Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "prosthetics" wg kryterium: Temat


Tytuł:
Effect of Remelting of the Ni-22Cr-9Mo Alloy on its Microstructural and Electrochemical Properties
Autorzy:
Augustyn-Nadzieja, J.
Łukaszczyk, A.
Loch, J.
Powiązania:
https://bibliotekanauki.pl/articles/351218.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Ni-Cr-Mo alloys
metal prosthetics restorations
method melted models
artificial saliva solution
corrosion resistance
Opis:
The Ni-Cr-Mo alloys are used as the alternative for the cobalt alloys in the manufacture of metal prosthetic elements, i.e. crowns, bridges and frame prostheses. The article attempts at a materials science characterization of the nickel-based alloy of the commercial name Argeloy N.P Be-Free by Argen. Within the study, examinations were made on the commercial alloy as well as the alloy which was remelted and cast by the los mould (lost wax) method. Observations of the microstructure were performed with the use of optical and electron scanning microscopy. Also, X-ray structural tests were conducted as well as corrosion resistance tests in an artificial saliva solution (pH = 6,7). It was demonstrated that the examined Ni-22Cr-9Mo alloy characterized in a dendritic structure typical of the cast materials. The X-ray qualitative phase analysis revealed the phase γ'(Ni) in both examined materials, as well as the presence of Cr23C6 type carbides and Nb2C, Ta2C (commercial alloy) and NbC, Ta4C0,04 (cast alloy) phases. The effect of the alloy’s remelting and the morphology of the passive layer on the corrosion resistance of the Ni-Cr-Mo alloy was examined. The results of the electrochemical tests show that the process of re-casting only slightly affects the corrosion resistance and the microstructure of the considered alloy. The roles of recasting process and the passive film homogeneity on the corrosion resistance of Ni-Cr-Mo dental alloy were reviewed. The results the electrochemical study show that the dependence of corrosion resistance on the microstructure associated with the recasting process is marginal.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 1; 411-418
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of prosthetic elements manufacturing technology on properties and microstructure shaping Co-Cr-Mo alloys
Autorzy:
Augustyn-Nadzieja, Joanna
Szczotok, Agnieszka
Powiązania:
https://bibliotekanauki.pl/articles/1844979.pdf
Data publikacji:
2020
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
Co-Cr-Mo alloys
dental prosthetics
lost wax casting method
selective laser sintering of metal powders (DLMS)
microstructure
hardness
Opis:
The presented publication discusses the test results regarding samples of a prosthetic alloy from the Co-Cr-Mo system. The test samples were obtained by means of two different methods applied in prosthetics laboratories to compare their properties and microstructure. To obtain the samples via the traditional lost wax casting method, the cast alloy Co-Cr-Mo was used, commercially known as Wironit LA. In the case of the modern technique DMLS (Direct Metal Laser Sintering), metallic powder Co-Cr-Mo, called EOS Cobalt Chrome MP1, was used. The samples of both Co-Cr-Mo alloys obtained via the two methods were prepared for metallographic tests; they also underwent microstructural observations with the use of light microscopy (LM) and scanning electron microscopy (SEM), and next they were subjected to hardness tests. The obtained samples demonstrated a dendritic structure. In the samples cast with the lost wax casting method, a segregation of the chemical composition was revealed. The samples obtained by means of the DLMS method were characterized by chemical composition homogeneity. The hardness measurements with the statistical analysis of the measurement results showed a difference between the examined alloys. On the basis of the performed studies, it was stated that the applied methods of manufacturing prosthetic elements make it possible to obtain diversified microstructural and mechanical properties of the alloys. The hardness value significantly affects the subsequent mechanical and finishing treatment of prosthetic elements, such as metal bases of crown caps, bridges, mobile prostheses or other retention elements.
Źródło:
Engineering of Biomaterials; 2020, 23, 156; 24-31
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania materiałowe i korozyjne konwencjonalnych stopów Co-Cr-Mo-W przeznaczonych na odlewy konstrukcji szkieletowych w protetyce dentystycznej
Material and corrosion studies of conventional Co-Cr-Mo-W alloys for frame construction casts in dental prosthetics
Autorzy:
Augustyn-Pieniążek, J.
Łukaszczyk, A.
Loch, J.
Powiązania:
https://bibliotekanauki.pl/articles/285880.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
konwencjonalne stopy na osnowie kobaltu
protetyka dentystyczna
roztwór sztucznej śliny
odporność korozyjna
woltamperometria liniowa
conventional cobalt-based alloys
dental prosthetics
artificial saliva solution
corrosion resistance
linear sweep voltammetry
Opis:
Podstawowe cechy jakimi powinny charakteryzować się materiały stosowane na protezy szkieletowe w stomatologii to biotolerancja w środowisku tkanek i płynów ustrojowych oraz duża odporność na korozję wżerową i szczelinową. Ważna jest również stabilność zespołu określonych własności fizyczno-mechanicznych (wysoka wytrzymałość, odpowiednia ciągliwość, twardość i odporność na ścieranie) oraz jednorodność składu chemicznego W pracy przedstawiono wyniki badań konwencjonalnych stopów odlewniczych Co-Cr-Mo-W stosowanych do wykonywania odlewów szkieletów protez ruchomych, koron i mostów w protetyce dentystycznej. Badania wykonano na czterech stopach Co-Cr-Mo-W o różnej zawartości Mo, W oraz innych domieszek. W pracy dokonano analizy mikrostruktury stopów z zastosowaniem mikroskopu świetlnego oraz elektronowego mikroskopu skaningowego. Dodatkowo wykonano pomiary mikrotwardości metodą Vickersa oraz badania odporności korozyjnej. Dla każdego z badanych stopów Co-Cr-Mo-W wykreślono zależność potencjału stacjonarnego w funkcji czasu oraz wykonano badania woltamperometryczne w środowisku sztucznej śliny. Przeprowadzone obserwacje metalograficzne pozwoliły stwierdzić, że analizowane materiały charakteryzowały się budową dendrytyczną typową dla stopów odlewanych. Mikrostruktura ta jest chemicznie niejednorodna, złożona z austenitycznej osnowy składającej się z roztworu stałego kobaltu oraz chromu w rdzeniowej strukturze dendrytycznej. Stopy charakteryzowały się wysoką twardością. Wzrost mikrotwardości jest silnie determinowany występowaniem wydzieleń węglikowych M23C6, które zapewniają dużo silniejsze umocnienie stopu. Analizowane stopy wykazywały zbliżone przebiegi krzywych polaryzacji. Zachowanie elektrochemiczne stopów Co-Cr-Mo-W w dużej mierze zależy od zawartości w stopie chromu i molibdenu, pierwiastków, które przyczyniają się do pasywacji stopów.
The basic characteristics of skeletal prosthetic materials used in dentistry are: biotolerance with tissues and body fluids, as well as high pitting and crevice corrosion resistance. Also important are such characteristics as: high strength, adequate ductility, hardness and abrasion resistance, as well as homogeneity of the chemical composition. The work presents the results of the studies of conventional Co-Cr-Mo-W casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo-W alloys of different contents of Mo, W and other additives. The work analyzes the alloys microstructures with the use of a light microscope and a scanning electron microscope. Additionally, hardness measurements were made by means of the Vickers method and corrosion resistance tests were conducted. For each examined Co-Cr-Mo-W alloy, the open circuit potential as a function of time was determined and voltamperometric tests were performed in artificial saliva. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure. The investigated alloys were characterized by high hardness. The increase in the microhardness was depended on the presence of carbide precipitates M23C6, which provide a much stronger reinforcement of the alloy. The analyzed materials exhibited a similar progress of the polarization curves. The electrochemical corrosion of Co-Cr-Mo-W alloys was depended on the content of chromium and molybdenum, which largely contributed to alloy passivation.
Źródło:
Engineering of Biomaterials; 2015, 18, 130; 2-9
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Qualitative Assessment of the Defects in Metal Casting Prosthetic Restorations
Autorzy:
Augustyn-Pieniążek, J.
Wilkosz, K.
Powiązania:
https://bibliotekanauki.pl/articles/379721.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt based alloys
casting defects
dental prosthetics
3D scanner
kobalt
wady odlewnicze
protetyka stomatologiczna
skaner 3D
Opis:
Due to the frequent occurrence of casting defects in the casting process of metal prosthetic elements, studies aiming at identifying the defects and determining their probable causes were performed. The work presents the results of the examinations of the Co-Cr-Mo alloy, brand name Argeloy N.P. Special, used for prosthetic restorations. Macroscopic and microscopic observations were conducted with the use of light and scanning microscopy (SEM). Also, the results of the observations by means of a 3D scanner by GOM ATOS 3 were presented. The performed research made it possible to determine and classify casting defects such as blisters, misruns and interscrystalline cracks. It was stated that a stabilized technological process affects the elimination of the casting defect formation.
Źródło:
Archives of Foundry Engineering; 2014, 14, 4 spec.; 7-12
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected properties and tribological wear alloys Co-Cr-Mo and Co-Cr-Mo-W used in dental prosthetics
Wybrane właściwości oraz zużycie tribologiczne stopów, Co-Cr-Mo i Co-Cr-Mo-w stosowanych w protetyce stomatologicznej
Autorzy:
Augustyn-Pieniążek, J.
Kurtyka, P.
Sulima, I.
Stopka, J.
Powiązania:
https://bibliotekanauki.pl/articles/356345.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Co-Cr alloys
wear
slurry abrasion test (“Miller test”)
dental prosthetics
Co-Cr stopy
zużycie
badanie zużycia ściernego stopów
aparat Millera
protetyka stomatologiczna
Opis:
The presented work provides the results of the abrasive wear resistance tests performed on Co-Cr-Mo and Co-Cr-Mo-W alloys with the use of the Miller’s apparatus. The analyzed alloys underwent microstructure observations as well as hardness measurements, and the abraded surfaces of the examined materials were observed by means of electron scanning microscopy. The performed examinations made it possible to state that the Co-Cr alloys characterized in a high hardness, whereas the changes in the mass decrement were minimal, which proved a high abrasive wear resistance.
W prezentowanej pracy przedstawiono wyniki badań zużycia ściernego stopów, Co-Cr-Mo i Co-Cr-Mo-W przy użyciu aparatu Millera. Analizowane stopy poddano obserwacjom mikrostruktury, pomiarom twardości i mikrotwardości, a ścierane powierzchnie badanych materiałów obserwacji przy wykorzystaniu elektronowej mikroskopii skaningowej. Przeprowadzone badania pozwoliły na stwierdzenie, że stopy, Co-Cr charakteryzowały się wysoką twardością i mikrotwardością, zaś zmiany ubytku masy były bardzo minimalne, co świadczy o wysokiej odporności na ścieranie.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 3A; 1569-1574
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Struktura i własności mechaniczne modyfikowanych stopów CoCrMo do zastosowań w protetyce stomatologicznej
Structure and mechanical properties of modified CoCrMo alloys for use in dental prosthetics
Autorzy:
Beer, K.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/285534.pdf
Data publikacji:
2011
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
protetyka stomatologiczna
biomateriały
stopy CoCrMo
dental prosthetics
biomaterials
Co-Cr-Mo alloys
Opis:
Większość klinicznych niepowodzeń w przypadku protez stomatologicznych związana jest przede wszystkim z techniką wytapiania i odlewania oraz ilością użytego do wsadu stopu już raz przetopionego. W pracy dokonano analizy wpływu ilości materiału z recyklingu na właściwości mechaniczne i strukturę stomatologicznego stopu CoCrMo. Zastosowano metodę odlewania odśrodkowego, oraz jednokrotne przetopy o składzie wyjściowym odpowiednio 0, 25, 50, 75 i 100% złomu. Przeprowadzono statyczną próbę rozciągania, pomiar mikrotwardości, analizę mikrostrukturalną oraz obserwację SEM przełomów. Stwierdzono, że własności mechaniczne wszystkich przetapianych stopów są gorsze niż stopu czystego, zakupionego u zagranicznego producenta. Mikrostruktura przełomów przetapianych stopów z zawartością złomu powyżej 50% jest bardziej niejednorodna i w strukturze dendrytycznej widoczna jest większa ilość mikropęknięć. Podczas zrywania próbek zarejestrowano wyraźne obniżenie granicy plastyczności i wytrzymałości tych stopów w próbach zrywania w porównaniu z próbkami ze stopów zawierających mniejszą ilość materiału z recyklingu.
The majority of clinical failures in the case of dental prostheses is associated primarily with the technique and the amount of remelted alloy used for the casting. The majority of clinical failures in the case of dental prostheses is associated primarily with the technique of remelting and casting, and quantity of the once remelted alloy used for the batch. The paper analyzes the impact of the amounts of recycled material on the mechanical properties and structure of dental alloy CoCrMo. The centrifugal casting method has been applied and remelted alloys with output composition of 0, 25, 50, 75 and 100% of scrap respectively. The static tensile test, microstructural analysis and SEM observation as well as microhardness test have been conducted. These all tests show that the mechanical strength of all remelted alloys is worse than the strength of the fine alloy, purchased from a foreign manufacturer. The microstructure of breakthroughs of the remelted alloys containing more than 50% of scrap is more heterogeneous and a higher amount of microcracks is visible in the dendritic structure. When the samples were tested in the static tension test, the significant decrease in the yield strength and the tensile strength of these alloys during these static tension tests in comparison to the samples of alloys containing lower amount of the recycled material were observed.
Źródło:
Engineering of Biomaterials; 2011, 14, no. 106-108; 110-115
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Embedded systems ensuring safety for people with disabilities
Autorzy:
Chajduga, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/1831326.pdf
Data publikacji:
2021
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
embedded systems
disability
ensuring safety
programmable prosthese
intelligent prosthetics
systemy wbudowane
inwalidztwo
zapewnienie bezpieczeństwa
programowalna proteza
inteligentna protetyka
Opis:
The publication discusses the concept of modern embedded systems that can be programmed and build in bigger systems in order to ensure the safety of people with disabilities. Article presents the definition of embedded system and, also, introduces the definition of the author. What is more, article briefly presents the most popular and developed in the fastest way exemplary systems: ARM, STM32, Raspberry PI, Sony Spresense and NvidiaJetson. Moreover, the main reasons were described why the embedded systems are used in more and more solutions and the factors that strengthen this trend have been noted: labor costs reduction through automation, reduction of costs of development of a new product through the possibility of making quick changes and reduction of product testing time, value creation potential and, also, the way to individualize the possibilities of electronics. Also, the examples of usage of those systems were presented. Finally, the practical side of programming and testing the embedded systems were described: ‘radar‘ (a torch) for blind people, help with balance disorders and the device to help with problems with orientation in space. In the conclusions, author shapes the estimated potential future of electronics supported with modern embedded systems, which as author believes makes this article the comprehensive study.
Źródło:
System Safety : Human - Technical Facility - Environment; 2021, 3, 1; 296-303
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Risk Assessment of Individualized 3D Printed Prostheses Using Failure Mode and Effect Analysis
Autorzy:
Górski, Filip
Sahaj, Natalia
Kuczko, Wiesław
Żukowska, Magdalena
Hamrol, Adam
Powiązania:
https://bibliotekanauki.pl/articles/2201782.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
PFMEA method
3D printing
risk assessment
prosthetics
Opis:
Risk analysis of personalized medical devices, such as prostheses, is a challenging task due to the complexity of technological and geometrical issues. The paper undertakes a process of risk analysis for upper limb prostheses for adult patients, individualized by 3D scanning and produced by additive manufacturing. The analysis was performed to systematize the process and its steps, as well as diagnose certain problems, in order to achieve future devices with correct fit and function, produced in as few iterations as possible. The Failure Mode and Effect Analysis of Process (PFMEA) method was used. In the results, main process risks were identified: the problems are mostly caused in stages, where operator’s decision or activity is to be performed, regarding socket length, offset and suitable lining. The main prevention activities were determined – human involvement in the decision process should be minimal and the intelligent models should be adjustable to as many patient cases as possible. In consequence, future steps for process optimization were determined – larger base of patient cases is necessary to acquire and study, to gather data for model and process improvement.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 4; 189--200
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Materiały ceramiczne dla protetyki stomatologicznej - właściwości optyczne i mikrostrukturalne wybranych materiałów cyrkonowych
Ceramic materials for dental prosthetics - optical and microstructural properties of zirconia ceramics
Autorzy:
Jaegermann, Z.
Powiązania:
https://bibliotekanauki.pl/articles/168970.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
protetyka stomatologiczna
materiały cyrkonowe
przeświecalność
mikrostruktura
dental prosthetics
zirconia materials
translucency
microstructure
Opis:
Celem badań było wybranie metody oznaczania przeświecalności, porównanie cech optycznych wybranych materiałów cyrkonowych, a także próba określenia zależności przeświecalności od wybranych właściwości fizycznych i cech mikrostrukturalnych materiałów cyrkonowych. Przygotowano i zbadano próbki komercyjnych materiałów cyrkonowych stosowanych w protetyce stomatologicznej w zakresie ich podstawowych właściwości fizycznych i optycznych (gęstość pozorna, barwa, przeświecalność, białość). Ponadto wykonano badania mikroskopowe morfologii porów i ziaren oraz przeprowadzono ocenę zależności przeświecalności od właściwości fizycznych i budowy materiałów cyrkonowych. Scharakteryzowano właściwości optyczne badanych materiałów cyrkonowych i wskazano właściwości, które miały największy wpływ na przeświecalność materiałów.
The aim of the work was to select the method of determine the value of translucency, a comparison of the optical characteristics of the selected zirconia materials, as well as an attempt to determine the relationships between the translucency and selected physical properties and microstructure characteristics of zirconia materials. The samples of commercial zirconia materials used in prosthetic dentistry were prepared and studied their basic physical and optical properties (apparent density, color, translucency, whiteness). Microscopic examination of pores and grain morphology was also performed, as well as translucency dependence on the physical properties and structure of zirconia ceramics was evaluated. In summary, characteristics in terms of the optical properties of the test materials were achieved and properties that, based on the research, had the greatest impact on translucency of materials were indicated.
Źródło:
Szkło i Ceramika; 2013, R. 64, nr 2, 2; 4-13
0039-8144
Pojawia się w:
Szkło i Ceramika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of the remelting on transformations in Co-Cr-Mo prosthetics alloy
Autorzy:
Kacprzyk, B.
Szymczak, T.
Gumienny, G.
Klimek, L.
Powiązania:
https://bibliotekanauki.pl/articles/382914.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
theory of crystallization
remelting
thermal analysis
derivative analysis
microstructure
composition
alloys properties
prosthetics alloys
teoria krystalizacji
przetapianie
analiza termiczna
analiza derywacyjna
mikrostruktura
właściwości stopu
stop protetyczny
Opis:
In the article we were studing the impact of the remelting on transformations in Co-Cr-Mo prosthetics alloy. The TDA curves were analyzed, the microstructure was examined, the analysis of the chemical composition and hardness using the Brinell method was made. It was found that the obtained microstructure of the alloys that we studied do not differ significantly. In all four samples, microscopic images were similar to each other. The volume, size and distribution of the phases remain similar. Analysis of the chemical composition showed that all the samples fall within the compositions provided for the test alloy. Further to this the hardness of the samples, regardless of the number of remeltings did not show any significant fluctuations and remained within the error limit. After analyzing all the results, it can be concluded that the remeltings of the alloys should not have a significant impact on their properties. Secondarily melted alloys can be used for prosthetics works.
Źródło:
Archives of Foundry Engineering; 2013, 13, 3; 47-50
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innowacyjne procesy druku 3D – analiza ryzyka wdrożenia innowacji w branży stomatologicznej
Autorzy:
Klimecka-Tatar, D.
Kapustka, K.
Powiązania:
https://bibliotekanauki.pl/articles/114772.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
innowacje
druk 3D
stomatologia
protetyka
analiza SWOT
stomatology
prosthetics
3D printing
SWOT analysis
Opis:
Branża medyczna jest oceniana jako jedna z bardziej nowoczesnych dziedzin gospodarki wymagających stosowania zaawansowanych technologii. Jednocześnie spełnienia wysokich oczekiwań społecznych dotyczących wprowadzania na rynek nowych sposób poprawiania stanu zdrowia pacjentów. Obecnie obserwuje się ciągły postęp w dziedzinie druku 3D, a możliwości aplikacyjne w przyszłości stworzą bardzo wartościowy rynek. Artykuł przedstawia analizę branży stomatologicznej, implementację nowoczesnego rozwiązania – druku 3D w wybranej klinice stomatologicznej, zapoznanie z systemami pracy drukarek 3D, macierz BCG do oceny możliwości rynkowych oraz przedsiębiorstwa, rozbudowaną analizę otoczenia SWOT oraz TOWS, kalkulację ceny produktu.
Źródło:
Zeszyty Naukowe. Quality. Production. Improvement; 2016, 1 (4); 92-106
2544-2813
Pojawia się w:
Zeszyty Naukowe. Quality. Production. Improvement
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doświadczanie ciała zrekonstruowanego protezą kończyny górnej – socjosomatyczne studium ciała biotechnologicznego
Autorzy:
Kowal, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/1373087.pdf
Data publikacji:
2018-09-11
Wydawca:
Uniwersytet Łódzki. Wydawnictwo Uniwersytetu Łódzkiego
Tematy:
ciało
doświadczanie ciała
ciało biotechnologiczne
technicyzacja cielesności
rekonstrukcja technologiczna ciała
protezowanie ciała
body
body experience
biotechnological body
technicality of corporeality
technological reconstruction of the body
body prosthetics
Opis:
Artykuł przyjmuje postać socjosomatycznego studium nad ciałem zrekonstruowanym protezą kończyny górnej. Jego podstawę empiryczną stanowią badania jakościowe przeprowadzone w grupie osób posiadających unilateralny lub bilateralny deficyt ręki (N=21), który w przypadku tej celowo dobranej grupy podlegał technologicznemu uzupełnieniu przy zastosowaniu zarówno protezy funkcjonalnej (mechanicznej bądź mioelektrycznej), jak i kosmetycznej. Zbieranie i analizowanie materiału empirycznego odbywało się zgodnie z założeniami i podstawowymi zasadami konstruktywistycznego ujęcia metodologii teorii ugruntowanej według Kathy Charmaz. W określeniu ramy teoretycznej sięgnięto do fenomenologii (Maurice Merleau-Ponty) oraz niektórych nurtów społecznego konstruktywizmu (Michael Foucault, Erving Goffman, Arthur Frank). Zasadniczą część tekstu stanowią analizy materiału empirycznego, które koncentrują się wokół problemu podmiotowego doświadczania ciała biotechnologicznego na płaszczyźnie podejmowanego działania w wymiarze: 1) funkcjonalnym, 2) estetycznym, 3) zmysłowym, 4) interakcyjnym, 5) tożsamościowym. Pracę wieńczą wnioski dotyczące waloru aplikacyjnego prezentowanych badań na gruncie medycyny klinicznej.
The paper has the form of a sociosomatic study of the body reconstructed with an upper limb prosthesis. Its empirical basis is a qualitative research carried out in a group of people with a unilateral or bilateral hand deficit (N=21), which in this purposefully selected sample has been technologically supplemented using either a functional (mechanical or myoelectric) or a cosmetic prosthesis. The empirical material has been gathered and analyzed in line with the assumptions and basic principles of the constructivist approach to grounded theory methodology according to Kathy Charmaz. The theoretical framework is based on phenomenology (Maurice Merleau-Ponty) and some trends in social constructivism (Michael Foucault, Erving Goffman, Arthur Frank). The main body of the paper contains analyses of empirical material focused on the issue of subjective experience of biotechnological body with regard to undertaken activities in the 1) functional, 2) aesthetic, 3) sensory, 4) interactive, 5) identity-related dimensions. The paper closes with conclusions concerning possible applications of the presented research in clinical medicine.
Źródło:
Przegląd Socjologii Jakościowej; 2018, 14, 3; 178-205
1733-8069
Pojawia się w:
Przegląd Socjologii Jakościowej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zestaw pomiarowy do badań diagnostycznych protez zębowych
Measuring system for diagnostics of dental prostheses
Autorzy:
Kuchta, M.
Kwiatos, K.
Fokow, K.
Powiązania:
https://bibliotekanauki.pl/articles/327460.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
protetyka stomatologiczna
diagnostyka
kinematyka protez
biomechanika stomatologiczna
system pomiarowy
dental prosthetics
diagnostics
dentures kinematics
dental biomechanics
measuring system
Opis:
Referat przedstawia metodę i układ pomiarowy do obiektywnej oceny jakości materiałów użytych do konstrukcji protez szczękowych jak również samej jej konstrukcji. Opracowany specjalizowany zestaw pomiarowy umożliwia wykonywanie szerokiego zakresu badań statycznych i dynamicznych, w ściśle określonych warunkach, na protezach zębowych.
The paper presents the method and measuring system for an objective assessment of materials used for the construction of prostheses and for the assessment of the constructions as well. The proposed system is capable of conducting wide range static and dynamic examinations of the prostheses.
Źródło:
Diagnostyka; 2006, 3(39); 187-192
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance and Microstructure of Recasting Cobalt Alloys Used in Dental Prosthetics
Autorzy:
Loch, J.
Krzykała, A.
Łukaszczyk, A.
Augustyn-Pieniążek, J.
Powiązania:
https://bibliotekanauki.pl/articles/380935.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
investment casting technology
ceramic moulds
dental prosthetics
cobalt alloys
corrosion resistance
technologia odlewania
formy ceramiczne
protetyka stomatologiczna
stopy kobaltu
odporność na korozję
Opis:
The work presents the results of the studies of Co-Cr-Mo casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo alloys of different contents of Mo, W and other additives. Electrochemical tests were performed, which aimed at examining the corrosion resistance of the alloys and observing the alloy structure after chronoamperometric tests with the potential in the area of the occurrence of the passive layer breakpoint. The alloy microstructure images after chronoamperometric tests show the presence of non-uniformly distributed general corrosion. Moreover, a project of cobalt alloy casting was elaborated using a ceramic mold casting. Additionally, analysis of the obtained microstructure was performed. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure.
Źródło:
Archives of Foundry Engineering; 2017, 17, 2; 63-68
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Remelting on the Quality of Prosthetic Cobalt Alloys
Autorzy:
Nadolski, M.
Łągiewka, M.
Konopka, Z.
Zyska, A.
Golański, G.
Powiązania:
https://bibliotekanauki.pl/articles/382647.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt alloy
centrifugal casting
lost wax technology
dental prosthetics
stop kobaltu
odlewanie odśrodkowe
metoda wytapianych modeli
protetyka stomatologiczna
Opis:
A commercial cobalt alloy applied in dental prosthetics was investigated. The scope of the work included the microstructure analysis, performance examination (tensile strength, microhardness, corrosion resistance), and dilatometric examination. The investigated alloy after a single remelting was characterised by higher tensile strength and hardness. There were not found the definite results with regard to the corrosion resistance of the examined materials. No significant change occurred in the coefficient of thermal expansion.
Źródło:
Archives of Foundry Engineering; 2015, 15, 3 spec.; 53-58
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies