Wyszukujesz frazę "przekładnik" wg kryterium: Temat


Tytuł:
A comparison of the metrological properties of two-core current transformers
Porównanie właściwości metrologicznych dwurdzeniowych przekładników prądowych
Autorzy:
Dusza, D.
Powiązania:
https://bibliotekanauki.pl/articles/156954.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
current
processing
current transducer
prąd
przetwarzanie
przekładnik prądowy
Opis:
The paper presents a comparative analysis of the two-core Brooks and Brooks &Holtz transformers used in precision measuring systems. The derived relations indicate that the two-core Brooks & Holtz transformer has much better metrological properties. The metrological analysis was verified by the results of tests carried out on standard transformers. The analysis and the results can be used in the design of two-core transformers.
W artykule przedstawiono porównanie właściwości metrologicznych przekładników prądowych Brooksa oraz Brooksa i Holtza [3]. W rozdziale 2.1 przedstawiono przekładnik jednordzeniowy, którego błąd opisano za pomocą impedancji jego obwodu zastępczego (rys. 1b). W rozdziale 2.2 pokazano schemat zastępczy przekładnika Brooksa i na tej podstawie wyprowadzono wzór (2) określający błąd przekładnika. Przy założeniu (3) uproszczono wzór (2) do postaci (5), z którego wynika, że błąd przekładnika zależy głównie od impedancji obciążenia. Pokazano również wpływ błędu przekładnika pomocniczego ACIT (6) na błąd przetwarzania przekładnika Brooksa. Ze wzoru (10) wynika, że magnetowód przekładnika pomocniczego powinien być wykonany z materiału ferromagnetycznego o dużej wartości przenikalności początkowej, tj. permaloj, taśma amorficzna. W rozdziale 2.3 pokazano strukturę i analizę przekładnika Brooksa i Holtza. Z analizy wynika, że przekładnik ten powinien charakteryzować się lepszymi parametrami metrologicznymi, niż przekładnik Brooksa i Holtza, ponieważ w równaniu występuje iloczyn błędów przekładnika głównego i pomocniczego. W rozdziale 3 pokazano zastosowane układy pomiarowe do wyznaczania błędów przekładnika Brooksa (rys. 4) oraz Brooksa i Holtza (rys.5), które realizują metodę kompensacyjno-różnicową. W rozdziale 4 przedstawiono wyniki badań dla błędów prądowych i kątowych. Z otrzymanych wyników badań określono klasę przekładnika Brooksa jako 0,5 oraz dla połączenia Brooksa i Holtza 0,05.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 568-572
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alternatywne metody pomiaru średniego napięcia w elektroenergetycznej sieci rozdzielczej
Alternative methods of MV measurement in distrubution grid
Autorzy:
Olejnik, B.
Powiązania:
https://bibliotekanauki.pl/articles/378248.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
przekładnik napięciowy
sensor pomiarowy
izolator reaktancyjny
dzielnik pojemnościowy
dzielnik rezystancyjno-pojemnościowy
natężenie pola elektrycznego
efekt Pockelsa
Opis:
W artykule przedstawiono wybrane, alternatywne metody pomiaru średniego napięcia w sieci elektroenergetycznej. Rozpatrywane są sposoby możliwe do stosowania tak w rozdzielni, jak i w głębi sieci. Skupiono się głównie na możliwości zastosowania sposobów alternatywnych oraz potencjalnego wykorzystania ich do współpracy z elektroenergetyczną automatyką zabezpieczeniową, gdzie nie zawsze wymagana jest duża dokładność pomiaru. Omawia się przede wszystkim izolatory z wkładkami reaktancyjnymi i rezystancyjnymi jako urządzenia wnętrzowe. Przedyskutowano także możliwość pomiaru napięcia i jego składowych symetrycznych na podstawie analizy pola elektromagnetycznego wokół przewodów linii napowietrznych. W pracy zaprezentowane zostały wyniki badań urządzeń, które mogą posłużyć jako źródło sygnału napięciowego w elektroenergetycznej automatyce zabezpieczeniowej. Przedyskutowano także, w końcowej jej części, wady i zalety konkretnych rozwiązań.
The article presents selected, alternative method of MV measurement in distribution grid. Considered methods are possible for use as a substation, as well as the depth of the network. The focus is mainly on the possibility of using alternative methods and potential use them to cooperate with the power system protection, which does not always require high accuracy. It discusses primarily reactance insulators resistive as indoor unit. Is also discussed the possibility of voltage and its symmetrical components measurement based on the analysis of the electromagnetic field around the conductors of overhead lines. The paper presents the results of equipment tests, which can serve as a source of voltage signal in power automation and protection devices. Discussed are also the advantages and disadvantages of specific solutions.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 78; 97-104
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy przekładników napięciowych podczas pomiaru napięć odkształconych
Measurements of non-sinusoidal voltages with a voltage transformer
Autorzy:
Kaczmarek, M.
Nowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/155751.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik napięciowy
błąd napięciowy
błąd kątowy
jakość energii
napięcie odkształcone
voltage transformer
voltage error
phase displacement
power quality
non-sinusoidal voltage
Opis:
W ocenie jakości energii elektrycznej ogromne znaczenie mają cechy metrologiczne przekładnika, czyli wartości jego błędów napięciowego i kątowego [1]. W artykule zostały przedstawione zastosowane metody pomiarowe oraz wyniki przeprowadzonych analiz umożliwiające określenie dokładności przekładników napięciowych podczas pomiaru napięć odkształconych. Stwierdzono, że podczas takich pomiarów następuje pogorszenie właściwości metrologicznych przekładników napięciowych, co prowadzi do zmniejszenia ich dokładności przy ocenie jakości energii elektrycznej.
Metrological properties of a measuring transformer such as a voltage error and phase displacement are of significant importance in assessment of electric power quality both in steady and transient state [1]. In the paper the method and results of laboratory investigations of the voltage transformer accuracy during measurements of non-sinusoidal voltages are presented. The laboratory tests based on two medium-voltage transformer models and a voltage transformer of type UDZ 24 produced by ABB company were carried out in the measuring circuit shown in Fig. 1. The measurements were taken in the full range of supply voltages and loads of the secondary winding of the voltage transformers in accordance with the standard for determining the accuracy of the inductive voltage transformers [4]. The voltage error and phase displacement of the voltage transformer determined for measurements of non-sinusoidal voltages, shown in Figs. 2 - 5, were compared with the corresponding errors measured for sinusoidal voltages (presented in Table 1). The influence of the conductive disturbances on the voltage transformer errors was determined as the differences between these values. The results of the laboratory investigations show that the metrological properties of a voltage transformer were worse when it was used for measurements of non-sinusoidal voltages. The increase in errors results in the decrease in the accuracy of the power quality determination. In some cases this worsening of the metrological properties causes the decrease in the voltage transformer accuracy class [4].
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 5-7
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu niepoprawnego uziemienia przekładników prądowych w układzie Arona na działanie i wskazania 3-fazowego elektronicznego licznika energii elektrycznej
Analysis of influence of current transformer incorrect ground connections in Aron circuit on power measurement results
Autorzy:
Skórkowski, A.
Skubis, T.
Powiązania:
https://bibliotekanauki.pl/articles/154492.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik prądowy
układ Arona
3-fazowy licznik energii elektrycznej
współczynnik korekcyjny
current transformer
Aron system
3-phase energy meter
correction factor
Opis:
W pracy przedstawiono wpływ błędnego połączenia obwodów wtórnych przekładników prądowych na działanie i wskazania układu pomiarowo-rozliczeniowego energii elektrycznej. Uziemienie końców uzwojeń stron wtórnych przekładników prądowych zamiast początków skutkuje zmianą rozpływu prądów w torach prądowych licznika. Przeanalizowano sposób określenia współczynnika korek-cyjnego dla błędnie połączonego układu oraz wielkości mających wpływ na jego wartość.
Influence of incorrect connection of current transformer secondary circuits in Aron circuit on the operation of 3-phase electronic meas-uring and billing system of electrical energy in this paper has been described. Grounding the ends of secondary windings of current transformers instead of beginnings ones causes the current flow change in the measuring system, what was never reported before. Such a mistake connection can happen during the energy meter installation, and is difficult to the detection. It results in significant change of measurement results, lowering the cost of energy to be paid. The explanation of the grounding connection influence into measurement results is given in the paper. The correction factor for long time working incorrectly grounded system is calculated.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 10, 10; 829-832
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania symulacyjne przekładnika ciśnienia w kontekście jego oporów ruchu
Simulation tests of relay valve in the context of its resistances to motion
Autorzy:
Tomaszewski, Sylwin
Frączek, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/34112023.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
simulation studies
relay valve
resistance movement
hysteresis
pressure cylinder
badania symulacyjne
przekładnik ciśnienia
opór ruchu
histereza
ciśnienie cylindrowe
Opis:
W artykule przedstawiono opis przekładnika ciśnienia cylindrowego zaprojektowanego i wykonanego przez Instytut Pojazdów Szynowych „TABOR”. Scharakteryzowano poszczególne elementy składowe jego budowy oraz wytypowano te, które mają istotny wpływ na zmianę oporów ruchu przekładnika ciśnienia. Przedstawiono aktualnie obowiązujące kryteria dotyczące parametrów działania przekładnika ciśnienia cylindrowego. Zaprezentowano wybrane wyniki badań, które polegały na ustaleniu wpływu oporów ruchu na zmianę wartości histerezy oraz poprawności działania przekładnika ciśnienia. Pokazano stanowisko, na którym przeprowadzono badania symulacyjne działania przekładnika ciśnienia oraz stanowisko do pomiarów oporów ruchu. W artykule przedstawiono także komputerowy model symulacyjny, w którym weryfikowano wyniki badań.
The article presents the description of the cylinder relay valve designed and made by the Rail Vehicles Institute "TABOR". The individual components of its construction were characterized and it was selected those that have the significant influence on change of resistances to motion of the relay valve. The currently applicable criteria concerning the operating parameters of the cylinder relay valve are presented. The selected results of the tests which consisted in determining the impact of resistances to motion on change of the hysteresis values and the correctness of operation of the relay valve are presented. The stand, on which the simulation tests of relay valve operation were carried out, and the stand for measurements of resistances to motion are shown. The article also presents a computer simulation model in which the results were verified.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2016, Nr 3; 39-47
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór elementów przekładnika ciśnienia i ich wpływ na parametry pracy
Selection of pressure transducer components and their influence on the operation parameters
Autorzy:
Tomaszewski, Franciszek
Tomaszewski, Sylwin
Powiązania:
https://bibliotekanauki.pl/articles/34670824.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
przekładnik ciśnienia
parametry działania
lokomotywa
wagon
jednostka trakcyjna
wartość histerezy
algorytm sterowania
pressure transducer
performances
locomotive
car
traction unit
hysteresis
control algorithm
Opis:
W artykule przedstawiono zakres stosowania przekładników ciśnienia dla poszczególnych pojazdów szynowych z rozbiciem na lokomotywy, wagony i jednostki trakcyjne. Przedstawiono opis przekładnika ciśnienia cylindrowego zaprojektowanego i wyprodukowanego przez Instytut Pojazdów Szynowych „TABOR”. Scharakteryzowano poszczególne elementy składowe jego budowy oraz wytypowano te, które mają istotny wpływ na zmianę parametrów pracy przekładnika ciśnienia. Przedstawiono aktualnie obowiązujące kryteria dotyczące parametrów działania przekładnika ciśnienia cylindrowego. Zaprezentowano wybrane wyniki badań, które polegały na ustaleniu wpływu parametrów sprężyny na zmianę wartości histerezy oraz poprawności działania przekładnika ciśnienia. Wartość histerezy oceniano bezwymiarową wielkością zwaną sprawnością przekładnika, analizując przebiegi ciśnień podczas hamowania i luzowania oraz stopniowego hamowania realizowanego przez przekładnik ciśnienia. W pracy zaprezentowano stanowisko do badań, na którym, przy pomocy mikroprocesorowego układu sterowania, zadawano odpowiednie przebiegi wartości ciśnień zgodnie z algorytmem sterowania stworzonym specjalnie do tego celu.
The article presents the scope of use of pressure transformers for individual rail vehicles, broken down into locomotives, wagons and traction units. A description of the cylinder pressure transformer designed and manufactured by the Rail Vehicles Institute "TABOR" is presented. The individual components of its structure were characterized and those that have a significant impact on changing the operating parameters of the pressure transformer were selected. The currently applicable criteria regarding the operating parameters of the cylinder pressure transformer are presented. Selected test results were presented, which consisted in determining the influence of spring parameters on the change in the hysteresis value and the correct operation of the pressure transformer. The hysteresis value was assessed with a dimensionless quantity called the efficiency of the transformer, by analyzing the pressure patterns during braking and release as well as gradual braking performed by the pressure transformer. The work presents a test stand in which, using a microprocessor control system, appropriate pressure values were set in accordance with a control algorithm created especially for this purpose.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2014, 4; 14-19
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of selected lubricants on operation of relay valves of braking systems of rail vehicles
Wpływ wybranych środków smarnych na działanie przekładników ciśnienia układów hamulcowych pojazdów szynowych
Autorzy:
Tomaszewski, Sylwin
Tomaszewski, Franciszek
Strzemkowski, Jan
Powiązania:
https://bibliotekanauki.pl/articles/33720182.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Poznański Instytut Technologiczny
Tematy:
lubricant
relay valve
braking system
rail vehicle
środek smarny
przekładnik ciśnienia
układ hamulcowy
pojazd szynowy
Opis:
The article presents the relay valve of braking systems of rail vehicles and its functions. Because of their function in braking systems the relay valves should be characterized by high reliability and correct carrying out the tasks in the braking system of rail vehicles. The stand tests of relay valves have shown that the properties of the applied grease have a big influence on the correctness of the relay valves' functioning. The paper presents the test stand and the results of tests of lubricants used in the relay valves. The idea of carried out tests of the values of lubricants parameters in different temperatures is discussed. The analysis of the test results of the lubricant parameters and the tests of the relay valves on the test stand showed that the correctness of the relay valves operation depends on the properties of the used lubricant. On the basis of the carried out tests, a grease was selected, which especially in low temperatures, meets the criteria of the correct and reliable operation of relay valves in rail vehicles.
W artykule przedstawiono przekładnik ciśnienia układów hamulcowych pojazdów szynowych oraz jego funkcje. Przekładniki ciśnienia z racji spełnianych funkcji w układach hamulcowych powinny charakteryzować się dużą niezawodnością oraz poprawnym wypełnianiem zadań w układzie hamulcowym pojazdów szynowych. Badania stanowiskowe przekładników ciśnienia wykazały, że duży wpływ na poprawność funkcjonowania przekładników mają właściwości zastosowanego smaru. Przedstawiono również stanowisko do badań oraz wyniki badań środków smarnych stosowanych w przekładnikach ciśnienia. Omówiono ideę przeprowadzonych badań wartości parametrów środków smarnych w różnych temperaturach. Analiza wyników badań parametrów środków smarnych oraz badań przekładników na stanowisku badawczym wykazała, że poprawność działania przekładników ciśnienia zależy od właściwości zastosowanego środka smarnego. Na podstawie przeprowadzonych badań wybrano smar, który szczególnie w niskich temperaturach, spełnia kryteria poprawnego i niezawodnego działania przekładników ciśnienia w pojazdach szynowych.
Źródło:
Rail Vehicles/Pojazdy Szynowe; 2018, Nr 3; 18-24
0138-0370
2719-9630
Pojawia się w:
Rail Vehicles/Pojazdy Szynowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja kształtu prądu wtórnego przekładnika prądowego
Correction of the Secondary Current Shape of Current Transformer
Autorzy:
Biel, B.
Jakubowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1368621.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
przekładnik prądowy
uzwojenie wtórne
krzywa magnesowania
pętla histerezy
energia strat w rdzeniu
przebieg odkształcony
błąd prądowy
błąd całkowity
błąd kształtu
current transformer
secondary winding
magnetization curve
hysteresis loop
energy loss in the core
process deformed
current error
total error
shape error
Opis:
The currents measured in industrial applications reach very high values and at the same time their courses are more and more distorted. In the case of the measurement of alternating current of very high intensity it is necessary to use a current transformer. Such a current transformer should only change the scale of the course but retain its shape. Unfortunately, current transformers distort the shape of the course. These distortions depend mainly on the harmonic content in the primary current and the distortions caused by the ferromagnetic core. The purpose of the article is to define the methodology to minimize the distortion of the secondary current caused by the current transformer, while leaving the distortion of the original course. Minimizing distortions does not consist in the idealization of core parameters but on the development of the algorithm for processing samples using the CT ratio parameters. In this method CT ratio parameters are determined on the basis of the data specified on the nameplate as well as on the basis of measurements. These measurements are carried out without intervention in its interior. The method presented enables more accurate reproduction of the shape of current being measured and can be applied in the industry. The method can be used both for transformers at the design stage and those already in operation.
Prądy mierzone w zastosowaniach przemysłowych osiągają bardzo duże wartości, a jednocześnie kształty przebiegów są coraz bardziej odkształcone. W przypadku pomiaru prądu zmiennego o dużym natężeniu musi być stosowany przekładnik prądowy. Stosowany przekładnik powinien tylko zmienić skalę przebiegu, zachowując jego kształt. Niestety przekładniki prądowe zniekształcają jego kształt. Zniekształcenia te zależą głównie od zawartości harmonicznych w prądzie pierwotnym oraz zniekształceń wprowadzanych przez rdzeń ferromagnetyczny. Celem artykułu jest określenie metodyki zminimalizowania zniekształceń przebiegu prądu wtórnego wprowadzanych przez przekładnik, przy pozostawieniu zniekształceń przebiegu pierwotnego. Minimalizacja zniekształceń nie polega na idealizacji parametrów rdzenia, ale na opracowaniu algorytmu przetwarzania próbek, przy wykorzystaniu parametrów przekładnika. W metodzie tej parametry przekładnika określa się na podstawie danych z tabliczki znamionowej oraz pomiarów. Pomiary te wykonywane są bez ingerencji w jego wnętrze. Przedstawiona metoda umożliwia dokładniejsze odwzorowanie kształtu przebiegu prądu mierzonego i będzie mogła być stosowana w przemyśle. Może być ona stosowana do przekładników zarówno projektowanych jak i już będących w eksploatacji.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 7-12
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda analizy obwodów wejściowych systemów pomiarowych pracujących z sygnałami elektroenergetycznymi
The method used for analysis of input circuits working with electroenergetical signals
Autorzy:
Rzeszutko, J.
Powiązania:
https://bibliotekanauki.pl/articles/156000.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
indukcyjny przekładnik napięcia
estymacja transmitancji częstotliwościowej
obwody wejściowe
spectral transmittance estimation
frequency characteristics
THD
input circuits
Opis:
Monitorowanie jakości dostarczanej energii elektrycznej jest problemem aktualnym, któremu poświęca się wiele uwagi. Systemy pomiarowe wykonujące tego typu pomiary muszą posiadać odpowiednie własności metrologiczne. Podstawowym elementem aparatury pomiarowej, monitorującej jakość przesyłanej energii elektrycznej są obwody wejściowe. Do ich budowy stosuje się m.in.: indukcyjne przekładniki napięcia, dzielniki pojemnościowe lub rezystancyjne, układy wykorzystujące modulację światła. Zapoznając się z najnowszymi publikacjami z tej tematyki, można dojść do wniosku, że brak wiedzy o wpływie obwodów wejściowych na mierzony sygnał, w całym jego zakresie częstotliwości prowadzi do niepoprawnych wyników. Znając charakterystyki częstotliwościowe obwodów wejściowych można ocenić ich wpływ na niepewność pomiarów mocy i energii oraz wskaźników odkształceń przebiegów napięć i prądów. W artykule przedstawiono metodę, która umożliwia estymacje transmitancji częstotliwościowej obwodów wejściowych zbudowanych z indukcyjnego przekładnika napięcia oraz filtru aktywnego 8-go rzędu. Metoda ta wykorzystuje widmowe gęstości mocy sygnałów napięć, co pozwala na identyfikację charakterystyki amplitudowo-częstotliwościowej oraz fazowo-częstotliwościowej obwodów wejściowych bez konieczności dysponowania wyspecjalizowaną aparaturą pomiarową.
The paper describes the method used to estimate frequency characteristics of input circuits used in power measurement systems. The advantage of this method is the ability to estimate the tested object spectral transmittance without the need to provide a specialized measuring instrument. Identification of the transmittance is performed by observing signals at the input and output of the tested object. From that we can estimate the spectral power density of the input signal and cross-spectral power density between the input signal and its response. This allows the estimation of spectral transmittance according to formula (1). Details of these calculations are shown in [3]. There was conducted an experiment aiming at determining the frequency characteristics of input circuits containing an inductive voltage transformer and eight row active filter. In addition to this, a measurement scheme was prepared as depicted in Fig. 1. The next step was to measure signals at the input and output of the input circuit (Fig. 2) and to determine the frequency spectrum (Fig. 3). For the harmonics presented in the analysed signals it was possible to estimate the frequency characteristic, result of which is shown in Figs. 4 and 5. Based on the experiment results, it should be noted that these particular input circuits are not to be used in a device for measuring parameters of power quality. The reason for this is that the inductive voltage transformer used in the experiment has a strong, nonlinear amplitude-frequency response. For this reason the obtained results would be biased.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1573-1575
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miniaturowy przekładnik napięciowy do współpracy z nowoczesnymi układami monitorująco-zabezpieczającymi
Miniature voltage transformer for operation within innovative monitoring-protecting systems
Autorzy:
Szkółka, S.
Szymański, A.
Wiśniewski, G.
Powiązania:
https://bibliotekanauki.pl/articles/187684.pdf
Data publikacji:
2009
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
Instytut Energoelektryki Politechniki Wrocławskiej
przekładnik napięciowy
Institute of Electrical Power Engineering of Wrocław University of Technology
voltage transformer
Opis:
W artykule przedstawiono jedną z trzech opracowanych w Instytucie Energoelektryki Politechniki Wrocławskiej koncepcji przekładnika napięciowego ułamkowej mocy dedykowanego współczesnym układom pomiarowym i monitorującym, bazującym na technice mikroprocesorowej. Zamieszczono wstępne wyniki badań odnośnie do wierności transformacji.
One of three ideas of a voltage transformer of a very low power developed by the Institute of Electrical Power Engineering of Wrocław University of Technology has been presented in the paper. The voltage transformer will be designed for innovative present-day measuring and monitoring systems based on microprocessor technology. The first research and test results regarding transformation fidelity have been shown.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2009, R. 47, nr 7, 7; 14-19
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowy model elektronicznego przekładnika prądowego z kompensacją strumienia magnetycznego w rdzeniu
A new electronic transducer model with magnetic flux compensation in magnetic core
Autorzy:
Piwowarczyk, J.
Pacholski, K.
Powiązania:
https://bibliotekanauki.pl/articles/156292.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektroniczny przekładnik prądowy
pomiar prądu
electronic current transducer
current measurement
Opis:
Przedstawiono nowy model elektronicznego przekładnika prądowego. Punktem wyjścia do realizacji tego modelu był model konwencjonalnego przekładnika prądowego, który połączono następnie z modelem bloku elektroniki. Tego typu podejście odzwierciedla budowę rzeczywistego układu. Parametry modelu elektronicznego przekładnika prądowego uzależniono od pulsacji sygnału mierzonego. Pozwoliło to nie tylko na analizę właściwości metrologicznych obiektu badań, ale i również na wyznaczenie częstotliwości ograniczającej od góry częstotliwościowe pasmo przetwarzania bloku elektronicznego. Autorzy dokonali weryfikacji nowego modelu przetwornika w trakcie badań laboratoryjnych.
The paper describes new electronic current transducer model. Starting point during constructing the new model was the model of typical current transducer that was connected to the electronic model block. Such solution reflect to the real object. The parameters of the electronic current transducer model were combined with pulsation of the primary signal. It allowed to analyse metrological properties of the object as well as to determine upper frequency, that limits electronic block work. Authors performed verification of the new transducer model during laboratory research.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 669-672
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nowy sposób minimalizacji błędów przetwarzania elektronicznych przekładników prądowych
New method, of the minimization of the electronic current transducer processing errors
Autorzy:
Szczęsny, A.
Pacholski, K.
Powiązania:
https://bibliotekanauki.pl/articles/158029.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
elektroniczny przekładnik prądowy
impedancja aktywna
electronic current transducer
active impedance
Opis:
Wyniki analizy właściwości przekładników elektronicznych wykazały, że w paśmie częstotliwości, w którym przekładnik jest wspomagany elektro-nicznie, wartości błędów przetwarzania, są mniejsze w porównaniu z błędami przekładnika pracującego bez wspomagania. Zdaniem autorów, najbardziej wydajnym sposobem minimalizacji błędów przekładników, jest prezentowany w referacie sposób wykorzystujący dynamiczną reduk-cję impedancji obwodu kompensującego strumień magnetyczny w rdzeniu, pozwalający na rozszerzenie pasma pracy bloku elektronicznego bez ingerencji w ich strukturę wewnętrzną.
Verified with laboratory-research the results of analysis the basis of function showed that transducers aided electronically can processing the de-formed current at the frequency to belong to the band of work of electronic block controlling of the compensation circuit of the stream in the core. A reason of limitation the band of work of this block is the saturation two transistors, determining the power output-degree the electronic block of transducer. The method permissive on the reduction of deviations put in by transducers helped electronically without the interference into its structure is not exist till now. In opinion of authors, a most effective method of correction of errors, is presented in paper the method which used dynamic reduction of the impedance of the circuit compensating. Presented below the method of the minimization of electronic transducers errors can be use for accessible on the market of system without the intervention into their internal structure.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 12, 12; 18-20
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary pomontażowe urządzeń i sieci elektroenergetycznych średniego napięcia SN
Post-assembly measurements of devices and energy network for MV power grids
Autorzy:
Chrzan, M.
Moszyński, S.
Pietruszczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/310356.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
pomiary pomontażowe
przekładnik prądowy
sieć elektroenergetyczna
sieć średniego napięcia SN
wyłącznik średniego napięcia SN
post-assembly measurements
current transformer
power grid
medium voltage MV power grids
MV voltage switch
Opis:
W artykule przedstawiono analizę pomiarów pomontażowych urządzeń i sieci elektroenergetycznych średniego napięcia SN. Przedstawiono je na przykładach urządzeń przesyłowo-rozdzielczych występujących w różnych zakładach przemysłowo-wytwórczych w Polsce.
The paper presents the analysis of post-assembly measurements of devices and energy network for MV power grids. They are presented on the examples of transmission and distribution devices present in various industrial and manufacturing plants in Poland.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 341-349
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praca bezpiecznika przekładnika średniego napięcia w warunkach ferrorezonansu
Operation of fuses to medium voltage measuring transformers under ferroresonance condictions
Autorzy:
Tłustochowicz, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/268080.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
ferrorezonans
bezpiecznik przekładnikowy
przekładnik
przepięcie
ferroresonance
voltage transformer's fuse
voltage transformer
overvoltage
Opis:
Obserwowane są przypadki działania bezpieczników średnich napięć chroniących przekładniki napięciowe od skutków przetęSeń podczas ferrorezonansu napięć. W artykule przed-stawiono wyniki badań symulacyjnych wpływu zjawisk ferrorezonansowych na pracę bezpiecznika SN. Ferrorezonans moSe wystąpić w wyniku nagłej zmiany napicia pracy przekładnika, której przyczynami mogą być przepięcia łączeniowe lub atmosferyczne. Wyniki badań symulacyjnych nie wykluczają moSliwości działania bezpiecznika przekładnika SN w następstwie zjawisk ferrorezonansowych, powodowanych przepięciem. Przypadki takich zdarzeń są rejestrowane w praktyce eksploatacji sieci średnich napięć i potwierdzone badaniami laboratoryjnymi.
There are observed some cases of maloperation of fuses, which are used to the protection of medium voltage measuring transformers against results of overcurrents at voltage ferroresonance. The paper presents results of simulation study of the effect of ferroresonance phenomena upon medium voltage fuse operation. The ferroresonance may occur at a sudden change of measuring transformer operation voltage, which may result, e.g. from switching overvoltages or lightning surges. Simulation study has not excluded maloperation of a fuse to medium voltage measuring transformer resulting from ferroresonance phenomena. Such events have been registered in practice, in operation of medium voltage networks and confirmed by laboratory experiments.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2009, 26; 117-120
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ pomiaru symetrycznych i asymetrycznych prądów zwarciowych z zastosowaniem wielozakresowych przekładników prądowych w warunkach laboratorium zwarciowego
The system of measurement of symmetrical and asymmetric short circuit current with multi range current transformers in conditions of short-circuit testing laboratory
Autorzy:
Babiuch, Michał
Olak, Jan
Powiązania:
https://bibliotekanauki.pl/articles/267651.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
badania zwarciowe
pomiar prądów zwarciowych
przekładnik prądowy
short-circuit test
short-circuit current measurement
current transformer
Opis:
W artykule przedstawiono różne wymagania zawarte w normach przedmiotowych, dotyczące parametrów probierczych dla aparatury elektroenergetycznej i różnych rodzajów badań wykonywanych w laboratorium zwarciowym. Opisano wyposażenie badawczo pomiarowe Zwarciowni Instytutu Elektrotechniki w Warszawie (IEL). Przedstawiono układ pomiaru prądów zwarciowych przy użyciu nowo opracowanych przekładników. Opisano metodę sprawdzenia dokładności przekładników prądowych do pomiaru prądów zwarciowych i zamieszczono przykładowe wyniki i oscylogramy z badań. Układ został wdrożony i jest eksploatowany w Zwarciowni IEL.
The article contains an overview of various requirements for the parameters of the Short-Circuit Testing Laboratory: symmetrical and asymmetrical short-circuit currents, time constant for the disappearance of the constant short-circuit component, asymmetrical peak factor and various types of short-circuit tests performed on various devices operating in power systems, contained in different subject standards . The equipment of the Short-Circuit Testing Laboratory of the Electrotechnical Institute and the modernized test chamber No. 6 is described, equipped with new multi range current transformers and a modern measuring system for short-circuit current. The method of checking the accuracy of current transformers for measuring short-circuit currents is described and example oscillograms are given. The values of the adopted parameters of the transformers and the way of designing the test track are highlighted, enabling the simplification of preparatory works to carry out short-circuit tests and research organization. The article contains electrical diagrams of measurement systems, diagrams of current transformer windings and photograph of modernized test chamber No. 6.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies