Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "protetyka" wg kryterium: Temat


Wyświetlanie 1-42 z 42
Tytuł:
What can normal gait biomechanics teach a designer of lower limb prostheses
Autorzy:
Pitkin, M.
Powiązania:
https://bibliotekanauki.pl/articles/306996.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
biomechanics
prosthetics
anthropomorphicity
biomechanika
protetyka
Opis:
Compensating a limb loss with prosthesis is a challenging task due to complexity of the human body which cannot be fully matched by the available technical means. Designer of lower limb prostheses wants to know what specification of the device could provide the best approximation to the normal locomotion. Deep understanding of the latter is essential, and gait analysis may be a valuable tool for this. Once prosthesis is built, gait analysis may help in comparing the wearer’s performance with the new device and with the prior art, and in verification of the hypotheses being put forward during the development process. In this lecture, we will discuss some synergies of normal gait. We will focus on the required biomechanical properties of a prosthetic leg that can allow the prosthesis’s inclusion in normal gait synergy without demanding excessive compensatory movements. We will consider contribution of leg joints to generation of propulsion for adequate design of lower limb prostheses especially those with power supply.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 3-10
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
„Metaloceramika - ukryte wady” czyli problemy protetyki stomatologicznej
The fusing of metal-ceramic and its flaws affecting dental prosthetics
Autorzy:
Rogalińska, A
Hajduga, M.
Powiązania:
https://bibliotekanauki.pl/articles/98826.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
ceramika dentystyczna
metal
wada
prosthodontics
dental ceramics
defect
Opis:
Uzupełnienia protetyczne na podbudowie metalicznej z licowaną ceramiką w obecnej protetyce stomatologicznej są najpopularniejszą i najchętniej wykorzystywaną kombinacją materiałów. Połączenie metal- ceramika zyskało ogromną popularność przy wykonywaniu koron, mostów ze względu nie tylko na walory estetyczne, poprzez ceramikę, ale przede wszystkim dzięki uzyskaniu własności wytrzymałościowych przez wykonanie metalowej podbudowy, osadzonej bezpośrednio na oszlifowane kikuty zębów czy implanty. Połączenie obu materiałów nie zawsze jest idealne. Uzupełnienie często nie wykazują żadnych nieprawidłowości w przypadku obserwacji zewnętrznej. Nie oznacza to, iż w obszarze chemicznego połączenia tych materiałów nie ma swoistych, mikroskopijnych wad. Praca przedstawia typy wad w obszarze styku dwóch różnych faz materiałów protetycznych oraz określa co mogą spowodować.
Metallic porcelain veneered dental restorations are currently the most commonly chosen type of restoration in the dental profession. The use of ceramics fused to metal has gained wide popularity when choosing a material suitable for making dental crowns and bridges not only for aesthetic reasons, but more importantly due to the strength properties of the metallic substructure when placed on the previously grinded dental stump. The process of fusing dental ceramic to the metallic substructure does not always prove to be a success. Metal-ceramic dental restorations do not always exhibit flaws visible to the eye on the outer surface; often the metal-ceramic fusing process creates microscopic flaws. This thesis presents the different kinds of flaws which can occur when bonding two different kinds of prosthetic materials together and the outcome we can expect as a result.
Źródło:
Aktualne Problemy Biomechaniki; 2010, 4; 157-162
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ technologii wytwarzania na właściwości materiałowe stopu kobaltu wykorzystywanego w protetyce dentystycznej
The effects of production technology on cobalt alloy material properties used in dental techniques
Autorzy:
Litwinko, M.
Grądzka-Dahlke, M.
Powiązania:
https://bibliotekanauki.pl/articles/99335.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
stop kobaltu
protetyka dentystyczna
odlewnictwo
SLM
cobalt alloy
prosthetic dentistry
foundry
Opis:
Jednym z etapów w procesie powstawania protetycznego uzupełnienia dentystycznego jest realizacja zaprojektowanego kształtu protezy w tworzywie metalowym. Jest krokiem istotnym a zarazem narażonym na wiele niepowodzeń. W artykule przedstawiono porównanie dwóch metod wykonawstwa techniki dentystycznej: tradycyjnego odlewania oraz nowoczesnej SLM. Badaniom poddano protetyczny stop kobaltu w postaci prostopadłościennych próbek.
One of the stages in the process of restoration of dental prostheses is the shape which was designed to achieve a complement in the metal. It is an important step and exposed to many setbacks. The article gives a comparison of two methods of dental technology: traditional casting and modern SLM. The test was in the form of a cobalt alloy prosthetic square bales samples.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 99-102
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of friction in the mechanism of retaining the partial removable dentures with double crown system
Autorzy:
Dąbrowa, T.
Dobrowolska, A.
Wieleba, W.
Powiązania:
https://bibliotekanauki.pl/articles/306716.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dental crown
friction
prosthodontic materials
korona protetyczna
protetyka stomatologiczna
materiały stomatologiczne
Opis:
Cylindrical telescopic crowns belong to bolt dentures, because their adhesion strength is based on the friction force. The magnitude of static and slide friction forces depends on the strain within the contact area and properties of materials employed. Friction force value between telescope elements declines in the first phase of wearing period and, subsequently, maintains particular constant value of 8 to 10 N. In the telescopic technique, homo and heterogenic joints are used. The following prosthodontic materials have been examined: goldbase alloys (Degudent Kiss, Degulor M), cobalt-base alloy (Brealloy 270), ceramics (Zircon Oxide, Zirconia) during tribological investigations on FGP composite resin. The cooperating surfaces were moistened with synthetic saliva. The research confirmed the dependence of the static friction coefficient on the contact pressure for the analyzed pairs of materials used in prosthodontics. The biggest effect of the contact pressure on the coefficient of friction value occurs when the ceramic rubs on FGP composite resin. The most stable friction coefficient in the context of contact pressure changes as well as life has been found in the case of the cobalt alloy Brealloy 270. An interesting material is a gold alloy Degulor M, for which the coefficient of friction varies only slightly with pressure in the range of 0.6 to 0.9 MPa.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 4; 43-48
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Materiały ceramiczne dla protetyki stomatologicznej - właściwości optyczne i mikrostrukturalne wybranych materiałów cyrkonowych
Ceramic materials for dental prosthetics - optical and microstructural properties of zirconia ceramics
Autorzy:
Jaegermann, Z.
Powiązania:
https://bibliotekanauki.pl/articles/168970.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
protetyka stomatologiczna
materiały cyrkonowe
przeświecalność
mikrostruktura
dental prosthetics
zirconia materials
translucency
microstructure
Opis:
Celem badań było wybranie metody oznaczania przeświecalności, porównanie cech optycznych wybranych materiałów cyrkonowych, a także próba określenia zależności przeświecalności od wybranych właściwości fizycznych i cech mikrostrukturalnych materiałów cyrkonowych. Przygotowano i zbadano próbki komercyjnych materiałów cyrkonowych stosowanych w protetyce stomatologicznej w zakresie ich podstawowych właściwości fizycznych i optycznych (gęstość pozorna, barwa, przeświecalność, białość). Ponadto wykonano badania mikroskopowe morfologii porów i ziaren oraz przeprowadzono ocenę zależności przeświecalności od właściwości fizycznych i budowy materiałów cyrkonowych. Scharakteryzowano właściwości optyczne badanych materiałów cyrkonowych i wskazano właściwości, które miały największy wpływ na przeświecalność materiałów.
The aim of the work was to select the method of determine the value of translucency, a comparison of the optical characteristics of the selected zirconia materials, as well as an attempt to determine the relationships between the translucency and selected physical properties and microstructure characteristics of zirconia materials. The samples of commercial zirconia materials used in prosthetic dentistry were prepared and studied their basic physical and optical properties (apparent density, color, translucency, whiteness). Microscopic examination of pores and grain morphology was also performed, as well as translucency dependence on the physical properties and structure of zirconia ceramics was evaluated. In summary, characteristics in terms of the optical properties of the test materials were achieved and properties that, based on the research, had the greatest impact on translucency of materials were indicated.
Źródło:
Szkło i Ceramika; 2013, R. 64, nr 2, 2; 4-13
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura i własności mechaniczne modyfikowanych stopów CoCrMo do zastosowań w protetyce stomatologicznej
Structure and mechanical properties of modified CoCrMo alloys for use in dental prosthetics
Autorzy:
Beer, K.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/285534.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
protetyka stomatologiczna
biomateriały
stopy CoCrMo
dental prosthetics
biomaterials
Co-Cr-Mo alloys
Opis:
Większość klinicznych niepowodzeń w przypadku protez stomatologicznych związana jest przede wszystkim z techniką wytapiania i odlewania oraz ilością użytego do wsadu stopu już raz przetopionego. W pracy dokonano analizy wpływu ilości materiału z recyklingu na właściwości mechaniczne i strukturę stomatologicznego stopu CoCrMo. Zastosowano metodę odlewania odśrodkowego, oraz jednokrotne przetopy o składzie wyjściowym odpowiednio 0, 25, 50, 75 i 100% złomu. Przeprowadzono statyczną próbę rozciągania, pomiar mikrotwardości, analizę mikrostrukturalną oraz obserwację SEM przełomów. Stwierdzono, że własności mechaniczne wszystkich przetapianych stopów są gorsze niż stopu czystego, zakupionego u zagranicznego producenta. Mikrostruktura przełomów przetapianych stopów z zawartością złomu powyżej 50% jest bardziej niejednorodna i w strukturze dendrytycznej widoczna jest większa ilość mikropęknięć. Podczas zrywania próbek zarejestrowano wyraźne obniżenie granicy plastyczności i wytrzymałości tych stopów w próbach zrywania w porównaniu z próbkami ze stopów zawierających mniejszą ilość materiału z recyklingu.
The majority of clinical failures in the case of dental prostheses is associated primarily with the technique and the amount of remelted alloy used for the casting. The majority of clinical failures in the case of dental prostheses is associated primarily with the technique of remelting and casting, and quantity of the once remelted alloy used for the batch. The paper analyzes the impact of the amounts of recycled material on the mechanical properties and structure of dental alloy CoCrMo. The centrifugal casting method has been applied and remelted alloys with output composition of 0, 25, 50, 75 and 100% of scrap respectively. The static tensile test, microstructural analysis and SEM observation as well as microhardness test have been conducted. These all tests show that the mechanical strength of all remelted alloys is worse than the strength of the fine alloy, purchased from a foreign manufacturer. The microstructure of breakthroughs of the remelted alloys containing more than 50% of scrap is more heterogeneous and a higher amount of microcracks is visible in the dendritic structure. When the samples were tested in the static tension test, the significant decrease in the yield strength and the tensile strength of these alloys during these static tension tests in comparison to the samples of alloys containing lower amount of the recycled material were observed.
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 110-115
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena połączenia metal - ceramika w zależności od sposobu chłodzenia - badania wstępne
The assessment of connection between a metal basis and ceramics depending on the method of cooling - preliminary studies
Autorzy:
Hajduga, M.
Rogalińska, A.
Powiązania:
https://bibliotekanauki.pl/articles/99039.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
proteza dentystyczna
protetyka stomatologiczna
chłodzenie
materiał osłaniający
dental prosthesis
prosthodontics
cooling
casing material
Opis:
Wiodącym tematem pracy jest przedstawienie charakteru połączenia metalowej podbudowy z ceramiką w zależności od sposobu chłodzenia masy osłaniającej. Praca pozwoli określić cechy struktury metalicznej chłodzonej różnymi metodami. Wykonane badania ujawniły wady w strukturze metalicznej - pozwoliły określić charakter połączenia metal-ceramika. Ukonstytuować wstępne wnioski, oceniając, że istotny wpływ na strukturę metaliczną oraz połączenie metal-ceramika ma sposób chłodzenia masy osłaniającej zaraz po odlaniu.
This thesis is to present the nature of connection between a metal basis and ceramics depending on the method of cooling the casing material. This thesis will allow its author to define the features of a metal structure cooled by means of various methods. All performed tests revealed some flaws in the metal structure. They made it possible to define the metal-ceramics connection and draw some preliminary conclusions showing at the same time that what has a great influence on the metal structure and the metal-ceramics connection is the way of cooling the casing material shortly after it has been cast.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 135-140
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Znaczenie warunków podparcia i obciążenia w modelowych badaniach MES protez zębowych typu overdenture
Importance of support and loading conditions in overdenture FEM model investigations
Autorzy:
Żmudzki, J.
Chladek, G.
Powiązania:
https://bibliotekanauki.pl/articles/98749.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza zębowa
MES (metoda elementów skończonych)
żucie
prosthodontics
dental prosthesis
FEM
mastication
Opis:
W badaniach modelowych FEM protez overdenture założenie więzów ograniczających ruchomość protezy w sposób zgodny z zasadami ich funkcjonowania pozwala na rozpoznanie obciążeń złączy, przy znacznym uproszczeniu modelu numerycznego. Dla powszechnie dostępnych w sprzedaży typów złączy podczas transmisji sił żucia stwierdzono występowanie znacznych wartości obciążeń bocznych, co stanowi bezpośrednie wyjaśnienie przyczyn niepowodzeń mechanicznych. Założenie pionowych kierunków sił zgryzowych prowadzi do znacznego niedoszacowania obciążeń złączy.
In overdenture FEM analysis, assumption of constrains reducing denture movement according to the rules of their functioning allows to determine loads of attachments, at the same time significantly simplifying numerical model. For commonly available types of attachments - during occlusal forces transmission found has been an occurrence of considerable lateral loads, which directly explains the causes of mechanical failures. Assumption of vertical occlusal forces directions leads to remarkable underestimating of attachments loads.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 239-245
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakter struktury połączenia porcelany na podbudowie cyrkonowej w zależności od gatunku materiału licującego
Type of join structure between porcelain and zirconium oxide base, depending on kind of porcelain
Autorzy:
Legutko, A.
Hajduga, M.
Powiązania:
https://bibliotekanauki.pl/articles/98856.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
ceramika dentystyczna
protetyka stomatologiczna
tlenek cyrkonu
porcelana
Cercon
dental ceramics
prosthodontics
zirconium oxide
porcelain
Opis:
W branży techniki dentystycznej pojawiła się nowa technologia CAD/CAM wykonawstwa pełnoceramicznych koron i mostów. Na rynku materiałów dla techniki dentystycznej dostępnych jest kilkanaście systemów pełnoceramicznych oferujących materiały do wykonania ceramicznej podbudowy i licowania. System Cercon Smart Ceramics firmy DeguDent składa się z ceramiki cyrkonowej przeznaczonej na podbudowy i porcelany skaleniowej stosowanej do licowania tych podbudów. W pracy przedstawiono charakter struktury połączenia tych materiałów, a także sprawdzono czy porcelana innego producenta może być stosowana zamiennie z porcelaną zalecaną w systemie Cercon.
The purpose of thesis is characterizing connection between cercon base materials and covering porcelain and checking which forces (mechanical or chemical) are responsible too linkage materials. At the second part of thesis is described preparation samples of materials to research. Executed observations on optical microscope Zeiss M1m Imager and scanning electron microscope FEI E-SEM XL30 with X EDAX GEMINI 4000. Got results of qualitative and quantitative analyses which have showed character of materials connection. Researched materials Cercon Base, Cercon Ceram Kiss and Lava Ceram are compatible for each other.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 121-126
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowa analiza MES wpływu silikonów podścielających protezy zębowe na redystrybucję obciążeń w tkankach miękkich podłoża protetycznego
FEM model analysis of dentures silicon relining influence on the stresses redistribution in denture foundation soft tissues
Autorzy:
Żmudzki, J.
Powiązania:
https://bibliotekanauki.pl/articles/99337.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza zębowa
MES (metoda elementów skończonych)
uraz
prosthodontics
dental prosthesis
FEM
injury
Opis:
Urazy i odczucia dyskomfortu bólowego podczas użytkowania protez zębowych mogą powstawać w wyniku przekroczenia tolerancji tkanki zarówno na ciśnienie jak i ścinanie, których maksymalne wartości na drodze badań MES zlokalizowano we wzajemnie odległych obszarach. Wprowadzenie silikonowego podścielenia protezy skutkuje zmniejszeniem maksymalnych wartości nacisków i ich wyrównaniem na powierzchni przylegania. Jednak przeniesienie części nacisków na stoki bezzębnych wyrostków skutkuje zwiększeniem ścinania przy kości pod powierzchnią tkanki miękkiej.
Injuries and discomfort of pain sensations during wearing of dentures might result from exceeding tissue tolerances both as far as pressure and shear are concerned. Their maximum values determined by means of FEM analysis were located in opposite areas. Introducing silicone denture relining results in reduction of maximum compression values and their balance on adherence interface. Nevertheless, relocation of part of the compression forces on slopes of edentulous ridges causes increase of shear at the bone under surface of soft tissues.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 233-238
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stabilności termicznej proszków ZrO2 modyfikowanych tlenkami MgO oraz Y2O3
Evaluation of thermal stability of ZrO2 powders modified with MgO and Y2O3
Autorzy:
Nakonieczny, D.
Paszenda, Z.
Walke, W.
Powiązania:
https://bibliotekanauki.pl/articles/285514.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
zol-żel
biomateriały ceramiczne
protetyka stomatologiczna
CAD/CAM
sol-gel
ceramic biomaterials
prosthetic dentistry
Opis:
Celem zrealizowanych badań było uzyskanie proszków ZrO2 zmodyfikowanych tlenkami itru i magnezu, które mogłyby być wykorzystane do przygotowania bloczków ceramicznych - półproduktu w procesie wytwarzania tzw. pełnoceramicznych protez stałych w protetyce stomatologicznej. Uzupełnienia pełnoceramiczne (full-ceramic restorations) w porównaniu do konwencjonalnych protez metalowo-ceramicznych (porcelain fused to metal) nie powodują metalozy oraz nie sprzyjają odkładaniu się płytki nazębnej i kamienia nazębnego. Rosnąca popularność protez pełnoceramicznych jest wynikiem upowszechnienia się technologii CAD/CAM, (wprowadzenie bardzo dokładnych frezarek numerycznych oraz oprogramowania dedykowanego dla gabinetów i laboratoriów stomatologicznych), dzięki której można precyzyjnie odwzorować warunki anatomiczne panujące w jamie ustnej pacjenta oraz wykonać funkcjonale uzupełnia protetyczne. Etapem limitującym dalsze stadia procesu wytwórczego oraz właściwości eksploatacyjne ZrO2 jest synteza proszków ceramicznych. Do przygotowania proszków wykorzystano „klasyczną” mokrą metodę zol-żel. Jako prekursor tlenku cyrkonu zastosowano propanolan cyrkonu. Jako prekursory domieszek tlenkowych wykorzystano heksahydraty azotanu itru oraz magnezu. Przydatność przygotowanych do prac proszków oceniono na podstawie analizy termicznej z wykorzystaniem termograwimetrii (TG). Materiały poddano badaniom ze względu na prawdopodobieństwo wystąpienia w składzie chemicznym sporządzonych próbek termolabilnego w zakresie temperatur spiekania wodorotlenku cyrkonu (Zr(OH)4, temperatura rozkładu 823 K) [1]. Przeprowadzona analiza pozwoliła stwierdzić nieznaczny, nie związany z dehydratacją ubytek masy próbek, co świadczy o braku obecności wodorotlenku cyrkonu w przygotowanych proszkach.
The aim of presented study was to obtain zirconia powders modified with magnesium and yttrium oxides addition, which could be used for the preparation of the ceramic blocks - an intermediate product for manufacturing of the full ceramic fixed prosthetic restorations in prosthetic dentistry. Full ceramic restorations compared to so called conventional porcelain fused to metal restorations do not cause metallosis and prevent to the accumulation of plaque and tartar. The growing popularity of all-ceramic restorations is the result of spread of CAD / CAM technology, (introduction of high-precision milling machines and dedicated software for dentist and technicians la¬boratories) which allows to precisely reproduce the anatomical conditions prevailing in the patient's mouth and perform functional prosthetic restorations. Limiting step of the further process stages is the synthesis of ceramic powders. For the preparation of the ceramic powders the "classic" wet sol-gel method was used. As the zirconium oxide precursor zirconium isopropoxide was used. As the dopant oxide precursors were used yttrium and magnesium nitrate hexahydrates. Usefulness of prepared powders was characterized by thermogravimetry (TG). Materials were tested due to the likelihood occurrence of zirconium hydroxide in prepared samples chemical composition which is thermolabile in the range of sintering temperatures (Zr(OH)4, decomposition temperature 823 K) [1]. Results of the analysis led to the conclusion of presence of negligible, not associated with dehydration weight loss of the samples which show the absence of zirconium hydroxide in prepared powders.
Źródło:
Engineering of Biomaterials; 2013, 16, 120; 8-12
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmiana stężeń pierwiastków na granicy połączenia metal - ceramika w uzupełnieniu protetycznym
The change in elements construction an border of connection between a metal basis and ceramics in the prosthetic restoration
Autorzy:
Rogalińska, A.
Hajduga, M.
Powiązania:
https://bibliotekanauki.pl/articles/98686.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza dentystyczna
uzupełnienie protetyczne
korona zęba
prosthodontics
dental prosthesis
prosthetic restoration
dental crown
Opis:
Temat pracy obejmuje ocenę charakteru połączenia metal- ceramika w konstrukcji protetycznej korony złożonej, licowanej ceramiką na podbudowie metalicznej. Praca określa cechy struktury metalicznej, którą bezpośrednio po odlaniu w masie osłaniającej chłodzono w bieżącej wodzie o temp. 15 °C. Wykonane badania ujawniły wady w strukturze metalicznej, zmianę stężeń pierwiastków, skład w poszczególnych miejscach próbki (w warstwie ceramicznej, metalicznej i na granicy połączenia metal-ceramika), przedstawiły obraz struktury i identyfikację składników strukturalnych oraz pozwoliły określić charakter połączenia pomiędzy dwoma fazami, tworzącymi uzupełnienie protetyczne.
The topic of the thesis includes the estimation of combination metal with ceramics in denture prosthesis crown, harmonized with ceramics on metal base. The thesis determines features of metal structure which directly after the casting in screnning substance cooled in running water. The research shown failures in metal structure, the change in elements construction, composition in particular places of the sample ( in ceramic and metal layer and on the boundry between them) shown the image of its structure and identification of structural ingredients and allowed to determine the combination between two phases creating the prosthetic restoration.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 193-200
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nylon jako tworzywo termoplastyczne używane w protetyce dentystycznej
Nylon as thermoplastic material prosthetics used in dental
Autorzy:
Mróz, M.
Hajduga, M.
Powiązania:
https://bibliotekanauki.pl/articles/98862.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
nylon
tworzywo termoplastyczne
twardość
nasiąkliwość
właściwości strukturalne
prosthodontics
thermoplastic material
hardness
absorption
structural properties
Opis:
W pracy zestawiono właściwości strukturalne termoplastycznych materiałów nylonowych. Pierwszym etapem badań było wykonanie dokładnej identyfikacji materiału. Następnie przeprowadzono badania twardości oraz nasiąkliwości. Ponadto wykonano zdjęcia strukturalne za pomocą mikroskopu świetlnego oraz zdjęcia faktograficzne za pomocą mikroskopu stereoskopowego. Celem pracy było porównanie właściwości strukturalnych oraz ocena warstwy wierzchniej tychże materiałów.
The work contains a comparison of structural properties of elastic nylon materials. The first stage of research was to make a detailed material identification. Next the hardness and absorbability tests were carried. Moreover , with the aid of light microscope structural photographs were taken as well as factographical pictures with the aid of stereoscopic microscope we taken. The aim of the thesis was to compare the structural properties and assessment of external layer of these materials.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 167-172
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niskotemperaturowe starzenie cyrkonowych materiałów ceramicznych Y-tzp. Cz. 2. Wstępne badania procesu z wykorzystaniem techniki EBSD
Low-temperature degradation of Y-TZP zirconia ceramics. Part 2: Preliminary EBSD study
Autorzy:
Tymowicz-Grzyb, P.
Jaegermann, Z.
Powiązania:
https://bibliotekanauki.pl/articles/168873.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
protetyka stomatologiczna
ceramika cyrkonowa
starzenie niskotemperaturowe
XRD
SEM
EBSD
dental prosthetics
zirconia ceramics
low-temperature degradation
Opis:
W publikacji przedstawiono wyniki badania zjawiska starzenia niskotemperaturowego materiałów cyrkonowych metodą opartą na dyfrakcji elektronów wstecznie rozproszonych EBSD (ang. Elektron Backscattered Diffraction). Celem pracy była próba odpowiedzi na pytanie czy metoda EBSD może służyć do zidentyfikowania początkowych etapów procesu niskotemperaturowego starzenia materiałów cyrkonowych Y-TZP. Do celów porównawczych wykorzystano wcześniejsze wyniki badań procesu starzenia prowadzone metodami XRD i obserwacji SEM, opublikowane w części 1 artykułu. Analiza wyników przeprowadzonych badań pokazała, że czułość metody EBSD w wykrywaniu wczesnych zmian transformacji t→m jest znacznie wyższa niż metod XRD i SEM. Analiza obrazów dyfrakcyjnych uzyskanych metodą EBSD wykazała obecność fazy jednoskośnej w powierzchniowych warstwach materiałów pomimo tego, że nie wykazały jej badania dyfrakcyjne XRD.
The results of EBSD (Elektron Backscattered Diffraction) study on the low-temperature degradation (LTD) phenomenon of zirconia materials were presented. The aim of the study was to answer the question whether the EBSD method can be used to identify the initial LTD stages of Y-TZP zirconia. For comparative purposes, previous results on XRD study and SEM observation, published in part 1 of the article, was used. The results of the studies have shown that the sensitivity of EBSD method for detecting early stages of t→m transformation is significantly higher than that of XRD and SEM. Analysis of EBSD diffraction patterns revealed the presence of monoclinic phase in the superficial layers of materials despite the fact that the diffraction patterns did not show it.
Źródło:
Szkło i Ceramika; 2017, R. 68, nr 5, 5; 14-18
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural and Micromechanical Tests of Titanium Crowns
Badania mikrostrukturalne i mikromechaniczne koron tytanowych
Autorzy:
Ryniewicz, Wojciech
Bojko, Łukasz
Pałka, Paweł
Osada, Piotr
Ryniewicz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2200622.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prosthetics
titanium alloy
fixed structure
digital technology
biomechanics
protetyka
stop tytanu
konstrukcja stała
technologia cyfrowa
biomechanika
Opis:
Fixed prosthetic restorations must meet the health requirements in terms of the protection of the tissues of the oral cavity, biomechanical requirements for optimal tissue stress and the strength and wear resistance of the structure, aesthetic requirements related to the location of the gingival margin, as well as the shape, thickness, and colour of the veneers. The aim is to evaluate the impact of manufacturing technology on the microstructure and micromechanical parameters of titanium crowns. The material of the analysis are prosthetic crowns made of Ti6Al4V alloy for the maxilla premolars and the mandible molars, produced using two technologies: Selective Laser Melting (SLM) and CAD/CAM milling. Crown structures were evaluated on the basis of examinations of the microstructure and surface layer of the chamfers, micromechanical parameters in axial sections perpendicular to the dental arches, and the accuracy of mapping the internal shape in sections with horizontal planes perpendicular to the axis of the abutment tooth. The results of this work can be used in a clinical setting. They allow the evaluation of what is the impact of the technology of producing the supporting substructure on the structure of the prosthetic crown. The strength requirements in both technologies are met, while the higher value of the microhardness of the titanium SLM substructure, compared to the milled one, increases the stiffness of the structure under conditions of biomechanical excitation. The errors in mapping the internal shape of the crowns are comparable and slightly higher during sintering.
Stałe uzupełnienia protetyczne powinny spełniać wymagania zdrowotne w aspekcie zabezpieczenia tkanek jamy ustnej, wymagania biomechaniczne dotyczące optymalnego wytężenia tkanek oraz wytrzymałości i odporności na zużycie konstrukcji, wymagania estetyczne związane z usytuowaniem obrzeża dodziąsłowego, a także kształtem, grubością i kolorem licowania. Celem jest ocena wpływu technologii wytwarzania na mikrostrukturę i parametry mikromechaniczne koron tytanowych. Materiałem analizy są korony protetyczne ze stopu Ti6Al4V na zęby przedtrzonowe szczęki i trzonowe żuchwy wytwarzane dwoma technologiami: Selective Laser Melting (SLM) i frezowania CAD/CAM. Konstrukcje koron oceniano na podstawie badań mikrostruktury i warstwy wierzchniej stopni, parametrów mikromechanicznych w osiowych przekrojach prostopadłych do łuków zębowych oraz dokładności odwzorowania kształtu wewnętrznego w przekrojach płaszczyznami horyzontalnymi, prostopadłymi do osi zęba filarowego. Wyniki tej pracy mogą być wykorzystane w warunkach klinicznych. Pozwalają ocenić, jaki jest wpływ technologii wytworzenia podbudowy nośnej, na konstrukcję korony protetycznej. Wymagania wytrzymałościowe w obu technologiach są spełnione, przy czym wyższa wartość mikrotwardości podbudowy tytanowej z SLM, w porównaniu do frezowanej, wpływa na zwiększenie sztywności konstrukcji w warunkach wymuszeń biomechanicznych. Błędy odwzorowania kształtu wewnętrznego koron są porównywalne i nieco wyższe przy spiekaniu.
Źródło:
Tribologia; 2022, 4; 61--72
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innowacyjne procesy druku 3D – analiza ryzyka wdrożenia innowacji w branży stomatologicznej
Autorzy:
Klimecka-Tatar, D.
Kapustka, K.
Powiązania:
https://bibliotekanauki.pl/articles/114772.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
innowacje
druk 3D
stomatologia
protetyka
analiza SWOT
stomatology
prosthetics
3D printing
SWOT analysis
Opis:
Branża medyczna jest oceniana jako jedna z bardziej nowoczesnych dziedzin gospodarki wymagających stosowania zaawansowanych technologii. Jednocześnie spełnienia wysokich oczekiwań społecznych dotyczących wprowadzania na rynek nowych sposób poprawiania stanu zdrowia pacjentów. Obecnie obserwuje się ciągły postęp w dziedzinie druku 3D, a możliwości aplikacyjne w przyszłości stworzą bardzo wartościowy rynek. Artykuł przedstawia analizę branży stomatologicznej, implementację nowoczesnego rozwiązania – druku 3D w wybranej klinice stomatologicznej, zapoznanie z systemami pracy drukarek 3D, macierz BCG do oceny możliwości rynkowych oraz przedsiębiorstwa, rozbudowaną analizę otoczenia SWOT oraz TOWS, kalkulację ceny produktu.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2016, 1 (4); 92-106
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza połączenia protetycznego metal - ceramika
The analysis of a structural prosthetic connection ceramics – metal
Autorzy:
Hajduga, M.
Zdziech, T.
Powiązania:
https://bibliotekanauki.pl/articles/98954.pdf
Data publikacji:
2008
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
korona zęba
materiał ceramiczny
materiał metaliczny
prosthodontics
dental crown
ceramic material
metallic material
Opis:
Celem pracy jest analiza struktury połączenia pomiędzy materiałem ceramicznym, a podbudową metaliczną, w zależności od obecności, lub braku warstwy oxydacyjnej na powierzchni metalu. W pracy przedstawiono wyniki analiz charakteru połączenia, które zostały przeprowadzone na jednym stopie metalu i jednym materiale ceramicznym o zróżnicowanym przygotowaniu podłoża zalecanym i nie zalecanym przez producenta. Wyniki badań metalograficznych makrostruktury koron przedstawiono na próbkach za pomocą mikroskopu stereoskopowego w powiększeniach 10x, 200x, 500x. Zmiany stężenia pierwiastków analizowano przy pomocy mikroanalizatora rentgenowskiego Jeol J7, które przeprowadzono na granicy warstw metal-ceramika.
The aim of the work is an analysis of connection structure between a ceramic material and a metallic substructure depending on presence or lack of an oxidised layer on the metal surface and the class of metal treatment by aluminium oxide which were conducted on one metal alloy and one ceramic material with various preparation of a base which was and was not recommended by the producer. Results of metallographic researches of heads macrostructure were recorded on samples for analysis which were gained with the use of a stereoscopic microscope with a magnification of 10x, 200x, 500x. Changes of chemical elements concentration were analyzed by a rentgenographic microanalizer Jeol J7 which was recorded on the border of metal-ceramics layers.
Źródło:
Aktualne Problemy Biomechaniki; 2008, 2; 71-78
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Remelting on the Quality of Prosthetic Cobalt Alloys
Autorzy:
Nadolski, M.
Łągiewka, M.
Konopka, Z.
Zyska, A.
Golański, G.
Powiązania:
https://bibliotekanauki.pl/articles/382647.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt alloy
centrifugal casting
lost wax technology
dental prosthetics
stop kobaltu
odlewanie odśrodkowe
metoda wytapianych modeli
protetyka stomatologiczna
Opis:
A commercial cobalt alloy applied in dental prosthetics was investigated. The scope of the work included the microstructure analysis, performance examination (tensile strength, microhardness, corrosion resistance), and dilatometric examination. The investigated alloy after a single remelting was characterised by higher tensile strength and hardness. There were not found the definite results with regard to the corrosion resistance of the examined materials. No significant change occurred in the coefficient of thermal expansion.
Źródło:
Archives of Foundry Engineering; 2015, 15, 3 spec.; 53-58
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Materiały ceramiczne dla protetyki stomatologicznej – ceramiczne bloki cyrkonowe z gradientem barwy
Ceramic materials for dental prosthetics – color gradient zirconia blocks
Autorzy:
Wiśniewski, Z.
Jaegermann, Z.
Michałowski, S.
Michalik, R.
Powiązania:
https://bibliotekanauki.pl/articles/168733.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
protetyka stomatologiczna
CAD/CAM
bloki cyrkonowe
skala VITA
gradient barwy
dental prosthetics
zirconia blocks
VITA scale
color gradient
Opis:
Ostatnie lata charakteryzuje intensywny rozwój stomatologii estetycznej. Jednym z ważnych aspektów estetycznej odbudowy koron zębowych jest odpowiednie dobranie odcienia sztucznej korony do naturalnej barwy zęba. Stąd celem badań było opracowanie sposobu formowania bloków cyrkonowych z gradientową zmianą barwy. Do badań użyto granulatów barwionych w odcieniach A1, A2, A3 i A3,5 skali barw VITA, z których – metodą prasowania – formowano gradientowe próbki badawcze. Oceniono ich właściwości fizyczne, strukturę rozkładu barwy i nasycenia, oceny dokonali również specjaliści z firmy protetycznej. Wyniki przeprowadzonych badań i prób eksperymentalnych wykazały, że zaproponowana metoda pozwala na otrzymywanie bloków cyrkonowych z gradientem barwy, co znacznie uprości dotychczas stosowane metody barwienia i licowania uzupełnień protetycznych. Doświadczenie zdobyte przy pracach opisanych w przedstawionym opracowaniu, pozwoli w łatwy sposób na zastosowanie tej metody do innych par granulatów z poszczególnych grup kolorystycznych skali barw VITA.
In the past years there has been an intensive development of cosmetic dentistry. The appropriate selection of artificial crown shade corresponding to the natural teeth color is one of the most important aspects of aesthetic reconstruction of dental crowns. Hence the purpose of the work described was to develop a method for manufacturing zirconia blocks characterized by gradient color change. Colored ready-topress powders in shades of A1, A2, A3 and A3.5 of VITA color scale were used and gradient test samples were formed by pressing. Their physical properties, structure, color and saturation distribution were evaluated. Overall assessment of the usefulness was performed by specialists from prosthetic company. The results of the research and experimental tests have shown that the proposed method allows to obtain zirconia blocks with a color gradient, which can simplify the currently used methods of staining and veneering of prosthetic restorations. It seems possible to replace the time-consuming and difficult veneering by only painting techniques. Experience gained from the study described in the present article will allow to apply this method to the other VITA color scale ready-to-press powders.
Źródło:
Szkło i Ceramika; 2015, R. 66, nr 4, 4; 13-16
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of magnesia-doped yttria-stabilized zirconia powders for dental technology applications
Autorzy:
Nakonieczny, D.
Walke, W.
Majewska, J.
Paszenda, Z.
Powiązania:
https://bibliotekanauki.pl/articles/307056.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
stomatologia
protetyka
materiały protetyczne
metoda zol-żel
full ceramic restorations
prosthetic dentistry
sol-gel method
Zirconium Oxide
Opis:
Purpose: This paper is focused on the works concerning on preparing zirconium oxide ceramic blocks recommended for CAD/CAM systems used in prosthetic dentistry for manufacturing fixed prosthetic restorations. Methods: Zirconium-yttrium-magnesium mixed ceramic oxides were prepared by sol-gel method via hydrolysis and condensation of zirconium alkoxide precursor (zirconium (IV) propoxide) with yttrium and magnesium nitrates diluted in 2-propanol. The aim of this work it was to obtain 2% mol yttria stabilized zirconia ceramic powders with magnesium as an additional tetragonal ZrO2 phase stabilizer in amount between 2÷6% mol (with 2% variable). Prepared gels were dried (24 h in 65°C). Obtained powders were mixed with binder (carboxymethyl cellulose) and uniaxial pressed in to a specimens with diameter 38 x 22 x 6 mm. Afterwards green bodies were sintered in range of temperature between 1350-1550°C. Powders and blocks were characterized by Scanning Electron Microscopy, Fourier Transform Infrared Spectroscopy, Specific Area Measurement. Results: Highly homogeneous powders with a low open porosity, was obtained. Prepared blocks after sintering showed numerous cracks. Nevertheless blocks was fine grained and show quite reproducible chemical composition. Conclusion: A sol gel wet chemical route of powder synthesis allow to obtain high homogenous ceramic materials with inconsiderable amount of pores with low variation in a diameter. In spite of a reproducible synthesis methods of a ceramic powders, applied to prepare green bodies procedure and sintering manner do not allowed to obtain free from cracks zirconia ceramics blocks.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 4; 99-106
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of finite element method for the analysis of a prefabricated post-and-core – tooth system
Autorzy:
Loska, S.
Paszenda, Z.
Basiaga, M.
Kiel-Jamrozik, M.
Powiązania:
https://bibliotekanauki.pl/articles/115584.pdf
Data publikacji:
2015
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
prefabricated posts
prosthetic reconstructions
finite element analysis
korona protetyczna
rekonstrukcja protetyczna
analiza metodą elementów skończonych
protetyka stomatologiczna
Opis:
In recent years in the area of prosthetic treatment, great emphasise was put on leaving a residual dentition inside mouth. In a teeth after endodontic treatment or with broken crown a healthy root is a natural implant that can be used for further reconstruction. Use of posts-and-cores is one of possible methods of widely damaged tooth crowns treatment. There is a lot of different types of prefabricated posts-and-cores. Numerical analysis of the prefabricated post-and-core – tooth system was conducted by the authors. The prefabricated Flexi-Flange post-and-core from the Essential Dental System was selected for the analysis. The scope of the analysis has covered calculation of displacements, strains and stresses in each elements of the analysed system – depending on the applied post material and load applied on the prosthetic crown. The analysis reviled that there is a significant influence of the type of the post material and load on results. It was found that the most unfavourable variant of load is the one with force applied on the labial surface at the angle of 45° to the axis of the tooth. The results of the analysed system provided a valuable guidelines for proper design of its form, geometrical properties, selection of the mechanical properties and the optimal strengthening degree of metallic biomaterial.
Źródło:
Challenges of Modern Technology; 2015, 6, 1; 11-22
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of saliva and its substitutes on corrosion of some implant alloys
Autorzy:
Andrysewicz, E.
Powiązania:
https://bibliotekanauki.pl/articles/387260.pdf
Data publikacji:
2013
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
metallic alloys
corosion
human saliva
saliva substitute
prosthodontia
stopy metalu
korozja
ludzka ślina
substytut śliny
protetyka stomatologiczna
Opis:
The purpose of this paper is evaluation of the influence of human saliva and its substitutes on the corrosion re sistance of some implant alloys used in stomatology, which included: austenitic steel (316L), titanium alloy (Ti6Al4V), and cobalt alloy (CoCrMo). Corrosion studies were conducted by means of the potentiodynamic method with the application of the VoltaLab 21 kit with VoltaMaster 4 software. The reference electrode was a saturated calomel electrode (SCE), whereas the counter electrode was a platinum electrode. The results of conducted studies indicate an increased current density in the passive range on potentiodynamic curves of studied alloys in the envi- ronment of human saliva, and also in a commercial saliva solution – Mucinox. On the basis of conducted corrosion studies, it can be stated that in terms of corrosion resistance the developed saliva substitutes may constitute competitive solutions to commercial saliva substitutes. The prepared substitutes should be studied further from the perspective of practical application for patients. The original value of the paper is a proposition of new saliva substitutes.
Źródło:
Acta Mechanica et Automatica; 2013, 7, 2; 69-74
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości ścierne stopów Co-Cr w zawiesinie ceramika-sztuczna ślina
Abrasive behaviour of Co-Cr alloys in the ceramic material-artificial saliva suspension
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/284452.pdf
Data publikacji:
2014
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy Co-Cr
testy zużycia ściernego w zawiesinie
protetyka stomatologiczna
Co-Cr alloys
abrasive wear tests in suspension
prosthodontics
Opis:
Publikacja zawiera wyniki badań odporności na ścieranie stopów Co-Cr-Mo i Co-Cr-Mo-W przeprowadzonych na aparacie Millera. W celu oceny podatności na zużycie ścierne w naturalnych warunkach pracy w/w stopów, badania prowadzono w specjalnie zasymulowanym środowisku, składającym się z ceramicznego proszku Dentyna oraz roztworu sztucznej śliny o pH równym 6,7. W ramach badań przeprowadzono obserwacje mikrostruktury przy wykorzystaniu mikroskopu świetlnego stosując kontrast interferencyjno--różniczkowy (kontrast Nomarskiego), wykonano pomiary twardości, zaś powierzchnie po procesie ścierania poddano obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Na postawie przeprowadzonych badań stwierdzono, że stopy Co-Cr-Mo i Co-Cr-Mo-W charakteryzują się wysoką twardością około 400-450 HV10 i minimalnym ubytkiem masy w procesie ścierania. Cechy te świadczą o wysokiej odporności na ścieranie badanych stopów w środowisku proszek ceramiczny-sztuczna ślina. Dodatkowo stwierdzono również, że trzy z badanych stopów Remanium 2001, Colado CC oraz Heraenium P w odróżnieniu od stopu Wironit LA, posiadają przystanki na krzywych ubytku masy w czasie związane z różnicami twardości materiału osnowy β-Co, wydzieleń węglikowych oraz ramion dendrytów. W przypadku stopu Wironit LA obserwowano równomierne zużycie materiału na całej powierzchni. Stwierdzono również, że pomimo różnic w mechanizmach ścierania pomiędzy stopem Wironit LA I Remanium 2001 wielkość ubytku masy jest dla nich na podobnym poziomie, jednak jest ona znacznie niższa niż dla pozostałych dwóch badanych stopów Colado CC ora Heraenium P.
The publication contains the results of the abrasion resistance tests carried out on Co-Cr-Mo and Co-Cr--Mo-W alloys using Miller apparatus. To assess the susceptibility to abrasive wear of the above mentioned alloys under natural operating conditions, tests were carried out in a specially simulated environment, consisting of a ceramic Dentine powder and artificial saliva solution with pH of 6.7. The scope of studies included the examinations of microstructure performed by light microscopy using differential interference contrast (Nomarski contrast), measurements of hardness, and SEM examinations of surfaces after the abrasion process. The results of these studies enabled formulating the conclusion that alloys from the Co-Cr-Mo and Co-Cr-Mo-W systems are characterised by high hardness of about 400-450 HV10 and minimum weight loss in the process of abrasion. These features prove high abrasive wear resistance of the examined alloys in the environment of ceramic powder and artificial saliva. Additionally, it was also found that three of the tested alloys, i.e. Remanium 2001, Colado CC and Heraenium P, unlike the Wironit LA alloy, show time-related arrests on the weight loss curves caused by different hardness values of the β-Co matrix, carbide precipitates and dendrite arms. The Wironit LA alloy was observed to wear evenly across the whole surface. It was also found that, despite differences in abrasion mechanism operating in the Wironit LA and Remanium 2001 alloys, the magnitude of weight loss has been similar and, at the same time, much lower than for the other two alloys tested, i.e. Colado CC and Heraenium P.
Źródło:
Engineering of Biomaterials; 2014, 17, 127; 7-15
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Niskotemperaturowe starzenie cyrkonowych materiałów ceramicznych Y-TZP. Cz. 1. Badania mikrostruktury i przemian fazowych
Low-temperature degradation of Y-TZP zirconia ceramics. Part I: Microscopic observations and phase analysis
Autorzy:
Tymowicz-Grzyb, P.
Jaegermann, Z.
Konopka, G.
Wiśniewski, Z.
Pęczkowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/168854.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
protetyka stomatologiczna
ceramika cyrkonowa
starzenie niskotemperaturowe
XRD
termowizja SEM
dental prosthetics
zirconia ceramics
low-temperature degradation
SEM thermovision
Opis:
Przedmiotem badań było zjawisko starzenia niskotemperaturowego materiałów cyrkonowych. Ma ono ogromny wpływ na funkcjonalność i trwałość elementów wykonanych z ceramiki cyrkonowej. Celem niniejszej pracy było zbadanie początkowych etapów procesu niskotemperaturowego starzenia materiałów cyrkonowych Y-TZP metodami analizy fazowej XRD oraz obserwacji mikroskopowych SEM. Badania fazowe przeprowadzone metodą dyfrakcji rentgenowskiej wykazały wzrost zawartości fazy jednoskośnej w badanych materiałach Y-TZP, co potwierdziło wystąpienie zjawiska starzenia hydrotermalnego. Zawartość fazy jednoskośnej ZrO2 w starzonych próbkach była proporcjonalna do czasu starzenia. Wyniki badań XRD zostały potwierdzone analizą obrazów mikroskopowych SEM.
The subject of the study was the phenomenon of low-temperature degradation (LTD) of Y-TZP zirconia ceramics. It has crucial impact on functionality and stability of zirconia elements. The aim of this work was to investigate the initial stages of LTD process of zirconia ceramics by means of phase analysis XRD and SEM microscopic observations. Phase analysis conducted by X-ray diffraction method showed that the content of monoclinic phase in samples after aging increased. The content of the monoclinic ZrO2 phase in aged samples was proportional to the aging time. XRD results have been confirmed by SEM image analysis.
Źródło:
Szkło i Ceramika; 2017, R. 68, nr 3, 3; 6-10
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Qualitative Assessment of the Defects in Metal Casting Prosthetic Restorations
Autorzy:
Augustyn-Pieniążek, J.
Wilkosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/379721.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt based alloys
casting defects
dental prosthetics
3D scanner
kobalt
wady odlewnicze
protetyka stomatologiczna
skaner 3D
Opis:
Due to the frequent occurrence of casting defects in the casting process of metal prosthetic elements, studies aiming at identifying the defects and determining their probable causes were performed. The work presents the results of the examinations of the Co-Cr-Mo alloy, brand name Argeloy N.P. Special, used for prosthetic restorations. Macroscopic and microscopic observations were conducted with the use of light and scanning microscopy (SEM). Also, the results of the observations by means of a 3D scanner by GOM ATOS 3 were presented. The performed research made it possible to determine and classify casting defects such as blisters, misruns and interscrystalline cracks. It was stated that a stabilized technological process affects the elimination of the casting defect formation.
Źródło:
Archives of Foundry Engineering; 2014, 14, 4 spec.; 7-12
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Physiological parameters analysis of transfemoral amputees with different prosthetic knees
Autorzy:
Li, Sujiao
Cao, Wujing
Yu, Hongliu
Meng, Qiaoling
Chen, Wenming
Powiązania:
https://bibliotekanauki.pl/articles/306380.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
protetyka
kolano
mikroprocesor
chód
energia
transfemoral amputee
microprocessor-controlled prosthetic knee
energy cost
gait efficiency
relative exercise intensity
Opis:
Physiological parameters analysis allows for a precise quantification of energy expenditure of transfemoral amputees with different prosthetic knees. Comparative physiological parameters analysis that indicate the functional characteristics of knee joints is essential to the choice of transfemoral amputee. The aim of this study was to propose a microprocessor-controlled prosthetic knee (i-KNEE) and conducted physiological parameters (energy cost, gait efficiency and relative exercise intensity) comparison of transfemoral amputees with C-leg, Rheo Knee and Mauch under different walking speeds. Methodsː A microprocessor-controlled prosthetic knee with hydraulic damper (i-KNEE) was developed. A two-factor repeated measurement experiment design was used. Each subject was instructed to accept the same treatments. The two factors were type of prosthetic knees (the i-KNEE, the C-Leg, the Rheo Knee and the Mauch) and speed (0.5, 0.7, 0.9, 1.1, 1.3 m/s). The energy cost, gait efficiency and relative exercise intensity of ten transfemoral amputees were measured. Resultsː For all the prosthetic knees, the energy cost increased along with walking speed. There was no significant difference between three microprocessor-controlled prosthetic knees in energy cost. The gait efficiency of Mauch was always less than or equal to other three microprocessor-controlled prosthetic knees in specific walking speed. The relative exercise intensity increased with speed for all the prosthetic knees. More effort was needed for the transfemoral amputees with Mauch than other three microprocessorcontrolled prosthetic knees in the same walking speed. Conclusionsː The use of the microprocessor-controlled knee joints resulted in reduced energy cost, improved gait efficiency and smaller relative exercise intensity.
Źródło:
Acta of Bioengineering and Biomechanics; 2019, 21, 3; 135-142
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Embedded systems ensuring safety for people with disabilities
Autorzy:
Chajduga, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1831326.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
embedded systems
disability
ensuring safety
programmable prosthese
intelligent prosthetics
systemy wbudowane
inwalidztwo
zapewnienie bezpieczeństwa
programowalna proteza
inteligentna protetyka
Opis:
The publication discusses the concept of modern embedded systems that can be programmed and build in bigger systems in order to ensure the safety of people with disabilities. Article presents the definition of embedded system and, also, introduces the definition of the author. What is more, article briefly presents the most popular and developed in the fastest way exemplary systems: ARM, STM32, Raspberry PI, Sony Spresense and NvidiaJetson. Moreover, the main reasons were described why the embedded systems are used in more and more solutions and the factors that strengthen this trend have been noted: labor costs reduction through automation, reduction of costs of development of a new product through the possibility of making quick changes and reduction of product testing time, value creation potential and, also, the way to individualize the possibilities of electronics. Also, the examples of usage of those systems were presented. Finally, the practical side of programming and testing the embedded systems were described: ‘radar‘ (a torch) for blind people, help with balance disorders and the device to help with problems with orientation in space. In the conclusions, author shapes the estimated potential future of electronics supported with modern embedded systems, which as author believes makes this article the comprehensive study.
Źródło:
System Safety : Human - Technical Facility - Environment; 2021, 3, 1; 296-303
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zestaw pomiarowy do badań diagnostycznych protez zębowych
Measuring system for diagnostics of dental prostheses
Autorzy:
Kuchta, M.
Kwiatos, K.
Fokow, K.
Powiązania:
https://bibliotekanauki.pl/articles/327460.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
protetyka stomatologiczna
diagnostyka
kinematyka protez
biomechanika stomatologiczna
system pomiarowy
dental prosthetics
diagnostics
dentures kinematics
dental biomechanics
measuring system
Opis:
Referat przedstawia metodę i układ pomiarowy do obiektywnej oceny jakości materiałów użytych do konstrukcji protez szczękowych jak również samej jej konstrukcji. Opracowany specjalizowany zestaw pomiarowy umożliwia wykonywanie szerokiego zakresu badań statycznych i dynamicznych, w ściśle określonych warunkach, na protezach zębowych.
The paper presents the method and measuring system for an objective assessment of materials used for the construction of prostheses and for the assessment of the constructions as well. The proposed system is capable of conducting wide range static and dynamic examinations of the prostheses.
Źródło:
Diagnostyka; 2006, 3(39); 187-192
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of gold with titanium alloy weldability in conditions of a dental technique laboratory
Autorzy:
Jania, G.
Żmudzki, J.
Topolska, S.
Powiązania:
https://bibliotekanauki.pl/articles/24200598.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Komputerowej Nauki o Materiałach i Inżynierii Powierzchni w Gliwicach
Tematy:
titanium alloy
gold
laser welding
prosthetic
implant denture
microstructure
stop tytanu
złoto
spawanie laserowe
protetyka
proteza implantu
mikrostruktura
Opis:
Purpose: In dental practice, there is necessary to weld gold with titanium under the conditions of a dental technique laboratory, which is difficult. The aim was to assess the weldability of pure gold with the titanium alloy Ti6Al4V using a prosthetic laser welding machine. Design/methodology/approach: Gold wire in a diameter of 0.4 mm made with the use of a jewellery drawbar (GOLDPORT, Szczecin, Poland) was welded to a titanium alloy Ti6Al4V substrate of dental implant abutment screw (MegaGen). Dental laser welding parameters (Bego Laser Star T plus) were 230 V; 6.5 ms; 2.5 Hz; laser spot 0.3 mm, and argon blow. Samples were included in resin, ground (500-4000 SiC), polished (Al2O3 suspension) and etched (Kroll solution) per 20 s before observation under a light microscope. Findings: There were well-welded and poorly joined zones. The discontinuities and voids there were not visible or sparse next to the initial weld point. Dendritic structure at well-welded remelting zones and two-phase microstructure of titanium and Ti3Au phase were found. The heat-affected zone was about of 20 microns. Research limitations/implications: Light microscopy was used, and precise phase identification required further investigations. Weld strength assessment requires further micro-hardness and load-bearing ability tests. Weldability concerns the model system with pure gold. Practical implications: In the case of elements with dimensions below 0.4 mm, the use of a laser with a smaller spot should be considered for better control of the remelting zone and mechanical positioning of the elements in order to stabilize and avoid discontinuities and voids. Originality/value: Prosthetic laser welding with a laser spot about of 0.3 mm allows to obtain well-welded parts of 0.3 mm in diameter under stable stitching conditions and higher than 0.4 mm in dimensions.
Źródło:
Archives of Materials Science and Engineering; 2022, 118, 1; 36--41
1897-2764
Pojawia się w:
Archives of Materials Science and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ZrO2-CeO2 ceramic powders obtained from a sol-gel process using acetylacetone as a chelating agent for potential application in prosthetic dentistry
Autorzy:
Nakonieczny, D.
Paszenda, Z.
Drewniak, S.
Radko, T.
Lis, M.
Powiązania:
https://bibliotekanauki.pl/articles/306436.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
proces zol-żel
metody rentgenowskie
analiza termiczna
ZrO2
protetyka
sol-gel process
X-ray Methods
Thermal Analysis
Prosthetic Dentistry
Opis:
Purpose: The main objective of this study was to obtain single-phase β-ZrO2 powders with so-called soft agglomerates reproducibile morphology with acetyl-acetone as a chelating-agent. To the best of our knowledge there is no avaiable data which determine the effect of acetyl acetone on the phase composition and morphology of ceria-doped ZrO2 powders for biomedical applications. Methods: Twenty variants of powders with different water to zirconia precursor and acetylacetone to zirconia precursor molar ratios were prepared. 0.9ZrO20.1CeO2 powders were obtained by a hydrolysis and condensation and further calcination of zirconium n-propoxide in a simple one-step sol-gel process. Influence of acetyloacetone to zirconia precursor on the phase composition ratio and water to zirconia precursor was investigated. Samples have been characterized by X-ray diffraction (XRD), Raman spectroscopy (RS), thermal analysis (TGA/DTA) and scanning electron microscopy (SEM) measurements. Results: Ceramic powders prepared by sol-gel process, according to the various concentration of chelating agent and water show different morphology and phase composition. Conclusions: Higher molar ratios of AcAc in range with smaller amounts of water cause hard agglomerates, obtained powders are characterized by highly thermally stable behaviour and various phase composition. With higher molar ratios of water to zirconium-n-propoxide so-called soft agglomerates and one phase powders are obtained.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 3; 53-60
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance and Microstructure of Recasting Cobalt Alloys Used in Dental Prosthetics
Autorzy:
Loch, J.
Krzykała, A.
Łukaszczyk, A.
Augustyn-Pieniążek, J.
Powiązania:
https://bibliotekanauki.pl/articles/380935.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
investment casting technology
ceramic moulds
dental prosthetics
cobalt alloys
corrosion resistance
technologia odlewania
formy ceramiczne
protetyka stomatologiczna
stopy kobaltu
odporność na korozję
Opis:
The work presents the results of the studies of Co-Cr-Mo casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo alloys of different contents of Mo, W and other additives. Electrochemical tests were performed, which aimed at examining the corrosion resistance of the alloys and observing the alloy structure after chronoamperometric tests with the potential in the area of the occurrence of the passive layer breakpoint. The alloy microstructure images after chronoamperometric tests show the presence of non-uniformly distributed general corrosion. Moreover, a project of cobalt alloy casting was elaborated using a ceramic mold casting. Additionally, analysis of the obtained microstructure was performed. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure.
Źródło:
Archives of Foundry Engineering; 2017, 17, 2; 63-68
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Literackie wizje życia rozumnego w kosmosie i ich konsekwencje metafizyczne, epistemologiczne i aksjologiczne
Literary visions of intelligent life in space and its metaphysical, epistemological and axiological consequences
Autorzy:
Sobota, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/431319.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Kardynała Stefana Wyszyńskiego w Warszawie
Tematy:
science fiction
literature
extraterrestrial life
value conflict
cognitive drama
‘substitution in metaphysics’
literatura
życie pozaziemskie
konflikt wartości
dramat poznawczy
'protetyka' metafizyczna
Opis:
Science Fiction literature described for decades an intelligent form of life on other planets. This scenario raises obvious questions, such as whether we can understand a mind developed in an entirely different environment than our own and equipped with different perceptual capacities. Stanisław Lem’s “Solaris” is perhaps the best realisation of this scenario – a novel where mankind tries to communicate with a giant ocean of plasma, a living organism radically different from human life. “Roadside Picnic” by the Stugatsky brothers raises another problem exemplified in the title itself, which is a metaphor for potential cultural differences between alien civilisation and homo sapiens. Yet another intriguing question concerns the metaphysical and theological consequences deriving from exchanges with non-human civilisations. There seems to be a problem of ‘substitution in metaphysics’ in Science Fiction literature (i.e., replace a wonder with technology, or God with technologically almighty aliens).
Literatura fantastycznonaukowa od dziesięcioleci kreśli wizje życia rozumnego na innych planetach. Rodzą się oczywiste pytania: czy możliwe jest porozumienie z intelektem rozwiniętym w skrajnie różnym od ludzkiego środowisku, wyposażonym być może w odmienną percepcję, odmienne sposoby odbioru rzeczywistości. Najciekawszą realizacją tematu wydaje się powieść Stanisława Lema „Solaris”, w której ludzkość próbuje komunikować się z gigantycznym oceanem plazmy, a więc istotą skrajnie od ludzkości różną. Inny problem sygnalizują bracia Strugaccy w książce „Piknik na skraju drogi” – tytuł jest metaforą opisującą różnicę potencjałów kulturowych między obcą cywilizacją a homo sapiens. Inne intrygujące pytanie – jakie konsekwencje metafizyczno-teologiczne niesie ze sobą kontakt z obcymi cywilizacjami; pojawia się problem „protezowania metafizyki” w literaturze fantastycznej (czyli zastępowania cudowności technologią, Boga – figurą wszechmocnego technologicznie obcego).
Źródło:
Studia Philosophiae Christianae; 2016, 52, 3; 175-193
0585-5470
Pojawia się w:
Studia Philosophiae Christianae
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza numeryczna protezy szkieletowej podpartej ozębnowo i śluzówkowo
Numerical analysis of static partial denture supported periodontium end gum
Autorzy:
Gralewski, J.
Bogusławski, G.
Powiązania:
https://bibliotekanauki.pl/articles/99203.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza dentystyczna
MES (metoda elementów skończonych)
ANSYS
analiza wytrzymałościowa
model numeryczny
prosthodontics
dental prosthesis
FEM
strength analysis
numerical model
Opis:
W pracy przeprowadzono analizę stanu naprężenia i odkształcenia wybranej konstrukcji protezy szkieletowej oraz reakcji podporowych dla różnych przypadków obciążeń. Uzyskane wyniki obliczeń protezy pozwolą określić sztywność i wytrzymałość konstrukcji, a reakcje podporowe pozwolą wyznaczyć obciążenia zębów filarowych. Analizę przeprowadzono za pomocą metody elementów skończonych w programie ANSYS. Model 3D protezy został stworzony poprzez skanowanie ręcznym skanerem optycznym rzeczywistej protezy szkieletowej gdzie po uzyskaniu chmury punktów został poddany wygładzaniu, stworzono model powierzchniowy a następnie przekonwertowano do postaci bryłowej. Analiza stanu naprężenia i odkształcenia pozwoli uzyskać odpowiedz gdzie występują koncentracje naprężeń w protezie oraz w jaki sposób proteza pod wpływem obciążenia siłami zgryzowymi przenosi siły na zęby oporowe.
The papers deals with the stress and strain analysis for arbitrary chosen construction of denture. The constrain reaction for different load cases was consider. The results of calculation allow to specify stiffness and strength for analysed denture. The obtained reaction allow to define the load subjected the teeth. The ANSYS software based on finite element method was employed for calculation. To create the virtual geometry of denture the opticalscanner was used. From the cloud of points the 3D model of denture geometry was build. In the first step the outer surface of denture was created and then in the second step from the surface the solid model was generated.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 41-46
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biozgodność stopów protetycznych w funkcji czasu
Biocompatibility of prosthetic alloys as a function of time
Autorzy:
Hajduga, M.
Kalukin, B.
Kalukin, A.
Powiązania:
https://bibliotekanauki.pl/articles/99348.pdf
Data publikacji:
2009
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
protetyka stomatologiczna
proteza dentystyczna
uzupełnienie protetyczne
stop protetyczny
implantacyjna stal austenityczna
biozgodność
prosthodontics
dental prosthesis
prosthetic restoration
prosthetic alloy
implantation austenitic steel
biocompatibility
Opis:
Od przeszło 3000 lat główną grupą materiałów, przeznaczonych do implantacji w organizmie ludzkim są metale i ich stopy. W ostatnim stuleciu najczęściej używana była i jest do dzisiaj implantacyjna stal austenityczna. W ostatnich 30 latach częściowo wyparły ją stopy niklu, kobaltu czy tytanu. Jedną z funkcji, mających wpływ na biozgodność materiału jest czas przebywania konstrukcji w agresywnym środowisku płynów ustrojowych. Autorzy podjęli próbę określenia zakresu zmian w materiałach metalicznych, po długotrwałej implantacji w jamie ustnej. Celem pracy jest określenie wpływu czasu użytkowania na zmianę właściwości materiałowych stopów stomatologicznych. W jej zakresie mieszczą się mikroskopowe badania metalograficzne, mikroanaliza rentgenowska oraz badania mikrotwardości. Wstępna analiza wyników potwierdza tak szerokie rozpowszechnienie implantacyjnej stali austenitycznej.
From 3000 years the majority of materials made for implantation in the human body are metals and alloys. In the last century the most commonly used was steel austenitic implantation. In the past 30 years, it was partly replaced by nickel alloys, cobalt alloys and titanium. One of the functions having the effect on biocompatibility of material is time of construction in aggressive environment, body fluids. The authors undertook an attempt to determine the extent of changes in the metallic materials after long-term implantation in the oral cavity. The aim of this work is to determine the effect of time for a change of using the material used in dental alloys. In this field there are metallographic microscopic examinations, X-ray microanalysis and micro hardness. Preliminary analysis of the results confirms such a wide spread of implantation austenitic steel.
Źródło:
Aktualne Problemy Biomechaniki; 2009, 3; 53-58
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microstructural and micromechanical tests of titanium biomaterials intended for prosthetic reconstructions
Autorzy:
Ryniewicz, A. M.
Bojko, Ł.
Ryniewicz, W. I.
Powiązania:
https://bibliotekanauki.pl/articles/307469.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
CAD/CAM
protetyka stomatologiczna
DMLS
mikrostruktura
mikrotwardość
tytan
stop tytanu
CAD/CAM system
dental prosthetics
direct metal laser sintering
microstructure
microhardness
titanium
titanium alloy
Opis:
Purpose: The aim of the present paper was a question of structural identification and evaluation of strength parameters of Titanium (Ticp – grade 2) and its alloy (Ti6Al4V) which are used to serve as a base for those permanent prosthetic supplements which are later manufactured employing CAD/CAM systems. Methods: Microstructural tests of Ticp and Ti6Al4V were conducted using an optical microscope as well as a scanning microscope. Hardness was measured with the Vickers method. Micromechanical properties of samples: microhardness and Young’s modulus value, were measured with the Oliver and Pharr method. Results: Based on studies using optical microscopy it was observed that the Ticp from the milling technology had a single phase, granular microstructure. The Ti64 alloy had a two-phase, fine-grained microstructure with an acicular-lamellar character. The results of scanning tests show that titanium Ticp had a single phase structure. On its grain there was visible acicular martensite. The structure of the two phase Ti64 alloy consists of a β matrix as well as released α phase deposits in the shape of extended needles. Micromechanical tests demonstrated that the alloy of Ti64 in both methods showed twice as high the microhardness as Ticp. In studies of Young’s modulus of Ti64 alloy DMLS technology have lower value than titanium milling technology. Conclusions: According to the results obtained, the following conclusion has been drawn: when strength aspect is discussed, the DMLS method is a preferred one in manufacturing load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 121-127
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected properties and tribological wear alloys Co-Cr-Mo and Co-Cr-Mo-W used in dental prosthetics
Wybrane właściwości oraz zużycie tribologiczne stopów, Co-Cr-Mo i Co-Cr-Mo-w stosowanych w protetyce stomatologicznej
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Sulima, I.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/356345.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Co-Cr alloys
wear
slurry abrasion test (“Miller test”)
dental prosthetics
Co-Cr stopy
zużycie
badanie zużycia ściernego stopów
aparat Millera
protetyka stomatologiczna
Opis:
The presented work provides the results of the abrasive wear resistance tests performed on Co-Cr-Mo and Co-Cr-Mo-W alloys with the use of the Miller’s apparatus. The analyzed alloys underwent microstructure observations as well as hardness measurements, and the abraded surfaces of the examined materials were observed by means of electron scanning microscopy. The performed examinations made it possible to state that the Co-Cr alloys characterized in a high hardness, whereas the changes in the mass decrement were minimal, which proved a high abrasive wear resistance.
W prezentowanej pracy przedstawiono wyniki badań zużycia ściernego stopów, Co-Cr-Mo i Co-Cr-Mo-W przy użyciu aparatu Millera. Analizowane stopy poddano obserwacjom mikrostruktury, pomiarom twardości i mikrotwardości, a ścierane powierzchnie badanych materiałów obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Przeprowadzone badania pozwoliły na stwierdzenie, że stopy, Co-Cr charakteryzowały się wysoką twardością i mikrotwardością, zaś zmiany ubytku masy były bardzo minimalne, co świadczy o wysokiej odporności na ścieranie.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1569-1574
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania biomateriałów metalowych do komputerowego wspomagania projektowania i wytwarzania stałych konstrukcji protetycznych
Tests metallic biomaterials for computer-aided design and manufacturing of fixed prosthetic restorations
Autorzy:
Ryniewicz, A.
Bojko, Ł.
Ryniewicz, W.
Pałka, P.
Powiązania:
https://bibliotekanauki.pl/articles/197737.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
DMLS
mikrostruktura
mikrotwardość
moduł Younga
protetyka stomatologiczna
CAD/CAM
tytan
stop tytanu
direct metal laser sintering (DMLS)
microstructure
microhardness
Young's modulus
dental prosthetics
titanium
titanium alloy
Opis:
Laserowe spiekanie proszków metali (DMLS) jest nową technologią otrzymywania konstrukcji w procedurze CAD/CAM. Celem opracowania były identyfikacja strukturalna i wyznaczenie parametrów wytrzymałościowych tytanu oraz stopów tytanu przeznaczonych na podbudowy stałych uzupełnień protetycznych otrzymywanych przy komputerowym wspomaganiu projektowania i wytwarzania. Materiałem badań były próbki z czystego technicznie tytanu – gatunek 1 do wytworzenia konstrukcji w technologii obróbki frezowaniem oraz próbki Ti6Al4V z technologii laserowego, przyrostowego spiekania proszków. Wykonano badania mikrostrukturalne i mikromechaniczne. Na ich podstawie stwierdzono, że w aspekcie wytrzymałościowym DMLS jest technologią preferowaną do wykonawstwa stałych konstrukcji nośnych dla protetyki stomatologicznej i może stanowić alternatywę dla systemu CAD/CAM z obróbką ubytkową.
A direct metal laser sintering method (DMLS) is a new technology used for getting structures by the CAD/CAM procedures. The aim of the elaboration was a question of structural identification and setting strength parameters of titanium (Ticp) and its alloy (Ti6Al4V) which are used to serve as base for those permanent prosthetic supplements which are later manufactured with the employment of CAD/CAM systems. The research work was performed on Ticp samples – those which were intended for manufacture of structures by decrement milling working, and Ti6Al4V samples that comes from laser increment sintering of powder. According to the results obtained, the following conclusion has been derived: when strength aspect is discussed, the DMLS method is a preferred one for manufacturing of load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.
Źródło:
Zeszyty Naukowe. Transport / Politechnika Śląska; 2014, 82; 225-234
0209-3324
2450-1549
Pojawia się w:
Zeszyty Naukowe. Transport / Politechnika Śląska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania materiałowe i korozyjne konwencjonalnych stopów Co-Cr-Mo-W przeznaczonych na odlewy konstrukcji szkieletowych w protetyce dentystycznej
Material and corrosion studies of conventional Co-Cr-Mo-W alloys for frame construction casts in dental prosthetics
Autorzy:
Augustyn-Pieniążek, J.
Łukaszczyk, A.
Loch, J.
Powiązania:
https://bibliotekanauki.pl/articles/285880.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
konwencjonalne stopy na osnowie kobaltu
protetyka dentystyczna
roztwór sztucznej śliny
odporność korozyjna
woltamperometria liniowa
conventional cobalt-based alloys
dental prosthetics
artificial saliva solution
corrosion resistance
linear sweep voltammetry
Opis:
Podstawowe cechy jakimi powinny charakteryzować się materiały stosowane na protezy szkieletowe w stomatologii to biotolerancja w środowisku tkanek i płynów ustrojowych oraz duża odporność na korozję wżerową i szczelinową. Ważna jest również stabilność zespołu określonych własności fizyczno-mechanicznych (wysoka wytrzymałość, odpowiednia ciągliwość, twardość i odporność na ścieranie) oraz jednorodność składu chemicznego W pracy przedstawiono wyniki badań konwencjonalnych stopów odlewniczych Co-Cr-Mo-W stosowanych do wykonywania odlewów szkieletów protez ruchomych, koron i mostów w protetyce dentystycznej. Badania wykonano na czterech stopach Co-Cr-Mo-W o różnej zawartości Mo, W oraz innych domieszek. W pracy dokonano analizy mikrostruktury stopów z zastosowaniem mikroskopu świetlnego oraz elektronowego mikroskopu skaningowego. Dodatkowo wykonano pomiary mikrotwardości metodą Vickersa oraz badania odporności korozyjnej. Dla każdego z badanych stopów Co-Cr-Mo-W wykreślono zależność potencjału stacjonarnego w funkcji czasu oraz wykonano badania woltamperometryczne w środowisku sztucznej śliny. Przeprowadzone obserwacje metalograficzne pozwoliły stwierdzić, że analizowane materiały charakteryzowały się budową dendrytyczną typową dla stopów odlewanych. Mikrostruktura ta jest chemicznie niejednorodna, złożona z austenitycznej osnowy składającej się z roztworu stałego kobaltu oraz chromu w rdzeniowej strukturze dendrytycznej. Stopy charakteryzowały się wysoką twardością. Wzrost mikrotwardości jest silnie determinowany występowaniem wydzieleń węglikowych M23C6, które zapewniają dużo silniejsze umocnienie stopu. Analizowane stopy wykazywały zbliżone przebiegi krzywych polaryzacji. Zachowanie elektrochemiczne stopów Co-Cr-Mo-W w dużej mierze zależy od zawartości w stopie chromu i molibdenu, pierwiastków, które przyczyniają się do pasywacji stopów.
The basic characteristics of skeletal prosthetic materials used in dentistry are: biotolerance with tissues and body fluids, as well as high pitting and crevice corrosion resistance. Also important are such characteristics as: high strength, adequate ductility, hardness and abrasion resistance, as well as homogeneity of the chemical composition. The work presents the results of the studies of conventional Co-Cr-Mo-W casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo-W alloys of different contents of Mo, W and other additives. The work analyzes the alloys microstructures with the use of a light microscope and a scanning electron microscope. Additionally, hardness measurements were made by means of the Vickers method and corrosion resistance tests were conducted. For each examined Co-Cr-Mo-W alloy, the open circuit potential as a function of time was determined and voltamperometric tests were performed in artificial saliva. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure. The investigated alloys were characterized by high hardness. The increase in the microhardness was depended on the presence of carbide precipitates M23C6, which provide a much stronger reinforcement of the alloy. The analyzed materials exhibited a similar progress of the polarization curves. The electrochemical corrosion of Co-Cr-Mo-W alloys was depended on the content of chromium and molybdenum, which largely contributed to alloy passivation.
Źródło:
Engineering of Biomaterials; 2015, 18, 130; 2-9
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena odporności korozyjnej stopu TI-6AL-4V po obróbce strumieniowo-ściernej stosowanym w protetyce stomatologicznej
Evaluation of corrosion resistance of Ti-6Al-4V alloys after blasting used in dental prosthetics
Autorzy:
Zapart, M.
Krawczyk, C.
Radwin, E.
Czerwik, M.
Sarraj, S.
Powiązania:
https://bibliotekanauki.pl/articles/99059.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
stop Ti-6Al-4V
protetyka stomatologiczna
korozja wżerowa
korozja szczelinowa
kąt zwilżania
Ti-6Al-4V alloy
dental prosthetics
pitting corrosion
crevice corrosion
contact angle
Opis:
Niniejsza praca dotyczy badań odporności korozyjnej stopu Ti-6Al-4V o zmodyfikowanej powierzchni poprzez obróbkę mechaniczną (szlifowanie, polerowanie oraz obróbka strumieniowo-ścierna) do zastosowań w protetyce stomatologicznej. W ramach pracy przeprowadzono pomiar kąta zwilżania oraz badania odporności na korozje wżerową i szczelinową. Uzyskane wyniki jednoznacznie wykazały, że niezależnie od rodzaju modyfikacji powierzchni stop Ti-6Al-4V ma charakter hydrofilowy i jest odporny na korozję wżerową i szczelinową.
This work concerns tests of corrosion resistance of Ti-6Al-4V alloy with modified surface by mechanical treatment (grinding, polishing and abrasive blasting treatment) for applications in dental prosthetics. As part of the work, was measured the contact angle as well as the pitting and crevice corrosion resistance tests. Obtained results clearly showed that regardless of the type of surface modification, the Ti-6Al-4V alloy is hydrophilic and resistant to pitting and crevice corrosion.
Źródło:
Aktualne Problemy Biomechaniki; 2018, 16; 41-46
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-42 z 42

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies