogram plots. Some kind of causality was observed depending on localization the sound details the more right on the time axis the deeper or more extensive was the size of material flaw.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2018, 59; 215-218
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elektromagnetyczny nieliniowy przetwornik energii drgań mechanicznych ze sprężyną magnetyczną
Nonlinear electromagnetic energy harvester with a magnetic spring
Autorzy:
Kulik, M.
Gabor, R.
Powiązania:
https://bibliotekanauki.pl/articles/376064.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
elektromagnetyczne odzyskiwanie energii
przetwornik magnetyczny
nieliniowy rezonans
drgania
Opis:
W artykule zaprezentowano nieliniowy rezonansowy elektromagnetyczny przetwornik energii drgań mechanicznych w energię elektryczną, składający się z trzech magnesów trwałych: dwóch nieruchomych, zamocowanych do obudowy oraz jednego ruchomego, znajdującego się w jej wnętrzu. Konstrukcja obwodu magnetycznego układu umożliwia otrzymanie zawieszenia magnetycznego ruchomego magnesu wzdłuż osi jego ruchu. W pozostałych osiach jest on stabilizowany mechanicznie. Z kolei, sprężystość magnetyczna wytworzona przez ten układ magnesów, umożliwia powstanie nieliniowego rezonansu elektromechanicznego. W niniejszym artykule, stosując obliczenia polowe, zaprojektowano prototyp przetwornika pracujący w paśmie częstotliwości miedzy 20 i 25 Hz. Obliczone charakterystyki częstotliwościowe układu wykazały zbieżność z pomiarami.
In paper an electromagnetic energy harvester with two stationary permanent magnets fixed to casing and one movable PM inside is presented. The external force attached to the system causing displacements of the internal magnet, and thus the flux linkage changing in coil wounded on housing is received. In order to obtain the resonance frequency equal 25 Hz, the dimensions optimization was carried out. The results of measurements agree very well with the simulated frequency characteristics.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 95; 175-185
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental determination of lateral forces caused by bridge crane skewing during travelling
Eksperymentalne wyznaczanie sił poprzecznych wywołanych skrętem suwnicy podczas jazdy
Autorzy:
Zelić, A.
Zuber, N.
Šostakov, R.
Powiązania:
https://bibliotekanauki.pl/articles/302118.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
bridge crane skewing
lateral force transducer
load spectrum
fatigue
skręt suwnicy
przetwornik siły poprzecznej
widmo obciążenia
zmęczenie
Opis:
Crane condition depends on the large number of variables randomly changing in time. Due to the large number of parameters, skewing forces have stochastic character. Though in standards treated as occasional loads, their dynamic action in certain cases can cause fatigue damage of the crane travelling mechanisms, structure and runway components. Current European Norms have left the question of skewing forces influence upon the fatigue damage occurrence unresolved. The paper presents an experimental determination of lateral forces acting on the vertical wheels of a bridge crane using two different solutions of transducers for the direct measurement on the wheels of the cranes in operation, without changing the way of lateral guiding. As an illustration, few records of the measured wheel lateral force vs. time are shown. Presentation of such records in the form of a loading spectrum (e.g. using the software nCode), obtained during long-lasting or continuous monitoring of cranes in operation, is the first step in finding the relevant answer to the previously unresolved question.
Stan suwnicy pomostowej zależy od dużej liczby zmiennych losowo zmieniających się w czasie. Ze względu na dużą liczbę parametrów, siły skośne mają charakter stochastyczny. Chociaż w normach traktowane są one jako obciążenia sporadyczne, ich dynamiczne oddziaływanie w niektórych przypadkach może powodować zmęczeniowe uszkodzenie mechanizmu jazdy suwnicy, jak również jego konstrukcji oraz elementów toru jezdnego. Obecnie obowiązujące normy europejskie pozostawiają bez rozwiązania kwestię wpływu sił skośnych na występowanie uszkodzeń zmęczeniowych. W pracy przedstawiono metodę eksperymentalnego wyznaczania sił poprzecznych działających na koła pionowe suwnicy pomostowej. Metoda ta polega na użyciu dwóch różnych rozwiązań przetworników do bezpośredniego pomiaru sił na kołach pracującej suwnicy, bez zmiany sposobu prowadzenia bocznego . Dla ilustracji pokazano kilka zapisów pomiarów siły poprzecznej koła w funkcji czasu. Przedstawienie takich zapisów w postaci widma obciążenia (np. za pomocą oprogramowania nCode ), uzyskanego podczas długotrwałego lub ciągłego monitorowania suwnicy w trakcie jej eksploatacji, stanowi pierwszy krok do znalezienia rozwiązania nierozwikłanego do tej pory problemu.
Źródło:
Eksploatacja i Niezawodność; 2018, 20, 1; 90-99
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies