Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "prosthetic construction" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Identification of the cause of the stem neck fracture in the hip joint endoprosthesis
Autorzy:
Ryniewicz, A. M.
Bojko, Ł.
Ryniewicz, A.
Pałka, P.
Ryniewicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/265412.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
proteza plastyczna
złamanie zmęczeniowe
metoda elementów skończonych
skaningowa mikroskopia elektronowa
prosthetic arthroplasty
stem construction
fatigue fracture
FEM
SEM (scanning electron microscopy)
Opis:
Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed indicate that the most probable causes leading to the fatigue fracture of the Aura II stem under examination were material defects in the process of casting and forging (forging the material with delamination and the presence of brittle oxides and carbides) that resulted in a significant reduction of strength and resistance to corrosion. In the light of an unprecedented stem neck fracture, this information should be an indication for non-destructive tests of ready-made stems aiming to discover the material and technological defects that may arise in the process of casting and drop forging.
Źródło:
International Journal of Applied Mechanics and Engineering; 2018, 23, 1; 223-234
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of surface microgeometry and structure of layered biomaterials used for prosthetic constructions in digital technologies
Analiza mikrogeometrii powierzchni i struktury biomateriałów warstwowych stosowanych na konstrukcje protetyczne w technologiach cyfrowych
Autorzy:
Ryniewicz, Wojciech
Ryniewicz, Anna M.
Bojko, Łukasz
Leszczyńska-Madej, Beata
Ryniewicz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/189984.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
prosthetic construction
substructure
veneering layer
microgeometry
structure
roughness
konstrukcja protetyczna
podbudowa
warstwa licująca
mikrogeometria
struktura
chropowatość
Opis:
Veneering layers of prosthetic substructures are responsible for tribological cooperation with opposite teeth in the stomatognathic system (SS). Investigations of microgeometry and structure of veneering layers are aimed at checking to what extent these layers replicate enamel parameters, which, under complex load conditions, are characterized by the phenomenon of resistance to tribological wear. Ceramic veneering layers are dedicated for substructures made in digital technologies from factory fittings by milling and laser sintering of metal powders. Using a confocal microscope, contactless tests of the surface layer stereometry were performed and surface roughness parameters were determined on samples of ceramics veneering of prosthetic substructures. The analysis was performed in comparison to the natural enamel of premolars and molars. The shaping of the surface of materials veneering the substructures is similar to the regularity determined in the statistical analysis of the enamel roughness. Layers facing samples from milling technology are characterized by lower values of roughness parameters than layers created on substructures made of SLM technology.
Warstwy licujące podbudowy protetyczne są odpowiedzialne za współpracę tribologiczną z zębami przeciwstawnymi w układzie stomatognatycznym (US). Badania mikrogeometrii i struktury warstw licujących mają na celu sprawdzenie, w jakim stopniu warstwy te replikują parametry szkliwa, które w złożonych warunkach obciążeń charakteryzuje się fenomenem odporności na zużycie tribologiczne. Materiałem badań są ceramiczne warstwy licujące dedykowane na podbudowy wykonane w technologiach cyfrowych: z fabrycznych kształtek metodą frezowania oraz technologią spiekania laserowego z proszków metali. Z wykorzystaniem mikroskopu konfokalnego wykonano bezstykowe badania stereometrii warstwy wierzchniej oraz wyznaczono parametry chropowatości powierzchni na próbkach ceramik licujących podbudowy protetyczne. Analizę przeprowadzono w porównaniu ze szkliwem naturalnym zębów przedtrzonowych i trzonowych. Ukształtowanie powierzchni materiałów licujących podbudowy w różnym stopniu zbliża się do regularności wyznaczonej w statystycznej analizie chropowatości szkliwa. Warstwy licujące próbki z technologii frezowania charakteryzują się niższymi wartościami parametrów chropowatości niż warstwy utworzone na podbudowach z technologii SLM.
Źródło:
Tribologia; 2019, 287, 5; 101-113
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies