Tytuł:
New concept in durability improvement of hip total joint endoprostheses
Autorzy:
Capitanu, L.
Florescu, V.
Badita, L.L.
Powiązania:
https://bibliotekanauki.pl/articles/951796.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
total hip prostheses
rolling bodies
MOM prostheses
self-directed movement
endoproteza stawu biodrowego
biomateriały
samoprzemieszczanie
zużycie materiału
Opis:
Starting from the well-known fact that the rolling movement always has a lower friction compared to sliding friction, the authors have conceived and realized a pivoting movement joint on a “layer of balls” with “compensation space”, placed between the acetabular cup and the femoral head. This technical solution allows free self-directed migration of the balls, depending on the resistance opposed, with successive occupation of the “compensation space”. As a concept, the proposed technical solution excludes the existence of a cage for maintaining the relative positions of the spheres. It can be observed that the smallest values of the force and of the friction coefficient are obtained for the prostheses with balls and self-directed movement (approximately 5 times smaller than the values obtained for a classical prosthesis). For all the couples tested, the friction force grows with the growth of the normal load and of the oscillation speed. Changing the contact mechanism for the artificial hip joint from one sliding contact between two large surfaces, to a multitude of rolling contacts, could lead to some problems regarding functionality and durability of the active prosthesis elements. The key to an accurate evaluation of damaging mechanisms acting on THP with self directed rolling balls is a clear and complete picture of the load transfer mechanism.
Źródło:
Acta of Bioengineering and Biomechanics; 2014, 16, 1; 75-82
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Consciousness, Culture, and the Brain
Autorzy:
Bartra, Roger
Powiązania:
https://bibliotekanauki.pl/articles/451381.pdf
Data publikacji:
2018-07-18
Wydawca:
Uniwersytet Warszawski. Wydział Filozofii
Tematy:
exocerebrum
brain
consciousness
symbolic prostheses
philosophy of mind
Opis:
Human consciousness is a phenomenon that occurs not only in the brain but also in an external network, a symbolic system. This symbolic system is defined as an exocerebrum. The exocerebrum is a system of artificial cultural prostheses that substitute functions the brain cannot carry out through exclusively biological means. The exocerebrum is a symbolic system that substitutes the cerebral circuits that are incapable by themselves of completing functions that are characteristic of human mental behavior. The brain is not capable of processing symbols without the help of an external system essentially made up of speech, symbols, the non-discursive forms of communication (such as music, dance, and painting), and the exterior artificial memories (from writing to the Internet). We are in the presence of a continual spectrum, one in which there is no need to draw a dividing line between the brain and the exocerebrum, between the neuronal circuits and the cultural prostheses.
Źródło:
Eidos. A Journal for Philosophy of Culture; 2018, 2, 2(4); 100-114
2544-302X
Pojawia się w:
Eidos. A Journal for Philosophy of Culture
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wiązanie jonowe cyprofloksacyny na różnych typach protez naczyniowych
Ionic ciprofloxacin binding to different types of vascular prostheses
Autorzy:
Osińska-Jaroszuk, M.
Ginalska, G.
Powiązania:
https://bibliotekanauki.pl/articles/284460.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
protezy naczyniowe
cyprofloksacyna
biomateriały
vascular prostheses
ciprofloxacin
biomaterials
Źródło:
Engineering of Biomaterials; 2008, 11, no. 77-80; 23-24
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrostruktura i właściwości niskotarciowej nanokompozytowej powłoki nc-TiC/a-C na utwardzonym tlenem stopie Ti-6Al-7Nb
Microstructure and properties of low friction nanocomposite nc-TiC/a-C coating on Ti-6Al-7Nb alloy
Autorzy:
Moskalewicz, M.
Wendler, B.
Zimowski, S.
Czyrska-Filemonowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/284418.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy tytanu
endoprotezy
mikrostruktura
titanium alloys
joint prostheses
microstructure
Opis:
W pracy przedstawiono charakterystykę mikro/nanostruktury, właściwości mikro-mechanicznych i tribologicznych powłoki nc-TiC/a-C osadzonej na utwardzonym powierzchniowo atomami tlenu stopie Ti-6Al-7Nb. Badania mikro/nanostruktury przeprowadzono za pomocą skaningowej i transmisyjnej mikroskopii elektronowej na próbkach z przekroju poprzecznego. Stwierdzono, że powłoka nc-TiC/a-C zbudowana jest z nanokrystalicznych cząstek TiC w amorficznej osnowie węgla. W warstwie wierzchniej utwardzonego tlenem stopu występował roztwór stały tlenu w tytanie α(O). Zastosowana obróbka powierzchniowa istotnie poprawiła mikrotwardość oraz właściwości tribologiczne stopu Ti-6Al-7Nb (wzrost odporności na zużycie przez tarcie, zmniejszenie współczynnika tarcia).
The microstructure as well as micro-mechanical and tribological properties of the nc-TiC/a-C coating deposited on oxygen hardened Ti-6Al-7Nb alloy were examined. Scanning- and transmission electron microscopy investigations on cross-section specimens were used for determination of microstructure and phase composition. It was found that the nc-TiC/a-C coating is composed of TiC nanocrystals embedded in an amorphous carbon matrix. The Ti α(O) solid solution enriched by interstitial oxygen atoms was mainly present in the near-surface region. A particular preliminary surface treatment of specimens significantly improved microhardness and final tribological properties: it increased wear resistance and decreased friction coefficient of the alloy against alumina bearing ball dry ball-on-disc sliding tests.
Źródło:
Engineering of Biomaterials; 2010, 13, no. 99-101; 42-44
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of Return Electrode Position on Induced Electric Fields for Electrical Stimulation of Retinal Ganglion Cells
Autorzy:
Celik, M.
Powiązania:
https://bibliotekanauki.pl/articles/1031744.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
electrical stimulation
electric field
current density
temperature
retina
visual prostheses
Opis:
Age-related macular degeneration and retinitis pigmentosa are the most countered eye diseases that damage photoreceptors and cause to lose the visual sense. To regain the visual sense, studies are focused on the electrical stimulation of nerve cells remain intact. The electrical stimulation is carried out with the electrode arrays that include a certain number of stimulation electrodes and a common return electrode. In this study, the retinal stimulation is modelled using a computational model to investigate stimulation performance depending on the return electrode position and its geometrical properties. Stimulation induced electric field, current density and temperature over the retinal tissue are examined. It is seen that closer placement of return electrode and stimulation electrodes causes high electric field intensity and current density between electrodes, which is quite risky for long term chronic implementation by the reason of the increase in the temperature beyond the safe limits. It is concluded that there is an indispensability for the distances, three to five times of the electrode diameter, between electrodes to avoid electrode corrosion and tissue damage.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 493-495
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie hydrożeli z ludzkiej albuminy jako powłoki uszczelniające protezy naczyniowe
Application of hydrogels composed of human serum albumin for dacron vascular graft sealing
Autorzy:
Szulc, A.
Walenko, K.
Lewandowska-Szumieł, M.
Ciach, T.
Powiązania:
https://bibliotekanauki.pl/articles/284018.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
hydrożele
protezy naczyniowe
albumina ludzka
hydrogels
vascular prostheses
human serum albumin
Źródło:
Engineering of Biomaterials; 2010, 13, no. 99-101; 51-53
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Protezy twarzy - aspekty medyczne i technologiczne
Medical and technological aspects of facial prostheses
Autorzy:
Matraszek, H.
Stodolak, E.
Błażewicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/285659.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
zabiegi onkologiczne
rehabilitacja protetyczna
protezy pooperacyjne
oncology treatment
prosthetic rehabilitation
post-surgical prostheses
Opis:
Badania kliniczne i ankietowe wykazały, iż pacjenci z uszkodzeniem twarzoczaszki, u których zalecano stosowanie endoprotez, w pierwszej kolejności decydowali się na umocowanie protezy zewnętrznej (ektoprotezy) za pomocą klejów medycznych, jako sposobu bardziej naturalnego i praktycznego. Obserwacje wykazały, że taki sposób połączenia korzystny ze względów praktycznych i psychofizycznych dla pacjenta jest problematyczny ze względu na nietrwałość połączenia pomiędzy skórą a implantem protetycznym. Kilkuletnie obserwacje wykazały, iż przy dłuższym okresie użytkowania np. ektoproteza oka połączona trwale z oprawkami okularów zapewnia trwalsze, pewniejsze połączenie, niż jakiekolwiek kleje medyczne. Celem pracy była wstępna charakterystyka zarówno materiałów silikonowych stosowanych na ektoprotezy (zwilżalność, en. powierzchniowa, parametry mechaniczne) jak i oszacowanie siły złącza adhezyjnego materiałów silikonowych przyklejonych do podłoża za pomocą środków komercyjnych (klejów i taśm obustronnych). Badania wykazały, że zbyt niska przyczepność (adhezja) środków klejących do materiałów silikonowych jest przyczyną nietrwałego połączenia ektoproteza-podłoże. Badania mają charakter wstępny, przygotowujący dalszą pracę nad próbami poprawy mocowania ektoprotezy.
Clinical tests and surveys showed that patients with craniofacial injuries for whom use of ecto-prostheses (external prostheses) was recommended preferred to fasten them with medical glues. It seems to be natural, practical and usefule for patients. Observations revealed that this way of the prosthesis fastening, although favourable for a patient from practical and psychophysical reasons. The most popular problem with ectoprosthesis is instability bonding between the prosthesis implant and skin. Several years of observations revealed, that long-term use of for example eye ecto-prosthesis permanently fixed to a spectacle frame provides durable, more reliable fastening that any medical glues. Aim of the work was a preliminary characteristics (wetability, surface energy, mechanical parameters) of silicone materials used for eco-prostheses and estimation of strength of adhesive connection between the silicone materials and substrate fastened with commercial media (glues, and typical technical adhesive tapes). The investigations showed that too low adherence of the adhesive media to the silicone materials is the reason to unstable connection between substrate and the prosthesis. The studies had only preliminary character, but they should enable further work at improvement of the ectoprosthesis fastening.
Źródło:
Engineering of Biomaterials; 2007, 10, no. 69-72; 118-121
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Algorytmy synchronizacji obciążeń na stanowisku do badań trybologicznych endoprotez stawu biodrowego
Synchronisation algorithms for tribological tests of hip-joint prostheses
Autorzy:
Bartyś, M.
Powiązania:
https://bibliotekanauki.pl/articles/153911.pdf
Data publikacji:
2002
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
algorytmy synchronizacji
stanowisko do badań trybologicznych
endoprotezy stawu biodrowego
Synchronisations algorithms
tribological tests of hip-joint prostheses
Opis:
W artykule przedstawiono problem synchronizacji obciążeń w wielosekcyjnym stanowisku do badań właściwości trybologicznych endoprotez stawu biodrowego. Podano trzy zweryfikowane eksperymentalnie algorytmy synchronizacji oraz omówiono ich właściwości.
In the paper the experimentally verified algorithms for bi-directional hip-joint prostheses loading synchronisation are presented. The algorithms are designed particularly for implementing in control unit of multi-sectional laboratory set-up for hip-joint wear and fatigue tests. The discussion of presented algorithms was given.
Źródło:
Pomiary Automatyka Kontrola; 2002, R. 48, nr 10, 10; 14-17
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Immediate prosthesis fitting and comprehensive rehabilitation following lower limb amputation – the most important components of physiotherapy
Szybkie protezowanie i kompleksowa rehabilitacja po amputacji kończyn dolnych – najważniejsze składniki postępowania fizjoterapeutycznego
Autorzy:
Pirowska, Aneta
Włoch, Tomasz
Nowobilski, Roman
Powiązania:
https://bibliotekanauki.pl/articles/1935829.pdf
Data publikacji:
2006
Wydawca:
Akademia Wychowania Fizycznego im. Bronisława Czecha w Krakowie
Tematy:
amputations
Prosthesis Fitting
physiotherapy
stump care
bandaging
prostheses
integration
Amputacje
protezowanie
fizjoterapia
pielęgnacja kikuta
bandażowanie
protezy
integracja
Opis:
In this paper, a model of rehabilitation and immediate prosthesis fitting following lower limb amputation was presented. Advantages of amputee’s treatment in a specialised centre for comprehensive rehabilitation, beginning with the first days of hospitalisation up to the point of achievement of optimal physical fitness and independence allowing hospital discharge, were emphasised. Psychological support offered to the patients was addressed. Peculiar character of physiotherapist’s range of activity both in patients’ rehabilitation and prosthesis fitting was presented. The role of early prosthesis application was emphasised by presenting successive stages of fabrication of the temporary and then the definitive prosthesis, from taking the measure, formation of stump positive and, subsequently, of particular components of the prosthesis, up to its regulation, definitive assembly of all parts and finishing. Examples of prosthetic solutions for instrumentation of irregularly shaped stumps were described and shown. The essence of correct stump positioning for preventing contractures as well as its bandaging to combat post-operation oedema, to reduce pain, accelerate post-surgery wound healing and stump formation was denoted. Successive stages of patient’s mobilisation, assuming the erect posture and gait learning, including walking on a stairway, uneven ground and overcoming obstacles, as well as types of the performed kinesitherapeutic exercises and most frequently used physiotherapeutic procedures were distinguished. Forms of sport-recreational treatment and integration activities aiming at patient’s best possible preparation for independent life were discussed. Additionally, the spectrum of ergotherapist’s activities, including patient home visits to adjust household conditions to new patient’s needs, was presented. Finally, based on a case report of a patient in advanced age with prolonged stump healing, the whole process of immediate prosthetic fitting and comprehensive rehabilitation, starting with the day of admission to the rehabilitation centre up to the point of definitive application of the prosthesis and achievement of complete independence, was described.
W pracy przedstawiono model rehabilitacji i szybkiego protezowania po amputacji kończyn dolnych. Wskazano zalety prowadzenia usprawniania chorego po amputacji w wyspecjalizowanym ośrodku kompleksowej rehabilitacji, począwszy od pierwszych dni hospitalizacji, aż do momentu uzyskania optymalnej sprawności fizycznej i samodzielności, pozwalających na jego opuszczenie. Uwzględniono oferowane pacjentom wsparcie psychologiczne. Przedstawiona została specyfika zakresu działań fizjoterapeuty zarówno w rehabilitacji, jak i protezowaniu pacjentów. Wskazano rolę wczesnego protezowania, prezentując kolejne etapy powstawania protezy tymczasowej, a później definitywnej, począwszy od pobrania miary, wykonania pozytywu kikuta, a następnie poszczególnych elementów protezy, aż do zakończenia jej regulacji, połączenia definitywnego wszystkich jej części i wykończenia. Opisane i pokazane zostały przykładowe rozwiązania protetyczne dla zaaparatowania kikuta o nieregularnym kształcie. Zaznaczono istotę prawidłowego układania kikuta w profilaktyce przeciw powstawaniu przykurczy, oraz jego bandażowania, w walce z obrzękiem pooperacyjnym, w celu ograniczenia dolegliwości bólowych, przyspieszenia gojenia się rany pooperacyjnej i formowania kikuta. Wyszczególnione zostały kolejne etapy uruchamiania pacjenta, pionizacji i nauki chodu, wraz z poruszaniem się po schodach, nierównym podłożu i pokonywaniem przeszkód oraz rodzaje wykonywanych ćwiczeń kinezyterapeutycznych i najczęściej stosowanych zabiegów fizykoterapeutycznych. Omówiono formy prowadzonych z pacjentami zajęć aktywności sportowo-rekreacyjnej i działań integracyjnych, mających na celu jak najlepsze przygotowanie pacjenta do samodzielnego życia. Dodatkowo przedstawiony został zakres działań ergoterapeuty, z uwzględnieniem przeprowadzanych przez niego wizyt w domu pacjenta, w celu przystosowania warunków mieszkaniowych do nowych potrzeb chorego. Na końcu, na przykładzie opisu przypadku pacjenta w zaawansowanym wieku, z długo gojącym się kikutem, pokazano cały proces szybkiego protezowania i kompleksowej rehabilitacji od dnia przyjęcia do ośrodka rehabilitacji aż do momentu definitywnego zaprotezowania. i uzyskania pełnej samodzielności.
Źródło:
Medical Rehabilitation; 2006, 10(1); 9-26
1427-9622
1896-3250
Pojawia się w:
Medical Rehabilitation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Penicylina i protezy. Pomoc UNRRA w odbudowie polskiego przemysłu medycznego po drugiej wojnie światowej
Penicillin and prostheses. UNRRA’s help in rehabilitating Poland’s medical industries after World War II
Autorzy:
Łotysz, Sławomir
Powiązania:
https://bibliotekanauki.pl/articles/1853569.pdf
Data publikacji:
2018
Wydawca:
Narodowe Centrum Kultury
Tematy:
unrra
odbudowa powojenna
przemysł farmaceutyczny
inwalidzi wojenni
protezy
niepełnosprawność
post-war reconstruction
pharmaceutical industry
war veterans
prostheses
disability
Opis:
When World War II came to an end, the United Nations Relief and Rehabilitation Administration (UNRRA) offered substantial aid to many countries, including Poland. It provided food, medicine and clothing to millions of war victims, and also provided ‘help to self-help’ the nations as a whole, by assisting local government entities in reconstructing industry, agriculture, and transportation infrastructure in the war-torn countries. For example, a penicillin factory and a prosthetic production facility were built in Poland as part of the UNRRA program. This paper draws a comparison between disabled veterans and the early postwar states. The latter, also significantly affected by the war, had to be similarly aided and rehabilitated in order to regain their ability to perform their everyday duties. The article sheds light on how the artificial limb plant program was negotiated to meet the needs of Poland and its war veterans. .
Źródło:
Kultura Współczesna. Teoria. Interpretacje. Praktyka; 2018, 102, 3; 118-130
1230-4808
Pojawia się w:
Kultura Współczesna. Teoria. Interpretacje. Praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computational simulation analysis for torus radius of edge contact in hip prostheses
Autorzy:
Li, F.
Chen, H
Mao, K.
Powiązania:
https://bibliotekanauki.pl/articles/307414.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw biodrowy
endoproteza
kontakt Hertza
nacisk kontaktowy
hip prostheses
Hertzian contact
edge torus radius
contact pressure
contact dimensions
inclination angle
Opis:
Stripe wear occurs when the components of hip prostheses move a sufficient distance laterally to contact the edge of the acetabular cup, causing abnormally high contact stresses. In this research, edge loading contact of prosthetic hip is analyzed in the most commonly used material pairs. The contact dimensions and maximal contact pressure are investigated in mutative normal edge loading with 3 different inclination angles (15°, 20°, 25°) and in alterable edge torus radius with edge loading of 2500 N and inclination of 20°. A computational case was conducted for a 14 mm radius alumina ceramic bearing with a radial clearance of 0.1 mm using a normal edge loading ranged from 0 N to 3000 N. Additionally, the Hertzian theory successfully captures principal curvature trends of the edge torus on the influence of maximal contact pressure and obtains the appropriate edge radius range for lower maximal contact pressure. This work elucidates the methods of applying classical contact theory to design the edge radius of hip bearings to better resist severe edge loading contact stresses and reduce the stripe wear.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 3; 67-73
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling and Analysis of the Circumferential Forces and Susceptibility of Vascular Prostheses to Internal Pressure Changes
Modelowanie i analiza sił obwodowych i podatności obwodowej protez naczyń krwionośnych na zmiany ciśnienia wewnętrznego
Autorzy:
Kowalski, K.
Mielicka, E.
Jasińska, I.
Powiązania:
https://bibliotekanauki.pl/articles/231875.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
trykot
protezy naczyniowe
prawo Laplace'a
siły obwodowe
średnia podatność obwodowa
podatność obwodowa
knitted fabric
vascular prostheses
Laplace's low
pressure
circumferential
susceptibility
circumferential forces
standard circumferential susceptibility
Opis:
Based on Laplace's law and the mechanical characteristics of knitted vascular prostheses, mathematical models have been developed enabling one to determine the values of the relative circumferential elongation, circumferential forces and standard circumferential susceptibility of a prosthesis as a function of its diameter and internal pressure. The results obtained refer to the values of the parameters assessed for the initial phase of their exploitation, allow to preliminarily predict the values of these parameters.
Na podstawie prawa Laplace'a i charakterystyki mechanicznej dzianiny stosowanej do wytwarzania protez naczyń krwionośnych opracowano modele matematyczne umożliwiające wyznaczenie wartości obwodowego wydłużenia względnego, sił obwodowych i normatywnej podatności obwodowej w funkcji średnicy protezy i ciśnienia wewnętrznego. Wyniki uzyskane z tych analiz odnoszą się do wartości ocenianych parametrów dla początkowej fazy ich eksploatacji i pozwolą one na wstępne prognozowanie wartości tych parametrów.
Źródło:
Fibres & Textiles in Eastern Europe; 2012, 3 (92); 87-91
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Endothelial cells on pet vascular prostheses impregnated with polyester-based copolymers and coated with cell-adhesive protein assemblies
Autorzy:
Chlupac, J.
Filova, E.
Riedel, T.
Brynda, E.
Pamuła, E.
Lisa, V.
Bacakova, L.
Powiązania:
https://bibliotekanauki.pl/articles/284406.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
vascular prostheses
polyethylene terephtalate
poly(glycolide-L-lactide)
poly(glycolide-L-lactide-(ε)caprolactone)
extracellular matrix
surface modification
collagen
laminin
fibronectin
fibrin
endothelial cells
static cell culture
Opis:
Arterial bypass surgery with synthetic vascular prostheses achieves poor patency rates compared to autogenous natural materials, and this is a challenge for tissue engineering research concerning small caliber vascular grafts. Modifications of the prosthetic surface followed by endothelial cell seeding may reduce thrombogenicity and intimal hyperplasia. Planar polyethylene terephthalate (PET) vascular prosthetic samples were impregnated with the copolymer poly(glycolide-L-lactide) (PGL) or with the terpolymer poly(glycolide-L-lactide-(e)caprolactone) (PGLCap) in order to lower the permeability of the knitted fabrics and ensure a less adhesive background. Subsequent modification with adhesive protein assemblies composed of collagen type I (Co) in conjunction with laminin (LM), fibronectin (FN) or fibrin (Fb) gel was performed to enhance cell adhesion. Bovine pulmonary artery endothelial cells (EC) of the CPAE line were seeded on to the coatings and subjected to static tissue culture conditions for 7 days. Impregnation of the PET prostheses decreased the initial adhesion and proliferation of the EC. After coating with the protein assemblies, the impregnated PET provided better substrates for cell culture than the protein-coated PET, on which the EC population started decreasing after 4 days of culture. The cells proliferated better on the CoFN, CoFb and CoFbFN coatings than on the Co and CoLM coatings. Impregnation type and adhesive matrix protein deposition may play an important role in successful endothelialization, healing and clinical performance of vascular grafts.
Źródło:
Engineering of Biomaterials; 2008, 11, no. 81-84; 108-111
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Polymers in medicine – direction of development
Polimery w medycynie – kierunki rozwoju
Autorzy:
Dworak, Andrzej
Utrata-Wesołek, Alicja
Otulakowski, Łukasz
Kasprów, Maciej
Trzebicka, Barbara
Powiązania:
https://bibliotekanauki.pl/articles/947555.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
polymeric materials in medicine
intelligent materials
drug carriers
vascular stents
vascular prostheses
orthopedic implants
tissue culture substrates
antifouling layers
materiały polimerowe w medycynie
materiały inteligentne
nośniki leków
stenty
protezy naczyniowe
implanty ortopedyczne
podłoża do hodowli tkanek
warstwy przeciwporostowe
Opis:
The paper constitutes a brief and subjective review of polymeric materials in the contemporary health service. The range of applications of polymeric materials is discussed, special att ention being paid to such materials for the development of carriers of pharmaceutically active species, stents and vascular prostheses, amongst them to the application of „smart” materials for these purposes, layers and scaff olds for the growth of organs and tissues, antifouling layers. The authors try to turn the att ention of the reader to the research and intellectual eff orts necessary for the development of polymeric materials for the medicine, and conclude about the growing importance of such studies.
Artykuł stanowi skrótowy, subiektywny przegląd materiałów polimerowych wykorzystywanych we współczesnej ochronie zdrowia. W pracy skupiono się na zastosowaniach materiałów polimerowych do konstrukcji nośników leków, stentów i protez naczyń, w tym także na użyciu polimerowych materiałów „inteligentnych”, implantów ortopedycznych oraz podłoży i rusztowań do hodowli komórek lub tkanek, a także warstw zapobiegających porastaniu wszczepionych konstruktów. Autorzy zwracają uwagę na znaczny wysiłek badawczy i intelektualny, niezbędny w procesie opracowania materiałów polimerowych dla medycyny, i na stale rosnące znaczenie takich badań.
Źródło:
Polimery; 2019, 64, 10; 645-655
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies