Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "protetyka" wg kryterium: Temat


Tytuł:
The influence of saliva and its substitutes on corrosion of some implant alloys
Autorzy:
Andrysewicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/387260.pdf
Data publikacji:
2013
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
metallic alloys
corosion
human saliva
saliva substitute
prosthodontia
stopy metalu
korozja
ludzka ślina
substytut śliny
protetyka stomatologiczna
Opis:
The purpose of this paper is evaluation of the influence of human saliva and its substitutes on the corrosion re sistance of some implant alloys used in stomatology, which included: austenitic steel (316L), titanium alloy (Ti6Al4V), and cobalt alloy (CoCrMo). Corrosion studies were conducted by means of the potentiodynamic method with the application of the VoltaLab 21 kit with VoltaMaster 4 software. The reference electrode was a saturated calomel electrode (SCE), whereas the counter electrode was a platinum electrode. The results of conducted studies indicate an increased current density in the passive range on potentiodynamic curves of studied alloys in the envi- ronment of human saliva, and also in a commercial saliva solution – Mucinox. On the basis of conducted corrosion studies, it can be stated that in terms of corrosion resistance the developed saliva substitutes may constitute competitive solutions to commercial saliva substitutes. The prepared substitutes should be studied further from the perspective of practical application for patients. The original value of the paper is a proposition of new saliva substitutes.
Źródło:
Acta Mechanica et Automatica; 2013, 7, 2; 69-74
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania materiałowe i korozyjne konwencjonalnych stopów Co-Cr-Mo-W przeznaczonych na odlewy konstrukcji szkieletowych w protetyce dentystycznej
Material and corrosion studies of conventional Co-Cr-Mo-W alloys for frame construction casts in dental prosthetics
Autorzy:
Augustyn-Pieniążek, J.
Łukaszczyk, A.
Loch, J.
Powiązania:
https://bibliotekanauki.pl/articles/285880.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
konwencjonalne stopy na osnowie kobaltu
protetyka dentystyczna
roztwór sztucznej śliny
odporność korozyjna
woltamperometria liniowa
conventional cobalt-based alloys
dental prosthetics
artificial saliva solution
corrosion resistance
linear sweep voltammetry
Opis:
Podstawowe cechy jakimi powinny charakteryzować się materiały stosowane na protezy szkieletowe w stomatologii to biotolerancja w środowisku tkanek i płynów ustrojowych oraz duża odporność na korozję wżerową i szczelinową. Ważna jest również stabilność zespołu określonych własności fizyczno-mechanicznych (wysoka wytrzymałość, odpowiednia ciągliwość, twardość i odporność na ścieranie) oraz jednorodność składu chemicznego W pracy przedstawiono wyniki badań konwencjonalnych stopów odlewniczych Co-Cr-Mo-W stosowanych do wykonywania odlewów szkieletów protez ruchomych, koron i mostów w protetyce dentystycznej. Badania wykonano na czterech stopach Co-Cr-Mo-W o różnej zawartości Mo, W oraz innych domieszek. W pracy dokonano analizy mikrostruktury stopów z zastosowaniem mikroskopu świetlnego oraz elektronowego mikroskopu skaningowego. Dodatkowo wykonano pomiary mikrotwardości metodą Vickersa oraz badania odporności korozyjnej. Dla każdego z badanych stopów Co-Cr-Mo-W wykreślono zależność potencjału stacjonarnego w funkcji czasu oraz wykonano badania woltamperometryczne w środowisku sztucznej śliny. Przeprowadzone obserwacje metalograficzne pozwoliły stwierdzić, że analizowane materiały charakteryzowały się budową dendrytyczną typową dla stopów odlewanych. Mikrostruktura ta jest chemicznie niejednorodna, złożona z austenitycznej osnowy składającej się z roztworu stałego kobaltu oraz chromu w rdzeniowej strukturze dendrytycznej. Stopy charakteryzowały się wysoką twardością. Wzrost mikrotwardości jest silnie determinowany występowaniem wydzieleń węglikowych M23C6, które zapewniają dużo silniejsze umocnienie stopu. Analizowane stopy wykazywały zbliżone przebiegi krzywych polaryzacji. Zachowanie elektrochemiczne stopów Co-Cr-Mo-W w dużej mierze zależy od zawartości w stopie chromu i molibdenu, pierwiastków, które przyczyniają się do pasywacji stopów.
The basic characteristics of skeletal prosthetic materials used in dentistry are: biotolerance with tissues and body fluids, as well as high pitting and crevice corrosion resistance. Also important are such characteristics as: high strength, adequate ductility, hardness and abrasion resistance, as well as homogeneity of the chemical composition. The work presents the results of the studies of conventional Co-Cr-Mo-W casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo-W alloys of different contents of Mo, W and other additives. The work analyzes the alloys microstructures with the use of a light microscope and a scanning electron microscope. Additionally, hardness measurements were made by means of the Vickers method and corrosion resistance tests were conducted. For each examined Co-Cr-Mo-W alloy, the open circuit potential as a function of time was determined and voltamperometric tests were performed in artificial saliva. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure. The investigated alloys were characterized by high hardness. The increase in the microhardness was depended on the presence of carbide precipitates M23C6, which provide a much stronger reinforcement of the alloy. The analyzed materials exhibited a similar progress of the polarization curves. The electrochemical corrosion of Co-Cr-Mo-W alloys was depended on the content of chromium and molybdenum, which largely contributed to alloy passivation.
Źródło:
Engineering of Biomaterials; 2015, 18, 130; 2-9
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Qualitative Assessment of the Defects in Metal Casting Prosthetic Restorations
Autorzy:
Augustyn-Pieniążek, J.
Wilkosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/379721.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt based alloys
casting defects
dental prosthetics
3D scanner
kobalt
wady odlewnicze
protetyka stomatologiczna
skaner 3D
Opis:
Due to the frequent occurrence of casting defects in the casting process of metal prosthetic elements, studies aiming at identifying the defects and determining their probable causes were performed. The work presents the results of the examinations of the Co-Cr-Mo alloy, brand name Argeloy N.P. Special, used for prosthetic restorations. Macroscopic and microscopic observations were conducted with the use of light and scanning microscopy (SEM). Also, the results of the observations by means of a 3D scanner by GOM ATOS 3 were presented. The performed research made it possible to determine and classify casting defects such as blisters, misruns and interscrystalline cracks. It was stated that a stabilized technological process affects the elimination of the casting defect formation.
Źródło:
Archives of Foundry Engineering; 2014, 14, 4 spec.; 7-12
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected properties and tribological wear alloys Co-Cr-Mo and Co-Cr-Mo-W used in dental prosthetics
Wybrane właściwości oraz zużycie tribologiczne stopów, Co-Cr-Mo i Co-Cr-Mo-w stosowanych w protetyce stomatologicznej
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Sulima, I.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/356345.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Co-Cr alloys
wear
slurry abrasion test (“Miller test”)
dental prosthetics
Co-Cr stopy
zużycie
badanie zużycia ściernego stopów
aparat Millera
protetyka stomatologiczna
Opis:
The presented work provides the results of the abrasive wear resistance tests performed on Co-Cr-Mo and Co-Cr-Mo-W alloys with the use of the Miller’s apparatus. The analyzed alloys underwent microstructure observations as well as hardness measurements, and the abraded surfaces of the examined materials were observed by means of electron scanning microscopy. The performed examinations made it possible to state that the Co-Cr alloys characterized in a high hardness, whereas the changes in the mass decrement were minimal, which proved a high abrasive wear resistance.
W prezentowanej pracy przedstawiono wyniki badań zużycia ściernego stopów, Co-Cr-Mo i Co-Cr-Mo-W przy użyciu aparatu Millera. Analizowane stopy poddano obserwacjom mikrostruktury, pomiarom twardości i mikrotwardości, a ścierane powierzchnie badanych materiałów obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Przeprowadzone badania pozwoliły na stwierdzenie, że stopy, Co-Cr charakteryzowały się wysoką twardością i mikrotwardością, zaś zmiany ubytku masy były bardzo minimalne, co świadczy o wysokiej odporności na ścieranie.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1569-1574
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości ścierne stopów Co-Cr w zawiesinie ceramika-sztuczna ślina
Abrasive behaviour of Co-Cr alloys in the ceramic material-artificial saliva suspension
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/284452.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy Co-Cr
testy zużycia ściernego w zawiesinie
protetyka stomatologiczna
Co-Cr alloys
abrasive wear tests in suspension
prosthodontics
Opis:
Publikacja zawiera wyniki badań odporności na ścieranie stopów Co-Cr-Mo i Co-Cr-Mo-W przeprowadzonych na aparacie Millera. W celu oceny podatności na zużycie ścierne w naturalnych warunkach pracy w/w stopów, badania prowadzono w specjalnie zasymulowanym środowisku, składającym się z ceramicznego proszku Dentyna oraz roztworu sztucznej śliny o pH równym 6,7. W ramach badań przeprowadzono obserwacje mikrostruktury przy wykorzystaniu mikroskopu świetlnego stosując kontrast interferencyjno--różniczkowy (kontrast Nomarskiego), wykonano pomiary twardości, zaś powierzchnie po procesie ścierania poddano obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Na postawie przeprowadzonych badań stwierdzono, że stopy Co-Cr-Mo i Co-Cr-Mo-W charakteryzują się wysoką twardością około 400-450 HV10 i minimalnym ubytkiem masy w procesie ścierania. Cechy te świadczą o wysokiej odporności na ścieranie badanych stopów w środowisku proszek ceramiczny-sztuczna ślina. Dodatkowo stwierdzono również, że trzy z badanych stopów Remanium 2001, Colado CC oraz Heraenium P w odróżnieniu od stopu Wironit LA, posiadają przystanki na krzywych ubytku masy w czasie związane z różnicami twardości materiału osnowy β-Co, wydzieleń węglikowych oraz ramion dendrytów. W przypadku stopu Wironit LA obserwowano równomierne zużycie materiału na całej powierzchni. Stwierdzono również, że pomimo różnic w mechanizmach ścierania pomiędzy stopem Wironit LA I Remanium 2001 wielkość ubytku masy jest dla nich na podobnym poziomie, jednak jest ona znacznie niższa niż dla pozostałych dwóch badanych stopów Colado CC ora Heraenium P.
The publication contains the results of the abrasion resistance tests carried out on Co-Cr-Mo and Co-Cr--Mo-W alloys using Miller apparatus. To assess the susceptibility to abrasive wear of the above mentioned alloys under natural operating conditions, tests were carried out in a specially simulated environment, consisting of a ceramic Dentine powder and artificial saliva solution with pH of 6.7. The scope of studies included the examinations of microstructure performed by light microscopy using differential interference contrast (Nomarski contrast), measurements of hardness, and SEM examinations of surfaces after the abrasion process. The results of these studies enabled formulating the conclusion that alloys from the Co-Cr-Mo and Co-Cr-Mo-W systems are characterised by high hardness of about 400-450 HV10 and minimum weight loss in the process of abrasion. These features prove high abrasive wear resistance of the examined alloys in the environment of ceramic powder and artificial saliva. Additionally, it was also found that three of the tested alloys, i.e. Remanium 2001, Colado CC and Heraenium P, unlike the Wironit LA alloy, show time-related arrests on the weight loss curves caused by different hardness values of the β-Co matrix, carbide precipitates and dendrite arms. The Wironit LA alloy was observed to wear evenly across the whole surface. It was also found that, despite differences in abrasion mechanism operating in the Wironit LA and Remanium 2001 alloys, the magnitude of weight loss has been similar and, at the same time, much lower than for the other two alloys tested, i.e. Colado CC and Heraenium P.
Źródło:
Engineering of Biomaterials; 2014, 17, 127; 7-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura i własności mechaniczne modyfikowanych stopów CoCrMo do zastosowań w protetyce stomatologicznej
Structure and mechanical properties of modified CoCrMo alloys for use in dental prosthetics
Autorzy:
Beer, K.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/285534.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
protetyka stomatologiczna
biomateriały
stopy CoCrMo
dental prosthetics
biomaterials
Co-Cr-Mo alloys
Opis:
Większość klinicznych niepowodzeń w przypadku protez stomatologicznych związana jest przede wszystkim z techniką wytapiania i odlewania oraz ilością użytego do wsadu stopu już raz przetopionego. W pracy dokonano analizy wpływu ilości materiału z recyklingu na właściwości mechaniczne i strukturę stomatologicznego stopu CoCrMo. Zastosowano metodę odlewania odśrodkowego, oraz jednokrotne przetopy o składzie wyjściowym odpowiednio 0, 25, 50, 75 i 100% złomu. Przeprowadzono statyczną próbę rozciągania, pomiar mikrotwardości, analizę mikrostrukturalną oraz obserwację SEM przełomów. Stwierdzono, że własności mechaniczne wszystkich przetapianych stopów są gorsze niż stopu czystego, zakupionego u zagranicznego producenta. Mikrostruktura przełomów przetapianych stopów z zawartością złomu powyżej 50% jest bardziej niejednorodna i w strukturze dendrytycznej widoczna jest większa ilość mikropęknięć. Podczas zrywania próbek zarejestrowano wyraźne obniżenie granicy plastyczności i wytrzymałości tych stopów w próbach zrywania w porównaniu z próbkami ze stopów zawierających mniejszą ilość materiału z recyklingu.
The majority of clinical failures in the case of dental prostheses is associated primarily with the technique and the amount of remelted alloy used for the casting. The majority of clinical failures in the case of dental prostheses is associated primarily with the technique of remelting and casting, and quantity of the once remelted alloy used for the batch. The paper analyzes the impact of the amounts of recycled material on the mechanical properties and structure of dental alloy CoCrMo. The centrifugal casting method has been applied and remelted alloys with output composition of 0, 25, 50, 75 and 100% of scrap respectively. The static tensile test, microstructural analysis and SEM observation as well as microhardness test have been conducted. These all tests show that the mechanical strength of all remelted alloys is worse than the strength of the fine alloy, purchased from a foreign manufacturer. The microstructure of breakthroughs of the remelted alloys containing more than 50% of scrap is more heterogeneous and a higher amount of microcracks is visible in the dendritic structure. When the samples were tested in the static tension test, the significant decrease in the yield strength and the tensile strength of these alloys during these static tension tests in comparison to the samples of alloys containing lower amount of the recycled material were observed.
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 110-115
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Embedded systems ensuring safety for people with disabilities
Autorzy:
Chajduga, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1831326.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
embedded systems
disability
ensuring safety
programmable prosthese
intelligent prosthetics
systemy wbudowane
inwalidztwo
zapewnienie bezpieczeństwa
programowalna proteza
inteligentna protetyka
Opis:
The publication discusses the concept of modern embedded systems that can be programmed and build in bigger systems in order to ensure the safety of people with disabilities. Article presents the definition of embedded system and, also, introduces the definition of the author. What is more, article briefly presents the most popular and developed in the fastest way exemplary systems: ARM, STM32, Raspberry PI, Sony Spresense and NvidiaJetson. Moreover, the main reasons were described why the embedded systems are used in more and more solutions and the factors that strengthen this trend have been noted: labor costs reduction through automation, reduction of costs of development of a new product through the possibility of making quick changes and reduction of product testing time, value creation potential and, also, the way to individualize the possibilities of electronics. Also, the examples of usage of those systems were presented. Finally, the practical side of programming and testing the embedded systems were described: ‘radar‘ (a torch) for blind people, help with balance disorders and the device to help with problems with orientation in space. In the conclusions, author shapes the estimated potential future of electronics supported with modern embedded systems, which as author believes makes this article the comprehensive study.
Źródło:
System Safety : Human - Technical Facility - Environment; 2021, 3, 1; 296-303
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of friction in the mechanism of retaining the partial removable dentures with double crown system
Autorzy:
Dąbrowa, T.
Dobrowolska, A.
Wieleba, W.
Powiązania:
https://bibliotekanauki.pl/articles/306716.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dental crown
friction
prosthodontic materials
korona protetyczna
protetyka stomatologiczna
materiały stomatologiczne
Opis:
Cylindrical telescopic crowns belong to bolt dentures, because their adhesion strength is based on the friction force. The magnitude of static and slide friction forces depends on the strain within the contact area and properties of materials employed. Friction force value between telescope elements declines in the first phase of wearing period and, subsequently, maintains particular constant value of 8 to 10 N. In the telescopic technique, homo and heterogenic joints are used. The following prosthodontic materials have been examined: goldbase alloys (Degudent Kiss, Degulor M), cobalt-base alloy (Brealloy 270), ceramics (Zircon Oxide, Zirconia) during tribological investigations on FGP composite resin. The cooperating surfaces were moistened with synthetic saliva. The research confirmed the dependence of the static friction coefficient on the contact pressure for the analyzed pairs of materials used in prosthodontics. The biggest effect of the contact pressure on the coefficient of friction value occurs when the ceramic rubs on FGP composite resin. The most stable friction coefficient in the context of contact pressure changes as well as life has been found in the case of the cobalt alloy Brealloy 270. An interesting material is a gold alloy Degulor M, for which the coefficient of friction varies only slightly with pressure in the range of 0.6 to 0.9 MPa.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 4; 43-48
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczna protezy szkieletowej podpartej ozębnowo i śluzówkowo
Numerical analysis of static partial denture supported periodontium end gum
Autorzy:
Gralewski, J.
Bogusławski, G.
Powiązania:
https://bibliotekanauki.pl/articles/99203.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza dentystyczna
MES (metoda elementów skończonych)
ANSYS
analiza wytrzymałościowa
model numeryczny
prosthodontics
dental prosthesis
FEM
strength analysis
numerical model
Opis:
W pracy przeprowadzono analizę stanu naprężenia i odkształcenia wybranej konstrukcji protezy szkieletowej oraz reakcji podporowych dla różnych przypadków obciążeń. Uzyskane wyniki obliczeń protezy pozwolą określić sztywność i wytrzymałość konstrukcji, a reakcje podporowe pozwolą wyznaczyć obciążenia zębów filarowych. Analizę przeprowadzono za pomocą metody elementów skończonych w programie ANSYS. Model 3D protezy został stworzony poprzez skanowanie ręcznym skanerem optycznym rzeczywistej protezy szkieletowej gdzie po uzyskaniu chmury punktów został poddany wygładzaniu, stworzono model powierzchniowy a następnie przekonwertowano do postaci bryłowej. Analiza stanu naprężenia i odkształcenia pozwoli uzyskać odpowiedz gdzie występują koncentracje naprężeń w protezie oraz w jaki sposób proteza pod wpływem obciążenia siłami zgryzowymi przenosi siły na zęby oporowe.
The papers deals with the stress and strain analysis for arbitrary chosen construction of denture. The constrain reaction for different load cases was consider. The results of calculation allow to specify stiffness and strength for analysed denture. The obtained reaction allow to define the load subjected the teeth. The ANSYS software based on finite element method was employed for calculation. To create the virtual geometry of denture the opticalscanner was used. From the cloud of points the 3D model of denture geometry was build. In the first step the outer surface of denture was created and then in the second step from the surface the solid model was generated.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 41-46
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza połączenia protetycznego metal - ceramika
The analysis of a structural prosthetic connection ceramics – metal
Autorzy:
Hajduga, M.
Zdziech, T.
Powiązania:
https://bibliotekanauki.pl/articles/98954.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
korona zęba
materiał ceramiczny
materiał metaliczny
prosthodontics
dental crown
ceramic material
metallic material
Opis:
Celem pracy jest analiza struktury połączenia pomiędzy materiałem ceramicznym, a podbudową metaliczną, w zależności od obecności, lub braku warstwy oxydacyjnej na powierzchni metalu. W pracy przedstawiono wyniki analiz charakteru połączenia, które zostały przeprowadzone na jednym stopie metalu i jednym materiale ceramicznym o zróżnicowanym przygotowaniu podłoża zalecanym i nie zalecanym przez producenta. Wyniki badań metalograficznych makrostruktury koron przedstawiono na próbkach za pomocą mikroskopu stereoskopowego w powiększeniach 10x, 200x, 500x. Zmiany stężenia pierwiastków analizowano przy pomocy mikroanalizatora rentgenowskiego Jeol J7, które przeprowadzono na granicy warstw metal-ceramika.
The aim of the work is an analysis of connection structure between a ceramic material and a metallic substructure depending on presence or lack of an oxidised layer on the metal surface and the class of metal treatment by aluminium oxide which were conducted on one metal alloy and one ceramic material with various preparation of a base which was and was not recommended by the producer. Results of metallographic researches of heads macrostructure were recorded on samples for analysis which were gained with the use of a stereoscopic microscope with a magnification of 10x, 200x, 500x. Changes of chemical elements concentration were analyzed by a rentgenographic microanalizer Jeol J7 which was recorded on the border of metal-ceramics layers.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 71-78
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biozgodność stopów protetycznych w funkcji czasu
Biocompatibility of prosthetic alloys as a function of time
Autorzy:
Hajduga, M.
Kalukin, B.
Kalukin, A.
Powiązania:
https://bibliotekanauki.pl/articles/99348.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza dentystyczna
uzupełnienie protetyczne
stop protetyczny
implantacyjna stal austenityczna
biozgodność
prosthodontics
dental prosthesis
prosthetic restoration
prosthetic alloy
implantation austenitic steel
biocompatibility
Opis:
Od przeszło 3000 lat główną grupą materiałów, przeznaczonych do implantacji w organizmie ludzkim są metale i ich stopy. W ostatnim stuleciu najczęściej używana była i jest do dzisiaj implantacyjna stal austenityczna. W ostatnich 30 latach częściowo wyparły ją stopy niklu, kobaltu czy tytanu. Jedną z funkcji, mających wpływ na biozgodność materiału jest czas przebywania konstrukcji w agresywnym środowisku płynów ustrojowych. Autorzy podjęli próbę określenia zakresu zmian w materiałach metalicznych, po długotrwałej implantacji w jamie ustnej. Celem pracy jest określenie wpływu czasu użytkowania na zmianę właściwości materiałowych stopów stomatologicznych. W jej zakresie mieszczą się mikroskopowe badania metalograficzne, mikroanaliza rentgenowska oraz badania mikrotwardości. Wstępna analiza wyników potwierdza tak szerokie rozpowszechnienie implantacyjnej stali austenitycznej.
From 3000 years the majority of materials made for implantation in the human body are metals and alloys. In the last century the most commonly used was steel austenitic implantation. In the past 30 years, it was partly replaced by nickel alloys, cobalt alloys and titanium. One of the functions having the effect on biocompatibility of material is time of construction in aggressive environment, body fluids. The authors undertook an attempt to determine the extent of changes in the metallic materials after long-term implantation in the oral cavity. The aim of this work is to determine the effect of time for a change of using the material used in dental alloys. In this field there are metallographic microscopic examinations, X-ray microanalysis and micro hardness. Preliminary analysis of the results confirms such a wide spread of implantation austenitic steel.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 53-58
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena połączenia metal - ceramika w zależności od sposobu chłodzenia - badania wstępne
The assessment of connection between a metal basis and ceramics depending on the method of cooling - preliminary studies
Autorzy:
Hajduga, M.
Rogalińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/99039.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
proteza dentystyczna
protetyka stomatologiczna
chłodzenie
materiał osłaniający
dental prosthesis
prosthodontics
cooling
casing material
Opis:
Wiodącym tematem pracy jest przedstawienie charakteru połączenia metalowej podbudowy z ceramiką w zależności od sposobu chłodzenia masy osłaniającej. Praca pozwoli określić cechy struktury metalicznej chłodzonej różnymi metodami. Wykonane badania ujawniły wady w strukturze metalicznej - pozwoliły określić charakter połączenia metal-ceramika. Ukonstytuować wstępne wnioski, oceniając, że istotny wpływ na strukturę metaliczną oraz połączenie metal-ceramika ma sposób chłodzenia masy osłaniającej zaraz po odlaniu.
This thesis is to present the nature of connection between a metal basis and ceramics depending on the method of cooling the casing material. This thesis will allow its author to define the features of a metal structure cooled by means of various methods. All performed tests revealed some flaws in the metal structure. They made it possible to define the metal-ceramics connection and draw some preliminary conclusions showing at the same time that what has a great influence on the metal structure and the metal-ceramics connection is the way of cooling the casing material shortly after it has been cast.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 135-140
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Materiały ceramiczne dla protetyki stomatologicznej - właściwości optyczne i mikrostrukturalne wybranych materiałów cyrkonowych
Ceramic materials for dental prosthetics - optical and microstructural properties of zirconia ceramics
Autorzy:
Jaegermann, Z.
Powiązania:
https://bibliotekanauki.pl/articles/168970.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
protetyka stomatologiczna
materiały cyrkonowe
przeświecalność
mikrostruktura
dental prosthetics
zirconia materials
translucency
microstructure
Opis:
Celem badań było wybranie metody oznaczania przeświecalności, porównanie cech optycznych wybranych materiałów cyrkonowych, a także próba określenia zależności przeświecalności od wybranych właściwości fizycznych i cech mikrostrukturalnych materiałów cyrkonowych. Przygotowano i zbadano próbki komercyjnych materiałów cyrkonowych stosowanych w protetyce stomatologicznej w zakresie ich podstawowych właściwości fizycznych i optycznych (gęstość pozorna, barwa, przeświecalność, białość). Ponadto wykonano badania mikroskopowe morfologii porów i ziaren oraz przeprowadzono ocenę zależności przeświecalności od właściwości fizycznych i budowy materiałów cyrkonowych. Scharakteryzowano właściwości optyczne badanych materiałów cyrkonowych i wskazano właściwości, które miały największy wpływ na przeświecalność materiałów.
The aim of the work was to select the method of determine the value of translucency, a comparison of the optical characteristics of the selected zirconia materials, as well as an attempt to determine the relationships between the translucency and selected physical properties and microstructure characteristics of zirconia materials. The samples of commercial zirconia materials used in prosthetic dentistry were prepared and studied their basic physical and optical properties (apparent density, color, translucency, whiteness). Microscopic examination of pores and grain morphology was also performed, as well as translucency dependence on the physical properties and structure of zirconia ceramics was evaluated. In summary, characteristics in terms of the optical properties of the test materials were achieved and properties that, based on the research, had the greatest impact on translucency of materials were indicated.
Źródło:
Szkło i Ceramika; 2013, R. 64, nr 2, 2; 4-13
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of gold with titanium alloy weldability in conditions of a dental technique laboratory
Autorzy:
Jania, G.
Żmudzki, J.
Topolska, S.
Powiązania:
https://bibliotekanauki.pl/articles/24200598.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
titanium alloy
gold
laser welding
prosthetic
implant denture
microstructure
stop tytanu
złoto
spawanie laserowe
protetyka
proteza implantu
mikrostruktura
Opis:
Purpose: In dental practice, there is necessary to weld gold with titanium under the conditions of a dental technique laboratory, which is difficult. The aim was to assess the weldability of pure gold with the titanium alloy Ti6Al4V using a prosthetic laser welding machine. Design/methodology/approach: Gold wire in a diameter of 0.4 mm made with the use of a jewellery drawbar (GOLDPORT, Szczecin, Poland) was welded to a titanium alloy Ti6Al4V substrate of dental implant abutment screw (MegaGen). Dental laser welding parameters (Bego Laser Star T plus) were 230 V; 6.5 ms; 2.5 Hz; laser spot 0.3 mm, and argon blow. Samples were included in resin, ground (500-4000 SiC), polished (Al2O3 suspension) and etched (Kroll solution) per 20 s before observation under a light microscope. Findings: There were well-welded and poorly joined zones. The discontinuities and voids there were not visible or sparse next to the initial weld point. Dendritic structure at well-welded remelting zones and two-phase microstructure of titanium and Ti3Au phase were found. The heat-affected zone was about of 20 microns. Research limitations/implications: Light microscopy was used, and precise phase identification required further investigations. Weld strength assessment requires further micro-hardness and load-bearing ability tests. Weldability concerns the model system with pure gold. Practical implications: In the case of elements with dimensions below 0.4 mm, the use of a laser with a smaller spot should be considered for better control of the remelting zone and mechanical positioning of the elements in order to stabilize and avoid discontinuities and voids. Originality/value: Prosthetic laser welding with a laser spot about of 0.3 mm allows to obtain well-welded parts of 0.3 mm in diameter under stable stitching conditions and higher than 0.4 mm in dimensions.
Źródło:
Archives of Materials Science and Engineering; 2022, 118, 1; 36--41
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies